Spelling suggestions: "subject:"titulação"" "subject:"rotulação""
1 |
Titulação automática com detecção digital RGB e uso de seringa microvolumétricaBernar, Lucas Pinto 13 July 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2017. / Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2017-10-02T12:14:05Z
No. of bitstreams: 1
2017_LucasPintoBernar.pdf: 7249506 bytes, checksum: 3f1aff3dc6f8b10cf83fa7951d607348 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-10-04T15:27:06Z (GMT) No. of bitstreams: 1
2017_LucasPintoBernar.pdf: 7249506 bytes, checksum: 3f1aff3dc6f8b10cf83fa7951d607348 (MD5) / Made available in DSpace on 2017-10-04T15:27:06Z (GMT). No. of bitstreams: 1
2017_LucasPintoBernar.pdf: 7249506 bytes, checksum: 3f1aff3dc6f8b10cf83fa7951d607348 (MD5) / No presente trabalho, o sinal RGB de imagens digitais foi utilizado para construção de um titulador automático capaz de realizar um número variado de titulações. O equipamento construído pode ser uma alternativa a outros procedimentos devido à sua precisão e capacidade de realizar várias análises diferentes com o mesmo instrumento de detecção do ponto final. Para isso, como um primeiro passo, imagens digitais de 5 titulações foram gravadas por uma câmera webcam comum em ensaios com amostras reais feitos utilizando uma bomba-seringa de elevada precisão controlada por um computador. Curvas de titulação foram construídas com seu sinal RGB e analisadas por meio de várias transformações matemáticas (primeiras, segundas derivadas e suas combinações) para gerar algoritmos de detecção automática do ponto final. Estes algoritmos foram testados através da medição do erro de titulação de soluções padrão. As titulações analisadas foram as determinações de ácido acético em vinagres com NaOH, dureza de água mineral com EDTA, cloretos em águas de coco com Nitrato de Prata, ácido ascórbico em comprimidos de vitamina C com iodo e açúcares redutores em amostras de vinhos e cervejas com tiossulfato de sódio. Para os procedimentos considerados, de neutralização, complexação, precipitação, oxi-redução e açúcares redutores foram obtidos, respectivamente, 0,10%, 1,16%, 0% , 0% e -0,67% de erro relativo à procedimentos clássicos de titulação. Os testes para obtenção dos algoritmos foram comparados aos métodos clássicos e verificou-se que não há diferenças significativas em um intervalo de confiança de 95% e o sinal RGB é suficientemente exato para determinar o ponto final das titulações consideradas. Esta configuração, aliada à natureza multivariada do sinal RGB, traz uma poderosa e barata forma de análise quantitativa. / In this assay, the RGB signal of digital images is used to craft a versatile automatic titrator. In order to achieve this, digital images of 5 titrations of real samples were recorded by a commom webcam. The titrations were conducted using a syringe-pump controlled by a personal computer. Titration curves are drawn with RGB signal and analysed by some mathematical transformations (first, second derivatives and combinations of it) to generate algorithms for automatic detection of titration end-point. This are evaluated by determining the titration errors of standard solutions. The titrations studied were the determination of acetic acid in vinegars with NaOH, mineral water hardness with EDTA, chlorides in coconut water with silver nitrate, ascorbic acid in vitamin C tablets with iodide and reducing sugars in wines and beer samples with Na2S2O3 .To the procedures involved, neutralization, complexation, precipitation, redox and reducing sugars were obtained, 0,10%, 1,16%, 0%, 0% e 0,67% of errors, respectively. Those tests were compared to classical methods and no significant differences were found in a 95% confidence level. The metodology developed will be applied to a smartphone and every step of the method will be conducted by Bluetooth communication. This configuration, allied to the multivariate nature of the RGB signal, brings a powerful and unexpensive way of quantitative analysis.
|
2 |
A formação continuada Stricto Sensu: sentidos constuídos pelos docentes do ensino superior privado face às exigências legaisSilva Cunha, Kátia January 2005 (has links)
Made available in DSpace on 2014-06-12T17:20:27Z (GMT). No. of bitstreams: 1
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2005 / Essa pesquisa sobre a Formação Continuada Stricto Sensu: sentidos
construídos pelos docentes do ensino superior privado face às exigências
legais, tem como objetivo compreender os sentidos que os professores da
educação superior, no âmbito do ensino privado, estabelecem sobre a
formação do docente em cursos de pós-graduação stricto sensu. Essa temática
se insere no debate sobre a formação do professor presente nas produções
nacionais e estrangeiras como, Cunha, 1998; Pimenta, 1999; Pimenta e
Anastasiou, 2002; Zabalza, 2004; Nóvoa, 1995; Cachapuz, 2002; entre outros.
