• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo dos desvios geométricos gerados na obtenção de biomodelos a partir de imagens tomográficas

Kunzler, Maria Regina January 2008 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Metrologia Científica e Industrial. / Made available in DSpace on 2012-10-24T04:28:47Z (GMT). No. of bitstreams: 1 256475.pdf: 2222215 bytes, checksum: ac6b5483853603fd1b72967e56ec175c (MD5)
2

Contribuição para a funcionalidade e a segurança em ressonância magnética

Moraes, Luciano de January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-20T12:02:05Z (GMT). No. of bitstreams: 1 194333.pdf: 2949848 bytes, checksum: a7282fef57b3415b8ba706a28566ade0 (MD5) / A imagem por ressonância magnética (IRM) apresenta no Brasil um crescente potencial de aplicações ainda não totalmente explorado. Por causa disto, torna-se necessário assegurar as condições da funcionalidade com o enfoque na qualidade da imagem, técnica e clínica, e da segurança ao paciente e funcionários envolvidos nos serviços de IRM. Este trabalho tem como objetivo, proporcionar um aporte para a Engenharia Clínica (EC) na gestão de tecnologia médico-hospitalar (GTMH), através da elaboração de uma proposta de metodologia que permita verificar as condições da qualidade da imagem e da segurança nos serviços de IRM e, de referencial teórico em futuras elaborações de procedimentos de ensaios. Primeiramente, discutem-se as características necessárias para a qualidade da imagem e, depois, abordam-se os aspectos de segurança, analisando-se a literatura técnica e a norma internacional IEC 60601-2-33:2002 (Particular requirements for the safety of magnetic resonance equipment for medical diagnosis). Com os resultados obtidos na aplicação da metodologia em um estabelecimento assistencial de saúde (EAS) de Santa Catarina, percebeu-se que a metodologia proposta mostra-se útil na avaliação qualitativa do uso dessa tecnologia, por fornecer um diagnóstico geral dos ensaios, calibrações, recursos humanos e políticas de segurança empregados pela instituição e, por permitir identificar ações para a melhoria desses serviços, caracterizando um dos aspectos da GTMH.
3

Uma contribuição ao controle de qualidade de gamacâmeras

Oliveira, Fernanda Ramos de January 2000 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-18T00:42:30Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T18:38:05Z : No. of bitstreams: 1 175067.pdf: 3456208 bytes, checksum: 81c6abceeb748b3ef6355799a0e6e6c2 (MD5) / A verificação da linearidade e da resolução intrínseca de gamacâmeras é feita através da análise da imagem de um fantoma de barras (dispositivo padrão proposto por norrnas para realização deste teste). Este trabalho propõe que a imagem seja digitalizada, através de um scanner específico para filmes radiográficos, e avaliada através de um programa de computador. A sistemática proposta não exige que nenhum equipamento ou dispositivo complementar seja acrescentado à gamacâmera. Apenas a imagem, obtida segundo os procedimentos já previstos da norma, é analisada pelo computador. Isto permite a aplicação da sistemática a qualquer serviço de medicina nuclear. 0 programa foi avaliado quanto à sua repetitividade, sensibilidade ao posicionamento e alinhamento da imagem, aos parâmetros do sistema de digitalizagiio (scanner), do forrnato de compactação das imagens e número de imagens envolvidas. Também foi feita uma comparação entre a resolução intrínseca obtida através do método proposto pela CNEN, na norma CNEN-NE-3.05, e pelo programa criado.
4

Configuração do trato vocal supraglótico na produção das vogais do português brasileiro: dados de imagens de ressonância magnética / Supraglottic vocal tract shaping in the production of brazilian portuguese vowels: data from magnetic resonance imaging

Gregio, Fabiana Nogueira 05 May 2006 (has links)
Made available in DSpace on 2016-04-28T18:23:13Z (GMT). No. of bitstreams: 1 FABIANA NOGUEIRA GREGIO.pdf: 4764922 bytes, checksum: 3bc99038173d40cffe0691bbd4f49e0d (MD5) Previous issue date: 2006-05-05 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / To characterize the supraglottic vocal tract shaping in the production of the seven oral and five nasal vowels of brazilian portuguese from the articulatory point of view by means of magnetic resonance imaging (MRI). Methods: The subject of this study, one female native speaker of brazilian portuguese, had no previous alterations of speech, language or of neurological and auditory systems and with neither dental nor articulator alterations. The magnetic resonance images, collected during the production of the vowels sustained by the speaker, were analyzed for articulatory characterization. The results were considered according to articulatory and acoustic data researched in the related literature. Results and discussion: The nasal vowels, unlike the oral ones, presented three different moments, which are characterized by changes in the position of the articulators during their production; while the oral vowels presented only one moment/phase. The oral vowels, when compared to the nasal, maintained similar characteristics, being articulatorily classified by the position of their tongue-surface (both vertically and horizontally), by the opening of the oral cavity, by the rounding of the lips and by the position of the soft palate. The vowels that presented the greater differences, when compared to their oral and nasal counterparts, were [a]-[ã], [o]-[õ] and [u]-[uâ]. Production of nasal vowels took a longer time than their oral counterparts yielding a larger number of frames captured. Conclusion: Data obtained by means of MRI has allowed the analysis of the movements of the articulators during the production of the vowels contributing to: increasing the knowledge of brazilian portuguese vowels production mechanisms; characterizing the brazilian portuguese vowels inventory; providing insights to the evaluation and rehabilitation of speech disorders / Caracterizar a configuração do trato vocal supraglótico na produção das sete vogais orais e cinco nasais do português brasileiro do ponto de vista articulatório por meio de imagens de ressonância magnética (IRM). Métodos: Atuou como sujeito da pesquisa, um falante do gênero feminino nativo do português brasileiro, com histórico negativo para alterações de fala, linguagem e dos sistemas neurológico e auditivo e ausência de alterações dentárias e de articuladores. As imagens de ressonância magnética, coletadas durante a produção das vogais sustentadas pelo falante, foram analisadas para caracterização articulatória. Os resultados foram considerados em relação aos dados articulatórios e acústicos pesquisados na literatura. Resultados e discussão: As vogais nasais, ao contrário das orais, apresentaram três momentos distintos, caracterizados por mudanças no posicionamento dos articuladores durante sua emissão; enquanto que as vogais orais apresentaram apenas um momento/fase. As vogais orais, quando comparadas com as nasais, mantiveram características semelhantes, sendo classificadas articulatoriamente pelo posicionamento do dorso de língua (no sentido vertical e horizontal), pela abertura da cavidade oral, pelo arredondamento labial e pelo posicionamento do palato mole. As vogais que apresentaram maior modificação, quando comparadas entre suas correspondentes oral e nasal, foram [a]-[ã], [o]-[õ] e [u]-[uâ]. As vogais nasais revelaram um tempo maior que suas correspondentes orais obtendo um maior número de quadros capturados. Conclusão: Os dados obtidos por meio de IRM permitiram analisar os movimentos dos articuladores durante a produção das vogais contribuindo para: ampliação do conhecimento dos mecanismos de produção das vogais do português brasileiro; caracterização do inventário de vogais do português brasileiro; e reflexões na avaliação e reabilitação das alterações de fala

Page generated in 0.1139 seconds