• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 102
  • 79
  • 54
  • 32
  • 13
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 886
  • 160
  • 130
  • 97
  • 85
  • 81
  • 75
  • 74
  • 72
  • 67
  • 59
  • 57
  • 53
  • 51
  • 48
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
731

Étude expérimentale et numérique de la fissuration intralaminaire dans les composites à hautes performances / Experimental and Numeriacal Studies of Intralaminar Cracking in High Performance Composites

Loukil, Mohamed Sahbi 04 October 2013 (has links)
Le mécanisme d'endommagement le plus facilement observable lors d'un essai de traction est la micro-fissuration des plis. Ces fissures sont parallèles à la direction des fibres et s'étendent sur toute l'épaisseur du pli. L'apparition et la croissance du nombre de ces fissures engendrent une réduction progressive de la rigidité globale du composite. Lorsque le composite est sollicité mécaniquement, les concentrations de contraintes en pointe de fissures peuvent favoriser la création d'une zone où le pli fissuré et le pli adjacent sont décollés (phénomène de délamination). Il est évident que l'apparition de cette nouvelle forme d'endommagement modifiera la dépendance de l'ouverture et du glissement des lèvres des fissures avec le chargement appliqué. Il est donc nécessaire de trouver un moyen de mesure permettant l'estimation expérimentale des valeurs de l'ouverture moyenne et du glissement moyen des lèvres des fissures. L'objectif principal de cette thèse est de caractériser l'endommagement des matériaux composites (Fibre de carbone/époxy et fibre de verre/époxy) utilisés dans le domaine aéronautique. En utilisant l'interférométrie de speckle (ESPI), des mesures de plein champs de déplacements aux bords des échantillons et dans différentes couches du stratifié ainsi que des études par élément finis ont été effectuées dans le but de calculer l'ouverture et le glissement des lèvres des fissures. L'effet des propriétés élastiques des matériaux sur l'endommagement aussi bien que l'effet d'interaction entre les fissures ont été déterminés. Une discussion essais/calculs est enfin réalisée afin de juger la validité des hypothèses retenues / The macroscopic failure of composite laminates subjected to tensile increasing load is preceded by initiation and evolution of several microdamage modes. The most common damage mode and the one examined in this thesis is intralaminar cracking in layers. Due to this kind of microdamage the laminate undergoes stiffness reduction when loaded in tension. The degradation of the elastic properties of these materials is caused by reduced stress in the damaged layer which is mainly due to two parameters: crack opening displacement (COD) and crack sliding displacement (CSD). The first objective of this thesis is to investigate the effect of crack interaction on COD using FEM and to describe the identified dependence on crack density in a simple and accurate form by introducing an interaction function dependent on crack density. The application of this function to more complex laminate lay-ups is demonstrated. All these calculations are performed assuming that cracks are equidistant. Using FEM, we assume linear elastic material with ideal crack geometry. Fiber bridging over the crack surface is possible which can affect COD and CSD. The only correct way to validate these assumptions is through experiments. The second objective is to measure these parameters for different laminate lay-ups in this way providing models with valuable information for validation of used assumptions and for defining limits of their application. In particular, the displacement field on the edge of a [90/0]s and [903/0]s carbon fiber/epoxy laminates specimens with multiple intralaminar cracks in the surface layer is studied
732

Coronographie à masque adaptatif pour imagerie et détection à haute dynamique / Adaptive Mask Coronagraph for High Dynamic Range Imaging and Detection

