• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 29
  • Tagged with
  • 29
  • 29
  • 29
  • 29
  • 29
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Sistemas amperométricos empregando matrizes de microeletrodos e análises simultâneas / Amperometric system using array of microelectrode and simultaneous determinations

Renato Camargo Matos 17 August 2001 (has links)
No presente trabalho são descritos métodos versáteis para determinações simultâneas multicomponentes. Estes são baseados num sistema de detecção multicanal acoplado a célula em fluxo contendo um conjunto de microeletrodos modificados. O primeiro método mostra a quantificação amperométrica em fluxo de ácido ascórbico (AA), dopamina (DA), epinefrina (EP) e dipirona (DI) em misturas (na faixa de &#181;g g-1). Neste trabalho foi utilizado um conjunto de microeletrodos de ouro limpos e modificados, independentemente, com diferentes metais nobres (Pt, Pd e uma mistura equimolar de Pd e Pt), associados com métodos de calibração multivariada. As análises de amostras sintéticas e formulações farmacêuticas contendo AA e DI apresentaram valores muito similares aos encontrados com a iodometria clássica. O método apresentou um erro médio absoluto (em &#181;g g-1) de 0,3, 0,1, 0,4 e 0,3 para AA, DA, EP e DI, respectivamente, para a regressão linear múltipla e 0,3, 0,4, 0,4 e 0,2 para AA, DA, EP e DI, respectivamente, para a regressão por mínimos quadrados parciais. O segundo trabalho apresenta um método para determinação amperométrica diferencial de peróxido de hidrogênio em águas de chuvas em associação com análise por injeção em fluxo e imobilização de catalase em reator tubular usando glutaraldeído e resina amberlite IRA - 743 como suporte. A curva de calibração para o peróxido de hidrogênio foi linear na faixa de concentração de 1 a 10 x 10-6 mol L-1 com um desvio relativo padrão (RSD) < 1%. O limite de detecção do método foi calculado em 2,9 x 10-7 mol L-1. As análises de águas de chuvas foram comparadas com amperometria usando microeletrodo de mercúrio e espectrofotometria, sendo que os resultados mostraram uma boa correlação. O terceiro método descreve a determinação amperométrica simultânea em fluxo de glicose e ácido úrico, usando dois microeletrodos com diferentes composições (Pt e Pt+glicose oxidase+acetato de celulose) e detecção multicanal. A curva de calibração para a glicose foi linear na faixa de concentração de 1 a 10 x 10-4 mol L-1 com um desvio relativo padrão (RSD) < 1%. O limite de detecção do método foi calculado em 5 x 10-5 mol L-1. As análises de amostras sintéticas foram comparadas com o método espectrofotométrico, mostrando uma boa concordância entre os resultados obtidos. / In the present work, versatile methods for simultaneous amperometric multicomponent analysis are described. They are based on a multi-channel detection system, coupled to a flow cell containing an array of modified microelectrodes. The first method shows the flow injection amperometric quantification of ascorbic acid (AA), dopamine (DA), epinephrine (EP) and dipyrone (DI) in mixtures (in the &#181;g g-1 range). This work was successfully performed by using an array of microelectrodes bare and with units modified by the electrodeposition of different noble metals (platinum, palladium or a mixture of platinum+palladium), together with multivariate calibration analysis. The analysis of synthetic samples and pharmaceutical compounds containing AA and DI led to very similar values to those obtained by the classical iodometric analysis. The average absolute errors (in &#181;g g-1) calculated for each analyte were 0.3, 0.1, 0.4 and 0.3 for AA, DA, EP and DI, respectively, for multiple linear regression and 0.3, 0.4, 0.4 e 0.2 for AA, DA, EP and DI , respectively, for partial least square regression. The second study presents a method for differential amperometric determination of hydrogen peroxide in rainwater in association with flow injection analysis and immobilized catalase enzymes in a tubular reactor using glutaraldeyde and amberlite IRA - 743 which support. The calibration curves for hydrogen peroxide standards was linear in the concentration range from 1 to 10 x 10-6 mol L-1 with a relative standard deviation (RSD) < 1 %. The detection limit was calculated as 2.9 x 10-7 mol L-1. The rainwater samples analyses where compared with the amperometric using mercury microelectrode and spectrophotometric methods, showing very good correlation between all the methods. The third method describes the flow injection amperometric determination of glucose and uric acid simultaneously, using two microelectrodes with different composition (platinum and platinum+glucose oxidase+cellulose acetate) and a multi-channel detection system. The calibration curves for glucose standards was linear in the concentration range from 1 to 10 x 10-4 mol L-1 with a relative standard deviation (RSD) < 1 %. The detection limit was calculated as 5 x 10-5 mol L-1. The analyses of synthetic samples were compared with the spectrophotometric method, showing very good correlation between the methods.
12

Desenvolvimento de processo de titulação por procura binária, em fluxo contínuo, com detecção espectrofotométrica / Development of titration process by search binary, in flow continuous, with spectrophotometric detection

