• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • Tagged with
  • 45
  • 45
  • 13
  • 12
  • 10
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Implante dérmico acelular sintético no subcutâneo e na superfície da pele de cobaias

Natsuaki, Kryscia Leiko [UNESP] 16 July 2015 (has links) (PDF)
Made available in DSpace on 2016-08-12T18:48:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-16. Added 1 bitstream(s) on 2016-08-12T18:50:59Z : No. of bitstreams: 1 000865259.pdf: 3255498 bytes, checksum: 5ab3f0da34d9a2202c8baaada085b6cc (MD5) / A Nanoskin® é uma película de celulose bacteriana produzida pela bactéria Acetobacter xylinum,por meio de um processo biotecnológico. É composta por uma rede de nanofibrilas cuja estrutura cria uma extensa superfície, a qual permite a retenção de grande quantidade de água e importantes modificações em seu formato, sem perder suas características estruturais. Objetivo: visando acrescentar novas possibilidades para a reconstrução da pálpebra, em seus folhetos profundo ou superficial, o presente estudo foi desenvolvido com o objetivo de avaliar se a película de Nanoskin® poderia ser uma opção. Método: foram utilizadas 40 cobaias, do sexo masculino, que receberam fragmentos de Nanoskin® na região dorsal, em dois estudos, um direcionado para a utilização da Nanoskin nos tecidos profundos, quando o biomaterial foi colocado no subcutâneo e outro no qual a Nanoskin foi colocada na superfície da pele. Em ambos os estudos foram utilizados dois tipos de Nanoskin: grupo 1 (G1), no qual foi utilizada película de Nanoskin® (2X2 cm) sem recobrimento de gelatina no subcutâneo ou na superfície da pele e o grupo 2 (G2), que recebeu implante de Nanoskin® (2X2 cm) com revestimento de gelatina no subcutâneo e na superfície da pele. O grupo controle foi obtido com colocação de enxerto de pele de espessura total no tamanho de 2X2 cm, contíguo ao implante de Nanoskin®, em todos os animais de G1 e de G2 do experimento que estudou o biomaterial na superfície da pele. Cinco animais de cada grupo foram eutanasiados em quatro momentos experimentais: 7 dias (M1), 30 dias (M2), 90 dias (M3) e 180 dias (M4). Foram realizadas avaliações morfométricas do implante das lâminas histológicas, exame histológico e exame ultraestrutural. Resultados: a Nanoskin® quando implantada no subcutâneo não foi encontrada em um animal de M3 e em cinco animais de M4. Nos momentos M3, M4 e M5, houve separação entre as suas lamelas. Houve... / The Nanoskin® is a bacterial cellulose film produced by the bacteria Acetobacter xylinum by means of a biotechnological process. It is composed by a network of nanofibrils whose structure creates a large surface area, which allows the retention of a large amount of water and significant changes in its shape without losing its structural characteristics. Purpose: aiming to add new possibilities for the reconstruction of the eyelid, in its superficial or deep lamellae, this study was developed in order to assess whether the Nanoskin® film could be an option. Method: 40 male guinea pig were used, that received Nanoskin® fragments in the dorsal region, in two studies, one directed to the use of Nanoskin® in deep tissue when the biomaterial was placed subcutaneously and another in which the Nanoskin® was placed on skin surface. In both studies we used two types of Nanoskin: group 1 (G1), which was used Nanoskin® film (2x2 cm) without gelatin coating on the subcutaneous or on the skin surface, and Group 2 (G2), which received Nanoskin® implant (2X2 cm) with gelatin coating on the subcutaneous and on the skin surface. The control group was obtained with full-thickness skin graft placement on the size of 2X2 cm Nanoskin® adjacent to the implant in all animals in G1 and G2 experiment that studied the biomaterial on the surface of the skin. Five animals from each group were euthanized at four experimental times: 7 days (M1), 30 days (M2), 90 days (M3) and 180 days (M4). Morphometric assessments of the implant and the histological slides were held, histological and ultrastructural examination. Results: the Nanoskin® when implanted subcutaneously was not found in one animal from M3 and in five animals from M4. In moments M3, M4 and M5, there was separation between their lamellae . There was a significant inflammation at the beginning of the experiment which reduced the following times, and formation of a pseudocapsule around the ...
22

Estudo comparativo entre as esferas de silicone gelatinosas e rígidas em cavidade eviscerada de coelho /

