• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 189
  • Tagged with
  • 191
  • 191
  • 165
  • 83
  • 56
  • 53
  • 51
  • 50
  • 34
  • 31
  • 27
  • 27
  • 26
  • 24
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação das microdeformações ao redor de implantes, na utilização de pilares protéticos retos e angulados 17° e 30°, sob a influência de aplicação de cargas / Evaluation micro strain around implants in the use of straight and angled abutments 17° and 30°, under the influence of loads

Rodrigues, Vinícius Anéas [UNESP] 02 August 2017 (has links)
Submitted by vinicius anéas rodrigues null (vinicius.rodrigues@fosjc.unesp.br) on 2017-08-18T17:41:55Z No. of bitstreams: 1 tese Vinícius Anéas. Versão final.pdf: 3740548 bytes, checksum: b105ec4a9bf6381e20370d163a9e7d0c (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-08-23T19:31:12Z (GMT) No. of bitstreams: 1 rodrigues_va_dr_sjc.pdf: 3740548 bytes, checksum: b105ec4a9bf6381e20370d163a9e7d0c (MD5) / Made available in DSpace on 2017-08-23T19:31:12Z (GMT). No. of bitstreams: 1 rodrigues_va_dr_sjc.pdf: 3740548 bytes, checksum: b105ec4a9bf6381e20370d163a9e7d0c (MD5) Previous issue date: 2017-08-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo in vitro foi analisar a distribuição das microdeformações geradas ao redor de implantes de hexágono externo, sob a influência da utilização de intermediários do tipo mini pilares cônicos retos e angulados 17° e 30°, sob cargas axiais e não axiais, por meio da análise de elementos finitos e extensometria. Os modelos tridimensionais foram criados simulando três blocos de poliuretano, os quais receberam três implantes cada, um grupo perpendicular e outros dois com fixações inclinadas em 17° e 30°. Para o estudo também foram modelados os intermediários do tipo mini pilar cônico reto e angulados e uma supraestrutura metálica padronizada para ambos os grupos, os materiais foram considerados homogêneos, isotrópicos e lineares. Após a confecção, as geometrias foram exportadas em malhas para o software de análises (ANSYS 15.0, ANSYS Inc., Houston, USA), um carregamento axial de 30 kgf foi aplicado e os valores de tensão e as microdeformações foram analisados. Para análise in vitro, foram confeccionados blocos idênticos aos desenhados anteriormente. Foram colados sete extensômetros na superfície dos blocos, quatro tangenciando cada um dos implantes e três na transversal dos implantes. Coifas plásticas foram adaptadas a um enceramento padronizado e depois fundidas. A supraestrutura metálica foi parafusada com torque de 10 N.cm. Para aplicação de cargas foi utilizado um dispositivo de aplicação de cargas (DAC) com uma carga de 30 kgf. durante 10 segundos. Os dados obtidos foram submetidos aos testes ANOVA e Tukey (p< 0,05). Observou-se diferença estatística para os fatores “Angulação do implante” (P=0,000) e o fator “Ponto de aplicação de carga” (P=0,000). Os dados obtidos pela análise de elementos finitos foram apresentados como: resultados qualitativos de tensão que foram analisados seguindo o esquema de cores da escala e resultados de valores de deformação, apresentados em gráficos, onde se observou maior concentração de tensão nos implantes inclinados em 30° localizados nos pontos não axiais 3 e 5 mm, o mesmo ocorreu com os valores de deformação encontrados na superfície ao redor dos implantes. O estudo concluiu que os implantes inclinados apresentaram maiores valores de microdeformações ao redor dos implantes, sendo as aplicações de cargas não axiais nos pontos 3 e 5 mm responsáveis por produzirem aumento na magnitude. Apenas o grupo reto 0° apresentou resultados dentro do limite fisiológico em todas as configurações de aplicação de carga. / The objective of this in vitro study was to analyze microstrains distribuition generated around external hexagon implants, under the influence of intermediary prosthetic componentes as straight, 17° and 30° angled miniconical abutments, under axial and non-axial loads, by finite elements and strain-gauge analysis. The three-dimensional models were created simulating three polyurethane blocks, being installed three implants each, one perpendicular group and another two with inclined fixations at 17° and 30°. For the study were also created straight and angled miniconical abutments and a standardized metallic superstructure for both groups. The materials were considered symmetrical, isotropic and solid. After the preparation, the geometries were exported in mesh to the analysis software (ANSYS 15.0, ANSYS Inc., Houston, USA). An axial load of 30 kgf was applied and the values of main maximum stress and microstrains were analyzed. For in vitro analysis, blocks identical to those created previously were made, seven strain-gauges were placed on the surface of the block, four tangential to each of the implants and three transverse to the implants. Plastic copings were adapted to a wax pattern and then cast. The metallic superstructure was screwed with a torque of 10 N.cm. For load application, a load application device (DAC) with a load of 30 kgf was used, for 10 seconds. Data were submitted to ANOVA and Tukey tests (p <0.05). Statistical difference was observed for "Implant angulation" factors (P = 0.000) and "Load application point" factor (P = 0.000). The data obtained by the finite element analysis were presented as: qualitative results of stress that were analyzed following the color scheme of the scale and results of deformation values, presented in graphs, where it observed a higher concentration of tension in the inclined implants in 30° at the non-axial points 3 and 5 mm, the same occurred with the deformation values found on the surface around the implants. The study can conclude that the inclined implants had higher values of microdeformations around the implants, and the applications of non-axial loads at points 3 and 5 mm are responsible for producing an increase in magnitude. Only the 0° straight group presented results within the physiological limit in all load application configurations.
12

