• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 833
  • 523
  • 82
  • 45
  • 31
  • 24
  • 21
  • 21
  • 20
  • 20
  • 19
  • 17
  • 13
  • 12
  • 11
  • Tagged with
  • 1885
  • 853
  • 745
  • 493
  • 257
  • 239
  • 196
  • 185
  • 175
  • 148
  • 141
  • 134
  • 133
  • 128
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
581

Análise microbiológica da exposição das roscas dos implantes osseointegráveis no seio maxilar de ovelhas

Gaujac, Cristiano [UNESP] 27 August 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-08-27Bitstream added on 2015-05-14T16:58:43Z : No. of bitstreams: 1 000821516_20171002.pdf: 41220 bytes, checksum: 3aecccde9e4b5dfb57d56d2ef79aa29e (MD5) Bitstreams deleted on 2017-10-09T13:25:03Z: 000821516_20171002.pdf,. Added 1 bitstream(s) on 2017-10-09T13:26:06Z : No. of bitstreams: 1 000821516.pdf: 288180 bytes, checksum: 5a8b4e07a45af397ecf7ea4a019e230a (MD5) / Objetivo - O objetivo desse trabalho é avaliar a alteração microbiológica com a exposição de expiras de implantes dentários dentro do seio maxilar. Materiais e métodos - O experimento se passa por duas etapas onde foram utilizadas oito ovelhas. Na primeira fase foram realizados swabs nos seios maxilares por via extra oral imediatamente seguida pela colocação de um implante em cada seio maxilar pela mesma via. No lado direito o implante tinha a superfície tratada e do lado esquerdo a superfície foi usinado. Na segunda etapa, realizada três meses após a primeira, o swab na mucosa foi refeito e foi realizado um esfregaço na superfície do implante com um microbrush estéril. Os meios de cultura utilizados foram: ágar sangue, ágar chocolate, ágar Mac Conkey, ágar sal manitol e ágar Sabouraud. A análise estatística foi realizada com os testes T student, binomial e Exato de Fisher. Resultados - Na primeira etapa a amostra apresentou 37.5% dos seios com crescimento positivo passando para 50% na segunda etapa e com 80% dos implantes inseridos colonizados por microrganismos. Após três meses da colocação dos implantes houve uma proliferação de Staphylococcus aureus e um crescimento significativo de leveduras (test T student, p = 0.0413) com edema importante da mucosa do seio maxilar apesar de não apresentar nenhum sinal clínico de infecção, dois implantes usinados não osseointegraram. Não houve diferença significativa entre os implantes usinados e com superfície tratada na colonização de microrganismos. Conclusão - A exposição de implantes ao seio maxilar propicia uma proliferação de Staphilococcus aureus e fungos e não houve diferença entre implantes de superfície tratada com implantes usinados na colonização de microrganismos. / Aim - The purpose of this study is to evaluate the microbiological changes with exposure expiras of dental implants in the maxillary sinus. Materials and methods - The experiment goes through two stages where eight sheep were used. In the first phase swabs were performed in the maxillary sinuses for pathway extra orally immediately followed by the placement of an implant in each maxillary sinus via the same pathway. On the right side the implant had the treated surface and the left surface has been machined. In the second stage, performed three months after the first, the in the mucosa swab was redone and a smear was performed at the implant surface with a sterile microbrush. The culture media used were blood agar, chocolate agar, MacConkey, mannitol salt agar and Sabouraud agar. Statistical analysis was performed using the Student t test, Fisher and Binomial. Results - In the first stage of the study showed 37.5% of breasts with positive growth rising to 50% in the second stage and 80% of the placed implants colonized by microorganisms. Three months after implant placement has been a proliferation of Staphylococcus aureus and significant growth of yeasts (student t test, p = 0.0413) with significant edema of the mucosa of the maxillary sinus despite not presenting any clinical signs of infection, two machined implants do not osseointegraram. There was no significant difference between the machined surface implants and treated with the colonization of microorganisms. Conclusion - Exposure of implants to the maxillary sinus provides a proliferation of Staphylococcus aureus and fungi and there was no difference between the treated surface machined in the colonization of microorganisms implants.
582

Avaliação da prevalência das doenças peri-implantares e do sucesso e sobrevivência de implantes osseointegrados com 8 a 10 anos de função

