• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 851
  • 34
  • 32
  • 32
  • 31
  • 23
  • 9
  • 9
  • 9
  • 7
  • 5
  • 5
  • 3
  • 2
  • Tagged with
  • 881
  • 881
  • 560
  • 490
  • 219
  • 205
  • 156
  • 118
  • 104
  • 98
  • 87
  • 85
  • 83
  • 81
  • 76
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Plataforma regular versus switching: estudo mecânico por meio de testes laboratoriais de fadiga e análise de elementos finitos em implantes com hexágono externo e interno

Freitas Júnior, Amilcar Chagas [UNESP] 30 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-30Bitstream added on 2014-06-13T20:25:50Z : No. of bitstreams: 1 freitasjunior_ac_dr_araca.pdf: 626707 bytes, checksum: 01bcfeff181d77eb6eaa682b52483519 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição. O objetivo do presente trabalho foi avaliar a influência do conceito de plataforma switching na confiabilidade e modo de falha de restaurações unitárias sobre implante com hexágono externo ou interno na região anterior da maxila. Adicionalmente, análises de elementos finitos foram realizadas para avaliar o padrão de distribuição de tensão dentro do complexo pilar-implante e no tecido ósseo peri-implantar. Materiais e Métodos. 84 implantes foram divididos em 4 grupos (n = 21) para realização dos testes de fadiga: SWT-EH e REG-EH (implantes de conexão externa com plataforma switching ou regular, respectivamente); SWT-IH e REG-IH (implantes de conexão interna com plataforma switching ou regular, respectivamente). Análises estatísticas de Weibull foram realizadas considerando as missões de 50.000 ciclos a 210N e 300N. Adicionalmente, foram construídos 4 modelos de elementos finitos considerando as mesmas variáveis para obtenção das tensões equivalentes de von Mises (σvM) no complexo pilar-implante e das máximas tensões principais (σmax) no osso peri-implantar. Resultados. Os valores de Beta para os grupos SWT-EH (1,31), REG-EH (1,55), SWT-IH (1,83) e REG-IH (1,82) indicaram que a fadiga acelerou a falha em todos os grupos. Os valores de confiabilidade calculados para os grupos SWT-EH, REG-EH, SWT-IH e REH-IH foram 0,53 (0,33 - 0,70), 0,93 (0,80 - 0,97), 0,99 (0,93 - 0,99) and 0,99 (0,99 -de tensão estiveram no pilar (SWT-IH = 186 MPa e REG-IH = 88.8 MPa). No osso cortical, os implantes com plataforma switching geraram menor tensão (σmax) tanto para conexão externa (SWT-EH = 49.0 MPa e REG-EH = 56.5 MPa) como para conexão interna (SWT-IH = 37.7 MPa e REG-IH = 45.5 MPa)... / Purpose. The aim of the present study was to evaluate the effect of platform switching concept on reliability and failure modes of anterior single-unit restorations for internal and external hex implants. Additionally, finite element analysis were performed to assess the stress distribution within implant-abutment complex and peri-implant bone. Materials and Methods. 84 implants were divided in 4 groups (n=21) for fatigue tests: REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). Weibull analysis for a mission of 50,000 cycles at 300N was performed. Additionally, 4 three-dimensional finite element models reproducing the characteristics of specimens used in mechanical tests were created to evaluate the equivalent von Mises stress (σvM) within implant-abutment complex and the maximum principal stress (σmax) in the peri-implant bone. Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The calculated reliability for groups SWT-EH, REG-EH, SWT-IH and REH-IH were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), respectively. Failure modes (screw and/or abutment fracture) were similar for regular and switched-platform implants. Within implant-abutment complex, the higher peak of stress (σvM) was observed in fixation screw (SWT-EH = 190 MPa and REG-EH = 160 MPa) for groups with external hex implants; while for groups with internal hex implants was in abutment (SWT-IH = 186 MPa and REG-IH = 88.8 MPa). In the cortical bone... (Complete abstract click electronic access below)
22

Avaliação da prevalência de canais mandibulares bífidos em tomografia computadorizada por feixe cônico