Avaliação da resistência à flexão de mini-implantes desenvolvidos para ancoragem esquelética do aparelho de Herbst - Estudo em Minipig br1 / Flexure resistance evaluation of mini implants prototypes developed for Herbst appliance anchorage Study in Minipig br1

Batista, Klaus Barretto dos Santos Lopes 23 April 2010 (has links)
Um efeito colateral indesejável do uso do aparelho de Herbst é a vestibularização excessiva dos incisivos inferiores que pode estar relacionada à retração gengival, à perda óssea marginal e à reabsorção radicular. A ancoragem esquelética do aparelho de Herbst poderia evitar estes problemas. O objetivo do presente estudo foi o de avaliar, em Minipigs br1, a resistência à flexão de protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst, comparar a resistência dos protótipos entre as duas regiões escolhidas para inserção e avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Após o cálculo do tamanho da amostra, 13 protótipos de mini-implantes foram colocados nas regiões posterior da maxila e anterior da mandíbula de três Minipigs br1, após terem sido mortos. Corpos de prova contendo os protótipos de mini-implantes inseridos em osso foram submetidos a uma força de flexão por engastamento simples utilizandose uma máquina universal de ensaios mecânicos Instron, calculando-se a média e o desvio padrão para cada região. Com o objetivo de comparar a resistência dos protótipos entre as regiões de inserção foi utilizado o Teste t de Student para duas amostras não pareadas. O teste de hipótese foi realizado para cada região para avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Para fins de comparação foram consideradas forças ortopédicas acima de 1,0 kgf. O nível de significância adotado foi P < 0,05. Os protótipos de miniimplantes apresentaram resistência à força de flexão de 13,86 kgf (DP = 2,3) para a região posterior da maxila e 20,55 kgf (DP = 5,2) para a região anterior da mandíbula. Houve diferença estatisticamente significativa entre as duas regiões com relação à força de resistência dos mini-implantes (P = 0,015), sendo que a resistência maior foi na região anterior da mandíbula. A hipótese de que os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas foi confirmada para as regiões posterior da maxila e anterior da mandíbula. Os autores concluíram que, em Minipigs br1, os protótipos de mini-implantes desenvolvidos para a ancoragem do aparelho de Herbst foram capazes de resistir a forças entre 13,86 e 20,55 kgf, sendo estatisticamente mais resistentes na região anterior da mandíbula e capazes de suportar forças ortopédicas. / An undesirable tooth movement resulting from use of the Herbst appliance is the excessive proclination of the anterior mandibular teeth, which is commonly associated with gingival recession, marginal bone loss, and root resorption. Skeletal anchorage of the Herbst appliance could prevent these problems. The present study was designed to evaluate, in Minipigs br1, the flexure resistance of prototype miniimplants developed for Herbst appliance anchorage, to compare the prototype resistance between the regions in which the mini-implants were placed, and to test the hypothesis that these mini-implant prototypes can withstand orthopedic forces. After calculation of sample size, 13 mini-implant prototypes (2 mm in diameter x 10 mm long) were inserted in the posterior region of the maxilla and the anterior region of the mandible, in three recently killed minipigs. The specimens were submitted to a single cantilever flexure test using an Instron testing machine. Mean and standard deviation were calculated for each region. To compare the resistance of the prototypes between the sites of mini-implant insertion, a 2-Sample Students t test was calculated. The test was carried out individually for each region, to evaluate if the prototype mini-implants developed for Herbst appliance anchorage could withstand orthopedic forces. Orthopedic forces above 1.0 kgf were considered. The level of significance was set at P < 0.05. The prototype mini-implant showed a flexure strength of 13.86 kgf (SD = 2.3) for the posterior region of the maxilla, and 20.55 kgf (SD = 5.2) for the anterior region of the mandible. A significant statistically difference was found in the resistance of the prototypes between the two regions (P = 0.015). The hypothesis that the prototype mini-implants can withstand orthopedic forces was confirmed. The authors concluded that, in Minipigs br1, the prototype mini-implants developed for Herbst appliance anchorage could resist forces from 13.86 to 20.55 kgf, were statistically more resistant in the anterior region of the mandible, and were capable of withstanding orthopedic forces.
13

Avaliação histológica e histomorfométrica da energia superficial e molhabilidade em implantes de titânio grau IV e grau V: estudo experimental em coelhos / Histologic and histomorphometric evaluation of surface energy and wettability in dental implants of titanium grade IV and V: experimental study in rabbits