Bourget, Pierre 05 December 2014 (has links)
L’imagerie à très haute dynamique s’applique à de nombreux domaines de recherche en astronomie et astrophysique. Cette problématique observationnelle est abordée sur plusieurs fronts par de nombreuses techniques complémentaires : coronographie, interferométrie, optique adaptative, controle de front d’onde et discrimination des speckles. La combinaison de celles ci permet d’atteindre un haut contraste avec pour ultime objectif l’imagerie d’exoplanètes et l’étude de l’environnement stellaire. Le travail présenté dans ce manuscrit se focalise sur la coronographie et plus particulièrement sur l’optimisation active du procedé d’occultation en fonction du contexte observationnel.La première partie de cette recherche traite de l’observation d’objets résolus par le développement d’un masque focal de Lyot de diamètre variable. La deuxième partie s’applique à étendre le concept du masque focal adaptatif au masque de phase de type Roddier pour l’observation de l’environnement proche d’objets non résolus. L’utilisation des propriétés des cristaux liquides permet de réaliser un déphasage par rotation de polarisation et une modulation de transmission à l’extérieur du masque. Cette modulation permet un controle actif d’optimisation de l’interférence pour une adéquation du masque au contexte observationnel : longueur d’onde, morphologie d’image et défauts intrinsèques au masque, agitation atmosphérique. La dernière partie de ce manuscrit ébauche de nouvelles perspectives quant à la possibilité d’une imagerie à haut contraste. La modulation temporelle de phase transmise par un masque focal adaptatif est mise à profit par l’utilisation des méthodes de détection synchrone. / High contrast imaging of extra-solar planets and environments of bright astro- physical objects in general, such as stars, active galactic nuclei or objects of the Solar System is a challenging task. Different approaches are needed if the bright region to occult is optically resolved or not. We present the Adaptive Mask concept, observations on sky and numerical simulations show the usefulness of the proposed methods to optimize the efficiency of the coronagraphs for optically resolved or non resolved objects. Accessing small IWA is considered as an edge as it provides substantial scientific and technical advantages. One of the difficulties of accessing small IWA is that coronagraphs become very sensitive to low-order aberrations such as tip-tilt. Our original approach aims at integrating the small IWA capability and the mitigation of sensitivity to low-order aberrations within the coronagraph itself. Our concept is applicable to both low and high Strehl regimes, corresponding to current and next generation AO systems. The adaptive coronagraph can adapt dynamically, in quasi real time, to adjust to the observing conditions to deliver a stable and optimized contrast at the science image level. The mask adaptability both in size, phase and amplitude also compensates for manufacturing errors of the mask itself, and potentially for chromatic effects. The mask adaptability concept using a local phase modulation in the focal plane allows synchronous modulation for high dynamic range synchronous detection of a faint target immersed in a background. The coherence of the speckles with the central star is used to discriminate them from proper companions.
733

Metodologia para medição de tensões em virabrequins utilizando ESPI / Stress measurements in crankshafts using ESPI

Matsusaki, Eduardo Hiroshi 18 August 2018 (has links)
Orientador: Auteliano Antunes dos Santos Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-18T19:03:51Z (GMT). No. of bitstreams: 1 Matsusaki_EduardoHiroshi_M.pdf: 16938577 bytes, checksum: 51152fe274507619364344f4ec28e4b9 (MD5) Previous issue date: 2009 / Resumo: Tensões mecânicas estão entre as principais causas de falhas de componentes estruturais. A medição de tais tensões pode ser feita com técnicas que relacionam alguma variável física a tensão existente. Técnicas destrutivas podem ser usadas para tal finalidade, mas apenas no controle de qualidade. Entre as técnicas não destrutivas destacam-se os Raios X, a difração de Nêutrons e a acustoelasticidade. Uma das técnicas mais promissoras envolve a Interferometria a Laser. Segundo essa técnica, a interferência entre feixes de luz permite a identificação de pontos da superfície e estes, quando deslocados sob a aplicação de esforços, possibilitam o cálculo das deformações e tensões. Este trabalho apresenta a aplicação da técnica de Interferometria Eletrônica entre Padrões de Speckles - ESPI para a medição de tensões em virabrequins. O estudo consistiu em uma revisão teórica do método; no estudo dos fatores que influenciam o resultado da medição; na validação da técnica para a medição de tensões, através da comparação com resultados do MEF e da extensometria; na aplicação da técnica para a medição cm chapa entalhada e no emprego desta para a medição de tensões em virabrequins. O estudo permitiu também a ajustagem ótima dos parâmetros que influenciem a medição. Os resultados obtidos mostraram que o método é promissor quanto ao seu emprego generalizado; que a resolução obtida é adequada para o emprego na medição nos componentes analisados e que o método tem limitações importantes, que devem ser avaliadas para cada aplicação / Abstract: Mechanical stresses are among the main causes of failure of structural components. The measurement of such stresses can be made with techniques that relate some physical variable with the stress. Destructive techniques can be used for this purpose, but only in quality control. Non-destructive methods such as the X rays, the neutron diffraction and acoustoelasticity, are among the most used techniques. One of the most promising techniques applies Laser Interferometry. In this technique, the interference between light beams identifies points on the surface and these, when displaced under external forces, enable the calculation of the deformations and of the stresses. This paper presents the employ of the Electronic Speckle Pattern Interferometry technique for measuring stresses in crankshafts. It consisted of a theoretical review of the method; the study of the factors that would compromise the measuring results; a validation of the technique to measure stresses, by comparing MEF with strain gauges results; using the technique to take measures in a entailed plate and in the stresses measurements of crankshafts. This work also allowed the optimum adjustment for the parameters inducing the measurements. The obtained results showed a promising method for its general use; showed too that the resolution obtained is proper to the use in parts analyzed and that the method has important limitations that should be analyzed in every situation / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
734