Korn, Mauro 28 February 1996 (has links)
O processo de análise química denominado de titulação por procura binária foi desenvolvido e aplicado em sistema de injeção em fluxo. Este procedimento de análise, baseado no método das variações contínuas, procura o menor intervalo em fração volumétrica do titulante, ou da solução da amostra, que contenha o ponto final de uma titulação. Ao ser introduzida alíquota da solução da amostra no percurso analítico, o sinal gerado pelo detector deve ser significativamente diferente daquele gerado com a inserção de uma alíquota da solução do titulante. Neste processo descontínuo, a procura do ponto final segue a lógica binária, reduzindo os incrementos de fração volumétrica, da solução de amostra ou do titulante, em 50%, a cada nova tentativa de procura. Os sinais gerados por um detector espectrofotométrico, acoplado ao sistema de fluxo, eram convertidos em sinais digitais e comparados com os sinais fornecidos pelo detector nas duas tentativas iniciais da procura. Um programa foi desenvolvido para gerenciar este procedimento de titulação, determinando o volume das alíquotas das soluções, para cada tentativa, bem como estabelecendo a rota de procura. O procedimento foi aplicado à uma série de titulações envolvendo reações de neutralização e complexação. Uma titulação, aplicando este procedimento, pode ser executada em 3 minutos, consumindo aproximadamente 2 cm3 das soluções reagentes. As limitações para a aplicação deste procedimento de análise são discutidas, bem como a inviabilidade de sua aplicação sem o emprego de recursos de automatização. / A flow injection analytical procedure named as binary search titrimetric process was studied. It was based on volumetric fraction variation methodology. Under its directive, the microcomputer can control the titrand and titrant solutions delevering into the analytical path, by varying both volumetric fractions, following an algorithm based on successive aproximation method. Analytical signals assessed from the analog output of the spectrophotometer for each tentatives were converted to digital making use of an interface card, attached in the microcomputer main board. After each solutions handling cycles, the data collected were processed in order to decide about the next tentative to be carried out, obeying the settled binary search algorithm. The feasibility was ascertained by titrating solutions employing neutralization and complexation reactions. The time interval to perform this titration process employing binary search concept was about 3 minutes, consuming ca 2 cm3 of reagents solutions. No significant difference at 5 % probability level was observed by comparing of the results obtained applying this procedure with those produced by manual procedures.
13

Desenvolvimento de processo de titulação por procura binária, em fluxo contínuo, com detecção espectrofotométrica / Development of titration process by search binary, in flow continuous, with spectrophotometric detection

Mauro Korn 28 February 1996 (has links)
O processo de análise química denominado de titulação por procura binária foi desenvolvido e aplicado em sistema de injeção em fluxo. Este procedimento de análise, baseado no método das variações contínuas, procura o menor intervalo em fração volumétrica do titulante, ou da solução da amostra, que contenha o ponto final de uma titulação. Ao ser introduzida alíquota da solução da amostra no percurso analítico, o sinal gerado pelo detector deve ser significativamente diferente daquele gerado com a inserção de uma alíquota da solução do titulante. Neste processo descontínuo, a procura do ponto final segue a lógica binária, reduzindo os incrementos de fração volumétrica, da solução de amostra ou do titulante, em 50%, a cada nova tentativa de procura. Os sinais gerados por um detector espectrofotométrico, acoplado ao sistema de fluxo, eram convertidos em sinais digitais e comparados com os sinais fornecidos pelo detector nas duas tentativas iniciais da procura. Um programa foi desenvolvido para gerenciar este procedimento de titulação, determinando o volume das alíquotas das soluções, para cada tentativa, bem como estabelecendo a rota de procura. O procedimento foi aplicado à uma série de titulações envolvendo reações de neutralização e complexação. Uma titulação, aplicando este procedimento, pode ser executada em 3 minutos, consumindo aproximadamente 2 cm3 das soluções reagentes. As limitações para a aplicação deste procedimento de análise são discutidas, bem como a inviabilidade de sua aplicação sem o emprego de recursos de automatização. / A flow injection analytical procedure named as binary search titrimetric process was studied. It was based on volumetric fraction variation methodology. Under its directive, the microcomputer can control the titrand and titrant solutions delevering into the analytical path, by varying both volumetric fractions, following an algorithm based on successive aproximation method. Analytical signals assessed from the analog output of the spectrophotometer for each tentatives were converted to digital making use of an interface card, attached in the microcomputer main board. After each solutions handling cycles, the data collected were processed in order to decide about the next tentative to be carried out, obeying the settled binary search algorithm. The feasibility was ascertained by titrating solutions employing neutralization and complexation reactions. The time interval to perform this titration process employing binary search concept was about 3 minutes, consuming ca 2 cm3 of reagents solutions. No significant difference at 5 % probability level was observed by comparing of the results obtained applying this procedure with those produced by manual procedures.
14

Desenvolvimento de métodos e instrumentação para amostragem e determinação de algumas espécies relacionadas aos processos de acidificação da atmosfera / The development of methods and instrumentation for sampling and determination of certain species related to atmospheric acidification processes

