• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 8
  • 3
  • 2
  • 1
  • Tagged with
  • 84
  • 54
  • 36
  • 31
  • 30
  • 26
  • 25
  • 23
  • 20
  • 19
  • 18
  • 17
  • 16
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Multiclassificador inteligente de falhas no domínio do tempo em motores de indução trifásicos alimentados por inversores de frequência / Time domain intelligent faults multiclassifier in inverter fed three-phase induction motors

Godoy, Wagner Fontes 18 April 2016 (has links)
Os motores de indução desempenham um importante papel na indústria, fato este que destaca a importância do correto diagnóstico e classificação de falhas ainda em fase inicial de sua evolução, possibilitando aumento na produtividade e, principalmente, eliminando graves danos aos processos e às máquinas. Assim, a proposta desta tese consiste em apresentar um multiclassificador inteligente para o diagnóstico de motor sem defeitos, falhas de curto-circuito nos enrolamentos do estator, falhas de rotor e falhas de rolamentos em motores de indução trifásicos acionados por diferentes modelos de inversores de frequência por meio da análise das amplitudes dos sinais de corrente de estator no domínio do tempo. Para avaliar a precisão de classificação frente aos diversos níveis de severidade das falhas, foram comparados os desempenhos de quatro técnicas distintas de aprendizado de máquina; a saber: (i) Rede Fuzzy Artmap, (ii) Rede Perceptron Multicamadas, (iii) Máquina de Vetores de Suporte e (iv) k-Vizinhos-Próximos. Resultados experimentais obtidos a partir de 13.574 ensaios experimentais são apresentados para validar o estudo considerando uma ampla faixa de frequências de operação, bem como regimes de conjugado de carga em 5 motores diferentes. / Induction motors play an important role in the industry, a fact that highlights the importance of correct diagnosis and classification of faults on these machines still in early stages of their evolution, allowing increase in productivity and mainly, eliminating major damage to the processes and machines. Thus, the purpose of this thesis is to present an intelligent multi-classifier for the diagnoses of healthy motor, short-circuit faults in the stator windings, rotor broken bars and bearing faults in induction motors operating with different models of frequency inverters by analyzing the amplitude of the stator current signal in the time domain. To assess the classification accuracy across the various levels of faults severity, the performances of four different learning machine techniques were compared; namely: (i) Fuzzy ARTMAP network, (ii) Multilayer Perceptron Network, (iii) Support Vector Machine and (iv) k-Nearest-Neighbor. Experimental results obtained from 13.574 experimental tests are presented to validate the study considering a wide range of operating frequencies and also load conditions using 5 different motors.
62

Avaliação operacional das diferentes arquiteturas de interligação de geradores fotovoltaicos à rede elétrica

