• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 833
  • 523
  • 82
  • 45
  • 31
  • 24
  • 21
  • 21
  • 20
  • 20
  • 19
  • 17
  • 13
  • 12
  • 11
  • Tagged with
  • 1885
  • 853
  • 745
  • 493
  • 257
  • 239
  • 196
  • 185
  • 175
  • 148
  • 141
  • 134
  • 133
  • 128
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
611

Efeitos da irradiação com laser de Er, Cr:YSGG na morfologia superficial e na temperatura do osso adjacente a implantes odontológicos / Effects of Er,Cr:YSGG laser irradiation on the adjacent bone temperature and surface morphology of dental implants

GOTTARDI, MARIELLA da S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:56Z (GMT). No. of bitstreams: 1 16948.pdf: 2577003 bytes, checksum: 13db4c3a7fca2217421f38b0cc65c24d (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP; Faculdade de Odontologia, Universidade de São Paulo, São Paulo
612

Desenvolvimento, caracterização e estudo pré-clínico de dispositivos implantáveis biocompatíveis baseados no polímero poli(?-caprolactona) / Development, characterization and preclinical evaluation of the implantable biocompatible prototypes based on poli(?-caprolactona)

SILVA, FABIANA M. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:59Z (GMT). No. of bitstreams: 1 16497.pdf: 92708 bytes, checksum: 7ccf16810b03dfc8aa4c309390f8b21a (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
613

Cultivo e irradiação de fibroblastos humanos em meio enriquecido com lisado de plaquetas para obtenção de camada de sustentação em cultura de células da epiderme / Cultivation and irradiation of human fibroblasts in a medium enriched with platelet lysate for obtaining feeder layer in epidermal cell culture

YOSHITO, DANIELE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:14Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:16Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
614

Análise comparativa da interface osso-implante, em tíbia de coelho, utilizando fresa cirúrgica e laser de Er, Cr:YSGG

ROSSI, MAURO C.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:56Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:33Z (GMT). No. of bitstreams: 1 12800.pdf: 1108123 bytes, checksum: 3ac84397d025fe220be131b72636ae78 (MD5) / Dissertação (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de São Paulo, São Paulo
615

Análise histológica, imunoistoquímica e morfométrica de biópsias de tecidos ósseo de pacientes hipertensos compensados / Histological, molecular and morphometric analysis of bone tissue biopsies in compensated hypertensive patients

