• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 14
  • 12
  • 12
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Resultado reagente próximo ao limiar de reaticidade: uma dificuldade no diagnóstico laboratorial da hepatite C

Ramos, Marcos Montanha [UNESP] 02 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-02Bitstream added on 2014-06-13T18:09:20Z : No. of bitstreams: 1 ramos_mm_me_botfm.pdf: 505331 bytes, checksum: c19ab9911d5a9bf7f687fb2f2987b64d (MD5) / Ministério da Saúde / Fundação para o Desenvolvimento Médico e Hospitalar (Famesp) / Secretaria do Estado da Saúde de São Paulo / O fluxograma de investigação laboratorial da hepatite C, proposto pelo Ministério da Saúde, envolve a utilização de metodologias que pesquisam anticorpos anti-VHC como testes de triagem para a infecção, sendo que os testes moleculares vêm sendo utilizados como confirmatórios mediante sorologia positiva. Neste fluxo, algumas amostras podem apresentar, nos testes de triagem, resultados reagentes próximos ao limiar de reatividade e estes resultados muitas vezes não se confirmam quando se utilizam outras metodologias. Estes resultados falso-positivos podem gerar descarte de bolsas de sangue e conseqüências psicológicas negativas para doadores e pacientes. Assim, o objetivo deste estudo foi estabelecer valores de corte entre resultados reagentes e fracamente reagentes no diagnóstico laboratorial da hepatite C pelo Imunoensaio Quimioluminescente de Micropartículas (CMIA), e avaliar estes resultados com outras metodologias. Foram analisados 2535 resultados anti- VHC por CMIA para a seleção das amostras reagentes independente do valor da razão S/CO. Destas, apenas as amostras com a razão S/CO entre 1,11 e 6,99 por CMIA foram testadas por MEIA, ELISA e RT-PCR. Das 2535 amostras, 100 (3,95%) foram reagentes pela CMIA e destas, a menor freqüência foi observada em amostras com a razão S/CO entre 6,00 e 6,99. No mesmo sentido, a detecção do RNA do VHC foi crescente a partir da razão S/CO 7,00 sugerindo uma maior ocorrência de resultados falso-positivos em amostras com valor de S/CO inferior a 7,00. No período do estudo, 56 amostras apresentaram-se reagentes por CMIA com razão S/CO entre 1,11 e 6,99 e 49 (87,5%) delas foram reagentes por MEIA, das quais 25 (44,6%) também foram reagentes por ELISA. Apenas uma amostra apresentou RNA do VHC detectável por RT-PCR. Esses resultados sugerem que os resultados reagentes pelos métodos de triagem com valores próximos ao limiar de... / Hepatitis C laboratorial investigation, proposed by Ministry of Health, includes anti-HCV tests for screening and molecular methodologies for confirmation of the positive results. Some time the samples can present reagents results near to the cut off and, these results, a lot of times, are not confirmed by other methodologies. False positives results can lead blood units discard and negative psychological consequences for donors and patients. The goal of this study was establish a threshold among resulted reagents and weakly reagents in the hepatitis C laboratorial diagnosis by CMIA, and to evaluate these results with other methodologies. In this study were analyzed 2535 resulted anti-VHC by CMIA for the selection of the reagents samples independent of the S/CO obtained. The samples with S/CO between 1.11 and 6.99 by CMIA were tested by MEIA, ELISA and RT-PCR. From 2535 samples, 100 (3.95%) were reagents for CMIA and the lower frequency it was observed in samples with S/CO between 6.00 and 6.99. In the same sense, the HCV RNA detection was confirmed in samples with S/CO upper than 7.00; suggesting an occurrence of false-positive results in samples with S/CO lower to 7.00. In study period 56 samples were reagents by CMIA with S/CO between 1.11 and 6.99 and 49 (87.5%) were reagents by MEIA, which 25 (44.6%) were also reagents by ELISA. One sample presented HCV RNA detected by RTPCR. Those results suggest that the reagents results by the screening tests, with S/CO near to cut off should be analyzed with precaution and different of the reagents results with upper S/CO
2