Kanamura, Mayumi Shirota. January 2011 (has links)
Orientador: Silvana Artioli Schellini / Banca: Suzana Matayoshi / Banca: David Araf / Resumo: Apesar da existência de inúmeros tipos de implantes para reposição de volume em cavidades anoftálmicas, até o momento, nenhum deles pode ser considerado ideal, o que faz com que seja necessário continuar buscando novas soluções. Avaliar a biocompatibilidade de esferas de silicone gelatinosas e rígidas, quando colocadas em cavidades evisceradas de coelhos, comparando-as. Estudo prospectivo e experimental, no qual foram utilizados 30 coelhos albinos, espécie Orictolagus cuniculus, submetidos à cirurgia de evisceração do olho direito, sendo feita a colocação de esferas de silicone gelatinosas ou rígidas na cavidade escleral. Os animais foram sacrificados sete, 30 e 90 dias após a colocação das esferas. Os parâmetros avaliados foram: avaliação clínica diária, ultrassonografia da cavidade eviscerada 15 dias após o procedimento, análise histológica do conteúdo orbitário sete, 30 e 90 dias após a cirurgia, com análise morfométrica da pseudocápsula que se formou ao redor das esferas. Os resultados obtidos foram submetidos à avaliação estatística para comparação dos resultados entre e dentro dos grupos experimentais. Durante o seguimento, ocorreram três extrusões de esferas, duas das quais pertencentes ao grupo das esferas rígidas e uma, do grupo das esferas gelatinosas. O exame ultrassonográfico mostrou ausência de coleções ou processo inflamatório ao redor das esferas e boa integração das mesmas com os tecidos orbitários. Ao exame histológico observou-se semelhança de resposta tecidual com ambas as esferas. O exame morfométrico apontou para superioridade das esferas gelatinosas no tocante a espessura da pseudocápsula, que foi menos espessa, principalmente na avaliação feita no setor posterior da cavidade escleral. Todos os parâmetros estudados mostraram que as esferas de silicone... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Despite the existence of many types of implants for volume replacement in anophthalmic sockets, so far, none can be considered ideal implant, which makes it necessary to continue searching for new solutions. To evaluate the biocompatibility of soft and rigid silicone spheres placed in scleral cavities of eviscerated rabbits, comparing them. Prospctive and experimental study using 30 rabbits, specie Orictolagus cuniculus, underwent evisceration surgery of the right eye and replacement of orbital volume with spheres composed by gelatinous (soft) or rigid silicone. The animals were sacrificed seven, 30 and 90 days after surgery. The studies parameters were: daily clinical assessment, ultrasound of the orbit 15 days after the procedure, histological analysis of the orbital contents seven, 30 and 90 days after surgery and morphometric evaluation in the pseudocapsule in all the animals. Statistical analysis for comparison between and within groups was done. During follow-up occurred three spheres extrusions, two of which belonging to the group of rigid spheres and one from gelatinous sphere group. Ultrasound examination showed no inflammation or collections around spheres and good integration with the orbital tissues. The histological evaluation proved both materials had similar response and the morphometric evaluation showed thinner pseudocapsule formation around the gelatinous sphere, mainly in the posterior scleral region. All the parameters evaluated showed both spheres had good tecidual integration to the orbital tissue in rabbit eviscerated eyes. Therefore, gelatinous silicone sphere induced thinner psedudocapsule formation. The authors agree the gelatinous silicone spheres might be helpful to be used... (Complete abstract click electronic access below) / Mestre
23

Avaliação da ação do laser de baixa intensidade sobre a cápsula de implantes mamários de silicone : estudo experimental em ratos /

Palhares Neto, Aristides Augusto. January 2008 (has links)
Resumo: Clicar acesso eletrônico abaixo. / Abstract: Click electronic access below. / Orientador: Silvana Artioli Schellini / Coorientador: Claudia Helena Pellizzon / Banca: Fausto Viterbo de Oliveira Neto / Banca: Antonio de Castro Rodrigues / Banca: José Carlos Ronche Ferreira / Banca: Patrícia Mitiko Santello Akichi / Doutor
24

Influência do ultra-som externo na arquitetura histológica da cápsula orgânica dos implantes de silicone liso : estudo experimental em ratos /

Mendes, Flávio Henrique January 2003 (has links)
Orientador: Fausto Viterbo de Oliveira Neto / Resumo: Resumo completo, clicar acesso eletrônico abaixo. / Abstract: Complete abstract click electronick address below. / Doutor
25