Rocha, Flavio Roberto 27 June 2003 (has links)
A atmosfera, ao lado dos principais gases que a compõe, apresenta em menores concentrações milhares de compostos químicos (orgânicos e inorgânicos) distribuídos nas fases líquidas e gasosa ou no material particulado. Quando esses compostos encontrados no ar apresentam níveis de concentração que os tornam impróprios ou nocivos à saúde humana, aos animais ou vegetais e danosos aos materiais, são considerados poluentes atmosféricos. Neste trabalho, enfatizou-se o estabelecimento de métodos alternativos, eficientes e práticos, para a amostragem de várias espécies que participam dos processos de acidificação da atmosfera, assim corno o desenvolvimento de métodos analíticos baseados em técnicas eletroanalíticas em fluxo como a amperometria e a eletroforese capilar com detecção condutométrica sem contato. Devido a algumas limitações das técnicas de amostragem, explorou-se a alternativa de recorrer a tubos capilares com paredes microporosas, preenchidos com solução adequada à absorção das espécies em pauta, após sua difusão através dos poros da membrana hidrófoba. Assim, construiu-se um coletor por difusão utilizando-se tubo de Teflon&#174;, dentro do qual foi introduzido um feixe de tubos capilares porosos de polipropileno. A união desta técnica de amostragem com a determinação seletiva e quantitativa dos analitos por eletroforese capilar com detecção condutométrica (CE-CCD) possibilitou o desenvolvimento de métodos completos para as seguintes espécies: CH2O coletado em água deionizada, à freqüência de 1 amostra por hora, seguido de derivatização com HSO3- para determinação de fonnaldeído na forma de hidroximetanossulfonato (HMS); HCOOH e H3C2OOH- com o mesmo procedimento de coleta e separação por CE-CCD aplicado na detenninação de CH2O na forma de HMS; e NH3 - coletado em solução de HCl e determinado na forma de NH4+ por CE-CCD. Outra espécie de interesse ambiental é o H2O2, por participar de várias reações de oxidação tanto na fase gasosa corno na fase líquida da atmosfera, contribuindo assim para a acidez da atmosfera. A detenninação analítica do H2O2 foi feita por método FIA amperométrico com eletrodo de gota pendente de mercúrio, adaptando-se célula eletroquímica estacionária ao trabalho em fluxo. Duas formas de coleta de H2O2 na fase gasosa foram desenvolvidas e comparadas: . coleta por difusão - com fluxo de água deionizada pelos feixe de filamentos capilares; nesta aplicação, o feixe foi conectado diretamente à alça de amostragem do injetor, proporcionando determinações on-line\". . amostragem criogênica em dispositivo \"passivo\" - aproveitando o fato conhecido de que a razão H2O:H2O2 da fase gasosa se mantém praticamente inalterada na fase sólida (gelo coletado). Além das determinações de H2O2 na fase gasosa, o método FIA-Amperométrico foi utilizado, em trabalhos realizados em parceria com pesquisadores do IPEN, para determinação dessa espécie em efluentes e água de cultivo do microcrustáceo Daphnia similis após serem irradiados com feixes de elétrons. Paralelamente às pesquisas relacionadas a espécies gasosas, desenvolveu-se metodologia para a determinação de cátions e ânions majoritários em água de chuva, recorrendo à CE-CCD, de modo a oferecer uma alternativa à consagrada técnica da cromatografia de íons, demorada e onerosa. Os estudos iniciais da composição iônica da chuva foram feitos com coletas de água de chuva efetuadas no período de Abril/97 a Março/98. Nesse conjunto de amostras determinou-se as concentrações dos cátions (NH4+, Ca2+, K+ e Na+) e dos ânions (NO3-, SO42- e Cl-), além das usuais medições de pH e condutividade. A Eletroforese Capilar mostrou-se particularmente tàvorável para a determinação dos íons majoritários em água de chuva. Embora fugindo da área ambiental, desenvolveu-se metodologia para determinação de espécies de S(IV) em amostras de vinho, a partir de algumas adaptações de método amperométrico em fluxo desenvolvido no mestrado para análise de sulfito e HMS em água de chuva. Assim, desenvolveu-se três sistemas FIA-Amperométrico com eletrodo de gota pendente de mercúrio distintos, os quais foram utilizados para determinação de HSO3- livre e adutado (na forma de hidroxialcanossulfonatos) e SO2, com auxílio de uma unidade de difusão gasosa. / Alongside with its main components, the atmosphere contains trace amounts of thousands of chemical compounds (organic and inorganic) distributed in the liquid and gaseous phases, as well as in the particulate matter. These species can be considered pollutants when they are encountered at levels capable of generating adverse effects to humans, animals, plants or materials. The aim of this work was to establish alternative, efficient and practical methods for the sampling of several species encountered in the gaseous phase, as well as to develop analytical methods based on electroanalytical flow techniques, such as amperometry and capillary electrophoresis with contactless conductometric detection (CE-CCD). Due to some limitations in the existing sampling techniques, an altemative method based on the diffusion of the analytes through the microporous hydrophobic walls of capillary tube filled with an appropriate absorbent solution, was investigated. The collecting device was assembled using a Teflon&#174; tube wherein a bundle of porous capillary polypropylene tubes was introduced. The coupling of this sampling technique with the selective and quantitative determination of the species by capillary electrophoresis with contactless conductometric detection (CE-CCD) enabled the development of complete analytical protocols for the following species: i) CH2O - collected in deionized water at a frequency of 1 sample/h and derivatized with HSO3- for its determination as hydroxymethanesulfonate (HMS); ii) HCOOH and H3COOH - collected using the same sampling procedure and quantified upon separation by CE-CCD; and iii) NH3 - collected in a HCl solution and deterrnined as NH4+ form. Another species of environmental interest is H2O2, which contributes to the acidity of the atmosphere on account of its involvement in some oxidation process both in the gaseous and liquid phases. The deterrnination of the H2O2 Was carried out using a FIA amperometric method at the hanging mercury drop electrode, in a batch electrochemical cell adapted to function under tlowing conditions. Two sampling procedures for H2O2 in the gaseous phase were developed and compared: . collection by diffusion - from the air into a flow of deionized water within the bundle of capillary filaments, which were, in tum, connected to the sample loop in order to allow on-line deterrninations. · cryogenic, with a \"passive\" sampler - based on the well-known fact that the H2O:H2O2 ratio in the gaseous phase is practically maintained in the solid phase. In addition to these determinations in the gaseous phase and in a partnership with researchers of the IPEN, the FIA-Amperometric method was used for the quantification of H2O2 in effluent and in cultivation water of the microcrustacean Daphnia Similis after irradiation by MeV electron beams. In parallel to the related research, a methodology for the CE-CCD determination of majority cations and anions in rain water was developed. This was proposed as an altemarive method to well-established ion chromatography techniques. Initial studies on the ionic composition of rain were conducted on samples collected between April/97 and March/98, using an automatic collector previously developed. In this set of samples, the concentrations of cations (NH4+, Ca2+, K+ e Na+) and anions (NO3-, SO42- e Cl-) were determined, together with the usual measurements of pH and conductivity. Capillary electrophoresis tumed out to be particularly suitable for the determination of ions in rain water. Although strictly not environrnental in kind, a methodology for determination of S(IV) species in wine samples was implemented by adjusting a previously-developed flow-amperometric method for the analysis of sulfite and HMS in rain water. For this purpose, three distinct FIA-Amperometric systems using a gas diffusion device and the hanging mercury drop electrode were designed, assembled and used for the determination of HSO3- in the free and bound forms (as hydroxyaIkanesulfonates) and SO2.
15