Marcantonio, Claudio [UNESP] 15 July 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:33:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-15. Added 1 bitstream(s) on 2015-06-18T12:48:15Z : No. of bitstreams: 1 000829732.pdf: 254395 bytes, checksum: 2c5cde2b99d99ee75bc615c0df3e6e55 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito deste estudo retrospectivo foi verificar as taxas de sucesso e sobrevivência de implantes osseointegrados no longo prazo, assim como determinar a prevalência de doenças peri-implantares e identificar possíveis fatores de risco associados à ocorrência da peri-implantite. A amostra foi constituída de 50 pacientes parcialmente desdentados que realizaram reabilitações sobre implantes osseointegrados no período de 2003 a 2005. As avaliações incluíram a coleta de informações demográficas, sistêmicas e comportamentais, além de exames clínicos e radiográficos para avaliação da condição periodontal e peri-implantar. Uma análise multivariada foi adotada para identificar possíveis preditores de risco para a periimplantite. Um total de 211 implantes foram instalados nestes pacientes. Cinco implantes foram perdidos e 9 implantes encontravam-se submersos, ou seja, sem função. Assim, 197 implantes em 48 pacientes foram avaliados clinicamente. A prevalência de mucosite foi de 77,1% a nível de paciente e 52,3% a nível de implante. A peri-implantite foi diagnosticada em 25 implantes em 14 pacientes. As taxas de sucesso e de sobrevivência encontradas foram de 82% e de 97,6%, respectivamente. A presença de osteoporose (OR = 2,87) e a presença de sangramento à sondagem (SS) de boca toda ≥ 30% dos sítios (OR = 8,03) foram variáveis relacionadas ao indivíduo significativamente associadas com maior ocorrência de periimplantite. A presença de placa visível (OR = 4,45) e a presença de sítios com profundidade de sondagem (PS) ≥ 4 mm (OR = 4,47) foram variáveis relacionadas ao implante significativamente associadas com maior ocorrência de peri-implantite. Apesar da alta taxa de sobrevivência no longo prazo, foi observada uma alta prevalência de mucosite e a peri-implantite foi diagnosticada em 12,7% dos implantes e 29,2% dos pacientes avaliados...(Resumo completo, clicar acesso eletrônico abaixo) / The aim of the present study was to verify the long-term success and survival rates of osseointegrated dental implants, as well to determine the prevalence of peri-implant disease, and to identify potential risk factors associated to the occurrence of peri-implantitis. The sample was comprised of 50 patients who had their implant-supported rehabilitation concluded between the years of 2003 and 2005. Evaluations included the gathering of demographic, systemic and behavioral information, as well as radiographic and clinical records for the assessment of periodontal and peri-implant conditions. Multivariate analysis was employed to identify potential risk factors related to the occurrence of peri-implantitis. A total of 211 implants were installed, out of which 5 were lost and 9 were submerged, that is, nonfunctioning. Thus, 197 implants in 48 patients were clinically evaluated. The presence of osteoporosis (OR = 2,87) and the presence of full-mouth BOP scores ≥ 30% of sites (OR = 8,03) were variables significantly associated with a higher occurrence of peri-implantitis, among the subjects. At the implant level, the presence of visible plaque (OR = 4.45) and the presence of sites with probing depth (PD) ≥ 4 mm (OR = 4.47) were variables significantly associated with a higher occurrence of peri-implantitis. Mucositis prevalence was 77.1% and 52.3%, at subject and implant level, respectively. Periimplantitis was diagnosed in 25 implants (12.7%) and 14 patients (29.2%). Success and survival rates were 82% and 97.6%, respectively. Our results suggest that subjects with osteoporosis and with full-mouth BOP scores ≥ 30% of the sites, as well as implants with visible plaque and sites with PD ≥ 4 mm, are more susceptible to peri-implantitis.
583

Desenvolvimento de parafuso de interferência bioabsorvível para cirurgia de joelho em PLDL (poli ácido lático) e compósito PLDL + βTCP (beta trifosfato de cálcio) / Development of bioabsorbable interference screw for knee surgery in PLDL (poly L,DL-lactic acid) and composite PLDL / βTCP (Beta tricalcium phosphate)

