• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 4
  • 1
  • 1
  • Tagged with
  • 25
  • 25
  • 15
  • 14
  • 11
  • 11
  • 8
  • 8
  • 8
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

INFLUÊNCIA DA SMEAR LAYER NA PROFUNDIDADE DE DESMINERALIZAÇÃO E NA ESPESSURA DE CAMADA HÍBRIDA FORMADA POR SISTEMAS ADESIVOS ATUAIS. / INFLUENCE OF SMEAR LAYER IN THE DEPTH OF DEMINERALIZATION AND THE THICKNESS OF HYBRID LAYER PRODUCED BY CURRENT ADHESIVE SYSTEMS

Skupien, Jovito Adiel 24 February 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the thickness of hybrid layer and the depth of demineralization produced by adhesive systems applied in dentinal surfaces submitted to different treatments. Dentin slices extracted from 20 caries free human third molars were divided in two groups. One was polished with 60-grit SiC paper while the other was polished with 600-grit SiC. The samples were prepared to receive the treatment with self-etching adhesive systems: Adhe SE (AD), Clearfil SE Bond (CL), G Bond (GB) and total-etching adhesive system Adper Single Bond (SB). After treatment, the samples were fractured and prepared for SEM, to analyze the smear layer produced with each paper, the effect of conditioners and the thickness of hybrid layer produced by adhesives used. The data were analyzed through ANOVA, with multiple comparisons post hoc using Tukey´s test. Correlation between depth of demineralization and thickness of hybrid layer was tested through Spearman s correlation coefficient. Adhesive system and smear layer influenced the thickness of hybrid layer, where, the highest values were obtained for SB while the lowest, for GB. The phosphoric acid was able to demineralize dentin deeper, whereas GB did not promote any demineralization. The conditioners were more efficient on thin smear layer. It was demonstrated a direct correlation between depth of demineralization and thickness of hybrid layer. The smear layer was able to influence the depth of demineralization and thickness of hybrid layer, however, for the total-etching adhesive system, the thickness of hybrid layer was independent of that. / O objetivo do estudo foi avaliar a espessura de camada híbrida e a profundidade de desmineralização produzida por sistemas adesivos aplicados sobre superfícies dentinárias submetidas a diferentes tratamentos. Discos de dentina retirados de 20 dentes terceiros molares humanos livres de cárie foram seccionados, onde a metade foi submetida ao tratamento com lixa 60# e a outra metade com lixa 600#. As amostras foram preparadas para receberem tratamento com os sistemas self-etching Adhe SE (AD), Clearfil SE Bond (CL), G Bond (GB) e o sistema total-etching Adper Single Bond (SB). Após aplicação, as amostras foram fraturadas e preparadas para a visualização em MEV, onde foi possível analisar a smear layer formada por cada lixa, a ação do condicionador e a espessura de camada híbrida formada pelos sistemas adesivos utilizados. Os dados foram analisados através do teste ANOVA, com comparações múltiplas post hoc realizadas utilizando teste de Tukey. Correlação entre profundidade de desmineralização e espessura de camada híbrida foi testada através do coeficiente de relação de Pearson. Sistema adesivo e smear layer influenciaram na espessura de camada híbrida, onde, os maiores valores encontradas foram para SB e os menores para GB. O ácido fosfórico foi capaz de desmineralizar a dentina mais profundamente, enquanto que GB não promoveu nenhuma desmineralização. Os condicionadores foram mais eficazes sobre smear layer delgada. Ficou demonstrada uma correlação direta entre profundidade de desmineralização e espessura de camada híbrida. A smear layer é capaz de influenciar a profundidade de desmineralização e espessura de camada híbrida para os sistemas adesivos testados, porém, para o sistema adesivo total-etching a camada híbrida independe desta.
22

Estudo da influência das soluções desmineralizadoras na atividade proteolítica da dentina humana sadia / The influence of demineralizing solutions in the proteolytic activity of human dentin healthy

