• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 19
  • 4
  • 2
  • 2
  • 1
  • Tagged with
  • 59
  • 59
  • 19
  • 11
  • 10
  • 10
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Využití vysoce účinné iontové chromatografie ve farmaceutické analýze organických aniontů a kationtů / Pharmaceutical application of high performance ion chromatography in analysis of organic anions and cations

Čujová, Sabína January 2010 (has links)
The thesis is focused on application of ion chromatography in pharmaceutical analyses of organic ions. Ion chromatography is increasingly used in the field of pharmaceutical analysis. This includes the analysis of impurities and metabolites. In the first part of this thesis, ion chromatography is compared with common separation techniques used in pharmacy, such as gas chromatography and high performance liquid chromatography. In the second part development and validation of methods of ion chromatography for purity evaluation and quality control of active pharmaceutical substances Rivastigmine hemitartrate and Pramipexole hydrochloride were carried out. Key words: ion chromatography, reversed-phase chromatography, ion-pair chromatography, ion-exclusion chromatography, ion-exchange chromatography, GC, HPLC
12

[en] DEVELOPMENT OF AN ANALYTICAL METHOD FOR THE DETERMINATION OF TMSB, SB(V) AND SB(III) IN CLINICAL SAMPLES BY IC-ICPMS / [pt] DESENVOLVIMENTO DE UMA METODOLOGIA PARA DETERMINAÇÃO DE TRIMETIL ANTIMÔNIO, SB(V) E SB(III) EM AMOSTRAS CLÍNICAS POR IC-ICPMS

FLAVIA DE ALMEIDA VIEIRA 03 February 2004 (has links)
[pt] A administração de antimoniais no tratamento da leishmaniose é uma rara oportunidade para estudar o metabolismo de antimônio e das suas espécies químicas. Tais estudos são de grande relevância, uma vez que não se tem conhecimento sobre os metabólitos formados no corpo humano e da sua possível importância na erradicação dos parasitas causadoras da doença, assim como sobre os mecanismos de eliminação deste elemento tóxico. Ao contrário do arsênio, existem poucas metodologias reportadas para a análise de especiação de antimônio em amostras clínicas. O presente trabalho é uma continuação de pesquisas realizadas e publicadas anteriormente, nas quais a técnica de espectrometria de massas (ICPMS) acoplada à cromatografia iônica de alta eficiência IC-(HPLC) foi utilizada para separação e quantificação, em linha, de antimoniato de N-metil glucamina, Sb(V) e Sb(III) em amostras de plasma e urina. Assim, serão apresentados resultados recentes obtidos com o emprego de uma coluna com melhor resolução (Metrosep - A Supp5; 250 mm x 4,0 mm; Metrohm, Suíça) na separação de trimetil antimônio (TMSb), Sb(V) e Sb(III). Testes de otimização mostraram que uma solução de EDTA (0,006 mol L-1, pH 4,7) é adequada como fase móvel para a separação das três espécies. Os tempos de retenção para TMSb, Sb(V) e Sb(III) foram de 44,2 s, 150,6 s e 548,4 s, respectivamente, permitindo uma perfeita e repetitiva (DPR <3 por cento) separação dessas espécies. Repetitividades melhores que 4 por cento foram também obtidas na quantificação das áreas dos três picos cromatográficos correspondentes. Curvas analíticas, construídas a partir de soluções padrão das espécies em solução aquosa e em amostras de urina fortificadas, apresentaram ótima linearidade com coeficientes de correlação maiores que 0,999. Para volumes de amostra de 100 uL, injetados na coluna e utilizando-se o espectrômetro ELAN 5000 (PE-Sciex, EUA) como detector multielementar, em combinação com o nebulizador concêntrico tipo Meinhard e uma câmara ciclônica, limites absolutos de quantificação de 0,02 ng de antimônio foram obtidas para as três espécies estudadas. Testes de estabilidade mostraram que Sb(V) sofre alterações químicas já em intervalos de tempo relativamente curtos (maiores que 8h em água, e que 4h em urina fortificada) enquanto que TMSb e Sb(III) evidenciaram estabilidades consideravelmente maiores em ambos os meios. / [en] Clinical applications of antimonials in the treatment of leishmaniasis are a unique opportunity to study the metabolism of antimony and its species in the human body. As little is known about antimony metabolism, studies are required to improve the knowledge about the excretion mechanism of this toxic element; in particular, those which deal with antimony metabolites and the action of antimonials for the eradication of leishmaniasis causing parasites. In contrast with its chemical analogue arsenic, only a few methods concerning antimony speciation in clinical samples have been described in the literature. The aim of the present work was to improve a method previously developed to separate and quantify N-methyl meglumine antimoniate, Sb(V) and Sb(III) in blood plasma and urine samples by using anion exchange high performance liquid chromatography (IC-HPLC) coupled with inductively-coupled plasma mass spectrometry (ICPMS). Results on the application of an ion chromatography column (Metrosep - A Supp5; 250 mm x 4.0 mm; Metrohm, Swiss) with better resolution for the separation of TMSb, Sb(V) and Sb(III) are presented. The optimum conditions for the separation of the three species were established with 0.006 mol L-1 EDTA at pH 4.7 as the mobile phase. The retention times for TMSb, Sb(V) and Sb(III) were 44,2 s, 151,6 s and 548,4 s, respectively. A robust linear relationship between concentration and peak area was obtained for the three species, both, in aqueous standard solutions and spiked urine samples, with an associated correlation factor higher than 0,999. Relative standard deviations below 4 percent have been obtained in the peak area quantification mode. When using the ELAN 5000 (PerkinElmer-Sciex, EUA) equipped with a concentric Meinhard nebulizer in combination with a cyclonic spray chamber as detector, and employing a 100-uL injection loop in the HPLC system, typical absolute limits of quantification were 0.02 ng of Sb for each of the three antimony species studied. Stability tests showed that Sb(V) suffers chemical alterations within a short time period (>8h in aqueous solutions and >4h in spiked urine), whereas TMSb and Sb(III) presented better stability conditions in both solutions.
13