Villaça-Carvalho, Maria Fernanda Lima [UNESP] 12 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-12Bitstream added on 2014-06-13T18:58:43Z : No. of bitstreams: 1 carvalho_mflv_me_sjc.pdf: 376473 bytes, checksum: fd3cb649deb141adcb6ff92fcc6eaeb7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O canal mandibular pode apresentar diferentes morfologias, em alguns casos, existe a presença de um canal acessório chamado bífido. O objetivo deste estudo foi avaliar a prevalência de canais mandibulares bífidos (CMB) por meio de Tomografia Computadorizada por Feixe Cônico (TCFC). Examinaram-se tomografias de 300 pacientes tanto do sexo masculino quanto do feminino, com idade compreendida entre, 25 a 87 anos, submetidos ao exame para avaliação da mandíbula. Os indivíduos foram divididos em dois grupos de acordo com o sexo, GM para o masculino e GF para o feminino, e dois subgrupos de acordo com o lado examinado, D para o direito e E para o esquerdo. Todas as aquisições tomográficas seguiram um mesmo protocolo de aquisição e a análise das imagens se deu num mesmo software. Foram utilizados filtros de imagens associados aos cortes transversais, oblíquos e reconstrução panorâmica para análise do CMB. Realizaram-se análises descritivas dos valores e comparações entre os fatores pelo teste Anova com significância de 95%. Foi possível observar que os CMB ocorreram em 80 casos (26,67%), destes, 39 (48,75%) no sexo masculino e 41 (51,25%) no feminino, não sendo verificadas diferenças nas mensurações comparadas por sexo (masc p=0,788; fem p=0,140) nem por lado acometido (dir p=0,365; esq p=0,412), apesar do direito ter sido mais frequente (66,67%) em ambos os sexos. Desta forma, pode-se concluir que a prevalência dos CMB é significante e não deve ser negligenciada pelos cirurgiões dentistas / The mandibular canal can have different morphologies, in some cases is present a second canal (bifid). The aim of this study was to evaluate the incidence of bifid mandibular canals (BMC) by Cone Beam Computed Tomography (CBCT). Cone beam CT scans of 300 patients, both male and female, aged 25 to 87 years old, who underwent the examination for evaluation of the mandible, were examined. Patients were divided into two groups according to sex, GM for male and GF for females, and two subgroups according to the side examined, R for right and L for left. All tomographic acquisitions were followed by the same protocol and images analysis were made on the same software. Image filters associated with cross-seccional slices, oblique and panoramic reconstruction for the analysis of BMC were used. Analyses of descriptive values and comparisons were made between ANOVA test with a significance of 95%. It was observed that there were 80 cases of BMC (26. 67%), 39 (48. 75%) in male and 41 (51. 25%) in females. There was no difference in measurements compared by sex (p=0.788 male; p=0.140 female) and for the affected side (p=0.365 right, p=0.412 left), although the right side was more frequent (66.67%) in both sexes. Thus, it can be concluded that the incidence of BMC is relevant and should not be overlooked by dentists
23

Avaliação da prevalência de canais mandibulares bífidos em tomografia computadorizada por feixe cônico /

Villaça-Carvalho, Maria Fernanda Lima. January 2012 (has links)
Orientador: Júlio Cézar de Melo Castilho / Banca: Leonardo Marchini / Banca: Rívea Inês Ferreira / Resumo: O canal mandibular pode apresentar diferentes morfologias, em alguns casos, existe a presença de um canal acessório chamado bífido. O objetivo deste estudo foi avaliar a prevalência de canais mandibulares bífidos (CMB) por meio de Tomografia Computadorizada por Feixe Cônico (TCFC). Examinaram-se tomografias de 300 pacientes tanto do sexo masculino quanto do feminino, com idade compreendida entre, 25 a 87 anos, submetidos ao exame para avaliação da mandíbula. Os indivíduos foram divididos em dois grupos de acordo com o sexo, GM para o masculino e GF para o feminino, e dois subgrupos de acordo com o lado examinado, D para o direito e E para o esquerdo. Todas as aquisições tomográficas seguiram um mesmo protocolo de aquisição e a análise das imagens se deu num mesmo software. Foram utilizados filtros de imagens associados aos cortes transversais, oblíquos e reconstrução panorâmica para análise do CMB. Realizaram-se análises descritivas dos valores e comparações entre os fatores pelo teste Anova com significância de 95%. Foi possível observar que os CMB ocorreram em 80 casos (26,67%), destes, 39 (48,75%) no sexo masculino e 41 (51,25%) no feminino, não sendo verificadas diferenças nas mensurações comparadas por sexo (masc p=0,788; fem p=0,140) nem por lado acometido (dir p=0,365; esq p=0,412), apesar do direito ter sido mais frequente (66,67%) em ambos os sexos. Desta forma, pode-se concluir que a prevalência dos CMB é significante e não deve ser negligenciada pelos cirurgiões dentistas / Abstract: The mandibular canal can have different morphologies, in some cases is present a second canal (bifid). The aim of this study was to evaluate the incidence of bifid mandibular canals (BMC) by Cone Beam Computed Tomography (CBCT). Cone beam CT scans of 300 patients, both male and female, aged 25 to 87 years old, who underwent the examination for evaluation of the mandible, were examined. Patients were divided into two groups according to sex, GM for male and GF for females, and two subgroups according to the side examined, R for right and L for left. All tomographic acquisitions were followed by the same protocol and images analysis were made on the same software. Image filters associated with cross-seccional slices, oblique and panoramic reconstruction for the analysis of BMC were used. Analyses of descriptive values and comparisons were made between ANOVA test with a significance of 95%. It was observed that there were 80 cases of BMC (26. 67%), 39 (48. 75%) in male and 41 (51. 25%) in females. There was no difference in measurements compared by sex (p=0.788 male; p=0.140 female) and for the affected side (p=0.365 right, p=0.412 left), although the right side was more frequent (66.67%) in both sexes. Thus, it can be concluded that the incidence of BMC is relevant and should not be overlooked by dentists / Mestre
24

