• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Études expérimentales de dispositifs intégrés à base de micro-résonateurs à mode de galerie en verres actifs / Experimental studies of integrated devices based on whispering gallery mode micro-resonators in active glasses

Rasoloniaina, Alphonse 14 February 2014 (has links)
Les microrésonateurs à mode de galerie passifs à base de cristal ou de verre fabriqués par la méthode de fusion possèdent un facteur de qualité limité à quelques 10E8. Ceci est généralement dû à la contamination de la surface du résonateur lors de sa fusion. Dans ces travaux, nous proposons de contourner cette limitation en utilisant des microrésonateurs actifs pour compenser les pertes. Afin de caractériser les microrésonateurs actifs de très haut facteur de qualité ainsi obtenu, nous nous appuyons sur la méthode CRDM (Cavity Ring Down Measurement). Cette méthode interférométrique est d'une part bien adaptée à la caractérisation de résonateurs de très haut facteur de qualité et d'autre part elle permet de remonter de manière univoque aux facteurs de qualité intrinsèque Qo et extrinsèque Qe du résonateur. Dans un régime de compensation de pertes, nous avons pu atteindre tous les régimes de couplage et obtenus des facteurs de qualité intrinsèques excédant les 10E10. En régime d'amplification sélective, nous avons démontré expérimentalement que l'on pouvait obtenir des gains élevés allant jusqu'à 33 dB et des retards de groupe excédant 2,3 µs dans ces microrésonateurs actifs. Ces microrésonateurs de très haut facteur de qualité et de très haute finesse peuvent présenter un couplage modal se manifestant par un doublet de résonances. Une confrontation théorie/expérience avec la méthode CRDM permet de mesurer un écart très faible entre les doublets. Par ailleurs, ces microrésonateurs présentant un fort confinement spatial et une forte surtension, sont propices à l'observation d'effets non-linéaires. Une modélisation intégrant l'effet thermique et l'effet Kerr a été réalisée. Une confrontation théorie/expérience nous a permis d'estimer la puissance réellement injectée dans le mode ainsi qu'à estimer le volume du mode. / Glass-based whispering gallery mode (WGM) microresonators are easy to produce by melting techniques. However, they suffer from surface contamination which limits their long term quality factor to only about 10E8. In this thesis, we show that an optical gain provided by erbium ions can compensate for residual losses. The optical characterization method is based on frequency-swept “Cavity-Ring-Down-Measurement”. This method can fully describe the linear properties of microcavities such as coupling regime and group delay. In compensation loss regime we demonstrate that it is possible to control the coupling regime of an ultrahigh Q-factor microresonator from undercoupling to spectral selective amplification. Under the selective amplification regime, we obtain an internal Q-factor exceding 10E10. In selective amplification, we experimentally show that it is possible to obtain high amplification up to 33 dB and a high group delay. The microresonators with high Q-factor and high finesse could give rise to a modal coupling which exhibits a splitting of the resonance in the transmission. A characterization of this phenomenon with the cavity ring down method was realized. Moreover, these microresonators, are conducive to the non-linear effect observation. A model incorporating the thermal effect and the Kerr effect has been achieved. Confrontation between theory and experiment allowed us to estimate the real optical power injected into the mode as well as estimating the mode volume.
2

Etude du couplage optomécanique dans une cavité de grande finesse. Observation du mouvement Brownien d'un miroir