Fabris, André Luis da Silva [UNESP] 28 July 2016 (has links)
Submitted by ANDRÉ LUÍS DA SILVA FABRIS null (andre.fabris@hotmail.com) on 2016-08-18T20:52:14Z No. of bitstreams: 1 Defesa_Andre_12.08.16.pdf: 6198533 bytes, checksum: 628414a513735df84a437ab8c7c82233 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-22T18:17:44Z (GMT) No. of bitstreams: 1 fabris_als_dr_araca_par.pdf: 253349 bytes, checksum: 0fdc6afd35eba2551f38a3b77ac48711 (MD5) / Made available in DSpace on 2016-08-22T18:17:44Z (GMT). No. of bitstreams: 1 fabris_als_dr_araca_par.pdf: 253349 bytes, checksum: 0fdc6afd35eba2551f38a3b77ac48711 (MD5) Previous issue date: 2016-07-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: O presente estudo objetivou avaliar as características morfométicas, histológicas e imunoistoquímicas do tecido ósseo coletado de pacientes portadores de hipertensão arterial sistêmica compensada pelo uso de medicamentos antagonistas do sistema renina-angiotensina-aldoesterona (SRAA). Materiais e Métodos: Trinta pacientes com indicação para reabilitação por meio de implantes instalados na região posterior de mandíbula foram divididos em dois grupos, seguindo os critérios de inclusão e exclusão previamente estabelecidos. O primeiro grupo não apresentava alterações sistêmicas (GSA) e não fazia uso de qualquer medicação e, o segundo grupo foi composto por pacientes hipertensos diagnosticados e medicados por antagonistas do SRAA (GAS). Durante o procedimento cirúrgico para instalação dos implantes osseointegráveis com superfície texturizada, foram coletados blocos ósseos por meio de biópsia com broca trefina de 3,0mm de diâmetro nos locais de instalação dos implantes. As biópsias coletadas foram separadas para avaliação por microtomografia computadorizada, sendo avaliados os seguintes parâmetros: volume ósseo (BV/TV), percentual de volume ósseo (BV/TV), espessura de trabéculas (Tb.Th), número de trabéculas (Tb.N), separação entre as trabéculas (Tb.S) e porosidade total (Po-tot). Também foi realizada a análise dos cortes histológicos corados por hematoxilina e eosina, bem como a avaliação imunoistoquímica de proteínas que caracterizam as células da linhagem osteoblástica: Runx2, Osteopontina e Osteocalcina. Resultados: Para todos os parâmetros analisados (BV, BV/TV, Tb.Th, Tb.N, Tb.S e Po-tot), houve similaridade na comparação entre os grupos GAS e GSA (p<0,05, teste t). As imunomarcações para osteopontina e osteocalcina mostraram-se semelhantes nos dois grupos. Vale destacar importante marcação observada no grupo GAS para o fator de transcrição Runt 2 (Runx2), em comparação a marcação da mesma proteína no grupo GSA. Além disso, a biologia do tecido ósseo do ponto de vista histológico foi semelhante nos dois grupos. Conclusões: Foi possível concluir que indivíduos hipertensos tratados com antagonistas do SRAA apresentam grande similaridade óssea microestrutural e também celular/protéica aos indivíduos normotensos. / Objectives: This study aimed to evaluate the morphometric characteristics, histological and immunohistochemical bone tissue collected from patients with hypertension offset by the use of drugs antagonists of the renin angiotensin system. Material and Methods: 30 patients referred for rehabilitation with implants placed in the posterior mandible were divided into two groups, following the criteria of inclusion and exclusion previously established. The first group showed no systemic changes (GSA) and did not use any medication and the second group was composed of diagnosed hypertensive patients treated by RAAS (GAS) antagonists. During the procedure for installation of dental implants with textured surface, they were collected bone blocks through biopsy trephine drill 3.0mm diameter implants in the installation sites. The collected biopsies were separated fo evaluatio by microtomography, being evaluated the following parameters: bone volume (BV / TV), trabecular thickness(Tb.Th), trabecular number (Tb.N), separation of the trabecular (Tb.S) and total porosity (Po-tot). Also the analysis of histological sections stained with hematoxylin and eosin staining was performed as well a the immunohistochemical evaluation of proteins that characterize the cells of osteoblast lineage: Runx2, osteopontin and osteocalcin. Results: For all parameters (BV, BV / TV, Tb.Th, Tb.N, Tb.S and E-tot) were similar in the comparison between GAS and GSA (p> 0.05, t test). The biology of bone tissue to analyze by immunohistochemistry presented similar results in both groups, with markings scores in ordinal qualitativ analysis for transcription factor related to Runt 2 (Runx2) GSA (light) and GAS (moderate), osteopontin (OP) GSA (mild to moderate) and GAS (moderate to intense), osteocalcin (OC) GSA (intense) and GAS (moderate). Furthermore, the biology of bone tissue was histologically similar in both groups. Conclusions: Therefore, it was concluded that hypertensive subjects treated with renin-angiotensin system antagonists have great bone microstructural similarity and also cell/protein to normotensive individuals.
616

Avaliação da estabilidade primária de implantes instalados em cavidades confeccionadas por meio do ultrassom cirúrgico e instrumentos rotatórios convencionais: Estudo in Vitro / Assessment of the primary stability of dental implants prepared cavities with piezosurgery and conventional rotatory instruments: In Vitro study

