• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 417
  • 7
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 428
  • 258
  • 235
  • 129
  • 125
  • 98
  • 84
  • 83
  • 80
  • 78
  • 64
  • 51
  • 49
  • 45
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Desenvolvimento de métodos analíticos ambientalmente mais amigáveis para a quantificação de bumetanida em medicamentos e urina

Pollo, Fernanda [UNESP] 02 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-02Bitstream added on 2014-06-13T19:58:57Z : No. of bitstreams: 1 pollo_f_me_araiq.pdf: 1087954 bytes, checksum: 776ba6eca2d4135de3d73ba6774b93ab (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho foram desenvolvidos três métodos ambientalmente amigáveis para quantificar bumetanida. O primeiro método desenvolvido foi o de espectroscopia de reflectância difusa utilizando spot test. O método é baseado na reação entre bumetanida e o reagente cromogênico p-dimetilaminocinamaldeído (p-DAC - 3,4 x 10-2 mol L-1) em meio ácido (HCl - 2,1 x 10-1 mol L-1) sobre a superfície de um papel de filtro, produzindo um complexo colorido (?máx = 525 nm) estável. Para a reação apenas 20 æL de cada solução foi utilizada, sendo um procedimento limpo, pois gera pouco resíduo ao meio ambiente. A faixa de trabalho estudada variou entre 1,37 x 10-4 a 1,37 x 10-3 mol L-1 (50-500 ppm). Os limites de detecção (LOD) e de quantificação (LOQ) calculados foram 3,98 x 10-5 e 1,33 x 10-4 mol L-1 respectivamente. O segundo método foi o de análise por injeção em fluxo com detecção espectrofotométrica utilizando o sistema de adição de reagente por confluência. O método também se baseia na reação entre bumetanida e p-DAC supracitada, com o diferencial de usar de meio micelar (Dodecil Sulfato de Sódio (SDS)), o que acarretou um aumento na sensibilidade de cerca de 4,75 vezes. O reagente (p-DAC 5,6 x 10-3 mol L-1 preparado em HCl 6,2 x 10-2 mol L-1) é adicionado no percurso analítico através de uma confluência, onde reage com 918 æL de solução contendo o analito em uma bobina reacionária de 163 cm . Ambas as soluções foram transportadas por uma solução de SDS 8,0 x 10-3 mol L-1. A faixa de trabalho foi de 1,37 x 10-6 a 2,77 x 10-5 mol L-1 (0,5-10 ppm). Os limites de detecção (LOD) e de quantificação (LOQ) calculados foram 3,07 x 10-7 e 1,03 x 10-6 mol L-1 respectivamente. A freqüência analítica obtida foi de 69 análises por hora. O terceiro e último método desenvolvido foi o de análise por injeção... / In this work were developed three environmentally friendly analytical methods for quantification of bumetanide. The first method developed was diffuse reflectance spectroscopy using spot test analysis. The method is based on the reaction between bumetanide and colored reagent p-dimethylaminocinnamaldeyde (p-DAC - 3.4 x 10-2 mol L-1) in acid medium (HCl - 2.1 x 10-1 mol L-1) on the surface of filter paper, yielding a stable colored product (? = 525 nm). For the reaction only 20 æL of reagent was applied, it's a clear procedure, yielding a little quantity of residues. The linear range was 1.37 x 10-4 to 1.37 x 10-3 mol L-1 (50 - 500 æg mL-1). The limits of detection (LOD) and quantification (LOQ) estimated were 3.98 x 10-5 and 1.33 x 10-4 mol L-1 respectively. The second method was flow injection analysis using spectrophotometric determination using the system with continuous reagent addition. The method is based on the reaction between bumetanide and p-DAC above mentionated, but using a micellar medium (Sodium Dodecyl Sulfate (SDS)), allowing up to 4.75 fold increase in sensitivity. The reagent (p-DAC 5.6 x 10-3 mol L-1 in HCl 6.2 x 10-2 mol L-1) is added on the analytical course using a confluence, where it reacts with 918 æL of sample solution in reaction coil of 163 cm. The solutions were carried by a SDS solution 8.0 x 10-3 mol L-1 The linear range was 1.37 x 10-6 to 2.77 x 10-5 mol L-1 (0.5 -10 æg mL-1). The limits of detection LOD) and quantification (LOQ) estimated were 3.07 x 10-7 e 1.03 x 10-6 mol L-1 respectively. The average sample rate of 69 determinations per hour. The last method developed was flow injection analysis exploiting merging zones. In this case the reagent isn't added continously it has fixed volume on the reaction... (Complete abstract, click electronic access below)
52

