• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 833
  • 523
  • 82
  • 45
  • 31
  • 24
  • 21
  • 21
  • 20
  • 20
  • 19
  • 17
  • 13
  • 12
  • 11
  • Tagged with
  • 1885
  • 853
  • 745
  • 493
  • 257
  • 239
  • 196
  • 185
  • 175
  • 148
  • 141
  • 134
  • 133
  • 128
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
561

Efeito do MEI (multiple exemplar instruction) na integração entre repertórios de ouvinte e falante em crianças com desordem do espectro da neuropatia auditiva e implante coclear /

Merlin, Adriana Maura Barboza. January 2017 (has links)
Orientador: Ana Cláudia Moreira Almeida-Verdu / Banca: Adriane Lima Mortari Moret / Banca: Alessandra Turini Bolsoni Silva / Resumo: Estudos da parceria entre a Fonoaudiologia e Análise do Comportamento têm investigado sob quais condições de ensino implantados cocleares pré-linguais aprendem habilidades auditivas e as relações que estabelecem com a produção oral. Uma rota que permite a extensão do controle entre repertórios verbais é o Ensino por Múltiplos Exemplares (do inglês Multiple Exemplar Instruction, MEI), que tem sido pouco explorada em estudos com usuários de implante coclear. Este estudo objetivou investigar o efeito do ensino por MEI sobre a integração entre repertórios de ouvinte e falante em crianças com Desordem do Espectro da Neuropatia Auditiva (DENA) e usuárias de implante coclear (IC). Participaram três crianças com 6 anos de idade, uma do sexo feminino e duas do sexo masculino, com o diagnóstico de DENA e um quadro de perda auditiva severa-profunda, bilateral e pré-lingual. Todos os participantes usavam implante coclear uni ou bilateral, frequentavam o ensino regular e recebiam atendimento multidisciplinar no follow-up do serviço de implante coclear. Os participantes apresentavam maturidade intelectual típica e reconhecimento auditivo inferior à idade cronológica, aferidos pela Escala Colúmbia de Maturidade Intelectual e o Peabody Picture Vocabulary Test (PPVT-4R). Foram adotados estímulos auditivos e figuras que corresponderam às palavras (substantivos) e sentenças de dois termos (substantivos+adjetivos), que foram convencionais (para GABI e SOZA) e não convencionais (para DOZA). O est... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Studies of the partnership between Speech-Language Pathology and Behavioral Analysis have investigated under which teaching conditions that pre-lingual implanted cochlear learn listening skills and the relations that establish with oral production. A route that can be to promote the extension of control between verbal repertoires is designated Multiple Exemplary Instruction (MEI), which has been little explored in studies with cochlear implants users. This study aimed to investigate the effect of MEI' teaching on the integration between listening and speaking repertoires in children with Auditory Neuropathy Spectrum Disorder (DENA) and cochlear implants users (CI). Participants were three 6-year-old children, one female and two males, with the diagnosis of DENA and a severe-profund, bilateral and pre-lingual hearing loss. All participants used a uni or bilateral cochlear implant, attended regular education and received multidisciplinary care in the follow-up of the cochlear implant service. Participants had typical intellectual maturity and auditory recognition lower the chronological age, measured by Columbia and PPVT-4R tests. Auditory stimuli and figures that corresponded to words (nouns) and sentences of two terms (nouns + adjectives) were used, which were conventional (GABI and SOZA) and nonconventional (DOZA). The study employed a multiple probe design and was composed of probes and teaching. The probes were intercalated with the teaching and evaluated the conditional a... (Complete abstract click electronic access below) / Mestre
562

Influência da nicotina na osseointegração de implantes instalados em tíbias de ratos: avaliação biomecânica, histológica, histométrica e imunoistoquímica / Influence of nicotine on osseointegration of implants installed in the tibia of rats: biomechanical, histological, histometric and immunohistochemical evaluation