Stérilisation de dispositifs médicaux ensachés par plasmas froids basse pression / Low pressure plasma sterilization of packaged medical devices

Maho, Thomas 19 December 2016 (has links)
Dans le domaine médical, l’évolution des techniques et des technologies ainsi que l’apparition de nouveaux matériaux ont favorisé le développement de dispositifs médicaux (DM) toujours plus performants et légers. Certains de ces matériaux sont difficilement stérilisables de par leur fragilité aux agents stérilisants (physiques ou chimiques). De nombreuses études ont montré l’efficacité des plasmas froids sur des souches bactériennes pathogènes mais le maintien à l’état stérile des DM fragiles et sensibles à la température reste un verrou technique à lever. Cette thèse CIFRE s’inscrit dans le cadre du projet ANR PLAS’STER. Il vise à développer un procédé industriel pouvant répondre à une certification comme stérilisateur par plasmas froids basse pression. Le caractère innovant réside en la création et au confinement d’un plasma à l’intérieur d’un sac de stérilisation assurant la préservation de l’état stérile du DM stérilisé. Une première partie a été consacrée à la caractérisation physique des décharges plasmas confinées dans le sac de stérilisation. Cette étude a permis d’identifier les espèces potentiellement bactéricides et de définir des conditions favorables à leur production. Dans un second temps, l’efficacité bactéricide du procédé a été démontrée sur des bactéries à Gram négatif et à Gram positif selon la norme EN556. En parallèle, l’étude paramétrique réalisée sur E. coli a apporté des éléments de réponse sur les mécanismes de stérilisation et a ouvert des pistes sur l’optimisation du procédé. Enfin, l’analyse post-traitement des propriétés de biomatériaux a démontré l’absence de modifications macromoléculaires et a validé la potentialité du procédé PLAS’STER comme alternative aux méthodes usuelles de stérilisation. / Standard sterilization methods such as autoclave, ethylene oxide or irradiation can affect the biocompatibility of medical devices, especially those sensitive to heat or chemicals products. Numerous studies have demonstrated the possibility to use low pressure plasmas as an alternative sterilization process: low process temperature, treatment time competitive to autoclave and without any toxic agent. However, the sterile state preservation is still a problem. In the framework of the ANR PLAS'STER project, this CIFRE thesis focus on a new sterilization process development based on low pressure cold plasmas. The innovation resides in the creation and the confinement of a plasma inside a sterilization bag, thereby ensuring the conservation of the sterile state. The first part was dedicated to the physical characterization of the plasmas discharges confined inside the bag of sterilization. Secondly, the bactericidal efficiency of the process was demonstrated on Gram negative and Gram positive bacteria according to the EN556 standard. Additional tests on E. coli lead to hypothesis on the sterilization mechanisms and opened tracks on the optimization of our process. Finally, the properties analysis of biomaterials demonstrated the absence of macromolecular modifications and validated the potentiality of the process PLAS' STER as the sterilization method alternative.
735

Smart plasmonic Lab-On-a-Chip System for DNA-based biosensing / Bio-détection plasmonique à ADN sur laboratoire sur puce