Para tanto estabelecemos como percurso teórico-metodológico o referencial da
análise do discurso, que apresenta Orlandi, na linha francesa. A escolha por
esse instrumento tem relação com nosso objeto de estudo que busca o sentido
da formação no discurso que vai além do dito, do explícito; exige uma
compreensão do contexto onde este foi produzido e uma desconstrução dos
discursos existentes na busca dos sentidos, que estão presentes no silêncio.
Como resultados encontramos: o discurso da titulação presente no âmbito
oficial legal onde há um silenciamento quanto à identidade profissional,
socialmente construída nas práticas que traz uma marca de distinção e de
diferenciação profissional em relação a outros grupos profissionais e o discurso
da formação, que se materializa como parte do processo de profissionalização
na reflexão das práticas sociais e construção dos saberes profissionais
|
3 |
A formação continuada Stricto Sensu: sentidos constuídos pelos docentes do ensino superior privado face às exigências legaisSilva Cunha, Kátia January 2005 (has links)
Made available in DSpace on 2014-06-12T17:23:14Z (GMT). No. of bitstreams: 2
arquivo8343_1.pdf: 627262 bytes, checksum: a4e441750e313be44ce66a67e5bf9d33 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2005 / Essa pesquisa sobre a Formação Continuada Stricto Sensu: sentidos
construídos pelos docentes do ensino superior privado face às exigências
legais, tem como objetivo compreender os sentidos que os professores da
educação superior, no âmbito do ensino privado, estabelecem sobre a
formação do docente em cursos de pós-graduação stricto sensu. Essa temática
se insere no debate sobre a formação do professor presente nas produções
nacionais e estrangeiras como, Cunha, 1998; Pimenta, 1999; Pimenta e
Anastasiou, 2002; Zabalza, 2004; Nóvoa, 1995; Cachapuz, 2002; entre outros.
Para tanto estabelecemos como percurso teórico-metodológico o referencial da
análise do discurso, que apresenta Orlandi, na linha francesa. A escolha por
esse instrumento tem relação com nosso objeto de estudo que busca o sentido
da formação no discurso que vai além do dito, do explícito; exige uma
compreensão do contexto onde este foi produzido e uma desconstrução dos
discursos existentes na busca dos sentidos, que estão presentes no silêncio.
Como resultados encontramos: o discurso da titulação presente no âmbito
oficial legal onde há um silenciamento quanto à identidade profissional,
socialmente construída nas práticas que traz uma marca de distinção e de
diferenciação profissional em relação a outros grupos profissionais e o discurso
da formação, que se materializa como parte do processo de profissionalização
na reflexão das práticas sociais e construção dos saberes profissionais
|
4 |
Titulações potenciométricas de cátions metálicos tendo como eletrodo indicador o sistema Cu/CuY2- / Potentiometric titrations of metallic cations with edta Using the cu/cuy2- system as indicator electrodeSilva, Paulo Henrique Pereira da 27 July 2007 (has links)
Made available in DSpace on 2016-06-02T20:36:20Z (GMT). No. of bitstreams: 1
1915.pdf: 869538 bytes, checksum: b9fcf9bcdb8ec116cd5fad0e482efe72 (MD5)
Previous issue date: 2007-07-27 / Universidade Federal de Sao Carlos / In this work a Cu/CuY2- indicator system was used to carry out potentiometric titrations of Cu2+, Co2+, Cd2+, Zn2+ and Mn2+ ions with EDTA solution. A copper wire with 8.32 cm2 of superficial area was used as an indicator electrode. The CuY2- complex was synthesized by reaction between cupric oxide (CuO) and EDTA standard solution (H2Y2-) at a temperature of 85 oC. The titrations were performed in the presence of small concentration of the CuY2- complex. The Cu2+, Co2+, Cd2+ and Zn2+ ions were titrated in sodium acetate buffer solution (pH 4.80) and Mn2+ in TRIS-HCl buffer solution (pH 8.90). A modification in a conventional method for titration of metallic cations with EDTA solutions was performed to improve the response of the system. The modification includes addition of buffer species to the titrant solution. The buffer specie used to prepare solutions was sodium acetate. The influence of the concentration of CuY2- added in the titration performance was investigated and a relation of nM2+/nCuY2- equal or greater than 5 should be used for a better response. During this work other studies were performed, such as the method to obtain carbonate-free sodium and potassium hydroxides solutions as well as the method for the standardization of EDTA solid reagent, Na2H2Y, to employing as secondary standard in the directly preparation of EDTA solution. / Neste trabalho foram realizadas titulações potenciométricas dos íons Cu2+, Co2+, Cd2+, Zn2+ e Mn2+ com EDTA utilizando um sistema indicador de Cu/CuY2-. O eletrodo indicador utilizado foi um fio de cobre com área superficial de aproximadamente 8,32 cm2 em meio contendo CuY2-. A síntese do complexo CuY2- foi baseada na reação entre óxido cúprico, CuO e solução padrão de EDTA, H2Y2- mantendo aquecimento de 85 oC. As titulações foram realizadas na presença de pequena quantidade de complexo CuY2-, sendo que os íons Cu2+, Co2+, Cd2+ e Zn2+ foram titulados em meio de tampão acetato pH 4,80 e os íons Mn2+ em meio de tampão TRIS-HCl pH 8,90. Uma mudança