Faleiros, Paula Lazilha [UNESP] 05 July 2016 (has links)
Submitted by PAULA LAZILHA FALEIROS null (paulal.faleiros@hotmail.com) on 2016-08-03T13:15:45Z No. of bitstreams: 1 TESE DE DOUTORADO - PAULA FINAL.pdf: 7373323 bytes, checksum: 4741d1f9d635d1e4879a2cd520afb7ae (MD5) / Rejected by Ana Paula Grisoto (grisotoana@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo a orientação abaixo: O arquivo submetido está sem a ficha catalográfica. A versão submetida por você é considerada a versão final da dissertação/tese, portanto não poderá ocorrer qualquer alteração em seu conteúdo após a aprovação. Corrija esta informação e realize uma nova submissão contendo o arquivo correto. Agradecemos a compreensão. on 2016-08-03T13:36:52Z (GMT) / Submitted by PAULA LAZILHA FALEIROS null (paulal.faleiros@hotmail.com) on 2016-08-03T13:55:04Z No. of bitstreams: 1 TESE DE DOUTORADO - PAULA FINAL.pdf: 7377120 bytes, checksum: c55964dddab287b8b096d337e07195bf (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-03T18:08:55Z (GMT) No. of bitstreams: 1 faleiros_pl_dr_araca_par.pdf: 1921873 bytes, checksum: 138048a39be83d82924179cc13951f8c (MD5) / Made available in DSpace on 2016-08-03T18:08:55Z (GMT). No. of bitstreams: 1 faleiros_pl_dr_araca_par.pdf: 1921873 bytes, checksum: 138048a39be83d82924179cc13951f8c (MD5) Previous issue date: 2016-07-05 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo: Avaliar do ponto de vista biomecânico, histomorfométrico, histoquímico e através de marcadores imunoistoquímicos a influência da terapia com laser em baixa intensidade (LLLT) na osseointegração de implantes instalados em tíbias de ratos modificados ou não sistemicamente pela nicotina. Materiais e métodos: Um total de 120 ratos (Wistar) foi distribuído em dois grandes grupos experimentais (n = 60) submetidos a duas aplicações diárias de solução salina (Veh) ou nicotina (Nic). Após 30 dias, implantes de titânio (2.2 mm x 4 mm) foram instalados na metáfise proximal de ambas as tíbias de todos os animais. Grupos experimentais de diferentes tratamentos locais do alvéolo cirúrgico previamente a instalação do implante (n = 30) foram criados no momento da cirurgia: Veh - nenhum tratamento; Veh/LLLT - irradiação do alvéolo cirúrgico com laser em baixa intensidade; Nic - nenhum tratamento; Nic/LLLT - irradiação do alvéolo cirúrgico com laser em baixa intensidade. O laser utilizado foi o Thera Lase (InGaAlP 660 nm, modo de aplicação contínuo, em contato com a área, 35 mW, 0,14 J, 4,9 J/cm2, por 4 segundos). Dez animais de cada grupo foram eutanasiados aos 15, 30 e 60 dias pós-operatórios. As tíbias direitas foram submetidas à análise de torque reverso e posteriormente processadas para confecção de cortes histológicos descalcificados, corados por hematoxilina e eosina, vermelho picrosirius ou submetidos a reações imunoistoquímicas com os anticorpos primários policlonais: HIF-1 α, VEGF, BMP-2, RUNX-2, OCN, ALP, RANKL, OPG e TRAP. A partir das tíbias esquerdas foram preparados cortes histológicos calcificados para análise das porcentagens de contato osso-implante (BIC) e área óssea (BA), dentro dos limites das roscas do implante. A análise foi realizada através da microscopia de luz polarizada para análise histoquímica e da microscopia óptica de campo claro para a análise histológica, histométrica e imunoistoquímicas. As imunomarcações foram submetidas à análise qualitativa para os anticorpos HIF-1 α, VEGF, BMP-2, OCN, ALP, RANKL e OPG e análise quantitativa para os anticorpos RUNX-2 e TRAP. Os dados quantitativos foram analisados estatisticamente (p≤0,05). Resultados: A nicotina atrasou a produção de elementos da matriz óssea, diminuiu o padrão de imunomarcação de HIF-1α, VEGF, BMP-2, OCN, ALP e OPG, aumentou o padrão de imunomarcação de RANKL e aumentou a quantidade de células imunorreativas a RUNX-2 e TRAP, diminuindo a BA, embora não tenha sido capaz de