TELES, Mailson Borges 13 June 2017 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-16T18:20:59Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoOperacionalDiferentes.pdf: 22302291 bytes, checksum: 8120408e0a53d61465fff8f63977437e (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-11-14T16:46:30Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoOperacionalDiferentes.pdf: 22302291 bytes, checksum: 8120408e0a53d61465fff8f63977437e (MD5) / Made available in DSpace on 2017-11-14T16:46:30Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoOperacionalDiferentes.pdf: 22302291 bytes, checksum: 8120408e0a53d61465fff8f63977437e (MD5) Previous issue date: 2017-06-13 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho avalia experimentalmente as tecnologias string, microinversor e conversor c.c.-c.c., de modo a contribuir para a construção do conhecimento científico da aplicação das diferentes arquiteturas de interligação de geradores fotovoltaicos à rede elétrica convencional. Para isso são utilizados diferentes sistemas instalados no laboratório do GEDAE/UFPA, Região Norte do país. Comparou-se os desempenhos de acordo com as informações nos diferentes mecanismos de aquisição de dados disponíveis no laboratório. Tendo em vista que alguns desses mecanismos de aquisição de dados fornecem somente o valor da energia acumulada ao longo do dia, foi dado um enfoque na operação global dos diferentes sistemas analisados. Contudo, naqueles sistemas onde maiores detalhes da operação foram monitorados, seja por sistemas de aquisição do próprio equipamento ou por equipamentos existentes no laboratório (osciloscópio digital Fluke, wattímetro, etc), análises pontuais importantes, mais detalhadas da operação do sistema, foram desenvolvidas. Os resultados obtidos mostram que o conversor c.c.-c.c. apresentou desempenhos superiores aos demais sistemas monitorados. Contudo constatou-se a ocorrência de problemas devido ao processo de pareamento dos conversores c.c.-c.c. na operação do sistema que permanecem até os dias de hoje. / This work aims to experimentally evaluate the string, microinverter and d.c.-d.c. converter technologies, in order to contribute to scientific knowledge construction in applications of the different interconnection architectures of photovoltaic generators to the conventional electric grid. For this, were used different systems installed at GEDAE’s laboratory (UFPA), located in northern region of the country. It was compared the performances according to the information from different data acquisition mechanisms available in the laboratory. In face of some of these data acquisition mechanisms provide only the value of energy accumulated throughout the day, a focus was given on the overall operation of the different systems analyzed. However, in those systems which greater operational details were monitored, either by the equipment's own acquisition system or already existing equipment in the laboratory (Fluke Digital Storage Oscilloscope, Digital Power Meter, etc.), important point analyzes with more detailed operation of the system were performed. The obtained results show that the d.c.-d.c. converters system presented superior performance to the other monitored systems. However, it has been found the occurrence of problems due to the pairing process of the d.c.-d.c. power converters in the operation of such systems that remain until now.
63

Impacto de geradores conectados via inversores na coordenação da proteção em redes de distribuição de energia elétrica

CORDEIRO, Murillo Augusto de Melo 11 August 2017 (has links)
Submitted by Carmen Torres (carmensct@globo.com) on 2018-02-09T18:27:05Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoGeradoresConectados.pdf: 3677555 bytes, checksum: cacdc89995e90a3cb08a7b651b188a31 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-02-21T16:54:16Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoGeradoresConectados.pdf: 3677555 bytes, checksum: cacdc89995e90a3cb08a7b651b188a31 (MD5) / Made available in DSpace on 2018-02-21T16:54:16Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoGeradoresConectados.pdf: 3677555 bytes, checksum: cacdc89995e90a3cb08a7b651b188a31 (MD5) Previous issue date: 2017-08-11 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Apesar de suas vantagens indiscutíveis, a geração distribuída (GD) pode afetar negativamente alguns aspectos da operação dos sistemas de energia elétrica, especialmente um ponto pouco explorado: a proteção das redes de distribuição de energia elétrica e sua interação com os sistemas de geração de energia baseados em inversores. Nesta dissertação, o impacto da GD conectada via inversor na coordenação religador-fusível de esquemas de proteção em redes de distribuição é minuciosamente estudado. Simulações são realizadas por meio do software DIgSILENT PowerFactory através de curtos-circuitos monofásicos e trifásicos considerando diferentes localizações de faltas e da GD, níveis de penetração e de operação, e outros aspectos que influem na descoordenação da proteção em um sistema de distribuição teste real do IEEE de 34 barras. A contribuição à corrente de curto-circuito de geradores baseados em inversores é também investigada por meio de simulações no modelo de transitórios eletromagnéticos do software. Os resultados mostraram que a elevada penetração da GD conectada via inversores aumenta a corrente de curto-circuito que passa pelo fusível e o faz operar mais rapidamente do que o religador em uma condição de falta, levando à perda de coordenação religador-fusível. É feita uma discussão geral dos resultados, identificando os eventuais cuidados adicionais que devem ser considerados a fim de manter a coordenação e seletividade entre as proteções de um sistema de distribuição. / Despite its many benefits, the Distributed Generation (DG) can adversely affect some aspects related to the operation performance of electrical power systems, especially a no so deeply explored point: the interaction between the protection systems and inverter-based power generation units. In this dissertation, the impact of inverter-based DGs units on the fuse-recloser coordination schemes used in distribution networks is thoroughly studied. The simulations were conducted using the software package DIgSILENT Power Factory through several single-phase and three-phase short circuits along the distribution network, considering different fault locations, penetration levels of DGs, operating conditions, and other aspects that impact over the protection miscoordination in an IEEE real test distribution system of 34 busbars. The contribution to the short-circuit current of inverter-based generators is also investigated through simulations on electromagnetic transients models available in the software. The simulation results shows that significant inverter-based DG penetration levels on distribution feeders increase the short-circuit current that passes through the fuse and make it operate faster than the recloser in a fault condition, leading to loss of fuse-recloser coordination in a time frame base. A general discussion of the results is performed, identifying some recommended corrective actions that should be considered in order to maintain the coordination and selectivity between the distribution system protection devices located throughout the network.
64