Resultado reagente próximo ao limiar de reaticidade : uma dificuldade no diagnóstico laboratorial da hepatite C /

Ramos, Marcos Montanha. January 2010 (has links)
Resumo: O fluxograma de investigação laboratorial da hepatite C, proposto pelo Ministério da Saúde, envolve a utilização de metodologias que pesquisam anticorpos anti-VHC como testes de triagem para a infecção, sendo que os testes moleculares vêm sendo utilizados como confirmatórios mediante sorologia positiva. Neste fluxo, algumas amostras podem apresentar, nos testes de triagem, resultados reagentes próximos ao limiar de reatividade e estes resultados muitas vezes não se confirmam quando se utilizam outras metodologias. Estes resultados falso-positivos podem gerar descarte de bolsas de sangue e conseqüências psicológicas negativas para doadores e pacientes. Assim, o objetivo deste estudo foi estabelecer valores de corte entre resultados reagentes e fracamente reagentes no diagnóstico laboratorial da hepatite C pelo Imunoensaio Quimioluminescente de Micropartículas (CMIA), e avaliar estes resultados com outras metodologias. Foram analisados 2535 resultados anti- VHC por CMIA para a seleção das amostras reagentes independente do valor da razão S/CO. Destas, apenas as amostras com a razão S/CO entre 1,11 e 6,99 por CMIA foram testadas por MEIA, ELISA e RT-PCR. Das 2535 amostras, 100 (3,95%) foram reagentes pela CMIA e destas, a menor freqüência foi observada em amostras com a razão S/CO entre 6,00 e 6,99. No mesmo sentido, a detecção do RNA do VHC foi crescente a partir da razão S/CO 7,00 sugerindo uma maior ocorrência de resultados falso-positivos em amostras com valor de S/CO inferior a 7,00. No período do estudo, 56 amostras apresentaram-se reagentes por CMIA com razão S/CO entre 1,11 e 6,99 e 49 (87,5%) delas foram reagentes por MEIA, das quais 25 (44,6%) também foram reagentes por ELISA. Apenas uma amostra apresentou RNA do VHC detectável por RT-PCR. Esses resultados sugerem que os resultados reagentes pelos métodos de triagem com valores próximos ao limiar de ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Hepatitis C laboratorial investigation, proposed by Ministry of Health, includes anti-HCV tests for screening and molecular methodologies for confirmation of the positive results. Some time the samples can present reagents results near to the cut off and, these results, a lot of times, are not confirmed by other methodologies. False positives results can lead blood units discard and negative psychological consequences for donors and patients. The goal of this study was establish a threshold among resulted reagents and weakly reagents in the hepatitis C laboratorial diagnosis by CMIA, and to evaluate these results with other methodologies. In this study were analyzed 2535 resulted anti-VHC by CMIA for the selection of the reagents samples independent of the S/CO obtained. The samples with S/CO between 1.11 and 6.99 by CMIA were tested by MEIA, ELISA and RT-PCR. From 2535 samples, 100 (3.95%) were reagents for CMIA and the lower frequency it was observed in samples with S/CO between 6.00 and 6.99. In the same sense, the HCV RNA detection was confirmed in samples with S/CO upper than 7.00; suggesting an occurrence of false-positive results in samples with S/CO lower to 7.00. In study period 56 samples were reagents by CMIA with S/CO between 1.11 and 6.99 and 49 (87.5%) were reagents by MEIA, which 25 (44.6%) were also reagents by ELISA. One sample presented HCV RNA detected by RTPCR. Those results suggest that the reagents results by the screening tests, with S/CO near to cut off should be analyzed with precaution and different of the reagents results with upper S/CO / Orientador: Maria Inês de Moura Campos Pardini / Coorientador: Rejane Maria Tommasini Grotto / Banca: Giovanni Faria Silva / Banca: Neiva Sellan Lopes Gonçales / Mestre
3

Desenvolvimento e padronização de testes imunocromatográficos para diagnóstico de Escherichia coli produtora da toxina de Shiga (STEC) e Escherichia coli enterotoxigênica (ETEC). / Development and standardization of immunochromatographic test for Shiga toxin-producing Escherichia coli (STEC) and enterotoxigenic Escherichia coli (ETEC) diagnosis.