Hadjar, Yassine 25 November 1998 (has links) (PDF)
The topic of this thesis is the theoretical analysis of theoptomechanical coupling effects in a high-finesse optical cavity, and the experimental realization of such a device.Radiation pressure exerted by light limits the sensitivity of high precision optical measurements. In particular, the sensitivity of interferometric measurements of gravitational wave is limited by the so called standard quantum limit. cavity with a movable mirror. The internal field stored in such cavity can be orders of magnitude greater than the input field, and it's radiation pressure force can change the physical length of the cavity. In turn, any change in the mirror's position changes the phase of the out put field. This optomechanical coupling leads to an intensity-dependent phase shift for thelight equivalent to an optical Kerr effect. Such a device can then be used for squeezing generation or quantum nondemolition measurements.In our experiment, we send a laser beam in to a high-finesse optical cavity with a movable mirror coated on a high Q-factor mechanical resonator. Quantum effects of radiation pressure become therefore, at low temperature, experimentally observable. However, we've shown that the phase of the reflected field is very sensitive to small mirror displacements, which indicate other possible applications of thistype of device like high precision displacements measurements. We've been able to observe the Brownian motion of the moving mirror. We've also used an auxiliary intensity modulated laser beam to optically excite the acoustic modes. We've finally obtained a sensitivity of2x10^(-19) m/sqrt(Hz), in agreement with theoretical prediction.
3

Spectroscopie Laser avec des cavités résonantes de haute finesse couplées à un peigne de fréquences : ML-CEAS et vernier effet techniques. Applications à la mesure in situ de molécules réactives dans les domaines UV et visible. / Cavity enhanced multiplexed comb spectroscopy : ML-CEAS and Vernier effect techniques Application : a UV Spectrometer for in situ measurements of reactive molecules.

Abd Alrahman, Chadi 25 October 2012 (has links)
La communauté de la chimie atmosphérique souffre d'un manque de mesures rapides, fiables résolues spatialement et temporellement pour un large éventail de molécules réactives (radicaux tels que NO2, OH, BrO, IO, etc). En raison de leur forte réactivité, ces molécules contrôlent largement la durée de vie et la concentration de nombreuses espèces clés dans l'atmosphère, et peuvent avoir un impact important sur le climat. Les concentrations de ces radicaux sont extrêmement faibles (ppbv ou moins) et très variable dans le temps et dans l'espace, ce qui impose un véritable défi lors de la détection. Dans la première partie de cette thèse, un spectromètre UV robuste, compacte et transportable est développé, exploitant la technique ML-CEAS pour mesurer à des niveaux très faibles (pptv et même en dessous) des molécules réactives d'importance atmosphérique, en particulier, les radicaux d'oxyde d'halogènes, afin de répondre aux besoins émergents. La technique ML-CEAS est basée sur le couplage d'un laser femtoseconde à blocage de modes à une cavité optique de haute finesse, qui agit comme un piège à photons pour augmenter l'interaction entre la lumière et l'échantillon de gaz intracavité. Cela permet d'améliorer fortement la sensibilité d'absorption. La limite de détection obtenue pour le radical IO est de 20 ppqv pour un temps d'acquisition de 5 minutes, ce qui est un résultat impressionnant. Dans la deuxième partie de cette thèse, une nouvelle technique spectroscopique est développée appelée effet Vernier, qui est également basé sur l'interaction entre un laser femtoseconde à blocage de mode et une cavité optique de haute finesse. Cette technique fournit une sensibilité de détection similaire à la technique ML-CEAS, mais l'avantage est que le nombre des éléments spectraux est donné par la finesse de la cavité optique et donc peut atteindre plusieurs dizaines de milliers. De plus, cette configuration simplifie le montage expérimental par la suppression du spectrographe qui est remplacé par une simple photodiode. Le temps d'acquisition d'un spectre peut être aussi réduit à moins d' 1 ms. / The atmospheric chemistry community suffers a lack of fast, reliable and space resolved measurements for a wide set of reactive molecules (e.g. radicals such as OH, NO3, BrO, IO, etc). Due to their high reactivity, these molecules largely control the lifetime and concentration of numerous key atmospheric species, and may have an important impact on the climate. The concentrations of such radicals are extremely low (ppbv or less) and highly variable in time and space, which imposes a real challenge during the detection. In the first part of this thesis, a compact, robust and transportable UV spectrometer is developed, exploiting the Mode-Locked Cavity Enhanced Absorption Spectroscopy (ML-CEAS) technique to measure pptv and sub-pptv levels of atmospherically important reactive molecules, in particular, halogen oxide radicals, to respond to the emerging needs. The ML-CEAS technique is based on coupling a Mode-Locked femtosecond laser to a high finesse optical cavity, which acts as a photon trap to increase the interaction between the light and the intracavity gas sample, which highly enhances the absorption sensitivity. The detection limit obtained for the IO radical is 20 ppqv (part per quadrillion), which is an impressive result. In the second part of this thesis, a new spectroscopic technique is developed, called Vernier effect, which is also based on the interaction between a mode-locked femtosecond laser with a high finesse optical cavity. This technique provides detection sensitivity similar to that of ML-CEAS technique, but the advantage is that the number of the spectral elements is given by the cavity finesse, so it can reach ten thousands, as well as this technique has a simple setup, where the spectrograph is replaced by a photodiode. Additionally, the time required to measure one output absorption spectrum can be less than 1 ms.
4

