• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 639
  • 7
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 656
  • 403
  • 112
  • 66
  • 62
  • 47
  • 46
  • 43
  • 39
  • 39
  • 37
  • 36
  • 33
  • 32
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
341

Avaliação da instrumentação rotatória com limas de níquel e titânio, K3 e RaCe, em canais radiculares curvos simulados

Leonardi, Denise Piotto [UNESP] 16 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-16Bitstream added on 2014-06-13T19:52:07Z : No. of bitstreams: 1 leonardi_dp_me_arafo.pdf: 741813 bytes, checksum: 2517134a5a1799a4a8f6f37ddf2985b0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foram analisadas, comparativamente, a ação e a presença de deformações proporcionadas pela instrumentação com limas manuais Flexofile e dois Sistemas Rotatórios de Limas Endodônticas de Níquel e Titânio: o Sistema K3 (SDS Kerr) e o Sistema Race (FKG), sobre as paredes dos canais radiculares curvos simulados em blocos de resina. Foram utilizadasa as técnicas manual e ultra-sônica de irrigação. Após a instrumentação, os blocos de resina foram digitalizados, analisados e estabelecido escores de acordo com a qualidade do preparo biomecânico obtido em cada uma das técnicas. Concluímos que os melhores resultados foram obtidos com as duas técnicas de instrumentação rotatória associadas à irrigação manual. / It were comparatively analyzed the action and aberrations provided by the instrumentation using manual files Flexofile and two Rotary Systems of Endodontic Nickel-Titanium files, the K3 (SDS Kerr) System and the Race (FKG) System, in the curved root canal walls simulated in resin blocks, with two irrigations techniques: a manual and an ultrasonic technique. Thereafter the instrumentation, the resin blocks were digitalized, analysed and scores were set according to the preparation's quality achieved in each technique. It was ended that the best results were obtained with the two techniques of rotary instrumentation associated to the manual irrigation.
342

Vibrações induzidas por multidões: efeito nos movimentos corpóreos dos pedestres na direção transversal

Silva, Felipe Feliciano Gomes da 15 August 2016 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-06-05T12:42:07Z No. of bitstreams: 1 arquivototal.pdf: 3657172 bytes, checksum: 49a2dbaae14b810a2f42bd26d7f5f3db (MD5) / Made available in DSpace on 2017-06-05T12:42:07Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 3657172 bytes, checksum: 49a2dbaae14b810a2f42bd26d7f5f3db (MD5) Previous issue date: 2016-08-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The analysis of the vibrations induced by crowds in the transverse direction has become a topic of increasing interest, because of the ocurrence of excessive transverse vibrations in certain structures due to pedestrian traffic. This work presents the analysis of movements of pedestrians in the transverse direction for crowd situations. Successive tests were carried out with persons instrumented, walking alone and in a crowd. Comparisons between measurements of these pedestrians walking alone and in the crowd provided the identification of the influence of the crowd in the transverse acceleration and displacements and rotation of the pelvis. / A análise de vibrações induzidas por multidões na direção transversal vem se tornando um tema cada vez de maior interesse devido a ocorrência de vibrações transversais excessivas em algumas estruturas destinas à circulação de pedestres. Este trabalho apresenta a análise de caminhadas/movimentos na direção transversal para situações de multidão. Para obtenção dos dados experimentais foram feitos testes sucessivos com pessoas instrumentadas, caminhando isoladamente e em meio a uma multidão com densidades diferentes. A análise comparativa dos sinais destes pedestres caminhando só e em multidão, possibilitou a identificação da influência causada por essa multidão na aceleração e deslocamento transversal e na rotação da pélvis.
343

Desenvolvimento de um sistema de espectroscopia de impedância elétrica multicanal / Multichannel electrical impedance spectroscopy system