Santos, Alex Eugênio dos [UNESP] 12 January 2015 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-01-12. Added 1 bitstream(s) on 2015-06-18T12:48:27Z : No. of bitstreams: 1 000825246.pdf: 3464292 bytes, checksum: 907652ea25dcfa1a9a30ba9ee22fa099 (MD5) / O parafuso de interferência é o dispositivo de fixação mais usados em cirurgias de reconstrução ligamentar de joelho. O uso dos polímeros bioabsorvíveis está sendo cada vez mais utilizados nesta aplicação, devido suas vantagens relacionadas à excelente biocompatibilidade, bioabsorção, integração do enxerto/osso e também facilidade na revisão cirúrgica. O presente estudo tem por objetivo tem por objetivo o desenvolvimento de um parafuso de interferência bioabsorvível fabricado através do processo de injeção em dois polímeros bioabsorvíveis: PLDL (Poli L-D-ácido lático) e um compósito de PLDL+30% TCP (β Trifosfato de Cálcio). Para o desenvolvimento do projeto do produto foi usado um programa de análise estrutural por elementos finitos, de forma a obter a melhor geometria do encaixe de ferramenta. Através dos estudos de simulação por elementos finitos foi possível selecionar a geometria com maior resistência mecânica levando em conta o esforço de torção e além disso foi possível analisar a influência de furos transversais nas tensões mecânicas geradas pelos esforços de torção. Após a definição da melhor geometria, foram fabricadas amostras dos parafusos com os dois polímeros selecionados, os quais foram esterilizados por ETO (Óxido de etileno). Foram realizados testes mecânicos de torque inserção e torque de ruptura. A resistência mecânica do parafuso foi avaliada através da comparação entre os valores do torque de inserção comparando-se com o torque máximo de ruptura. Para contribuir o estudo foi executado teste de degradação in vitro, durante um período de 180 dias, onde foi avaliada a perda de massa dos implantes, resistência mecânica e queda do peso molecular dos implantes. Logo foi possível avaliar o compartamento mecânico dos implantes em degradação comparando-os com os requerimentos da aplicação. Pode-se observar que a degradação molecular do implante ao longo dos... / The interference screw is the fixation device most selected for Knee ligament reconstruction surgeries. The use of Bioabsorbable polymers in interference screws for this application is increasing due it has advantages like excellent biocompatibility, bioabsorption, good integration between graft / bone and also facility in the surgical revision. The aims of the present study were to develop a bioabsorbable interference screw manufactured by the injection moulding process with two distinct polymeric materials: PLDL, Poly(L,DL-Latic acid) and a composite PLDL + 30% TCP (β Tricalcium phosphate). A program for structural analysis by finite elements was used in the development of the screw design, in the intend to make the best geometry fit for the tool. Trough the study by finite elements simulation it was possible to chose the geometry with higher mechanical resistance taking in the account the torsion effort and analyse the influence of transversals holes in the mechanical tensions made by the torque efforts. After the definition of the best geometry, samples of the screw were manufactured with the two selected polymers, sterilized with ETO (ethylene oxide). Were performed mechanical tests, insertion test and torque to break. The mechanical strenght of the screw was evaluated through the comparison between the values of insertion torque and maximum rupture. In addition, a in vitro, degradation test was performed over a period of 180 year days. It was observed, the weight loss, mechanical strength of the implants was evaluated, and molecular weight drops of the implants. Therefore it was possible to evaluate the mechanical behavior in degradation and compare with the application requirements. It can be observed that the raise of the molecular degradation of the implant along the months had as result a loss of the mechanical resistance of the screw, ina slowly and gradual way for the PLDL material, yet the composite material (PLDL+TCP)...
584

Carbono tipo diamante em componentes de implantes dentários: avaliação das propriedades antimicrobianas e de adesão de Escherichia coli

Maquera Huacho, Patricia Milagros [UNESP] 13 March 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-13. Added 1 bitstream(s) on 2015-06-18T12:47:03Z : No. of bitstreams: 1 000830189_20170313.pdf: 149660 bytes, checksum: 52524b576bd709ce5dfcdfd29e55bc0a (MD5) Bitstreams deleted on 2017-03-17T12:38:06Z: 000830189_20170313.pdf,. Added 1 bitstream(s) on 2017-03-17T12:39:07Z : No. of bitstreams: 1 000830189.pdf: 425234 bytes, checksum: 5b7c2d176991ced4133234bd3048be4d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O estudo de filmes de Carbono tipo Diamante é objeto de pesquisas devido às suas diferentes propriedades incluindo propriedades antibacterianas. No tratamento reabilitador com implantes, podem ocorrer complicações, proporcionando a infiltração de microrganismos orais para a interface Implante-Componente protético. O objetivo deste estudo foi avaliar propriedades de molhabilidade e energia livre de superfície a partir dos valores do ângulo de contato; propriedades antimicrobiana, de bioadesão e citotoxicidade de discos de titânio recobertos com DLC. Escherichia coli foi mantida em meio BHI a 37ºC por 3 h e 24 h para teste antimicrobiano. Para adesão, os discos foram mantidos em cultura de E. coli por 90 minutos a 37ºC e 20 minutos em ultrassom. A capacidade de prevenção na migração de bactérias para o interior da interface Implante-Componente protético foi realizado em implantes Hexágono Externo, conectados com torque de 32N e deixados em contato com E. coli por 24h, e Reação em Cadeia da Polimerase semi-quantitativo foi realizado para confirmação da esterilidade da técnica. Foram quantificados em UFC/mL em BHI Ágar para o teste antimicrobiano, adesão e infiltração bacteriana. Para citotoxicidade foi utilizado queratinócitos humanos (HaCat) cultivados em meio DMEM mantidos em atmosfera com 5% de CO2 a 37°C e avaliados pelo teste colorimétrico MTT. Os resultados de molhabilidade, teste antimicrobiano, teste de adesão e Infiltração bacteriana não apresentaram diferença estatisticamente significante entre os grupos. As superfícies de titânio e recobertas com DLC apresentaram uma leve diminuição na viabilidade celular com diferença estatisticamente significante ao grupo controle. O DLC apresenta-se como material biocompatível com leve grau de citotoxicidade que não modifica as propriedades de superfície, não apresenta propriedades antimicrobianas... (Resumo completo, clicar acesso eletrônico abaixo) / The study of DLC films is the subject of research due to their different properties including antibacterial properties. Rehabilitator in implant treatment, complications may occur, providing the infiltration of oral microorganisms for implant- abutmente interface. The aim of this study was to evaluate properties and wetting surface free energy from the values of the contact angle; antimicrobial properties bioadhesion and cytotoxicity of titanium discs coated with DLC. Escherichia coli was maintained on BHI at 37 ° C for 3 h and 24 h for antimicrobial test. For adhesion test, the discs were maintained in culture of E. coli for 90 minutes at 37 ° C and 20 minutes inside ultrasound. The ability to prevent the migration of bacteria into the implant - abutment interface was performed in dental implants External Hexagon connected with a torque of 32N and left in contact with E. coli for 24 h , and Polymerase Chain Reaction semi -quantitative was performed to confirm the sterility of the technique. Were quantified in CFU / ml in BHI agar for antimicrobial test, bacterial adhesion and infiltration. Cytotoxicity was performed using human keratinocytes ( HaCaT ) cultured in DMEM maintained in an atmosphere of 5% CO2 at 37 ° C and evaluated by the MTT colorimetric assay. The results of wettability, antimicrobial test, adhesion test and bacterial infiltration showed no statistically significant difference between the test groups. The surfaces of titanium and coated with DLC showed a slight decrease in cell viability with a statistically significant difference to the control group. The DLC is presented as biocompatible material with mild cytotoxicity without changing the surface properties, has no antimicrobial properties, does not interfere with bacterial adherence for E. coli and do not inhibit bacterial infiltration into the implant-abutment interface.
585