Avaliação in vitro da influência de cargas axiais em próteses parciais fixas implanto-suportadas, por meio da extensometria /

Vasconcellos, Luis Gustavo Oliveira de . January 2008 (has links)
Orientador: Lafayette Nogueira Junior / Banca: Renato Sussumu Nishioka / Banca: Diego Klee de Vasconcellos / Resumo: O objetivo deste estudo foi avaliar in vitro, por meio da extensometria, a influência da aplicação de cargas axiais em próteses parciais fixas de 3 elementos, suportadas por implantes de conexão hexágono interno (HI), variando o tipo de cilindro e o ponto de aplicação de carga. Inicialmente foram inseridos, em disposição linear, três implantes de HI em um bloco de poliuretano. Em seguida, pilares protéticos microunit foram conectados aos implantes com torque de 20Ncm, e sobre estes foram parafusados cilindros usinados de Co-Cr e cilindros plásticos, as quais receberam enceramentos padronizados que foram posteriormente fundidos em liga de Co-Cr (n=5). Quatro extensômetros (SG) foram colados na superfície do bloco, tangenciando os implantes visando mensurar a microdeformação peri-implantar no momento da aplicação das cargas. Cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10Ncm e a seguir foi realizada a aplicação de carga axial de 30kg em 5 pontos pré-determinados. Os dados obtidos na extensometria foram submetidos aos testes estatísticos ANOVA e Tukey (α=5%). Os resultados mostraram diferença estatisticamente significante para o ponto de aplicação de carga (p=0,0001), sendo que o ponto B gerou a menor microdeformação (239,49με) e o ponto D a maior microdeformação (442,77με). Com relação ao tipo de cilindro, não foi observada diferença estatisticamente significante (p=0,748). Concluiu-se que o tipo de cilindro não interferiu na magnitude da microdeformação peri-implantar durante a aplicação de cargas axiais e que a localização da aplicação de carga axial influenciou a magnitude desta microdeformação. / Abstract: The aim of this study was to evaluate in vitro, by means of strain gauge analysis, the influence of aplication of axial loading in three-units fixed partial prostheses, supported by implants with internal hexagon connection (IH), varying the type of cylinders, and the point of load application. Three fixtures IH were inserted in linear arrangement, into a polyurethane block. Microunit abutments were connected to implants with torque of 20Ncm. The framework were fabricated as a one piece casting using plastic burn out components and Co-Cr prefabricated cylinders components (n=5). Four strain gauge were bonded around the microunit abutments on block surface to measure the peri-implant microstrain at the time of application of loads. Each framework was tight on the abutments with torque of 10Ncm and then was made the application of axial load of 30kg in 5 points pre-determined. The data obtained in the strain gauge analysis were submitted to the statistical tests ANOVA and Tukey (α=5%). The results showed a statistically significant difference to the point of application of load (p = 0.0001), whereas the point B has generated the lowest microstrain (239.49 με) and the point D has provided the highest microstrain (442.77 με). Regarding the type of cylinder, statistically significant difference was not observed (p = 0.748). It was concluded that the type of cylinder did not interfere on the magnitude of peri implant microstrain during the application of axial loads and that the location of the application of axial load influenced the magnitude of this microstrain. / Mestre
25

Biocompatilibidade in vivo de implantes de titânio submetidos ao processo biomimético /