Miranda, Aline Baia 15 August 2016 (has links)
O presente estudo teve como objetivo avaliar a resposta biológica ao redor de implantes de titânio grau IV (titânio comercialmente puro) e grau V (Ti6Al4V), com diferentes tipos de tratamentos de superfície através da análise do contato ossoimplante (bone implant contact - BIC) e da área de neoformação óssea com e sem fluorocromo (bone area BA e BAfluo) das 3 primeiras roscas em contato ósseo de cada implante. Para isso, utilizou-se um total de 90 implantes Cone Morse de titânio grau IV (Drive 45 implantes) e titânio grau V (Facility 45 implantes), com dimensões de 3.5x8mm e 2.9x7mm, respectivamente. Estes dois tipos de implantes foram avaliados em três tratamentos de superfícies diferentes: a) superfície com jateamento com partículas abrasivas seguido de tratamento ácido - NeoPoros (NP) - em embalagem seca (Grupo Controle); b) superfície jateada seguido de tratamento ácido e energia de superfície, armazenado em líquido (ESm); c) superfície jateada seguido de tratamento ácido com energia de superfície e embalado a seco (ESs); totalizando 6 grupos, distribuídos em 15 coelhos New Zealand, em cada um foram instalados 6 implantes, sendo 3 em cada tíbia. Após 15 dias de osseointegração, os coelhos passaram por eutanásia e as tíbias seccionadas, fixadas e incluídas para a avaliação histológica e histomorfométrica. Mensurações no analisador de imagens ImageJ foram realizadas e a análise dos dados estatísticos, de todos os grupos foram avaliados através da análise de variância a dois critérios e do teste de Tukey para comparações múltiplas grupo a grupo, adotando o nível de significância de 5% (p<0,05). Os resultados mostraram que não houve diferença estatisticamente significante entre os dois tipos de titânio, porém houve diferença estatisticamente significante entre os tipos de superfície em relação ao BIC, BA e BAfluo; também, não houve interação entre titânio e superfície. Na análise do contato osso-implante (BIC) a superfície ESm teve melhor desempenho em relação ao NP, que por sua vez foi semelhante ao ESs. Quanto à área óssea (BA), a superfície NP teve menor desempenho em relação à ESs, este obteve semelhante desempenho a ESm. Quanto a área ósseo neoformada com presença de fluorocromo (BAfluo), NP teve menor desempenho em relação ao ESs, o qual obteve semelhante comportamento a ESm. Com isso, concluiu-se que implantes de titânio de gau IV e grau V obtiveram respostas biológicas equivalentes, enquanto que a energia de superfície com a molhabilidade podem ser consideradas como vantagem, uma vez que otimizam o processo de osseointegração. / This study aimed to evaluate the biological response around grade IV (commercially pure titanium) and grade V (Ti6Al4V) titanium implants with different types of surface treatments by analyzing bone-implant contact (BIC) and the bone formation area with and without fluorochrome (BA and BAfluo) of the 3 first threads on bone contact of each implant. To this end, this study used 90 Morse Taper grade IV (Drive - 45 implants) and grade V (Facility - 45 implants) titanium implants, measuring 3.5x8mm and 2.9x7mm, respectively. Both types of implants were evaluated in three different surface treatments: a) blasted/acid-etched implant surface - NeoPoros (NP) - dry pack (control group); b) blasted/acid-etched implant surface and surface energy, stored in liquid (ESm); c) blasted/acid-etched implant surface with surface energy and dry packed (ESs); totalizing 6 groups, distributed in 15 New Zealand rabbits. Six implants were placed in each rabbit, 3 in each tibia. After 15 days of osseointegration, the rabbits were euthanized and the tibias sectioned, fixed and embedded for histologic and histomorphometric evaluation. Measurements were carried out using the image analysis program ImageJ and the assessment of statistical data concerning all groups was done through the two-way analysis of variance and the Tukey test for multiple comparisons group to group, adopting the significance level of 5% ( p <0.05). The results showed no statistically significant difference between the types of titanium used. However, there were statistically significant differences between the types of surface in relation to the BIC, BA and BAfluo. In addition, there was no interaction between titanium and the surface. Concerning the analysis of bone-implant contact (BIC), the ESm surface had better performance compared to the NP, which, in turn, was similar to the ESs. As for bone area (BA), the NP surface had lower performance in relation to the ESs surface, as the latter had a similar performance to the ESm surface. Concerning the newly formed bone area with presence of fluorochrome (BAfluo), the NP had lower performance if compared to the ESs, which behaved similarly to that of the ESm surface. Thus, this study concluded that grade IV and grade V titanium implants showed equivalent biological responses, while the surface energy, together with its wettability, can be considered an advantage, enhancing the osseointegration process.
14

Estudo de coorte prospectivo do padrão ósseo alveolar em mulheres eutróficas e obesas antes e após a cirurgia bariátrica / Prospective cohort study of alveolar bone pattern in eutrophic and obese women before and after bariatric surgery

