• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 83
  • 11
  • 9
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 114
  • 63
  • 24
  • 17
  • 14
  • 14
  • 11
  • 10
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Simula??o do escoamento multif?sico no interior de bombas de cavidades progressivas met?licas

Azevedo, Victor Wagner Freire de 05 November 2012 (has links)
Made available in DSpace on 2014-12-17T14:58:16Z (GMT). No. of bitstreams: 1 VictorWFA_DISSERT.pdf: 4406666 bytes, checksum: 17531cab6caf785a3e82578d15d0e5d9 (MD5) Previous issue date: 2012-11-05 / The progressing cavity pumping (PCP) is one of the most applied oil lift methods nowadays in oil extraction due to its ability to pump heavy and high gas fraction flows. The computational modeling of PCPs appears as a tool to help experiments with the pump and therefore, obtain precisely the pump operational variables, contributing to pump s project and field operation otimization in the respectively situation. A computational model for multiphase flow inside a metallic stator PCP which consider the relative motion between rotor and stator was developed in the present work. In such model, the gas-liquid bubbly flow pattern was considered, which is a very common situation in practice. The Eulerian-Eulerian approach, considering the homogeneous and inhomogeneous models, was employed and gas was treated taking into account an ideal gas state. The effects of the different gas volume fractions in pump volumetric eficiency, pressure distribution, power, slippage flow rate and volumetric flow rate were analyzed. The results shown that the developed model is capable of reproducing pump dynamic behaviour under the multiphase flow conditions early performed in experimental works / O bombeio por cavidades progressivas (BCP) ? um dos m?todos de eleva??o artificial mais utilizados atualmente pela ind?stria do petr?leo devido ? sua capacidade de atuar em reservat?rios de ?leos pesados e com elevada fra??o de g?s. A modelagem computacional de BCPs surge como uma ferramenta para auxiliar os experimentos com a bomba e assim obter com precis?o as suas vari?veis de opera??o, o que contribui para a otimiza??o do projeto e da opera??o da bomba na situa??o a qual se encontra. Um modelo computacional do escoamento multif?sico no interior de uma BCP de estator met?lico que considera o movimento relativo entre o rotor e o estator foi desenvolvido no presente trabalho. Em tal modelo, o escoamento g?s-l?quido no padr?o de bolhas foi considerado, o que ? uma situa??o muito comum na pr?tica. A abordagem Euleriana- Euleriana, considerando o modelo homog?neo e n?o-homog?neo, foi empregada e o g?s foi tratado levando em considera??o um estado de gas ideal. Os efeitos das diferentes fra??es de g?s na efici?ncia da bomba, distribui??o de press?o, pot?ncia, taxa de escorregamento e vaz?o volum?trica foram analisados. Os resultados mostraram que o modelo desenvolvido ? capaz de reproduzir o comportamento din?mico da BCP sob as condi??es de escoamento multif?sico previamente realizados em trabalhos experimentais
82

Repotenciação de usinas hidrelétricas utilizando perfil alternativo de máquinas hidráulicas