Machado, Ana Cristina Posch. January 2008 (has links)
Resumo: Propõe-se neste estudo avaliar a neoformação óssea no interior dos poros e ao redor de implantes porosos de titânio, submetidos ao processo biomimético modificado, inseridos em tíbias de coelhos. Foram confeccionados 180 implantes de titânio puro grau 2, com porosidade controlada, obtidos por meio da metalurgia do pó. Noventa implantes foram pré-tratados com solução de NaOH à 130ºC/1h, submetidos à temperatura de 200ºC/1h e posteriormente imersos em fluido corpóreo simulado modificado por 14 dias. Os implantes foram inseridos em 30 coelhos sendo que cada um recebeu 3 implantes tratados na tíbia esquerda e 3 sem tratamento na tíbia direita. Os animais foram sacrificados em 15, 30 e 45 dias após a cirurgia e os fragmentos das tíbias contendo os implantes foram submetidos à análise histológica, histomorfométrica e teste mecânico de cisalhamento. A análise microestrutural das amostras foi realizada por microscopia eletrônica de varredura (MEV), espectrometria por energia dispersiva de raios X (EDS) e espectroscopia Raman e a avaliação da neoformação óssea por microscopia de luz (MO) e MEV, comparando implantes sem tratamento com aqueles submetidos ao tratamento biomimético. O EDS indicou que a superfície do implante após o tratamento biomimético continha principalmente cálcio (Ca) e fósforo (P) além da presença de titânio. A Espectroscopia Raman do implante de titânio, após o tratamento biomimético, indicou pico característico e de grande magnitude a 960cm-1 devido à formação de uma camada de hidroxiapatita. As imagens ao MO e MEV demonstraram que houve neoformação óssea na interface osso-implante e no interior dos poros, inclusive naqueles mais centrais. Observou-se que a porcentagem média de neoformação óssea nos implantes tratados nos três tempos de sacrifício foi maior do que nos implantes não tratados, sendo observada diferença... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study is to define the coating on porous titanium implants submitted to modified biomimetic process and to evaluate bone neoformation inside the porous and around these implants when inserted in tibiae of rabbits. One hundred and eighty pure titanium implants, fabricated by powder metallurgy, were made. Ninety implants were pretreated with NaOH solution at 130ºC/1h and submitted to the temperature of 200ºC/1h and immersed in modified simulated body fluid for 14 days. The implants were inserted in 30 rabbits; each rabbit received 3 treated implants in the left tibia and 3 untreated implants in the right tibia. The animals were sacrificed after 15, 30, and 45 days of surgery and the tibia fragments containing the implants were submitted to histological and histomorphometric analyses and shear strength test. The microstructure analysis of the samples was performed by scanning electron microscope (SEM), energy dispersive spectrometry (EDS) and Raman spectroscopy; the bone neoformation was evaluated by light microscopy (MO) and SEM comparing only sinterized implants with those submitted to biomimetic treatment. The EDS indicated that the implant surface after biomimetic treatment contained mainly calcium (Ca) and phosphorous (P) in addition to the presence of titanium. The Raman spectroscopy of the titanium implant, after biomimetic treatment, indicated the formation of a hydroxyapatite layer due to the characteristic peak and of great magnitude at 960cm-1. The MO and SEM images showed bone neoformation on the interface bone-implant and inside the porous, including the most internal ones. It was observed that the mean percentage of bone neoformation in the treated implants for the three sacrifice periods were higher than the untreated implants, statistically significant for the 15-day period. The mechanical test showed that the coated implants... (Complete abstract, click electronic access below) / Orientador: Yasmin Rodarte Carvalho / Coorientador: Marize Varella de Oliveira / Banca: Yasmin Rodarte Carvalho / Banca: Marize Varella de Oliveira / Banca: Luana Marotta Reis de Vasconcellos / Banca: Paulo Tambasco de Oliveira / Banca: Carlos Alberto Alves Cairo / Banca: Monica Calixto Andrade / Doutor
26

Avaliação, por extensometria, da deformação superficial no substrato de retenção dos implantes gerada por próteses fixas implanto suportadas em função do cantilever /

Mesquita, Alfredo Mikail Melo. January 2008 (has links)
Orientador: Estevão Tomomitsu Kimpara / Banca: Estevão Tomomitsu Kimpara / Banca: Rander Pereira Avelar / Banca: Eduardo Miyashita / Banca: Rubens Nisie Tango / Banca: Marco Antonio Bottino / Resumo: O objetivo deste estudo foi avaliar, por extensometria, da deformação superficial ao redor de implantes em função do comprimento do cantilever de próteses implanto-suportadas por 2 ou 3 implantes. Para tanto, foram posicionados, paralelos entre si, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75mm de diâmetro por 11,5mm de comprimento, a uma distância entre eles de 8mm, de centro a centro, em um modelo experimental de poliuretano com dimensões de 10x7x2cm. Pilares protéticos tipo Multi-Unit, com 3,0mm de altura de cinta metálica foram instalados sobre os implantes. Com auxílio de um dispositivo em alumínio, foram confeccionados 16 padrões de fundição em resina acrílica; 8 com 2 implantes; e 8 com 3 implantes sobre cilindros calcináveis. Em seguida os padrões foram fundidos em liga de cobaltocromo pela técnica convencional à maçarico. Três extensômetros lineares (strain gauges) foram colados na superfície superior do bloco experimental de poliuretano tangenciando a plataforma dos implantes. Cargas de 10kg foram exercidas na barra em local eqüidistante entre os dois implantes mais próximos do cantilever, e no cantilever a uma distância de 5, 10, 15, 20 e 25mm, com auxílio de um dispositivo desenvolvido para esta finalidade. Os extensômetros conectados a um aparelho condicionador de sinais elétricos além de alimentar a corrente elétrica, amplificou e converteu o sinal gerado de analógico para digital. Para cada local de carga foram feitas três medições. Os dados obtidos foram submetidos à Análise de Variância (ANOVA) de 3 fatores, e ao teste de Tukey (p<0,05). Como conclusão do tratamento dos dados obtidos em microdeformação (με): não houve diferença da utilização de dois ou três implantes na distribuição de carga no substrato de retenção dos implantes; quanto maior a extensão do cantilever, maiores deformações foram geradas ao redor dos implantes. / Abstract: The aim of this study was to evaluate, using strain gauge, the load distribution surround the implants according the cantilever length of implant-supported prosthesis by two or three implants. Sixteen polyurethane models were obtained from an acrylic block (10 x 7 x 2 cm). In half of these models two cylindrical implants with external hexagon were fixed (diameter: 3.75 mm; length: 11.5 mm) and positioned 8 mm between their centers in each model. On the other half, three parallels implants were fixed in the same conditions. The Multi-Unit abutments with 3 mm of metallic neck were connected to the implants. With the assistance of an aluminum device, it was manufacture sixteen acrylic resin patterns over the cast cylinders: eight with two implant and eight three implants. After, patterns were casted in cobalt-chromium alloy, using the casting conventional technique. Three strain gauges were positioned on the upper surface of the experimental polyurethane model around the implants. With an assistance of a device, the metallic bars were loaded with 10 Kg between the two implants near to the cantilever and 5, 10, 15, 2 and 25 mm along the cantilever length. The strain-gauge was connected to a multichannel bridge amplifier to form one leg of the bridge. The computer was interfaced with bridge amplifier to register output signs of polyurethane strain. Each point of loading was measured three times. The data were submitted to ANOVA (three-way) and Tukey test (p<0.05). The cantilever length affected negatively the load distribution around the implants around the implants (p<0.05). Such as conclusion t from the treatment of the data obtained (με): there wasn't difference between the using of two or three implants on the stress distribution on the substrate of implants retention; how longer is the cantilever, higher stress around implants were generated. / Doutor
27

