• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 851
  • 34
  • 32
  • 32
  • 31
  • 23
  • 9
  • 9
  • 9
  • 7
  • 5
  • 5
  • 3
  • 2
  • Tagged with
  • 881
  • 881
  • 560
  • 490
  • 219
  • 205
  • 156
  • 118
  • 104
  • 98
  • 87
  • 85
  • 83
  • 81
  • 76
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise Microscópica de Rebordos Alveolares Maxilares Reconstruídos com Enxertos Autógenos de Crista Ilíaca e Região Mentoniana. / Microscopical analysis of reconstructed maxillary alveolar ridges using iliac crest and chin autogenous bone grafts

Mariza Akemi Matsumoto 24 November 1999 (has links)
A instalação de implantes osseointegrados em rebordos atróficos reconstruídos com a utilização de enxertos ósseos autógenos vem sendo amplamente utilizada, principalmente com a adoção de dois tempos cirúrgicos . Neste estudo, buscou-se, à luz da microscopia óptica, avaliar o reparo e a qualidade óssea obtidos em rebordos maxilares que receberam enxertos de duas zonas doadoras, a crista ilíaca e o mento. Para tanto, dez pacientes submetidos à este tipo de reconstrução integraram a amostra. No período de quatro meses após este procedimento cirúrgico, no momento da colocação dos implantes, foram obtidos cinco espécimes de cada tipo de enxerto, por meio de biópsias realizadas com brocas trefinas. As peças cirúrgicas passaram por procedimento histotécnico de rotina e foram coradas pelas técnicas de H.E. e Tricrômico de Mallory. Como resultados, verificou-se tecido ósseo em franco processo de remodelação, evidenciado pelas numerosas áreas de osteogênese presentes em ambos os enxertos. Da análise das superfícies de matriz óssea mineralizada obteviveram-se valores significativamente maiores para as regiões que receberam enxerto de mento. Desta forma, concluiu-se que o período de quatro meses se mostrou suficiente para a incorporação dos enxertos, sendo viável a instalação dos implantes neste momento. Quanto à qualidade óssea, os enxertos de mento apresentaram-se superiores aos de ilíaco, possivelmente devido à sua arquitetura original. / The insertion of endosseous implants in atrophic ridges reconstructed with autogenous bone grafts has been extensively used, most of the times using two-stage technique. In this study, bone graft repair and bone quality achieved in maxillary ridges reconstructed using iliac crest and chin bone grafts were analysed under light microscopy. Ten patients who underwent this procedure were observed in this study. After 4 months of the bone graft surgery, at the moment of the implants installation, 5 specimens were obtained from biopsies made in each bone graft group using trephine burs. The specimens underwent routine histotechnical procedure and stained by H.E. and Mallory triple stain. As a result, process of bone turnover was revealed by the areas of intense osteogenesis. From the analysis of mineralized bone tissue surface areas, significant greater values were verified in maxillary ridge regions reconstructed with chin graft. From these results, it was concluded that the period of 4 months was sufficient to the incorporation of the grafts. It was also concluded that chin grafts presented better bone quality than iliac crest grafts.
12

Efeito de duas diferentes rugosidades do intermediário de titânio no aspecto histológico do tecido peri-implantar de pacientes utilizando sobre-dentadura.

Ishikiriama, Sérgio Kiyoshi 24 April 2000 (has links)
O sucesso da osseointegração depende, entre outros fatores, da integridade da interface entre os tecidos moles peri-implantares e componente intermediário do implante. Nesta região ocorre um vedamento que separa o meio interno e externo, responsável pela manutenção a longo prazo da osseointegração. Para que este mecanismo ocorra com êxito, é necessário que os tecidos moles possam exercer suas funções normais em um ambiente livre de inflamação e contaminação bacteriana. Levando-se em conta que os intermediários acumulam placa bacteriana devido à sua rugosidade superficial, o presente trabalho objetivou determinar a influência desta rugosidade na inflamação dos tecidos moles peri-implantares. Dois intermediários com diferentes rugosidades (intermediário padrão e polido) foram colocados em dez pacientes portadores de sobre-dentaduras inferiores, retidas por dois implantes do sistema NAPIO, desenvolvido na Faculdade de Odontologia de Bauru – USP, por um período de 3 meses. Após este período, biópsias foram realizadas e analisadas em microscópio de luz comum. A contagem morfométrica celular indicou que os tecidos moles peri-implantares ao redor dos intermediários polidos (grupo teste) apresentaram-se com uma quantidade média significantemente menor de linfócitos, quando comparados ao grupo controle (p<0.05). Portanto, a lisura superficial obtida no processo de polimento utilizado no presente trabalho foi considerada satisfatória no que tange a minimizar a inflamação dos tecidos moles peri-implantares e sugere-se que as superfícies dos intermediários devam ser o mais lisas possível no intuito de facilitar o controle de placa pelo próprio paciente. / The osseointegration success depends on the integrity of the interface between abutment and peri-implant soft tissues. In this region, a seal closes the opening between the oral mucosal and the implant, preventing the ingress of bacteria, plaque and other debris into the tissues of the internal environment and it is responsible for the long term maintenance of osseointegration. To acquire a complete seal, soft tissues must be free of inflammation and bacterial contamination. Since superficial roughness of abutments can facilitate the bacterial plaque accumulation, the aim of the present study was to determine the relation between abutment roughness and soft tissue inflammation. Abutments with 2 different levels of roughness (standard and polished abutment) were installed in 10 pacientes treated with mandibular overdentures anchored by 2 implants (NAPIO). After a period of 3 months, biopsies were removed and analyzed on a light microscope. The cell morfometric results showed that soft tissues around polished abutments harbored significantly less linfocytes than soft tissues around standard abutments. Therefore, the reduced superficial roughness presented on polished abutments successfully minimized the soft tissue inflammation and it is suggested that abutment surface should be as polished as possible to allowed a better plaque control by patients.
13