André Guaraci De Vito de Moraes 25 October 2012 (has links)
A degradação da interface adesiva em dentina pode acometer tanto a porção resinosa como a porção orgânica da camada híbrida. Evidências indicam que a degradação da porção orgânica pode ocorrer em parte devido a atividade enzimática de proteases da própria dentina. As metaloproteinases da matriz (MMPs) constituem a primeira classe de enzimas relacionada com a degradação da matriz orgânica. É possível que as MMPs, possam ser reativadas durante o procedimento adesivo em conseqüência da queda do pH do meio. Objetivo: Esta investigação teve como objetivos avaliar a influência de soluções desmineralizadoras com diferentes concentrações de ácido fosfórico (AF1%, AF10% e AF37%) na atividade proteolítica da dentina humana sadia, na degradação do colágeno exposto pela desmineralização, além de identificar imunologicamente as metaloproteinases. Material e Métodos: Vinte dentes molares permanentes foram triturados para obtenção de um pó de dentina. Alíquotas de 1g do pó foram acondicionadas em tubos plásticos para que a desmineralização do substrato pudesse ser realizada de acordo com as três diferentes concentrações de ácido fosfórico testadas. Após a neutralização do ácido com NaOH, as amostras foram centrifugadas. O sobrenadante foi utilizado para mensuração espectrofotométrica do conteúdo de Cálcio (Ca) liberado pela desmineralização. O precipitado obtido foi incubado com tampão de extração de proteínas por 24h a 4°C sob agitação. Nova centrifugação foi realizada e o sobrenadante utilizado para avaliação da atividade da MMP-2 e MMP-9 por zimografia e para a identificação imunológica das metaloproteinases por western blot. O precipitado obtido pela centrifugação foi liofilizado e separado em alíquotas de 40mg (n=10) de pó de dentina para cada condição experimental. As alíquotas foram incubadas em saliva artificial por 24h a 37°C sob agitação e hidrolisadas em autoclave. Após incubação a 65°C por 40 min, as amostras foram avaliadas por espectrofotometria para que a mensuração da concentração do aminoácido hidroxiprolina (HYP) liberado pela degradação do colágeno exposto pudesse ser obtida. Fatias de 0.3 mm da dentina coronária de outro dente foram obtidas e desmineralizadas, de acordo com as diferentes concentrações de ácido fosfórico para avaliação da atividade enzimática através do método da zimografia in situ. Os resultados foram submetidos à análise de variância de um fator sem vinculação ou teste de Kruskal-Wallis para identificação das diferenças existentes entre os grupos experimentais. Para contraste das médias foi realizado o teste de Student-Newman-Keuls com nível de significância de 5% (=0,05). Resultados: A atividade enzimática de MMP-2 foi estatisticamente maior quando a dentina foi desmineralizada com AF 1% ou 10%. O uso do ácido fosfórico 37% diminuiu consideravelmente a atividade desta enzima, em relação ao AF10% (<0,05). Em nenhuma das amostras desmineralizadas com AF foi detectada a atividade enzimática da MMP-9. A identidade da MMP-2 foi confirmada pelo immunoblotting da enzima com anticorpo específico. A MMP-9 não foi expressa nos extratos analisados. A expressão de MMP-2 foi maior quando utilizado AF 1% ou 10% e menor quando foi utilizado o AF 37%. A utilização do AF 37% liberou valores de Ca, em g/mL, estatisticamente superiores aos valores determinados para os demais grupos (<0,05). A maior concentração de HYP, em g/mL, foi encontrada nos extratos desmineralizados com AF 10%. Em seguida, aparecem os valores encontrados com o uso do AF1%. Os menores valores da concentração de HYP aparecem no grupo em que foi utilizado o AF 37% (<0,05). A concentração de HYP em função do peso de dentina utilizado (40mg) também foi calculada. A maior concentração de HYP por mg de dentina foi obtida com AF 10%, seguida pelos extratos desmineralizados com AF1%. Os menores valores foram detectados com AF 37% (<0,05). O uso do AF10% demonstrou ser responsável pela maior taxa de degradação de colágeno exposto (20,13%). Em seguida, aparecem valores intermediários (11,34%) obtidos com AF1%. Por último, surgem os menores valores (0,68%) com AF37%. A análise das imagens obtidas após a realização da zimografia in situ demonstrou maior atividade enzimática quando a dentina foi desmineralizada com AF10%. Conclusão: O uso do AF37% para o condicionamento da dentina durante a realização do procedimento adesivo pode minimizar os efeitos degradantes das proteases endógenas sobre o colágeno. Em contrapartida, estudos realizados com pó de dentina desmineralizado com AF1% ou 10% podem estar sobreestimando a atividade das MMPs, em relação à prática clínica. / The dentin adhesive interface degradation can occur in resin and in organic portion of the hybrid layer. Evidence indicates that the degradation of organic matrix may partially occur due to the enzymatic activity of proteases own dentin. The matrix metalloproteinases (MMPs) have been described as the first class of enzymes associated with degradation of the organic matrix. It is possible that MMPs may be reactivated during the adhesive procedure as a result of the fall of pH. Purpose: The objectives of the present investigation are to evaluate the influence of different demineralizing phosphoric acid solutions (PA1%, PA10% and PA37%) on the proteolytic activity of human sound dentin, on the collagen degradation that was exposed after demineralization, as well as to identify the metaloproteases immunologically. Material and Methods: Dentin powder was obtained from twenty human molars. One gram aliquots were placed in polyestyrene tubes and the dentin demineralization was performed using the three different phosphoric acid concentrations tested in this study. After neutralization with NaOH, the samples were centrifuged. The supernatant was used for the spectrophotometrically quantification of calcium (Ca) released by the demineralization while the precipitate was re-suspended and incubated with a protein extraction buffer for 24h at 4ºC under agitation. The sample was centrifuged and the supernatant was used for the identification of MMP-2 and MMP-9 by western blot and for the evaluation of gelatinolytic activity by zymography. The pellet was lyophilized and 40 mg aliquots of the dentin powder (n=10) were incubated in artificial saliva for 24h at 37°C under agitation and hydrolysed in autoclave after incubation at 65°C for 40 min. The samples were analyzed spectrophotometrically to measure the hydroxyproline (HYP) released after collagen degradation. Slices of 0.3 mm of the dentine crown of the another tooth were obtained and demineralized in accordance with the concentrations of phosphoric acid used in this study for evaluating the enzymatic activity by the method of in situ zymography.The data were analyzed by ANOVA one-way or Kruskal-Wallis test for the identification of differences between the experimental groups. The means were analyzed by Student-Newmans-Keulss test (=0,05). Results: The MMP-2 enzymatic activity was statistically higher when the dentin was demineralized with 1% or 10% PA. The 37% phosphoric acid decreased the activity of such enzyme relative to PA 10% (<0,05). MMP-9 activity was not detected in any demineralization condition (1%, 10% or 37% PA). MMP-2 identification was confirmed by immunoblotting while MMP-9 was not observed in any condition. MMP-2 identification was higher when 1% or 10% PA were used while 37% PA showed lower MMP-2 identification. The use of 37% PA resulted in higher release of Ca, which was significantly higher when compared to other PA concentrations (<0,05). The highest HYP concentration was observed when 10% PA was used, followed by 1% PA. The lowest values were observed for 37% PA (<0,05). The HYP concentration according to the dentin weight used (40 mg) was also calculated. Highest concentrations of HYP per mg of dentin were observed for 10% and 1% PA, while 37% PA resulted in the lowest HYP concentration (<0,05). The use of 10% PA showed to be responsible for the highest exposed collagen degradation after demineralization (20,13%) when compared to 1% PA (11,34%) and 37% PA (0,68%). The analysis of images obtained after the realization of in situ zymography showed greater enzyme activity when the dentin was demineralized in PA10%. Conclusion: The use of 37% PA for dentin etching during the restorative procedure might minimize collagen degradation by host-derived proteases. On the other hand, studies that have been using 1% or 10% PA might have overestimated MMPs activity when compared to the clinical situation.
23