Avaliação da resposta tecidual frente aos cimentos MTA e MBPc. Análise microscópica de implantes realizados em alvéolos dentários de ratos / EVALUATION OF THE TISSUE RESPONSE TO MTA AND MBPC. MICROSCOPIC ANALISIS OF IMPLANTS IN ALVEOLAR BONE OF RATS.

Luciano Tavares Angelo Cintra 25 February 2005 (has links)
Este trabalho teve como objetivo avaliar quantitativa e qualitativamente a resposta inflamatória e a formação óssea frente ao implante de tubos de polietileno contendo o cimento experimental, MBPc, que contém o hidróxido de cálcio, desenvolvido pelos Profs. MORAES e BERBERT da disciplina de Endodontia da Faculdade de Odontologia de Bauru – USP, comparando-o ao cimento ProRoot MTA. Foram utilizados 48 ratos, divididos em três grupos. No grupo I, foram introduzidos no alvéolo dentário pós-extração tubos de polietileno vazios que serviram de controle para os grupos experimentais. No grupo II foram implantados tubos contendo o cimento ProRoot MTA e no grupo III o cimento experimental MBPc. Após 7, 15 e 30 dias do implante os animais foram mortos e as hemimaxilas direitas que continham os alvéolos e os tubos implantados foram removidas e processadas em laboratório para a análise em microscopia de luz. Os resultados demonstraram que ambos materiais têm comportamento biológico semelhante. Os valores obtidos por meio da avaliação por escores, quando submetidos ao teste de Mann-Whitney, cujo nível de significância adotado foi de 5%, não apresentaram diferenças estatisticamente significante entre os materiais. / The aim of this work was to evaluate in a quantitative and qualitative manner the inflammatory response and the bone formation after the implantation of tubes filled with the experimental sealer, MBPc, which has calcium hidroxide and was developed by Professors Moraes and Berbert (Endodontic Department – Bauru Dentistry College – USP) comparatively to ProRoot MTA. It was used 48 rats, which were divided in three groups. In the group I, empty polietilene tubes were inserted into the alveolar bone imediatelly after extraction, which were used as control. In the group II and group III, polietilene tubes filled with ProRoot MTA and MBPc were implanted respectivelly. After 7, 15 and 30 days after the implantation, the animals were sacrificed and the right hemi-maxilas, which had the alveolar bone with the tubes implanted, were removed and prepared for ligth microscopic analisis. The results showed that both materials had similar biological response. The scores obtained and submitted to Mann-Whitney statistical test (5%) did not showed significant differences between the materials.
28

Avaliação retrospectiva de oito anos dos procedimentos implantodonticos associados ou não a procedimentos reconstrutivos realizados na area de cirurgia buco-maxilo-facial da Faculdade de Odontologia de Piracicaba