Pereira, Rogério Martins 30 July 2009 (has links)
Made available in DSpace on 2016-12-12T17:38:36Z (GMT). No. of bitstreams: 1 Rogerio Martins Pereira.pdf: 8981376 bytes, checksum: 99bc38e35b4ba47ede892b1ed9f09d6b (MD5) Previous issue date: 2009-07-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Over 40 years the Electrical Impedance Spectroscopy (EIS) has been used to investigate pathologies in biological tissues by analyzing its electrical properties and associate them to a tissue equivalent circuit model. The EIS technique consists of applying a multifrequency current of constant amplitude by two electrodes, measuring the resulting potential by other two electrodes and then extract the electrical parameters from a tissue model by calculating the transfer impedance (ZT). The main objective of this work is to develop an EIS multichannel system for impedance probes within the frequency range of 500 Hz to 1 MHz. A voltage controlled current source (VCCS) circuit and a fully controlled multiplexing system were developed. The potentials were measured by a Data Acquisition (DAQ) board. A software developed in LabVIEW was implemented in order to control and calibrate the hardware, and also to process the data in the calculation of the complex impedance and its electric tissue parameters. In order to present the data and to get an easy-to-use front panel, a graphical interface was developed. This allows one to select both injecting and measuring channels, to present the measured signal in real time and in the frequency domain, which can be chosen between the modulus and phase of the transfer impedance ZT. Preliminary tests were made in the hardware by using resistive loads. The results showed that the frequency response of the developed EIS multichannel system is band limited. Therefore, a compensation process technique was implemented and then fully tested. The results showed that the compensation technique increases the accuracy of the system to approximately 95% in the range of 500 Hz to 1 MHz, with resistive loads. Measurements in tissue equivalent circuits (phantoms) were made and its electrical tissue parameters were calculated. The results showed that the measured data can be easily fitted to the phantoms with a maximum error of 5%. Tissue impedances were measured by an electrode impedance probe. Firstly, the probe was calibrated by using saline solutions with conductivities from 1,0 to 10,0 mS/cm. The objective was to reconstruct the conductivities from measured data. The results showed na accuracy of 98% in the reconstruction within the frequency range of 500 Hz to 200 kHz. Second, measurements in five different samples of bovine tissue were made and their respective electrical parameters were calculated. In order to characterize the bovine tissue, the reactive part of the transfer impedance was plotted against the resistive part and their respective electric parameters were calculated. It can be concluded that the performance of the developed EIS multichannel system was achieved in the frequency range of 500 Hz to 200 kHz. Stray capacitances from the multiplexing system, cable capacitances and the input capacitance of the DAQ board reduced the system frequency range. However, feasible tissue data can be obtained by this system and so tissue characterization may be performed for pathologies identification. / O processo em Espectroscopia de Impedância Elétrica (EIE) para levantamento da impedância elétrica consiste na injeção de uma corrente CA de amplitude constante, ao longo de uma faixa de freqüência, através de dois eletrodos, na medição do potencial resultante e, então, no cálculo da impedância de transferência ZT. EIE é uma técnica usada na determinação de patologias em tecidos biológicos através da análise dos parâmetros elétricos equivalentes do tecido. Estes parâmetros são obtidos através da medição da impedância de transferência do material analisado. O objetivo deste trabalho é desenvolver um sistema EIE multicanal, utilizado em sondas com até oito eletrodos, operando na faixa de freqüência de 500 Hz a 1 MHz. No circuito eletrônico do sistema foi desenvolvida uma fonte de corrente controlada por tensão e um sistema de multiplexação e demultiplexação. Através de uma placa de aquisição de dados, uma plataforma de controle foi desenvolvida em LabVIEW, dispondo de funções especiais para o cálculo da impedância complexa e dos parâmetros elétricos dos tecidos, para a calibração e o armazenamento dos dados. Também foi desenvolvida uma interface gráfica amigável para a manipulação dos dados e seleção dos canais de medição e apresentação dos sinais medidos em tempo real e no domínio da freqüência através do espectro da impedância ZT e das suas componentes: módulo e fase. Testes foram realizados no sistema utilizando cargas puramente resistivas. Os resultados mostraram que o sistema EIE responde de maneira não linear com a freqüência. Após o processo de compensação, obteve-se uma exatidão de 95% na faixa de 500 Hz a 1 MHz. Medições em phantoms (circuitos equivalentes elétricos de tecidos) foram feitas, mostrando que seus respectivos parâmetros podem ser calculados com uma exatidão média de 95%. Utilizando uma sonda de eletrodos, o sistema EIE+sonda foi calibrado através de soluções salinas com condutividades na faixa de 1,0 a 10,0 mS/cm. Os resultados mostraram uma exatidão de 98% no cálculo das condutividades até 200 kHz. Medições feitas em leite de vaca mostraram que é possível identificar o seu teor de gordura. Medições em cinco amostras diferentes de tecido bovino foram feitas e seus respectivos parâmetros elétricos foram calculados. De maneira geral, o sistema EIE multicanal desenvolvido apresentou desempenho satisfatório, embora capacitâncias parasitas nos circuitos, no cabo da sonda e na placa de aquisição prejudicaram sua exatidão nas altas freqüências. Pode-se concluir que é de fundamental importância o uso de técnicas de compensação e calibração para que medições em tecidos biológicos sejam possíveis com este equipamento.
344