Cabral, Jefry Alberto Vargas 20 February 2017 (has links)
O tecido adiposo pode regular o metabolismo ósseo e estar envolvido na fisiopatologia da osteoporose, sendo este fator determinante no sucesso de tratamentos reabilitadores com implantes dentários osseointegrados. O presente estudo de coorte prospectivo teve como objetivo verificar o padrão ósseo alveolar por meio de índices radiomorfométricos da radiografia panorâmica e medidas lineares realizadas em radiografias periapicais, em pacientes eutróficas e obesas mórbidas antes e após a cirurgia bariátrica. A amostra foi constituída por 31 mulheres com idade de 20 a 35 anos, sendo divididas em 2 grupos: Grupo Experimental (GE-Obesas de Grau III, IMC >40 Kg/m2) e Grupo Controle (GC- Eutróficas, IMC 18,5 a 24,99 Kg/m2). Foram avaliadas 20 eutróficas e 11 obesas mórbidas no pré e pós-cirurgia bariátrica (6 meses). Índices radiomorfométricos e de placa dentária foram avaliados nos tempos T0 (baseline) e T1 (6 meses). Na análise radiográfica foram avaliados o padrão trabecular através da escada visual de Lindh e a perda óssea por meio do cálculo da distância da junção cemento-esmalte à crista óssea, em radiografias periapicais. Já as radiografias panorâmicas para mensurar Índice da Cortical Mandibular (ICM), Índice Mentoniano (IM) e Índice Panorâmico Mandibular (IPM), além do índice de Placa de Turesky. Houve perda óssea significativa em T1 nas pacientes submetidas à cirurgia bariátrica, quando comparada com as eutróficas (p<0,05). O padrão trabecular tornou-se mais esparso após a cirurgia apresentando uma diferença visual. No índice de placa foi observada uma ligeira melhora após a cirurgia e os eutroficos mantiveram valores similares ao longo do tempo. Pode-se concluir que pacientes obesas apresentam maior perda óssea, a qual piora após a cirurgia bariátrica, quando comparada com o de pacientes eutróficas. O mesmo acontecendo com o trabeculado ósseo que se torna mais esparso após a cirurgia bariátrica. / Adipose tissue can regulate bone metabolism and be involved in the pathophysiology of osteoporosis, being this determinant factor in the success of rehabilitative treatments with osseointegrated dental implants. The present prospective cohort study aimed to verify the alveolar bone pattern through radiomorphometric indices of panoramic radiography and linear measurements performed in periapical radiographs in eutrophic and morbidly obese patients before and after bariatric surgery. The sample consisted of 31 women aged 20-35 years old, divided into 2 groups: Experimental Group (GE-Obesas de Grade III, BMI> 40 Kg / m2) and Control Group (GC-Eutrophic, BMI 18.5 To 24.99 kg / m2). 20 eutrophic and 11 obese morbidities were evaluated in the pre and postoperative bariatric surgery (6 months). Radiomorphometric and plaque indices were evaluated at T0 (baseline) and T1 (6 months) times. In the radiographic analysis the trabecular pattern through the Lindh visual ladder and the bone loss were evaluated by calculating the distance from the cemento-enamel junction to the bone crest in periapical radiographs. Panoramic radiographs were used to measure the Mandibular Cortical Index (ICM), Mentonian Index (IM) and Panoramic Mandibular Index (MPI), in addition to the Turesky Plate index. There was a significant loss of bone in T1 in patients submitted to bariatric surgery, when compared to eutrophic patients (p <0.05). The trabecular pattern became more sparse after surgery with a visual difference. The plate index showed a slight improvement after surgery and the eutrophic maintained similar values over time. It can be concluded that obese patients present greater bone loss, which worsens after bariatric surgery, when compared to that of eutrophic patients. The same happens with the trabecular bone that becomes more sparse after bariatric surgery.
15

Avaliação da estabilidade de implantes com diferentes tratamentos de superfície: ensaio clínico randomizado / Evaluation of implants stability with different surface treatments: randomized controlled clinical trial

Moreira, Érico Castaldin Fraga 13 August 2013 (has links)
Os tratamentos de superfície dos implantes, por meio de adição ou subtração, tem permitido sua ativação de forma precoce com relação ao preconizado, inicialmente, por Branemark. Este trabalho constituiu-se de ensaio clínico, randomizado, controlado, duplo cego e de grupos paralelos. Avaliou-se, clinicamente, a estabilidade no pós-cirúrgico imediato e a sua evolução no período de oito semanas em implantes de mesma macrogeometria, diâmetro e comprimento em dois grupos: implantes de superfície tratada por duplo ataque ácido (grupo controle) e implantes de superfície anodizada (grupo teste). Os grupos foram avaliados quanto ao: torque de inserção, estabilidade inicial pela análise de frequência de ressonância, sua evolução no período de oito semanas e a influência do tipo ósseo na estabilidade dos grupos estudados. Foram colocados 59 implantes na maxila. Os sítios para a colocação dos implantes foram divididos aleatoriamente. Ao final do procedimento cirúrgico, foi aferido o torque de inserção e a estabilidade dos implantes por meio de análise de frequência de ressonância, com o aparelho Osstell. Esta também foi mensurada nas oito semanas seguintes à instalação. Sete implantes não atingiram o critério de inclusão para a obtenção do quociente de estabilidade do implante (ISQ). 3 do grupo controle e 2 do grupo teste apresentaram torque de inserção inferior a 20N e um de cada grupo necessitou de regeneração tecidual guiada impedindo a aferição do ISQ. Do total, 4 implantes apresentaram rotação dentro das oito semanas, o que levou à sua remoção. O grupo controle obteve torque de inserção de 45,5±18,5 Ncm e ISQ inicial de 71,6±5,5 e o grupo teste torque de inserção de 44,8±20,9 Ncm e ISQ inicial de 69,8±9,8, sendo estatisticamente similares. Essa semelhança no comportamento entre os grupos manteve-se durante todo o período de avaliação. O grupo controle atingiu, ao final de oito semanas, o ISQ médio de 70,8±6,7 e o teste de 69,7±6,0. Os resultados estatísticos demonstraram que não houve interação entre os fatores grupo e semana, entretanto, o fator semana indicou que houve variação estatística significante ao longo do tempo (p=0,003), independente do tipo de implante utilizado, com o ISQ semana 1, menor estatisticamente que todos os demais. O torque de inserção e o valor da análise de frequência de ressonância mostraram uma relação linear significante entre ambos (r=0,409, p<0,003). A média do ISQ pós-cirúrgico imediato e do torque de inserção para osso tipo II foram estatisticamente maiores que as médias para o osso tipo IV. Pode-se, assim, concluir que os grupos foram similares no que se refere a estabilidade inicial aferida tanto pelo torque de inserção quanto pela análise de frequência de ressonância, equivalência esta presente durante todo o período de oito semanas avaliado. O estudo mostrou também que a variação do tipo ósseo poderia levar a alterações na estabilidade dos implantes. / Surface treatments has allowed the loading of the implants at an early period with respect to it was recommended initially by Branemark. This study consisted of a blinded random clinical trial. It were evaluated, clinically, the stability immediate after the surgery and its evolution over the period of eight weeks in implants with the same geometry, diameter and length in two groups: dual acid etching surface (group control) and anodized surface (test group). The groups were evaluated for: insertion torque, initial stability, its evolution in the eight week period and the influence of bone type on the stability of the groups studied. 59 implants were placed in the maxilla. The sites for placement of the implants were randomly divided. At the end of the surgical procedure, it were measured insertion torque and implant stability using resonance frequency analysis (RFA), with Osstell. RFA was also measured in the eight weeks following the implant installation. Seven implants did not meet the inclusion criteria for obtaining the Implant Stability Quotient (ISQ), 3 implants, in the control group, and 2, in the test group, showed insertion torque lower than 20 Ncm and one in each group needed guided tissue regeneration which did not allow ISQ measurement. Of the total, 4 implants showed spin within eight weeks, and they were removed. The control group had insertion torque of 45.5 ± 18.5 Ncm and initial ISQ of 71.6 ± 5.5 and the test group had insertion torque of 44.8 Ncm ± 20.9 and initial ISQ of 69.8 ± 9.8, which was statistically similar. This similarity in the behavior between groups was maintained throughout the whole period of evaluation. The control group reached, in the end of eight weeks, the mean ISQ of 70.8 ± 6.7 and test reached 69.7 ± 6.0. The statistical analysis demonstrated that there was no interaction between the factors: \"group\" and \"week\"; however, the factor \"week\" indicated that there was statistically significant variation over time (p = 0.003). Independent of the type of implant used, the ISQ at first week was statistically lower than everyone else. The insertion torque and the resonance frequency analysis showed a significant linear relationship between them (r = 0.409, p <0.003). The mean ISQ, immediately after surgery, and insertion torque for bone type II were significantly higher than the averages for the bone type IV. We can conclude that the groups were similar in regard to stability measured, by the insertion torque and the initial resonance frequency analysis. Equivalence that is present throughout the eight week period of evaluation. The study also showed that depending on variation in the type of bone could lead variations in the implant stability.
16