Estudos eletroquímicos envolvendo eletrodos modificados por metaloporfirinas e aplicação na determinação de nitrato (NO3-) e nitrito (NO2-) / Electrochemical studies involving electrodes modified by metalloporphyrins and application in the determination of nitrate (NO3-) and nitrite (NO2-)

Rocha, José Roberto Caetano da 06 February 2001 (has links)
O presente trabalho inclui duas etapas da pesquisa. Na primeira fase do projeto, a oxidação eletroquímica do nitrito em eletrodo de carbono vítreo modificado com um filme obtido eletrostaticamente de Co-TRP/Zn-TPPS, foi investigada em pH 4,7. Um aumento de corrente foi detectado em 0,75V, cujo máximo foi proporcional à concentração do íons nitrito, exibindo uma dependência inversa com a espessura do filme. A velocidade de transferência de carga foi avaliada por cronoamperometria, sendo que a velocidade de difusão da carga eletroquímica através do filme é mais alta do que a velodicade de difusão do íon em solução. O processo catalítico envolvendo a oxidação do íon nitrito no filme de pares de depósitos alternados foi também investigado com as técnicas da voltametria cíclica e de disco rotativo. Em concentrações relativamente baixas de substrato, o processo mediado foi tratado como um sub-caso, SR, na notação de Saveant, permitindo o cálculo da constante de velocidade para a reação de troca na interface filme-solução, sendo que tal valor foi estimado em 3,4x103 dm3 mol-1 s-1. Na segunda parte da investigação, a potencialidade analítica do eletrodo modificado foi confirmada por experimentos de injeção em fluxo usando solução carregadora tampão pH 4,7. Devido à atividade catalítica da camada imobilizada, a determinação de nitrito foi realizada em potencial menos positivo do que aqueles obtidos em eletrodos polidos (0,75 V vs. Ag/AgCl) e os dados obtidos demostraram o melhor desempenho do eletrodo modificado, indicando excelente repetibilidade e maior sensibilidade. Na condição experimental otimizada, o nitrito foi determinado na configuração FIA com limite de detecção de 0,1 &#181mol L-1 e a faixa analítica de aplicabilidade do método foi de 1 a 1000 &#181;mol L-1. Nitrato também foi quantificado após sua redução estequiométrica a nitrito pela passagem da solução através da coluna de cádmio/cobre. Ambos analitos foram quantificados em água mineral e amostras de saliva e os resultados foram concordantes com aqueles obtidos usando método oficial. / This present work includes two research steps. ln the first step the electrochemical oxidation on nitrite on a glassy carbon disc electrode, modified with an electrostatically assembled film of tetraruthenated cobalt porphyrin/(meso-tetra(4-sulphonatephenyl)porphyrinate zinc(II), was investigated at pH = 4.7. A current enhancement was observed by using the modified electrode, the signal being proportional to the concentration of nitrite ions and exhibiting an inverse dependence with the film thickness. The charge transfer rate was evaluated by chronoamperometry, showing that the rate of diffusion of electrochemical charge through the film is higher than the rate of diffusion of substrates in solution. The catalytic process involving the oxidation of the nitrite ions at the bilayered film was also investigated based on cyclic and rotating disc voltammetry. At relatively low substrate concentrations the mediated process has been dealt with in terms of the SR sub-case in Saveant\'s notation, allowing the calculation of the rate constant for the cross-exchange reaction at the film-solution interface as 3.4x103 dm3 mol-1 s-1. In the second part the analytical potentiality of the modified electrode was studied by flow injection experiments carried out by using a pH 4.7 buffer as carrier solution. Owing to the catalytic activity of the immobilized layer, the determination of nitrite was performed at less positive potentials (0.75 V versus Ag/AgCl) and the data obtained showed a better performance indicated by both an excellent repeatability and increased sensitivity. At the optimized experimental condition, nitrite was determined in the FIA configuration with a limit of detection of 0.1 &#181;mol L-1. Nitrate was also quantified after its stoichiometric reduction to nitrite by passing the solution through a cadmium/copper column. Both analytes were quantified in mineral water and saliva samples and the results were in agreement with the ones obtained by using an official method.
16