na metodologia original foi realizada, na qual os cátions metálicos estudados foram titulados com soluções de EDTA autotamponantes, isto é, titulantes que apresentam espécies tampão em sua composição. A espécie tampão utilizada no preparo das soluções foi o acetato. A influência da quantidade de complexo CuY2- adicionado durante as titulações também foi estudado, concluindo que a relação nM2+/nCuY2- deve ser maior ou igual a 5. Durante o desenvolvimento do trabalho, foram propostos também um novo método para o preparo de soluções de hidróxido de sódio e potássio livre de íons carbonato (CO3 2-) como também, uma metodologia para a padronização do sólido di-sódico de EDTA, Na2H2Y, permitindo assim o emprego deste sólido como padrão secundário no preparo imediato de suas respectivas soluções.
|
5 |
Terra de mulher: as contradições que permeiam as relações de gênero e a titulação conjunta da terra no âmbito da agricultura familiarValéria Batista Francelino da Silva, Adiliane 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T23:13:24Z (GMT). No. of bitstreams: 2
arquivo2532_1.pdf: 6745360 bytes, checksum: f1a3843c220acdab27b463f1b820fe7f (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A presente dissertação trata dos avanços e limites do direito à titulação conjunta da
terra por parte das trabalhadoras rurais, a partir de um estudo das relações de gênero e
do difícil e desigual acesso à terra entre homens e mulheres no âmbito da agricultura
familiar. Nossa investigação girou em torno da contradição existente entre o
reconhecimento formal deste direito por parte Estado brasileiro e a efetivação real do
acesso à terra, aos programas de reforma agrária e às demais políticas sociais numa
ordem capitalista e patriarcal. Por isso, consideramos imprescindível uma análise das
condições de trabalho e vida da mulher no âmbito da organização da produção familiar,
investigando como se processam as atividades produtivas e as reprodutivas nas
relações familiares e como se dá o acesso às políticas voltadas para as trabalhadoras
rurais no processo de construção de visibilidade e valorização do seu trabalho.
Constatou-se que, mesmo com a garantia do direito à titulação conjunta da terra, essas
trabalhadoras ainda vivenciam condições sociais, econômicas, políticas e culturais
desiguais em relação aos homens, expressando as desigualdades de gênero presentes
no cotidiano do assentamento em relação ao trabalho produtivo e reprodutivo, à
participação política e ao acesso a bens e serviços. Assim, fica claro que a existência
de políticas públicas e da legislação é importante, mas não suficiente para eliminar as
enormes desigualdades entre homens e mulheres fundamentada na divisão sexual do
trabalho, a qual, por sua vez, tem sido estruturante na organização de produção familiar
implementada pelo programa de reforma agrária brasileiro
|
6 |
Aperfeiçoamento de métodos para a determinação de componentes ácidos e básicos em amostras de água de chuva / Enhancement of methods for the determination of acid and alkaline compounds in rainwater samplesCoelho, Lucia Helena Gomes 14 April 2005 (has links)
O estudo da variação da composição atmosférica contribui para a compreensão dos efeitos das emissões antrópicas sobre a troposfera. A análise química da água de chuva assume importância neste contexto, uma vez que a precipitação úmida constitui um excelente meio de remoção de muitos poluentes da atmosfera. O aumento de acidez das chuvas, em várias partes do planeta, tem sido associado, predominantemente, à presença de ácidos fortes como o sulfúrico e nítrico, e ácidos orgânicos como acético e fórmico, originados pela oxidação de compostos de enxofre, nitrogênio e carbono, respectivamente. Dando continuidade a pesquisas anteriores sobre deposição úmida realizadas no IQ-USP, no presente trabalho buscou-se extrair mais informações de titulações potenciométricas e condutométricas de água de chuva, mediante aperfeiçoamento dos métodos de cálculo, com recursos quimiométricos modernos, de modo a complementar as medidas de pH e condutividade convencionais. As concentrações de espécies ácidas ou básicas nas amostras de água de chuva são da ordem de 10-5 mol L-1, muito abaixo das concentrações empregadas na prática cotidiana das titulações potenciométricas (tipicamente, no intervalo de 10-1 a 10-3 mol L-1). Dessa forma, propôs-se o uso de um método de regressão não linear (RNL) multiparamétrica, baseado no método de Levenberg-Marquardt, para a análise de dados potenciométricos (TP-RNL) após procedimento de transposição de coordenadas das curvas de titulação. Ao lado das determinações das concentrações dos analitos, pôde-se estimar ou refinar as constantes de protonação das bases de Brönsted presentes. Para tanto, procedeu-se ao ajuste por RNL das concentrações e/ou das constantes de protonação das bases presentes, de modo a minimizar o quadrado dos desvios entre os valores experimentais e os calculados em função do titulante adicionado, recorrendo a uma equação geral baseada no número médio de protonação de cada uma das bases. Ficou demonstrada a possibilidade de se determinar a soma de ácidos fortes completamente dissociados, soma de ácidos fracos com pK próximo a 4 (principalmente ácidos acético e