Estudo preliminar da determinação de amônio por cromatografia de íons e sua remoção em lixiviados de resíduos sólidos utilizando argilas / Preliminary study of ammonium determination by ion chromatography and its removal in leachates from solid waste using clay

Rafael Schirmer de Paula Couto 25 February 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A quantidade de resíduos gerados tem crescido rapidamente, sendo maior que a taxa de crescimento populacional, indicando um aumento na geração per capita. Este fato torna preocupante a maneira como é realizada a disposição final de resíduos e o impacto ambiental gerado com isso. Dentre os impactos está a produção de chorume, um poluente de elevada carga orgânica com altas concentrações de amônio e forte coloração, produzido pela decomposição química e microbiológica dos resíduos sólidos depositados em um aterro. Em locais de destino como aterros sanitários, este chorume é drenado para tratamento a fim de não impactar o local onde foi implantado o aterro. Porém, no Brasil, em grande parte dos casos, este tratamento não acontece, deixando o ambiente mais suscetível à contaminação. Este trabalho teve como finalidade determinar a quantidade de amônio presente em amostras de chorume do aterro de Gramacho no Rio de Janeiro, utilizando a cromatografia de íons para a sua quantificação, além de estudar a remoção de amônio por processos de adsorção em materiais como argilominerais. As amostras de chorume in natura apresentaram valores de pH em torno de 8,0 e concentrações de amônio entre 1665,0 e 2788,8 mg.L-1. Nas amostras analisadas após a destilação do chorume foram encontrados valores de pH entre 8,6 e 9,7 e concentrações de amônio de até 6362,3 mg.L-1, verificando que a maior concentração deste íon é arrastada nos primeiros 50 mL da destilação. Os testes de adsorção obtiveram um potencial de remoção de até 47 % do total de amônio. A metodologia aplicada se mostrou eficiente para determinação de amônio, uma vez que o tratamento prévio minimiza a ação de interferentes. Os baixos valores de remoção de amônio reforçam a necessidade de maior aprofundamento deste estudo, o que seria uma alternativa interessante para minimizar a ação deste poluente no meio ambiente / The amount of waste generated has grown rapidly, being larger than the population growth rate, indicating an increase in per capita generation becoming worrisome, as the final disposal of waste is performed and environmental impact. Among the impacts, is the production of leachate, a high organic pollutant with high concentrations of ammonium and strong staining, produced by chemical and microbiological decomposition of solid waste deposited in a landfill. In destinations such as landfills, the leachate is drained to the treatment to minimize the impact at the local landfill where it was deployed. However, in Brazil, in most cases, this treatment does not happen, leaving the environment more susceptible to contamination. This study aimed to determine the amount of ammonium present in samples of leachate from Gramacho landfill in Rio de Janeiro, using ion chromatography for its quantification, and perform a preliminary study of ammonium removal by adsorption processes in materials as clay minerals. The samples of fresh leachate had pH values around 8.0 and ammonium concentrations between 1665.0 and 2788.8 mg.L-1. In samples analyzed after the leachate distillation were found pH between 8.6 and 9.7 and ammonium concentrations of up to 6362.3 mg.L-1, noting that the largest concentration of this ion is drawn in the first 50 mL of distillation. The adsorption tests had a potential to remove up to 47 % of total ammonia. The methodology is efficient for determination of ammonium, since the pretreatment minimizes the action of interfering components. The low levels of ammonium removal reinforce the need for more study, which would be an interesting alternative to minimize the action of this pollutant in the environment
14