Estudo comparativo do preparo do canal radicular de dentes artificiais utilizando diferentes técnicas automatizadas de instrumentação /

Camargo, Maurício. January 2004 (has links)
Orientador: Renato de Toledo Leonardo / Banca: Idomeo Bonetti Filho / Banca: Roberto Miranda Esberard / Banca: Manoel Eduardo de Lima Machado / Banca: Carlos Alberto Ferreira Murgel / Resumo: Foram avaliados comparativamente três sistemas de técnicas automatizadas de preparo dos canais radiculares, Endo-Eze, K3 e Race. Neste trabalho, foram utilizados 30 pré-molares artificiais, confeccionados em resina, com canais radiculares únicos, com curvatura de quarenta graus. Para a avaliação do preparo dos canais radiculares, os dentes foram divididos em três grupos, incluídos em blocos de resina e seccionados no terço apical das raízes. As secções das raízes foram fotografadas antes e após a instrumentação de forma padronizada e as imagens transferidas para o computador que procedeu às análises comparativas. A avaliação baseou-se na extensão do deslocamento, na direção do movimento do centro do canal radicular e na área desgastada. Em relação ao preparo dos canais, os sistemas Endo-Eze e K3, apresentaram um deslocamento do centro do canal radicular maior do que o sistema Race. Menores valores de desgaste foram observados para o sistema Race, seguido dos sistemas K3 e Endo-Eze. Os dentes utilizados neste estudo mostraram-se eficazes na avaliação de diferentes técnicas de instrumentação. / Abstract: Three different systems of automated instrumentation techniques of root canal preparation were evaluated, Endo-Eze, K3 and Race. Thirty single rooted artificial resin pre-molars were manufacture with an apical curvature of 40-degree angle each. For the evaluation of the root canal preparation, the artificial teeth were divide in three groups, included in resin blocks and sectioned at the apical third. The sections were photographed before and after the instrumentation on a standardize way and the images obtained were transferred to a computer for the comparative analysis. The evaluation was based on the extension of canal displacement, the direction of the canal center movement and at the removed area. Concerning the root canal preparations, the Endo-Eze and K3 systems presented a bigger deviation of the center of the original root canal bigger them the Race system. Lower values for the Race system were observed fallowed by the K3 and Endo-Eze. The artificial teeth utilized in this study were efficient for the evaluation of different automated instrumentation techniques. / Doutor
345

Avaliação da extrusão bacteriana apical após instrumentação mecanizada com sistemas reciprocantes de instrumento único comparados a um sistema rotatório multi-instrumento / Apical extrusion of bacteria by reciprocating single file systems and rotary multi-file system