influenciar o torque de remoção e o BIC. O laser aumentou o padrão de imunomarcação de HIF-1α, VEGF, BMP-2, OCN e ALP, aumentou a quantidade de células imunorreativas a RUNX-2 e TRAP, aumentou a BA, mas também não foi capaz de influenciar o torque de remoção e o BIC. Adicionalmente, o laser influenciou positivamente a BA e o torque de remoção dos implantes, aumentou a angiogênese e a diferenciação osteoblástica, promovendo a formação óssea, biomineralização e maturação óssea peri-implantar nos animais modificados sistemicamente pela nicotina. Conclusão: A LLLT é capaz de promover o processo de reparo ósseo peri-implantar em condições normais e compensar os efeitos negativos da nicotina na osseointegração. / Objective: To evaluate, from biomechanical, histomorphometric, histochemical stand point and through of immunohistochemical markers, the influence of low level laser therapy (LLLT) on the osseointegration of implants placed in the tibias of nicotine systemically modified (or not) rats. Materials and methods: A total of 120 rats (Wistar) was assigned into two major experimental groups (n = 60) underwent two-daily-applications of saline (Veh) or nicotine (Nic). After thirty days, titanium implants (2.2 mm x 4 mm) were placed in the proximal metaphysis of both tibiae from all animals. Experimental groups of different surgical alveolus local treatments prior to implant placement (n = 30) were created at the moment of the surgery: Veh - no local treatment; Veh/LLLT - irradiation of surgical alveoli with low level laser; Nic - no local treatment; Nic/LLLT - irradiation of surgical alveoli with low level laser. The laser used was Thera Lase® (InGaAIP 660 nm, in continuous mode, in contact with the area, 35 mW, 0.14 J, 4.9 J/cm2 , for 4 seconds). Ten animals from each group were euthanized at 15, 30 and 60 days postoperative. The right tibiae were submitted to reverse-torque analysis and, then processing in order to prepare decalcified histological sections, stained either by hematoxylin and eosin or picrosirius red or subjected to immunohistochemical reactions with the primary polyclonal antibodies: HIF-1 α, VEGF, BMP-2, RUNX-2, OCN, ALP, RANKL, OPG and TRAP. From left tibias were prepared undecalcified histological sections to evaluate the percentages of bone-to-implant contact (BIC) and bone area (BA) within the limits of the implant threads. The histochemical analysis was performed by a polarized light microscopy and the histological, histometric and immunohistochemical analysis were performed by a bright field optical microscopy. The HIF- 1α, VEGF, BMP-2, OCN, ALP, RANKL and OPG immunostaining were submitted to qualitative analysis and the RUNX-2 and TRAP immunostaining were submitted to quantitative analysis. Quantitative data were analyzed statistically (p≤0.05). Results: The nicotine delayed the production of bone matrix components, decreased the imunolabeling pattern of HIF-1α, VEGF, BMP-2, OCN, ALP and OPG, increased the imunolabeling pattern of RANKL, increased the amount of RUNX-2 and TRAP-immunoreactive cells, reduced the BA, but did not influence the BIC and the force required to break the osseointegration. The laser increased the imunolabeling pattern of HIF-1α, VEGF, BMP-2, OCN and ALP, increased the amount of RUNX-2 and TRAP-immunoreactive cells, increased the BA, but also was not be able to influence the BIC and the force required to break the osseointegration. In addition, the laser positively influenced the BA and the implant removal torque, increased the angiogenesis and osteoblast differentiation, promoted bone formation, biomineralization and peri-implant bone maturation in the nicotine systemically modified rats. Conclusions: LLLT is able to promote the peri-implant bone repair process in normal conditions and is able to compensate the negative effects of nicotine on osseointegration. / FAPESP: 2013/11863-0
563

