• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Visiška kairiosios Hiso pluošto kojytės blokada ir vainikinių arterijų angiografijos daugiapjūviu kompiuteriniu tomografu tyrimo vertė / Performance of the multislice computed tomography angiography of the coronary arteries in patients with complete left bundle branch block

Jankauskas, Antanas 22 April 2010 (has links)
Vainikinių arterijų tyrimas daugiapjūviu kompiuteriniu tomografu (DKT) į klinikinę praktiką įdiegtas nesenai. Tai neinvazyvus tyrimo metodas, kurį galima atlikti ir ambulatoriniams pacientams. Tačiau greta savo privulumų, jis turi ir trūkumų – dėl nuolatinio vainikinių arterijų judėjimo širdies ciklo metu gali atsirasti liekamųjų judesio artefaktų atkuriant vaizdus. Jų tikimybė priklauso ne tik nuo aparato, kuriuo atliekamas tyrimas, techninių charakteristikų, bet ir nuo širdies veiklos ypatumų. Yra atlikta nemažai tyrimų, įvertinančių vainikinių arterijų vaizdų kokybės priklausomybę nuo širdies susitraukimų dažnio, jo variabilumo, kitų faktorių. Kairiosios Hiso pluošto kojytės blokados, sąlygojančios nesinchronišką skilvelių susitraukimą ir atsipalaidavimą, įtaka vaizdų kokybei tyrinėta mažai. Šiame tyrime buvo palyginta vaizdų kokybė tarp pacientų, kuriems nustatyta visiška kairiosios Hiso pluošto kojytės blokada ir nėra laidžiosios sistemos sutrikimų, grupių. Analizuota vainikinių arterijų įvertinimo visuose širdies ciklo rekonstrukciniuose intervaluose įtaka vaizdų kokybės vidurkiui. Nustatyta, kokia yra DKT tyrimo diagnostinė vertė identifikuojant hemodinamiškai reikšmingas vainikinių arterijų stenozes. Kadangi DKT tyrimas susijęs su jonizuojančia spinduliuote, įvertinti rentgeno vamzdžio srovės stiprumo moduliavimo ypatumai. Taip pat nustatyta širdies susitraukimų dažnio, jo variabilumo įtaka vaizdų kokybei, esant visiškai kairiosios Hiso pluošto kojytės blokadai. / Multislice computed tomography (MSCT) coronary angiography is one of the latest usage area of the computed tomography technology. It s a non-invasive diagnostic tool, wich can be performed in ambulant patients. MSCT coronary angiography beside it's advantages has some drawbacks. The main drawbacks are lower spatial resolution and residual motion artifacts in MSCT images. Therefore quality of coronary images and diagnostic value of MSCT angiography differs, depending on patient's clinical characteristics, especially on heart contraction features during scanning. Asynchronic contraction and relaxation of the right and left ventricles, caused of bundle branch block can also influence image quality of MSCT coronary angiography. To date, there are only few studies, conducted to analyse diagnostic performance of MSCT coronary angiography in patients with left bundle branch block. Although influence of heart rate, heart rate variability and the other factors (for example, age, sex, body mass index) on MSCT image quality are quite well investigated. Thus, the present study were designed to investigate the influence of complete left bundle branch block on image quality of MSCT coronary angiography more detail in comparison with control patients group without electrical conduction disturbances, reveal the diagnostic value of MSCT angiography to identify hemodinamicaly significant coronary stenosis.
2

Lietuvoje besiveisiančių usūrinių šunų (Nyctereutes procyonoides) ir rudųjų lapių (Vulpes vulpes) skeleto morfologinė analizė / Skeletal morphological analysis of raccoon dogs (Nyctereutes procyonoides) and red foxes (Vulpes vulpes) in Lithuania