Avaliação do desempenho das funções de controle volt-watt e volt-var em inversores fotovoltaicos integrados nas redes de distribuição / Evaluation of the performance of the volt-watt and volt-var control functions in photovoltaic inverters integrated in the distribution networks

WANZELER, Tiago Machado 27 March 2018 (has links)
Submitted by Luciclea Silva (luci@ufpa.br) on 2018-07-19T17:42:08Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ avaliacaodesempenhofuncoes.pdf: 5239412 bytes, checksum: a7be25c49d350063c87bb85986bb7199 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-07-19T17:42:46Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ avaliacaodesempenhofuncoes.pdf: 5239412 bytes, checksum: a7be25c49d350063c87bb85986bb7199 (MD5) / Made available in DSpace on 2018-07-19T17:42:46Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ avaliacaodesempenhofuncoes.pdf: 5239412 bytes, checksum: a7be25c49d350063c87bb85986bb7199 (MD5) Previous issue date: 2018-03-27 / Esta dissertação aborda alguns dos principais problemas operacionais enfrentados pelos operadores de redes de distribuição devido à elevada integração de geradores fotovoltaicos (FV), tais como sobretensões e comutações excessivas de tape nos autotransformadores reguladores de tensão. Essas situações estão sendo continuamente estudadas, tendo em vista que podem causar problemas de qualidade de tensão e reparos em reguladores de tensão. O problema da sobretensão pode ser causado por uma injeção significativa de potência ativa da geração FV à rede. Paralelamente, as variações rápidas e significativas na potência ativa injetada pelo gerador FV, associadas com os transitórios de nuvens, podem resultar no aumento excessivo de comutações de tape no regulador de tensão, que podem acabar diminuindo a vida útil e aumentar a quantidade de manutenções realizadas nestes equipamentos. Neste contexto, surgiram as funções de controle Volt-Watt e Volt-Var prensentes nos inversores FV inteligentes, que foram adicionadas em estudos recentes para mitigar as sobretensões. Este trabalho mostra como as funções de controle Volt-Watt e Volt-Var mitigam os problemas de sobretensão e regulação de tensão em redes de distribuição com presença de geradores FV. Simulações de fluxo de potência de séries temporais em alimentadores simples de BT e MT com presença da geração FV foram realizadas em cenários de alta e baixa variabilidade solar. / This dissertation addresses some of the major operational problems faced by distribution system operators due to the high integration of photovoltaic (PV) generators, such as overvoltages and excessive tap counts in step voltage regulators (SVR). These situations are continually being studied, since they can cause voltage quality problems and damage in SVRs. The overvoltage problem can be caused by a significant injection of active power from the PV generation to the network. Moreover, the rapid and significant variations in PV generator active power associated with cloud transients result in an increase of voltage regulator tap counts, which can affect the useful life of device. In this context, the smart inverters Volt-Watt and Volt-Var control functions have been added in recent studies to mitigate the overvoltages. This work shows how Volt-Watt and Volt-Var control functions mitigate the overvoltage and voltage regulation problems in distribution networks with PV generation. Time series power flow simulations on LV and MV single feeders with PV solar plant have been performed in high and low solar variability scenarios.
65

Conversor ressonante para geração de ozônio aplicado à água de processos de higienização industrial, com controle digital /