Técnicas modernas de separação e análise de extratos vegetais / Modern techniques of separation and analysis of plant extracts

Fonseca, Fabiana Novais 16 January 2002 (has links)
O uso das plantas medicinais confunde-se com a história do ser vivente. Desde a idade da pedra até meados do século XX elas constituíram a principal fonte medicamentosa para a nossa sociedade. Hoje o mercado de fitoterápicos e fitocosméticos vem movimentando bilhões de dólares a cada ano. Apesar de possuir representantes de cerca de 70% de toda a flora mundial, historicamente o Brasil não apresenta tradição cientifica no uso de medicamentos vegetais, sendo a fitoterapia praticada principalmente por caboclos, curandeiros e xamãs. Apenas recentemente, com a \"biopirataria\" e com o crescimento constante do interesse de grandes multinacionais na Amazônia e Mata Atlântica é que está se observando uma movimentação nacional no sentido da legalização e controle de fitoterápicos e da flora Nacional. Neste contexto o Governo Brasileiro formulou uma Resolução em Fevereiro de 2000, regulamentando a produção de fitoterápicos no País, a qual preconiza o controle de qualidade, tanto da matéria-prima quanto do produto acabado. O presente trabalho propõe metodologias para análise de compostos fenólicos (cumarinas, fenilpropanóides e f1avonóides) em extratos metanólico, glicólico e hidroalcoólico de camomila (Matricaria recutita L.) através das técnicas de cromatografia líquida de alta eficiência (HPLC), cromatografia líquida capilar (&#181;HPLC), eletroforese capilar de zona livre (FSCE), cromatografia eletrocinética micelar (MEKC) e eletrocromatografia capilar (CEC). O desempenho de cada técnica foi avaliado comparativamente em termos de disponibilidade e tipo de coluna, número de pratos, fator de retenção, seletividade, resolução, tempo e custo de análise. Um estudo de pré-purificação dos extratos foi feito utilizando extração em fase sólida (ODS e HLB) e RMN 1H para acompanhamento das substâncias invisíveis no UV. Propõe-se ainda um protocolo para empacotamento de colunas capilares para &#181;HPLC e CEC. Os extratos foram doseados quanto ao teor de apigenina livre e total, utilizando metodologia validada segundo a USP 24. / The use of medicinal plants for the cure of ailments is as old as mankind. From the Stone Ages throughout the first part of last century, they were the main sources of medicines for our society. Today, the commercial markets are investing billions of dollars every year into the research and development of medicinal plants. Despite having about 70% of the whole world flora, historically Brazil does not have a scientific tradition in the use of herbal medicines. Until very recently, mainly mestizos, healers and xamãs have practiced phytotherapy. But now, with the growth of the interest of pharmaceutical companies in the Amazonian and Atlantic rain forests, there has been a national movement in the way of legalization and control of the National flora. In this context, the Brazilian Government formulated a resolution in February 2000, regulating the production of phytomedicines in this country, which requires the quality control of such products. The present work proposes methodologies for the analysis of the phenolic substances (coumarins, phenylpropanoids and flavonoids) present in methanolic, glycolic and ethanolic extracts of chamomile (Matricaria recutita L.) by the use of High Performance Liquid Chromatography (HPLC), micro Liquid Chromatography (&#181HPLC). Free Solution Capillary Electrophoresis (FSCE), Micellar Electroknetic Chromatography (MEKC) and Capillary Electrochromatography (CEC). These techniques were evaluated comparatively in terms of column performance, plate number, retention factor, selectivity, resolution, time and analysis cost. Pre-purification studies using Solid Phase Extraction (SPE) cartridges (ODS and HLB Oassis) were also carried out and the collected fractions were analyzed by FSCE and RMN 1H. This fatter technique was applied in order to monitor the presence of fat acids on the eluates. A packing procedure for micro columns to use in &#181;HPLC and in CEC is also proposed. Methanolic, glycolic and ethanolic extracts of Matricaria recutita L. were standardized relatively to the total apigenin contents and the CE methodology was thoroughly validated following the United States Pharmacopoea 24 protocol.
17

Dissolução química parcial \"on line\" de aço inoxidável seguida de determinação de Cr, Mn e Ni por espectrometria de emissão ótica com plasma indutivamente acoplado (ICP-OES) / Partial on-line chemical dissolution of stainless steel followed by determination of Cr, Mn and Ni by inductively coupled plasma optical emission spectrometry (ICP-OES)