The educational psychological effect of the cochlear implant on the hearing-impaired child's family

Bezuidenhout, Elsie Petronella 01 1900 (has links)
The cochlear implant represents a radical intervention in the hearing-impaired child's life, which has a profound influence on the feelings and emotions of the child's family. In this study it is endeavoured to identify and to describe this influence. A literature study was done. Families of implanted children in Scotland and in South Africa filled in questionnaires and interviews were held. This study illuminates the fact that parents suffer stress and have various concerns before as well as after the implant. Different reasons why parents decide to give their child a cochlear implant are described. The researcher came to the conclusion that the implanted child functions in a more balanced way and that parents are very satisfied after the implantation. The effect of the implant is described under the following categories: communication, feelings of parents, effect on the deaf child, normality, effect on parents, effect on siblings. / Education / M.Ed.(Guidance and Counselling)
564

Processamento temporal e resposta auditiva de média latência em idosos candidatos e usuários de prótese auditiva / Temporal processing and middle latency auditory response in elderly candidates and hearing aid users

Pinheiro, Maria Madalena Canina [UNIFESP] 22 February 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-22 / Introdução: O envelhecimento pode ocasionar alterações no processamento temporal e nas funções cognitivas. A avaliação eletrofisiológica tem sido recomendada para complementar a avaliação comportamental do processamento auditivo. Objetivo: Verificar e comparar as respostas auditivas comportamentais de processamento temporal e resposta de média latência com o processamento cognitivo em idosos, candidatos e novos usuários de próteses auditivas. Métodos: Participaram do estudo 60 idosos, sendo 20 sexo masculino e 40 sexo feminino, cuja faixa etária era 61 a 85 anos (média 71,7 anos), atendidos no Núcleo Integrado de Assistência, Pesquisa e Ensino da Audição (NIAPEA) da Escola Paulista de Medicina da Universidade Federal de São Paulo, todos novos usuários de prótese auditiva. Os indivíduos foram reunidos em dois grupos segundo o grau da perda auditiva, ao considerar as frequências de 500 a 4000 Hz do audiograma, denominados de Grupo I (GI) e Grupo II (GII). No GI os indivíduos apresentavam grau de perda auditiva inferior ou igual a 50 dB, e no GII, superior ou igual a 51 dB. Os aspectos cognitivos foram avaliados por meio do Potencial Evocado Auditivo de Longa Latência – P300, Mini-Exame do Estado Mental (MEEM) e Escala de Avaliação da Doença de Alzheimer (ADAS-COG). Os procedimentos selecionados para contemplar os objetivos foram o Potencial Evocado Auditivo de Média Latência (PEAML), no qual foi estudada a latência das ondas Na e Pa (milissegundos), amplitude do complexo Na-Pa (microvolts) e quando ocorreu a presença de efeito auditivo e/ou eletrodo o exame foi considerado alterado. Ainda, foram aplicados o Teste Padrão de Duração (TPD) e Teste de Detecção de Gap no Ruído (GIN) no qual foram analisadas as respostas de identificação correta, e o limar de acuidade temporal. Resultados: Os idosos usuários de prótese auditiva apresentaram menor limiar de acuidade temporal, maior reconhecimento de gaps e de discriminação do padrão de duração, menor latência e diminuição das alterações do PEAML em relação ao momento em que eram candidatos. Quando mostravam déficits no processamento da informação em área auditiva primária, apresentaram prejuízo na habilidade auditiva de resolução temporal, que piorava na presença de alteração cognitiva. Conclusão: Houve deterioração das habilidades de resolução e ordenação temporal, independente do grau da perda auditiva, mostrando o efeito- idade originado pelo envelhecimento. As respostas do Potencial Evocado de Média Latência também não foram influenciadas pelo grau da perda auditiva e ocorreu mudança significativa na reavaliação após a aclimatização. Assim, o efeito de estimulação acústica pelo uso de prótese auditiva melhorou a habilidade auditiva de ordenação temporal, resolução temporal e o processamento das informações do Sistema Nervoso Auditivo Central até o córtex temporal primário. O comportamento de ordenação temporal não se modificou nos idosos com alterações cognitivas, no entanto indivíduos sem alteração cognitiva têm menor déficit na integridade funcional das áreas auditivas primárias e melhora no comportamento de resolução temporal. / Introduction: Aging can cause alterations in temporal processing and cognitive functions. Electrophysiological evaluation has been widely recommended to complement the behavioral evaluation of auditory processing. Objective: Verify and compare the behavioral auditory responses of temporal processing and the auditory middle latency response with cognitive processing in elderly candidates for and users of hearing aids. Methods: Sixty elderly people participated in the study, 20 males and 40 females, ranging in age from 61 to 85 (avg. 71.7) who are attended at the Integrated Hearing Assistance, Research and Education Center (NIAPEA) of the Federal University at São Paulo, and who are all new users of hearing aids. The individuals were organized in two groups according to their degree of hearing loss, considering frequencies of 500- 4000 Hz on the audiogram, denominated Group I (GI) and Group II (GII). In GI, the individuals had a degree of hearing loss lower than 50 dB and in GII above 50 dB. The cognitive factors were evaluated by means of long-latency auditory evoked potential tests– P300, Mini mental state examination (MMSE) and the Alzheimer Disease Assessment Scale (ADAS-COG). The procedures selected to achieve the objectives were the Middle Latency Auditory Evoked Potentials (MLAEP) tests, which studied the latency of the Na and Pa waves in milliseconds, and the amplitude of Na-Pa (μv). When an auditory and or electrode effect was present, the exam was considered altered. The Duration Pattern Tests (TPD) and Gap in Noise (GIN) test were used to analyze the responses of correct identification, and the gap detection threshold. Results: Elderly people who use hearing aids display a lower gap detection threshold, greater recognition of gaps and of discrimination of the duration pattern, lower latency and decrease in MLAEP in relation to the time when they were candidates. When they displayed deficits in information processing in auditory cortex, they displayed losses in the temporal resolution ability, which became worse in the presence of cognitive alteration. Conclusion: The temporal ordering and temporal resolution abilities deteriorated independent of the degree of hearing loss, revealing the age effect. The responses to Middle Latency Auditory Evoked Potentials tests were not influenced by the degree of hearing loss and significant changes in reassessment occurred after acclimatization. Thus, the effect of acoustic stimulation by the use of a hearing aid improved the hearing ability of temporal ordering, temporal resolution and the processing of information from the Central Auditory Nervous System to the primary auditory cortex. The behavior of temporal ordering did not change in the elderly with cognitive alterations; however, individuals without cognitive alterations had lower deficits in the functional integrity of the primary hearing areas and improvement in the behavior of temporal resolution. / TEDE / BV UNIFESP: Teses e dissertações
565

Análise de materiais para sistemas de fechamento ósseo através da caracterização superficial e comportamento mecânico