Glutamic Acid Resorcinarene-based Molecules and Their Application in Developing New Stationary Phases in Ion Chromatography

Panahi, Tayyebeh 01 June 2016 (has links)
Resorcinarenes can be functionalized at their upper and lower rims. In this work, the upper rim of a resorcinarene was functionalized with glutamic acids and the lower rim was functionalized with either methyl or undecyl alkyl groups. The cavitands were characterized by nuclear magnetic resonance (NMR), mass spectrometry (MS), UV-vis spectroscopy, dynamic light scattering (DLS) and electron microscopy. The binding of resorcinarene with amine guests was studied in DMSO by UV-vis titration. The obtained binding constants (K values) were in the range of 12,000-136000 M-1. The resorcinarenes were shown to form aggregates in a variety of solvents. The aggregates were spherical as confirmed by DLS, SEM and TEM experiments. Dynamic light scattering (DLS) experiments revealed the size of the aggregates could be controlled by cavitand concentration, pH, and temperature. The resorcinarene with undecyl alkyl group were adsorbed onto 55% cross-linked styrene-divinylbenzene resin to prepare a new stationary phases for ion chromatography (IC) columns. The new column packing material was applied in determination of uremic toxins and water contaminants. The new IC column afforded separation of the five uremic toxins : guanidinoacetic acid, guanidine, methylguanidine, creatinine, and guanidinobenzoic acid in 30 minutes. Detection and quantification of uremic toxins helps diagnose kidney problems and start patient care. Gradient elutions at ambient temperature with methanesulfonic acid (MSA) as eluent resulted in detection levels in water from 10 to 47 ppb and in synthetic urine from 28 to 180 ppb. Trace levels of creatinine (1 ppt) were detected in the urine of a healthy individual using the columns. The new IC stationary phase separated cationic pharmaceuticals including a group of guanidine compounds in surface water. Detection limits in the range of 5 - 32 µg L-1 were achieved using integrated pulsed amperometric detection (IPAD) for guanidine (G), methylguanidine (MG), 1,1-dimethylbiguanidine (DMG), agmatine (AGM), guanidinobenzoic acid (GBA) and cimetidine (CIM). Suppressed conductivity (CD) and UV-vis detection resulted in limits of detection similar to IPAD, in the range of 1.7 - 66 µg L-1, but were not able to detect all of the analytes. Three water sources, river, lake, and marsh, were analyzed and despite matrix effects, sensitivity for guanidine compounds was in the 100 µg L-1 range and apparent recoveries were 80-96 %. The peak area precision was 0.01 - 2.89% for IPAD, CD and UV-vis detection.
15

Separating Acetate, Formate and MSA from natural samples using ion chromatography / Separera Acetat, Format och MSA från naturliga prover med jonkromatografi