fórmico), HCO3-/H2CO3 e a soma de bases fracas com pK ao redor de 9 (essencialmente NH3/NH4+). Durante as titulações, a facilidade em se coletar medidas de condutância simultaneamente às de pH levou a elaboração de um método sofisticado de análise de curvas de titulação condutométrica. Para tanto, desenvolveu-se uma equação de RNL baseada na contribuição das espécies em cada valor de pH e na condutância iônica medida (TC-RNL). A equação de TC-RNL é alimentada por dados de pH em função do titulante adicionado, oriundos de titulações potenciométricas. Dessa forma, foi possível caracterizar diretamente amônio e bicarbonato, além do conteúdo iônico total que não participa dos equilíbrios ácidos/base existentes no sistema. Adicionalmente, foi possível separar a contribuição do ácido acético da do fórmico, tarefa impossível por TP-RNL, ao menos nas baixas concentrações encontradas na chuva. Nas mesmas amostras de chuva tituladas foi procedida a análise por eletroforese capilar de zona com detecção condutométrica sem contato (CZE-CCD), conforme procedimento descrito na literatura, estimando-se os cátions e ânions majoritários. Num aperfeiçoamento do método para ânions, viabilizou-se a determinação simultânea HCO3-. Para validar os resultados obtidos por CZE-CCD, recorreu-se à cromatografia de íons. As concentrações de vários analitos, dependendo das amostras de chuva, avizinham-se do limite de quantificação das técnicas TP-RNL, TC-RNL e CZE-CCD. Mesmo assim, para as amostras de chuva analisadas, em geral, houve concordância satisfatória entre os valores estimados pelas três técnicas para espécies agrupadas da seguinte forma: ácidos fortes, ácidos fracos, amônio e bicarbonato. / Ivestigation of the variability of atmospheric chemical composition is an important tool for the evaluation and comprehension of anthropic emissions effects.Rainwater analysis has great importance in this context because wet deposition represents an efficient removal route of many atmospheric pollutants. The acidification of rainwater over wide regions of the planet is associated with the increased presence of strong acids, like sulfuric and nitric ones, and organic acids, such as acetic and formic, mainly originated from oxidative reactions od sulfur, nitrogen and carbon compounds in the atmosphere. In the context of a broad research line at IQ-USP devoted to the study of wet deposition and associated atmospheric chemistry, this dissertation advances the subject of using moderm chemometric methods to extract reliable analytical information from potentiometric and conductometric titrations of rainwater. The concentrations of acidic and alkaline species in rainwater are typically below 5 x 10-5 mol L-1, out of the reach of conventional potentiometric titrations (widely applied in the range of 10-1 and 10-3 mol L-1). Thus, multiparametric non-linear regression based on Levenberg-Marquardt method combined with coordinates transposition to reduce iterative calculation is proposed for the analysis of potentiometric data (PT-NLR). General equations based on the average protonation number of each base are used to describe the system. Bases concentrations and/or protonation constants are adjusted by NLR in order to minimize the sum-of-squares of the residuals between experimental and calculated values of the titration curves. The data analysis was tuned to provide four parameters as output: the sum of strong acids, the sum of weak acids with pK around 4.2 (mainly acetic and formic acids), the sum of HCO3-/H2co3 and the sum of weak bases with pK near 9 (essentially NH3/NH4+). To extract more analytical information from the acid/base titrations, conductance meassurements were made simultaneously with the pH readings, and a sophisticated data analysis method was envisioned. The pH data and available protonation constants for bases included in the model are used to compute the distribution of the species. The available conductivity of each species of the model is introduced in a general equation where the only unknowns are the total concentrations of the bases and of electrolyte not involved in acid/base equilibria. All these concentrations are adjusted by NLR on the conductance data, resulting in the first successful conductometric titration method with non-linear regression analysis, CT-NLR. The great advantage over PT-NLR was the capability to distinguish the contributions of acetic and formic acids in rainwater (an impossible task in PT-NLR method), but total strong acids, ammonium and bicarbonate are determined as well, beside the total ionic content of species not involved acid-base equilibria. Rainwater samples were also analysed by capillary zone electriphoresis equipment with contactless conductometric detection (CZE-CCD), as decribed in literature, regarding the major cations and anions. An improved CE method for anions was developed to afford the simultaneous determination of HCO3-. Validation of results was made with the reference method of ion chromatography. Although in many samples some analytes are low and close to the quantification limits od CZE-CCD, PT-NLR and CT-NLR, satisfactory agreement was achieved between values obtained by the three techniques for strong acids, weak acids, ammonium and bicarbonate.