Stabile, Glaykon Alex Vitti 22 February 2006 (has links)
Orientador: Renato Mazzonetto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T13:20:28Z (GMT). No. of bitstreams: 1 Stabile_GlaykonAlexVitti_M.pdf: 2525293 bytes, checksum: aadb026ad284ab6fa320ca3a2895af56 (MD5) Previous issue date: 2006 / Resumo: O objetivo deste estudo foi realizar por meio de um levantamento retrospectivo de oito anos um delineamento do perfil da implantodontia dentro da Área de Cirurgia Buco-Maxilo-Facial da Faculdade de Odontologia de Piracicaba (FOP-Unicamp). Foram revisados ao todo 1422 prontuários cujos pacientes deveriam ser submetidos a procedimentos reabilitadores através da instalação de implantes dentários endósseos osseointegráveis. Os pacientes em questão foram caracterizados quanto à cor, gênero, idade, história médica pregressa, vícios e queixa principal. Os procedimentos realizados foram divididos em: procedimentos reconstrutivos (distração osteogênica, lateralização do nervo alveolar inferior, enxertos ósseos autógenos, enxertos ósseos heterógenos e levantamento de seio maxilar), sendo qualificados quanto ao momento de execução (previamente à instalação de implantes, de modo concomitante, ou ainda posteriormente a estes), região dos maxilares que foram reconstruídas por meio destes procedimentos e materiais utilizados, ou ainda procedimentos implantodônticos (número, dimensões, propriedades e região de instalação dos implantes dentários). Do universo analisado 732 prontuários obedeceram os critérios de inclusão. Desses, 65,16% eram do gênero feminino, com prevalência de pacientes na quinta década de vida; 21,31% relataram alterações sistêmicas e 19,26% dos pacientes utilizavam medicação de uso contínuo. O motivo que mais levou os pacientes a buscar um tratamento reabilitador através de implantes dentários foi a ausência dentária em 33,33% dos casos. Procedimentos reconstrutivos foram empregados em 38,52% dos pacientes, sendo esses: 15 distrações osteogênicas; 6 lateralizações do nervo alveolar inferior, 256 enxertos ósseos autógenos, 31 enxertos ósseos heterógenos e 72 pacientes receberam elevações de seio maxilar. Foram instalados 1649 implantes, perfazendo uma média de 2,25 implantes por paciente sendo a região anterior de maxila a mais reabilitada com 29,29% dos implantes instalados. Ao todo 62 implantes (3,75%) foram classificados como perdas primárias, sendo que a proporção de implantes perdidos em áreas reconstruídas ou em osso nativo foi semelhante (3,86% e 3,72% respectivamente). Como conclusão observamos que o perfil da população atendida no serviço em questão é principalmente de indivíduos da cor branca, gênero feminino e idade média de 42 anos, com queixa de ausência de um ou mais elementos dentários. Os procedimentos reconstrutivos foram em sua maioria enxertos ósseos autógenos de sítios doadores intrabucais realizados previamente à instalação de implantes dentários e que a taxa de perdas primárias entre implantes instalados em osso reconstruído e em osso nativo é bastante semelhante / Abstract: The aim of this study was to perform, through an eight-year retrospective survey, the identification of the characteristics of implantology in the Oral and Maxillofacial Surgery area of Piracicaba Dental School (FOP ¿ Unicamp). A total number of 1422 files of patients who should receive endosseous dental implants were reviewed. Patients were characterized as to color, gender, previous medical history, addictions and main complaint. The performed procedures were divided into: reconstructive procedures (distraction osteogenesis, inferior alveolar nerve lateralization, autogenous bone grafts, heterogenous bone grafts and maxillary sinus lift), according to the time of reconstruction (previously to implant installation, in the same surgical time or after implant placement), reconstructed regions and used materials, or implantodontic procedures (number, dimensions, properties and implant placement regions). From the analyzed data, 732 files met the inclusion criteria. Of the included files, 65.15% were female patients, and the fifth decade of age was the most prevalent; 21.31% reported systemic alterations, and 19.26% of the patients were taking continuous use medications. The most frequent reason for seeking rehabilitation with dental implants was dental absence (33.33% of the cases). Reconstructive procedures were performed in 38.52% of the patients: 15 cases of distraction osteogenesis; 6 lateralizations of the inferior alveolar nerve; 256 autogenous bone grafts; 31 heterogenous bone grafts and 72 patients who received maxillary sinus lifts. A total number of 1649 implants were placed, with a mean of 2.25 implants per patient, and the anterior maxilla was the most frequently rehabilitated region, with 29.29% of the implants. Early loss affected 62 implants (3.75%), and the percentage of lost implants in reconstructed or native bone areas was similar (3.86% and 3.72% respectively). As a conclusion, it was observed that the profile of the population treated in the service is manly female, white patients, with a mean age of 42 years-old and with a complaint of absence of one or more teeth. The most frequent reconstructive procedures were autogenous bone grafts from intraoral donor sites performed prior to the installation of dental implants, and the early loss in reconstructed and native bone regions is very similar / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
29

Avaliação da localização do canal mandibular por meios de exames tomografico (linear, Pluridirecional e computadorizados de alta resolução) em comparação com a anatomia ossea topografica