Drake, Alexandra January 2013 (has links)
Anjoner från de tre korta organiska syrorna: acetat, format och MSA är intressanta att mäta då de kan användas för olika sorters miljöstudier. Jonkromatografen vid Institutionen för Geovetenskaper kan för närvarande inte skilja på dessa tre ämnen, därför utvecklades sex nya metoder i detta projekt för att lösa problemet. Metod 5 visade sig vara den bästa, där acetat och format separerades. Resultatet ansågs vara bra, även om MSA inte separerades. Metod 5 testades sedan på ett par naturliga prover; vatten-, snö- och isprover. Alla dessa prover visade en större mängd av format än acetat, som i vissa fall inte ens visades. Resultaten verkade rimliga, inte många av dem stack ut i jämförelse till andra resultat av samma fas. Det ytligaste provet från Lomonosovfonnaglaciären skiljer sig dock ganska mycket i mängden format jämfört med prover från andra djup av denna iskärna, förmodligen på grund av kontamination vid hanteringen av proverna både vid provtagningen och i labbet. MSA kan dock även mätas om man vet mängden acetat och format i provet. Detta görs genom tillsats av kända mängder av MSA till samma prov i efterföljande körningar, för att sedan kunna beräkna koncentrationen av MSA i provet. Problemet med denna metod är att koncentrationen av MSA måste vara tillräckligt hög i kontrast till koncentrationerna av acetat och format för att få tillförlitliga resultat, vilket den inte var i det här projektets analyserade prover. / Anions from three short organic acids: acetate, formate and MSA are interesting to measure since they can be used for different environmental studies. The ion-chromatographer at the Department of Earth Sciences is currently not able to separate these three substances; therefore six new methods were developed in this project to solve this problem. Short organic test 5 ended up to be the best method, where acetate and formate were separated. The result was considered good, even if MSA were not separated. Method 5 was then tested on a couple of natural water, snow and ice samples. All these samples showed a larger amount of formate than of acetate, which in some cases was not even found. The results seemed plausible; not many of them were sticking out compared to others of the same phase. The shallowest sample from the Lomonosovfonna ice cap did however differ quite a lot in amount of formate compared with samples from other depths of this ice core; probably because of contamination which could have occurred at both the ice cap and in the lab during the handling of the samples. MSA can however also be measured if the amount of acetate and formate in the sample is known. This is done by adding known amounts of MSA to the same sample in subsequent runs to then be able to calculate the concentration of MSA in the sample. The problem with the use of this method is that the concentration of MSA needs to be high enough in contrast to acetate and formate in order to get reliable results, which was not the case in the samples measured in this project.
16

Reliability Assessment of Ion Contamination Residues on Printed Circuit Board

Nguyen, Minh Tam Tran 01 January 2013 (has links)
Ion contaminants from Printed Circuit Board (PCB) assembly processes pose a high reliability risk because they result in damaged circuits. Therefore, it is essential to understand the level of ionic species on the electronic circuitry as well as the reliability risks caused by these contaminants. There are a number of approaches available in the industry to assess the reliability risks ; for example, the water drop test (WDT) is one of the techniques used to determine the propensity of an ionic contaminant to cause electrical short failures by dendrite formation. The objective of this research is to determine the time to cause the failures, known as electrochemical migration (ECM) failures. A test vehicle was developed for the WDT to obtain the time to cause ECM failure in presence of different anions. The time to form dendritic bridges that cause short circuits was determined as a function of the different anions and the spacings between PCB pads. The experimental method involved dispensing aqueous solutions containing common inorganic and organic acid anions onto test vehicles, applying electrical bias voltages and measuring the time to form dendrites. Specially designed test structures cells were created to contain the test solutions. At each of the test cells, a cavity held the solution and constant current was applied through different metal geometries. To be representative of popular board finishes, test vehicle boards incorporated both Sn-Pb Hot Air Soldering Level (HASL) and Pb free HASL surface finishes.
17

Caracterização de íons majoritários presentes no material particulado atmosférico do entorno da Baía de Todos os Santos-BA