Resistência à remoção por tração de coroas NiCr cimentadas sobre munhões usinados em liga de titânio, irradiados ou não por LASER / Tensile strenght of NiCr crowns cemented upon usinated titanium alloy abutments, LASER irradiated or not

Toledo, Fabiane Lopes 24 May 2007 (has links)
No presente trabalho, usando ensaios de remoção por tração, o objetivo foi avaliar a eficiência de 4 agentes (fosfato de zinco S. S.White, ionômero de vidro Ketac Cem Easymix, resina composta RelayX Luting 2 e resina acrílica especial Panavia 21 TC) usados para fixar coroas totais de NiCr a munhões tronco-cônicos, usinados em liga de Ti-6Al-4V. Dentre os cinqüenta munhões utilizados, 40 permaneceram com sua superfície original altamente lisa (como vieram de fábrica) e foram distribuídos em grupos de 10, para cada agente cimentante; no grupo dos 10 restantes existiu uma modificação por irradiação com LASER e cimentação apenas com fosfato. Os ensaios mecânicos foram realizados em uma máquina universal MTS 810, na velocidade de 0,5 mm/min. A respectiva Análise de Variância (ANOVA) apontou existir diferença significante entre os grupos e o teste de Tukey (p<0,05) também mostrou diferenças significantes entre eles, exceto nas comparações original/fosfato versus original/RelayX e original/fosfato versus original/KetcCem. Para os munhões não-irradiados, o melhor desempenho foi apresentado pela resina Panavia 21 (1.127,996 N); a resina composta RelyX (478,197 N) mostrou comportamento similar apenas ao do fosfato (430,662 N), o qual apresentou desempenho semelhante ao ionômero de vidro KetacCem (227,705 N). A modificação da superfície do munhão fez com que a magnitude da resistência à tração das coroas cimentadas com fosfato aumentasse para 1.514,872 N. / By means of tensile essays, NiCr total crowns were removed from usinated tronco-conical abutments composed by an Ti-6Al-4V alloy; the performance of 4 cementig agents (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelayX Luting 2 composite resin and Panavia 21 TC special acrylic resin) was evaluated. Among a total of 50 abutments, 40 were used with it surface presenting high smoothness (as they come from manufacturer) and distributed in groups of 10 elements, each group for each cementing agent; the other 10 abutments had had its surfaces modified by LASER and were used only with phosphate. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukey´s test (p<0.05) also detected significant differences, except at comparisons of original/phosphate versus original/ RelayX and original/phosphate versus original/ KetacCem. To non-irradiated abutments, the better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of KetacCem (227.705 N). The referred LASER irradiation promoted an increased resistance to the phosfate, which reached 1,514.872 N.
17

Análise da precisão de uma nova moldeira para implantes dentários / Accuracy of a new impression tray for dental implants

