• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 833
  • 523
  • 82
  • 45
  • 31
  • 24
  • 21
  • 21
  • 20
  • 20
  • 19
  • 17
  • 13
  • 12
  • 11
  • Tagged with
  • 1885
  • 853
  • 745
  • 493
  • 257
  • 239
  • 196
  • 185
  • 175
  • 148
  • 141
  • 134
  • 133
  • 128
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
621

Carbono tipo diamante em componentes de implantes dentários: avaliação das propriedades antimicrobianas e de adesão de Escherichia coli /

Maquera Huacho, Patricia Milagros. January 2014 (has links)
Orientador: Denise Madalena Palomari Spolidorio / Banca: Luis Geraldo Vaz / Banca: Rafael Silveira Faeda / Resumo: O estudo de filmes de Carbono tipo Diamante é objeto de pesquisas devido às suas diferentes propriedades incluindo propriedades antibacterianas. No tratamento reabilitador com implantes, podem ocorrer complicações, proporcionando a infiltração de microrganismos orais para a interface Implante-Componente protético. O objetivo deste estudo foi avaliar propriedades de molhabilidade e energia livre de superfície a partir dos valores do ângulo de contato; propriedades antimicrobiana, de bioadesão e citotoxicidade de discos de titânio recobertos com DLC. Escherichia coli foi mantida em meio BHI a 37ºC por 3 h e 24 h para teste antimicrobiano. Para adesão, os discos foram mantidos em cultura de E. coli por 90 minutos a 37ºC e 20 minutos em ultrassom. A capacidade de prevenção na migração de bactérias para o interior da interface Implante-Componente protético foi realizado em implantes Hexágono Externo, conectados com torque de 32N e deixados em contato com E. coli por 24h, e Reação em Cadeia da Polimerase semi-quantitativo foi realizado para confirmação da esterilidade da técnica. Foram quantificados em UFC/mL em BHI Ágar para o teste antimicrobiano, adesão e infiltração bacteriana. Para citotoxicidade foi utilizado queratinócitos humanos (HaCat) cultivados em meio DMEM mantidos em atmosfera com 5% de CO2 a 37°C e avaliados pelo teste colorimétrico MTT. Os resultados de molhabilidade, teste antimicrobiano, teste de adesão e Infiltração bacteriana não apresentaram diferença estatisticamente significante entre os grupos. As superfícies de titânio e recobertas com DLC apresentaram uma leve diminuição na viabilidade celular com diferença estatisticamente significante ao grupo controle. O DLC apresenta-se como material biocompatível com leve grau de citotoxicidade que não modifica as propriedades de superfície, não apresenta propriedades antimicrobianas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The study of DLC films is the subject of research due to their different properties including antibacterial properties. Rehabilitator in implant treatment, complications may occur, providing the infiltration of oral microorganisms for implant- abutmente interface. The aim of this study was to evaluate properties and wetting surface free energy from the values of the contact angle; antimicrobial properties bioadhesion and cytotoxicity of titanium discs coated with DLC. Escherichia coli was maintained on BHI at 37 ° C for 3 h and 24 h for antimicrobial test. For adhesion test, the discs were maintained in culture of E. coli for 90 minutes at 37 ° C and 20 minutes inside ultrasound. The ability to prevent the migration of bacteria into the implant - abutment interface was performed in dental implants External Hexagon connected with a torque of 32N and left in contact with E. coli for 24 h, and Polymerase Chain Reaction semi -quantitative was performed to confirm the sterility of the technique. Were quantified in CFU / ml in BHI agar for antimicrobial test, bacterial adhesion and infiltration. Cytotoxicity was performed using human keratinocytes ( HaCaT ) cultured in DMEM maintained in an atmosphere of 5% CO2 at 37 ° C and evaluated by the MTT colorimetric assay. The results of wettability, antimicrobial test, adhesion test and bacterial infiltration showed no statistically significant difference between the test groups. The surfaces of titanium and coated with DLC showed a slight decrease in cell viability with a statistically significant difference to the control group. The DLC is presented as biocompatible material with mild cytotoxicity without changing the surface properties, has no antimicrobial properties, does not interfere with bacterial adherence for E. coli and do not inhibit bacterial infiltration into the implant-abutment interface. / Mestre
622

Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares /

Carvalho, Helen Ramon Esper de. January 2015 (has links)
Orientador: Osvaldo Magro Filho / Banca: Francisley Ávila de Souza / Banca: Celso Koogi Sonoda / Banca: Paulo Domingos Ribeiro Junior / Banca: Camila Tirapelli / Resumo: Introdução: A utilização de biomateriais em reconstruções para implantodontia tem sido amplamente discutida nos últimos anos. Proposição: O objetivo deste trabalho foi analisar o comportamento biológico do vidro bioativo (Biogran®) e do osso bovino (Endobon®) durante o processo de osseointegração associados a implantes com defeitos periimplantares em tíbias de rato. Material e método: Foram instalados 75 implantes na tíbia esquerda de 75 ratos Wistar machos. Os implantes foram divididos em três grupos experimentais. No Grupo 1 (Controle) foi provocado um defeito periimplantar monocortical circular e os implantes foram inseridos e deixados apenas com coágulo. No Grupo 2 os implantes foram inseridos com o mesmo defeito ósseo e o espaço preenchido com Biogran® e no Grupo 3 o espaço entre osso e implante foi preenchido com Endobon®. Os animais foram submetidos à eutanásia aos 14 e 42 dias e realizaram-se as análises histológica, histométrica (porcentagem de extensão linear de contato osso-implante - BIC e área óssea - BA), imunoistoquímica (expressão das proteínas osteocalcina - OC e osteopontina - OPN) e biomecânica (torque reverso). Resultados: Histologicamente todos os implantes encontraram-se osseointegrados. Não foram observadas diferenças estatisticamente significantes nos valores de torque reverso (p> 0,05) aos 42 dias. Para BIC, aos 14 dias foi de 8,29; 15,04; e 16,20%, para os grupos 1, 2 e 3, respectivamente. Aos 42 dias, os valores médios de BIC foram 30,84; 33,13; e 13,93% para os mesmos grupos, demonstrando que não houveram diferenças estatísticas entre grupos, porém com respostas diferentes entre períodos. Para a quantificação de formação óssea por área (BA), a resposta entre grupos difere. A resposta da BA média do Grupo 1 (18,75%) não difere da resposta média do Grupo 3 (21,62%). Porém, difere... / Abstract: Introduction: The use of biomaterials in reconstructions for dental implants has been widely discussed in recent years. Proposition: The aim of this work was to analize the biological behavior of the bioactive glass (Biogran®) and bovine bone (Endobon®) during the osseointegration process associated with implants with peri-implant defects in rat tibia. Material and Methods: 75 implants were installed in the left tibia of 75 male Wistar rats. The implants were divided into three experimental groups. In Group 1 (Control) was caused monocortical circular peri-implant defect and the implants were inserted and left only with clot. In Group 2 implants were inserted with the same bone defect and the space filled with Biogran® and in Group 3 the space between bone and implant was filled with Endobon®. The animals were euthanized at 14 and 42 days and there were the histological analysis, histometric (percentage of linear extension bone-implant contact - BIC and bone area - BA), immunohistochemistry (expression of the proteins osteocalcin - OC and osteopontin - OPN) and biomechanics (reverse torque). Results: Histologically all implants were osseointegrated. No statistically significant differences were observed in the values of reverse torque (p> 0.05) at 42 days. For BIC, at 14 days was 8.29; 15.04; and 16.20% for the groups 1, 2 and 3, respectively. After 42 days, the BIC values were 30.84; 33.13; and 13.93% for the same groups, demonstrating that there were no statistical differences between groups, but with different responses between periods. For the quantification of bone formation per area (BA), the response differs between groups. The average BA response in Group 1 (18.75%) did not differ from the average Group 3 response (21.62%). However, different from Group 2 (34.73%). The immunohistochemical results were analyzed by Qualitative... / Doutor
623