Estambasse, Eduardo Costa [UNESP] 19 May 2015 (has links) (PDF)
Made available in DSpace on 2016-01-13T13:27:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-05-19. Added 1 bitstream(s) on 2016-01-13T13:31:00Z : No. of bitstreams: 1 000846960.pdf: 3346900 bytes, checksum: 6c18e59b1faa366606936b934172298a (MD5) / Neste trabalho busca-se observar um estudo de caracterização mecânica em materiais destinados a implantes, a caracterização superficial dos corpos de provas usinados dos três tipos de materiais utilizados nos implantes para fechamento ósseo titânio grau cinco, titânio grau quatro e aço inox 316 L, estes três tipos de materiais são considerados como biomateriais pois possuem todas as propriedades necessárias para reconstrução óssea, e tem provado ser eficiente para implantes. Este estudo se dará através da aplicação detalhada de ensaios de caracterização superficial e propriedades mecânicas. Um estudo da rugosidade dos materiais antes do implante e a determinação do módulo de cisalhamento e elasticidade utilizando um método não destrutivo foram utilizados. Será apresentado uma síntese dos diferentes tipos de fixação e comparados aos resultados dos ensaios nos materiais. Nos materiais usinados em formatos de discos, foram coletadas imagens num mmicroscópio confocal, e foi realizada análise da superfície com a finalidade de obtenção da rugosidade média quadrática de cada material a fim de identificar a melhor condição de superfície. Uma revisão de literatura fundamentará o estudo proposto / In this work the aim is to observe a mechanical characterization study materials for implants, the surface characteristics of the machined test samples of three types of materials used in bone implants for closing five grade titanium, and titanium grade for stainless steel 316 L, there three types of materials are considered as biomaterials because they posses the necessary properties for bone reconstruction, and has proven to be efficient for implants. This study will be through the detailed application of surface characterization and mechanical properties testing. A study of the roughness of the material before implantation and determining the shear modulus and elasticity using a non-destructive method were used. A summary of different types of fasteners and compared to the test results on the materials will be presented. In machined materials dise formats, images were collected on a confocal microscope, and surface analysis was performed for the purpose of obtaining the mean roughness and mean square surface roughness in order to identify the best surface condition. A literature review reasons or the proposed study
566

Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares

Carvalho, Helen Ramon Esper de [UNESP] 04 September 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-09-04. Added 1 bitstream(s) on 2016-02-05T18:34:21Z : No. of bitstreams: 1 000857959.pdf: 2588157 bytes, checksum: e2c7920ee93dc1516ef1b9eceaece7bd (MD5) / Introdução: A utilização de biomateriais em reconstruções para implantodontia tem sido amplamente discutida nos últimos anos. Proposição: O objetivo deste trabalho foi analisar o comportamento biológico do vidro bioativo (Biogran®) e do osso bovino (Endobon®) durante o processo de osseointegração associados a implantes com defeitos periimplantares em tíbias de rato. Material e método: Foram instalados 75 implantes na tíbia esquerda de 75 ratos Wistar machos. Os implantes foram divididos em três grupos experimentais. No Grupo 1 (Controle) foi provocado um defeito periimplantar monocortical circular e os implantes foram inseridos e deixados apenas com coágulo. No Grupo 2 os implantes foram inseridos com o mesmo defeito ósseo e o espaço preenchido com Biogran® e no Grupo 3 o espaço entre osso e implante foi preenchido com Endobon®. Os animais foram submetidos à eutanásia aos 14 e 42 dias e realizaram-se as análises histológica, histométrica (porcentagem de extensão linear de contato osso-implante - BIC e área óssea - BA), imunoistoquímica (expressão das proteínas osteocalcina - OC e osteopontina - OPN) e biomecânica (torque reverso). Resultados: Histologicamente todos os implantes encontraram-se osseointegrados. Não foram observadas diferenças estatisticamente significantes nos valores de torque reverso (p> 0,05) aos 42 dias. Para BIC, aos 14 dias foi de 8,29; 15,04; e 16,20%, para os grupos 1, 2 e 3, respectivamente. Aos 42 dias, os valores médios de BIC foram 30,84; 33,13; e 13,93% para os mesmos grupos, demonstrando que não houveram diferenças estatísticas entre grupos, porém com respostas diferentes entre períodos. Para a quantificação de formação óssea por área (BA), a resposta entre grupos difere. A resposta da BA média do Grupo 1 (18,75%) não difere da resposta média do Grupo 3 (21,62%). Porém, difere... / Introduction: The use of biomaterials in reconstructions for dental implants has been widely discussed in recent years. Proposition: The aim of this work was to analize the biological behavior of the bioactive glass (Biogran®) and bovine bone (Endobon®) during the osseointegration process associated with implants with peri-implant defects in rat tibia. Material and Methods: 75 implants were installed in the left tibia of 75 male Wistar rats. The implants were divided into three experimental groups. In Group 1 (Control) was caused monocortical circular peri-implant defect and the implants were inserted and left only with clot. In Group 2 implants were inserted with the same bone defect and the space filled with Biogran® and in Group 3 the space between bone and implant was filled with Endobon®. The animals were euthanized at 14 and 42 days and there were the histological analysis, histometric (percentage of linear extension bone-implant contact - BIC and bone area - BA), immunohistochemistry (expression of the proteins osteocalcin - OC and osteopontin - OPN) and biomechanics (reverse torque). Results: Histologically all implants were osseointegrated. No statistically significant differences were observed in the values of reverse torque (p> 0.05) at 42 days. For BIC, at 14 days was 8.29; 15.04; and 16.20% for the groups 1, 2 and 3, respectively. After 42 days, the BIC values were 30.84; 33.13; and 13.93% for the same groups, demonstrating that there were no statistical differences between groups, but with different responses between periods. For the quantification of bone formation per area (BA), the response differs between groups. The average BA response in Group 1 (18.75%) did not differ from the average Group 3 response (21.62%). However, different from Group 2 (34.73%). The immunohistochemical results were analyzed by Qualitative...
567

Estudo comparativo entre as esferas de silicone gelatinosas e rígidas em cavidade eviscerada de coelho