Influência do momento e posicionamento de instalação do implante na formação óssea peri-implantar em diferentes tratamentos de superfície

Passoni, Bernardo Born January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T18:02:01Z (GMT). No. of bitstreams: 1 326581.pdf: 3035055 bytes, checksum: 095d3c7a9b9f63dfed812985a304d6da (MD5) Previous issue date: 2014 / Objetivos: verificar a influência do momento de instalação e do posicionamento do implante, bem como a presença ou não do GAP vestibular, associado ao seu tratamento de superfície, na formação óssea ao redor dos implantes. Materiais e métodos: Em um primeiro momento 3 pré-molares de um lado da arcada de 07 cães mongrel foram extraídos. Após 120 dias de cicatrização alveolar, em um segundo ato cirúrgico neste sextante, foi elevado um retalho de espessura total e foram instalados 3 implantes. Na mesma cirurgia os pré-molares contralaterais foram extraídos e feita a instalação imediata de 3 implantes, por meio da técnica do approach palatino, sem o rebatimento de retalho, totalizando 6 implantes por animal. Os 42 implantes instalados formaram grupos de acordo com o momento (imediato ou tardio) da instalação do implante e do tratamento de superfície. Após 4 meses do segundo ato cirúrgico realizou-se a coleta das amostras e a análise histomorfométrica, afim de se observar: BIC vestibular, BIC lingual, BIC total, área vestibular e área lingual de todos os implantes. Para análise estatística utilizou-se os testes Kruskal-wallis e Wilcoxon pareado (p <0,05) Resultados: Após 4 meses de cicatrização, observou-se que os grupos referentes aos implantes imediatos obtiveram melhores taxas de BIC, sobre tudo na face vestibular. Os dados também sugerem uma vantagem na área óssea ao redor dos implantes nestes mesmo grupos. Quanto ao tratamento de superfície, melhores resultados foram encontrados para jateamento de partículas + ataque-ácido. Conclusão: Conclui-se que a técnica cirúrgica flapless com approach palatino, o tratamento de superfície e o instalação imediata dos implantes tem influência favorável na formação óssea ao seu redor.<br> / Abstract : Objective: To investigate the influence of time of placement and positioning of the implant, the presence or absence of the buccal GAP, associated with its surface treatment on bone formation around the implants. Materials and methods: At first 3 premolars from one side of the arch of 07 mongrel dogs were extracted. After 120 days of alveolar healing, in a second surgery on this side, a full flap was elevated and 3 implants were placed. At the same surgery, the contralateral premolars were extracted and a immediate placement of 3 implants were done using the flapless technique of palatal approach. Resulting in a total of 6 implants per animal. The groups were formed according to the time of implant placement and surface treatment. 4 months after the second surgery was performed the sample collection and histomorphometric analysis to investigate: buccal BIC, lingual BIC, full BIC, buccal area and lingual area of all implants. Results: After 4 months of healing, it was observed that groups related to immediate implants showed better rates of BIC, especially on the buccal bone. The data also suggest an advantage in the bone area around the implants in these same groups. About surface treatment, the best results were found for sand-blasting + acid attack. Conclusion: It is concluded that performing the flapless surgical technique with palatal approach, the surface treatment and the time of implant placement have favorable effect on bone formation around them.
14

Efeitos do ranelato de estrôncio sobre o tempo de osseointegração de implantes dentários de titânio instalados em tíbia e em fêmur de coelhos” / The effect of srontrium ranelate in the osseontegration of dental implants in tibia and femur of rabbits

