• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 61
  • 13
  • 7
  • 6
  • 4
  • 2
  • 2
  • 1
  • Tagged with
  • 96
  • 31
  • 24
  • 18
  • 18
  • 16
  • 13
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

DSP audio procesor pro laboratorní výuku / DSP audio processor for laboratory measurements

Struhelka, Michal January 2015 (has links)
This project deals with the subject of laboratory preparation for low-frequency and audio electronics. It is used DSP audio processor with integrated ADCs and DACs converters ADAU1701 from Analog Devices. Also, Atmel microcontroller with a connected graphic LCD display and buttons is used for adjusting DSP. The work presents the complete instructions of the laboratory project with a model protocol.
12

Bezdrátová meteorologická stanice / Wireless weather station

Mieržwinský, Leon January 2016 (has links)
The diploma thesis is focused on the design and implementation of a prototype wireless home weather station. The goal is to measure the air temperature, relative humidity and atmospheric pressure. Measured data are stored in external memory and it is posibility to send to the computer for subsequent processing and evaluation.
13

Keep Talking : Fysisk version av ett virtuellt spel / Keep Talking : Physical Version of a Virtual Game

Olm, Måns, Adam, Rör January 2021 (has links)
”Keep Talking and Nobody Explodes” är ett spel som normalt spelas med ”vitual reality”-glasögon på en spelkonsol. Spelet går ut på att två spelare ska sammabeta för att lösasex pussel på tid för att desarmera en bomb. En person ser bomben och ska förklarahur den ser ut för den andra personen som, med hjälp av en manual, ska berätta hurpusslet ska lösas baserat på utseendet. I denna rapport beskrivs utvecklingen av en fysiskvariant av detta spel. Utmaningen med att utveckla spelet var att designa inbyggdasystem som efterliknade det virtuella spelet så mycket som möjligt. I utvecklingeningick både design av elektriska kretsar och programmering av mikroprocessorer. Syftetmed rapporten är att ge ett exempel på hur en fysisk produkt kan utvecklas från envirtuell variant och vilka för- och nackdelar de båda varianterna kan ha. Resultatet frånprojektet blev ett spel som efterliknade den virtuella versionen med ett pussel, samt enkravspecifikation för vidare utveckling av pussel. / ”Keep Talking and Nobody Explodes” är ett spel som normalt spelas med ”vitual reality”-glasögon på en spelkonsol. Spelet går ut på att två spelare ska sammabeta för att lösasex pussel på tid för att desarmera en bomb. En person ser bomben och ska förklarahur den ser ut för den andra personen som, med hjälp av en manual, ska berätta hurpusslet ska lösas baserat på utseendet. I denna rapport beskrivs utvecklingen av en fysiskvariant av detta spel. Utmaningen med att utveckla spelet var att designa inbyggdasystem som efterliknade det virtuella spelet så mycket som möjligt. I utvecklingeningick både design av elektriska kretsar och programmering av mikroprocessorer. Syftetmed rapporten är att ge ett exempel på hur en fysisk produkt kan utvecklas från envirtuell variant och vilka för- och nackdelar de båda varianterna kan ha. Resultatet frånprojektet blev ett spel som efterliknade den virtuella versionen med ett pussel, samt enkravspecifikation för vidare utveckling av pussel.
14

SERIAL PROTOCOL BRIDGE

Sharma, Neena January 2012 (has links)
No description available.
15

Testbänk till styrenheter via CANalyzer och Arduino : - En studie om systemutveckling

Lovén, Lucas, Åkerblom, Philip January 2019 (has links)
Syftet med arbetet var att undersöka möjligheten att utveckla en testbänk som kan underlätta felsökning och testning till fem olika ECU:er. 93 utgångar, bland annat DAC:ar, digitala- och frekvensutgångar finns med i kravspecifikationerna. Dessa utgångar styrs utifrån paneler i CANalyzer med hjälp av programmering i Arduino och CANalyzers egna språk CAPL. Testbänken visar goda resultat och har fått positiv respons från företaget, den levererar de förväntade värdena på samtliga 93 utgångar med en felmarginal på max 3%. Det finns begränsningar med att bygga denna typ av testbänk kopplade till komponentval, tid och resurser.
16