Alburqueque Valdivia, Marlon Jesus January 2019 (has links)
Orientador: Carlos Alberto Canesin / Resumo: No presente trabalho de dissertação, é analisado e desenvolvido um conversor ressonante com o objetivo de produzir ozônio, aplicado à água de processos de higienização industrial. Na atualidade, no ano de 2018, dois dos fatores de grande importância no desenvolvimento de conversores para geração de ozônio são: a eficiência energética, isto é, quanta energia é aproveitada em relação à energia total fornecida ao conversor, e a outra é a produção de ozônio fazendo uso dessa energia aproveitada. Os dois fatores não necessariamente estão relacionados, por exemplo, para dois conversores distintos com a mesma energia disponível, pode acontecer que em um deles possa ser produzido maiores concentrações de ozônio com um menor aproveitamento de energia. Portanto, este trabalho enfatiza a melhoria da eficiência energética na produção de ozônio, empregando comutação suave nas estruturas envolvidas do conversor ressonante proposto, o que resulta em uma eficiência energética de 91,57%. A estrutura do conversor proposto apresenta dois estágios em cascata, o primeiro deles, um conversor que é responsável por gerar um barramento CC estável de 400,5 V e que atende aos requisitos de fator de potência e distorção harmônica total com valores de 0,994 e 5,79%(para a corrente de entrada), respectivamente, e o segundo, um inversor ressonante capaz de fornecer uma tensão de 4,4 kV com uma frequência de 10 kHz que atua como fonte de alimentação de um reator conformado por câmaras de descarga usadas em ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the present dissertation, it is studied and developed a resonant converter in order to produce ozone, applied in water treatment for cleaning processes. Currently, in the year 2018, two of the factors of great importance in the development of converters for ozone generation are: energy efficiency, that is, how much energy is used in relation to the total energy supplied to the converter, and the other is the production of ozone making use of this energy harnessed. The two factors are not necessarily related, for example, for two different converters with the same energy available, it can happen that in one of them can be produced higher concentrations of ozone with a lower use of energy. Therefore, this work emphasizes the improvement of energy efficiency in the production of ozone using soft switching in the involved structures of the proposed resonant converter, which results in an energy efficiency of 91.57%. The structure of the proposed converter has two stages in cascade, the first one, a converter that is responsible for generating a stable DC bus of 400.5 V and that meets the requirements of power factor and total harmonic distortion with values of 0.994 and 5.79% (for the input current), respectively, and the second, a resonant inverter capable of providing a voltage of 4.4 kV with a frequency of 10 kHz which acts as a power supply for a reactor formed by discharge chambers used in ozone generation applications by electric discharge. Naturally, relevant ozone info... (Complete abstract click electronic access below) / Mestre
66

Projeto inversol - desenvolvimento de uma fonte ininterrupta de energia com possibilidade de uso em sistema fotovoltaico / INVERSOL â DEVELOPMENT OF UNINTERRUPTIBLE POWER SUPLLY TO BE USED IN A PHOTOVOLTAIC SYSTEM

Lucas Maciel Menezes 10 April 2007 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / O estudo para o desenvolvimento de uma fonte ininterrupta de energia com possibilidade de uso em sistema fotovoltaico, tem como motivaÃÃo que a larga escala da produÃÃo desse tipo de equipamento possa reduzir o custo dos conversores de eletrÃnica de potÃncia associados a uma instalaÃÃo fotovoltaica. O projeto proporem a uniÃo de topologias de conversores, resultando em uma UPS do tipo on-line com tensÃo de entrada e de saÃda de 220 Volts 60 Hz, potÃncia total de 715VA, rendimento de 88%, isolada em alta freqÃÃncia e com correÃÃo do fator de potÃncia na entrada. Sendo composta por um retificador na entrada com topologia de um conversor em ponte completa alimentado em corrente, esse conversor à responsÃvel por prover a correÃÃo do fator de potÃncia na entrada e da isolaÃÃo galvÃnica em alta freqÃÃncia. Um inversor em ponte completa com filtro LC e modulaÃÃo PWM unipolar, que à capaz de entregar uma tensÃo senoidal para a carga e um conversor boost de alto ganho que cumpre o papel de elevar a tensÃo de 24 Volts do banco de baterias para a tensÃo de 400 Volts do barramento de entrada do inversor. Cada conversor tem seu estudo teÃrico desenvolvido e ao final apÃs as especificaÃÃes e dimensionamentos sÃo mostrados os resultados experimentais do protÃtipo do projeto. Quando o sistema for aproveitado em uma instalaÃÃo fotovoltaica somente o inversor e o conversor boost de alto ganho sÃo utilizados. / The study of the development of initerruptible power supply to be used in a photovoltaic system has as motivation that the wide UPS production scale can reduce the cost of power electronics converters associated with a photovoltaic system. The project proposes a topology of an on-line UPS, with 220 Volts, 60 Hz input/output voltage, 715 VA power, 88% efficiency, High frequency isolation and Power factor correction. The Project consists on a rectifier, it is responsible for providing the input power factor correction and the high frequency isolation. An inverter, it supply the load with a output sinusoidal voltage and a high gain boost converter that increase the voltage from the battery pack up to the inverter. When the project is used in a photovoltaic system, it is only used the inverter and the high gain boost converter.
67