Rocha, Letícia Barboza 14 September 2012 (has links)
Escherichia enterotoxigênica e Escherichia coli produtora da toxina de Shiga (STEC) são globalmente envolvidas em doenças diarreicas e produzem a toxina termolábil e a toxina de Shiga (Stx1 e Stx2), as quais são prejudiciais ao homem. O diagnóstico é uma importante ferramenta para o correto tratamento e controle de surtos. Assim, testes imunocromatográficos (ICs) para ETEC e STEC baseados na detecção das toxinas foram desenvolvidos e padronizados utilizando anticorpos policlonais conjugados ao ouro coloidal (PAbs) e seus correspondentes anticorpos monoclonais (MAbs) anti-LT (IgG2b, 4,9 x 10-11 M), anti-Stx1 (IgG1, 2,5 x 10-10 M) e anti-Stx2 (IgG1, 6,1 x 10-10 M). Os três testes ICs detectaram até 15,6 ng/mL de LT, 15,6 ng/mL de Stx1 e 62,5 ng/mL de Stx2 e não apresentaram reatividade cruzada com os isolados não produtores da respectiva toxina alvo. Estes resultados demonstram a viabilidade e aplicabilidade dos testes ICs como ferramentas no diagnóstico de E. coli diarreiogênicas. / Shiga toxin-producing Escherichia coli (STEC) and enterotoxigenic Escherichia coli (ETEC) are worldwide involved in diarrheal diseases and produce the heat-labile (LT) and the Shiga (Stx1 and Stx2) toxins, which, cause injuries to man. The diagnosis is an important tool for the correct treatment and control of outbreaks. Thus, immunochromatographic assays (ICs) for ETEC and STEC based on toxins detection were developed and standardized using polyclonal antibodies-gold conjugated (PAbs) and their corresponding monoclonal antibodies (MAbs): anti-LT (IgG2b, 4.9 x 10-11 M), anti-Stx1 (IgG1, 2.5 x 10-10 M) and anti-Stx2 (IgG1, 6.1 x 10-10 M). The three ICs detect up to 15.6 ng/mL of LT, 15.6 ng/mL of Stx1 and 62.5 ng/mL of Stx2 and showed no cross-reaction with non-producers isolates of the respective target toxin. These results demonstrate the feasibility and applicability of the test ICs as diagnostic tools for diarrheagenic E. coli.
4

Avaliação da ação neutralizante e da reatividade de anticorpos IgA e IgG anti-rotavírus SA-11 em soro de adultos saudáveis. / Evaluation of neutralizing ability and reactivity of anti-rotavirus SA-11 IgA and IgG antibodies in serum samples from healthy adults.