Estudo das microdeformações geradas ao redor de implantes de hexágono externo, sob a aplicação de cargas axiais e não axiais em pilares protéticos retos e angulados

Rodrigues, Vinícius Anéas [UNESP] 04 November 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-11-04. Added 1 bitstream(s) on 2015-09-17T15:47:42Z : No. of bitstreams: 1 000843387.pdf: 1950465 bytes, checksum: 6efd26a8277df06f6a5ccd400a209b9e (MD5) / O objetivo do estudo in vitro foi avaliar por meio da extensometria as microdeformações em prótese fixa de três elementos sobre implantes de hexágono externo, sob cargas axiais e não axiais e avaliar possíveis correlações com as fendas encontradas nas estruturas metálicas. Foram confeccionados dois blocos de poliuretano, receberam três implantes cada e foram divididos em dois grupos: reto e angulado em 17°. Para mensurar as microdeformações foram colados quatro extensômetros nas superfícies dos blocos, tangenciando cada um dos implantes. Foi utilizado intermediário do tipo microunit para todos os implantes, sendo que os implantes com inclinação de 17° receberam componentes para a correção da angulação. Coifas plásticas foram adaptadas a um enceramento padronizado e depois fundidas. A supraestrutura metálica foi parafusada com torque de 10 N.cm. Utilizou-se do dispositivo de aplicação de cargas (DAC) com uma carga de 30 kgf durante 10 segundos. Os dados obtidos foram submetidos ao ANOVA e Tukey (p< 0,05) e correlacionados com os valores de fenda através da correlação linear de Pearson. Os resultados mostraram que os valores para diferentes inclinações dos implantes foram estatisticamente significantes, sendo (p = 0,0022< 0,05) para os pontos axiais e (p = 0,0012< 0,05) para os pontos não axiais, sendo que o efeito ponto de aplicação de carga (p = 0,0001) obteve valores significantes apenas para os pontos não axiais; os resultados mostraram que não houve correlação entre as microdeformações e as fendas. Concluiu-se que as microdeformações são maiores para os implantes angulados de 17° e para os pontos mais distantes do parafuso de fixação das estruturas, nos pontos não axiais (3 e 5 mm), não foi encontrado correlação entre as fendas e os valores de microdeformação / The aim of this in vitro study was to evaluate by strain gauge analysis, the micro-strain distribution around three elements implant supported partial prosthesis with external hexagon implants on axial and non-axial loading and to evaluate possible correlations with gaps found on the metal structures. Two polyurethane blocks were made, received three implants each and divided in two groups: straight and angled 17°. To measure the micro-strain, four strain gauges were bonded on the surface of the blocks tangentially to every implant. Microunit abutments were used for all implants, and the implants with an inclination of 17°, receiving abutment to correct angulations. Plastic copings were adapted to a standard pattern and cast. The metallic structure was screwed onto the abutments using a 10 Ncm torque. A static vertical load was applied 30kgf for 10 seconds with a load application device. The data were analyzed by ANOVA and Tukey's test (p< 0.05%) and related values gaps through the linear Pearson's correlation test. The results showed that the values for different implant inclinations were significant, (p = 0.0022) for axial points and (p = 0.0012) for non-axial points; whereas the point of application of load (p = 0.0001), obtained significant values only for non-axial points, the results showed no correlation between the micro-deformations and gaps. It was concluded that the micro-deformations are higher for the 17° angled implants and to the farthest points of the fastening screw of the structures in non-axial points (3 and 5 mm); there was no correlation found between the gaps and the values of microstrain
586