Marotti, Juliana 12 November 2012 (has links)
Considerando as dificuldades envolvidas no processo de moldagem com a moldeira aberta convencional, objetivou-se neste estudo avaliar a precisão da moldagem de transferência de implantes dentais utilizando uma nova moldeira, desenvolvida com o objetivo de facilitar a técnica de moldagem. Foi confeccionado um modelo de referência de uma mandíbula edentada e instalados quatro implantes nas regiões dos elementos 44, 42, 32 e 34, denominados implantes 1, 2, 3 e 4, respectivamente. Sobre este modelo confeccionou-se uma barra de Cr-Co, para análise do desajuste. Foram realizadas 10 moldagens com silicona de adição para cada grupo (controle, moldeira aberta convencional) e teste (nova moldeira, Miratray Implant!) do modelo de referência, e após obtenção do modelo em gesso, a barra metálica foi parafusada somente no implante 1, e medida a fenda gerada na face vestibular dos implantes 3 e 4 por meio de microscópio óptico com aumento de 16x. As imagens foram analisadas por um único operador no tempo inicial e após uma semana por meio do software ImageLab. Os grupos foram comparados pelo teste de Mann-Whitney e Wilcoxon, com nível de significância estabelecido em 5%, pelo software estatístico SPSS. Os resultados mostraram diferença estatística (p = 0,04) ao comparar a média da primeira repetição do implante 3 (teste x controle); ao comparar a primeira repetição com a segunda para o implante 4 apenas no grupo controle; e na comparação dos valores máximos entre os implantes 3 e 4 do grupo controle. Em relação aos valores máximos do implante 3, obteve-se a média de 116 ± 45 m para o grupo controle, e 158 ±17 m para o grupo teste. Já para o implante 4, obteve-se a média de 106 ± 46 m para o grupo controle e 156 ± 22 m para o grupo teste. Considerando que o máximo desajuste permitido seria de 150 m, apenas o grupo controle teria um desajuste considerado aceitável clinicamente para o implante 3, entretanto sem diferença estatística para o implante 4. Como os valores dos grupos teste e controle foram muito próximos, dentro das limitações deste estudo pode-se concluir que a nova moldeira promove uma precisão do sistema barra/implante muito próxima à moldeira aberta convencional. / Considering the difficulties involved in the impression taking process when using the conventional open impression tray, the aim of this study was to evaluate the accuracy of transfer impression of dental implants using a new impression tray developed with the object of facilitating the impression-taking technique. A reference model of an edentulous mandible was fabricated, and four implants were placed in the regions of teeth 44, 42, 32 and 34, denominated implants 1, 2, 3 and 4, respectively. To analyze misfit, a Cr-Co bar was fabricated on this model. Ten impressions were taken with polyvinyl siloxane for each group (control, conventional open impression tray) and test (new impression tray, Miratray Implant!) from the reference model. After obtaining the plaster model, a metal bar was screw-retained on implant 1 only, and the gap generated at the vestibular face of implants 3 and 4 was measured by optical microcopy at 16x magnification. A single operator analyzed the images at the initial time and after one week, using ImageLab software. Groups were compared by the Mann-Whitney and Wilcoxon tests, with level of significance established at 5%, using statistical SPSS software. The results showed statistical difference (p = 0.04) when the mean of the first repetition of implant 3 (test x control) was compared; when the first repetition was compared with the second, for implant 4 only in control group; and in comparison of the maximum values between implants 3 and 4 of control group. As regards maximum values of implant 3, a mean of 116 ± 45 m was obtained for control group, and 158 ±17 m for test group. Whereas, for implant 4, a mean of 106 ± 46 m was obtained for control group and 156 ± 22 m for test group. Considering that the maximum misfit permitted would be 150 m, only control group would have a misfit considered clinically acceptable for implant 3, however, without statistical difference for implant 4. As the test and control group values were very close, within the limitations of this study, it could be concluded that the new impression tray promotes bar/implant system accuracy very close to that of the conventional open impression tray.
18

Influência do método de osteotomia para preparação do leito na reparação óssea ao redor de implantes de titânio: comparação histológica entre instrumento rotatório e ultrassom cirúrgico piezoelétrico / Piezosurgery influence in bone healing around titanium dental implants: histological study in rats