Estudo das tensões em próteses sobre implantes esplintadas : análise pelo método da fotoelasticidade /

Villa, Luiz Marcelo Ribeiro. January 2013 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Marcelo Coelho Goiato / Banca: Stefan Fiuza de Carvalho Dekon / Banca: Regina Tamaki / Banca: Sandra Lúcia Dantas de Moraes / Resumo: Propósito: O objetivo deste estudo foi avaliar a influência da esplintagem e de diferentes comprimentos de implantes na distribuição de tensões em próteses implantossuportadas, sob carregamento axial e oblíquo, por meio do método da fotoelasticidade. Materiais e métodos: Um total de 05 modelos em resina fotoelástica foi confeccionado com diferentes situações propostas, realizaram-se 400 aplicações de carga para análise. As tensões foram consideradas de forma quantitativa e qualitativa utilizando um método randomizado e simples cego. A reprodutibilidade do estudo foi avaliada usando o coeficiente de correlação intra-examinador (CCI), erro sistemático e erro casual. A análise de variância a três critérios e pós-teste de Tukey foram utilizados e, valor de p>0.05 foi adotado para analisar as principais diferenças. Resultados: As mensurações mostraram elevado coeficiente de concordância intraexaminador (CCI>0.97). A esplintagem de próteses implantossuportadas agiu favoravelmente na distribuição de tensões e na transmissão de tensões para o implante adjacente (p<0.001), quando comparado a próteses unitárias. O carregamento oblíquo foi mais prejudicial e, pontecializou a formação de tensões em implantes adjacentes (p<0.001). O aumento do comprimento foi um fator significante na avaliação dos modelos B e C (p=0.004), o modelo B apresentou maior concentração de franjas quando comparado com D e E (p<0.001). Conclusão: As próteses implantossuportadas esplintadas comportaram-se melhor biomecanicamente quando comparadas as próteses unitárias. O aumento do comprimento teve relevância na redução de tensões. O carregamento oblíquo foi mais prejudicial para a distribuição de tensões quando comparado com o carregamento axial. / Abstract: Purpose: The purpose of this study was to evaluate the influence of different lengths and splinting of implants on stress distribution in implant-supported prostheses under axial and oblique loading by means of the method of photoelasticity. Materials and methods: 05 models in photoelastic resin was prepared with different proposed situations, there were 400 applications for load analysis. Tensions were considered quantitatively and qualitatively using a randomized, single blind method. The reproducibility of the study was assessed using the intra correlation coefficient, systematic error and random error. The analysis of variance to three criteria and post - Tukey tests were used, and p values > 0.05 was adopted to analyze the main differences. Results: The measurements showed a high intra-concordance coefficient (ICC> 0.97). The prosthetic implant splinting acted favorably in the distribution of stresses and strains in the transmission next to the implant (p<0.001) when compared to the unitary prosthesis. The oblique loading was more damaging and potentialized the formation of stresses in adjacent implants (p<0.001). The increase in length was a significant factor for the evaluation of the models B and C (p = 0.004), the model B had a higher concentration of fringes as compared with D and E (p<0.001). Conclusion: The prosthetic implant splinted behaved better biomechanically compared prosthetics unit. The increased length was important in reducing stress. The oblique loading was more detrimental to the stress distribution compared to axial loading. / Doutor
624

Reconstrução imediata de diferentes defeitos peri-implantares em implantes pós-exodônticos : análise histomorfométrica em cães /