Kanamura, Mayumi Shirota [UNESP] 26 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-26Bitstream added on 2014-06-13T19:53:33Z : No. of bitstreams: 1 kanamura_ms_me_botfm.pdf: 2849170 bytes, checksum: 08cc2f979c93a13d548fc6f0228e430f (MD5) / Universidade Estadual Paulista (UNESP) / Apesar da existência de inúmeros tipos de implantes para reposição de volume em cavidades anoftálmicas, até o momento, nenhum deles pode ser considerado ideal, o que faz com que seja necessário continuar buscando novas soluções. Avaliar a biocompatibilidade de esferas de silicone gelatinosas e rígidas, quando colocadas em cavidades evisceradas de coelhos, comparando-as. Estudo prospectivo e experimental, no qual foram utilizados 30 coelhos albinos, espécie Orictolagus cuniculus, submetidos à cirurgia de evisceração do olho direito, sendo feita a colocação de esferas de silicone gelatinosas ou rígidas na cavidade escleral. Os animais foram sacrificados sete, 30 e 90 dias após a colocação das esferas. Os parâmetros avaliados foram: avaliação clínica diária, ultrassonografia da cavidade eviscerada 15 dias após o procedimento, análise histológica do conteúdo orbitário sete, 30 e 90 dias após a cirurgia, com análise morfométrica da pseudocápsula que se formou ao redor das esferas. Os resultados obtidos foram submetidos à avaliação estatística para comparação dos resultados entre e dentro dos grupos experimentais. Durante o seguimento, ocorreram três extrusões de esferas, duas das quais pertencentes ao grupo das esferas rígidas e uma, do grupo das esferas gelatinosas. O exame ultrassonográfico mostrou ausência de coleções ou processo inflamatório ao redor das esferas e boa integração das mesmas com os tecidos orbitários. Ao exame histológico observou-se semelhança de resposta tecidual com ambas as esferas. O exame morfométrico apontou para superioridade das esferas gelatinosas no tocante a espessura da pseudocápsula, que foi menos espessa, principalmente na avaliação feita no setor posterior da cavidade escleral. Todos os parâmetros estudados mostraram que as esferas de silicone... / Despite the existence of many types of implants for volume replacement in anophthalmic sockets, so far, none can be considered ideal implant, which makes it necessary to continue searching for new solutions. To evaluate the biocompatibility of soft and rigid silicone spheres placed in scleral cavities of eviscerated rabbits, comparing them. Prospctive and experimental study using 30 rabbits, specie Orictolagus cuniculus, underwent evisceration surgery of the right eye and replacement of orbital volume with spheres composed by gelatinous (soft) or rigid silicone. The animals were sacrificed seven, 30 and 90 days after surgery. The studies parameters were: daily clinical assessment, ultrasound of the orbit 15 days after the procedure, histological analysis of the orbital contents seven, 30 and 90 days after surgery and morphometric evaluation in the pseudocapsule in all the animals. Statistical analysis for comparison between and within groups was done. During follow-up occurred three spheres extrusions, two of which belonging to the group of rigid spheres and one from gelatinous sphere group. Ultrasound examination showed no inflammation or collections around spheres and good integration with the orbital tissues. The histological evaluation proved both materials had similar response and the morphometric evaluation showed thinner pseudocapsule formation around the gelatinous sphere, mainly in the posterior scleral region. All the parameters evaluated showed both spheres had good tecidual integration to the orbital tissue in rabbit eviscerated eyes. Therefore, gelatinous silicone sphere induced thinner psedudocapsule formation. The authors agree the gelatinous silicone spheres might be helpful to be used... (Complete abstract click electronic access below)
568

Reparo ósseo em defeito peri-implantar com e sem associação de enxerto ósseo autógeno obtido por Piezocirurgia: estudo experimental em coelhos