Desenvolvimento de um método simples, limpo e rápido para a determinação de fluoroquinolonas em formulações farmacêuticas /

Primani, Lucas. January 2014 (has links)
Orientador: Helena Redigolo Pezza / Co-orientador: Leonardo Pezza / Banca: José Anchieta Gomes Neto / Banca: Enelton Fagnani / Resumo: No presente trabalho foi desenvolvido um método limpo, simples, rápido e de baixo custo para a determinação de antibióticos da classe das fluoroquinolonas como a norfloxacina (NOR), a enrofloxacina (ENR), a ciprofloxacina (CIP) e a levofloxacina (LEV) em formulações farmacêuticas através de um sistema de análise por injeção em fluxo (FIA) utilizando multibombas e detecção espectrofotométrica. A metodologia é baseada na reação, em meio micelar (exceto para LEV), desses princípios ativos com n-bromossuccinimida como reagente cromogênico. Os produtos formados apresentaram coloração amarelada com absorbância máxima em 410nm para NOR, CIP e ENR e 435nm para LEV. Os limites de detecção foram de 0,29; 0,28; 0,29 e 0,35 g mL-1 para NOR, CIP, LEV e ENR, respectivamente. O método proposto foi aplicado com sucesso na determinação destes fármacos em diferentes amostras de formulações farmacêuticas. Os resultados obtidos apresentaram muito boa concordância com aqueles obtidos pelo método de referência. / Abstract: In this present work was developed a clean, simple, fast and inexpensive method for determination of fluoroquinolones antibiotics class such as norfloxacin (NOR), enrofloxacin (ENR), criprofloxacin (CIP) and levofloxacin (LEV) in pharmaceutical formulations through a system of flow injection analysis (FIA) using the multi-pumping and spectrophotometric detection. The method is based on reactions in micellar medium (except LEV) these active ingredients with n-bromosuccinimide as chromogenic reagent. The products formed showed yellow colored product with maximum absorbance at 410nm for NOR, CIP and ENR, and 435 nm for LEV. The detection limits were 0,29; 0,28; 0,29 e 0,35 g mL-1 para NOR, CIP, LEV and ENR, respectively. The proposed method was successfully applied to the determination of these drugs in different samples of pharmaceutical formulations. The results agreed very well with those obtained by the reference method. / Mestre
53

Influência dos parâmetros de processamento por injeção na correlação estrutura, propriedades e características geométricas do polipropileno