Magalhães, Glívia Maria Silveira January 2009 (has links)
MAGALHÃES, Glívia Maria Silveira. Efeito do ranelato de estrôncio sobre o tempo de osseointegração de implantes dentários de titânio instalados em tíbia e em fêmur de coelhos. 2009. 68 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2009. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-08T15:50:09Z No. of bitstreams: 1 2009_dis_gmsmagalhães.pdf: 1549469 bytes, checksum: f0afe7c1abe716e632f8a103746431c8 (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-01T13:58:09Z (GMT) No. of bitstreams: 1 2009_dis_gmsmagalhães.pdf: 1549469 bytes, checksum: f0afe7c1abe716e632f8a103746431c8 (MD5) / Made available in DSpace on 2012-02-01T13:58:09Z (GMT). No. of bitstreams: 1 2009_dis_gmsmagalhães.pdf: 1549469 bytes, checksum: f0afe7c1abe716e632f8a103746431c8 (MD5) Previous issue date: 2009 / The integration of titanium dental implants in bone has been reported extensively over the last few decades beginning with the original work of Branemark and co-workers. The use of titanium endosseous dental implants in the treatment of edentulous or partially edentulous patients has become an alternative to restore function and esthetics, however, this results depend on the quantity and quality of the maxillary or mandibular bone. Osteoporosis is a disease that influences the quality of bone tissue such that it may become susceptible to fracture. Significant relationship have been reported between oral bone and skeletal bone mass in postmenopausal women. Osteoporosis could, therefore be considered a risk factor for osseointegration of dental implants, but this is still controversial. Strontium ranelate is a new therapy for the treatment and prevention of osteoporosis that may dissociate bone formation and bone resorption by allowing continued production of bone while decreasing bone resorption. The purpose of this study was to determine the effect of systemic strontium ranelate therapy on early dental implant osseointegration based on torque-removal values in rabbits. Sixty-four identical titanium dental implants were placed using a standardized surgical protocol in the bilateral distal femur and proximal tibia of 16 New Zealand white rabbits (64 implants total). One week before implant placement, 8 rabbits were given doses of strontium ranelate (625mg/kg/day) until euthanized. The other 8 rabbits were untreated controls. One rabbit of each group were sacrificed in time of 15, 30, 45, 60, 75, 90, 105, 120 days, and torque-removal values were determined using a digital torque wrench for all implants. Analyses of torque data showed no statistical differences between the strontium ranelate and control groups. Based on the findings of this study, we can conclude that the time of 15 to 120 days of strontium ranelate administration does not interfere with the timing of early dental implant osseointegration in an animal model. / A integração dos implantes dentários no osso tem sido amplamente relatada nas últimas décadas desde os trabalhos originais de Branemark e co-autores. O uso de implantes dentários de titânio no tratamento de pacientes edêntulos ou parcialmente edêntulos tem se tornado uma alternativa para restauração funcional e estética, entretanto esses resultados dependem da quantidade e da qualidade do osso maxilar ou mandibular. Osteoporose é uma doença que influencia a qualidade do tecido ósseo, tornando-o susceptível à fratura. Relação importante tem sido descrita entre massa óssea oral e esquelética em mulheres pós-menopausa. A osteoporose tem sido considerada um fator de risco para a osseointegração de implantes dentários, embora o assunto ainda seja bastante controverso. O ranelato de estrôncio é uma nova terapia para o tratamento e prevenção da osteoporose, que dissocia a formação óssea da reabsorção óssea permitindo continuada produção de osso enquanto diminui a sua reabsorção. O objetivo do presente trabalho foi determinar, em coelhos, o efeito da terapia sistêmica com ranelato de estrôncio sobre o tempo de osseointegração de implantes dentários baseado nos valores do torque para a sua remoção. Sessenta e quatro implantes dentários de titânio idênticos foram, então, instalados, seguindo protocolo cirúrgico padronizado, na distal do fêmur e proximal da tíbia, bilateralmente, de 16 coelhos brancos da raça Nova Zelândia (64 implantes no total). Uma semana antes da instalação dos implantes, foi iniciada a administração de doses de ranelato de estrôncio (625mg/kg/dia) a 8 coelhos prorrogada até o sacrifício desses animais. Os outros 8 coelhos pertenciam ao grupo controle, sem medicação. Um coelho de cada grupo foi sacrificado com 15, 30, 45, 60, 75, 90, 105 e 120 dias e os valores do torque para a remoção dos implantes foi determinado por um torquímetro digital. A análise dos dados desses torques mostrou que não houve nenhuma diferença estatística entre o grupo experimental e o grupo controle. Com base nos achados do presente trabalho, concluiu-se que o tempo de 15 até 120 dias de uso de ranelato de estrôncio não interferiu no tempo de osseointegração.
15

Análise de liberação in vitro da sinvastatina associada ao PLGA na supergície de titânio