Estudo das tensões em próteses sobre implantes esplintadas: análise pelo método da fotoelasticidade

Villa, Luiz Marcelo Ribeiro [UNESP] 10 September 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-09-10Bitstream added on 2014-08-13T18:00:08Z : No. of bitstreams: 1 000764882.pdf: 5546687 bytes, checksum: 876ee1da472cfe331f69881dd5107292 (MD5) / Propósito: O objetivo deste estudo foi avaliar a influência da esplintagem e de diferentes comprimentos de implantes na distribuição de tensões em próteses implantossuportadas, sob carregamento axial e oblíquo, por meio do método da fotoelasticidade. Materiais e métodos: Um total de 05 modelos em resina fotoelástica foi confeccionado com diferentes situações propostas, realizaram-se 400 aplicações de carga para análise. As tensões foram consideradas de forma quantitativa e qualitativa utilizando um método randomizado e simples cego. A reprodutibilidade do estudo foi avaliada usando o coeficiente de correlação intra-examinador (CCI), erro sistemático e erro casual. A análise de variância a três critérios e pós-teste de Tukey foram utilizados e, valor de p>0.05 foi adotado para analisar as principais diferenças. Resultados: As mensurações mostraram elevado coeficiente de concordância intraexaminador (CCI>0.97). A esplintagem de próteses implantossuportadas agiu favoravelmente na distribuição de tensões e na transmissão de tensões para o implante adjacente (p<0.001), quando comparado a próteses unitárias. O carregamento oblíquo foi mais prejudicial e, pontecializou a formação de tensões em implantes adjacentes (p<0.001). O aumento do comprimento foi um fator significante na avaliação dos modelos B e C (p=0.004), o modelo B apresentou maior concentração de franjas quando comparado com D e E (p<0.001). Conclusão: As próteses implantossuportadas esplintadas comportaram-se melhor biomecanicamente quando comparadas as próteses unitárias. O aumento do comprimento teve relevância na redução de tensões. O carregamento oblíquo foi mais prejudicial para a distribuição de tensões quando comparado com o carregamento axial. / Purpose: The purpose of this study was to evaluate the influence of different lengths and splinting of implants on stress distribution in implant-supported prostheses under axial and oblique loading by means of the method of photoelasticity. Materials and methods: 05 models in photoelastic resin was prepared with different proposed situations, there were 400 applications for load analysis. Tensions were considered quantitatively and qualitatively using a randomized, single blind method. The reproducibility of the study was assessed using the intra correlation coefficient, systematic error and random error. The analysis of variance to three criteria and post - Tukey tests were used, and p values > 0.05 was adopted to analyze the main differences. Results: The measurements showed a high intra-concordance coefficient (ICC> 0.97). The prosthetic implant splinting acted favorably in the distribution of stresses and strains in the transmission next to the implant (p<0.001) when compared to the unitary prosthesis. The oblique loading was more damaging and potentialized the formation of stresses in adjacent implants (p<0.001). The increase in length was a significant factor for the evaluation of the models B and C (p = 0.004), the model B had a higher concentration of fringes as compared with D and E (p<0.001). Conclusion: The prosthetic implant splinted behaved better biomechanically compared prosthetics unit. The increased length was important in reducing stress. The oblique loading was more detrimental to the stress distribution compared to axial loading.
587

Reconstrução imediata de diferentes defeitos peri-implantares em implantes pós-exodônticos: análise histomorfométrica em cães