Silva, José Domingos Santos da January 2011 (has links)
106 f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-03T14:21:08Z No. of bitstreams: 4 SUMÁRIO.pdf: 251853 bytes, checksum: 136967f071e8c9dc1f1d9dc61b6ba5ed (MD5) RESUMO.pdf: 90333 bytes, checksum: 6feb676556b5519091aca62ba1aef7f9 (MD5) INTRODUÇÃO.pdf: 4006502 bytes, checksum: 77f35936fb80d965a1c446cf7b35deed (MD5) CAPA.pdf: 247759 bytes, checksum: 0319a707474146fc6565e0c7806729e3 (MD5) / Rejected by Ana Hilda Fonseca(anahilda@ufba.br), reason: Solicito o envio em arquivo único. on 2013-04-18T15:44:07Z (GMT) / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-05-20T15:25:26Z No. of bitstreams: 1 Dissertação José Domingos S da Silva.pdf: 4188732 bytes, checksum: 5a2a0590c7239c937525ccc66385274d (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-05-20T15:27:50Z (GMT) No. of bitstreams: 1 Dissertação José Domingos S da Silva.pdf: 4188732 bytes, checksum: 5a2a0590c7239c937525ccc66385274d (MD5) / Made available in DSpace on 2013-05-20T15:27:50Z (GMT). No. of bitstreams: 1 Dissertação José Domingos S da Silva.pdf: 4188732 bytes, checksum: 5a2a0590c7239c937525ccc66385274d (MD5) Previous issue date: 2011 / CAPES / Um grande número de estudos epidemiológicos tem mostrado uma relação entre a exposição ao ambiente de partículas em suspensão e os efeitos adversos na saúde humana além de danos à flora, fauna, edificações dentre outros. Segundo alguns estudos o MPA afeta a saúde da população, causando várias patologias do trato respiratório (alergias, asma, enfisema pulmonar) e mortalidade cardiopulmonar, sendo responsável por grande numero de mortes em todo o mundo. Este trabalho teve por objetivo desenvolver e validar metodologia para determinação de íons presentes nas frações PM1 e PM2,5 no Material Particulado Atmosférico da atmosfera do entorno da Baía de Todos os Santos (BTS). Durante o desenvolvimento do trabalho foram coletadas amostras de MPA com a utilização de dois amostradores tipo ciclone com faixa de corte de PM1 e PM2,5 ligados a uma bomba de vácuo a uma vazão fixa de 10L min-1 por períodos de 12h durante 15 dias em três sítios de amostragem nos seguintes períodos: Botelho, Base Naval de Aratu (BNA) e Itaparica. As amostras coletadas foram coletadas e depois analisadas por cromatografia de íons com dois canais. Os íons determinados nos três sítios foram lactato, acetato, butirato, formiato, succinato, oxalato, amônio, fluoreto, cloreto, nitrato, sulfato, fosfato, sódio, potássio, magnésio e cálcio, a seguinte relação entre ânions e cátions nas frações PM1 e PM2,5. Dentre os três sítios o que apresentou maiores concentrações médias destes íons foi Botelho, isso ocorreu devido a sua posição geográfica em relação aos ventos que sopram nesta região durante a estação de inverno na qual as amostras foram coletadas as concentrações menores foram no sitio da BNA por estar em posição geográfica oposta em relação aos ventos. Para todos os sítios a relação iônica equivalente (ânions/cátions) sempre foi maior que um o que mostra que há mais cátions que ânions e, portanto, trata-se de caráter ácido. No sitio de Botelho foi encontrado um prevalência de íons emitidos por fontes industriais, ressuspensão de partículas, por emissão da flora e fonte secundaria. Em BNA houve prevalência de queima de combustível. Em Itaparica houve prevalência de emissões veiculares e de ressuspensão de partículas. / Salvador
18

Avaliação do tratamento de efluentes sintéticos com glifosato por osmose inversa / Evaluation of syntetic effluent treatment with glyphosate by reverse osmosis