Linck, Cristiano January 2016 (has links)
A injeção de termoplásticos é um processo bastante abrangente e visa a produção seriada de peças. A variabilidade produtiva desse processo pode gerar perdas industriais indesejáveis que poderão impactar sobre os preços dos produtos ou aumentar o descarte de peças pelo incorreto funcionamento de seus componentes. Sabe-se que as tolerâncias de projeto delimitam essa variabilidade, então, se há uma faixa permitida de variabilidade como ela pode ser controlada? Este questionamento levou ao desenvolvimento deste trabalho, que objetiva correlacionar os parâmetros de processamento de velocidade de injeção e temperatura de processamento com propriedades físicas, mecânicas e morfológicas do Polipropileno (PP). O GD&T (Geometrical Dimensioning and Tolerancing) delimita a faixa de variação aceitável da geometria das peças e foi verificado por meio da variação de planeza e circularidade. Além disso, a variação de massa e de colorimetria, de densidade e grau de cristalinidade, a resistência ao impacto e dureza e o índice de fluidez do fundido balizaram este estudo. Resultados mostram que a variação da velocidade de injeção possui influência positiva na variação de planeza, circularidade e massa para temperaturas de processamento mais baixas, enquanto para temperaturas de processamento mais altas, ela tem influência negativa, aumentando os erros As velocidades de injeção não apresentaram mudanças significativas da densidade e do grau de cristalinidade, porém, quanto maior a temperatura de processamento, maior é a densidade e, consequentemente, maior é o grau de cristalinidade. A cor da peça é influenciada por ambos os parâmetros analisados e a resistência ao impacto é influenciada pela velocidade de injeção, enquanto a dureza possui influência direta do grau de cristalinidade e, consequentemente, da temperatura de processamento, que também possui influência significativa sobre o índice de fluidez. Assim, conhecendo a influência dos parâmetros de processamento na moldagem por injeção do PP, é possível combinar melhores propriedades físicas, mecânicas e reológicas, com menor custo e menores tempos de produção e de tomada de decisões. / The injection molding of thermoplastics is a very comprehensive process and aims to mass production parts. The production variability of this process can lead to undesirable industrial losses may impact on the prices of products or increase the disposal of parts by the malfunction of its components. The design tolerances delimit this variability, so if there is a permitted range of variability as it can be controlled? This question led to the development of this work aimed at correlating the injection speed processing parameters and processing temperature with physical, mechanical and morphological properties of Polypropylene (PP). The GD&T (Geometrical Dimensioning and Tolerancing) delimits the acceptable range of variation of the geometry of the parts and has been verified by the change in flatness and circularity, furthermore, the weight variation and colorimetry, density and degree of crystallinity, resistance to impact and hardness and melt flow index Results show that variation in the injection speed rate has a positive influence on the variation of flatness, circularity and mass to lower processing temperatures, while for higher processing temperatures it has negative influence increasing the errors. The injection speed rate had no significant changes of density and crystallinity, but the higher processing temperature increases the density and the degree of crystallinity too. The color of pieces is influenced by both the parameters analyzed and the impact resistance is affected by injection speed rate, while the hardness has a direct influence on the degree of crystallinity and hence the processing temperature, also has a significant influence on the melt flow index. Thus, knowing the influence of processing parameters in injection molding of PP is possible to combine the best physical, mechanical and rheological properties, with less cost and less time production and decision-making.
54

Obtenção de ligas ferro-níquel através da metalurgia do pó e moldagem de pós por injeção para aplicações magnéticas

Villanova, Rodrigo Lupinacci January 1998 (has links)
O objetivo deste trabalho foi o estudo da obtenção de ligas magneticamente macias de ferro-níquel, pelos processo de metalurgia do pó e moldagem de pós por injeção. No processo de Metalurgia do pó foi preparada uma liga Fe-Ni com teor de 50% em peso de níquel, a partir dos pós elementares de cada componente. Foi avaliado o efeito de parâmetros do processo (pressão de compactação e temperatura de sinterização) na resistividade e nas propriedades magnéticas dos corpos de prova compactados, além de análises dimensionais, de densidades obtidas e micrografias. Os resultados de resistividade obtidos mostraram-se abaixo dos valores indicados pela literatura, e houve muitas variações dimensionais. Quanto às propriedades magnéticas, a indução máxima e a permeabilidade máxima tiveram valores baixos, enquanto que a coercitividade e as perdas magnéticas apresentaram valores muito altos, se comparados à literatura. Na etapa de moldagem de pós por injeção foi preparada uma carga de injeção a partir de pós elementares de Fe e Ni (também na proporção 1:1, em peso) e um sistema de ligantes a base de parafina, cera de carnaúba e polietileno de baixa densidade. Foi avaliada basicamente a etapa de extração do ligante, que foi real izada de cinco maneiras distintas. Os valores de densidade das peças sinterizadas foram comparados com aqueles obtidos pela metalurgia do pó convencional. Os resultados mostraram que as densidades obtidas ficaram muito aquém do esperado e, com a carga preparada, apenas uma das rotas de extração utilizadas mostrou-se satisfatória. As principais conclusões obtidas neste trabalho mostram que na etapa de Metalurgia do Pó houve muita variação nos valores, evidenciando um processo de mistura e sinterização insatisfatórios, enquanto que na etapa de Moldagem de Pós por Injeção pode-se concluir que a carga preparada apresentou baixo teor de pó, dificultando portanto a etapa de extração dos ligantes e resultando em peças com baixa densidade. / The aim of this work was the study of iron-nickel soft magnetic alloys, obtained via powder metallurgy (P/M) and metal injection moulding (MIM) processes. In the P/M step, an Fe-Ni alloy with 50% wt% was prepared, from elemental powders of each component. The effect of process parameters, such as compaction pressure and sintering temperature, on resistivity and magnetic properties of the compacted samples were evaluated. Dimensional, densities and micrographical analysis were also performed. The resistivity values were below of those indicated by the literature, and there were large dimensional variation. Compared to the literature, maximum induction and permeability are low, and the coercitivity and magnetic losses are very high. In the MIM step, a base feedstock was prepared. The powders were Fe and Ni, in the same ratio used in the previous step. The binder system was composed basicaly by paraffin wax, carnauba wax and low density polyethilene. The debinding step was evaluated; it was carried out in five different ways. The sintered densities of the samples were compared with those obtained via conventional powder metallurgy. The results show that the densities are below those obtained in the P/M step, and only one of the debinding routes was suitable for the prepared feedstock. The main conclusions of this work show that in the P/M step there was large values variation, evidencing unsatisfactory mixture and sintering processes, while in the MIM step it can be concluded that the prepared feedstock had low powder content, making the debinding step hard to carry out, and resulting in low-density parts.
55