Pereira, Flávia Priscila. January 2013 (has links)
Orientador: Eduardo Hochuli Vieira / Co-orientador: Daniele Botticelli / Banca: Idelmo Rangel Garcia Junior / Banca: Wilson Roberto Poi / Banca: Michel Reis Messora / Banca: Cassio Edvard Sverzut / Resumo: Objetivo: A proposta deste estudo foi avaliar a regeneração óssea de defeitos criados cirurgicamente e naturais circunferenciais (gap) de implantes pósexodônticos. Materiais e método: Para este estudo foram utilizados 8 cães da raça labrador, nos quais foram instalados implantes imediatos (pós-exodônticos) nos alvéolos dos dentes P2 (2o pré-molar) e M1 (1o molar) inferiores bilaterais. Nos implantes da região dos 2º pré-molares bilaterais foram criados cirurgicamente defeitos peri-implantares vestibulares que foram preenchidos de um lado por osso autógeno - OA e do outro por osso bovino inorgânico Bio-Oss ®- OB. Nos alvéolos correspondentes aos primeiros molares (M1) os implantes foram instalados e os gaps (defeitos naturais) existente entre a tábua óssea vestibular e o implante, foram preenchidos por Bone Ceramic ® - (grupo BC) ou somente coágulo (grupo COA). Todos os sítios cirúrgicos foram posteriormente recobertos por membrana de colágeno reabsorvível (Biogide ®) e mantidos com cicatrizador. Após 4 meses de pós-operatório, os animais foram eutanasiados e os blocos ósseos processados laboratorialmente para análise histomorfométrica. Resultados: Os resultados obtidos nos implantes instalados na região do P2 mostraram que os valores do IS-C foram ligeiramente maior (2.3±0.8mm) no grupo OA, comparado ao grupo OB (1.7± 0.7 mm), enquanto o IS-B dos grupos OA e OB foram respectivamente de 2.7±0.7mm e 2.2±1.0 mm no lado vestibular e de 1.6±0.8mm e 0.8±0.5mm no lado lingual. As médias dos valores de PM-C, PM-B e PM-IS no grupo OA e OB foram respectivamente de 4.3±0.9mm, 4.7±0.9mm, 2.0±1.6mm e 4.3±0.6mm... / Abstract: Objective: The purpose of these studies were to evaluate bone regeneration at natural or surgically-created buccal defects at implants placed immediately into extraction sockets (IPIES). Material and methods: Eight Labrador dogswere used and implants were placed immediately into the extraction sockets of P2 (second premolar ) and M1 (first molar), bilaterally. At P2, the buccal wall of the extraction sockets was removed bilaterally to create a standardized defect, 4 mm wide coronally, 2 mm wide apically, and 6 mm height. At P2 sites, Bio-Oss at the test (OB) or autogenous bone at the control (OA) sites were used to fill the defects. At M1 sites, Bone Ceramic ® at the test (BC) or the clot alone (COA) were used to fill the defects. All surgical sites were subsequently covered by a resorbable collagen membraneand a non-submerged healing was allowed . After 4 months the animals were euthanized, bone blocks harvested and processed for histomorphometric analysis . Results: at P2 sites, IS- C values were slightly higher (2.3±0.8mm) in the OA compared to the OB (1.7±0.7 mm). IS- B were 2.7 ± 0.7mm and 2.2 ± 1.0mm on the buccal side and 1.6 ± 0.8mm and 0.8 ± 0.5mm on the lingual side at OA and OB groups, respectively. The average values of PM- C , B - PM and PM -IS in OA and OB groups were 4.3 ± 0.9mm , 4.7 ± 0.9mm , 2.0 ± 1.6mm and 4.3 ± 0.6mm , 4.8 ± 0.6mm , 2.5 ± 0.8mm, respectively. A statistically significant difference was only observed in the thickness of the buccal bony crest at 2-5 mm apically to IS (the implant neck) when the biomaterial (S -OCbt )... / Doutor
625

Avaliação da estabilidade primária de implantes instalados em cavidades confeccionadas por meio do ultrassom cirúrgico e instrumentos rotatórios convencionais : estudo in vitro /