Homsi, Nicolas [UNESP] 22 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-22Bitstream added on 2014-06-13T19:40:59Z : No. of bitstreams: 1 homsi_n_dr_araca.pdf: 690157 bytes, checksum: 4f4e024d5301db266278d9736fbf0050 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição: A proposta deste estudo foi avaliar por análise histométrica a resposta tecidual óssea de enxerto autógeno coletado por piezocirurgia para o preenchimento de defeitos nas porções cervicais de implantes instalados em tíbias de coelhos. Métodos: Foram instalados 26 implantes em 13 tíbias de coelho, após a estabilidade inicial foram realizados defeitos cervicais por trefinagem, em um grupo foi mantido apenas o coágulo como preenchimento e em outro grupo o defeito foi preenchido por osso autógeno coletado por equipamento piezoelétrico, os animais foram sacrificados após 15 e 30 dias, a análise histométrica das interfaces implante-osso foram realizadas pelo software Image Lab. Resultados: Foi analisado o percentual de extensão linear de contato entre tecido ósseo e implante, a média percentual obtida de contato entre tecido ósseo neoformado e implante foram estabelecidas como médias da área de osso neoformado entre as espiras e contato osso-implante (BIC). Os resultados obtidos foram: no controle de 15 dias, o percentual entre as espiras foi de 65,2% e entre as espiras e contato osso-implante (BIC) de 88,7%. No controle de 30 dias o contato entre as espiras foi na ordem de 65,2% e entre as espiras e contato osso-implante (BIC) de 73,2%. No grupo de enxerto de 15 dias, o osso formado entre as espiras foi de 69,3% e entre as espiras e contato osso-implante (BIC) em 81%, no grupo enxerto 30 dias o osso formado entre as espiras foi de 91,47% e entre as espiras e contato ossoimplante (BIC) 91,56%. Conclusão: o enxerto ósseo autógeno particulado obtido por piezocirurgia apresenta melhor resultado que o coágulo sanguíneo no osso neoformado entre as espiras e no contato osso-implante / Purpose: The purpose of this study was to evaluate by histometric analysis the outcome of autogenous bone collected through piezo surgery equipment in filling cervical portion defects around implants placed in rabbits tibias. Materials and Methods: Twenty-six implants were installed in 13 rabbits tibias, after initial primary stability, cervical defects were carried out by the use of a trephina, in one group the cloth was maintained as the defect filling and in another group the defect was filled by autogenous bone collected through piezo surgery equipment, the animals were sacrificed after 15 and 30 days, the histometric analysis of the implant-bone interfaces were carried out by the use of Image Lab software. Results: The lineal stretch percentage of contact between bone and implant was analyzed, the average percentage obtained in the contact between the newly formed bone and the implant was established as the average area of the newly formed bone in the space between the spires and the bone-implant contact (BIC). The results obtained were: in the 15-days control group, the percentage of bone formation between the spires was of 65.2% and between the spires and boneimplant contact (BIC) was of 88.7%. In the 30-days control group the contact between the spires was of 65.2% and between the spires and bone-implant contact (BIC) of 73.2%. In the 15-days control grafted group, the formed bone between the spires was of 69.3% and between the spires and bone-implant contact (BIC) of 81%, in the 30-days control grafted group, the formed bone between the spires was of 91.47% and between the spires and bone-implant contact (BIC) of 91.56%. Conclusions: the autogenous bone collected through piezo surgery equipment showed better results than the blood clot regarding the newly formed bone between the spires and bone-implant contact (BIC)
569

Avaliação de substitutos ósseos em defeitos peri-implantares criados em coelhos

Santos, Pâmela Letícia dos [UNESP] 28 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-28Bitstream added on 2014-06-13T20:41:19Z : No. of bitstreams: 1 santos_pl_dr_araca.pdf: 1518173 bytes, checksum: 780aa208fda4e1610407dd0ff2ab5be9 (MD5) / Objetivo: Avaliar a efetividade dos substitutos ósseos, matriz de osso bovino mineralizada – (Bio-Oss®) e matriz de osso bovino mineralizada com adição de 10% de colágeno suíno – (Bio-Oss® Collagen), no preenchimento de defeitos peri-implantares criados em tíbia de coelhos, por meio das análises biomecânica, histológica e imunoistoquímica para a expressão das proteínas OC, Runx 2, OPG, RANK-L e TRAP . Material e Métodos: Trinta coelhos receberam 1 ostectomia em cada tíbia por meio de trefina de 6.1 mm de diâmetro. Em seguida, foram utilizadas as fresa lança e helicoidais no preparo de leitos receptores com 3,0mm e 1 implante de 4,1 mm/8,5 mm foi instalado. Os defeitos ósseos peri-implantares foram preenchidos de acordo com os seguintes grupos: I- coágulo sanguíneo (CO); II- Bio-Oss® (BI); e III- Bio-Oss® Collagen (BC). Dez animais por período foram eutanasiados aos 15, 30 e 60 dias pós-operatórios, para as análises biomecânica, histológica e imunoistoquímica. Resultados: Na análise biomecânica, pode-se observar que o grupo BC apresentou melhor resposta, estatisticamente significante, quando comparado ao CO, no período de 30 dias. Os resultados imunoistoquímicos mostraram na comparação entre os 3 grupos a expressão da OC foi diferente estatisticamente nos períodos de 15 e 60 dias entre os grupos CO e BC; e CO e BI, respectivamente, observando maior expressão para o grupo dos biomateriais aos 15 dias. A expressão de Runx2 foi menor estatisticamente para o grupo BI quando comparado aos demais grupos, no período de 15 dias. Aos 60 dias, a expressão de OPG no grupo BI se apresentou estatisticamente maior que o grupo CO. Nos períodos de 15 e 60 dias, pode-se observar maior expressão de RANK-L... / Objective: To evaluate the effectiveness of bone substitutes in peri-implant defects created in tibia of rabbits which were filled either by blood clot, deproteinized bovine bone mineral (Bio-Oss® / Geistlich) and bovine bone mineral with the addition of 10% collagen porcine origin (Bio-Oss Collagen® / Geistlich), through biomechanics, histology and immunohistochemical analysis of OC, Runx 2, OPG, RANK-L and TRAP proteins. Material and methods: Thirty rabbits received one osteotomy in each tibia using trefine of 6.1 mm in diameter. Subsequently, a spear and helical drills, 2.0 mm, 2.0/3.0 pilot and 3.0 mm were used and 1 implant 4.1 mm/8.5 mm was installed. Bone defects were filled according to the following groups: I-blood clot (CO); II-deproteinized bovine bone mineral (Bio-Oss®) (BI); III-bovine bone mineral with addition of 10% collagen porcine origin (Bio-Oss Collagen®) (BC). Ten animals per period were euthanized at 15, 30 and 60 postoperative days, subsequently biomechanical analysis were performed. Routine histologic processing for histological and immunohistochemistry analysis were also performed. Results: In biomechanics analysis, comparing the different groups for each period can be observed that within 30 days, the BC group showed better biological response statistically proven compared to CO. In immunohistochemistry analysis, the OC expression was statistically significant at 15 and 60 days between CO and BC groups, and between CO and BI groups, respectively, with largest expression for the group of biomaterials. In these same analysed periods, an increased expression of RANK-L can be observed on BI group compared to CO group. OPG expression was statistically significant only iat 60 postoperative days for BI group... (Complete abstract click electronic access below)
570