Ferreira, Thalita Lopes 17 May 2011 (has links)
O rotavírus é a principal causa de diarréia em crianças em todo o mundo. Infecta também adultos, mas não há dados completos sobre a sua incidência nesse grupo nem sobre o papel de anticorpos preexistentes na proteção contra o vírus. O objetivo do trabalho foi avaliar a presença de anticorpos IgA e IgG anti-rotavírus SA-11, por ELISA, em amostras de soro de adultos saudáveis e sua ação neutralizante frente ao vírus, em ensaios de neutralização. Por Immunoblotting foi avaliado o reconhecimento de proteínas virais pelos anticorpos séricos. Observou-se que os títulos das amostras foram muito variáveis, sendo os de IgG superiores aos de IgA. Todas as amostras mostraram-se capazes de neutralizar o vírus em diferentes níveis, porém não foi possível estabelecer uma correlação com os títulos de anticorpos. Foi observado que anticorpos da classe IgG reconhecem mais proteínas virais que os da classe IgA. Este trabalho pode ser considerado mais um passo na elucidação do papel dos anticorpos séricos IgA e IgG anti-rotavírus na infecção em adultos. / Rotavirus has been considered the leading cause of diarrhea in children worldwide. The virus also infects adults but there is no conclusive data neither on the incidence of infection on this group nor on the role of pre-existing antibodies. The aim of the work was to evaluate the presence of anti-rotavirus SA-11 IgA and IgG by ELISA in serum samples of healthy adults and the serum neutralizing ability against the virus by neutralization assays. Immunoblotting was used to evaluate viral proteins recognition by serum antibodies. The antibody titers were extremely variable where IgG titers are greater than IgA ones. All samples were able to neutralize the virus in different levels but it was not possible to establish a correlation between antibody titers and neutralization ones. Immunoblotting assays revealed that IgG antibodies recognize more viral proteins than IgA did. This work can be considered a valuable step for elucidating the role of serum anti-rotavirus IgG and IgA antibodies in adults infection.
5

Padronização e avaliação de método sorológico ELISA para detecção de anticorpos IgG anti-Cryptosporidium sp / Standardization and evaluation of serological method ELISA for detection of IgG anti-Cryptosporidium sp

Casimiro, Angélica Maria 30 September 2003 (has links)
O presente trabalho teve como objetivo padronizar a técnica de ELISA para detecção de anticorpos IgG anti-Cryptosporidium sp para aplicação em estudos epidemiológicos da criptosporidiose em imunocompetentes. Para obtenção de antígeno, bezerros foram oralmente infectados. Os oocistos foram recuperados das fezes doanimal, com a utilização do gradiente de sacarose modificado, técnica de concentração onde se obteve o melhor rendimento. Para preparação do antígeno, os oocistos foram rompidos através de ciclos de congelamento/descongelamento e ultra-som. Soros controle positivo foram escolhidos entre o grupo de funcionários do laboratório de Parasitologia, pois apresentavam anticorpos anti-Cryptosporidium e devido as suas atividades no laboratório era um grupo mais exposto; soros controle negativo foram escolhidos entre aqueles com leituras de densidade óptica menores que 0,300 no ELISA para detecção de anticorpos anti-Cryptosporidium. Diferentes grupos de soros de indivíduos clinicamente normais (funcionários da parasitologia, doadores de sangue, pacientes que fizeram o Pré-Natal) ou outras infecções parasitárias (cisticercose, toxoplasmose, esquistossomose, Doença de Chagas, leishmaniose), foram avaliados para presença de anticorpos anti-Cryptosporidium. A alta freqüência foi observada para o grupo de pacientes com Doença de Chagas (66,6%) e baixa freqüência para o grupo de pacientes com esquistossomose e toxoplasmose (20,0%). A especificidade do teste ELISA para Cryptosporidium foi demonstrada com significante redução nas leituras de 0.0. observada em alguns soros após absorção dos anticorpos anti-Cryptosporidium. Além disso, no grupo de pacientes Pré-Natal 14,6%, quando comparada a alta freqüência de anticorpos anti-Cryptosporidium 52,0%, indica provável ausência de reações cruzadas entre os dois antígenos. Enfim, os resultados obtidos sugerem que a técnica de ELISA pode ser uma importante metodologia para aplicação em estudos soroepidemiológicos da criptosporidiose. / The aim of the present study was to standardize an immunoenzymatic assay, ELISA, for detection of IgG antibodies to Cryptosporidium sp for use in epidemiologic studies on cryptosporidiosis. For antigen preparation, oocysts were obtained from fecal samples of orally infected calves. A modified sucrose gradient, concentration technique was used for recovered and purification of oocysts, which were ruptured by using freezethaw cycles and ultra-sonication. Positive control sera were chosen among the Parasitology workers, who presented anti-Cryptosporidium antibodies and had been exposed to this parasite, because of their activities in the laboratory; and negative control sera were chosen among the ones with optical density (O.D.) readings lower than 0,300 at ELISA for anti- Cryptosporidium antibodies. Oifferent groups of sera from clinically normal individuais (parasitology workers, blood donors, pregnant patients) or with other parasite infection (cysticercisis, toxoplasmosis, schistosomiasis, Chagas disease, leishmaniasis) were evaluated for the presence of Cryptosporidium antibodies. The higher frequency was observed for the group of patients with Chagas disease (66.6%) and the lower frequency for the group patients with schistosomiasis and toxoplasmosis (20.0%). The specificity of the Cryptosporidium-ELISA test was demonstrated when significant reduction of the 0.0. readings was observed for some serum samples after absorption of the anti-Cryptosporidium antibodies. Also, in the group of pregnant patients, the high frequency of 52.0% for anti-Cryptosporidium antibodies when compared to the low frequency of 14.6% for anti-Toxoplasma antibodies might suggest possible absence of cross reactions between these two closely related parasite antigens. The ELISA for detection of anti-Cryptosporidium antibodies, as standardized in the present work, can constitute a good toel for epidemiological studies of cryptosporidiosis.
6