Silva, Leonardo de Freitas. January 2016 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Coorientador: Daniela Ponzoni / Banca: Francisley Ávila Souza / Banca: Abrahão Cavalcante Gomes de Souza Carvalho / Resumo: A estabilidade primária de implantes dentários corresponde a um fenômeno mecânico relativo à qualidade ou quantidade óssea, ao tipo de implante e a técnica de instalação. O objetivo deste trabalho foi avaliar o tempo de fresagem, aquecimento dos sítios fresados e a estabilidade dos implantes instalados em cavidades realizadas com ultrassom cirúrgico e instrumentos rotatórios. Foram realizadas 64 cavidades em 04 blocos de poliuretano simulando as densidades de ossos tipo I, II, III e IV. A temperatura da superfície do bloco nos leitos foi medida durante a fresagem. A estabilidade dos implantes foi mensurada por meio do torque de inserção, de remoção e frequência de ressonância. O implante cilíndrico TitaOss 3,75 x 11 mm foi instalado em todas as cavidades. Os resultados mostraram maior tempo e temperatura para o grupo em que foi usado o ultrassom. Quanto à estabilidade primária não houve diferença significante entre os grupos estudados. Pôde-se concluir que a estabilidade primária dos implantes não foi influenciada pelos métodos de fresagem utilizados e que o ultrassom cirúrgico necessitou de mais tempo e gerou mais calor do que o instrumento rotatório para o preparo das cavidades. / The primary stability of dental implants corresponds to a mechanical phenomenon related to bone quality or quantity, type of implant and installation technique. The objective of this stud y was to evaluate the time of drilling, heating drilled sites and stability of implants placed in cavities made with piezosurgery and rotary instruments. Polyurethane blocks were used simulating the densities of bone type I, II, III and IV. The surface tem perature of the block was measured in the cavity during drilling, and recorded the highest temperature variation. The stability of the implants was measured with a torque insertion, torque of removal and resonance frequency. The cylindrical implant TitaOss 3.75 x 11 mm was used in all cavities. The results showed greater time and temperature for the group that was used piezosurgery. The primary stability was no significant difference between groups. It could be concluded that implant primary stability was n ot influenced by the used methods and piezosurgery took more time and generated more heat than the conventional rotatory instruments to prepare the cavities. / Mestre
626

Implante de "proplast" em alveolo dental após exodontia por alveolectomia total : estudo histológico em cães /

Santos Júnior, Paulo Villela. January 1980 (has links)
Orientador: Ronaldo Maia Melhado / Resumo: Não disponível / Abstract : Not Available / Mestre
627

Avaliação clínica e da freqüência de ressonância, de implantes instalados por meio de técnica cirúrgica modificada na maxila e submetidos à função imediata /

Vasconcelos, Laércio Wonhrath. January 2005 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Banca: Marco Antonio Bottino / Banca: Carlos Eduardo Francischone / Banca: Waldyr Antonio Janson / Banca: Per-Ingvar Branemark / Resumo: Brånemark et al. (1969) introduziram os implantes osseointegrados como forma de ancoragem para próteses com intuito de substituir os dentes perdidos, tanto na mandíbula como na maxila. Desde então, foram instituídas modificações no protocolo clássico. Entre elas, a submissão dos implantes à função imediatamente após a sua instalação. Esse procedimento tem sido largamente estudado na mandíbula, com altos índices de sucesso, contudo, a literatura é escassa quanto à aplicação desta técnica na maxila. Propôs-se, então, avaliar a função imediata em implantes instalados em maxilas desdentadas totais, no momento da cirurgia e após seis e 12 meses de função. Para tanto foi utilizada uma técnica cirúrgica modificada e a avaliação da estabilidade dos implantes foi feita por meio da análise da freqüência de ressonância. Foram selecionados 10 pacientes, nos quais foram instalados seis implantes na maxila com a submissão dos mesmos à função imediata mediante a instalação de uma prótese fixa, com infra-estrutura metálica, 24 horas após a cirurgia. Estes pacientes foram acompanhados por um período de 12 meses. As medidas da estabilidade do implante foram realizadas no momento da instalação dos implantes (M0) e após seis (M6) e 12 meses (M12). Após o período de acompanhamento, foram obtidos índices de sucesso de 95% para os implantes e 90% para as próteses. Quanto aos valores da estabilidade dos implantes, foi observada uma diferença estatisticamente significativa entre os valores de M0 e M6, e, M0 e M12. Sendo o M0, o momento com maior valor do coeficiente de estabilidade. Não houve diferença estatisticamente significativa entre os valores da estabilidade obtidos no M6 e M12. Quando comparados, o valor da estabilidade para cada implante, não apresentaram diferença estatisticamente significativa no mesmo período de avaliação...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Brånemark et al. (1969) presented the osseointegrated implants as a way to anchorage prosthesis for missing teeth substitution in the jaws. Ever since, modifications in the classical protocol were instituted. Among them, the functional loading of the implants, immediately after their installation. This procedure have been well documented in mandibles, with high success levels, however, literature is scarce about the application of this technique in maxilla. The purpose of this study is to evaluate the immediate function in implants installed in totally edentulous maxillas, at the surgical moment and after six and 12 months of function. For so much, a modified surgical technique was used and implant stability was evaluated through the resonance frequency analysis. Ten patients were selected, who received six implants installed in the maxilla and submitted to immediate function. A metallic infra-structure fixed prosthesis was installed 24 hours after the surgery. The follow-up period was of 12 months. Implant stability measurements were taken at the surgical moment (M0) and after six (M6) and 12 months (M12). After the follow-up period, success rates of 95% for implants and 90% for prosthesis were achieved. As for the implant stability values, significant statistical difference were observed between M0 and M6, and M0 e M12, and no significant statistical difference was observed between M6 and M12. When the stability values of each implant was compared, no significant statistical difference was observed between them for different evaluation periods. It is concluded that the submission of implants, installed in the maxilla through a modified technique, to immediate function is a well predictable procedure, ever since well selected and executed. The resonance frequency analysis is an efficient method for the evaluation of the initial and late implants' stability. / Doutor
628