Ferreira, Marcelo Sirolli 19 February 2014 (has links)
O objetivo deste estudo foi avaliar histomorfometricamente a influência da piezocirurgia (PZ) sobre a reparação óssea ao redor de implantes de titânio. Foram utilizados 15 ratos machos Wistar, com aproximadamente 300g, nos quais em uma das patas o leito para instalação de um implante de titânio foi realizado com um motor rotatório convencional (Grupo Controle) e na outra com ultrassom cirúrgico piezoelétrico (Grupo Piezo). Após 30 dias, os animais foram sacrificados para obtenção do material para análise histológica. Foram avaliados os seguintes parâmetros histomorfométricos (em porcentagem), separadamente, para a região cortical e medular: a proporção de tecido mineralizado (PTM) na região adjacente ao implante (500m adjacentes); área de tecido mineralizado (AO) dentro dos limites das roscas do implante; e a extensão de tecido ósseo em contato direto (CD) com a superfície do implante. Os resultados deste estudo mostraram que não foram observadas diferenças para CD na região medular (p>0,05) e para PTM na região cortical (p>0,05). Por outro lado, um maior preenchimento das roscas foi observado quando utilizou-se a PZ tanto na região cortical (71,50 + 6,91 e 78,28 + 4,38; média + dp para os grupos Controle e Piezo; respectivamente p<0,05) quanto na região medular (9,62 + 4,06 e 19,94 + 14,18; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Resultados semelhantes foram observados para o parâmetro PTM na região medular (9,35 + 5,54 e 18,72 + 13,21; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Já a técnica convencional foi superior à PZ em relação a CD na região cortical (80,42 + 10,88 e 70,25 + 16,93; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Dentro dos limites do presente estudo, pode-se concluir que a piezocirurgia apresenta-se como uma alternativa viável no preparo de leito para instalação de implantes de titânio. / The aim of this study was to investigate the influence of two techniques of dental implant site preparation on bone healing around titanium dental implants. Fifteen male Wistar rats (+ 300g) were used in the study. In each rat tibiae was randomly assigned to receive the implant site preparation with a conventional drilling technique (Control) or with piezoelectric device (Piezo). After thirty days the animals were sacrificed and then the following histomorphometric parameters were evaluated (in percentage) separately to cortical and cancellous regions: Proportion of mineralized tissue (PMT) adjacent to implant threads (500um adjacent); bone area within the threads (BA); and bone-implant contact (BIC). The results demonstrated that there were no differences between the two groups for cancellous BIC (p>0.05) and cortical PTM (p>0.05). Meanwhile, a higher percentage of BA was observed in PIEZO group in the cortical (71,50 + 6,91 and 78,28 + 4,38; mean + stdev for groups Control and Piezo; respectively p<0.05) and cancellous regions (9,62 + 4,06 and 19,94 + 14,18; mean + stdev for groups Control and Piezo; respectively p<0.05). The piezosurgery also showed higher PTM values in the cancellous zone (9,35 + 5,54 and 18,72 + 13,21; mean + stdev for groups Control and Piezo; respectively p<0.05). However, Control presented better results for BIC in cortical region (80,42 + 10,88 and 70,25 + 16,93; mean + stdev for groups CTRL and PIEZO; respectively p<0.05). Within the limits of the present study, it can be concluded that piezosurgery is a feasible alternative in implant site preparation.
19

Estudo in vitro de um material para selamento da interface implante-intermediário do tipo minipilar cônico em implantes de hexágono externo, hexágono interno e cone morse / In vitro sealing of a material of implant-abutment interface of mini conical pillar: inimplant external hexagon, internal hexagon and Morse taper

Nascimento, Mônica Lôbo do 08 May 2012 (has links)
A micro infiltração de fluidos bucais e bactérias na interface implante e o intermediário são discutidos na literatura através de várias pesquisas pontuando e determinando que o espaço existente entre os componentes e as conexões dos implantes, chamados de GAP, que parece ser a fonte da infiltração de microorganismos, quer a partir de meio externo para meio interno ou vice versa, resultando em reações inflamatórias nos tecidos periodontais. Portanto, este estudo teve como objetivo analisar um método para evitar e ou pelo menos diminuir micro infiltração na interface implante-intermediário utilizando um material de vedação chamado Loctite® 222 (Henkel Ltda). Este é um material monocomponente, anaeróbico, tixotrópico, de baixa resistência à desmontagem sendo utilizado industrialmente para ajustar os parafusos. Os implantes testados neste estudo foram de três diferentes sistemas de conexão protética: hexágono externo (n = 10), hexágono interno (n = 10) e cone morse (n = 10) e estes foram todos fabricados pela mesma empresa (SIN - Sistema de Implantes). Inicialmente, esses implantes foram utilizados como grupo controle, não recebendo a aplicação do selante na área de conexão. Mini intermediários cônicos foram sentados sobre os corpos dos implantes e o torque foi aplicado seguindo recomendação dos fabricantes. Cada implante foi imerso em um criotubo de 2ml contendo 1,5 ml de BHI estéril. Todos foram inoculados com 250l de Enterecoccus faecalis (ATCC - 29212) no interior do criotubo. Os implantes foram limpos, esterilizados e divididos em 3 grupos testes. Uma fina camada do selante foi aplicada com microbrush sobre a área de conexão antes de encaixar os pilares e logo foi aplicado o torque conforme as recomendações do fabricante. Períodos de avaliação, de 7, 14, 21, 35, 49 e 63 dias foram realizados para analisar a presença de micro infiltração do meio interno dos implantes, seguindo regulamentações específicas no fluxo laminar. Os resultados mostraram a eficácia do material selante quando se compara o grupo controle com os grupos testes. Uma eficácia de 100% foi encontrada para todos os sistemas de implantes estudados, o hexágono externo, hexágono interno e cone morse. / Microbial and fluidic leakage in the implant-abutment interface are shown in literature through a variety of studies, accusing the space that exists between the components of the implant, called \"GAP\", which seems to be the source of the microorganism infiltration, either from the external to the internal environment or the inverse, resulting in inflammatory reactions of the periodontal tissues. Therefore, this study aimed to analyze a method to avoid or at least reduce microleakage at the implant-abutment interface by using a sealing material named Loctite ® 222 (Henkel Ltda). This is a single component, anaerobic, thixotropic, lowstrength threadlocker material industrially used to adjust screws. The implants tested in this study were of three different implant-abutment systems: external hexagon (n=10), internal hexagon (n=10) and morse cone connection (n=10) and these were all manufactured by the same company (SIN - Implant System). Initially, these implants were used as the control group, not receiving the sealant application at the connection area. Mini conical abutments were seated over the implant bodies and torque-tightened to 20 Ncm. Each implant was immersed in a 2ml cryotube containing 1.5 ml of sterile BHI. All implants were inoculated with 250l of Enterecoccus faecalis (ATCC - 29212) inside the cryotube. The same implants were then cleaned, sterilized and divided into 3 test groups. A thin layer of the sealant was applied on the connection area before seating the abutments and proceeding as described before. Evaluation periods of 7, 14, 21, 35, 49 and 63 days were performed to analyze the presence of external contamination of the internal environment, following specific regulations in laminar flow. The results showed the effectiveness of the sealant material when comparing the control group to the test groups. An efficacy of 100% was found for all implant systems studied, the external hexagon, internal hexagon and Morse cone connection.
20