Justine Monteiro Monnerat Tinoco 27 September 2013 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O objetivo deste estudo foi avaliar ex vivo a extrusão bacteriana apical após instrumentação mecanizada com sistemas reciprocantes de instrumento único e movimento reciprocante (WaveOne and Reciproc) comparados a um sistema multi-instrumentos (BioRaCe). Quarenta e cinco incisivos inferiores humanos unirradiculares, ovais e de anatomia semelhante foram utilizados. Os dentes foram acessados e seus canais radiculares foram contaminados com uma suspensão de Enterococcus faecalis e incubados por 30 dias possibilitando crescimento bacteriano em biofilme. Os dentes contaminados foram divididos em três grupos com 15 espécimes cada (RE - Reciproc, WO -WaveOne e BR - BioRaCe). Foram utilizados oito dentes para grupos controle de crescimento bacteriano positivo e negativo. As bactérias extruídas apicalmente durante a instrumentação foram coletadas em frascos de vidro contendo 0,9% de NaCl. As amostras microbiológicas foram retiradas dos frascos e incubadas em meio BHI ágar, durante 24 horas. O crescimento bacteriano foi contado e os resultados foram expressos em unidades formadoras de colônia (UFC). Os dados foram analisados pelos testes estatísticos de Wilcoxon e Kruskal-Wallis. Não houve diferença estatisticamente significante no número de UFC entre os dois sistemas reciprocantes (p>0,05). Em contrapartida, o sistema de instrumentos rotatórios mostrou uma quantidade de UFC significativamente maior do que os dois outros grupos (p <0,05). A partir da análise dos resultados e dentro das limitações deste estudo foi possível concluir que todos os sistemas de instrumentação testados extruem bactérias apicalmente. No entanto, ambos os sistemas de instrumento único e movimento reciprocante extruem menos bactérias apicalmente do que o sistema rotatório multi-instrumentos de referência. / The aim of this work was to evaluate ex vivo the apical bacterial extrusion of reciprocating single-file systems (Wave One and Reciproc) compared to a multi-file rotary system (BioRaCe). This was tested in the current study using extracted, single-rooted teeth with oval canals (n = 45) with similar anatomy. Endodontic access cavities were prepared and root canals were contaminated with an Enterococcus faecalis suspension and incubated for thirty days to promote bacterial biofilm growth. The contaminated teeth were divided into three groups with 15 specimens each (RE - Reciproc, WO- Wave One and BR - BioRaCe). Positive and negative bacterial growth control groups were done. Bacterial extruded from the apical foramen during instrumentation were collected into vials containing 0.9% NaCl. The microbiological samples were taken from the vials and incubated in BHI agar medium during 24h. Bacterial growth was counted and the results were given by colony-forming units (CFU). These data were analyzed by Wilcoxon matched-pairs signed rank test and KruskalWallis H-test. After data analysis, no significant difference was found in the number of CFU between the two reciprocating systems (p > 0.05). Conventional multi-file rotary system group showed significantly higher CFU than both of the other two reciprocating groups (p<0.05). Based on the results evaluation and within the limitation of this study, it was possible to conclude that all tested instrumentation systems extruded bacteria beyond the apex. However, both reciprocation single-file systems apically extruded fewer bacteria than the conventional multi-file rotary system.
346

Desenvolvimento de uma plataforma de força multiaxial para instrumentação biomédica / Development of a multiaxis force plate for biomedical instrumentation