Comparação entre diferentes técnicas de moldagem utilizando transferentes específicos para implantes de hexágono interno : esquema "all-on-4" /

Silva, Lívia Amato Conceição Bueno da. January 2014 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: Mauro Antonio de Arruda Nóbilo / Banca: Gelson Luís Adabo / Resumo: O assentamento passivo é um dos pré-requisitos mais importantes na reabilitação oral sobre implantes com carga imediata e na manutenção da osseointegração. Devido à importância da obtenção de passividade no sucesso de reabilitações protéticas sobre implantes, da não observância de consenso sobre as técnicas de moldagens e da ausência de trabalhos que avaliem a moldagem em reabilitações baseadas no conceito "All-on-4", o presente estudo teve por objetivo analisar "in vitro" a precisão de diferentes métodos de moldagem em reabilitações protéticas sobre implantes de hexágono interno instalados em um modelo anatômico metálico de maxila desdentada. Foram variáveis do presente estudo a técnica de moldagem (Aberta, Fechada e Index) e os métodos de união dos transferentes (transferentes cônicos sem união, transferentes quadrados Inteligentes unidos com bastões de resina Pattern pré-fabricados e transferentes quadrados Inteligentes unidos com bastões metálicos, cianoacrilato e resina Pattern). Após a obtenção dos moldes (ExpressTM XT 3M/ESPE), foram produzidos quarenta modelos (4 grupos; n=10) sob espatulação mecânica à vácuo com gesso tipo IV (Fuji-Rock EP). Uma estrutura metálica confeccionada sobre o modelo mestre com assentamento passivo foi parafusada nos modelos obtidos, no análogo A enquanto foram feitas medições nos análogos C e D e quando parafusada no análogo D as medições foram feitas nos análogos A e B, por um programa (Leica QWin) que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa Leica (100X). Houve diferença significativa nas comparações entre as técnicas de moldagens e o modelo mestre, exceto para o grupo Quadrado Inteligente / Metal + Pattern (G2) com fenda média de 65 μm, sendo estatisticamente semelhante ao modelo mestre (60 μm). O grupo Index (G4) apresentou as menores desadaptações (38 μm). / Abstract:The passive fit is one of the most important prerequisites in oral rehabilitation on implants with immediate loading and maintenance of osseointegration. Due to the importance of obtaining passivity in the success of prosthetic rehabilitation on implants, the failure of consensus on the techniques of molding and the absence of studies that evaluate the molding rehabilitation based on the concept "All-on-4", the present study aims to analyze "in vitro" the accuracy of different methods of forming prosthetic rehabilitation in internal hexagon implant anatomical model installed in a metal jaw toothless. Variables in this study are the molding technique (Open, Closed and Index), transfer methods (conical transfer - no union and Intelligent square transfer), as well as methods of union of Intelligent square transfer (united Pattern resin sticks to prefabricated and joined together with metal sticks with cyanoacrylate resin and Pattern). After obtaining the molds (ExpressTM 3M/ESPE XT), forty models will be produced (4 groups; n=10) under mechanical vacuum mixing with type IV gypsum (Fuji-Rock EP). A metal structure fabricated on the master model with passive fit was screwed in the models obtained, on A analogue while measurements were made on analogs C and D and when screwed into analog D measurements were made in analogues A and B, by a program (Leica QWin) that received the images from a video camera coupled to a Leica (100X) loupe. There were significant differences in the comparisons between the techniques of molding and the master model, except for the Smart Square / Metal + Pattern (G2) with gap 65 μm, which behaved statistically similar to the master model group (60 μm). The Index group (G4) presented the less desadaptations (38 μm). / Mestre
629