Jurgelėnas, Eugenijus 11 May 2010 (has links)
Darbo tikslas: atlikti palyginamąją rudųjų lapių ir usūrinių šunų kaukolių, ilgųjų ir plokščiųjų galūnių kaulų osteologinę ir osteometrinę analizę. Darbo uždaviniai: 1. Išmatuoti ir palyginti usūrinių šunų ir rudųjų lapių patinų ir patelių kaukoles su apatiniais žandikauliais, krūminius dantis, plokščiuosius galūnių kaulus – mentę ir dubens kaulus ir ilguosius galūnių kaulus – petikaulį, dilbio kaulus, šlaunikaulį ir blauzdos kaulus. 2. Naudojantis gautais matmenimis atlikti tarprūšinį usūrinių šunų ir rudųjų lapių kaukolių su apatiniais žandikauliais, krūminių dantų, plokščiųjų galūnių kaulų – mentės ir dubens kaulų ir ilgųjų galūnių kaulų – petikaulio, dilbio kaulų, šlaunikaulio ir blauzdos kaulų palyginimą. 3. Apskaičiuoti kaukolių ir nurodytų ilgųjų galūnių kaulų – petikaulio, stipinkaulio, šlaunikaulio ir blauzdikaulio indeksus ir atlikti šių indeksų palyginimą tarp lyčių ir tarp tirtų gyvūnų rūšių. 4. Atlikti tarprūšinį kaukolių su apatiniais žandikauliais, plokščiųjų galūnių kaulų – mentės ir dubens kaulų, ilgųjų galūnių kaulų – petikaulio, dilbio kaulų, šlaunikaulio ir blauzdos kaulų morfologinį tyrimą palyginamosios anatomijos metodu. 5. Nustatyti tarprūšinius rudųjų lapių ir usūrinių šunų kaukolių vidinių struktūrų ir kaktikaulio ančių morfologinius ypatumus naudojant kompiuterinės tomografijos metodą. Pirmą kartą Lietuvoje atlikta palyginamoji usūrinių šunų ir rudųjų lapių kaukolių ir galūnių kaulų morfologinė analizė. Laukinės faunos osteologiniuose tyrimuose... [toliau žr. visą tekstą] / The aim of the present study is: to carry out a comparative osteological and osteometric analysis of skulls and long and flat bones of extremities of red foxes and raccoon dogs. The tasks include: 1. Measuring and comparison of the bones of male and female red foxes and raccoon dogs: skulls with jawbones, molars, the flat bones of extremities – scapula and pelvic bones – and the long bones of extremities – humerus, forearm, femur and crural bone. 2. Comparison of the bones of raccoon dogs and red foxes based on the obtained osteometric data about: skulls with jawbones, molars, the flat bones of extremities – scapula and pelvic bones – and the long bones of extremities – humerus, forearm bones, femur and crural bone. 3. Calculation of the indices of skulls and the indicated long bones of extremities – humerus, radius, femur and tibia – and comparison of these indices in the studied animals of different gender and species. 4. Morphological analysis of the bones – skulls with jawbones, the flat bones of extremities (scapula and pelvic bones) and the long bones of extremities (humerus, forearm, femur and crural bone) – of the studied species of animals by the method of comparative anatomy. 5. Determining the morphological features of the bones – internal structure of the skulls and frontal sinuses – of the studies species of animals (red foxes and raccoon dogs) by the method of computer tomography. The present work is a first attempt of comparative morphological analysis of the... [to full text]
3

Kompiuterinės regos taikymų tyrimai medienos kokybės kontrolei / Research of computer vision application for the control of wood quality

Malinauskas, Mindaugas 26 May 2004 (has links)
Wood is a limited natural resource whose characteristics have been difficult to identify by advanced technology. The most expensive is a hardwood. There is a desire to optimize the production of wood products by minimizing waste and maximizing output. It could be achieved if one had capabilities to evaluate the common wood structures ― knots, rots, empty spaces and other defects. There are many nondestructive testing methods that could be applied to the evaluation of the inner quality of a log. The most successful one is an x-ray computerized tomography. This thesis covers principles of computerized tomography and image reconstruction algorithms. Testing was performed on implementations of tomographic image reconstruction algorithms using synthetic and real data. Research on an application of an x-ray computerized tomography for the analysis of wood structures was made. Inspection of glued zones in glued wooden articles was accomplished using tomographic imaging. Guidelines for the creation of a wood specialized x-ray computerized tomograph were given.
4

Ultragarsinio tyrimo ir kompiuterinės tomografijos palyginamoji vertė diagnozuojant pavienius židininius kepenų pakitimus / Comparative value of ultrasonography and computed tomography in the diagnostics of solitary focal hepatic lesions