Automatizované testovací zařízení pro výstupní kontrolu výrobků / Automatic tester for quality control

Vítek, Radim January 2019 (has links)
The thesis deals with design and construction of device for automatic product inspection. Thesis describes methods for testing products during manufacture. Thesis describes their main advantages and disadvantages. The main part of this thesis is design of testing device. There is described method of designing this device. It describes design of software and hardware.
17

Digitálně řízený rezistor / Digital controlled resistor

Sedlář, Petr January 2009 (has links)
This master´s thesis deals with the design of the control circuits for digital potentiometers and their application in analog systems. Digital potentiometers are three-terminal resistors with an adjustable center connection. The digital potentiomneters enable to drive logic gates, LED drivers, LCD drivers, analog switches etc. Controlling of these mentioned devices is possible by the I2C 2- wire serial bus (invented by Philips). The digital potentiometers are used to control of the primary parameters like cut-off frequency and quality factor in the state variable filter and cut-off frequency in a passive filter. Both filters are simulated in PSpice and then compared with the measured results. Next parts of this master's thesis are a computer program and a exemplary protocol.
18

Systém pro přesné měření elektrické délky koaxiálních kabelů / System for Precise Measurement of Electrical Length of Coaxial Cables

Podr, Michal January 2015 (has links)
This thesis describes a study of the measuring methods determining the electrical length of coaxial cable without using a vector network analyzer. First, a general theory of management and its various parameters is briefly discussed. This section is focused more specifically on the coaxial cable and its parameters. The next part is graphically analyzed process considerations in the design of measurement methods and outlined the block structure of the system. The third section describes the working process, prototype testing of the bridge, its measurement and design of the measuring system. In the fourth part the software is described. In conclusion, the results of the work are discussed, accuracy of the measurement system, the obtained parameters chosen with regard to the principle of the measurement system and the overall evaluation of the applicability in practice.
19

Developing a Portable System for Medicine Dosage

Richert, Adam January 2018 (has links)
The project presented in this report is set out to develop a portable electronic system to be used as a medicine pill container. With the functionality to configure up to twelve daily repeated alarms, the purpose of the medicine dosage system is first and foremost to remind the user when they should take their medicine. Secondly, LED lights and user-recorded voice notifications are to be implemented to further aid the user in taking the right medicine each time. The device is also to have a memory log, recording up to one hundred missed dosages, enabling an authorized medicine professional to verify the medicine adherence of the user.Prior to the start of the project, an outline for the functionality and physical appearance of the device was set by the project owner, Victrix AB. This project covers the hardware and software development, as well as the design choices within. The aim is to follow the proposed functionality specification as close as possible, while making justified hardware and software choices considering simplicity, efficiency, power consumption, and availability. By following the specification, the goal is ultimately to increase the medicine adherence for users of the device developed with this thesis.Using qualitative research methods, a valid background study was created, preceding the development of the medicine dosage system. Hardware for a first prototype of the device was then chosen based on the gathered information about existing technologies and related work. With thorough testing and recurrent information exchange with the client, a prototype of the medicine dosage system, based on an Arduino microcontroller, was constructed. The prototype was evaluated to fulfill 92% of the requirements considered as high priority by Victrix. / Projektet som presenteras i denna rapport är tänkt att utveckla ett portabelt elektroniskt system för användning som en medicinsk pillerbehållare. Med funktionaliteten att konfigurera upp till tolv dagligen upprepande alarm är syftet med medicindoseringssystemet först och främst att påminna användaren när de ska ta sin medicin. Lysdioder och användarens egna inspelade röst som notifikationer ska implementeras för att vidare hjälpa användaren att ta rätt medicin vid varje tillfälle. Enheten ska också ha en minneslogg som sparar upp till etthundra missade doseringar, vilket gör det möjligt för auktoriserad sjukvårdspersonal att verifiera användarens följsamhet till medicineringen.En översiktlig beskrivning av funktionaliteten samt det fysiska utseendet av enheten skrevs av projektägaren Victrix AB innan projektet startades. Det som detta projekt täcker är hårdvaruoch mjukvaruutvecklingen, så väl som där tillhörande designval. Projektet siktar på att följa den föreslagna funktionalitetsspecifikationen så nära som möjligt, och samtidigt göra välgrundade val för hårdoch mjukvara med enkelhet, effektivitet, energiförbrukning och tillgänglighet i åtanke. Genom att följa specifikationen är det slutliga målet att frambringa ökad medicinföljsamhet för användare av den med det här projektet utvecklade enheten.Utvecklingen av medicindoseringssystemet föregicks av en befogad bakgrundsstudie utformad genom användningen av kvalitativa forskningsmetoder. Hårdvara att användas för en första prototyp av enheten valdes sedan baserat på den insamlade informationen om existerande teknologier och relaterat arbete. Genom grundliga tester och regelbundet informationsutbyte med kunden konstruerades en prototyp av medicindoseringssystemet baserat på en Arduinomikrokontroller. Prototypen utvärderades att uppfylla 92% av kraven som Victrix ansåg vara av hög prioritet.
20