Urquiza, Marcelle Alencar 29 August 2005 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The evolution of techniques for the development of equipment capable of translating the results taken from a diverse and complex set of tasks carried out by the human body, has become an important item on the scientific communities agenda. Within the context of such equipment, the force plate has shown itself capable of being implemented for the task of measuring phenomena, which before could only be observed visually. This work has as its objective to describe and develop an extensometric, multiaxial force plate, for use as a biomedical assistance apparatus. Sensors for the detection of forces such as strain gauges were used and fixed in predetermined areas on the four transducers, which are an integral and fundamental part of the force plate apparatus. The cell design was completed using geometry capable of coupling with the minimum of interference the two different forces present within the structure. In this manner it is possible to quantify the forces in three orthogonal directions. The prototype developed can be utilized, for example as an evaluation tool for both gait and stability research. In parallel to the development of the force plate, equipment for carrying out the conditioning and digitalization of signals originating from the load cells was designed and constructed. The control of the acquisition processes as well as the processing of signals received from the force plate is carried out by the use of a specific applicative, which makes the quantitative values of the forces, strength and momentum available, allowing for the calculation of the parameters used for the respective biomedical evaluations, especially those dealing with the oscillation of the human body in an erect near static posture. Still further the applicative provides a confidence ellipse obtained from the stability evaluations carried out along with the coordinates of pressure center and standard stability indexes obtained instantaneously. / A evolução das técnicas para desenvolver equipamentos capazes de traduzir o resultado de diversas tarefas complexas exercidas pelo corpo humano, tornou-se evidente para a comunidade científica. Dentre esses equipamentos, a plataforma de força mostrou ser uma ferramenta capaz de ser empregada para a mensuração de fenômenos antes só observados. Este trabalho tem por objetivo descrever o projeto e o desenvolvimento de uma plataforma de força extensométrica, multiaxial, para uso em instrumentação biomédica. Sensores para detecção de esforços, do tipo strain gauge, foram utlizados e fixados em regiões previamente determinadas nos quatro transdutores que compõem o conjunto da plataforma. O projeto das células considera uma geometria capaz de desacoplar, com mínima interferência, dois esforços diferentes, presentes na mesma estrutura. Assim, pode-se quantizar esforços em três direções ortogonais. O protótipo desenvolvido pode ser utilizado como ferramenta para avaliações de marcha e estabilidade, por exemplo. Paralelamente ao desenvolvimento da plataforma, um equipamento para realizar o condicionamento e digitalização dos sinais provenientes das células de carga foi projetado e construído. O controle dos processos de aquisição e processamento dos sinais advindos da plataforma de força é realizado através de um aplicativo específico que disponibiliza os valores quantitativos dos esforços de força e momento, os quais permitem o cálculo de parâmetros relevantes às avaliações biomédicas, particularmente em avaliações a cerca da oscilação do corpo humano na postura ereta quasi-estática. O aplicativo fornece ainda as elipses de confiança obtidas a partir das avaliações de estabilidade realizadas, juntamente com as coordenadas do centro de pressão e índices de estabilidade padrão e instantâneos obtidos. / Mestre em Ciências
347

Influência do limite e do calibre apical após a instrumentação mecanizada com instrumentos reciprocantes na extrusão bacteriana apical / Influence of limit and apical caliber after mechanical instrumentation with reciprocating instruments in bacterial extrusion

João Marcelo da Silva Teixeira 11 February 2014 (has links)
O objetivo deste estudo foi avaliar ex vivo a extrusão bacteriana apical após instrumentação com um sistema de instrumento único reciprocante e verificar a influência de diferentes limites e diâmetros apicais nesta. Sessenta e quatro raízes de pré-molares foram utilizadas. Os dentes foram acessados e seus canais radiculares foram contaminados com uma suspensão de Enterococcus faecalis e incubados por 30 dias possibilitando crescimento bacteriano em biofilme. Os dentes contaminados foram divididos em quatro grupos com 15 espécimes cada. O calibre dos instrumentos utilizados e comprimento de trabalho de cada grupo foram respectivamente R25 à 0mm do forame, R25 aquém 1mm, R40 a 0mm e R40 aquém 1mm. Foram feitos grupos controle de crescimento bacteriano positivo e negativo. As bactérias extruídas apicalmente durante a instrumentação foram coletadas em frascos de vidro contendo 0,9% de NaCl. As amostras microbiológicas foram retiradas destes frascos e incubadas em meio BHI ágar, durante 24 horas. O crescimento bacteriano foi contado e os resultados foram expressos em unidades formadoras de colônia (UFC). Os dados foram analisados pelo teste estatístico de Kruskal-Wallis. Não houve diferença estatisticamente significante no número de UFC entre os quatro grupos (p>0,05). A partir da análise dos resultados e dentro das limitações deste estudo foi possível concluir que independente do comprimento de trabalho e da ampliação foraminal haverá similar quantidade de extrusão bacteriana. / The aim of this work was to evaluate ex vivo the apical bacterial extrusion after instrumentation with a single instrument reciprocating system and the influence of differents working lengths and apical diameters on it. Sixty-four premolar roots were used. Endodontic access cavities were prepared and root canals were contaminated with an Enterococcus faecalis suspension and incubated for thirty days to promote bacterial biofilm growth. The contaminated teeth were divided into four groups with 15 specimens each. The files used and lengths from each group were respectively R25 at 0mm from foramen, R25 1mm shorter, R40 at 0mm from foramen and R40 1mm shorter. Positive and negative bacterial growth control groups were done. Bacterial extruded from the apical foramen during instrumentation were collected into vials containing 0.9% NaCl. The microbiological samples were taken from the vials and incubated in BHI agar medium during 24h. Bacterial growth was counted and the results were given by colony-forming units (CFU). These data were analyzed by KruskalWallis H-test. After data analysis, no significant difference was found in the number of CFU among the four groups (p > 0.05). Based on the results evaluation and within the limitation of this study, it was possible to conclude that regardless of the working length and foraminal enlargement will be similar amount of bacterial extrusion.
348