Capri, Maria da Rosa 08 February 2001 (has links)
O objetivo deste trabalho foi o desenvolvimento de metodologia analítica versátil e rápida para a determinação de Cr, Mn e Ni em aços martensíticos e austeníticos, através do processo de dissolução química parcial em sistema de injeção em fluxo acoplado ao Espectrômetro de Emissão Ótica acoplado indutivamente (ICP-OES). O procedimento, também priorizou menor manipulação de amostra e consumo de reagentes. A solução extratora, HNO3 e HCI 7,0 mol L-1 e 6,0 mol L-1 respectivamente 1:1 v/v foi utilizada para a dissolução química parcial dos aços inoxidáveis. A quantificação dos metais dissolvidos foi feita utilizando-se o método da somatória, que relaciona a concentração de um elemento individual com a somatória dos elementos determinados, segundo a fórmula: i% = Ci /Ct x 100, onde Ci é a concentração do elemento i e Ct é a soma das concentrações de todos elementos determinados. Os resultados não apresentaram diferença significativa em um nível de confiança de 95% com os valores certificados das amostras de referência e com os valores da dissolução total assistida por microondas. O procedimento apresentou freqüência analítica de 20 determinações por hora. / The objective of this work was the development of a versatile and fast analytical methodology for the determination of Cr, Mn, and Ni in martensitic and austenitic steels, through on-line partial chemical dissolution using a flow injection system coupled to an ICP-OES. The procedure also aimed the smallest sample manipulation and reagents consumption. The extractor solution, 7.0 mol L-1 HNO3 and 6.0 mol L-1 HCI 1:1 v/v, was used to the on-line partial chemical dissolution of the stainless steels. The quantification of the dissolved metals was made using a method, that relate the concentration of an individual element with the sum of all elements concentrations, applying the formula: i% = Ci /Ct x 100, where Ci is the concentration of the element i and Ct is the sum of the concentration of all elements determined. No significant difference has been present by the results, at a confidence level of 95%, with the certified values of the reference materials and with the total dissolution values obtained by microwave - assisted sample pretreatment. The procedure presented analytic frequency of 20 determinations per hour.
18

Determinação de nutrientes e contaminantes Inorgânicos em café solúvel por espectrometria de emissão atômica com plasma de argônio induzido (ICP-AES) / Determination of nutrients and inorganic contaminants in soluble coffee by atomic emission spectrometry with inductively-coupled plasma (ICP-AES)

Santos, Eder José dos 07 April 1999 (has links)
A produção industrial do café solúvel brasileiro destina-se, na sua maior parte, ao mercado externo, constituindo-se em um importante ítem de exportação do país. O objetivo do presente trabalho foi o desenvolvimento e aprimoramento de métodos de análise química adequados à investigação de componentes inorgânicos em café solúvel. Inicialmente foi definido o método de mineralização das amostras através da avaliação de 6 procedimentos diferentes, classificados em 3 classes: (I) microondas focalizado; (II) via úmida convencional e (III) sistema sob pressão em frascos de decomposição com tampas (bombas de teflon). As determinações dos nutrientes e contaminantes inorgânicos: Na, K, Mg, Al, P, S, Ca, Mn, Fe, Ni, Cu, Zn, Cd, Sb, Pb, Cr, Sn, As, Se e Hg, após a utilização do procedimento de mineralização que emprega o sistema de microondas focalizado com os reagentes HNO3 e H2O2, foram realizadas por espectrometria de emissão atômica com plasma induzido, ICP-AES (da nomenclatura inglesa Inductively Coupled Plasma-Atomic Emission Spectrometry). Interferências de matriz e/ou espectrais foram detectadas nas determinações de Pb, Cr, Sn, As, Se e Hg. No caso do Sn, optou-se pela correção da radiação de fundo através do software do equipamento, pois outras linhas de emissão deste analito eram menos sensíveis e igualmente sujeitas a interferências espectrais. Para o Pb e Cr a escolha de comprimentos de ondas alternativos eliminou os problemas de interferências espectrais devido à matriz das amostras. A aplicação das técnicas de geração de hidretos para o As e Se e a geração de vapor frio para o Hg, possibilitaram as determinações destes analitos nas amostras de café solúvel, aumentando a sensibilidade das análises. Os resultados obtidos para os teores dos nutrientes e contaminantes inorgânicos em 21 amostras de café solúvel disponíveis no mercado brasileiro, foram aceitáveis para o consumo humano, tanto no aspecto nutricional como toxicológico, com exceção de uma amostra com teor de Cr igual a 0,52 ± 0,02 mgKg-1, acima do permitido pela legislação brasileira que fixa o valor máximo de 0,10 mgKg-1. A aplicação de técnicas estatísticas, análise de clusters hierárquicos e componentes principais aos resultados obtidos, possibilitaram investigar a variabilidade das composições minerais e classificar grupos de amostras similares. O emprego da técnica instrumental ICP-AES através do sistema de nebulização convencional e a utilização do sistema de geração de hidretos e vapor frio, mostraram-se adequados para as determinações dos nutrientes e contaminantes inorgânicos em café solúvel, uma vez que níveis de precisão e exatidão aceitáveis foram obtidos. / The production of Brazilian soluble coffee is almost entirely destined for exporting. Therefore, the objective of this work was the development and the establishment of appropriate methods of chemical analysis of inorganic components in soluble coffee. Firstly, the appropriate digestion procedure for soluble coffee samples was defined through the evaluation of six different digestion techniques that were classified into three groups: (I) focused microwave system, (II) conventional wet digestion and (III) pressure digestion system in teflon bombs. The determinations of nutrients and toxic elements: Na, K, Mg, Al, P, S, Ca, Mn, Fe, Ni, Cu, Zn, Cd, Sb, Pb, Cr, Sn, As, Se, and Hg after the utilization of the focused microwave system with HNO3 and H2O2 reagents, were made by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) technique. Matrix and spectral interferences were detected in the determination of Pb, Cr, Sn, As, Se and Hg. Correction of the background enhancement by the equipment software was made in the determination of Sn, as other analytical lines were unsuitable for this application. For Pb and Cr, the choice of other analytical lines eliminated the problem of matrix and spectral interferences. The application of the hydride generation technique for As and Se and cold atomic vapour with ICP-AES for Hg, were suitable methods to determine these analytes in soluble coffee samples with increased sensitivity of the analysis. The results obtained of nutrients and toxic elements in twenty-one samples of soluble coffee collected from Brazilian market were acceptable to human consumption at nutritional and toxic level with exception of a sample with 0,52 ± 0,02 mgKg-1 of Cr, above the value specified in Brazilian Food Legislation, that fixes the maximum Cr contend in 0,10 mgKg-1. The aplication of statistical techniques analysis of principal components and the hierarchical cluster on the results of mineral compositions, enabled to investigate the variability in the composition and to classify groups of similar samples. The application of the ICP-AES technique using the conventional pneumatic nebulization system, the hydride generation technique and the cold vapour for Hg were suitable to determine the nutrients and toxic elements in soluble coffee, as they provided acceptable results indicating accuracy and precision.
19