Undersökning av stabilitet och noggrannhet hos kapacitans baserade fuktgivare i ett varierande klimat

Grufman, Samuel January 2023 (has links)
Studien gick ut på att undersöka och ta fram relativa luftfuktighetsgivare som ger godkända mätvärden mellan [5%, 95%] relativ luftfuktighet med klimatkammare som referens. Med syftet att ersätta företagets givare i deras NDIR koldioxidsensor. Den skulle ersättas då deras nuvarande luftfuktighetsgivare gav felaktiga värden när klimatet gick mot antingen väldigt torrt eller fuktigt. Det är väsentligt att luftfuktighetsgivaren fungerar eftersom företaget använder värdena från givaren för att ge korrekta koldioxidmätningar i deras NDIR sensor. Detta är möjligt eftersom koldioxidhalter har visats sig påverkas av den relativa luftfuktigheten. Givarna införskaffades och monterades på PCB’s. Kod utvecklades för insamling av data genom I2C och SPI kommunikation. Givarna kördes sedan i en klimatkammare som svepte luftfuktigheten mellan [5%, 95%]. Värdena illustrerades i Matlab genom grafer. Givare 2 visade sig ge bäst värden på hela spannet jämfört med resterande givare. Den hade absolut minst avvikelse vid extrempunkterna, samt låg nära referensvärdet vid resterande luftfuktigheter i svepet [5%, 95%]. / The purpose of the study was to examine and bring forth a relative humidity sensor which gives approved values for the span between [5%, 95%] relative humidity with the climate chamber as the reference point. The goal was to replace the companies relative humdity sensor in their NDIR carbon dioxide sensor. It was to be replaced because their current sensor gave incorrect values when the climate was really humid or dry. It’s of value that the sensor gives correct values because the company uses relative humdity readings to correct their carbon dioxide reading in their NDIR sensor. The reason this works is because the carbon dioxide levels has been showed to correlate with the relative humidity. The sensors were studied and bought. They were mounted on top of PCB’s. Code was developed to gather data from I2C and SPI communication. The sensors was then put into an climate chamber and got swept between [5%,95%] relative humidity. The values were illustrated in Matlab through graphs. Sensor 2 proved to give the best values on the entire span [5%, 95%] relative humidity in comparison to the other sensors in the study. It had the least added error of all the sensors at dry/humid climates and was really close to the reference value at the other points of span [5%, 95%] relative humidity.

Page generated in 0.0414 seconds