Žvinienė, Kristina 04 May 2009 (has links)
Židininiai kepenų pakitimai (ŽKP) – vieni dažnesnių patologinių radinių tiriant pacientus dėl įvairių virškinimo ar kitų organizmo sistemų ligų. Įvairių spindulinės diagnostikos metodų dėka nustačius patologinius židinius kepenyse ypač svarbi jų klinikinė diferencinės diagnostikos reikšmė. ŽKP diferencinės diagnostikos esmė yra kiek įmanoma tikslesnis židinio kepenyse kraujotakos nustatymas ir aprašymas. Šios problemos sprendime naujų galimybių įgyja santykinai nauja ir Lietuvoje niekur kitur dar neatliekama UG tyrimo su i/v kontrastavimu metodika, kurios metu gaunami rezultatai lyginami su dominuojančių įprastų KT ir MRT kontrastinių tyrimų rezultatais. Tikslas: nustatyti radiologinių tyrimų vertę diagnozuojant židininius kepenų pakitimus (ŽKP) Uždaviniai: 1. Nustatyti įprastinio UG, UG su i/v kontrastavimu ir KT su i/v kontrastavimu diagnostikos metodų tikslumo rodiklius nepiktybiniams ir piktybiniams ŽKP. 2. Nustatyti UG ir KT su i/v kontrastavimu vertingiausius diagnostikos kriterijus vertinant židininių kepenų pokyčių prigimtį. 3. Palyginti tarpusavyje UG ir KT su i/v kontrastavimu nustatytų židininių kepenų pakitimų diagnostikos metodų tikslumo rodiklius nepiktybiniams ir piktybiniams ŽKP. 4. Įvertinti kepenų hemangiomų radiologinių diagnostikos metodų tikslumo vertę. / Focal hepatic lesions (FHL) are one of the most common pathological findings in patients who are examined for gastrointestinal or other diseases. The rigorous description of blood circulation in the hepatic focus is essential in differential diagnosis of FHL. US with i/v contrast enhancement is a new imaging method enabling definition of nature of FHL, follow-up, treatment efficacy and monitoring for possible relapse of the process. This study is conducted solely in the Radiology Department of Kaunas University of Medicine Hospital. Aim of the study To evaluate and compare the value of ‘bolus’ contrast-enhanced CT and contrast-enhanced US in diagnostics of focal hepatic lesions. Tasks of the study 1. To determine rates of diagnostic accuracy of conventional US, US with i/v contrast enhancement and ‘bolus’ contrast-enhanced CT in diagnosis of benign and malingnant FHL. 2. To establish the main and most effective diagnostic criteria of US and CT with i/v contrast enhancement for the assessment of nature of focal hepatic lesions. 3. To compare rates of diagnostic accuracy of US with i/v contrast enhancement and ‘bolus’ contrast-enhanced CT in diagnosis of benign and malingnant FHL. 4. To assess the reliability of radiological diagnostics of hemangioma, comparing the results of US, CT, and MRI.
5

Kūginio pluošto kompiuterinės tomografijos diagnostinių galimybių endodontijoje tyrimai / Evaluation of diagnostic abilities of cone-beam computed tomography in endodontics

Venskutonis, Tadas 04 September 2014 (has links)
Daktaro disertacijos „Kūginio pluošto kompiuterinės tomografijos diagnostinių galimybių endodontijoje tyrimai” tikslas - įvertinti kūginio pluošto kompiuterinės tomografijos (KPKT) galimybes tiriant viršūninio apydančio būklę ir danties šaknies kanalo gydymo rezultatus klinikinėmis sąlygomis bei ex vivo modelyje. Uždaviniai: 1) palyginti skaitmeninės intraoralinės rentgenografijos (SPR) ir KPKT metodų efektyvumą, diagnozuojant danties šaknies kanalo perforacijas žmogaus apatinio žandikaulio ex vivo modelyje bei nustatyti optimalų tūrinio vaizdo elemento dydį; 2) palyginti dantų šaknų perforacijų vietos ir dydžio įtaką KPKT diagnostinėms savybėms žmogaus apatinio žandikaulio ex vivo modelyje; 3) palyginti dantų šaknų perforacijų diagnozavimą skirtingose KPKT rekonstrukcinėse projekcijose žmogaus apatinio žandikaulio ex vivo modelyje; 4) palyginti SPR ir KPKT metodų tikslumą, vertinant endodontiškai gydytų pacientų dantų šaknų viršūninio apydančio (VA) būklę; 5) Sukurti pacientų VA būklės ir endodontinio gydymo kokybės įvertinimo sistemą (PESS), pagrįstą KPKT metodo tyrimo rezultatais; 6) Pagal kompleksinį viršūninio apydančio būklės įvertinimo indeksą, (COPI) ištirti pacientų VA būklę, naudojant KPKT ir skaitmeninę ortopantomografiją (SOR) bei palyginti abiem metodais gautus rezultatus; 7) Pagal endodontiškai gydytų dantų indeksą (ETTI), įvertinti pacientų endodontinio gydymo kokybę, naudojant KPKT ir SOR bei palyginti abiem metodais gautus rezultatus. / The aim of doctoral dissertation "Evaluation of diagnostic abilities of cone-beam computed tomography in endodontics” are to evaluate the cone-beam computed tomography (CBCT) diagnostic ability in assessment of periapical bone lesions and tooth root canal treatment outcome clinically and in ex vivo model. Objectives: 1) to compare the diagnostic abilities of CBCT and digital periapical radiogram (DPR) methods in the detection of root perforations ex vivo and to assess the use of different voxel sizes of a CBCT unit; 2) to assess the influence of root perforations sizes and locations on diagnostic performance of CBCT ex vivo; 3) to assess the influence of different reconstruction planes of CBCT in diagnosing root perforations ex vivo; 4) to compare the accuracy of DPR and CBCT in the detection of periapical radiolucencies in endodontically treated teeth; 5) to develop new patients Periapical and Endodontic Status Scale (PESS) by means of CBCT analysis; 6) to investigate periapical status of the patient using Complex Periapical Index (COPI) with two radiological methods (CBCT and digital orthopantomogram (DOR)) and to compare their results; 7) to investigate endodontic treatment quality using Endodontically Treated Tooth Index (ETTI) with two radiological methods (CBCT and DOR) and to compare their results.

Page generated in 0.0719 seconds