Salazar Littuma, Gustavo Javier January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2017. / Made available in DSpace on 2017-06-27T04:21:11Z (GMT). No. of bitstreams: 1 346672.pdf: 1115107 bytes, checksum: ca5b0ab14719a45ce782c4d5a13bbb15 (MD5) Previous issue date: 2017 / Novas técnicas e superfícies de implantes têm sido desenvolvidas para acelerar a formação óssea e consequentemente diminuir o tempo de osseointegração. Os sistemas de liberação controlada de fármacos por meio de agentes carreadores, como os polímeros biodegradáveis, buscam proporcionar, por um longo período de tempo, efeitos terapêuticos, permitindo que o agente seja liberado diretamente no local de ação. O objetivo deste trabalho foi investigar o perfil de liberação da sinvastatina associada ao PLGA (ácido polilático co-glicólico), os quais formaram uma película de revestimento sobre a superfície de discos de titânio, e identificar as características topográficas,físicas e químicas presentes neste revestimento. O estudo envolveu uma técnica de revestimento por imersão dos discos de titânio de 8mm de diâmetro por 3mm de espessura no copolímero de PLGA e sinvastatina. A liberação da Sinvastatina foi avaliada em quadriplicata nos discos com o copolímero em um meio contendo PBS por até 600 horas. A caracterização físico-química e topográfica do PLGA associado à Sinvastatina foi avaliada por espectroscopia de infravermelho transformada de Fourier (FTIR) e calorimetria diferencial exploratória(DSC), já a caracterização topográficado PLGA e Sinvastatina sobre o titânio foi avaliada por microscopia eletrônica de varredura (MEV), microscopia de força atômica(AFM) e a rugosidade média (Ra) por perfilometria. Foi observada uma liberação lenta e prolongada da sinvastatina em PBS, alcançando 21,31% após 25 dias de liberação, e verificou-se que o mecanismo que controla a transferência de massa da sinvastatina é difusional.As análises de FTIR e DSC revelaram que houve incorporação da sinvastatina dentro do polímero. A microscopia pelo MEV e AFM evidenciou uma superfície de revestimento uniforme inicial, que foi mudando ao final de 25 dias de imersão em PBS ao ser analizada pelo MEV devido às características de erosão do PLGA. Os resultados de perfilometria não mostraram diferença estatística na rugosidade média entre o Grupo de PLGA e Sinvastatina+PLGA. A liberação da sinvastatina através do PLGA na superfície de titânio foi lenta e prolongada, o que permite considerar a utilização destes agentes como revestimento terapêutico em implantes dentários.<br> / Abstract : New techniques and implant surfaces have been developed to accelerate bone formation and consequently, decrease the time of osseointegration. Controlled drug delivery systems by carrier agents such as biodegradable polymers seek to provide therapeutic effects over a long period of time allowing the agent to be released directly into the site of action. The objective of this study was to investigate the release profile of simvastatin associated with Poly(lactic-co-glycolic acid) (PLGA), which formed a coating film on the surface of titanium disks, and to identify the topographic,physical, and chemical characteristics present in this coating. The study involved a dip coating technique of titanium discs with 8mm of diameter and 3mm of thickness in the copolymer of PLGA and Simvastatin. The release of simvastatin was evaluated in four replicates on the disks with the copolymer in a medium containing PBS for up to 600 hours. The physico-chemical characterization of PLGA associated with simvastatin was evaluated by fourier transform infrared spectroscopy (FTIR),and differential scanning calorimetry. The characterization of PLGA and simvastatin on the titanium surface was evaluated by scanning electron microscopy(SEM), atomic force microscopy (AFM) and the mean roughness(Ra)by perfilometry. A slow and prolonged release of simvastatin was observed, reaching 21,31% release rate at 25 days, elucidating that diffusion was the mass transport mechanism of sinvastatin. The FTIR and DSC analysis revealed that there was a simvastatin incorporation into the copolymer. The scanning electron microscopy (SEM) and (AFM) showed the presence of a initial uniform coating surface, which was changed at the end of the 25 days of inmersion in PBS after a new (SEM) analysis, due to the erosion characteristics of PLGA. Observing the results obtain by perfilometry, there was no statistical difference between the Group PLGA and Sinvastatin+PLGA. The release of simvastatin through PLGA on the titanium surface was slow and prolonged, which allows the use of this agents as a therapeutic coating in dental implants.
16

Validade e confiabilidade da caracterização de defeitos ósseos periodontais e peri-implantares por tomografia computadorizada de feixe cônico em diferentes protocolos de aquisição.