Pereira, Flávia Priscila [UNESP] 06 December 2013 (has links) (PDF)
Made available in DSpace on 2014-08-27T14:36:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-12-06Bitstream added on 2014-08-27T15:57:09Z : No. of bitstreams: 1 000750034_20151206.pdf: 121129 bytes, checksum: 6db018df5ceff35f98c716e2cb23896e (MD5) Bitstreams deleted on 2015-12-07T09:44:41Z: 000750034_20151206.pdf,. Added 1 bitstream(s) on 2015-12-07T09:45:18Z : No. of bitstreams: 1 000750034.pdf: 8693354 bytes, checksum: 974db9f2b05e2b1eaf29e1a4b9764bcd (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo: A proposta deste estudo foi avaliar a regeneração óssea de defeitos criados cirurgicamente e naturais circunferenciais (gap) de implantes pósexodônticos. Materiais e método: Para este estudo foram utilizados 8 cães da raça labrador, nos quais foram instalados implantes imediatos (pós-exodônticos) nos alvéolos dos dentes P2 (2o pré-molar) e M1 (1o molar) inferiores bilaterais. Nos implantes da região dos 2º pré-molares bilaterais foram criados cirurgicamente defeitos peri-implantares vestibulares que foram preenchidos de um lado por osso autógeno – OA e do outro por osso bovino inorgânico Bio-Oss ®- OB. Nos alvéolos correspondentes aos primeiros molares (M1) os implantes foram instalados e os gaps (defeitos naturais) existente entre a tábua óssea vestibular e o implante, foram preenchidos por Bone Ceramic ® - (grupo BC) ou somente coágulo (grupo COA). Todos os sítios cirúrgicos foram posteriormente recobertos por membrana de colágeno reabsorvível (Biogide ®) e mantidos com cicatrizador. Após 4 meses de pós-operatório, os animais foram eutanasiados e os blocos ósseos processados laboratorialmente para análise histomorfométrica. Resultados: Os resultados obtidos nos implantes instalados na região do P2 mostraram que os valores do IS-C foram ligeiramente maior (2.3±0.8mm) no grupo OA, comparado ao grupo OB (1.7± 0.7 mm), enquanto o IS-B dos grupos OA e OB foram respectivamente de 2.7±0.7mm e 2.2±1.0 mm no lado vestibular e de 1.6±0.8mm e 0.8±0.5mm no lado lingual. As médias dos valores de PM-C, PM-B e PM-IS no grupo OA e OB foram respectivamente de 4.3±0.9mm, 4.7±0.9mm, 2.0±1.6mm e 4.3±0.6mm... / Objective: The purpose of these studies were to evaluate bone regeneration at natural or surgically-created buccal defects at implants placed immediately into extraction sockets (IPIES). Material and methods: Eight Labrador dogswere used and implants were placed immediately into the extraction sockets of P2 (second premolar ) and M1 (first molar), bilaterally. At P2, the buccal wall of the extraction sockets was removed bilaterally to create a standardized defect, 4 mm wide coronally, 2 mm wide apically, and 6 mm height. At P2 sites, Bio-Oss at the test (OB) or autogenous bone at the control (OA) sites were used to fill the defects. At M1 sites, Bone Ceramic ® at the test (BC) or the clot alone (COA) were used to fill the defects. All surgical sites were subsequently covered by a resorbable collagen membraneand a non-submerged healing was allowed . After 4 months the animals were euthanized, bone blocks harvested and processed for histomorphometric analysis . Results: at P2 sites, IS- C values were slightly higher (2.3±0.8mm) in the OA compared to the OB (1.7±0.7 mm). IS- B were 2.7 ± 0.7mm and 2.2 ± 1.0mm on the buccal side and 1.6 ± 0.8mm and 0.8 ± 0.5mm on the lingual side at OA and OB groups, respectively. The average values of PM- C , B - PM and PM -IS in OA and OB groups were 4.3 ± 0.9mm , 4.7 ± 0.9mm , 2.0 ± 1.6mm and 4.3 ± 0.6mm , 4.8 ± 0.6mm , 2.5 ± 0.8mm, respectively. A statistically significant difference was only observed in the thickness of the buccal bony crest at 2-5 mm apically to IS (the implant neck) when the biomaterial (S -OCbt )... / FAPESP: 10/15286-9
588

Corrosão e tribocorrosão de novas ligas Ti35Nb5Zr e Ti35Nb10Zr em saliva artificial