|
7 |
Aperfeiçoamento de métodos para a determinação de componentes ácidos e básicos em amostras de água de chuva / Enhancement of methods for the determination of acid and alkaline compounds in rainwater samplesLucia Helena Gomes Coelho 14 April 2005 (has links)
O estudo da variação da composição atmosférica contribui para a compreensão dos efeitos das emissões antrópicas sobre a troposfera. A análise química da água de chuva assume importância neste contexto, uma vez que a precipitação úmida constitui um excelente meio de remoção de muitos poluentes da atmosfera. O aumento de acidez das chuvas, em várias partes do planeta, tem sido associado, predominantemente, à presença de ácidos fortes como o sulfúrico e nítrico, e ácidos orgânicos como acético e fórmico, originados pela oxidação de compostos de enxofre, nitrogênio e carbono, respectivamente. Dando continuidade a pesquisas anteriores sobre deposição úmida realizadas no IQ-USP, no presente trabalho buscou-se extrair mais informações de titulações potenciométricas e condutométricas de água de chuva, mediante aperfeiçoamento dos métodos de cálculo, com recursos quimiométricos modernos, de modo a complementar as medidas de pH e condutividade convencionais. As concentrações de espécies ácidas ou básicas nas amostras de água de chuva são da ordem de 10-5 mol L-1, muito abaixo das concentrações empregadas na prática cotidiana das titulações potenciométricas (tipicamente, no intervalo de 10-1 a 10-3 mol L-1). Dessa forma, propôs-se o uso de um método de regressão não linear (RNL) multiparamétrica, baseado no método de Levenberg-Marquardt, para a análise de dados potenciométricos (TP-RNL) após procedimento de transposição de coordenadas das curvas de titulação. Ao lado das determinações das concentrações dos analitos, pôde-se estimar ou refinar as constantes de protonação das bases de Brönsted presentes. Para tanto, procedeu-se ao ajuste por RNL das concentrações e/ou das constantes de protonação das bases presentes, de modo a minimizar o quadrado dos desvios entre os valores experimentais e os calculados em função do titulante adicionado, recorrendo a uma equação geral baseada no número médio de protonação de cada uma das bases. Ficou demonstrada a possibilidade de se determinar a soma de ácidos fortes completamente dissociados, soma de ácidos fracos com pK próximo a 4 (principalmente ácidos acético e fórmico), HCO3-/H2CO3 e a soma de bases fracas com pK ao redor de 9 (essencialmente NH3/NH4+). Durante as titulações, a facilidade em se coletar medidas de condutância simultaneamente às de pH levou a elaboração de um método sofisticado de análise de curvas de titulação condutométrica. Para tanto, desenvolveu-se uma equação de RNL baseada na contribuição das espécies em cada valor de pH e na condutância iônica medida (TC-RNL). A equação de TC-RNL é alimentada por dados de pH em função do titulante adicionado, oriundos de titulações potenciométricas. Dessa forma, foi possível caracterizar diretamente amônio e bicarbonato, além do conteúdo iônico total que não participa dos equilíbrios ácidos/base existentes no sistema. Adicionalmente, foi possível separar a contribuição do ácido acético da do fórmico, tarefa impossível por TP-RNL, ao menos nas baixas concentrações encontradas na chuva. Nas mesmas amostras de chuva tituladas foi procedida a análise por eletroforese capilar de zona com detecção condutométrica sem contato (CZE-CCD), conforme procedimento descrito na literatura, estimando-se os cátions e ânions majoritários. Num aperfeiçoamento do método para ânions, viabilizou-se a determinação simultânea HCO3-. Para validar os resultados obtidos por CZE-CCD, recorreu-se à cromatografia de íons. As concentrações de vários analitos, dependendo das amostras de chuva, avizinham-se do limite de quantificação das técnicas TP-RNL, TC-RNL e CZE-CCD. Mesmo assim, para as amostras de chuva analisadas, em geral, houve concordância satisfatória entre os valores estimados pelas três técnicas para espécies agrupadas da seguinte forma: ácidos fortes, ácidos fracos, amônio e bicarbonato. / Ivestigation of the variability of atmospheric chemical composition is an important tool for the evaluation and comprehension of anthropic emissions effects.Rainwater analysis has great importance in this context because wet deposition represents an efficient removal route of many atmospheric pollutants. The acidification of rainwater over wide regions of the planet is associated with the increased presence of strong acids, like sulfuric and nitric ones, and organic acids, such as acetic and formic, mainly originated from oxidative reactions od sulfur, nitrogen and carbon compounds in the atmosphere. In the context of a broad research line at IQ-USP devoted to the study of wet deposition and associated atmospheric chemistry, this dissertation advances the subject of using moderm chemometric methods to extract reliable analytical information from potentiometric and conductometric titrations of rainwater. The concentrations