Rios, Marcelo de Azevedo January 2014 (has links)
Submitted by ROBERTO PAULO CORREIA DE ARAÚJO (ppgorgsistem@ufba.br) on 2015-07-17T19:59:48Z No. of bitstreams: 1 RIOS, Marcelo de Azevedo.pdf: 2385308 bytes, checksum: 95db292afc362c7f635cbd3bc0c30c73 (MD5) / Made available in DSpace on 2015-07-17T19:59:48Z (GMT). No. of bitstreams: 1 RIOS, Marcelo de Azevedo.pdf: 2385308 bytes, checksum: 95db292afc362c7f635cbd3bc0c30c73 (MD5) / Objetivo: estabelecer a confiabilidade e a validade de medidas realizadas através de tomografias computadorizadas de feixe cônico (TCFC) em defeitos ósseos periodontais e peri-implantares, in vitro, em diferentes protocolos de aquisição, bem como para a classificação de defeitos periodontais e periimplantares. Metodologia: foram confeccionados defeitos de 1, 2 e 3 paredes em mandíbulas humanas com dentes e com dois tipos de implantes (hexágono externo e cone morse). Cada peça anatômica foi tomografada no equipamento KODAK 9000 3D, com variação no voxel (0,0076, 0,2 e 0,4) e na mA (2, 4 e 8 mA) e FOV de 5X3,7 cm. Dois examinadores calibrados foram apresentados aos conceitos de medidas lineares de profundidade, largura, comprimento e altura de defeitos, bem como à classificação quanto ao número de paredes. Em seguida, para cada combinação de voxel e mA, os examinadores realizavam as medidas e classificação, as quais foram repetidas em 3 momentos distintos, com intervalos de 1 semana. Os examinadores podiam fazer modificações de contraste e densidade além de magnificar as imagens para as análise. Os dados obtidos forma tratados estatisticamente no programa R usando o coeficiente de correlação intra-classe buscando a confiabilidade/validade das medidas em termos de concordância, confrontando os valores registrados pelos examinadores com a medida obtida diretamente na peça anatômica com paquímetro digital. Resultados: quanto à validade, para defeitos periodontais, as variações de mA apontaram concordância mediana para altura, alta para comprimento e número de paredes e baixa para largura e profundidade, bem como relação às variações de voxel. Em implantes HE em termo de mA, baixa concordância foi observada para profundidade em qualquer mA e para altura e número de paredes em 8 mA; foi mediana para altura (2 e 4 mA) comprimento (4 e 8 mA) e largura (8mA), sendo as demais concordâncias consideradas altas. Em termos de voxel, foi baixa para profundidade, mediana para altura, comprimento e número de paredes e alta para largura. Em implantes CM em termos de mA, a concordância foi baixa para largura, altura e profundidade (4 e 8 mA) e comprimento (8 mA); mediana para altura (2 mA) e profundidade (2 mA) e alta para comprimento (2 mA) e número de paredes (2 e 4 mA), em termos de voxel, foi baixa para altura e largura, mediana para profundidade e alta para comprimento e número de paredes. A confiabilidade foi alta em praticamente todas as avaliações. Conclusão: variações de voxel não impactaram nos resultados de confiabilidade/validade dos dados seja para defeitos periodontal ou peri-implantares, e que mA menores (2 e 4) foram melhores para avaliações peri-implantares, e não tiveram impacto nas avaliações periodontais. / Purpose: to verify the validity and reliability of linear measurements made with cone beam computed tomography (CBCT) of periodontal and peri-implant infrabony defects, in vitro, with diferent acquisition protocols, as well as to those defects, related to the number of remaining walls surrounding the defects. Metodology: One, two and three walls infra-bony defects were made in dry human mandibles with natural teeth and two kinds of dental implants (external conection and cone morse). Each mandible was scanned on KODAK 9000 3D, with three diferent voxel size (0,076, 0,2 and 0,4) and three diferent mA values (2, 4 and 8 mA), FOV of 5X3,7 cm. Two calibrated examiners were showed to standard concepts about linear meusures as width, heigh, depth and length of defects, as well as to infra-bony remaining wall defect classification. With a week of interval, the examiners performed the image evaluations in different combination of mA and voxel. Statistical analysis were carried out with R software and using the inter-class correlation coeficient (ICC), looking for agreement among both examiners and the real measures from digital calliper (gold standard). Results: validity of mA in periodontal bone deffect evaluation revealed median agreement for heigh, high for length and remaining wall and low for depth and width, the same was observed during voxel evaluation. External conection implants mA validity showed low agreement for depth in all mA and for heigh and remaining wall in 8 mA; median for heigh (2 and 4 mA), length (4 and 8 mA) and width (8mA); the other measurements revaled high agreement. Voxel validity evalution showed low agreement for depth, median for heigh, length and remaining wall and high for width. Cone morse mA validity evaluation shoxed low agreement for width, heigh and depth (4 and 8mA) and length (8mA); median for heigh (2mA) and depth (2 mA) and high por length (2mA) and remaining wall (2 and 4 mA). Voxel evaluation revealed low for heigh and width, median for depth and high for length and remaining wall. Reliability was high for almost all evaluation. Conclusion: voxel variations did not modified validity/reliability results from gold-standard for both periodontal and peri-implant bone deffect evaluations, and 2 and 4 mA revealed an improvement in peri-implant bone deffect evaluation, and did not affected periodontal bone deffect evaluation.
17