Dois casos de interesse em movimento de carga espacial / Motion of spatial charge: two interesting situations

Raffaele Amazonas Novellino 20 June 1983 (has links)
Este trabalho apresenta dois problemas distintos. No primeiro, obteve-se a característica da corrente em função da voltagem em um dielétrico sob radiação, supondo-se que só um portador seja móvel, que recombinação e injeção da carga móvel através de um eletrodo. Na interface eletrodo-dielétrico foi imposta a condição de densidade de carga constante. No outro problema foi feita uma generalização do problema transiente clássico estudado por Many e Rakavy, usando a mesma condição anterior de densidade de carga constante no eletrodo injetor. Obteve-se soluções analíticas durante o 1º tempo de trânsito e de desenvolveu soluções por computador até o 3º tempo de trânsito. As oscilações amortecidas da corrente em torno do valor estacionário, também merece alguma atenção / Two distinct problems are treated here. In the first one, the relation between current and voltage in a dielectric under radiation is obtained, assuming only carrier to be mobile, recombination and injection of the mobile charge from the electrode. We have chosen for this last boundary condition a constant charge density at the electrode-dielectric interface. The second problem treated is a generalization of the classic transcient problem studied by Many-Rakavy, using the constant charge density boundary condition. Analytic solutions were obtained during the first transit time and computed ones for larger times. Some attention was given to the damped current oscillations approaching the steady state value
56

Estudos das propriedades elétricas de diodos poliméricos com eletrodo injetor à base de óxido de zinco / Studies of Electrical Properties of polymeric diodes with injector eletrode based on zinc oxide.

Edivaldo Leal Queiroz 15 January 2009 (has links)
A presente tese de doutorado apresenta um estudo comparativo das características elétricas de dispositivos emissores de luz poliméricos (PLEDs) confeccionados com óxido de índio dopado com zinco (IZO) como eletrodo transparente alternativamente ao ITO comumente usado em dispositivos poliméricos. As propriedades elétricas de filmes de IZO depositados a frio foram obtidas através da técnica de impedanciometria. Descrevemos detalhadamente todo o processo de fabricação dos dispositivos, com os respectivos eletrodos, em estrutura simples ou contendo uma camada adicional de PEDOT. Dois polímeros luminescentes foram utilizados como camada ativa em nossos dispositivos: MEH-PPV e uma blenda de derivados de Polifluoreno. Nossos resultados mostram que o IZO apresenta todas as características para substituir o ITO enquanto anodo transparente em dispositivos optoeletrônicos poliméricos. Realizamos estudos detalhados das propriedades elétricas de dispositivos fabricados com MEH-PPV e com blendas de derivados de polifluorenos, com ITO ou com IZO e com ou sem camada intermediária de PEDOT, e para isso usamos as técnicas de medida estacionária (J-V) e alternada (impedanciometria). Os resultados foram analisados à luz dos modelos de injeção de Arkhipov, para resposta estacionária, e de circuitos equivalentes e de Dyre para espectroscopia em freqüência. Ao modelo de Arkhipov, adicionamos um termo de corrente de tunelamento que melhorou o ajuste para região de campos altos. Dos ajustes teórico-experimentais obtivemos importantes parâmetros dos dispositivos. / In this thesis we presented a detailed study of polymer light-emitting diodes (PLEDs) made with IZO as transparent electrode alternative to ITO. The electrical properties of thin film of IZO were studied by impedance measurements. Measurements with devices containing an additional transport layer of PEDOT were also performed. We used two different thin polymeric films for such studies: the MEH-PPV and a blend made by two polyfluorene derivatives. We also carried out a detailed investigation of several devices, making use of two techniques: by stationary J-V and by impedance measurements. The results were analyzed by the Arkhipov model (for stationary results), and by equivalent circuits and Dyre´s model for the spectroscopic results. We introduced an additional term of tunneling effect to the Arkhipov model, which improved the theoretical fitting over the experimental results at high fields. From the fittings we obtained important parameters of the produced devices.
57