of acidic and alkaline species in rainwater are typically below 5 x 10-5 mol L-1, out of the reach of conventional potentiometric titrations (widely applied in the range of 10-1 and 10-3 mol L-1). Thus, multiparametric non-linear regression based on Levenberg-Marquardt method combined with coordinates transposition to reduce iterative calculation is proposed for the analysis of potentiometric data (PT-NLR). General equations based on the average protonation number of each base are used to describe the system. Bases concentrations and/or protonation constants are adjusted by NLR in order to minimize the sum-of-squares of the residuals between experimental and calculated values of the titration curves. The data analysis was tuned to provide four parameters as output: the sum of strong acids, the sum of weak acids with pK around 4.2 (mainly acetic and formic acids), the sum of HCO3-/H2co3 and the sum of weak bases with pK near 9 (essentially NH3/NH4+). To extract more analytical information from the acid/base titrations, conductance meassurements were made simultaneously with the pH readings, and a sophisticated data analysis method was envisioned. The pH data and available protonation constants for bases included in the model are used to compute the distribution of the species. The available conductivity of each species of the model is introduced in a general equation where the only unknowns are the total concentrations of the bases and of electrolyte not involved in acid/base equilibria. All these concentrations are adjusted by NLR on the conductance data, resulting in the first successful conductometric titration method with non-linear regression analysis, CT-NLR. The great advantage over PT-NLR was the capability to distinguish the contributions of acetic and formic acids in rainwater (an impossible task in PT-NLR method), but total strong acids, ammonium and bicarbonate are determined as well, beside the total ionic content of species not involved acid-base equilibria. Rainwater samples were also analysed by capillary zone electriphoresis equipment with contactless conductometric detection (CZE-CCD), as decribed in literature, regarding the major cations and anions. An improved CE method for anions was developed to afford the simultaneous determination of HCO3-. Validation of results was made with the reference method of ion chromatography. Although in many samples some analytes are low and close to the quantification limits od CZE-CCD, PT-NLR and CT-NLR, satisfactory agreement was achieved between values obtained by the three techniques for strong acids, weak acids, ammonium and bicarbonate.
|
8 |
Determinação de dioxido de carbono por titulação potenciométrica (Gran) após absorção em hidróxido de sódio / Determination of carbon dioxide by potenciometric titration (GRAN) after absorption in sodium hydroxideCardoso, Luiza Maria Nunes 21 March 1989 (has links)
O presente trabalho consistiu no desenvolvimento de metodologia simples e de baixo custo para determinação de gás carbônico da atmosféra. O CO2 é absorvido em solução aquosa de NaOH, 10-4M e, a solução resultante é adicionado NaCl para concentração final de 1,0M. A seguir, titula-se com ácido clorídrico 10-3M, potenciometricamente. A fim de se evitar interferência de íons carbonato possivelmente existentes na solução original de NaOH. Uma alíquota desta é titulada préviamente antes da absorção de CO2, constituindo o \"branco\". A solução de hidróxido de sódio e carbonato é titulada a seguir e, considera-se a diferença do volume no ponto final da solução do branco e da amostra; a avaliação é efetuada segundo Gran II, estudado por Pressinotti (9). Foram efetuados estudos experimentais de introdução do gás carbônico em solução de hidróxido de sódio. Estudaram-se os métodos com o uso de: a - com o uso de bomba misturadora; b - com o uso de frascos lavadores; c - com o uso de injeção com seringa em frasco plástico. Esta última mostrou ser simples e rápida para o processo. / This work deals with the development of a simple and low cost methodology the determination of carbonic gas in the atmosphere. The CO2 is absorved in aqueous solution of NaOH 10-4; M and, to t he resulting solution, NaCl is added to a concentratian of 1.0M and the potentiometric titration is done with HCl 10-3; M solution. To avoid the interference of carbonate ions in the original NaOH solution, an aliquot of the NaOH solution is previously titrated just before the absorption af CO2; this previous titration is the \"blank\". The final solulion of NaOH and carbonate ions is titrated and one measures the diference of the volume at the end point of the \"blank\" and the sample itself. The is made by Gran II method according to Pressinotti (9). Studies about introdution of CO2 in the solution of NaOH were made.The following methods were studied: a - by mixer bomb; b - by the cylindrical vessel bubble absorber; c - by the use of syringe injection. This last one showed to be extremaly simple and of low cost.