Caracterização geotécnica do campo experimental da UFRGS em areia / Geotechnical characterization of experimental field of UFRGS in sand

Brochero, José Luis Rodriguez January 2014 (has links)
Contribuir ao entendimento dos mecanismos que controlam o comportamento da interação estaca-solo, em estacas de grande diâmetro executadas em perfil arenoso, foi a principal motivação que levou a propor a criação de um campo experimental, concebido para realização de um programa de ensaios de provas de carga instrumentadas. Este processo deu inicio com o desenvolvimento desta pesquisa, que descreve a caracterização geotécnica da área de estudo. As investigações geotécnicas iniciais foram compostas por ensaios de campo; ensaios de penetração padrão (SPT), ensaios dilatométricos (DMT) e ensaios de piezocone (CPTu), além de ensaios de laboratório de caracterização, representados por ensaios de umidade natural e ensaios granulométricos. Os ensaios de campo permitem obter parâmetros constitutivos do perfil da área de estudo, sendo possível junto à descrição geológica, fazer algumas inferências que foram determinantes para o processo de concepção das provas de carga instrumentadas. Uma revisão de aspectos geológicos foi realizada, caracterizando-se o contexto regional e a gênese das planícies costeiras do estado de Santa Catarina, área onde foi localizado o campo experimental. Ênfase é dada á instrumentação das estacas, sendo elementos essenciais para a realização das provas de carga e analises posteriores, incluindo, diversas recomendações para instrumentação tanto no topo como no fuste das estacas. Previsões de capacidade de carga através de três métodos de cálculo, dimensionamento do sistema de reação, metodologia de carregamento e instrumentação fazem parte das contribuições resultantes da realização desta pesquisa, subsidiando a execução das provas de carga de pesquisas futuras. Estes subsídios foram projetados em base a normativas nacionais e internacionais, além da recopilação de diferentes experiências relatadas na literatura, as quais estão incluídas na revisão bibliográfica. / Contributing to the understanding of the mechanism controlling the behavior of the pile-soil interaction in large diameter piles in sand was the main motivation of the present research. This led to the creation of an experimental testing site designed to test large diameter instrumented piles. This process has started with the development of this research, which describes the geotechnical characterization of the area. Geotechnical investigations comprised field test: standard penetration tests (SPT), dilatometer tests (DMT) and cone penetration tests (CPTu), as well as laboratory tests to determinate the natural moisture and soil granulometric curves. Field studies allow obtaining constitutive parameters of the profile of the study area that beside the geological description, allowed inferences regarding the instrumentation of piles. A review of geological features was held, characterizing the regional deposition and the genesis of the coastal area of the state of Santa Catarina, where the experimental field was located. Emphasis is given to the instrumentation of piles, essential for the analyses of test, including several recommendations for instrumentation in both the top and shaft. Estimation of load capacity by three methods of calculation, design of the reaction system, methodology of loading stages and instrumentation are part of the contributions resulting from this research, giving support to the load tests in future research. These contributions are based on national and international standards, support by the compilation of different experiences reported in the literature, which are included in the literature review.
349