Silva, Leonardo de Freitas [UNESP] 17 October 2016 (has links)
Submitted by LEONARDO DE FREITAS SILVA null (leonardofreitas86@gmail.com) on 2016-10-20T13:26:49Z No. of bitstreams: 1 Dissertação de mestrado- reapresentação 1.pdf: 1472109 bytes, checksum: e157f95a9ba34bce0469c51f091af276 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-10-26T17:52:37Z (GMT) No. of bitstreams: 1 silva_lf_me_arafo.pdf: 1472109 bytes, checksum: e157f95a9ba34bce0469c51f091af276 (MD5) / Made available in DSpace on 2016-10-26T17:52:37Z (GMT). No. of bitstreams: 1 silva_lf_me_arafo.pdf: 1472109 bytes, checksum: e157f95a9ba34bce0469c51f091af276 (MD5) Previous issue date: 2016-10-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A estabilidade primária de implantes dentários corresponde a um fenômeno mecânico relativo à qualidade ou quantidade óssea, ao tipo de implante e a técnica de instalação. O objetivo deste trabalho foi avaliar o tempo de fresagem, aquecimento dos sítios fresados e a estabilidade dos implantes instalados em cavidades realizadas com ultrassom cirúrgico e instrumentos rotatórios. Foram realizadas 64 cavidades em 04 blocos de poliuretano simulando as densidades de ossos tipo I, II, III e IV. A temperatura da superfície do bloco nos leitos foi medida durante a fresagem. A estabilidade dos implantes foi mensurada por meio do torque de inserção, de remoção e frequência de ressonância. O implante cilíndrico TitaOss 3,75 x 11 mm foi instalado em todas as cavidades. Os resultados mostraram maior tempo e temperatura para o grupo em que foi usado o ultrassom. Quanto à estabilidade primária não houve diferença significante entre os grupos estudados. Pôde-se concluir que a estabilidade primária dos implantes não foi influenciada pelos métodos de fresagem utilizados e que o ultrassom cirúrgico necessitou de mais tempo e gerou mais calor do que o instrumento rotatório para o preparo das cavidades. / The primary stability of dental implants corresponds to a mechanical phenomenon related to bone quality or quantity, type of implant and installation technique. The objective of this study was to evaluate the time of drilling, heating drilled sites and stability of implants placed in cavities made with piezosurgery and rotary instruments. Polyurethane blocks were used simulating the densities of bone type I, II, III and IV. The surface temperature of the block was measured in the cavity during drilling, and recorded the highest temperature variation. The stability of the implants was measured with a torque insertion, torque of removal and resonance frequency. The cylindrical implant TitaOss 3.75 x 11 mm was used in all cavities. The results showed greater time and temperature for the group that was used piezosurgery. The primary stability was no significant difference between groups. It could be concluded that implant primary stability was not influenced by the used methods and piezosurgery took more time and generated more heat than the conventional rotatory instruments to prepare the cavities.
617

Análise da distribuição das tensões em próteses protocolo mandibulares com estruturas fresadas por CAD/CAM e confeccionadas pela técnica convencional: análise pela fotoelasticidade e extensometria / Analysis of stress distribution in full-arch fixed mandibular prosthesis with structures made with the CAD/CAM technology and with the conventional technique: evaluation through photoelastic and strain gauge analysis