Avaliação do direcionamento e angulação das fibras de colágeno ao redor de implantes do tipo cone morse e hexágono externo sob luz polarizada em cães / Histological evaluation of collagen fibers orientation and angulation around external hexagon and cone morse implants under a polarized light

Castro, Daniel Sartorelli Marques de 08 February 2012 (has links)
Foram avaliados o direcionamento e as características das fibras colágenas ao redor de dois diferentes tipos de implantes, cone Morse e hexágono externo. Este estudo foi aprovado pelo comitê de ética no ensino e pesquisa em animais da Faculdade de Odontologia de Bauru, recebendo o protocolo de número 03/2008. Foram instalados 42 implantes em sete cães, sendo 14 do tipo hexágono externo (Osseotite - 3i, USA ) e 28 do tipo Cone Morse ( Titamax EX CM Neodent, Brazil ), todos receberam componentes protéticos, seguindo o protocolo de carga imediata, após 4 meses, todos os animais foram sacrificados e as amostras coletadas e processadas pelo sistema Exakt. Para a avaliação do direcionamento das fibras colágenas foram avaliadas 18 amostras, que foram observadas em um microscópio óptico, sobre a influência de luz polarizada. No grupo hexágono externo foram encontradas fibras colágenas oriundas do epitélio alveolar correndo paralelamente a superfície do implante e seu componente protético, em algumas amostras se uniam a outros grupos de fibras e se direcionavam a região das roscas do implante. Foram encontradas fibras que poderiam ser classificadas como perpendiculares em apenas 3 amostras, localizadas abaixo da plataforma protética, não foram observados sinais de inserção das fibras nas regiões do cilindro de proteção ou componente rotético, apenas abaixo da plataforma do implante. Ao redor das amostras do grupo cone morse, foram encontrados grupos de fibras que corriam paralelamente a superfície do componente protético, em direção a plataforma do implante. Em 6 amostras deste grupo, foram observadas fibras que foram classificadas como obliquas ou perpendiculares, distribuídas lateralmente a região mais profunda do componente protético, apresentando sinais de inserção, não foram observadas fibras se inserindo diretamente ao implante. Quando observamos os valores correspondentes aos dois grupos avaliados, podemos observar a maior predominância de fibras classificadas como paralelas-obliquas no grupo I, com 16 amostras, duas outras amostras deste grupo poderiam ser classificadas como obliquas. No grupo III, a maior predominância das amostras se encontram classificadas como obliquas, com 11 amostras, outras 5 amostras deste grupo podem ser classificadas como obliquasperpendiculares, o grupo Cone Morse apresentou um valor de 70,20 graus para a face vestibular e 54,73 graus para a face lingual, o grupo Hexágono externo, apresentaram valores médios de 19,88 graus para a face vestibular e 21,92 graus para a face lingual. Baseado na metodologia empregada e nos resultados encontrados, podemos concluir que o tipo de interface protética parece influenciar o comportamento do tecido conjuntivo e que a maior estabilidade fornecida pelos implantes que utilizam interface cônica, parece permitir a inserção de fibras de colágeno diretamente ao componente protético, proporcionando uma melhor estabilidade tecidual e proteção aos implantes. / This study aims to evaluate the presence and orientation of the collagen fibers around two different implant types. 42 implants were installed in seven dogs, 14 external hexagon (Osseotite - 3i, USA) and 28 cone morse (CM Titamax EX - Neodent, Brazil), all received prosthetic components, following the immediate loading protocol. After 4 months of healing, the animals were sacrificed and samples were collected and processed for histological evaluation by means of Exakt processing system. To assess the direction of collagen fibers, 10 samples from each group were evaluated in an optical microscope, under the incidence of polarized light. In the external hexagon group were found collagen fibers derived from alveolar epithelium running parallel to the implant and his prosthetic component, in some samples these fibers joined with other groups and drove to the implant threads. Were found Fibers that could be classified as perpendicular in only three samples, located below the implant platform, no insertion signals were observed on cylinder of protection or prosthetic component, just below the implant platform. Around the morse taper group samples were found groups of fibers that ran parallel to the surface of the prosthetic component toward the implant platform. In six samples of this group, were observed fibers that were classified as oblique or perpendicular, laterally distributed to the deepest region of the prosthetic component, showing signs of insertion, were no observed fibers inserting directly to the implant surface. When we look at the values corresponding to both groups, we can observe the predominance of fibers classified as parallel-oblique on group I, with 16 samples, two other samples of this group could be classified as oblique. On group III, the highest prevalence of the samples are classified as oblique, with 11 samples, five other samples of this group can be classified as oblique-perpendicular, the morse taper group showed a mean value of 70.20 degrees to the buccal and 54,73 degrees to the lingual, external hexagon group presented mean values of 19.88 degrees to Buccal and 21.92 degrees to lingual. Based on the methodology used and results, we conclude that the type of prosthetic interface appears to influence the behavior of the tissue and that the stability provided by the implants using conical interface, seems to allow the insertion of collagen fibers directly to the prosthetic component, providing better tissue stability and protection to the implants.

Page generated in 0.5071 seconds