Faria, Marcelo Daniel Brito 10 April 2000 (has links)
Orientador: Agenor Montebello Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T05:42:06Z (GMT). No. of bitstreams: 1 Faria_MarceloDanielBrito_D.pdf: 2753888 bytes, checksum: f51d5a94ef8d365d8baf63fde380e7aa (MD5) Previous issue date: 2000 / Resumo: Este estudo teve por objetivo avaliar a localização do canal mandibular em imagens obtidas de crânios secos por meio de exames tomográficos lineares, pluridirecionais e computadorizados de alta resolução em relação com a anatomia óssea topográfica. Foram utilizadas 1I mandíbulas secas de humanos pertencentes a Área de Radiologia da Faculdade de Odontologia de Piracicaba FOP-UNICAMP que possuiam extremo livre posterior e reabsorção óssea alveolar moderada tipo B segundo LINDH, C et al ( 1995 ) . Foram analizados 22 (Vinte e dois) Canais mandibulares Inferiores ( CM) e 88 ( Oitenta e oito) medidas foram realizadas. Em cada mandíbula foram feitas 04 ( medidas) : V1 - que correspondeu a distância do rebordo alveolar remanescente ao centro do CM ; V2 - distância da cortical externa da base mandibular ao centro do CM ; H1 distância do centro do CM à cortical externa lingual; H2 - distância do centro do CM à cortical externa vestibular. Foram confeccionados guias radiográficos nas regiões de interesse antes da exposição, sendo esferas metálicas de 3,0 mm de diâmetro para os exames convencionais e guias com guta percha para as tomografias computadorizadas de alta resolução. Os aparelhos utilizados foram ORTHOPHOS CD PLUS da SIRONA com os programas pl9 e p20 de cortes pluridirecionais transversais com kV de 60 e 09 mA e espessura do corte de 3,0mm, o tomógrafo Linear Denar Quint Sectograph com cefalostato e kV 52 e mA 50 e espessura dos cortes de 2,5mm e intervalo entre os cortes de 3,0mm. O tomógrafo computadorizado de alta resolução foi o SOMA TOM HiQ-S da Siemens com cortes coronais diretos que foi baseado no protocólo de FARIA CR-IMP ( 1999). Após obtidas as imagens foram realizadas as medidas com paquímetro MITUTOYO e comparadas com as peças seccionadas obtidas e nossos resultados após aplicado análise de variância e teste de Tuckey foram para a tomografia linear de: A distância V1- 13,19mm ; V2 - 8,73mm ;H1 - 5,11mm e H2 -6,44mm .Tomografia Computadorizada de : V1 11,12mm ; V2 - 7,55mm ; H1 - 5,22mm e H2 - 6,22mm. Pluridirecional de : VI - I5,85mm ; V2 - 1O,17mm ; HI6,45mm e H2 - 8,l0mm. E os dados anatômicos de V1 - 13,O4mm ; V2 - 8,7mm ; HI- 5,36mm e H2 - 6,18mm .Baseado nos resultados das medidas o canal mandibular à 3,5cm posterior ao forame mentoniano apresentou-se mais próximo da cortical lingual e a técnica que apresentou maior precisão nas medidas quando comparadas com a anatomia óssea topográfica foi a Tomografia Linear, pois esta não apresentou diferença estatisticamente significante. Já a tomografia computadorizada demonstrou dados com uma discrepância mínima em relação a anatomia óssea topográfica apresentando diferença estatísticamente significante nas medidas verticais e a técnica pluridirecional apresentou diferença estatísticamente tanto nas medidas verticais como nas horizontais. Logo nosso estudo conclui que a técnica tomográfica mais apurada no que diz respeito as dimensões verticais e horizontais para o planejamento de implantes osteointegráveis foi a Tomografia Linear / Abstract: The aim of this study was compare the vertical and horizontal dimensions in images obtained from dried skulls by means of three types of tomographic exams: linear; transversal pleuridirectional panoramic and computerized high resolution with bone topographic anatomy. The selection of a precise radiographic method proved to be of great importance in the planning of osteointegradable implants. Such approach would imply the reduction of traumatic lesions to noble structures of the maxillomandibular complex during surgery. With this purpose, eleven dried mandibles ITom the Radiology Department of the Dentistry University of Piracicaba.( FOP, Unicamp) were analyzed. All of these presented an edentuous posterior and type B alveolar bone reabsorption according to LINDH, C et al.( 1995 ). Twenty two inferior alveolar canals ( CAI ) were selected and 88 measurements were accomplished. Four measurements were made on each mandible: V1,which corresponded the distance of the alveolar ridge to the center of the CAI; V2, the distance of the external cortical of the mandibular base to the center of the CAI; RI, the distance of the center of the CAI to the external lingual cortical; m, the distance from the center of the CAI to the external bucal cortical. Radiographic guides were built at regions of interest before the exposition of metallic step ( 4mm diameter) for conventional exams. Also, gutta percha guides were introduced for high resolution computerized tomography making possible the elimination of artifacts. The equipment used were the SIRONA, Orthophos CD plus, with pI9 and p20 programs of transversal pleuridirectional slices (60kV and 09 mA and slice thickness of 3,0 mm), the Linear Denar Quint Sectograph tomographer with cefalostat ( 52kV and 50 mA and slice thickness of 2,5 mm and intervals between slices of 3,0mm) and the Siemens, SOMATOM HiQ-S computerized high resolution tomographer, opting for direct coronal slices that were based on the FARIA CR-IMP ( 1999 ) protoco1. After images were obtained, measurements were made with a MITUTOYO paquimeter and compared to the sliced mandibles. The mean results of the measurements were later applied to varience analysis and Tuckey test. The following results were obtained for linear tomography: VI - 13,19 mm; V2 - 8,73 mm; Hl 5,11mm; H2 - 6,44 mm. As for computed tomography: V1- 11,12 mm; V2 - 7,55 mm; H1 - 5,22 mm; H2 - 6,22 mm; while pleuridirectional tomography: V1- 15,85 mm; V2 - 10,17 mm; H1 - 6,45 mm; H2 - 8,10 mm. Further more, the anatomic measurements: VI - 13,04 mm; V2 - 8,70 mm; H1 - 5,36 mm; H2 - 6, 18mm. These results have not proved a significant statistical difference between the mean results of measurements in linear tomography exams. However, the exams computed tomography, once these presented a minimal discrepancy with a significant statistical different in the vertical mensurement when compared to the real anatomic measurements and pluridirectional presented significant statistical difference in alI of the mensurements Fina1ly, this subject conc1udes that linear tomography was more accurate for dental osteointegradable planning / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
30