Regeneração óssea de defeitos circunferenciais criados cirurgicamente ao redor de implantes submersos. Estudo experimental em cães

Rossi, Fabio [UNESP] 06 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-06Bitstream added on 2014-06-13T19:22:09Z : No. of bitstreams: 1 rossi_f_dr_araca.pdf: 2781899 bytes, checksum: c7a4e989b92a1d7cf3f24753f22ce3c4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: descrever o processo de reparo em defeitos marginais ao redor de implantes submersos 1mm abaixo ou acima da crista óssea. Estudo experimental em cães. Material e Métodos: Em 12 cães labradores, todos os pré-molares inferiores e primeiros molares foram extraídos bilateralmente. Três meses após as extrações, foi realizada a incisão sobre o rebordo e o descolamento dos retalhos de espessura total do lado direito da mandíbula. Foram preparados dois sítios cirúrgicos para instalação de implantes, com a região marginal alargada em 5mm de diâmetro para obtenção de um gap de 0,5 mm na região mesial (defeito pequeno) e um gap de 1,25 mm na região distal (defeito grande). Os parafusos de cobertura foram colocados aos implantes e os retalhos suturados para permitir um processo de cicatrização totalmente submerso. Posteriormente, foram realizados os mesmos procedimentos experimentais no lado esquerdo da mandíbula. O momento da realização dessas cirurgias e as eutanásias foram planejados de forma a se obter biópsias com 5, 10, 20, 30 dias de pósoperatórios. Após a eutanásia, os cortes histológicos foram processados laboratorialmente para análise histomorfométrica. Resultados: Aos 30 dias pós-operatório, os defeitos ósseos apresentaram-se parcialmente preenchidos por osso neoformado em todos os espécimes. A formação óssea ocorreu originando-se a partir da base do defeito e das paredes laterais. Um maior volume de osso neoformado foi observado nos defeitos grandes quando comparado aos pequenos. A maior parte de osso neoformado nos defeitos grandes formou-se entre o décimo e vigésimo dias de pósoperatórios. Entretanto, o contorno do osso neoformado localizou-se a uma distância similar da superfície do implante (aproximadamente 0,4 mm) em ambos os tipos de defeitos, no... / Objective: to describe the healing of marginal defects below or above one millimeter of dimension around submerged implants in a dog model. Material and Methods: In 12 Labrador dogs, all mandibular premolars and first molars were extracted bilaterally. After 3 months of healing, full-thickness flaps were elevated in the edentulous region of the right side of the mandible. Two recipient sites were prepared and the marginal 5 mm were widened to such an extent to obtain, after implant installation, a marginal gap of 0.5 mm at the mesial site (small defect) and of 1.25 mm at the distal site (large defect). Titanium healing caps were affixed to the implants and the flaps were sutured allowing a fully-submerged healing. The experimental procedures were subsequently performed in the left side of the mandible. The timing of the experiments and sacrifices were planned in such a way to obtain biopsies representing the healing after 5, 10, 20, 30 days. Ground sections were prepared and histomorphometrically analyzed. Results: The filling of the defect with newly formed bone was incomplete after one month of healing in all specimens. Bone formation occurred from the base and the lateral walls of the defects. A larger volume of new bone was formed in the large compared to the small defects. Most of the new bone at the large defect was formed between the 10 and the 20-day period of healing. After one month of healing, the outline of the newly formed bone was, however, located at a similar distance from the implant surface (about 0.4 mm) at both defect types. Only minor newly formed bone in contact with the implant, starting from the base of the defects, was seen at the large defects (about 0.8 mm) while a larger amount was detected at the small defects (about 2.2 mm). Conclusion: Marginal defects around titanium... (Complete abstract click electronic access below)

Page generated in 0.0796 seconds