Ribeiro, Ana Lúcia Roselino [UNESP] 14 May 2012 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-05-14Bitstream added on 2014-11-10T11:57:36Z : No. of bitstreams: 1 000696703_20151015.pdf: 717026 bytes, checksum: 5355948c5df8f33b19259671ebbacaef (MD5) Bitstreams deleted on 2015-10-16T13:54:04Z: 000696703_20151015.pdf,. Added 1 bitstream(s) on 2015-10-16T13:54:47Z : No. of bitstreams: 1 000696703.pdf: 3192154 bytes, checksum: 9e16a047b017d630b9cc1b50dfe0ff4e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O sucesso dos implantes dentários em longo período depende da interação do biomaterial com o ambiente bucal, a qual envolve reações eletroquímicas, resistência mecânica e desgaste mecânico. Com o intuito de melhorar a resistência mecânica e à corrosão do titânio (Ti), elementos de liga são adicionados, sendo a liga Ti6Al4V a mais comum. Porém, o vanádio e o alumínio são considerados potencialmente tóxicos. Portanto, nos últimos anos, esforços vêm sendo feitos para o desenvolvimento de novas ligas de Ti ultra resistentes e biocompatíveis, a partir do sistema TiNbZr. Assim, o objetivo desse trabalho foi avaliar a corrosão e tribocorrosão das novas ligas Ti35Nb5Zr e Ti35Nb10Zr em saliva artificial a 37°C comparadas à liga comercial Ti6Al4V. Testes de potencial de circuito aberto com o tempo (Ecorr) e espectroscopia de impedância eletroquímica (EIS) foram realizados em função do tempo (0-216h). Testes de tribocorrosão em função de cargas aplicadas (50mN-1N) foram realizados tanto em Ecorr como em potencial anódico aplicado. Como resultados, todas as ligas exibiram aumento de Ecorr com o tempo, indicando crescimento e estabilização do filme passivo. Os experimentos de EIS indicaram que a liga Ti35Nb10Zr possui resistência à corrosão ligeiramente maior que a liga Ti6Al4V, assim como melhor comportamento tribocorrosivo quando realizado com baixa carga. Portanto, o filme passivo formado na liga Ti35Nb10Zr possui melhor resistência à corrosão e ao desgaste devido à presença de Nb2O5 e ZrO2. Porém, o metal base da liga Ti6Al4V apresentou menor desgaste mecânico. Concluindo, a liga de Ti35Nb10Zr é candidata promissora a ser utilizada na fabricação de conjuntos implantes-componentes protéticos. / The long-life success of dental implants relies on the interaction between the biomaterial and oral environment, always involving electrochemical reactions, mechanical stresses and mechanical wear. In order to improve the mechanical strength and corrosion resistance of titanium (Ti), alloying elements are added to it, the most common alloy being Ti6Al4V. However, vanadium and aluminum are known to be toxic. Therefore, in last years, efforts are being made towards the development of new high resistant and biocompatible titanium alloys, namely from the TiNbZr system. Therefore, the aim of this work was to assess the corrosion and tribocorrosion behavior of new Ti35Nb5Zr and Ti35Nb10Zr in artificial saliva at 37°C, in comparison with the commercial Ti6Al4V alloy. Open circuit potential (Ecorr) and electrochemical impedance spectroscopy (EIS) experiments were carried in function of time (0-216h). Tribocorrosion tests were performed at different applied loads (50mN to 1N) both at Ecorr and anodic applied potential. In general, all alloys exhibited an increase of Ecorr with the immersion time, indicating the growth and stabilization of the passive film. The EIS results indicated that Ti35Nb10Zr alloy exhibited slightly better corrosion resistance than Ti6Al4V. Just as better tribocorrosion behavior at low applied loads. Therefore, the passive film formed on Ti35Nb10Zr alloy had better mechanical strength and corrosion resistance due to Nb2O5 e ZrO2. However, the bulk metal of Ti6Al4V suffered less mechanical wear. Concluding, Ti35Nb10Zr alloy appear as promising candidate for dental implant-abutment sets manufacturing.
589

Osteogênese sobre titânio com nanotopografia

Schwartz Filho, Humberto Osvaldo [UNESP] 19 September 2011 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-19Bitstream added on 2014-11-10T11:57:36Z : No. of bitstreams: 1 000697140_20151015.pdf: 232164 bytes, checksum: 0bed7471a6786fe38e3164319d6deb3e (MD5) Bitstreams deleted on 2015-08-07T12:19:55Z: 000697140_20151015.pdf,. Added 1 bitstream(s) on 2015-08-07T12:20:58Z : No. of bitstreams: 1 000697140.pdf: 6167998 bytes, checksum: bf8732b598c57469944be2ab9eac1b0c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos deste estudo foram avaliar a influência da nanotopografia de superfícies de titânio no processo de osteogênese por meio de avaliação histológica do contato osso-implante, em ratos, sob efeito da inalação forçada da fumaça de cigarro; Avaliar a osteogênese e a expressão de citocinas em cultura de células primárias sobre discos de titânio com nanotopografia; E avaliar o efeito morfológico e molecular da incorporação da laminina-1 (LN-1) em superfícies com nanotopografia, em coelhos. Implantes e discos de titânio foram especialmente produzidos e submetidos a diferentes métodos para a obtenção de superfícies: usinada, micro e nanotopografia. As superfícies foram devidamente caracterizadas quanto a sua topografia, morfologia e química. Os resultados mostraram que: a nanotopografia é capaz de aumentar o contato osso-implante (BIC) mesmo na presença da inalação intermitente da fumaça de cigarro, e foi capaz de reduzir, porem não totalmente, seus efeitos deletérios e uma menor formação óssea; A nanotopografia de titânio pode ter papel importante no processo de mineralização da matriz extracelular e na modulação da expressão de citocinas; E que a incorporação de LN-1 a superfície de titânio com nanotopografia demonstrou favorecer uma maior expressão de importantes genes envolvidos na cascata da osseointegração. / The aims of this study were to evaluate the influence of nanotopography of titanium surfaces in the process of osteogenesis by means of histological assessment of bone-implant contact, in rats, under the effect of forced inhalation of cigarette smoke; To assess the osteogenesis process and the expression of cytokines in primary cell culture on titanium disks with nanotopography; And evaluate morphological and molecular the effect of incorporation of laminin-1 (LN-1) surfaces with nanotopography, in rabbits. Implants and titanium disks were specially produced and submitted to different methods for obtaining surfaces with turned, micro and nanotopography. The surfaces have been properly characterized as its topography, morphology and chemistry. The results showed that: nanotopography is able to increase bone-implant contact (BIC) even in the presence of intermittent inhalation of cigarette smoke, and was able to reduce, although not entirely, their harmful effects and a lower bone formation; Nanotopography may play a important role in mineralization process and in cytokine expression.; And the incorporation of LN-1 on titanium surface with nanotopography favor a higher expression of important genes involved in the cascade of osseointegration.
590