Analise histologica e histomorfometrica do reparo osseo perimplantar em cães submetidos a instalação de implantes endosseos com um modelo de carga precoce em dois diferentes desenhos de implantes / Histological and histomorphometric analysis of perimplant osseous repair in dogs submitted to endosseous implant installation with early load model in two different implant design

Olate Morales, Sergio Adrian 02 December 2009 (has links)
Orientador: Jose Ricardo de Albergaria-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:32:19Z (GMT). No. of bitstreams: 1 OlateMorales_SergioAdrian_M.pdf: 2518502 bytes, checksum: 379ec7fb825eca639d7e7c3aa4e052a8 (MD5) Previous issue date: 2009 / Resumo: Diferentes protocolos para a reabilitação com prótese implanto assistida têm sido reportados. Deles, é possível que a carga imediata em implantes unitários sejam um dos mais controversos. O objetivo deste estudo foi estabelecer quantitativamente as características de reparo ósseo em implantes submetidos a um modelo de carga precoce. Foi desenvolvido um modelo experimental em cães para a avaliação de dois protocolos de instalação de implantes dentais com dois desenhos diferentes. Foi realizada a exodontia dos pré-molares bilaterais mandibulares dos animais e após de três meses foi realizada a instalação de dois implantes bilateriais. No implante mesial foi realizada a instalação do parafuso cicatrizador de 7 mm (modelo de carga imediata unitária sem contato oclusal) e no implante distal foi instalado o parafuso cobertor (técnica de implante submerso). Cada hemimandíbula recebeu um implante cilíndrico (Neodent Titamax CM®) e um implante cônico (Conexão Conect Ar®) com seu parafuso cicatrizador. Inicialmente os primariamente foram avaliados com microscopia eletrônica de varredura. Os sacrifícios dos animais foram após de três e seis semanas. Os blocos foram descalcificados e processados para análise com histológica descritiva e histomorfométrica. Foi aplicado o teste estatístico t teste para variáveis independentes com nível de significância de 5%. De forma geral, os implantes apresentaram maior formação óssea no nível cervical e menor no nível apical. Os resultados demonstram também maior formação óssea em implantes com o modelo de carga precoce que em aqueles sem carga, com ausência de diferença estatística. Por outra parte, os implantes cônicos apresentaram maior formação óssea que os cilíndricos, também sem significância estatística. Concluiu-se que os implantes com instalação do parafuso cicatrizador, como modelo de restauração imediata sem contato oclusal, apresenta maior quantidade óssea nos vales quando comparados aos implantes não submetidos a carga / Abstract: Several treatment types using prosthesis over implants have been reported, being the singles immediate loading therapy with more controversy. The meaning of the present study is established the characteristics of bone repair in dental implant submitted to immediate loading. It was performed a experimental model using dogs to value two different installations protocols of dental implants. It was done the extraction of the bilateral premolars of the jaw, installing the dental implants after 3 months of healing. The anterior implant was submitted to healing screw install of 7 mm (unitary immediate load model without oclusal contact) and the posterior ones were covered with cove screrw (immerse implant technique). Each hemi-jaw presented one cylindrical (Neodent Titamax CM®) or conical (Conexão Conect Ar®) with with anterior or posterior position, that was evaluated with scanning electron microscopy. The sacrifices were performed on three and six months. The specimens were decalcified and processed to begging its histological evaluation using descriptive and histomorphometric analyses. The statistical test T test was performed using significance index of 5%. In general, dental implants showed more bone formation on cervical region and less on apical area. The results demonstrated more bone formation on the immediate loading types, with no statistical significance. The conical ones presented more bone formation that cylindrical, but without statistical significance. This way it is possible to conclude that implants with immediate installation of healing screw, how immediately load model without oclusal contact (immediately restauration), have more osseous presence when compared to non load implant / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica

Page generated in 0.4841 seconds