Wu, Tzu-Heng 20 March 2017 (has links)
Dans cette thèse, nous nous intéressons à la problématique de l’intégration de capteurs plasmoniques performants et bas coût sur des dispositifs de type smartphone, en vue d’applications de diagnostic biomédical. A cette fin, nous proposons deux biocapteurs « smart ». Premièrement, un système de détection colorimétrique à base de nanoparticules d’or est mis en œuvre pour détecter de l’ADN. Le système intègre une détection synchrone logicielle mise en œuvre au sein du smartphone, où les signaux physiques transitent par la voie audio. Le processus de diagnostic prend moins de 15 minutes pour une limite de détection de 0.77 nM, approximativement 6 fois meilleure que la sensibilité usuelle d’un spectromètre UV-Vis conventionnel, à temps de mesure identique. Dans une seconde partie, un capteur à résonance plasmon de surface en configuration de Kretschmann, se distinguant par une sensibilité à la phase optique, est développé. Le design monolithique et compact repose sur un interféromètre à dédoublement latéral et une modulation de phase. Le contrôle et la lecture du prototype s’effectue également par smartphone. La modulation de phase est de type sinusoïdale et une sensibilité importante est obtenue, autour de 2,3 10-6 RIU avec une dynamique de 7 10-3 RIU, chiffres obtenus pour une puce optique standard et un temps d’intégration de 100 ms. Ce second dispositif est ensuite testé pour la détection de protéines (Troponine I cardiaque), en fonctionnalisant la surface par ADN Tro4 / In this thesis, we investigate the possibility and potential for integration of portable optical biosensor for diagnostic purposes. To this end, we propose two “smart” biosensor systems. In the first part of this thesis, a DNA biosensor combining single-wavelength colorimetry and digital Lock-in Amplifier within a smartphone is proposed. Utilizing full advantage of audio channel and digital signal processing capacity of a smartphone, we have built a handheld DNA AuNp colorimetry biosensor. Based on the results, the diagnostic process takes only 15 minutes of reaction time while offering a limit of detection around 0.77 nM which is 6 times better than a desktop UV-Vis spectrometer.In second part of the thesis, a Shearing interferometer based Surface Plasmon Resonance (SiSPR) biosensor is proposed. SiSPR allows for phase sensitive detection on conventional Kretschmann configuration. Its monolithic design reduces optical parts, costs and allows portable application. The essence of SiSPR is a reflective layer in addition to plasmonic layer. To extract phase information from SiSPR, a sinusoidal phase modulation is achieved by modulation of the laser injection current. For a 100 ms measurement and a standard optical chip, the sensitivity of the SiSPR is around 2.3x10-6 RIU with a dynamic range of 7.0x10-3 RIU, which is better than amplitude SPR devices. Finally, Tro4 DNA surface modification on the SiSPR chip is demonstrated for future cardiac Troponin I diagnostic
736

Acquisition comprimée multi-longueur d'onde et son application en radioastronomie / Multichannel Compressed Sensing and its Application in Radioastronomy