Segurança de barragens : análise da instrumentação da barragem de Itaúba / Safety of dams : Analysis of instrumentation of Itaúba dam

Smiderle, Camila de Souza Dahm January 2014 (has links)
Neste trabalho foi feita a análise das leituras da instrumentação da barragem de terra e enrocamento de Itaúba, localizada no centro do estado do Rio Grande do Sul, coletada ao longo de 35 anos. A auscultação por instrumentação atual inclui medidores de vazão, piezômetros, marcos de deslocamento superficial e medidor de recalque tipo KM, compondo um banco de dados de 10.000 dados de leitura. Foi observado que as vazões medidas através dos drenos de fundação da barragem reduziram pela metade desde o primeiro ano de operação da barragem até o final de 2013, embora os níveis piezométricos do sistema de drenagem à jusante não tenham sofrido alteração. As vazões dos filtros inclinado e vertical são afetadas pelas chuvas, mesmo assim foi possível concluir que as vazões reduziram 1/3 em comparação com a vazão logo após o segundo enchimento do reservatório. A vazão pela barragem e fundação era de 1.800 l/min no primeiro ano de operação decrescendo para 930 l/min (dez / 2013). Observou-se que até o fim do período construtivo já haviam ocorrido 101,75cm de recalque (92% de todo o recalque medido). Os recalques do núcleo estabilizaram entre o 5° e 10° ano de operação da barragem, isto é, desde 1988 a barragem não apresenta recalques significativos. O recalque total de Itaúba foi de 109,6cm que representa 1,2% da altura da seção onde o medidor de recalque está instalado. A análise permite concluir que a Barragem de Itaúba esta estabilizada quanto aos deslocamentos verticais e horizontais. Apesar de tratarse de dados de leituras coletados desde 1976, as informações apresentadas aqui são de relevante interesse e ainda não haviam sido publicadas. / In this work, the analysis of Itauba dam instrumentation is carried out. This earth and rock fill dam is located in the center of Rio Grande do Sul state and the readings cover its 35 years of operation. The currentinstrumentation includes flow meters, piezometers, surface displacement and settlements gauge type KM, composing a 10,000 reading database. It was observed that the flow rates measured through the dam foundation drains reduced to half since the first year of dam operation, although the piezometric levels of the downstream drainage system showed no significant change. Flow rates of inclined and vertical filters are affected by the rains, even so it was still possible to conclude that the flows reduced circa of 1/3 compared to the flow after the second filling of the reservoir. The flow through the dam and foundation which was 1,800 l / min in the first year of operation decreased to 930 l / min (Dec / 2013). It was observed that by the end of the construction period had occurred 101,75cm of settlement (92% of all the measured settlement). The settlement core stabilized between the 5 th and 10th year of dam operation, that is, since 1988 the dam does not present significant settlements. The total discharge of Itaúba was 109,6cm representing 1.2% of the section height where repression meter is installed. The analysis shows that the Itaúba dam has stabilized its vertical and horizontal displacements.
350

Contribuição ao desenvolvimento de transdutores indutivos de deslocamento

Motta, Eduardo Costa da January 2002 (has links)
O presente trabalho enfoca o estudo de transdutores indutivos de deslocamento linear. Dentre os diversos dispositivos dessa natureza, procurou-se desenvolver um estudo mais aprofundado do transdutor indutivo diferencial com núcleo de esferas. O desenvolvimento experimental, com a construção de quatro protótipos, levou ao projeto de um transdutor com características adequadas ao uso industrial. / The present work focuses on the study of inductive transducers of linear displacement. Among the several devices of that nature, a more detailed study of the inductive differential transducer was attempted with core of spherical balls. The experimental development of four prototypes resulted in a transducer with characteristics adequate for industrial use to be designed.

Page generated in 0.1064 seconds