Síntese de pós de B-TCP e caracterização de Scaffolds de B-TCP revestidos com polímeros bioabsorvíveis para reparação óssea

Magrin, Gabriel Leonardo January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia, Florianópolis, 2016 / Made available in DSpace on 2016-09-20T04:43:08Z (GMT). No. of bitstreams: 1 340524.pdf: 1227179 bytes, checksum: 595c7fd888031571f3aafdf272327575 (MD5) Previous issue date: 2016 / O objetivo deste estudo foi avaliar a síntese do pó de tricálcio fosfato em fase beta (ß-TCP) e as propriedades mecânicas de arcabouços (scaffolds) compostos ß-TCP recobertos com polímeros bioabsorvíveis, colágeno e poli L-co-D,L ácido lático (PLDLA). O pó de ß-TCP foi obtido por moagem reativa e, então, caracterizado por difração de raios-X e microscopia eletrônica de varredura (MEV/EDS). Scaffolds de ß-TCP foram obtidos pelo método da replica, no qual esponjas de poliuretano são imersas em uma suspensão de ß-TCP e submetidas a tratamento térmico para remoção do poliuretano e sinterização da cerâmica. Colágeno do tipo I ou PLDLA foram usados para recobrir os arcabouços de ß-TCP pelo método de revestimento por imersão (dip coating). Os scaffolds foram separados em quarto grupos, dependendo do material de recobrimento: sem recobrimento (grupo A), duas imersões em colágeno (grupo B), duas imersões em PLDLA (grupo C) e dez imersões em PLDLA (grupo D). As amostras foram caracterizadas por testes de compressão e MEV/EDS. Análises químicas e microscópicas revelaram morfologia apropriada das partículas de pó e a presença ou ausência de recobrimento polimérico nos arcabouços. Os scaffolds recobertos com PLDLA apresentaram uma maior resistência à compressão (grupo D; 0,11 ? 0,054 MPa / grupo C; 0,025 ? 0,015) do que aqueles com recobrimento por colágeno (grupo B; 0,022 ? 0,012 MPa) ou sem recobrimento (grupo A; 0,024 ? 0,012 MPa). Todas as estruturas porosas formaram uma rede de poros altamente interconectada. A porosidade média dos scaffolds de ß-TCP sem recobrimento foi de 86% e o tamanho de poro foi de 738 µm, em média, enquanto os scaffolds recobertos com 10 camadas de PLDLA tiveram uma porosidade média de 44,6% e de 200 a 400 µm de tamanho de poro. O método de recobrimento com PLDLA revelou-se uma potencial estratégia para aumentar a resistência mecânica de materiais cerâmicos porosos, possibilitando à estrutura desenvolvida uma aplicação clínica como enxerto ósseo inlay. <br> / Abstract : The purpose of this study was to evaluate the synthesis of beta phase tricalcium phosphate (ß-TCP) powder and mechanical properties of scaffolds composed of ß-TCP coated with bioabsorbable polymers, namely collagen and poly D,L-lactic acid (PDLLA). ß-TCP powder was obtained by reactive milling and then characterized by X-ray diffraction and scanning electron microscopy (SEM/EDS). ß-TCP scaffolds were obtained by replica method, in which polyurethane foams are immersed in ß-TCP suspension and thereafter submitted to a thermal treatment to remove the polyurethane and sinter the ceramic. Type-I collagen or PDLLA were used to coat the ß-TCP scaffolds by dip coating method. The scaffolds were separated in four groups depending on the coating material: non-coated (group A), double immersion in collagen (group B), double immersion in PDLLA (group C) and ten immersions in PDLLA (group D). Samples were characterized by compressive tests and SEM/EDS. Chemical and microscopic analyses revealed appropriate morphology of powder particles and scaffolds, with or without polymeric coatings. Scaffolds coated with PDLLA showed higher compressive strength (group D; 0.11 ? 0.054 MPa/ group C; 0.025 ? 0.015) than those of collagen (group B; 0.022 ? 0.012 MPa) or non-coated groups (group A; 0.024 ? 0.012 MPa). All the porous structures formed a highly interconnected pore network. The mean porosity ß-TCP scaffolds free of coatings was around 86% and mean pore size of 738 µm, while scaffolds coated with 10 layers of PDLLA had a mean porosity of about 44.6% and 200 to 400 µm of pore size. The coating method of ß-TCP with PDLLA revealed a potential strategy to increase mechanical strength of porous ceramic materials, given to the developed structure a clinical application as inlay bone graft.
18