Jiang, Ming 10 November 2017 (has links)
La nouvelle génération d’instrument d’interféromètre radio, tels que LOFAR et SKA, nous permettra de construire des images radio à haute résolution angulaire et avec une bonne sensibilité. L’un des problèmes majeurs de l’imagerie interférométrie est qu’il s’agit d’un problème inverse mal posé car seulement quelques coefficients de Fourier (visibilités) peuvent être mesurés par un interféromètre radio. La théorie de l’Acquisition Comprimée (Compressed Sensing) nous permet d’envisager ce problème sous un autre angle et son efficacité pour la radioastronomie a été montrée. Cette thèse se concentre sur la méthodologie de la reconstruction de données à l’Acquisition Comprimée Multicanaux et son application en radioastronomie. Par exemple, les transitoires radios sont un domaine de recherche actif en radioastronomie, mais leur détection est un problème difficile en raison de la faible résolution angulaire et des observations à faible rapport signal-sur-bruit. Pour résoudre ce problème, nous avons exploité la parcimonie de l’information temporelle des transitoires radios et nous avons proposé une méthode de reconstruction spatio-temporelle pour détecter efficacement les sources radios. Les expériences ont démontré la force de cette méthode de reconstruction en comparaison avec les méthodes de l’état de l’art. Une deuxième application concerne l’imagerie interférométrie radio à multi-longueur d’onde dans lesquelles les données sont dégradées différemment en termes de longueur d’onde car la réponse instrumentale varie en fonction de la longueur d’onde. Basé sur le modèle de mélange de sources, un nouveau modèle est proposé pour effectuer de manière jointe une Séparation de Sources en Aveugle et une déconvolution (SSAD). Le problème SSAD n’est pas seulement non-convexe mais aussi mal conditionné en raison des noyaux de convolution. Notre méthode proposée DecGMCA, qui utilise un a priori de parcimonie et emploie un scénario de moindre carré alternatif, est un algorithme efficace pour aborder simultanément les problèmes de déconvolution et de SSA. Les expériences ont démontré que notre approche jointe permet d’obtenir de meilleurs résultats comparée à une analyse standard consistant en une application séquentielle d’une déconvolution suivie d’une séparation de sources en aveugle. / The new generation of radio interferometer instruments, such as LOFAR and SKA, will allow us to build radio images with very high angular resolution and sensitivity. One of the major problems in interferometry imaging is that it involves an ill-posed inverse problem, because only a few Fourier components (visibility points) can be acquired by a radio interferometer. Compressed Sensing (CS) theory is a paradigm to solve many underdetermined inverse problems and has shown its strength in radio astronomy. This thesis focuses on the methodology of Multichannel Compressed Sensing data reconstruction and its application in radio astronomy. For instance, radio transients are an active research field in radio astronomy but their detection is a challenging problem because of low angular resolution and low signal-to-noise observations. To address this issue, we investigated the sparsity of temporal information of radio transients and proposed a spatial-temporal sparse reconstruction method to efficiently detect radio sources. Experiments have shown the strength of this sparse recovery method compared to the state-of-the-art methods. A second application is concerned with multi-wavelength radio interferometry imaging in which the data are degraded differently in terms of wavelength due to the wavelength-dependent varying instrumental beam. Based on a source mixture model, a novel Deconvolution Blind Source Separation (DBSS) model is proposed. The DBSS problem is not only non-convex but also ill conditioned due to convolution kernels. Our proposed DecGMCA method, which benefits from a sparsity prior and leverages an alternating projected least squares, is an efficient algorithm to tackle simultaneously the deconvolution and BSS problems. Experiments have shown that taking into account joint deconvolution and BSS gives much better results than applying sequential deconvolution and BSS.
737

Interférométrie Simultanée avec Deux Espèces Atomiques ⁸⁷Rb/⁸⁵Rb et Applications aux Mesures Inertielles / Simultaneous Interferometry with Two Atomic Species ⁸⁷Rb/⁸⁵Rb and Applications to Inertial Measurements