Avaliação da ação do laser de baixa intensidade sobre a cápsula de implantes mamários de silicone: estudo experimental em ratos

Palhares Neto, Aristides Augusto [UNESP] 21 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-21Bitstream added on 2014-06-13T20:00:28Z : No. of bitstreams: 1 palharesneto_aa_dr_botfm_prot.pdf: 1202103 bytes, checksum: dc5c2e95ccd97da8c7df3c1c3ac92ac8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Fundação para o Desenvolvimento Médico e Hospitalar (Famesp) / Clicar acesso eletrônico abaixo. / Click electronic access below.
26

Efeito da administração da Deslorelina por 70 dias na forma de implante na dinâmica folicular, perfil endócrino e expressão de receptores endométriais de estrógeno, progesterona e ocitocina de vacas nelore (Bos taurus indicus) /

Marques Filho, Wolff Camargo. January 2011 (has links)
Orientador: João Carlos Pinheiro Ferreira / Banca: Nereu Carlos Prestes / Banca: Sony Dimas Bicudo / Banca: Inês Cristina Giometti / Banca: Jeanne Broch Siqueira / Resumo: O objetivo deste foi avaliar os efeitos da utilização de implantes subcutâneos de Deslorelina (agonista de GnRH-Suprelorin®) por 70 dias sob a dinâmica folicular, secreção de FSH, LH e P4 e, a expressão gênica e proteica dos receptores endometriais de estrógeno e (E R e E R), de progesterona isoformas A e B (PABR e PBR) e de ocitocina (OTR) em vacas Nelore (Bos taurus indicus). Foi sincronizada a ovulação de 15 vacas Nelore com escore de condição corporal (ECC) 3 e, no D0 foram aleatoriamente selecionados 7 animais para serem submetidos a implantação subcutânea de Deslorelina por 70 dias. O exame ultra-sonográfico foi realizado para caracterização da dinâmica folicular e os folículos foram classicados em classes: I (< 0,4 cm), II (0,4-0,6cm) e III (> 0,6cm). Amostras de sangue foram coletadas para mensuração das concentrações plasmáticas de FSH, LH e P4. A pulsatilidade e os picos de LH foram determinados a partir de amostras sanguíneas coletadas a cada 15 minutos por 6 horas em 4 vacas escolhidas aleatoriamente nos D20 e D62. A mensuração da expressão proteica dos E R, E R, PABR e PBR no epitélio glandular e estroma uterino foram mensurados por meio da técnica da imunoistoquímica e, a expressão gênica dos E R, E R, PABR e OTR foi avaliada com auxílio da técnica de qRT-PCR, ambas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective this study is to evaluate the effects of subcutaneous implant Deslorelin (GnRHa-Suprelorin®) by 70 days on the endocrine dynamic, the follicular development and, gene and protein expression of endometrial receptors of estrogen and (E R and E R), progesterone isoforms A and B (PABR and PBR), and oxytocin (OTR) of Nelore (Bos taurus indicus) cows . Ovulation of 15 Nelore cows with BCS 3 was synchronized following of implantation of Deslorelin in 7 animals for 70 days. During this period, the ovaries were scanned by ultrasonography to characterize the follicular dynamics, where the follicles were divided in class: I (< 0.4 cm), II (0.4-0.6 cm) and III (> 0.6 cm). Blood samples were collected before of each ultrasonographic exam for later measurement of plasma FSH, LH and P4. The assessment of LH pulsatile secretion was measured on blood samples collected every 15 minutes for six hours through the jugular catheterization in fourrandomly chosen cows on D20 and D62. The protein expression of E R and E R, PABR and PBR of endometrial glandular epithelial and stromal was measured using the technique of immunohistochemistry and the quantification of gene expression of E R, E R, PABR and OTR by qRT-PCR technique from fragments collected through endometrials biopsies on days 0, 4, 20 and 27. Others two samples of endometrium were used for. The comparison between the moments of the measures was performed using the nonparametrics tests of the Friedman and Fisher's Exact. The relationship between the results of follicular dynamics, gene and protein expression was performed by Pearson correlation, all with a significance level of 0.05. During the 70 days of implantation of Deslorelin neither animal ovulated, indicating that the preovulatory peak of LH was abolished. The maximum number of follicles... (Complete abstract click electronic access below) / Doutor
27