Medeiros, Rodrigo Antonio de [UNESP] 12 December 2016 (has links)
Submitted by RODRIGO ANTÔNIO DE MEDEIROS null (rodrigomedeiros88@hotmail.com) on 2017-01-17T18:59:53Z No. of bitstreams: 1 Tese_Rodrigo Medeiros.docx: 4055404 bytes, checksum: 8420d48d6379115c0945c7b9f391bbc6 (MD5) / Rejected by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: Incluir o número do processo de financiamento nos agradecimentos da dissertação/tese. A versão final da dissertação/tese deve ser submetida no formato PDF (Portable Document Format). O arquivo PDF não deve estar protegido e a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos, se houver. Por favor, estas informações e realize uma nova submissão. Agradecemos a compreensão. on 2017-01-20T15:26:30Z (GMT) / Submitted by RODRIGO ANTÔNIO DE MEDEIROS null (rodrigomedeiros88@hotmail.com) on 2017-01-20T21:34:08Z No. of bitstreams: 1 Tese_Rodrigo Medeiros.pdf: 2572700 bytes, checksum: 14ceeb89edad876baa95811c229c59dd (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-23T19:00:09Z (GMT) No. of bitstreams: 1 medeiros_ra_dr_araca.pdf: 2572700 bytes, checksum: 14ceeb89edad876baa95811c229c59dd (MD5) / Made available in DSpace on 2017-01-23T19:00:09Z (GMT). No. of bitstreams: 1 medeiros_ra_dr_araca.pdf: 2572700 bytes, checksum: 14ceeb89edad876baa95811c229c59dd (MD5) Previous issue date: 2016-12-12 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo desse estudo foi avaliar a distribuição de tensão, por meio dos métodos fotoelástico e extensometria, em próteses protocolo mandibulares (tipo Branemärk) com infraestruturas confeccionadas com diferentes materiais e técnicas, sob força de compressão. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula que recebeu cinco implantes 4x11 mm hexágono externo entre os forames mentonianos. Os grupos foram divididos em: Grupo I - infraestrutura fundida em níquel-cromo com revestimento oclusal em resina acrílica (n=7); Grupo II - infraestrutura fundida em níquel-cromo com revestimento oclusal em cerâmica (n=7); Grupo III - infraestrutura fresada em Zircônia estabilizada por óxido de ítrio com revestimento em cerâmica (n=7). Inicialmente, foi realizado o teste da fotoelasticidade e, posteriormente, a extensometria. Pela metodologia da fotoelasticidade, com auxílio de uma máquina de ensaio universal (EMIC) foram aplicadas cargas axiais de 70 N na região do implante mais anterior, entre os incisivos, e no centro do primeiro molar de cada lado. Por meio de imagens fotográficas e com o auxílio do programa Adobe Photoshop CS6, as imagens foram analisadas de acordo com o número de franjas de alta intensidade nos grupos testados. Para a metodologia da extensometria, as cargas foram aplicadas da mesma maneira da metodologia da fotoelasticidade e a medição das tensões foi realizada em duas regiões distintas. Para a primeira região, dois extensômetros elétricos de resistência foram posicionados horizontalmente na região mesial e distal dos cinco implantes, diretamente sobre a crista marginal do modelo fotoelástico. Para a segunda região, a resina fotoelástica foi removida da superfície vestibular e lingual de cada implante, sendo mantida1 mm de resina intacta, onde os extensômetros foram fixados verticalmente. Foram realizados os mesmos testes de compressão descritos anteriormente. Os valores de tensão registrados foram agrupados em tabelas e submetidas à análise de variância (ANOVA) dois fatores e ao teste de Tukey com significância de 5%. Os resultados das duas metodologias demonstraram menores valores de tensão para o Grupo I, quando comparado aos demais grupos. É possível concluir que as próteses protocolo com infraestrutura fundida em metal e revestimento oclusal acrílico demonstraram melhores resultados biomecânicos. / This study aimed to evaluate the stress distribution in full-arch fixed mandibular prosthesis (Branemärk type) with infrastructure made of different materials and techniques, and under compressive force, through photoelastic and strain gauge analysis. A photoelastic cast of an edentulous jaw was fabricated and received five external hexagon implants (4x11mm) between the mental foramen. The groups were divided into: Group I - Nickel-Chrome fused infrastructure with acrylic resin occlusal coating; Group II - Nickel-Chrome fused infrastructure with ceramic occlusal coating; Group III - Yttria-stabilized zirconia fused infrastructure with ceramic coating. First, the photoelastic analysis was performed and later the strain gauge analysis. A force of 70 N was applied by using a testing machine (EMIC) in the region of the most anterior implant, between incisors, and in the center of the first molar on each side. The images were analyzed by a blinded evaluator through images and by using Adobe Photoshop CS6, according to the number of high intensity fringes in each group. Regarding the strain gauge analysis, the stress measure was performed in two distinct regions. For the first region, two resistance strain gauges were placed horizontally in the mesial and distal regions of the five implants, directly on the marginal ridge of the photoelastic cast. For the second region, the photoelastic resin was removed on the buccal and lingual surfaces of each implant, leaving 1 mm of intact resin, where the strain gauges were placed vertically. The same compression tests described above were carried out. Data were submitted to two-way ANOVA and to the Tukey post-hoc test with 5% level of significance. The results of both methods showed lower stress values for Group I, when compared to other groups. It can be concluded that when rigid materials are used for infrastructure fabrication, the esthetic coating influences the load generated on the marginal bone around the implant. The ceramic coating showed less satisfactory results. / FAPESP: 2014/14088-0 / FAPESP: 2014/11605-3
618

Efeitos da radioterapia no processo de neoformação óssea na interface osso/implante e na expressão de citocinas IL-6 e TGF-ß: estudo in vivo / Effects of radiotherapy on the process of bone neoformation at the bone/implant interface and on the expression of IL-6 and TGFf-ß cytokines: in vivo study