Alexandre Luís de Azevedo Santos 28 February 2013 (has links)
O presente trabalho avaliou a capacidade do sistema de osmose inversa de bancada na remoção de glifosato, em soluções de efluente aquoso sintético, empregando membrana de poliamida. Os parâmetros empregados para esta avaliação foram a pressão, o fluxo de alimentação, o tempo de operação, o pH e a concentração de glifosato na solução de alimentação em que os mesmos foram variados de modo a se ter um comparativo entre diferentes níveis. O sistema de osmose inversa teve em todos os experimentos uma boa resposta quanto a rejeição de glifosato em que a mesma variou entre 74,2% a 98,6 %, sendo a máxima atingida em condições de pressão em 30 bar, fluxo de alimentação 1 L.min-1 e pH 11 da solução de alimentação. A resposta do sistema foi avaliada quanto ao fluxo de permeado, de rejeição percentual e concentração de glifosato no permeado. O efeito da variação de concentração sobre a rejeição de glifosato foi pouco efetiva, mas apresentou grande influência quanto à variação de concentração deste no permeado. Ainda foi avaliada a remoção do ácido aminometilfosfônico (AMPA), pelo sistema de osmose inversa, obtendo-se uma boa resposta quanto à rejeição atingindo valores em torno de 95%. Uma solução combinada de AMPA e glifosato foi preparada e processada no sistema de osmose inversa, obtendo-se resposta similar quanto à concentração de permeado e rejeição para ambos os compostos. A quantificação de AMPA e glifosato se deu por cromatografia de íons, onde esta técnica se mostrou robusta e simples para quantificar ambos os compostos em meio aquoso, em baixas concentrações / This work evaluated the capacity of the reverse osmosis system bench in removing glyphosate from aqueous effluent synthetic solutions, employing polyamide membrane. The parameters used for this evaluation were the pressure, the feed stream, operating time, pH and concentration of glyphosate in feed solution in which they were varied in so as to have one comparison between different levels. The reverse osmosis system in all experiments had a good reply regarding rejection of glyphosate in that the same ranged between 74.2% and 98.6%, with a maximum reached under conditions of pressure 30 bar, feed stream 1 liters per minute and pH 11 of the feed solution. The system response was evaluated with respect to permeate flux, rejection and percent concentration of glyphosate in permeate. The concentration variation effect about the rejection of glyphosate was little effective, but had a great influence as to variation of the concentration in permeate. Also evaluated was the removal of aminomethylphosphonic acid (AMPA), in the reverse osmosis system, obtaining a good response regarding rejection reaching values around 95%. A combined solution of glyphosate and AMPA was prepared and processed in reverse osmosis system, obtaining a similar response regarding the concentration of permeated and rejection for both compounds. Quantitation of glyphosate and AMPA was made by ion chromatography, where the technique was demonstrated robust and easy to quantify both compounds in aqueous at low concentrations
19

Estudo preliminar da determinação de amônio por cromatografia de íons e sua remoção em lixiviados de resíduos sólidos utilizando argilas / Preliminary study of ammonium determination by ion chromatography and its removal in leachates from solid waste using clay

Rafael Schirmer de Paula Couto 25 February 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A quantidade de resíduos gerados tem crescido rapidamente, sendo maior que a taxa de crescimento populacional, indicando um aumento na geração per capita. Este fato torna preocupante a maneira como é realizada a disposição final de resíduos e o impacto ambiental gerado com isso. Dentre os impactos está a produção de chorume, um poluente de elevada carga orgânica com altas concentrações de amônio e forte coloração, produzido pela decomposição química e microbiológica dos resíduos sólidos depositados em um aterro. Em locais de destino como aterros sanitários, este chorume é drenado para tratamento a fim de não impactar o local onde foi implantado o aterro. Porém, no Brasil, em grande parte dos casos, este tratamento não acontece, deixando o ambiente mais suscetível à contaminação. Este trabalho teve como finalidade determinar a quantidade de amônio presente em amostras de chorume do aterro de Gramacho no Rio de Janeiro, utilizando a cromatografia de íons para a sua quantificação, além de estudar a remoção de amônio por processos de adsorção em materiais como argilominerais. As amostras de chorume in natura apresentaram valores de pH em torno de 8,0 e concentrações de amônio entre 1665,0 e 2788,8 mg.L-1. Nas amostras analisadas após a destilação do chorume foram encontrados valores de pH entre 8,6 e 9,7 e concentrações de amônio de até 6362,3 mg.L-1, verificando que a maior concentração deste íon é arrastada nos primeiros 50 mL da destilação. Os testes de adsorção obtiveram um potencial de remoção de até 47 % do total de amônio. A metodologia aplicada se mostrou eficiente para determinação de amônio, uma vez que o tratamento prévio minimiza a ação de interferentes. Os baixos valores de remoção de amônio reforçam a necessidade de maior aprofundamento deste estudo, o que seria uma alternativa interessante para minimizar a ação deste poluente no meio ambiente / The amount of waste generated has grown rapidly, being larger than the population growth rate, indicating an increase in per capita generation becoming worrisome, as the final disposal of waste is performed and environmental impact. Among the impacts, is the production of leachate, a high organic pollutant with high concentrations of ammonium and strong staining, produced by chemical and microbiological decomposition of solid waste deposited in a landfill. In destinations such as landfills, the leachate is drained to the treatment to minimize the impact at the local landfill where it was deployed. However, in Brazil, in most cases, this treatment does not happen, leaving the environment more susceptible to contamination. This study aimed to determine the amount of ammonium present in samples of leachate from Gramacho landfill in Rio de Janeiro, using ion chromatography for its quantification, and perform a preliminary study of ammonium removal by adsorption processes in materials as clay minerals. The samples of fresh leachate had pH values around 8.0 and ammonium concentrations between 1665.0 and 2788.8 mg.L-1. In samples analyzed after the leachate distillation were found pH between 8.6 and 9.7 and ammonium concentrations of up to 6362.3 mg.L-1, noting that the largest concentration of this ion is drawn in the first 50 mL of distillation. The adsorption tests had a potential to remove up to 47 % of total ammonia. The methodology is efficient for determination of ammonium, since the pretreatment minimizes the action of interfering components. The low levels of ammonium removal reinforce the need for more study, which would be an interesting alternative to minimize the action of this pollutant in the environment
20