O uso de implantes orbitários no reparo de cavidades anoftálmicas /

Soranz Filho, João Edward. January 2011 (has links)
Orientador: Cláudia Helena Pellizon / Banca: Silvana Artioli Schellini / Banca: Cláudia Valeria Seullner Brandão / Resumo: Alterações oculares, em especial a perda de volume nas cavidades evisceradas, promovem uma série de modificações ao paciente tanto funcional do órgão quanto psicológica e estética. Uma grande preocupação ao longo do tempo é a procura de um material que possa preencher o volume perdido de forma a dar um maior conforto no ponto de visto psicológico e estético ao paciente. Para contribuir nessa direção, esse trabalho teve como objetivo testar experimentalmente prótese de polietileno granulado de ultra-alto peso molecular, material de baixo custo, em órbitas de coelhos submetidos à evisceração cirúrgica em vários tempos experimentais, onde foram avaliados aspectos macroscópicos e microscópicos e de toxicidade sistêmica do material. Os resultados desse trabalho mostram que o material utilizado no implante de cavidade não apresenta alteração significativa nos parâmetros analisados quando comparados ao grupo controle. Sendo resultados bastante promissores indicando que o implante de polietileno poroso desenvolvido por uma indústria nacional tem alto potencial para se realizar testes em humanos / Abstract: Ocular changes especially the loss of volume in eviscerated cavities promotes several modifications to patients - organ functioning and psychological and esthetical changes. A material that could replace the lost volume in order to guarantee to patients more psychological and esthetical comfort has long been worryingly searched. Contributing in this direction this work aimed at testing experimentally a prosthesis polyethylene granulate of ultra-high molecular weight made of a low cost material to be implanted in orbit of rabbits through surgical evisceration during several experimental times to assess macroscopic and microscopic aspects of systemic toxicity of the respective material. The results show that the material used for the implant of the prosthesis in the cavity does not present significant alteration in the analysed parameters when compared to the control group. Thus, we point with this study promising results indicating that the porous polyethylene implant developed by a national enterprise presents high potential to be tested in humans / Mestre
28

Influência da Superfície do implante e da laserterapia na osseointegração, em ratas osteopênicas /

Barbara, Mary Anne Moreira. January 2009 (has links)
Orientador: Luana Marotta Reis de Vasconcellos / Banca: Yasmin Rodarte Carvalho / Banca: Carlos Eduardo Dias Colombo / Resumo: Com o aumento da expectativa de vida da população é importante o estudo de tratamentos alternativos e de biomateriais que visam auxiliar no processo de osseointegração em pessoas com osteoporose. O presente estudo avaliou e comparou a osseointegração de implantes cilíndricos de superfície porosa com implantes cilíndricos de superfície rugosa, ambos de titânio, em ratas osteopênicas e normais, por meio de análise histológica e histomorfométrica. Avaliou também a influência do tratamento com laser de baixa potência (Arseneto de Gálio Alumínio) sobre a osseointegração. Os implantes foram inseridos em 84 ratas, cada rata recebeu um implante poroso no fêmur esquerdo e um implante rugoso no direito. Quarenta e dois dos animais foram submetidos à cirurgia de ovariectomia (OVZ) e 42 foram falsamente operados (SHAM). Após um mês, as ratas foram divididas em 4 grupos, com 21 animais cada, de acordo com o tratamento recebido: a) grupo 1 (SHAM): cirurgia de colocação dos implantes (CI); b) grupo 2 (SHAM): CI e aplicação do laser de baixa potência (LLLT); c) grupo 3 (OVZ): CI; d) grupo 4 (OVZ): CI e LLLT. Sete animais de cada grupo, selecionados aleatoriamente, foram sacrificados 2, 4 e 6 semanas após a cirurgia, os fêmures contendo os implantes foram submetidos à análise histológica e histomorfométrica. Na análise histológica observou-se que houve osseointegração em ambos implantes nos diferentes grupos. Após avaliação da análise histomorfométrica verificou-se que o grupo 4, os implantes do tipo poroso, com animais sacrificados 4 semanas após a cirurgia de implante exibiu maior porcentagem de neoformação óssea, seguido do grupo 2, com implante poroso 4 e 6 semanas de período de sacrifício. Concluiu-se que a laserterapia melhora significantemente a neoformação óssea e que os implantes de superfície porosa apresentam maior área para contato na interface osso-implante. / Abstract: With increasing life expectancy of the population is important to the study of alternative treatments and biomaterials which aim to assist in the process of osseointegration in people with osteoporosis. .This study involved an assessment and comparison of the osseointegration of cylindrical titanium implants with porous surfaces and with rough surfaces in osteopenic rats, based histological and histomorphometric analyses. An evaluation was also made of the influence of low level laser therapy (LLLT) with gallium-aluminum arsenate (Ga-Al-As) on osseointegration. The implants were placed in 84 rats, two per rat, i.e., a porous implant in the left femur and a rough implant in the right femur Forty-two of the animals were then ovariectomized (OVZ) while the other 42 were subjected to a sham ovariectomy (SHAM). After one month the rats were divided randomly into four groups of 21 animals each, according to treatment received: a) group 1 (SHAM) implant surgery (IS); b) group 2 (SHAM) IS and low-level laser therapy (LLLT); c) group 3 (OVZ): IS; d) group 4 (OVZ) IS and LLLT. Seven animals from each group were selected randomly and killed 2, 4 and 6 weeks after surgery and the histomorphometric analyses. The histological analysis revealed that osseointegration occurred in both types of implants in all the groups. The histomorphometric analysis indicated that the porous implants in the group 4, killed 4 weeks after implantation, showed the highest percentage of new bone formation, followed by the porous implants in group 2, killed 4 and 6 weeks after implantation. It was concluded that laser therapy significantly improves new bone formation and that implants with porous surfaces have a larger contact area at the bone-implant interface. / Mestre
29