|
9 |
O processo de titulação das comunidades quilombolas à luz do direito fundamental à memória: os casos de “Retiro” e “Linharinho”Machado, Thiago Luiz D'agostin 04 February 2012 (has links)
Submitted by Ana Paula Florentino Santos Pires (anapaulapires@fdv.br) on 2018-08-24T00:26:28Z
No. of bitstreams: 1
Thiago D'Agostin.pdf: 2839845 bytes, checksum: 315b67d71d7b482d558238fcc63e0fd5 (MD5) / Rejected by Ana Paula Galdino (repositorio@fdv.br), reason: Corrigir na descrição do título e também na referência - inserir "retiro" e "linharinho" com iniciais maiúsculas. on 2018-08-24T14:07:55Z (GMT) / Submitted by Ana Paula Florentino Santos Pires (anapaulapires@fdv.br) on 2018-08-24T16:54:32Z
No. of bitstreams: 1
Thiago D'Agostin.pdf: 2839845 bytes, checksum: 315b67d71d7b482d558238fcc63e0fd5 (MD5) / Approved for entry into archive by Ana Paula Galdino (repositorio@fdv.br) on 2018-08-24T20:02:24Z (GMT) No. of bitstreams: 1
Thiago D'Agostin.pdf: 2839845 bytes, checksum: 315b67d71d7b482d558238fcc63e0fd5 (MD5) / Made available in DSpace on 2018-08-24T20:02:24Z (GMT). No. of bitstreams: 1
Thiago D'Agostin.pdf: 2839845 bytes, checksum: 315b67d71d7b482d558238fcc63e0fd5 (MD5)
Previous issue date: 2012-02-04 / Busca compreender os entraves jurídicos à efetivação do art. 68 do Ato das Disposições Constitucionais Transitórias, que se dá por meio do procedimento de titulação, atualmente previsto no Decreto nº 4.887/2003. A metodologia empregada foi a dialética e as técnicas adotadas foram a pesquisa bibliográfica e a análise documental de dois procedimentos de titulação. Os procedimentos referem-se a duas comunidades quilombolas situadas no Espírito Santo: Retiro e Linharinho. Anterior à investigação, realiza-se uma análise do direito fundamental à memória, implícito constitucionalmente, por meio das relações entre a memória, o tempo e o direito. A memória é utilizada como fio condutor para demonstrar os cem anos de esquecimento do Estado com relação às comunidades quilombolas, uma vez que não houve nenhum tratamento jurídico desta questão desde que estas deixaram de ser perseguidas, com a abolição, até a Constituição de 1988. Esta reconheceu as comunidades, principalmente por meio do artigo mencionado e ocasionou intenso debate, ao conferir expressamente aos "remanescentes das comunidades dos quilombos" o direito à terra. O silenciamento jurídico de tanto tempo permaneceu após a Constituição, uma vez que não foram produzidas leis que efetivassem o dispositivo em comento, mas apenas decretos. Ainda estes, surgiram efetivamente apenas dez anos após a Constituição, o que evidencia uma característica que acompanha tais comunidades: a invisibilidade, enquanto característica essencial do lado de lá da linha abissal. Realiza-se, então, uma análise breve da trajetória jurídica e das causas da invisibilidade das comunidades quilombolas. Restando assentadas as bases jurídicas e os aspectos sociais relevantes ao tema, produziu-se uma extensa investigação acerca dos óbices existentes nos dois procedimentos de titulação citados. Após o relato sucinto de ambos, passou-se às análises comparativa e conclusiva, nas quais se revelaram como principais entraves jurídicos a ausência de lei que regule especificamente o tema e a atuação arbitrária do Judiciário. / This work seeks to comprehend the lawful obstacles on the way to implementing article 68 of theTemporary Constitutional Provisions Act, which can be brought about by land title processes, currently provided in Decree 4.887/2003. It used a dialetic methodology and employed as techniques literature review and document analysis of two land title cases. These cases are in regard to two traditional black communities located in the state of Espírito Santo: Retiro and Linharinho. Prior to investigation, it analyzes the fundamental right to memory implicit in the Constitution, by establishing the relation among memory, time and law. Memory is used as the linking element to demonstrate how Brazil has forgotten its traditional black communities for one hundred years. From abolition of slavery – when these communites stopped being persecuted – to the Constitution of 1988 there was no legal treatment whatsoever. The Constitution recognized these communites, primarily in the proviso quoted and ensued intese debates by clearly acknowledging the right to land of the “remaining members of the ancient runaway slave communities”. The enduring lawful silence remained after the Constitution was promulgated, since no legislation was approved to make the article effective, but only administrative decrees. Yet these latter have only appeared ten years after the Constitution, which attests a feature of these communities that has accompanied them throughout their existence: invisibility. This is an essential attribute keeping them on the other side of the abyssal line. Then, from this perspective, the work briefly analyzed the legal timeline and the causes of invisibility of the traditional black communities. Next, it summarized the two cases cited and conducted a thorough investigation on them, revealing as the main lawful obstacles to realizing the constitutional proviso: the inexistence of especific law regarding the issue and the arbitrary acting of the Judiciary.