Costa, Bruno César Almeida 02 May 2018 (has links)
Submitted by BRUNO CÉSAR ALMEIDA COSTA (brunnocesaracosta@hotmail.com) on 2018-05-14T19:21:25Z No. of bitstreams: 1 Dissertação _ Bruno Costa _ Completa 14_05.pdf: 1611275 bytes, checksum: 5bb1aa80f51943c2d30ac036450829f3 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-05-14T19:42:43Z (GMT) No. of bitstreams: 1 costa_bca_me_sjc.pdf: 1611275 bytes, checksum: 5bb1aa80f51943c2d30ac036450829f3 (MD5) / Made available in DSpace on 2018-05-14T19:42:44Z (GMT). No. of bitstreams: 1 costa_bca_me_sjc.pdf: 1611275 bytes, checksum: 5bb1aa80f51943c2d30ac036450829f3 (MD5) Previous issue date: 2018-05-02 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / No tecido ósseo, as injúrias decorrentes da radioterapia variam desde osteopenia até osteoradionecrose e devido a estas alterações, pacientes irradiados portadores de implantes vêm demonstrando maior taxa de insucesso. O objetivo neste estudo foi avaliar os efeitos da radioterapia, simulando uma dose total de um tratamento radioterápico convencional para pacientes oncológicos, na neoformação óssea ao redor de implantes instalados em fêmures de ratos, assim como na expressão de citocinas IL-6 e TGF-ß. Foram utilizados neste estudo 36 ratos que receberam implantes rosqueados de titânio grau V nos fêmures esquerdos. Os animais foram divididos em 3 grupos: a) Grupo controle (C): cirurgia de colocação dos implantes (tecido sadio sem irradiação); b) Grupo irradiação (I): irradiação e após 4 semanas cirurgia de colocação dos implantes c) Grupo irradiação imediata (IP): cirurgia de colocação dos implantes e depois de 24 horas irradiação. A irradiação foi realizada em duas etapas com doses de 15 Gy, totalizando ao final da segunda dose 30 Gy. Os animais foram eutanasiados nos períodos de 3 dias, 2 e 7 semanas após o tratamento. No momento da eutanásia, 0,5 ml de sangue foi coletado e os níveis séricos de IL-6 e TGF-β foram mensurados pelo método imunoenzimático (ELISA). Em cada período 04 animais foram submetidos à microtomografia computadorizada (µCT), visando avaliar a neoformação óssea na interface osso-implante. Os valores obtidos foram submetidos ao teste ANOVA um fator para análise estatística e quando necessário foi aplicado o teste de comparação múltipla de Tukey (p<0,05). Nos resultados obtidos por meio da análise de microtomografia em geral não foi observada diferença estatística entre os grupos (p>0,05). Contudo, no parâmetro volume ósseo observou-se no período de 2 semanas, diferença estatística (p<0,05) entre os grupos C e IP e o parâmetro separação de trabéculas mostrou no período de 2 e 7 semanas, diferença estatística (p<0,05) entre os grupos C e IP e Na avaliação de IL-6 o grupo C exibiu o maior valor e foi observada diferença estatisticamente significante (p<0,05) entre ele e os demais grupos em todos os períodos. Na avaliação de TGF-β foi observada diferença estatisticamente significante (p<0,05) entre o grupo I em comparação com os outros grupos nos períodos de 3 dias e 2 semanas, sendo o grupo I aquele que apresentou maior expressão. Concluiu-se que o osso irradiado recupera-se da irradiação com o decorrer do tempo, porém quando a irradiação ocorre imediata a cirurgia do implante o tecido ósseo exibe alterações mais significativas. / In bone tissue, the injuries resulting from radiotherapy vary from osteopenia to osteoradionecrosis and due to these alterations, irradiated patients with implants have been showing a higher rate of failure. The objective of this study was to evaluate the effects of radiotherapy, simulating a total dose of a conventional radiotherapy treatment for cancer patients, in the new bone formation around implants in rat femurs, as well as in the expression of IL-6 and TGF-β cytokines . Thirty-six rats receiving grade V titanium implants in the left femora were used in this study. The animals were divided into 3 groups: a) Control group (C): implant placement surgery (healthy tissue without irradiation); b) Group irradiation (I): irradiation and after 4 weeks implant placement surgery c) Immediate irradiation (IP) group: implant placement surgery and after 24 hours irradiation. Irradiation was performed in two steps with doses of 15 Gy, totaling at the end of the second dose 30 Gy. The animals were euthanized at 3 days, 2 and 7 weeks after treatment. At the time of euthanasia, 0.5 ml of blood was collected and serum levels of IL-6 and TGF-β were measured by the enzyme-linked immunosorbent assay (ELISA). In each period, 04 animals were submitted to computerized microtomography (μCT), aiming to evaluate the bone neoformation at the bone-implant interface. The obtained values were submitted to ANOVA a factor for statistical analysis and when necessary the Tukey multiple comparison test (p <0.05) was applied. In the results obtained through the microtomography analysis in general no statistical difference was observed between the groups (p> 0.05). However, the parameter separation of trabeculae showed, in the period of 2 and 7 weeks, statistical difference (p <0.05) between groups C and PI and in the bone volume parameter showed in the period of 2 weeks, statistical difference (p <0, 05) between groups C and IP. In the evaluation of IL-6, group C showed the highest value and a statistically significant difference (p <0.05) was observed between him and the other groups in all periods. In the evaluation of TGF-β, a statistically significant difference (p <0.05) was observed between group I in comparison with the other groups in the periods of 3 days and 2 weeks, with group I being the one with the highest expression. It was concluded that irradiated bone recovers from irradiation over time, but when irradiation occurs near implant surgery, the bone tissue exhibits more significant changes. / 2015/24986-8
619