Padronização e avaliação de método sorológico ELISA para detecção de anticorpos IgG anti-Cryptosporidium sp / Standardization and evaluation of serological method ELISA for detection of IgG anti-Cryptosporidium sp

Angélica Maria Casimiro 30 September 2003 (has links)
O presente trabalho teve como objetivo padronizar a técnica de ELISA para detecção de anticorpos IgG anti-Cryptosporidium sp para aplicação em estudos epidemiológicos da criptosporidiose em imunocompetentes. Para obtenção de antígeno, bezerros foram oralmente infectados. Os oocistos foram recuperados das fezes doanimal, com a utilização do gradiente de sacarose modificado, técnica de concentração onde se obteve o melhor rendimento. Para preparação do antígeno, os oocistos foram rompidos através de ciclos de congelamento/descongelamento e ultra-som. Soros controle positivo foram escolhidos entre o grupo de funcionários do laboratório de Parasitologia, pois apresentavam anticorpos anti-Cryptosporidium e devido as suas atividades no laboratório era um grupo mais exposto; soros controle negativo foram escolhidos entre aqueles com leituras de densidade óptica menores que 0,300 no ELISA para detecção de anticorpos anti-Cryptosporidium. Diferentes grupos de soros de indivíduos clinicamente normais (funcionários da parasitologia, doadores de sangue, pacientes que fizeram o Pré-Natal) ou outras infecções parasitárias (cisticercose, toxoplasmose, esquistossomose, Doença de Chagas, leishmaniose), foram avaliados para presença de anticorpos anti-Cryptosporidium. A alta freqüência foi observada para o grupo de pacientes com Doença de Chagas (66,6%) e baixa freqüência para o grupo de pacientes com esquistossomose e toxoplasmose (20,0%). A especificidade do teste ELISA para Cryptosporidium foi demonstrada com significante redução nas leituras de 0.0. observada em alguns soros após absorção dos anticorpos anti-Cryptosporidium. Além disso, no grupo de pacientes Pré-Natal 14,6%, quando comparada a alta freqüência de anticorpos anti-Cryptosporidium 52,0%, indica provável ausência de reações cruzadas entre os dois antígenos. Enfim, os resultados obtidos sugerem que a técnica de ELISA pode ser uma importante metodologia para aplicação em estudos soroepidemiológicos da criptosporidiose. / The aim of the present study was to standardize an immunoenzymatic assay, ELISA, for detection of IgG antibodies to Cryptosporidium sp for use in epidemiologic studies on cryptosporidiosis. For antigen preparation, oocysts were obtained from fecal samples of orally infected calves. A modified sucrose gradient, concentration technique was used for recovered and purification of oocysts, which were ruptured by using freezethaw cycles and ultra-sonication. Positive control sera were chosen among the Parasitology workers, who presented anti-Cryptosporidium antibodies and had been exposed to this parasite, because of their activities in the laboratory; and negative control sera were chosen among the ones with optical density (O.D.) readings lower than 0,300 at ELISA for anti- Cryptosporidium antibodies. Oifferent groups of sera from clinically normal individuais (parasitology workers, blood donors, pregnant patients) or with other parasite infection (cysticercisis, toxoplasmosis, schistosomiasis, Chagas disease, leishmaniasis) were evaluated for the presence of Cryptosporidium antibodies. The higher frequency was observed for the group of patients with Chagas disease (66.6%) and the lower frequency for the group patients with schistosomiasis and toxoplasmosis (20.0%). The specificity of the Cryptosporidium-ELISA test was demonstrated when significant reduction of the 0.0. readings was observed for some serum samples after absorption of the anti-Cryptosporidium antibodies. Also, in the group of pregnant patients, the high frequency of 52.0% for anti-Cryptosporidium antibodies when compared to the low frequency of 14.6% for anti-Toxoplasma antibodies might suggest possible absence of cross reactions between these two closely related parasite antigens. The ELISA for detection of anti-Cryptosporidium antibodies, as standardized in the present work, can constitute a good toel for epidemiological studies of cryptosporidiosis.
7