|
10 |
Atributos da validação do método analítico para quantificação da biotina empregando a técnica potenciométricaGonçalves, Gabriela Soldi [UNESP] 20 December 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:18Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-12-20Bitstream added on 2014-06-13T20:28:32Z : No. of bitstreams: 1
goncalves_gs_me_arafcf.pdf: 376750 bytes, checksum: d261fb301fa1b4c966236fbf2eb5c9d0 (MD5) / Universidade Estadual Paulista (UNESP) / O presente trabalho consiste no desenvolvimento de um método analítico para determinação de biotina, utilizando-se a potenciometria indireta. O objetivo é apresentar a validação de método analítico como um processo que estime a eficiência do método proposto na rotina do laboratório para garantia da qualidade total. É um método que envolve equipamento simples e pouco dispendioso como o potenciômetro, que possibilita medir com precisão o valor da concentração de biotina. O doseamento quantitativo de biotina baseia-se no estudo das reações oscilantes do analito perante as análises da titulação indireta utilizando potenciômetro automático. A concentração de biotina foi determinada com massa adicionada conhecida numa matriz que simula uma cápsula, contendo aerosil (1%), estearato de magnésio (1%), celulose microcristalina (20%), amido (40%) e lactose q.s.p. Os resultados mostraram um valor médio de biotina (massa adicionada de aproximadamente 25 mg) determinada de 99,4% com desvio-padrão de 0,0345. As condições experimentais como temperatura, vidraria e concentração dos reagentes foram otimizadas. Os parâmetros investigados no processo de validação para demonstrar o desempenho do método foram: especificidade, linearidade, intervalo, precisão tanto repetitividade, quanto intermediária, exatidão e robustez. O tratamento estatístico dos dados da validação do método analítico envolveu a determinação da média, do desvio padrão e do coeficiente de variação. Para obtenção da curva de calibração se fez necessária a determinação da equação da reta, regressão linear e coeficiente de correlação linear. Este método apresenta grande aplicabilidade em soluções turvas, fluorescentes, opacas ou coradas, ou quando não existem, ou não podem aplicar-se indicadores visuais apropriados. Há possibilidade de determinação... / The present work shows the development of an analytical method for the determination of biotin by using indirect potentiometry. The main goal is to present the validation of analytical methods as a process to estimate the efficiency of the proposed methodology in the laboratory routine for the guaranty of total quality. This method involves simple and low cost devices as the potentiometer, which allows the precise measurement of biotin concentration. The quantitative dosing of biotin is based on the study of the oscillating chemical reactions with the analyte by performing the analysis of the indirect titration with an automatic potentiometer. Biotin concentration was determined by adding a known mass to a matrix that simulates a capsule containing aerosol (1%), estearato de magnésio (1%), celulose microcristalina (20%), amido (40%) e lactose q.s.p. The results showed an average value for the determination of biotin (added mass was ca. 25 mg) of 99.4% with a standard deviation of 0.0345. The experimental conditions as temperature, glassware, and concentration of the chemicals were optimized. The investigated parameters of the validation procedure to demonstrate the performance of the method were: specificity, linearity, interval, precision (repeatability and intermediate), exactness and robustness. The statistical treatment of the data for the validation of the analytical method involved the determination of the average value, standard deviation, and the variation coefficient. In order to obtain the calibration curve, the line´s equation, the linear regression and the coefficient of linear correlation were determined. This method shows great applicability for turbid, fluorescent, opaque or color solutions, or if an appropriate visual indicator is not available or cannot be applied. The method also shows the possibility for the determination of a sequence of equivalence... (Complete abstract click electronic access below)
|
Page generated in 0.061 seconds