Estudo comparativo entre as esferas de silicone gelatinosas e rígidas em cavidade eviscerada de coelho /

Kanamura, Mayumi Shirota. January 2011 (has links)
Orientador: Silvana Artioli Schellini / Banca: Suzana Matayoshi / Banca: David Araf / Resumo: Apesar da existência de inúmeros tipos de implantes para reposição de volume em cavidades anoftálmicas, até o momento, nenhum deles pode ser considerado ideal, o que faz com que seja necessário continuar buscando novas soluções. Avaliar a biocompatibilidade de esferas de silicone gelatinosas e rígidas, quando colocadas em cavidades evisceradas de coelhos, comparando-as. Estudo prospectivo e experimental, no qual foram utilizados 30 coelhos albinos, espécie Orictolagus cuniculus, submetidos à cirurgia de evisceração do olho direito, sendo feita a colocação de esferas de silicone gelatinosas ou rígidas na cavidade escleral. Os animais foram sacrificados sete, 30 e 90 dias após a colocação das esferas. Os parâmetros avaliados foram: avaliação clínica diária, ultrassonografia da cavidade eviscerada 15 dias após o procedimento, análise histológica do conteúdo orbitário sete, 30 e 90 dias após a cirurgia, com análise morfométrica da pseudocápsula que se formou ao redor das esferas. Os resultados obtidos foram submetidos à avaliação estatística para comparação dos resultados entre e dentro dos grupos experimentais. Durante o seguimento, ocorreram três extrusões de esferas, duas das quais pertencentes ao grupo das esferas rígidas e uma, do grupo das esferas gelatinosas. O exame ultrassonográfico mostrou ausência de coleções ou processo inflamatório ao redor das esferas e boa integração das mesmas com os tecidos orbitários. Ao exame histológico observou-se semelhança de resposta tecidual com ambas as esferas. O exame morfométrico apontou para superioridade das esferas gelatinosas no tocante a espessura da pseudocápsula, que foi menos espessa, principalmente na avaliação feita no setor posterior da cavidade escleral. Todos os parâmetros estudados mostraram que as esferas de silicone... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Despite the existence of many types of implants for volume replacement in anophthalmic sockets, so far, none can be considered ideal implant, which makes it necessary to continue searching for new solutions. To evaluate the biocompatibility of soft and rigid silicone spheres placed in scleral cavities of eviscerated rabbits, comparing them. Prospctive and experimental study using 30 rabbits, specie Orictolagus cuniculus, underwent evisceration surgery of the right eye and replacement of orbital volume with spheres composed by gelatinous (soft) or rigid silicone. The animals were sacrificed seven, 30 and 90 days after surgery. The studies parameters were: daily clinical assessment, ultrasound of the orbit 15 days after the procedure, histological analysis of the orbital contents seven, 30 and 90 days after surgery and morphometric evaluation in the pseudocapsule in all the animals. Statistical analysis for comparison between and within groups was done. During follow-up occurred three spheres extrusions, two of which belonging to the group of rigid spheres and one from gelatinous sphere group. Ultrasound examination showed no inflammation or collections around spheres and good integration with the orbital tissues. The histological evaluation proved both materials had similar response and the morphometric evaluation showed thinner pseudocapsule formation around the gelatinous sphere, mainly in the posterior scleral region. All the parameters evaluated showed both spheres had good tecidual integration to the orbital tissue in rabbit eviscerated eyes. Therefore, gelatinous silicone sphere induced thinner psedudocapsule formation. The authors agree the gelatinous silicone spheres might be helpful to be used... (Complete abstract click electronic access below) / Mestre
620