Controle e supervisão de fonte ininterrupta de energia híbrida / Control and supervision of hybrid Uninterrupted power supply

Tibola, Jonas Roberto 13 February 2017 (has links)
This work presents contributions to the modeling, control and management of an hybrid uninterrupted power supply (UPS) based on Otto cycle power generator set and lead acid battery bank. The proposed configuration is called hybrid due to the presence of two energy storage elements: i) the fuel fed the Otto cycle internal combustion engine (ICE) of the generator set and ii) a lead acid battery bank, which can be recharged from the grid or from the generator. With the hybridization it is possible to add up the advantages of UPS’s such as uninterrupted power supply and high output energy quality with the advantages of power generator sets, such as high autonomy and lower installation cost for high autonomy. In addition, with the hybrid topology it is possible to explore degrees of freedom that do not exist in the independent configurations, such as: i) variable speed operation and ii) start-stop operation of the MCI in order to reduce consumption/ emissions in lower loads, (iii) use of Otto cycle engine with lower cost in relation to a Diesel ICE. The hybrid UPS is composed of an Otto cycle internal combustion engine (ICE), a three-phase/three-wire rectifier, which can be connected via contactors to the grid, or to the permanent magnet synchronous generator (PMSG), a battery bank connected to the DC bus through a bi-directional boost converter, and a three-phase/four-wire inverter at the output. Experimental results are provided indicating that variable speed operation can achieve a reduction of up to 32% in specific fuel consumption, depending on the load range. For start-stop operation, the reduction in specific fuel consumption can reach up to 39%, depending on the load range. / Este trabalho apresenta contribuições a modelagem, controle e gerenciamento de uma fonte ininterrupta de energia (UPS) híbrida baseada em grupo motor ciclo Otto e bateria chumbo ácido. A configuração proposta é denominada híbrida devido a presença de dois armazenadores de energia: i) o combustível para alimentar o motor a combustão interna (MCI) ciclo Otto do grupo motor gerador e ii) um banco de baterias chumbo ácido, a qual pode ser recarregado pela rede ou pelo gerador. Com a hibridização é possível agregar as vantagens das UPSs tais como, ininterruptibilidade de fornecimento de energia e alta qualidade de energia da tensão de saída, com as vantagens dos grupos motores geradores, tais como, elevada autonomia e menor custo de instalação para autonomias elevadas. Além disso, com a topologia híbrida é possível explorar graus de liberdade não existentes nas configurações independentes, tais como: i) utilização de velocidade variável e ii) operação em regime start-stop no MCI afim de reduzir consumo/emissões em baixas cargas, iii) utilização de motor ciclo Otto com menor custo em relação a um MCI Diesel. A UPS híbrida é composta por um motor a combustão interna (MCI), um retificador trifásico a três/quatro fios, o qual pode ser conectado através de contatoras à rede, ou ao gerador síncrono de ímãs permanente (PMSG), um banco de baterias conectado ao barramento através de um conversor boost bidirecional, e um inversor a quatro fios na saída. Resultados experimentais são apresentados indicando que a operação em velocidade variável pode alcançar um redução de até 32% no consumo específico de combustível, dependendo a faixa de carga. Já para a operação em regime start-stop a redução no consumo específico de combustível pode alcançar até 39%, dependendo da faixa de carga.
68