Maintien du couplage optique entre une ECDL et une cavité de haute finesse : application à la mesure ultrasensible de biréfringence induite par effet Kerr / Maintenance of the optical coupling between an External Cavity Diode Laser and a high finesse cavity : application to ultrasensitive measurement of birefringence induced by Kerr effect

Durand, Mathieu 23 July 2009 (has links)
Ce travail se place dans le cadre de la mesure ultrasensible d’anisotropie de phase optique que permet l’emploi adapté des cavités de très haute finesse. Pour stabiliser la fréquence laser sur une résonance de la cavité, un schéma d’asservissement reposant sur la rétroaction optique est utilisé.Une première partie décrit le couplage optique entre le laser et la cavité à travers l’analyse du comportement de la fréquence d’émission du laser auto-réinjecté. Une comparaison analytique théorie expérience a permis d’identifier les signaux d’erreur nécessaires au maintien durable de la fréquence du laser à l’exacte résonance d’un mode de la cavité. Après une description détaillée du dispositif d’asservissement, sa réalisation expérimentale sur une cavité de finesse de quelques milliers (F = 3 000)a démontré la possibilité de stabiliser la fréquence laser sur plus de dix heures avec une excursion résiduelle à la seconde de 375 Hz.Dans la deuxième partie, le développement précédent a été mis en œuvre sur une cavité de très haute finesse (F = 250 000) et a permis la mesure ultrasensible de biréfringence induite dans des gaz par effet Kerr. L’originalité du dispositif repose sur la mise à profit de la biréfringence résiduelle des miroirs de haute réflectivité.Elle est utilisée d’une part comme source à la rétroaction optique, et d’autre part comme biais optique à la mesure de la biréfringence du gaz. Une étude théorique et expérimentale détaillée des sources de bruit présent dans la chaîne de détection en fonction de la valeur du biais optique a permis de réaliser la mesure de déphasage au niveau du bruit de photons avec quelques mW de puissance laser. Ainsi, une sensibilité référence sur la mesure de déphasage Kerr de 3.10−13 rad a été démontrée pour un temps de mesure de 800 sec. Cette valeur record améliore de trois ordres de grandeur les déphasages Kerr précédemment mesurés. Le dispositif a été de plus mis à profit pour la mesure à faible champ électrique (< 40 V /mm) et à pression atmosphérique, des constantes de Kerr de différents gaz moléculaires et atomiques jusqu’à l’He. / The context of the work is the ultra-sensitive measurement of phase anisotropy permits by well-used of very high finesse cavity. To stabilize the laser frequency at the exact resonance of one cavity mode, a servo control based on optical feedback is used.In the first part, the optical coupling between laser and cavity is described through the comportment of the frequency of the self-locked laser. A comparison between experience and theory has permitted to identify the error signals in order to keep enduringly the laser frequency at the exact resonance. The experimental realization of the servo control into a 3 000 finesse cavity had demonstrated the stabilization of the laser frequency during more than ten hours with a residual one second excursion of 375 Hz.In the second part, the previous development has been used with a very high finesse cavity (F=250 000) to measure static Kerr birefringence in gases. The originality of the set-up is the use of the residual high reflectivity mirrors birefringence, firstly as the source of the optical feedback and secondly as an optical bias to measure the weak gas birefringence. An experimental and theoretical study of the noise according to the value of the optical bias has permitted a photon noise limited measurement (laser intensity of few mW). A record sensitivity of the phase shift induced by Kerr effect has been demonstrated at 3.10-13 rad with 800 s integration time. The scheme has been used to measure, in weak electric field (<40 V/mm) and in standard condition of pressure and temperature, the Kerr constant of molecular and atomic gases, even He gas
5