Réalisation et caractérisation des cellules photovoltaïques organiques / Realization and charactenziation of organic photovoltaic cells

El jouad, Zouhair 18 October 2016 (has links)
Cette thèse s’insère dans un projet d’élaboration et de caractérisation des cellules photovoltaïques organiques classiques et inverses, plus précisément il s’agit d’améliorer les performances des cellules via des couches tampons anodiques et cathodiques originales. Nous avons commencé d’améliorer les couches tampons cathodiques avec différents donneurs d’électrons: phtalocyanine de cuivre CuPc, subphtalocyanine SubPc et dérivés de thiophène organiques. Dans le premier cas de donneur d’électrons (CuPc), nous avons mis en évidence l’effet d’une fine couche d’un composé de césium, utilisée comme couche tampon cathodique dans des cellules inverses, sur la collecte des électrons après un traitement thermique. Nous avons montré aussi que la couche tampon cathodique hybride, Alq3 (9nm) / Ca (3nm) améliore les performances des cellules quelque soit le donneur d’électrons et sans nécessité de recuit. Dans le cas de drivés de thiophène, nous avons montré comment la morphologie de surface des couches organiques peut influencer les performances des cellules photovoltaïques organiques. Et dans le cas de SubPc utilisé dans des cellules inverses, nous avons étudié l’effet de la vitesse de dépôt de la couche SubPc sur sa morphologie. Concernant l’amélioration de la couche tampon anodique, nous avons étudié des cellules classiques à base SubPc et du pentathiophene (5T). Après l’optimisation de l’épaisseur des donneurs d’électrons, nous avons montré que la bicouche MoO3 (3 nm) / Cul (1,5 nm) utilisée comme couche tampon anodique, permet d'améliorer les performances des cellules, quelque soit le donneur d’électrons. Dans le cas du SubPc, nous avons obtenu un rendement qui approche de 5%. / This thesis concerns elaboration and characterization of classical and inverse organic photovoltaic cells, specifically improving the anodic and cathodic buffer layers. We started by improving the cathode buffer layers with different electron donors: copper phthalocyanine CuPc, subphtalocyanine SubPc and thiophene derivatives (BSTV and BOTV). In the first case of electron donor (CuPc), we highlighted the effect of the thin layer of cesium compound, used as a cathodic buffer layer in inverse cells, on the collection of electrons after heat treatment.We have also shown that the hybrid cathodic buffer layer, Alq3 (9 nm) / Ca (3nm) improves the cell performance whatever the electron donor without annealing. In the case of thiophene derivatives, we have shown how the morphology of the organic layers surface can influence the performance of organic photovoltaic cells. In the case of SubPc used in inverse cells, we studied the effect of the deposition rate of the layer on the morphology of SubPc surface.Regarding the improvement of the anodic buffer layers, we investigated those based on the SubPc and pentathiophene (5T) in classical cells. After optimization of the electron donors thickness, we have shown that the bilayer MoO3 (3 nm) / CuI (1.5 nm) used as an anodic buffer layer, improves cell performances, whatever the electron donor. In the case of SubPc, we obtained a efficiency approaching 5%.
24