FlexLoadGenerator - Um Framework para Apoiar o Desenvolvimento de Ferramentas Voltadas a Estudos de Avaliação de Desempenho e Dependabilidade

SOUZA, Débora Stefani Lima de 26 August 2013 (has links)
Submitted by Daniella Sodre (daniella.sodre@ufpe.br) on 2015-03-10T13:32:50Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Debora de Souza.pdf: 4411533 bytes, checksum: 703ab507aa1b4a6307ded18f5a64079f (MD5) / Made available in DSpace on 2015-03-10T13:32:50Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Debora de Souza.pdf: 4411533 bytes, checksum: 703ab507aa1b4a6307ded18f5a64079f (MD5) Previous issue date: 2013-08-26 / Ao longo dos anos, sistemas computacionais em diversas áreas de conhecimento têm sido desenvolvidos e incorporados ao nosso cotidiano. Independente da etapa do ciclo de vida no qual o sistema se encontre é preciso preocupar-se com os requisitos de desempenho e dependabilidade dos serviços providos. Um dos métodos utilizados para estudos de desempenho é a medição de sistemas enquanto esses são submetidos aos diferentes níveis de carga possíveis. A aplicabilidade de tal técnica geralmente envolve o uso de programas de geração de carga sintética, que têm como intuito gerar eventos de carga de trabalho que simulem usuários requisitando serviços ao sistema. A carga de trabalho ocasionada por meio dessas ferramentas também pode contribuir para pesquisas de dependabilidade, visto que o uso de carga pode colaborar para revelar comportamentos não desejáveis e falhas não visualizadas anteriormente. O uso de carga sintética não é o único caminho a ser seguido para realizar estudos de dependabilidade. Ferramentas que geram situações de falha também podem ser empregadas para alcançar este objetivo. A diversidade de funções para as quais sistemas são desenvolvidos requer que ferramentas específicas sejam construídas para a realização de experimentos de desempenho ou de dependabilidade, mesmo que haja um conjunto de conceitos comuns entre ferramentas deste tipo. Neste contexto, este trabalho propõe um framework, implementado em Java, que engloba vários métodos que podem auxiliar no desenvolvimento de ferramentas geradoras de eventos de forma mais ágil e confiável. No decorrer desta pesquisa geradores de carga, para experimentos de desempenho, e geradores de eventos de falha e reparo, para experimentos de dependabilidade, foram concebidos com o auxílio do framework, atestando, assim, sua eficiência. Por fim, estudos de caso desenvolvidos a partir dos softwares geradores de eventos serão apresentados.
58

Avaliação e desempenho da injeção ótima de polímeros em reservató-rios de petróleo