Vers l’observation du bruit quantique de la pression de radiation dans un interféromètre suspendu : l’expérience QuRaG / Towards the observation of the radiation pressure noise in a suspended interferometer : the QuRaG experiment

Di Pace, Sibilla 15 December 2014 (has links)
L'existence des ondes gravitationnelles (OG) est l'une des prédictions les plus intéressantes de la théorie de la Relativité Générale d'Einstein. La découverte expérimentale des OG serait donc un test important de la théorie elle-même et permettra d'ouvrir une nouvelle fenêtre d'observation en particulier dans les régions de l'Univers inaccessible à l'observation électromagnétique. Les détecteurs interférométriques, comme Virgo, sont les dispositifs les plus prometteurs pour la détection d’OG. Actuellement, leur sensibilité n'est pas encore suffisante pour avoir un taux d'observation de quelques événements/an. Un intense programme expérimental pour l’améliorer est en cours. Particulièrement, les prochaines générations de détecteurs d'OG, aux basses fréquences, seront limitées par l'effet de la pression de radiation (PR) sur les miroirs suspendus. Ce phénomène, pas encore observé expérimentalement, est l'objet d'un champ de recherche très actif. Mon travail ici présenté vise à la construction d'un détecteur pour l'étude des effets quantiques de la PR dans les détecteurs d’OG: QuRaG. Il sera constitué d'un interféromètre de Michelson suspendu dont chaque bras sera une cavité Fabry-Pérot de très haute finesse, dans laquelle seulement le miroir de fond sera suspendu et sensible au bruit quantique de la PR. Durant ma thèse j'ai participé activement au R&D de tous les sous-systèmes de QuRaG. Par conséquent, le travail que j'ai fait porte sur divers aspects du projet dont les problématiques appartiennent à différents domaines de la physique. Mon travail présenté ici démontre que QuRaG sera réalisable et qu’il observera le bruit de la PR dans la bande de fréquences attendue. / The existence of gravitational waves (GW) is one of the most interesting predictions of the theory of general relativity of Einstein. The experimental discovery of GW would be an important test of the theory itself. In addition, the detection of GW will open a new window of observation especially in those regions of the Universe inaccessible to electromagnetic observations. Interferometers, as Virgo are the most promising devices for the detection of GW. Currently, the sensitivity of these detectors is not yet sufficient to have a detection rate of few events/year. Therefore, an intense experimental program to improve the sensitivity is underway. Specifically, the sensitivity of the next generations of GW detectors, at low frequencies, will be limited by the effect of the radiation pressure (RP) on the suspended mirrors. This phenomenon not yet observed experimentally in the ground based GW detectors band, is currently the subject of a very active research field. My work presented here aims at building a detector for studying quantum effects of RP in GW detectors: the QuRaG experiment. It will consist of a suspended Michelson interferometer where each arm will be a high finesse Fabry-Pérot cavity, in which only the end mirror will be further suspended and then sensitive to the RP noise. During my PhD I have actively participated to the R&D of all QuRaG subsystems. Therefore, the work that I have done deals with various aspects of the project whose related problems belong to different domains of physics. My work described in this manuscript demonstrates that QuRaG is realizable and that it will be able to observe the RP noise in the expected frequency range.

Page generated in 0.0737 seconds