Avaliação do tratamento de efluentes sintéticos com glifosato por osmose inversa / Evaluation of syntetic effluent treatment with glyphosate by reverse osmosis

Alexandre Luís de Azevedo Santos 28 February 2013 (has links)
O presente trabalho avaliou a capacidade do sistema de osmose inversa de bancada na remoção de glifosato, em soluções de efluente aquoso sintético, empregando membrana de poliamida. Os parâmetros empregados para esta avaliação foram a pressão, o fluxo de alimentação, o tempo de operação, o pH e a concentração de glifosato na solução de alimentação em que os mesmos foram variados de modo a se ter um comparativo entre diferentes níveis. O sistema de osmose inversa teve em todos os experimentos uma boa resposta quanto a rejeição de glifosato em que a mesma variou entre 74,2% a 98,6 %, sendo a máxima atingida em condições de pressão em 30 bar, fluxo de alimentação 1 L.min-1 e pH 11 da solução de alimentação. A resposta do sistema foi avaliada quanto ao fluxo de permeado, de rejeição percentual e concentração de glifosato no permeado. O efeito da variação de concentração sobre a rejeição de glifosato foi pouco efetiva, mas apresentou grande influência quanto à variação de concentração deste no permeado. Ainda foi avaliada a remoção do ácido aminometilfosfônico (AMPA), pelo sistema de osmose inversa, obtendo-se uma boa resposta quanto à rejeição atingindo valores em torno de 95%. Uma solução combinada de AMPA e glifosato foi preparada e processada no sistema de osmose inversa, obtendo-se resposta similar quanto à concentração de permeado e rejeição para ambos os compostos. A quantificação de AMPA e glifosato se deu por cromatografia de íons, onde esta técnica se mostrou robusta e simples para quantificar ambos os compostos em meio aquoso, em baixas concentrações / This work evaluated the capacity of the reverse osmosis system bench in removing glyphosate from aqueous effluent synthetic solutions, employing polyamide membrane. The parameters used for this evaluation were the pressure, the feed stream, operating time, pH and concentration of glyphosate in feed solution in which they were varied in so as to have one comparison between different levels. The reverse osmosis system in all experiments had a good reply regarding rejection of glyphosate in that the same ranged between 74.2% and 98.6%, with a maximum reached under conditions of pressure 30 bar, feed stream 1 liters per minute and pH 11 of the feed solution. The system response was evaluated with respect to permeate flux, rejection and percent concentration of glyphosate in permeate. The concentration variation effect about the rejection of glyphosate was little effective, but had a great influence as to variation of the concentration in permeate. Also evaluated was the removal of aminomethylphosphonic acid (AMPA), in the reverse osmosis system, obtaining a good response regarding rejection reaching values around 95%. A combined solution of glyphosate and AMPA was prepared and processed in reverse osmosis system, obtaining a similar response regarding the concentration of permeated and rejection for both compounds. Quantitation of glyphosate and AMPA was made by ion chromatography, where the technique was demonstrated robust and easy to quantify both compounds in aqueous at low concentrations

Page generated in 0.0859 seconds