Inversores fotovoltaicos conectados à rede com armazenamento de energia – classificação, recomendações técnicas e gerenciamento / Grid-connected photovoltaic energy storage systems – classification, technical recommendations and management

Bellinaso, Lucas Vizzotto 08 March 2017 (has links)
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Grid-connected photovoltaic systems with energy storage have features of conventional gridconnected inverters and uninterruptible power supplies. In these systems, all elements, which include photovoltaic generator, batteries, loads and electric grid, are connected to the same equipment named multifunctional photovoltaic converter. As it is a recent technology, there are many research opportunities in this theme, from classifications and standards to specific problems. This study investigates this field in a comprehensive manner, proposing classifications, technical recommendations and a power management strategy. Initially, classifications are proposed considering system configuration and continuity of supply to the loads. In the following, technical recommendations related to grid and load compatibility, as well as safety technical recommendations, are proposed. The last proposal consists on a power management strategy which defines the operation mode of the static converters and system elements as a function of the energy scarcity. Experimental results of the power management are presented in order to validate the proposals. In this way, this thesis contributes to the development of multifunctional photovoltaic converters technology so that the distributed generation becomes more independent of solar availability and can better collaborate with the electric system. / Sistemas fotovoltaicos conectados à rede com armazenamento de energia são aqueles que conjugam características dos inversores conectados à rede convencionais e de fontes ininterruptas de energia. Nesses sistemas, todos os seus elementos, que incluem o gerador fotovoltaico, as baterias, as cargas e a rede elétrica, são conectados a um mesmo equipamento chamado de conversor fotovoltaico multifuncional. Por se tratar de uma tecnologia recente, existem muitas oportunidades de pesquisa inédita no tema, desde premissas e classificações básicas até a solução de problemas mais específicos. Este trabalho investiga o tema de maneira abrangente, propondo classificações, recomendações técnicas e uma estratégia para gerenciamento interno de potência dos conversores fotovoltaicos multifuncionais. Inicialmente, classificações são propostas considerando a configuração do sistema e a continuidade de fornecimento de energia às cargas. A seguir, são propostas recomendações técnicas relacionadas à compatibilidade com a rede e com as cargas, além de recomendações técnicas de segurança, baseando-se em normas existentes. A última proposta consiste em uma estratégia de gerenciamento interno de potência que define os modos de operação dos conversores estáticos e dos elementos do sistema em função da escassez de energia. Resultados experimentais do método proposto para o gerenciamento interno de potências são apresentados com o objetivo de validar as propostas desenvolvidas. Dessa forma, o presente trabalho contribui com o desenvolvimento da tecnologia de conversores fotovoltaicos multifuncionais, para que a geração distribuída de energia elétrica se torne mais independente da disponibilidade solar e possa melhor colaborar com o sistema elétrico.
69

Desenvolvimento e implementação de um sistema de controle de posição e velocidade de uma esteira transportadora usando inversor de frequência e microcontrolador