Physikochemische und bioaktive Eigenschaften von mit Methacryl-funktionalisierten Silica-Nanopartikeln modifizierten experimentellen Adhäsiven / Physico-chemical and bioactive properties of methacryl-functionalized silica-nanoparticles modified experimental adhesives

Manzke, Marietta Simone 02 June 2020 (has links)
No description available.
25

Inibição da metaloproteinase 2 por dois monômeros amplamente utilizados na formulação de adesivos dentinários / Inhibition of metalloproteinase 2 by two monomers thoroughly used on the dentin bonding formulation.

Carvalho, Rodrigo Varella de 30 January 2009 (has links)
Made available in DSpace on 2014-08-20T14:30:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-01-30 / The aim of this study was to evaluate the effect of different concentrations of 2-hydroxyethyl methacrylate (HEMA) triethyleneglycol dimethacrylate (TEGDMA) on the inhibition of matrix metalloproteinase 2 (MMP-2). Mouse gingival explants were cultured overnight in DMEM and the expression of secreted enzymes was analyzed by gelatin zymography in buffers containing 5 mM CaCl2 (Tris-CaCl2) in 50 mM Tris-HCl buffer with the addition of HEMA and TEGDMA at different concentrations (0.62, 1.25, 2.5 or 5.0% (v/v)). The gelatinolytic proteinase present in the conditioned media was characterized as matrix metalloproteinase by means of specific chemical inhibition with 0.5 mM of EDTA and 0.5 mM of NEM. The matrix metalloproteinases present in the conditioned media were characterized as MMP-2 by immunoprecipitation.The eletrophoretic bands were scanned and the transmittance values were analyzed with ImageJ software. Data was plotted and submitted to linear regression to investigate MMP-2 inhibition as a function of HEMA and TEGDMA concentration. Three major bands were detected in the zymographic assays. Those bands were characterized as MMP-2. Zymogene (72 kDa), intermediate (66 kDa) and active forms of MMP-2 (62 kDa) were inhibited by HEMA and TEGDMA in a dose-dependent way. These findings suggest that HEMA and TEGDMA could inhibit MMP-2 expression even at small concentrations. / O objetivo do presente estudo foi avaliar o efeito de diferentes concentrações de 2-hidroxietil metacrilato (HEMA) e trietilenoglicol dimetacrilato (TEGDMA) na inibição da metaloproteinase da matriz 2 (MMP-2). Tecidos gengivais de ratos foram incubados em DMEM e a expressão das enzimas secretadas foi analisada por zimografia em tampões de incubação contendo 5 mM de CaCl2 (Tris-CaCl2) em 50 mM de Tris-HCl com a adição de diferentes concentrações de HEMA e TEGDMA (0,62; 1,25; 2,5 e 5%) em volume. Para caracterizar as enzimas como MMPs foi realizado ensaio de inibição química específica com 0,5 mM de EDTA (um conhecido inibidor de MMPs) e 0,5 de NEM (um conhecido inibidor de proteinases serinas).Para caracterizar as enzimas como MMP-2 foi realizado o ensaio de imunoprecipitação. As bandas produzidas no gel foram escaneadas e os valores de transmitância foram analizados com o auxílio do programa ImageJ. Os resultados foram submetidos a regressão linear em função da concentração de HEMA e TEGDMA. Três bandas foram identificadas após a zimografia. Essas bandas foram caracterizadas como MMP-2. O zimogênio (72 kDa), a forma intermediária (66 kDa) e a forma ativa da MMP-2 (62 kDa) foram inibidas pelo HEMA e pelo TEGDMA de forma dose-dependente. Nossos resultados sugerem que o HEMA e o TEGDMA podem inibir a expressão da MMP-2 mesmo em pequenas concentrações.

Page generated in 0.0777 seconds