Análise da microbiota dos sulcos dos implantes de pacientes tratados com implantes dentais

Gibaja, Raynier Omar Aldana January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T15:56:56Z (GMT). No. of bitstreams: 0 / O presente trabalho analisa a qualidade da microbiota dos sulcos dos implantes dentais em humanos mediante a análise de material coletado de sulcos subgengivais. Foram analisadas 11 amostras retiradas do sulco subgengival. Os materiais foram incubados em anaerobiose durante sete dias à 37OC. Placas com meio seletivo para Actinobacillus actinomycetemcomitans foram incubadas em jarra com vela. Após o período de incubação as jarras foram abertas. Colônias de espécies diferentes na morfologia colonial foram repicadas para meio BHI, adicionado de hemina e vitamina K; após o crescimento foram caracterizadas quanto ao Gram e ao tipo respiratório. As amostras retiradas dos implantes saudáveis foram colonizados por estreptococos e bastonetes Gram-positivos. as amostras de implantes com perimplantite foram colonizados por bastonetes Gram-negativos e bastonetes Gram-negativos pigmentados de preto, a amostra do implante com mucosite foi colonizado por estreptococos e bastonetes Gram-negativos. Actinobacillus actinomycetemcomitans não foi detectado.
19

Avaliação da influência da velocidade de perfuração na reabsorção óssea ao redor de implantes osseointegrados instalados por meio de cirurgia guiada sem retalho: estudo clínico, radiográfico e histológico

Landázuri Del Barrio, Ricardo Andrés [UNESP] 19 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-19Bitstream added on 2014-06-13T18:43:56Z : No. of bitstreams: 1 landazuridelbarrio_ra_dr_arafo.pdf: 1068855 bytes, checksum: 6b1cfc32b5ec4d0105c7d549652c1515 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo realizado em humanos e animais foi avaliar clínica, radiográfica e histologicamente a influência da velocidade de perfuração no tecido ósseo peri-implantar em implantes instalados com cirurgia guiada sem retalho. No estudo em animais, 30 implantes foram instalados em ambas as tíbias de 15 coelhos com diferentes velocidades de perfuração (Controle – 1500 r.p.m e Teste – 50 r.p.m.) para avaliação histológica de BIC e BA nos períodos de 4, 8 e 12 semanas. Na segunda parte do estudo, foram realizadas 30 perfurações ósseas nas tíbias de 15 coelhos. A distribuição dos grupos foi de acordo com a velocidade de perfuração utilizada na primeira parte do estudo para avaliação histológica nos períodos de 0, 7 e 14 dias. No estudo em humanos, 64 implantes foram instalados com cirurgia guiada sem retalho em 16 mandíbulas edêntulas. Em cada paciente foram instalados 2 implantes utilizando as duas velocidades de perfuração do estudo em coelhos. A avaliação clínica e radiográfica foi realizada durante 1, 3, 6 e 12 meses. No estudo em coelhos, os 2 grupos mostraram regeneração óssea progressiva na região do defeito sem mostrar diferença estatística. Na avaliação do contato osso-implante e área óssea entre as espiras, não foram observadas diferenças significantes entre os grupos. No estudo clínico foi observado um índice de sucesso de 90% após um ano em função. O nível ósseo médio durante o período experimental foi de 0,83 mm. Treze em 16 próteses pré-fabricadas não apresentaram adaptação confirmada por radiografias periapicais digitais. Três implantes de cada grupo foram perdidos durante o período de avaliação de 3 meses. Um dos implantes perdidos foi avaliado mediante histologia e apresentou necrose na região apical. Não foi observada diferença significante entre os grupos com relação ao IP, SS e à avaliação... / The aim of this study was to evaluate clinical, histologic and radiographically the effect of drilling speed on bone tissue around implants installed with flapless guided surgery. Thirty implants were installed in the tibial metaphysis of 15 rabbits with 2 different drilling speed (Control – 1500 r.p.m and Test – 50 r.p.m.). BIC and BA were assessed during 4, 8 and 12 weeks after implant placement. Then, 30 bone defects were performed in the tibial metaphysis of 15 rabbits with the same drilling speed groups. The histologic evaluation was performed at 0, 7 and 14 days. In the clinical study, 64 implants were installed in 16 edentulous mandibles with flapless guided surgery. Two implants per patient were instaled wtih the same protocol and distribution of drilling speed groups of the animal study and they were clinical and radiographically evaluated during 1, 3, 6 and 12 months. In rabbits, both groups showed progressive bone repair around the defect without statistical differences. No differences between groups were showed in terms of bone implant-contact and bone area. The clinical evaluation showed 90% of implant survival during the experimental period. Mean bone level after 12 months of function was 0.83 mm. A radiographically misfit was observed in 13 of 16 patients between abutment and pre-fabricated prostheses. Three implants of both experimental groups were lost during 3 months evaluation. One implant was assessed histologically and showed apical necrotic bone. No statistical difference between groups were showed at PI, BoP and implant stability. Statistically difference (p<0.05) was showed between groups at mean gray level of bone gain and mean area of bone gain and bone loss evaluation. Within the limitations of this study, it can be concluded that the drilling speed do not have effect on bone repair and it did not present alterations on the osseointegration pattern... (Complete abstract click electronic access below)
20