Bonnin, Alexis 23 November 2015 (has links)
Dans la problématique émergente des expériences visant à tester le Principe d'Équivalence à l'aide de capteurs inertiels à atomes froids, cette thèse porte sur la réalisation et la caractérisation d'un interféromètre atomique double espèce simultané (⁸⁷Rb et ⁸⁵Rb) qui permet l'obtention d'une mesure extrêmement sensible de l'accélération différentielle. L'interféromètre, de type Mach-Zehnder, repose sur la manipulation simultanée des ondes de matière atomiques à l'aide de transitions Raman stimulées. Le système laser est basé sur le doublage en fréquence d'une unique source laser à 1560 nm. L'ensemble des fréquences lasers requises pour la manipulation des deux isotopes (piégeage, refroidissement, sélection, interférométrie et détection) sont générées par modulation en phase de cette source. Une modélisation détaillée des réponses inertielles de l'interféromètre ainsi que l'analyse d'une méthode d'extraction de la phase différentielle à partir du signal elliptique ont été menées. La mesure de l'accélération différentielle a conduit à un test atomique du Principe d'Équivalence Faible de η(⁸⁷Rb,85Rb) = (1.3 ± 3.2) × 10⁻⁷, à l'état de l'art. L'aspect simultané de la mesure a permis de mettre en évidence la réjection du bruit de vibration par effet de mode commun pour la première fois avec deux espèces différentes, le facteur de réjection étant aujourd'hui de 50 000. Les performances actuelles de l'instrument sur la mesure d'accélération différentielle montrent une sensibilité de 1.23×10⁻⁷g/√Hz et une résolution de 2×10⁻⁹g pour des temps d'intégration inférieurs à quelques heures. Pour finir, des modes de fonctionnement innovants d'interféromètres atomiques double espèce pour la mesure d'accélération embarquée sont explorés. / In the emerging issue of testing the Equivalence Principle with cold atom inertial sensors, this thesis focuses on the realization and the characterization of a simultaneous dual-species atom interferometer (⁸⁷Rb & ⁸⁵Rb) which allows to measure the differential acceleration in an extremely sensitive way. The Mach-Zehnder type atom interferometer relies on the simultaneous handling of atomic wave-packets with stimulated Raman transitions. The laser system is based on the frequency doubling of a single laser source at 1560 nm. All the required laser frequencies for handling both isotopes (trapping, cooling, selection, interferometry and detection) are generated by phase modulating this source. A detailed modeling of the interferometer's inertial responses and an analysis of a method to extract the differential phase were carried out. The differential acceleration measurement led to an atom based test of the Weak Equivalence Principle of η(⁸⁷Rb,85Rb) = (1.3 ± 3.2)×10⁻⁷, at the state-of-the-art. The simultaneous aspect of the experiment allowed to highlight for the first time common mode vibration noise rejection with two different atomic species, a rejection factor of 50 000 being currently achieved. The current performance of the instrument exhibits a sensitivity on the differential acceleration of 1.23 × 10⁻⁷g/√Hz and a resolution of 2 × 10⁻⁹g for integration times lower than few hours. Finally, innovative operating modes of dual-species atom interferometers for on-board acceleration measurements are explored.
738

Détection et caractérisation d’exoplanètes : développement et exploitation du banc d’interférométrie annulante Nulltimate et conception d’un système automatisé de classement des transits détectés par CoRoT / Detection and characterisation of exoplanets : development and operation of the nulling interferometer testbed Nulltimate and design of an automated software for the ranking of transit candidates detected by CoRoT

Demangeon, Olivier 28 June 2013 (has links)
Parmi les méthodes qui permettent de détecter des exoplanètes, la photométrie des transits est celle qui a connu le plus grand essor ces dernières années grâce à l’arrivée des télescopes spatiaux CoRoT (en 2006) puis Kepler (en 2009). Ces deux satellites ont permis de détecter des milliers de transits potentiellement planétaires. Étant donnés leur nombre et l’effort nécessaire à la confirmation de leur nature, il est essentiel d’effectuer, à partir des données photométriques, un classement efficace permettant d’identifier les transits les plus prometteurs et qui soit réalisable en un temps raisonnable. Pour ma thèse, j’ai développé un outil logiciel, rapide et automatisé, appelé BART (Bayesian Analysis for the Ranking of Transits) qui permet de réaliser un tel classement grâce une estimation de la probabilité que chaque transit soit de nature planétaire. Pour cela, mon outil s’appuie notamment sur le formalisme bayésien des probabilités et l’exploration de l’espace des paramètres libres par méthode de Monte Carlo avec des chaînes de Markov (mcmc).Une fois les exoplanètes détectées, l’étape suivante consiste à les caractériser. L’étude du système solaire nous a démontré, si cela était nécessaire, que l’information spectrale est un point clé pour comprendre la physique et l’histoire d’une planète. L’interférométrie annulante est une solution technologique très prometteuse qui pourrait permettre cela. Pour ma thèse, j’ai travaillé sur le banc optique Nulltimate afin d’étudier la faisabilité de certains objectifs technologiques liés à cette technique. Au-delà de la performance d’un taux d’extinction de 3,7.10^-5 en monochromatique et de 6,3.10^-4 en polychromatique dans l’infrarouge proche, ainsi qu’une stabilité de σN30 ms = 3,7.10^-5 estimée sur 1 heure, mon travail a permis d’assainir la situation en réalisant un budget d’erreur détaillé, une simulation en optique gaussienne de la transmission du banc et une refonte complète de l’informatique de commande. Tout cela m’a finalement permis d’identifier les faiblesses de Nulltimate. / From all exoplanet detection methods, transit photometry went through the quickest growth over the last few years thanks to the two space telescopes, CoRoT (in 2006) and Kepler (in 2009). These two satellites have identified thousands of potentially planetary transits. Given the number of detected transits and the effort required to demonstrate their natures, it is essential to perform, from photometric data only, a ranking allowing to efficiently identify the most promising transits within a reasonable period of time. For my thesis, I have developed a quick and automated software called bart (Bayesian Analysis for the Ranking of Transits) which realizes such a ranking thanks to the estimation of the probability regarding the planetary nature of each transit. For this purpose, I am relying on the Bayesian framework and free parameter space exploration with Markov Chain Monte Carlo (mcmc) methods.Once you have detected exoplanets, the following step is to characterise them. The study of the solar system demonstrated, if it was necessary, that the spectral information is a crucial clue for the understanding of the physics and history of a planet. Nulling interferometry is a promising solution which could make this possible. For my thesis, I worked on the optical bench Nulltimate in order to study the feasibility of certain technological requirements associated with this technique. Beyond the obtention of a nulling ratio of 3,7.10^-5 in monochromatic light and 6,3.10^-4 in polychromatic light in the near infrared, as well as a stability of σN30 ms = 3,7.10^-5 estimated on 1 hour, my work allowed to clarify the situation thanks to a detailed error budget, a simulation of the transmission based on Gaussian beam optics and a complete overhaul of the computer control system. All of this finally resulted in the identification of the weaknesses of Nulltimate.
739