Dantas, Vinícius 19 December 2013 (has links)
Submitted by Daniella Sodre (daniella.sodre@ufpe.br) on 2015-04-10T15:41:03Z No. of bitstreams: 2 TESE Vinícius Dantas.pdf: 7342372 bytes, checksum: 911dd411fc685c93f20e4810224c4c2a (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-10T15:41:03Z (GMT). No. of bitstreams: 2 TESE Vinícius Dantas.pdf: 7342372 bytes, checksum: 911dd411fc685c93f20e4810224c4c2a (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013-12-19 / Os problemas relacionados à extração de petróleo geralmente estão relacionados à maior produtividade no campo. Dessa forma, o foco desse trabalho é subsidiar a melhor distribuição de injeção de massa de polímeros nos poços injetores capaz de resultar na otimização da recuperação de óleo. Propõe-se então fornecer técnicas computacionais que possam melhorar o fator de recuperação de hidrocarbonetos melhorando assim, a eficiência do projeto de vazão de injeção de polímeros dissolvidos na água. No processo de otimização, serão executados várias estratégias visando um melhor projeto de vazões de injeções e consumo de polímero. Para resolver este problema, é adotada uma metodologia que combina estratégias de otimização global e local, que é conhecida como estratégia híbrida de otimização. Todos os casos serão executadas através da ferramenta comercial de simulação de reservatórios IMEX (Implicit Explicit Black Oil Simulator) que faz parte do pacote de programas da CMG (Computer Modelling Group Ltd.). Os problemas de otimização serão divididos em duas partes, a primeira irá tratar das otimizações globais e em uma segunda etapa será utilizado otimização local fazendo uma hibridização dos métodos. Com esta metodologia, espera-se que haja um melhoramento no varrido no reservatório e com isso uma melhor recuperação de petróleo e consequentemente maximizando a função objetivo, Valor Presente Líquido (VPL). O trabalho proposto irá analisar a quantidade de massa de polímero injetada em um reservatório sintético e em um reservatório baseado em dados reais, avaliando as vazões de injeção de cada poço injetor, bem como, o tamanho do banco de polímeros e sua concentração.
59

Ensaios de respirometria : monitorização do CO2 utilizando um sistema FIA com detecção condutometrica

Andreo, Ana Paula 20 July 1999 (has links)
Orientador: Jose Roberto Guimarães / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-26T20:50:05Z (GMT). No. of bitstreams: 1 Andreo_AnaPaula_M.pdf: 6332629 bytes, checksum: 6b02356f946557e0aca1e2bf5148fc7f (MD5) Previous issue date: 1999 / Resumo: A respirometria é uma técnica muito utilizada na determinação da biodegradação de resíduos misturados ao solo pela atuação de microrganismos presentes. O respirômetro normalmente utilizado é o de Bartha e Pramer, onde o CO2 produzido durante o processo é determinado via titulação ácido-base (convencional). O presente trabalho teve como objetivo a determinação do CO2 biodegradado, (CO2)b através de análise por injeção em fluxo (FIA) com detecção condutométrica, uma técnica cujas características são precisão, sensibilidade e curto tempo de resposta. Para tanto, fez-se necessário o estudo de parâmetros operacionais do sistema FIA utilizado. Realizou-se então ensaios de respirometria seguindo o Projeto de Norma 01:603.06-007/1993 da ABNT, com determinações do ((CO2)b por titulação e por sistema FIA. Os resultados obtidos foram bastante satisfatórios, verificando nas curvas obtidas o mesmo comportamento previsto pela teoria, permitindo assim, a identificação das fases do crescimento microbiano / Abstract: Respirometry is a technique frequently used for the determination of biodegradation of residues that are mixed to the soil, through the action of microorganisms present in it. The respirometer normally used is the Bartha and Pramer, in which the CO2 produced during the process is determined through acid-base volumetric analysis (conventional). The present work had as an objective the determination of the biodegraded CO2, (CO2)b, through the Flow Injection Analysis (FIA) with condutometric detection, a respected technique whose characteristics are precision, sensibility and shot response time. For this, the study of operation parameters of the FIA system used was made necessary, Assay of respirometry were done following the Project of Norm 01:603-06-007/1993 of ABNT, with the determination of (CO2 through volumetric analysis and FIA system. The results obtained are very satisfactory. It was possible to identify that the obtained curves present the same behavior as expected in theory, allowing the identification of the phase of microbiological growth / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
60

Estudo comparativo de sistemas de analises quimicas em fluxo empregando FIA com multicomutação e amostragem binaria, FIA com amostragem sanduiche, fluxo monossegmentado e injeção sequencial

Vieira, Jonas Alves 28 July 2018 (has links)
Orientadores: Ivo Milton Raimundo Junior, Boaventura Freire dos Reis / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-28T09:59:36Z (GMT). No. of bitstreams: 1 Vieira_JonasAlves_D.pdf: 3574022 bytes, checksum: f3483b89a225531ceb5aaa8de6572fee (MD5) Previous issue date: 2001 / Doutorado

Page generated in 0.0397 seconds