Estudos eletroquímicos envolvendo eletrodos modificados por metaloporfirinas e aplicação na determinação de nitrato (NO3-) e nitrito (NO2-) / Electrochemical studies involving electrodes modified by metalloporphyrins and application in the determination of nitrate (NO3-) and nitrite (NO2-)

José Roberto Caetano da Rocha 06 February 2001 (has links)
O presente trabalho inclui duas etapas da pesquisa. Na primeira fase do projeto, a oxidação eletroquímica do nitrito em eletrodo de carbono vítreo modificado com um filme obtido eletrostaticamente de Co-TRP/Zn-TPPS, foi investigada em pH 4,7. Um aumento de corrente foi detectado em 0,75V, cujo máximo foi proporcional à concentração do íons nitrito, exibindo uma dependência inversa com a espessura do filme. A velocidade de transferência de carga foi avaliada por cronoamperometria, sendo que a velocidade de difusão da carga eletroquímica através do filme é mais alta do que a velodicade de difusão do íon em solução. O processo catalítico envolvendo a oxidação do íon nitrito no filme de pares de depósitos alternados foi também investigado com as técnicas da voltametria cíclica e de disco rotativo. Em concentrações relativamente baixas de substrato, o processo mediado foi tratado como um sub-caso, SR, na notação de Saveant, permitindo o cálculo da constante de velocidade para a reação de troca na interface filme-solução, sendo que tal valor foi estimado em 3,4x103 dm3 mol-1 s-1. Na segunda parte da investigação, a potencialidade analítica do eletrodo modificado foi confirmada por experimentos de injeção em fluxo usando solução carregadora tampão pH 4,7. Devido à atividade catalítica da camada imobilizada, a determinação de nitrito foi realizada em potencial menos positivo do que aqueles obtidos em eletrodos polidos (0,75 V vs. Ag/AgCl) e os dados obtidos demostraram o melhor desempenho do eletrodo modificado, indicando excelente repetibilidade e maior sensibilidade. Na condição experimental otimizada, o nitrito foi determinado na configuração FIA com limite de detecção de 0,1 &#181mol L-1 e a faixa analítica de aplicabilidade do método foi de 1 a 1000 &#181;mol L-1. Nitrato também foi quantificado após sua redução estequiométrica a nitrito pela passagem da solução através da coluna de cádmio/cobre. Ambos analitos foram quantificados em água mineral e amostras de saliva e os resultados foram concordantes com aqueles obtidos usando método oficial. / This present work includes two research steps. ln the first step the electrochemical oxidation on nitrite on a glassy carbon disc electrode, modified with an electrostatically assembled film of tetraruthenated cobalt porphyrin/(meso-tetra(4-sulphonatephenyl)porphyrinate zinc(II), was investigated at pH = 4.7. A current enhancement was observed by using the modified electrode, the signal being proportional to the concentration of nitrite ions and exhibiting an inverse dependence with the film thickness. The charge transfer rate was evaluated by chronoamperometry, showing that the rate of diffusion of electrochemical charge through the film is higher than the rate of diffusion of substrates in solution. The catalytic process involving the oxidation of the nitrite ions at the bilayered film was also investigated based on cyclic and rotating disc voltammetry. At relatively low substrate concentrations the mediated process has been dealt with in terms of the SR sub-case in Saveant\'s notation, allowing the calculation of the rate constant for the cross-exchange reaction at the film-solution interface as 3.4x103 dm3 mol-1 s-1. In the second part the analytical potentiality of the modified electrode was studied by flow injection experiments carried out by using a pH 4.7 buffer as carrier solution. Owing to the catalytic activity of the immobilized layer, the determination of nitrite was performed at less positive potentials (0.75 V versus Ag/AgCl) and the data obtained showed a better performance indicated by both an excellent repeatability and increased sensitivity. At the optimized experimental condition, nitrite was determined in the FIA configuration with a limit of detection of 0.1 &#181;mol L-1. Nitrate was also quantified after its stoichiometric reduction to nitrite by passing the solution through a cadmium/copper column. Both analytes were quantified in mineral water and saliva samples and the results were in agreement with the ones obtained by using an official method.
20