Desenvolvimento e padronização de testes imunocromatográficos para diagnóstico de Escherichia coli produtora da toxina de Shiga (STEC) e Escherichia coli enterotoxigênica (ETEC). / Development and standardization of immunochromatographic test for Shiga toxin-producing Escherichia coli (STEC) and enterotoxigenic Escherichia coli (ETEC) diagnosis.

Letícia Barboza Rocha 14 September 2012 (has links)
Escherichia enterotoxigênica e Escherichia coli produtora da toxina de Shiga (STEC) são globalmente envolvidas em doenças diarreicas e produzem a toxina termolábil e a toxina de Shiga (Stx1 e Stx2), as quais são prejudiciais ao homem. O diagnóstico é uma importante ferramenta para o correto tratamento e controle de surtos. Assim, testes imunocromatográficos (ICs) para ETEC e STEC baseados na detecção das toxinas foram desenvolvidos e padronizados utilizando anticorpos policlonais conjugados ao ouro coloidal (PAbs) e seus correspondentes anticorpos monoclonais (MAbs) anti-LT (IgG2b, 4,9 x 10-11 M), anti-Stx1 (IgG1, 2,5 x 10-10 M) e anti-Stx2 (IgG1, 6,1 x 10-10 M). Os três testes ICs detectaram até 15,6 ng/mL de LT, 15,6 ng/mL de Stx1 e 62,5 ng/mL de Stx2 e não apresentaram reatividade cruzada com os isolados não produtores da respectiva toxina alvo. Estes resultados demonstram a viabilidade e aplicabilidade dos testes ICs como ferramentas no diagnóstico de E. coli diarreiogênicas. / Shiga toxin-producing Escherichia coli (STEC) and enterotoxigenic Escherichia coli (ETEC) are worldwide involved in diarrheal diseases and produce the heat-labile (LT) and the Shiga (Stx1 and Stx2) toxins, which, cause injuries to man. The diagnosis is an important tool for the correct treatment and control of outbreaks. Thus, immunochromatographic assays (ICs) for ETEC and STEC based on toxins detection were developed and standardized using polyclonal antibodies-gold conjugated (PAbs) and their corresponding monoclonal antibodies (MAbs): anti-LT (IgG2b, 4.9 x 10-11 M), anti-Stx1 (IgG1, 2.5 x 10-10 M) and anti-Stx2 (IgG1, 6.1 x 10-10 M). The three ICs detect up to 15.6 ng/mL of LT, 15.6 ng/mL of Stx1 and 62.5 ng/mL of Stx2 and showed no cross-reaction with non-producers isolates of the respective target toxin. These results demonstrate the feasibility and applicability of the test ICs as diagnostic tools for diarrheagenic E. coli.
8