Estudo das dimensões da papila gengival em áreas ântero superiores adjacentes a implantes unitários /

Perez, Fabiano. January 2006 (has links)
Resumo: O objetivo deste trabalho foi o de comparar as dimensões da papila gengival em áreas restauradas com implantes unitários e áreas com a dentição natural hígida. Além disso, verificou-se a influência da distância da crista óssea até o ponto de contato e da distância da plataforma do implante até a parede axial do dente adjacente sobre a extensão da papila gengival. Para isso, foram selecionados um total de 45 áreas proximais entre dentes naturais e 46 áreas proximais com a presença de implantes unitários. Os pacientes eram, então, submetidos a um exame clínico que tinha por objetivo a constatação da presença total, parcial, ou a ausência da papila gengival nas áreas examinadas. A papila gengival era então classificada em 4 níveis de altura: 0, quando estava totalmente ausente; 1 quando a papila ocupava menos da metade da distância da sua base até o ponto de contato; 2 quando a papila ocupava mais da metade dessa mesma distância, porém não preenchia totalmente o espaço interproximal; e 3 quando todo o espaço interproximal era ocupado pela papila gengival. Depois do exame clínico, os pacientes eram submetidos a tomadas radiográficas sendo que uma tela milimetrada era adaptada junto ao filme para que a imagem radiográfica obtida pudesse ser mensurada mais satisfatoriamente. Depois de obtidas as radiografias, as radiografias foram digitalizadas e as distâncias referentes ao estudo foram feitas por meio de um programa de computador. Com a análise dos dados obtidos, permitiu-se concluir que áreas anteriores superiores restauradas com implantes tendem a apresentar uma papila gengival com menor dimensão do que áreas de dentição natural. / Abstract: The purpose of this work was to compare the interproximal dental papilla dimension in areas restored with single implants and in areas of natural dentition. The effect of the distance from the contact point to the bone crest and of the distance from the implant platform to the axial face of the adjacent tooth on the papilla extension was also evaluated. Forty five interdental areas and 46 inter-implant areas were selected for the study. The presence (total or partial) or the absence of the interproximal papilla were examined and the following punctuations were made: 0 when the papilla was completely absence; 1 when the papilla filled less then half of the distance between its base and the contact point; 2 when the papilla filled more then half of that distance but not filled the entire of the interdental space; 3 when the whole interdental space was filled by the papilla. After the clinical examination, the patients were submitted to radiographic exams, using a radiographic grid adapted to the film to improve the measurements. The radiographs images were then digitized and the distances related to the study were measured using a computer software. From the data obtained, it was concluded that maxillary anterior areas restored with implants tend to present a smaller interdental papilla then areas of natural dentition. The distance from the contact point to the bone crest (height), the distance between adjacent roots in the natural dentition and the distance between the implant platform and the adjacent root (width) had significant influence on the presence or absence of the interproximal papilla in both groups evaluated. / Orientador: José Cláudio Martins Segalla / Coorientador: Elcio Marcantonio Junior / Banca: Paulo Martins Ferreira / Banca: José Mondelli / Banca: Regina Helena Barbosa T. da Silva / Banca: Francisco de Assis Mollo Junior / Doutor
630