Elastohydrodynamic Film Study under Impact Loading and Lateral Vibrations / Elastohydrodynamic Film Study under Impact Loading and Lateral Vibrations

Frýza, Josef January 2018 (has links)
Disertační práce se zabývá chováním a odezvou elastohydrodynamického (EHD) mazacího filmu za neustálených provozních podmínek. V úvodní části práce jsou shrnuty poznatky z oblasti EHD mazání; od jeho historie, přes základní mechanismy mazání a používané experimentální metody, až po nedávno publikované studie zaměřené na transientní podmínky. Hlavním cílem práce bylo experimentálně objasnit vliv provozních parametrů a reologických vlastností maziv na chování mazacího filmu v bodovém kontaktu při jeho nárazovém zatěžování a vystavení příčným vibracím. Za tímto účelem byla vyvinuta laboratorní zařízení umožňující měření rozložení mazacího filmu a tření za kontrolovaných nestacionárních podmínek. Experimenty odhalili zásadní roli přibližovacích a zatěžovacích rychlostí na formování stlačených mazacích filmů při nárazovém zatěžování. Výsledky byly srovnávány s nedávným teoretickým řešením. Bylo ukázáno na jeho nedostatky, jež byly následně odstraněny implementací empirických vztahů zohledňujících reologii maziv. V případě příčných vibrací byly nalezeny hranice selhání mazacího filmu a určeny vztahy popisující vliv příčných vibrací na centrální tloušťku filmu a její fluktuace jednotně pro všechny maziva. Závěrečná část práce poskytuje nový pohled na reologii maziv pomocí inovativního přístupu měření třecích reakcí maziva současně ve dvou směrech kontaktu za podmínek příčných vibrací. Tyto původní výsledky rozšiřují pochopení mechanizmů EHD mazání a mohou být použity k dokonalejším návrhům strojů, a vylepšit tak jejich účinnost, spolehlivost a životnost.
740

Distribuované optické vláknové senzory / Distributed fiber optic sensors

Holík, Tomáš January 2018 (has links)
The thesis deals with the possibility of using optical fiber as a sensor. The introduction of the thesis is devoted to the foundations of optics. In addition, the thesis deals with optical interferometry, polarization and dispersion in optical fiber. The main output of the thesis is the comparison of acoustic vibration measurements using interferometric and polarization methods and further measurements on the real route in Brno.

Page generated in 0.0315 seconds