Avaliação da ação neutralizante e da reatividade de anticorpos IgA e IgG anti-rotavírus SA-11 em soro de adultos saudáveis. / Evaluation of neutralizing ability and reactivity of anti-rotavirus SA-11 IgA and IgG antibodies in serum samples from healthy adults.

Thalita Lopes Ferreira 17 May 2011 (has links)
O rotavírus é a principal causa de diarréia em crianças em todo o mundo. Infecta também adultos, mas não há dados completos sobre a sua incidência nesse grupo nem sobre o papel de anticorpos preexistentes na proteção contra o vírus. O objetivo do trabalho foi avaliar a presença de anticorpos IgA e IgG anti-rotavírus SA-11, por ELISA, em amostras de soro de adultos saudáveis e sua ação neutralizante frente ao vírus, em ensaios de neutralização. Por Immunoblotting foi avaliado o reconhecimento de proteínas virais pelos anticorpos séricos. Observou-se que os títulos das amostras foram muito variáveis, sendo os de IgG superiores aos de IgA. Todas as amostras mostraram-se capazes de neutralizar o vírus em diferentes níveis, porém não foi possível estabelecer uma correlação com os títulos de anticorpos. Foi observado que anticorpos da classe IgG reconhecem mais proteínas virais que os da classe IgA. Este trabalho pode ser considerado mais um passo na elucidação do papel dos anticorpos séricos IgA e IgG anti-rotavírus na infecção em adultos. / Rotavirus has been considered the leading cause of diarrhea in children worldwide. The virus also infects adults but there is no conclusive data neither on the incidence of infection on this group nor on the role of pre-existing antibodies. The aim of the work was to evaluate the presence of anti-rotavirus SA-11 IgA and IgG by ELISA in serum samples of healthy adults and the serum neutralizing ability against the virus by neutralization assays. Immunoblotting was used to evaluate viral proteins recognition by serum antibodies. The antibody titers were extremely variable where IgG titers are greater than IgA ones. All samples were able to neutralize the virus in different levels but it was not possible to establish a correlation between antibody titers and neutralization ones. Immunoblotting assays revealed that IgG antibodies recognize more viral proteins than IgA did. This work can be considered a valuable step for elucidating the role of serum anti-rotavirus IgG and IgA antibodies in adults infection.
9

Avaliação da qualidade e potencial atividade adjuvante do lipídio A de Bordetella pertussis. / Quality assessment and potential adjuvant activity of Bordetella pertussis lipid A.