Efetividade de parafusos com tratamento de superfície na estabilidade de pilares em zircônia após carga cíclica /

Basílio, Mariana de Almeida. January 2011 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Marcelo Mesquita Ferraz / Banca: José Maurício dos Santos Nunes Reis / Resumo: Com o objetivo de prevenir o afrouxamento, parafusos do pilar com lubrificantes sólidos de superfície foram desenvolvidos e introduzidos no mercado. Assim, foi proposto avaliar a efetividade de parafusos de liga de titânio com e sem tratamento de superfície sobre a estabilidade de pilares em zircônia (ZrO2) após carga cíclica, bem como observar alterações estruturais por meio de microscopia eletrônica de varredura (MEV). Para isso, 20 pilares UCLA em ZrO2 foram fixados sobre implantes do tipo hexágono externo com torque de 20 Ncm e divididos em 2 grupos (n=10), conforme o parafuso do pilar: (A) pilar-implante e parafuso de liga de titânio (Ti); (B) pilar-implante e parafuso de liga de titânio com cobertura Diamond Like Carbon (DLC/Ti). O valor do torque reverso (pré-carga) foi mensurado antes e após o carregamento. O teste foi realizado de acordo com a norma ISO 14801. Cargas cíclicas (0,5 x 106; 15 Hz) entre 11 - 211 N foram aplicadas com 30º de inclinação em relação ao longo eixo dos implantes. As médias dos grupos foram calculadas e comparadas utilizando análise de variância de dois fatores e testes F (α=0,05). Os resultados mostraram que antes do carregamento a média do grupo Ti foi significativamente maior que a do grupo DLC/Ti (p=0,021). Após o carregamento ambas as médias 14 diminuíram significativamente, sem diferença significante entre elas (p=0,499). As imagens obtidas na MEV revelaram micro-fraturas na base de assentamento do pilar. Nas condições estudadas, concluiu-se que: (1) os parafusos estudados apresentaram efetividade similar com relação à manutenção da pré-carga; (2) a redução significativa no torque reverso e os danos observados na MEV indicam que o acompanhamento dos pacientes é necessário para assegurar a longevidade das restaurações de ZrO2 implanto-suportadas. / Abstract: In an attempt to prevent screw-loosening problem, abutment screws with surface treatment were developed. Thus, the aim of the current study was to evaluate comparatively the effectiveness of titanium alloy coated screws and noncoated screws on the stability of ZrO2-ceramic abutments after cyclic loading, as soon as observe possible microdamaging in the structure of the components using a scanning electron microscope (SEM). For this, 20 prefabricated ZrO2-ceramic UCLA abutments were tightened to 20 Ncm on their respective external hex implants and divided equally into 2 groups (n=10), according to the type of screws used: (A) implant-abutment and noncoated titanium alloy screw (Ti); (B) implant-abutment and titanium alloy screw with Diamond Like Carbon surface coating (DLC/Ti). The reverse torque value (preload) of the abutment screw was measured before and after loading. The tests were performed according to ISO norm 14801. A cyclic loading (0,5 x 106; 15 Hz) between 11 - 211 N was applied at an angle of 30 degrees to the long axis of the implants. Group means were calculated and compared using ANOVA and F tests (α=0,05). The results showed that before cyclic loading, the mean of Ti group was significantly higher than the DLC/Ti group (p=0,021). After cyclic loading, both means decreased significantly, with no significant differences 16 between them (p=0,499). Under the studied conditions, it can be concluded that: (1) the two abutment screw types presented similar effectiveness in maintaining preload; (2) the significant decrease in reverse torque values and the microdamaging detected at SEM analysis indicate that patient follow-up is needed to ensure the integrity of the ZrO2-ceramic single-implant restorations. / Mestre

Page generated in 0.0179 seconds