Análise da distribuição de tensões em implantes curtos e coroas longas, através do método de elemento finito 3-D

Cruz, Rafael Evaristo da January 2016 (has links)
Orientador: Prof. Dr. Nelson Luis Barbosa Rebellato / Coorientador: Prof. Dr. Delson João da Costa / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Odontologia. Defesa: Curitiba, 2016 / Inclui referências : f. 37-44;56-58 / Área de concentração / Resumo: Este estudo analisou através do método de elemento finito tridimensional (MEF) a distribuição de tensões mastigatórias sobre implantes curtos com coroas alongadas, na região do elemento 36. Os modelos de implantes utilizados foram: M1- Neodent Titamax WS® 4x5mm e M2 - Neodent Titamax WS® 5x5mm. A análise verificou a distribuição das tensões nos implantes e no tecido ósseo, sob cargas de incidência axial e oblíqua e avaliou a influência da diferença no diâmetro dos implantes sobre a distribuição das tensões mastigatórias. Os resultados mostraram que sob incidência de forças axiais, os modelos analisados obtiveram resultados satisfatórios, sem exceder os limites de resistência do tecido ósseo e os limites de escoamento dos implantes e componentes protéticos envolvidos. Porém, sob incidência de forças oblíquas, os modelos apresentaram picos de tensão que ultrapassaram os limites de resistência do osso, indicando uma possível reabsorção óssea, de maior evidência no modelo M1. Verificamos um excesso de tensão incidindo sobre o terço cervical dos implantes analisados sob força oblíqua, porém de maior intensidade no modelo M1, podendo levar a uma falha estrutural deste implante. Observamos que o fato de aumentar o diâmetro do implante favoreceu a distribuição das tensões mastigatórias, tanto nos implantes como no tecido ósseo. Conclui-se que o uso de implantes de maior diâmetro possuem um melhor desempenho para dissipar as forças e reduzir a tensão no implante e no osso circunjacente, e que forças oblíquas são potencialmente prejudiciais ao sistema implante/osso, principalmente em implantes curtos com coroas superdimensionadas. A indicação no uso de implantes curtos unitários deve ser cautelosa e o planejamento protético deve ser rigoroso, favorecendo as cargas oclusais ou axiais e minimizando as cargas oblíquas. Palavras-chave: Análise de elementos finitos, implantes dentários, força de mordida. / Abstract: This study analyzed through 3-D finite element method (FEM) simulation of the distribution of masticatory tension on short implants with long length crowns, in 36 region. The CAD SolidWorks® 2015 (Dassault Systemes, Solidworks Corps, USA) and the Ansys Workbench® V16. (Ansys Inc., Canonsburg, PA, USA) softwares were used. The selected implant models were: M1- Neodent Titamax WS® 4x5mm and M2 - Neodent Titamax WS® 5x5mm. The files with the models of implants and abutments were provided by Neodent® company, Curitiba, Brazil. The analysis showed the stress distribution in the bone tissue and implants under axial and oblique forces incidence and evaluated the influence of the difference in diameter of the implants on the distribution of masticatory tensions. The results showed that under effect of axial forces, the models achieve satisfactory results, without reaching or exceeding the strength limits in bone tissue, implants and prosthetic components involved. However, under oblique forces, the models showed maximum tension values exceeding the bone strength limits, indicating a possible bone resorption, more evident in M1. An excess of tension was found on the cervical third of implants analyzed under oblique incidence, but a greater intensity in the M1 led to structural failure of the implant. We note that the fact of increasing the diameter of the short implants favored the distribution of masticatory stress both the implants and the bone tissue. We conclude that the use of larger diameter implants have a better performance to dissipate the forces, and reduce the tension in the walls of the implant and the surrounding bone, and oblique forces are potentially harmful to the implant / bone system, especially for short implants with oversized crown. The indication on the use of single short implants should be cautious and prosthetic planning should be strict, favoring the occlusal or axial loads and minimizing the oblique loads. Keywords: Finite element analysis, dental implants, bite force

Page generated in 0.0966 seconds