• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Studies of Singly and Multiply Charged Secondary Ion Emission And The Effects Of Oxygen On Ionization And Sputter Erosion

January 2012 (has links)
abstract: Mass spectrometric analysis requires that atoms from the sample be ionized in the gas phase. Secondary ion mass spectrometry achieves this by sputtering samples with an energetic primary ion beam. Several investigations of the sputtering and ionization process have been conducted. Oxygen is commonly used in secondary ion mass spectrometry (SIMS) to increase ion yields, but also can complicate the interpretation of SIMS analyses. An 18O implant in silicon has been used to quantify the oxygen concentration at the surface of sputtered silicon in order to study the dependence on oxygen of several sputtering and depth profile phenomena. The ion yield dependence of trace elements in silicon on the surface oxygen concentration is a function of the ionization potential of the element. The ion yield is high and unaffected by oxygen for elements with low ionization potential and ranges over several orders of magnitude for elements with high ionization potential. Depth resolution in sputter profiles has been shown to be degraded by the presence of oxygen, the mechanism of this effect has been investigated using an 18O implant to quantify oxygen levels and it is shown that the process does not appear to be a consequence of surface oxide formation. Molecular ions are a source of mass interference in SIMS analysis, and multiply charged atomic ion signals might be interference-free due to the possible instability of multiply-charged molecular ions. Sputtered SiH2+, AlH2+, BeH2+, Mo22+ and Mg22+ ions have been observed and appear surprisingly stable. The formation mechanism of some of these species has been explored. / Dissertation/Thesis / Ph.D. Chemistry 2012
2

Explorations of Functionalized Gold Nanoparticle Surface Chemistry for Laser Desorption Ionization Mass Spectrometry Applications

Gomez Hernandez, Mario 1980- 02 October 2013 (has links)
Functionalized nanoparticles provide a wide range of potential applications for Biological Mass Spectrometry (MS). Particularly, we have studied the effects of chromophore activity on the performance of gold nanoparticles (AuNPs) capped with substituted azo (-N=N-) dyes for analyte ion production in Laser Desorption Ionization Mass Spectrometry (LDI-MS) conditions. A series of aromatic thiol compounds were used as Self-Assembled Monolayers (SAM) to functionalize the surface of the AuNPs. Results indicate that AuNPs functionalized with molecules having an active azo chromophore provide enhanced analyte ion yields than the nanoparticles capped with the hydrazino analogs or simple substituted aromatic thiols. We have also conducted experiments using the azo SAM molecules on 2, 5, 20, 30, and 50 nm AuNPs exploring the changes of Relative Ion Yield (RIY) with increased AuNP diameters. Our results indicate that the role of the SAM to drive energy deposition decreases as the size of the AuNP increases. It was determined that 5 nm is the optimum size to exploit the benefits of the SAM on the ionization and selectivity of the AuNPs.

Page generated in 0.0495 seconds