Determinação de nutrientes e contaminantes Inorgânicos em café solúvel por espectrometria de emissão atômica com plasma de argônio induzido (ICP-AES) / Determination of nutrients and inorganic contaminants in soluble coffee by atomic emission spectrometry with inductively-coupled plasma (ICP-AES)

Eder José dos Santos 07 April 1999 (has links)
A produção industrial do café solúvel brasileiro destina-se, na sua maior parte, ao mercado externo, constituindo-se em um importante ítem de exportação do país. O objetivo do presente trabalho foi o desenvolvimento e aprimoramento de métodos de análise química adequados à investigação de componentes inorgânicos em café solúvel. Inicialmente foi definido o método de mineralização das amostras através da avaliação de 6 procedimentos diferentes, classificados em 3 classes: (I) microondas focalizado; (II) via úmida convencional e (III) sistema sob pressão em frascos de decomposição com tampas (bombas de teflon). As determinações dos nutrientes e contaminantes inorgânicos: Na, K, Mg, Al, P, S, Ca, Mn, Fe, Ni, Cu, Zn, Cd, Sb, Pb, Cr, Sn, As, Se e Hg, após a utilização do procedimento de mineralização que emprega o sistema de microondas focalizado com os reagentes HNO3 e H2O2, foram realizadas por espectrometria de emissão atômica com plasma induzido, ICP-AES (da nomenclatura inglesa Inductively Coupled Plasma-Atomic Emission Spectrometry). Interferências de matriz e/ou espectrais foram detectadas nas determinações de Pb, Cr, Sn, As, Se e Hg. No caso do Sn, optou-se pela correção da radiação de fundo através do software do equipamento, pois outras linhas de emissão deste analito eram menos sensíveis e igualmente sujeitas a interferências espectrais. Para o Pb e Cr a escolha de comprimentos de ondas alternativos eliminou os problemas de interferências espectrais devido à matriz das amostras. A aplicação das técnicas de geração de hidretos para o As e Se e a geração de vapor frio para o Hg, possibilitaram as determinações destes analitos nas amostras de café solúvel, aumentando a sensibilidade das análises. Os resultados obtidos para os teores dos nutrientes e contaminantes inorgânicos em 21 amostras de café solúvel disponíveis no mercado brasileiro, foram aceitáveis para o consumo humano, tanto no aspecto nutricional como toxicológico, com exceção de uma amostra com teor de Cr igual a 0,52 ± 0,02 mgKg-1, acima do permitido pela legislação brasileira que fixa o valor máximo de 0,10 mgKg-1. A aplicação de técnicas estatísticas, análise de clusters hierárquicos e componentes principais aos resultados obtidos, possibilitaram investigar a variabilidade das composições minerais e classificar grupos de amostras similares. O emprego da técnica instrumental ICP-AES através do sistema de nebulização convencional e a utilização do sistema de geração de hidretos e vapor frio, mostraram-se adequados para as determinações dos nutrientes e contaminantes inorgânicos em café solúvel, uma vez que níveis de precisão e exatidão aceitáveis foram obtidos. / The production of Brazilian soluble coffee is almost entirely destined for exporting. Therefore, the objective of this work was the development and the establishment of appropriate methods of chemical analysis of inorganic components in soluble coffee. Firstly, the appropriate digestion procedure for soluble coffee samples was defined through the evaluation of six different digestion techniques that were classified into three groups: (I) focused microwave system, (II) conventional wet digestion and (III) pressure digestion system in teflon bombs. The determinations of nutrients and toxic elements: Na, K, Mg, Al, P, S, Ca, Mn, Fe, Ni, Cu, Zn, Cd, Sb, Pb, Cr, Sn, As, Se, and Hg after the utilization of the focused microwave system with HNO3 and H2O2 reagents, were made by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) technique. Matrix and spectral interferences were detected in the determination of Pb, Cr, Sn, As, Se and Hg. Correction of the background enhancement by the equipment software was made in the determination of Sn, as other analytical lines were unsuitable for this application. For Pb and Cr, the choice of other analytical lines eliminated the problem of matrix and spectral interferences. The application of the hydride generation technique for As and Se and cold atomic vapour with ICP-AES for Hg, were suitable methods to determine these analytes in soluble coffee samples with increased sensitivity of the analysis. The results obtained of nutrients and toxic elements in twenty-one samples of soluble coffee collected from Brazilian market were acceptable to human consumption at nutritional and toxic level with exception of a sample with 0,52 ± 0,02 mgKg-1 of Cr, above the value specified in Brazilian Food Legislation, that fixes the maximum Cr contend in 0,10 mgKg-1. The aplication of statistical techniques analysis of principal components and the hierarchical cluster on the results of mineral compositions, enabled to investigate the variability in the composition and to classify groups of similar samples. The application of the ICP-AES technique using the conventional pneumatic nebulization system, the hydride generation technique and the cold vapour for Hg were suitable to determine the nutrients and toxic elements in soluble coffee, as they provided acceptable results indicating accuracy and precision.

Page generated in 0.1572 seconds