• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • 1
  • Tagged with
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Overview of the 2015 Algodones Sand Dunes field campaign to support sensor intercalibration

McCorkel, Joel, Bachmann, Charles M., Coburn, Craig, Gerace, Aaron, Leigh, Larry, Czapla-Myers, Jeff, Helder, Dennis, Cook, Bruce 18 September 2017 (has links)
Several sites from around the world are being used operationally and are suitable for vicarious calibration of space-borne imaging platforms. However, due to the proximity of these sites (e.g., Libya 4), a rigorous characterization of the landscape is not feasible, limiting their utility for sensor intercalibration efforts. Due to its accessibility and similarities to Libya 4, the Algodones Sand Dunes System in California, USA, was identified as a potentially attractive intercalibration site for space-borne, reflective instruments such as Landsat. In March 2015, a 4-day field campaign was conducted to develop an initial characterization of Algodones with a primary goal of assessing its intercalibration potential. Five organizations from the US and Canada collaborated to collect both active and passive airborne image data, spatial and temporal measurements of spectral bidirectional reflectance distribution function, and in-situ sand samples from several locations across the Algodones system. The collection activities conducted to support the campaign goal is summarized, including a summary of all instrumentation used, the data collected, and the experiments performed in an effort to characterize the Algodones site. (C) The Authors.
2

Spectroscopie ultraviolet-visible et infrarouge de molécules clés atmosphériques / Ultraviolet-visible and infared spectroscopy of atmospheric key molecules

Gratien, Aline 06 November 2008 (has links)
Les mesures des constituants mineurs de l’atmosphère sont souvent réalisées à partir du sol, d’avions, de ballons ou encore par les satellites. Celles-ci sont effectuées régulièrement par des spectromètres fonctionnant dans des régions spectrales différentes, en particulier dans les domaines UV-visible et infrarouge. Or, l’analyse et l’interprétation des spectres atmosphériques requièrent une bonne connaissance des paramètres spectroscopiques. Cependant, les mesures de ces paramètres sont généralement effectuées dans un domaine spectral donné (IR ou UV) et peu d’études de laboratoire ont vérifié la cohérence entre les sections efficaces UV et IR. Il est alors difficile de comparer des profils atmosphériques déduits de mesures effectuées dans différents domaines. Le but de cette étude est donc d’intercalibrer les spectres UV et IR de composés atmosphériques en déterminant et/ou e vérifiant la cohérence des sections efficaces publiées dans la littérature. Ces expériences ont été effectuées dans la chambre de simulation du LISA, en acquérant simultanément des spectres UV et IR à température ambiante et à pression atmosphérique au sein d’une cellule optique commune. Ce travail a porté sur trois molécules clés atmosphériques : le formaldéhyde (et ses isotopes), l’ozone et l’acide nitreux. Ces composés jouent un rôle fondamental dans la physico-chimie atmosphérique puisqu’ils constituent les sources du principal oxydant de l’atmosphère : le radical hydroxyle. Ce travail de laboratoire a permis ainsi d’obtenir des spectres précis et cohérents de l’ozone, du formaldéhyde et de l’acide nitreux dans le moyen infrarouge et l’UV-visible afin d’améliorer la précision de leurs mesures. / Optical measurements of atmospheric minor constituents are carried using spectrometers working in different spectral ranges by ground, air or satellite instruments. However, the analysis and interpretation of the corresponding atmospheric spectra require good knowledge of the spectroscopic parameters. Moreover, spectroscopic measurements in laboratory are generally performed in a spectral region (IR or UV) and little of laboratory study has ever verified the consistency between the cross-sections in UV and IR. It is then difficult to compare atmospheric profiles measured in different regions. Consequently, the aim of the study was to intercalibrate spectra in the infrared and ultraviolet regions, by determining and/or checking the coherence of the cross section published in the literature. The experiments were performed at LISA by acquiring simultaneously UV and IR spectra at room temperature and atmospheric pressure using a common optical cell. This work relates to three atmospheric key species : formaldehyde (and its isotopes), ozone and nitrous acid. These compounds play a fundamental role in atmospheric physico-chemistry since they constitute the sources of the principal oxidant of the atmosphere: the hydroxyl radical. This laboratory work enables to have precise and coherent spectra of ozone, formaldehyde and nitrous acid in the mid-infrared and UV-visible regions in order to improve the precision of their measurements.
3

Spectroscopie ultraviolet-visible et infrarouge de molécules clés atmosphériques

Gratien, Aline 06 November 2008 (has links) (PDF)
Les mesures des constituants mineurs de l'atmosphère sont souvent réalisées à partir du sol, d'avions, de ballons ou encore par les satellites. Celles-ci sont effectuées régulièrement par des spectromètres fonctionnant dans des régions spectrales différentes, en particulier dans les domaines UV-visible et infrarouge. Or, l'analyse et l'interprétation des spectres atmosphériques requièrent une bonne connaissance des paramètres spectroscopiques. Cependant, les mesures de ces paramètres sont généralement effectuées dans un domaine spectral donné (IR ou UV) et peu d'études de laboratoire ont vérifié la cohérence entre les sections efficaces UV et IR. Il est alors difficile de comparer des profils atmosphériques déduits de mesures effectuées dans différents domaines. Le but de cette étude est donc d'intercalibrer les spectres UV et IR de composés atmosphériques en déterminant et/ou e vérifiant la cohérence des sections efficaces publiées dans la littérature. Ces expériences ont été effectuées dans la chambre de simulation du LISA, en acquérant simultanément des spectres UV et IR à température ambiante et à pression atmosphérique au sein d'une cellule optique commune. Ce travail a porté sur trois molécules clés atmosphériques : le formaldéhyde (et ses isotopes), l'ozone et l'acide nitreux. Ces composés jouent un rôle fondamental dans la physico-chimie atmosphérique puisqu'ils constituent les sources du principal oxydant de l'atmosphère : le radical hydroxyle. Ce travail de laboratoire a permis ainsi d'obtenir des spectres précis et cohérents de l'ozone, du formaldéhyde et de l'acide nitreux dans le moyen infrarouge et l'UV-visible afin d'améliorer la précision de leurs mesures.
4

Towards the Use of Satellite Data in Security Policy-Related Prediction

Jayaweera, Mary Chrishani January 2021 (has links)
Inadequate economic data makes it more difficult for its incorporation in security-policy related prediction and there is a need for alternative datasets. Satellite data, more specifically nighttime lights data, can be used as a proxy for the economy. In this project, the correlation between nighttime lights and the economy between 1992 and 2018 is explored for five countries in Africa: Nigeria, Libya, the Central African Republic, the Republic of the Congo and Ghana. Data from two different satellite series, DMSP-OLS and VIIRS-DNB are used, and the extracted datasets are calibrated for the differences or intercalibrated. There was found to be a high correlation for two of the countries, the Republic of the Congo and Ghana. The biggest improvement can be made by developing the intercalibration method. A pitfall of the method is that it is not generally applicable as unique circumstances seen for Nigeria show in the correlation results.
5

Mesures de precision au LEP et au SppS et instrumentation aupres du LHC

Djama, Fares 29 April 2011 (has links) (PDF)
.

Page generated in 0.0786 seconds