Raniel, Thiago [UNESP] 24 May 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-05-24Bitstream added on 2014-06-13T19:27:59Z : No. of bitstreams: 1 raniel_t_me_ilha.pdf: 1815527 bytes, checksum: 2b9558bcbd56601c8cbb627feda891cf (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A automação de esteiras rolantes é algo comum e importante em sistemas industriais, mas problemas práticos ainda representam desafios. Um dos desses desafios é manter a precisão em sistemas que exigem paradas sistemáticas, pois folgas mecânicas tendem a provocar variações nas posições de paradas ao longo do tempo. A aplicação de motores de indução têm se tornado comum e soluções eficientes e de baixo custo têm sido pesquisadas. Neste trabalho foi desenvolvido e implementado um sistema de controle de posição e velocidade aplicado em esteiras transportadoras utilizando inversor de frequência, microcontrolador, encoder óptico incremental e sensor indutivo. O movimento da esteira transportadora é efetuado por um motor de indução trifásico, que é acionado pelo conjunto microcontrolador – inversor de frequência. Este conjunto impõe uma frequência no estator do motor através de uma troca de mensagens entre microcontrolador e inversor de frequência (Sistema Mestre-Escravo). Para o envio e recebimento das mensagens, utilizou-se o protocolo de comunicação serial USS® (Universal Serial Interface Protocol) através do padrão RS-485. Os controles de posição e velocidade de rotação do eixo do motor fundamentam-se no sinal gerado pelo encoder óptico incremental, responsável por informar a posição do eixo do motor ao longo da trajetória, e no sensor indutivo que determina uma referência externa importante para a esteira transportadora. Para o funcionamento automático da esteira, elaborou-se um software em linguagem de programação C. Como resultado obteve-se um sistema de controle de posição e velocidade do eixo do motor de indução trifásico que apresenta bons resultados / Automated conveyors system have been largely used in industrial applications. However, there are still practical issues to be overcome. One of them is due to the system mechanical limitation which can lead to low accuracy for applications based on “stop-and-go” movements. Induction motors have been largely used in such applications and low costs solutions have been searched. In this work it was developed and implemented a system of positioning and velocity control applied to conveyors which is based on frequency inverter, microcontroller, optical incremental encoder and inductive sensor. The conveyor’s movement is made by means of a three-phase induction motor, which is driven by the couple microcontroller–frequency inverter. There are messages exchange between the microcontroller and the frequency inverter (Master – Slave configuration) which is based on the communication serial protocol USS through the RS-485 standard. The position and velocity of the motor spindle are controlled using an optical incremental encoder, which is responsible to provide the position of the trajectory, and an inductive sensor which determines the initial reference to the conveyor. The software used to control the system was developed in C language. The results show a low cost system with good results
70

Modelagem, análise e experimentação de sistema fotovoltaico isolado baseado em plataforma de simulação com diagrama de blocos.

Santos Junior, Francisco Antonio Ferreira dos 29 February 2016 (has links)
Submitted by Morgana Silva (morgana_linhares@yahoo.com.br) on 2016-07-26T18:10:50Z No. of bitstreams: 1 arquivototal.pdf: 2752063 bytes, checksum: 886fc73f7f66099f1e033937798f6b7e (MD5) / Made available in DSpace on 2016-07-26T18:10:50Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2752063 bytes, checksum: 886fc73f7f66099f1e033937798f6b7e (MD5) Previous issue date: 2016-02-29 / This paper presents a block diagram modeling of a grid-independent photovoltaic power generation system, including the steps of DC regulation, voltage inversion, and control system based on dynamic simulations in Simulink / Matlab® exclusively using the built-in blocks available in its library. A well-known technique in literature called MPPT (maximum power point tracking) was used for tracking the maximum power of the photovoltaic generation. However, the control that was used to maintain a constant output voltage of the Push-Pull is based on a method that is similar to the MPPT, which configures a novelty of this research. The integration of modeling the entire PV system with these control systems is carried out in Simulink for investigaton and production of simulation results. An experimental platform that includes an emulator of photovoltaic panels, a 1 kW Push-Pull converter, a three-phase inverter with three arms and a hydraulic load constituided by a motor-pump was built in the laboratory. The experimental results corroborate the methodology that was used. / Este trabalho apresenta uma modelagem em diagramação de blocos de um sistema de geração de energia fotovoltaico isolado, incluindo as etapas de regulação CC, inversão de tensão e sistema de controle com base em simulações dinâmicas no ambiente Simulink/Matlab® utilizando, exclusivamente, os blocos built-in disponíveis em sua biblioteca. Uma técnica bem conhecida na literatura foi utilizada para o rastreio da máxima potência da geração fotovoltaica. No entanto, o controle utilizado para manter a tensão de saída constante do Push-Pull é baseado num método similar ao do rastreio da máxima potência, o que configura uma novidade deste trabalho. A integração da modelagem de todo o sistema fotovoltaico com estes sistemas de controle é realizada no ambiente Simulink para averiguação e produção dos resultados de simulação. Uma plataforma experimental que inclui um emulador de painéis fotovoltaicos, um Push-Pull de 1 kW de potência, um inversor trifásico de três braços e uma carga hidráulica constituída por um motobomba foi construída em laboratório. Os resultados experimentais corroboram a metodologia utilizada.

Page generated in 0.1527 seconds