Comparação entre diferentes técnicas de moldagem utilizando transferentes específicos para implantes de hexágono interno: esquema all-on-4

Silva, Lívia Amato Conceição Bueno da [UNESP] 10 March 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-10Bitstream added on 2014-12-02T11:21:06Z : No. of bitstreams: 1 000796324.pdf: 4559037 bytes, checksum: 023da0ac027b41edfc3f3def0c558c80 (MD5) / O assentamento passivo é um dos pré-requisitos mais importantes na reabilitação oral sobre implantes com carga imediata e na manutenção da osseointegração. Devido à importância da obtenção de passividade no sucesso de reabilitações protéticas sobre implantes, da não observância de consenso sobre as técnicas de moldagens e da ausência de trabalhos que avaliem a moldagem em reabilitações baseadas no conceito “All-on-4”, o presente estudo teve por objetivo analisar “in vitro” a precisão de diferentes métodos de moldagem em reabilitações protéticas sobre implantes de hexágono interno instalados em um modelo anatômico metálico de maxila desdentada. Foram variáveis do presente estudo a técnica de moldagem (Aberta, Fechada e Index) e os métodos de união dos transferentes (transferentes cônicos sem união, transferentes quadrados Inteligentes unidos com bastões de resina Pattern pré-fabricados e transferentes quadrados Inteligentes unidos com bastões metálicos, cianoacrilato e resina Pattern). Após a obtenção dos moldes (ExpressTM XT 3M/ESPE), foram produzidos quarenta modelos (4 grupos; n=10) sob espatulação mecânica à vácuo com gesso tipo IV (Fuji-Rock EP). Uma estrutura metálica confeccionada sobre o modelo mestre com assentamento passivo foi parafusada nos modelos obtidos, no análogo A enquanto foram feitas medições nos análogos C e D e quando parafusada no análogo D as medições foram feitas nos análogos A e B, por um programa (Leica QWin) que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa Leica (100X). Houve diferença significativa nas comparações entre as técnicas de moldagens e o modelo mestre, exceto para o grupo Quadrado Inteligente / Metal + Pattern (G2) com fenda média de 65 μm, sendo estatisticamente semelhante ao modelo mestre (60 μm). O grupo Index (G4) apresentou as menores desadaptações (38 μm). / The passive fit is one of the most important prerequisites in oral rehabilitation on implants with immediate loading and maintenance of osseointegration. Due to the importance of obtaining passivity in the success of prosthetic rehabilitation on implants, the failure of consensus on the techniques of molding and the absence of studies that evaluate the molding rehabilitation based on the concept All-on-4, the present study aims to analyze in vitro the accuracy of different methods of forming prosthetic rehabilitation in internal hexagon implant anatomical model installed in a metal jaw toothless. Variables in this study are the molding technique (Open, Closed and Index), transfer methods (conical transfer - no union and Intelligent square transfer), as well as methods of union of Intelligent square transfer (united Pattern resin sticks to prefabricated and joined together with metal sticks with cyanoacrylate resin and Pattern). After obtaining the molds (ExpressTM 3M/ESPE XT), forty models will be produced (4 groups; n=10) under mechanical vacuum mixing with type IV gypsum (Fuji-Rock EP). A metal structure fabricated on the master model with passive fit was screwed in the models obtained, on A analogue while measurements were made on analogs C and D and when screwed into analog D measurements were made in analogues A and B, by a program (Leica QWin) that received the images from a video camera coupled to a Leica (100X) loupe. There were significant differences in the comparisons between the techniques of molding and the master model, except for the Smart Square / Metal + Pattern (G2) with gap 65 μm, which behaved statistically similar to the master model group (60 μm). The Index group (G4) presented the less desadaptations (38 μm).

Page generated in 0.0611 seconds