• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dämpning av pulsationer i kylkretsen / Damping of Pulsations in the Refrigeration Circuit

Jansson, Peter January 2014 (has links)
Värmepumpar ger ifrån sig ljud när dessa kommer upp i temperatur, vilket kan bli ett problem då det kan störa omgivningen. Om man kan sänka ljudnivån blir den mer attraktiv för kunderna.Syftet med examensarbetet är att undersöka om det går att mäta ljudet och vibrationerna som uppstår när komprimerad gas expanderar snabbt i samband med att den lämnar kompressorn.En dämpare som minimerar oljudet samtidigt som den är billig, kostnadseffektiv samt enkelska sedan konstrueras. Dämparna som testades varierade i storlek och form. En av de testade dämpare gav till sist en vibrationsdämpning av värmepumpen och tillverkades sedan. / The heat pump emits noise when the temperature increases, which can be a disturbing factor to the surrounding environment. The heat pump could become more attractive to the costumers if the noise was decreased.The objective with the examination paper is to investigate if the noise and vibrations could be measured that occurs when a compressed gas expands and leaves the compressor rapidly. A cheap, costeffective and simple damper will be constructed.The dampers that were tested had a diversity of shapes and forms, and at last the damper with damping materials gave a decreased vibration.
2

Driftoptimering av kyl- och frysanläggning : En analys av en kaskadprocess med partiell förångning

Holmgren, Robin, Hallenberg, Dante January 2016 (has links)
Studien är utförd åt Freezing Food Småland Öland AB. Syftet med undersökningen var att ge förslag på åtgärder som minskar anläggningens energibehov samt att beräkna återbetalningstid för åtgärder. Genom användningen av simuleringsprogramvara tillsammans med data från praktiska mätningar så testades olika förändringar i anläggningen. Studien resulterade i förslag på en höjning av frysrumstemperaturen och temperaturen i LTB1. Dessa åtgärder höjer anläggningens köldfaktor och minskar energibehovet. Förslag för att få bukt på istillväxten är att isolera av komponenter så som rör och ventiler. Isolering ger en energibesparing och en minskad risk för korrosion. Genom belastningstester framkom det att kompressorerna arbetar ofördelaktigt så förslag på lämpliga driftområden togs fram för att öka verkningsgraden och minska underhållskostnaderna och energibehovet. Anläggningen visade sig vara väl dimensionerad mot transmissionsförluster men att golvvärmen står för en oproportionerligt stor del av förlusterna i förhållande till dess yta. / The study is conducted for Freezing Food Småland Öland AB. The purpose of the study was to propose measures to decrease the facility’s energy demand and to calculate the payback time for these suggestions. By means of using simulation software along with data from practical measurements different configurations in the facility were tested. The study resulted in suggestions consisting of an increase of the temperature in the freezing room and the temperature in LTB1.Those suggestions increases the facilities COP and decreases the energy consumption. Proposals to curb the ice growth are the insulation of components such as pipes and valves. Insulation results in a small decrease in energy demand but greatly increases the accessibility and also decreases the risk of corrosion. Through load tests conducted on the compressors it showed that the compressors were not driven in the optimal load range, suggestions were made for operation in a more favourable load range. Thus increasing the efficiency and cutting the maintenance costs. From the results it is shown that the facility is well built and dimensioned against thermal transmission. Though it turned out that the floor heating accounts for a disproportionate amount of the thermal transmission.
3

Bergkylsystemets påverkan på processen : En utvärdering och energieffektivisering på bergkylsystemet hos More biogas i Läckeby

Oskarsson, Joakim, Olsson, Johan January 2021 (has links)
Arbetet baseras på en kylanläggning som installerats på ett biogas företag, som till en början var tänkt som ett pilotprojekt men som nu används fullt ut i anläggningen. Projektet var inte utvärderat eller dokumenterat och vilken effekt som överförs var obekant. Arbetets innebörd var att beräkna effekten samt dokumentera systemet i form av både beräkningar, ritning och eventuella effektiviserings områden. Beräkning gjordes via entalpi skillnaden som togs ut över involverade värmeväxlare, samt flödet som togs ut via en reglerventil med hjälp av ett mätinstrument. Ritning gjordes via programmet Visio utifrån anläggningens nuvarande konstruktion. Resultatet för kyleffekten som överfördes beräknades fram via flöde och entalpi, med resultatet 14,03kW över båda värmeväxlarna. Även beräkning på vad en potentiell förbättring av isolering i rörsystemet skulle kunna bidra med där utifrån beräkningarna skulle energibesparingen kunna fördubblas gentemot nuvarande. / The work is based on a cooling plant installed at a biogas company, which was initially intended as a pilot project but is now fully used in the plant. It is not evaluated or documented and how much power is transmitted is unknown. The meaning of the work is to find out the effect and document the system in the form of both calculations, drawing and any areas of efficiency. Calculation was made via enthalpy the difference that was taken out over the heat exchangers involved, as well as the flow that was taken out via a control valve with the help of a measuring instrument. Drawing was made via the Visio program based on the facility's current design. The result for the cooling power that was transferred was calculated via flow and enthalpy, where the result was 14.03 kW over both heat exchangers. Calculation of what a potential improvement of insulation of the pipe system could contribute, based on the calculations, the energy savings could be doubled compared to the current one.

Page generated in 0.0361 seconds