Santos, Fernanda Lucio dos 20 June 2011 (has links)
Atualmente várias substâncias estão sendo avaliadas quanto à sua possível atividade adjuvante, apresentando alta potência, mas também alta toxicidade, que os impede de serem introduzidos numa rotina clínica, como o lipopolissacarídio (LPS), componente da parede celular das bactérias Gram negativas. Estudos têm estimulado o desenvolvimento de derivados de LPS com propriedades potencialmente úteis, um dos exemplos mais conhecidos é o monofosforil lipídio A (MPL), desenvolvido como adjuvante para a aplicação em vacinas de uso humano. O objetivo deste estudo foi caracterizar um sub-produto do LPS de Bordetella pertussis (BpLipídioA), através do desenvolvimento e padronização de testes de controle de qualidade, visando a posterior utilização deste sub-produto como adjuvante vacinal. O conhecimento adquirido sobre o produto durante as fases de pesquisa e desenvolvimento conduziu à seleção de testes físico-químicos, biológicos e microbiológicos, bem como sua faixa de aceitação e limites de detecção. A atividade adjuvante deste produto foi realizada com a Vacina de Hepatite B Recombinante e apresentou resultados promissores. O BpLipídioA foi formulado em emulsão óleo em água, onde foi verificada a estabilidade deste composto. A utilização deste produto em emulsão ou suspensão apresentou-se possível e permite a redução da quantidade de antígeno na dose vacinal, o que aumenta a capacidade de produção das vacinas. / Currently a number of substances are being evaluated for possible adjuvant activity, with high power but also high toxicity, which prevents them from being introduced into clinical routine, such as lipopolysaccharide (LPS), cell wall component of Gram negative bacteria. The aim of this study was to characterize a byproduct of Bordetella pertussis LPS (BpLipídioA), through the development and standardization of quality control tests in order to later use this sub-product as an adjuvant vaccine. The knowledge about the product during all phases of research and development led to the selection of optimal physico-chemical, biological and microbiological tests as well as its acceptable range and detection limits. The adjuvant activity of this product was performed with the recombinant hepatitis B vaccine, which showed promissory results. Using this product in emulsion or suspension forms had to be possible to reduce the amount of antigen in the vaccine dose, which increases the installed production capacity of vaccines.
10

Avaliação da qualidade e potencial atividade adjuvante do lipídio A de Bordetella pertussis. / Quality assessment and potential adjuvant activity of Bordetella pertussis lipid A.

Fernanda Lucio dos Santos 20 June 2011 (has links)
Atualmente várias substâncias estão sendo avaliadas quanto à sua possível atividade adjuvante, apresentando alta potência, mas também alta toxicidade, que os impede de serem introduzidos numa rotina clínica, como o lipopolissacarídio (LPS), componente da parede celular das bactérias Gram negativas. Estudos têm estimulado o desenvolvimento de derivados de LPS com propriedades potencialmente úteis, um dos exemplos mais conhecidos é o monofosforil lipídio A (MPL), desenvolvido como adjuvante para a aplicação em vacinas de uso humano. O objetivo deste estudo foi caracterizar um sub-produto do LPS de Bordetella pertussis (BpLipídioA), através do desenvolvimento e padronização de testes de controle de qualidade, visando a posterior utilização deste sub-produto como adjuvante vacinal. O conhecimento adquirido sobre o produto durante as fases de pesquisa e desenvolvimento conduziu à seleção de testes físico-químicos, biológicos e microbiológicos, bem como sua faixa de aceitação e limites de detecção. A atividade adjuvante deste produto foi realizada com a Vacina de Hepatite B Recombinante e apresentou resultados promissores. O BpLipídioA foi formulado em emulsão óleo em água, onde foi verificada a estabilidade deste composto. A utilização deste produto em emulsão ou suspensão apresentou-se possível e permite a redução da quantidade de antígeno na dose vacinal, o que aumenta a capacidade de produção das vacinas. / Currently a number of substances are being evaluated for possible adjuvant activity, with high power but also high toxicity, which prevents them from being introduced into clinical routine, such as lipopolysaccharide (LPS), cell wall component of Gram negative bacteria. The aim of this study was to characterize a byproduct of Bordetella pertussis LPS (BpLipídioA), through the development and standardization of quality control tests in order to later use this sub-product as an adjuvant vaccine. The knowledge about the product during all phases of research and development led to the selection of optimal physico-chemical, biological and microbiological tests as well as its acceptable range and detection limits. The adjuvant activity of this product was performed with the recombinant hepatitis B vaccine, which showed promissory results. Using this product in emulsion or suspension forms had to be possible to reduce the amount of antigen in the vaccine dose, which increases the installed production capacity of vaccines.

Page generated in 0.0932 seconds