Avaliação da prevalência das doenças peri-implantares e do sucesso e sobrevivência de implantes osseointegrados com 8 a 10 anos de função /

Marcantonio, Claudio. January 2014 (has links)
Orientador: Daniela Leal Zandim Barcelos / Co-orientador: / Banca: José Eduardo Cezar Sampaio / Banca: Francisco de Assis Molo Junior / Banca: Rafael Silveira Faeda / Banca: Waldyr Antonio Jorge / Resumo: O propósito deste estudo retrospectivo foi verificar as taxas de sucesso e sobrevivência de implantes osseointegrados no longo prazo, assim como determinar a prevalência de doenças peri-implantares e identificar possíveis fatores de risco associados à ocorrência da peri-implantite. A amostra foi constituída de 50 pacientes parcialmente desdentados que realizaram reabilitações sobre implantes osseointegrados no período de 2003 a 2005. As avaliações incluíram a coleta de informações demográficas, sistêmicas e comportamentais, além de exames clínicos e radiográficos para avaliação da condição periodontal e peri-implantar. Uma análise multivariada foi adotada para identificar possíveis preditores de risco para a periimplantite. Um total de 211 implantes foram instalados nestes pacientes. Cinco implantes foram perdidos e 9 implantes encontravam-se submersos, ou seja, sem função. Assim, 197 implantes em 48 pacientes foram avaliados clinicamente. A prevalência de mucosite foi de 77,1% a nível de paciente e 52,3% a nível de implante. A peri-implantite foi diagnosticada em 25 implantes em 14 pacientes. As taxas de sucesso e de sobrevivência encontradas foram de 82% e de 97,6%, respectivamente. A presença de osteoporose (OR = 2,87) e a presença de sangramento à sondagem (SS) de boca toda ≥ 30% dos sítios (OR = 8,03) foram variáveis relacionadas ao indivíduo significativamente associadas com maior ocorrência de periimplantite. A presença de placa visível (OR = 4,45) e a presença de sítios com profundidade de sondagem (PS) ≥ 4 mm (OR = 4,47) foram variáveis relacionadas ao implante significativamente associadas com maior ocorrência de peri-implantite. Apesar da alta taxa de sobrevivência no longo prazo, foi observada uma alta prevalência de mucosite e a peri-implantite foi diagnosticada em 12,7% dos implantes e 29,2% dos pacientes avaliados...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract:The aim of the present study was to verify the long-term success and survival rates of osseointegrated dental implants, as well to determine the prevalence of peri-implant disease, and to identify potential risk factors associated to the occurrence of peri-implantitis. The sample was comprised of 50 patients who had their implant-supported rehabilitation concluded between the years of 2003 and 2005. Evaluations included the gathering of demographic, systemic and behavioral information, as well as radiographic and clinical records for the assessment of periodontal and peri-implant conditions. Multivariate analysis was employed to identify potential risk factors related to the occurrence of peri-implantitis. A total of 211 implants were installed, out of which 5 were lost and 9 were submerged, that is, nonfunctioning. Thus, 197 implants in 48 patients were clinically evaluated. The presence of osteoporosis (OR = 2,87) and the presence of full-mouth BOP scores ≥ 30% of sites (OR = 8,03) were variables significantly associated with a higher occurrence of peri-implantitis, among the subjects. At the implant level, the presence of visible plaque (OR = 4.45) and the presence of sites with probing depth (PD) ≥ 4 mm (OR = 4.47) were variables significantly associated with a higher occurrence of peri-implantitis. Mucositis prevalence was 77.1% and 52.3%, at subject and implant level, respectively. Periimplantitis was diagnosed in 25 implants (12.7%) and 14 patients (29.2%). Success and survival rates were 82% and 97.6%, respectively. Our results suggest that subjects with osteoporosis and with full-mouth BOP scores ≥ 30% of the sites, as well as implants with visible plaque and sites with PD ≥ 4 mm, are more susceptible to peri-implantitis. / Doutor

Page generated in 0.0447 seconds