Obtenção e processamento de matrizes tridimensionais de colágeno e implantação em parede abdominal de eqüinos /

Vulcani, Valcinir Aloísio Scalla. January 2008 (has links)
Orientador: Delphim da Graça Macoris / Banca: Ana Maria de Guzzi Plepis / Banca: Luis Cláudio Lopes Correia da Silva / Banca: José Wanderley Cattelan / Banca: Antonio Carlos Alessi / Resumo: Neste trabalho, objetivou-se, a obtenção de biomembranas a partir de centros tendinosos diafragmáticos de eqüinos submetidos a soluções alcalinas por diferentes períodos de tempo. As amostras foram tratadas durante 24, 48, 72, 120 e 144 horas em solução alcalina, liofilizadas e analisadas quanto à flexibilidade, viabilidade para sutura e homogeneidade. Em seguida, as amostras obtidas e o material in natura foram caracterizados por calorimetria exploratória diferencial, microscopia eletrônica de varredura e ensaio de degradação enzimática pela colagenase. As membranas tratadas por 72 horas em solução alcalina se mostraram mais homogêneas e flexíveis em relação às membranas tratadas por tempos menores e mais resistentes à sutura em relação às tratadas por tempos maiores em solução alcalina. A calorimetria exploratória diferencial demonstrou que não houve desnaturação do colágeno após o tratamento alcalino. Concluiu-se que o tratamento por 72 horas é o mais indicado para a implantação cirúrgica na parede abdominal de eqüinos. / Abstract: The objective of this work was to obtaining biomembranes from equines tendineous diaphragmatic centers submitted to alkaline solutions at different times. The samples were treated during 24, 48, 72, 120 and 144 hours in alkaline solution and analyzed the flexibility, viability for suture and homogeneity. After that, the samples and the material in natura were characterized by diferential scanning calorimetry, scan ning electronic microscopy and biological stability in vitro hydrolysis of collagen by colagenase. The 72 hours alkaline treatment showed be intermediary in relation to flexibility, suture resistance and homogeneity. diferential scanning calorimetry demonstrated that the alkaline treatment did not have denaturated the collagen. It 23 was concluded that the treatment for 72 hours is the most indicated for the surgical implantation. / Doutor
30

Implante de parafuso pedicular nas regiões torácica e lombar da coluna : um estudo comparativo retrospectivo entre neuronavegação e fluoroscopia intra-operatória / Vinícius de Paula Guedes ; orientador, Elisagela Ferretti Manffra ; co-orientador, Luiz Roberto Aguiar

Guedes, Vinícius de Paula January 2010 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Bibliografia: f. 75-84 / A técnica de cirurgia guiada por imagem (neuronavegação) utilizada para o implante de parafusos pediculares na coluna torácica e lombar é um método efetivo, seguro e exato quando comparada com a técnica utilizando a fluoroscopia. Apesar disso, ainda exist / Neuronavigation for thoracic and lumbar spine screw pedicle placement is considered an effective, safe and precise method when compared to fluoroscopy. However, results concerning time required for pedicle screw implantation and blood loss in both techniq

Page generated in 0.0787 seconds