Rondina, José Mateus 13 December 2016 (has links)
A geração de energia limpa e sustentável ocupa, cada vez mais, lugar de destaque nas preocupações da humanidade. A otimização da utilização dos recursos naturais para essa finalidade, assim como para produção de alimentos, consumo de água, transportes e outras necessidades, torna-se a cada dia um desafio maior. Assim, a geração de energia elétrica, tendo como matriz os recursos hidrícos, ainda principal matriz energética instalada no Brasil, encontra-se no seu limiar de disponibilidade no que se refere a aproveitamentos por grandes plantas geradoras. A instalação de micro e miniprojetos de geração de energia encontrou, em recente legislação do setor elétrico nacional, a possibilidade de conexão de seus geradores ao sistema de distribuição através da Geração Distribuída, pela modalidade de compensação de energia consumida e gerada. Tal possibilidade inaugura uma nova realidade para a geração de energia hidrelétrica a medida em que viabiliza a implantação de projetos para mananciais de pequena expressão, que até então estavam relegados a geração em sistemas isolados. Se por um lado a legislação derrubou um histórico impedimento a esses projetos, por outro lançou o desafio de torna-los viáveis. A compensação de quantidades consumidas de energia elétrica por energia gerada e entregue a rede de distribuição, com a realidade de isenção de impostos em vigor, por si é uma alavanca no sentido dessa viabilidade. Não obstante não é suficiente. Barreiras tais como a complexidade técnica e operacional, aliada aos elevados preços de aquisição, operação e manutenção das máquinas geradoras de energia hidrelétrica disponíveis no mercado ainda são muito impeditivas. Nesse sentido esse trabalho traz uma proposta de alternativa técnica para colaborar na viabilidade da implantação de pequenos projetos de geração de energia hidrelétrica, bem como na repotenciação de plantas antigas, depreciadas e geralmente ineficientes, inúmeras delas abandonadas pelo país. Trata-se da proposta de utilização de um perfil alternativo para turbinas hidráulicas, a máquina geradora de fluxo em lugar das turbinas. O trabalho relata a experiência na repotenciação de uma antiga central hidrelétrica de 600 kW, repotenciada para 3.000 kW, pela substituição de seus equipamentos por máquinas hidráulicas geradoras de fluxo (bombas) acionando geradores síncronos, com unidades de 500 kW. / The generation of clean and sustainable energy is increasingly prominent in the concerns of humanity. The optmization of the use of natural resources for this purpose, as well as for food production, water consumption, transport and other necessities is becoming a major challenge. Therefore, a generation of electric power, with hydropower resources, main source of energy installed in Brazil, is at its availability limit without reference to large power plants. The installation of micro and mini power generation projects has found, in the national electricity sector recent legislation, the possibility of connecting their generators to the distribution system through Distributed Generation, through the compensation modality of consumed and generated energy. This possibility inaugurates is a new reality for the generation of hydroelectric power as it allows the implementation of projects for small-scale water sources, which until then were relegated to generation in isolated systems. On the one hand legislation has overthrown a historic impediment to such projects, on the other it has launched the challenge of making them viable. The quantities compensation of electricity consumed by energy generated and delivered to the distribution network, with the reality of tax exemption in force, in itself is a lever in the direction of this viability. Nevertheless it is not enough. Barriers such as technical and operational complexity, allied with the high prices of acquisition, operation and maintenance of the hydroelectric generating machines available in the market are still very preventable. In this sense, this work proposes a technical alternative to collaborate in the viability of the implantation of small hydropower generation projects, as well as in the repowering of old, depreciated and generally inefficient plants, many of them abandoned across the country. This is about the proposal to use an alternative profile for hydraulic turbines, the flow generating machine instead of the turbines. The work reports the experience of repowering a former 600 kW hydroelectric plant, repowered to 3,000 kW, by replacing its equipment with flow-generating hydraulic machines (pumps) powering synchronous generators with 500 kW units. / Tese (Doutorado)
83

Následky výbuchu špinavé bomby / Burst effects of radiation dispersal weapon

SADÍLKOVÁ, Alexandra January 2008 (has links)
One of the relatively cheap and easily available instruments suitable for a terrorist attack is the dirty bomb. Using conventional charges (TNT, Semtex etc.) it disperses radioactive materials. Its use is based on contamination of the area where the explosion took place and on creating a radioactive cloud, which may travel rather fast depending on the wind, and which pollutes other areas with its fall-out particles. Such areas become dangerous to live or stay in for a longer period due to the danger of irradiation sickness and cancer. The polluted areas must be decontaminated, which is a very difficult task. Another problem that may occur after the explosion of such a bomb is also panic as well as burns and injuries caused by shells. This work deals with possibilities of radiological weapon construction, the results of using a dirty bomb and with the work of integrated emergency services on such an occasion.
84

Desgaste e corrosão de bombas de combustível com misturas de álcool e gasohol. / Wear and corrosion of fuel pumps with alcohol and gasohol fuel blends.

Fernando Fusco Rovai 04 March 2005 (has links)
O presente trabalho avalia o impacto da utilização de misturas de álcool e gasohol no desgaste e corrosão de bombas elétricas de combustível. / Assessement of alcohol and gasohol fuel blends impact on wear and corrosion of electric fuel pumps.
85

Simulação computacional de bombas com velocidade de rotação variável no EPANET / Computer simulation of variable speed pumps in EPANET

Coutinho, Ricardo Santos 10 December 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-01-29T17:14:46Z No. of bitstreams: 2 Dissertação - Ricardo Santos Coutinho - 2015.pdf: 10137543 bytes, checksum: 50b06893fd31466aedf36ff57ca15495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-01T11:58:11Z (GMT) No. of bitstreams: 2 Dissertação - Ricardo Santos Coutinho - 2015.pdf: 10137543 bytes, checksum: 50b06893fd31466aedf36ff57ca15495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-02-01T11:58:11Z (GMT). No. of bitstreams: 2 Dissertação - Ricardo Santos Coutinho - 2015.pdf: 10137543 bytes, checksum: 50b06893fd31466aedf36ff57ca15495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-12-10 / In water distribution systems, most of the electricity is consumed by pumping systems. Thus, reducing the inefficiency of the pump can provide significant energy savings. This can be achieved by substituting fixed-speed pumps by variable-speed pumps (VSP). However, the high costs of installation and operation of the VSPs require a preliminary economic assessment of the design, which is usually accompanied by the use of hydraulic solvers to simulate the behavior of the water network. One of the most used softwares for this purpose is the EPANET 2, which uses the gradient method for the hydraulic analysis of the steady flow. However, the EPANET 2 is inaccurate when computing the VSP efficiency. This is because the software does not take into account the changes in the pump efficiency curve when the pump speed is changed. In this study, a routine for calculating VSPs efficiency, based on the Sârbu and Borza (1998) formula, is implemented in the source code of the EPANET 2. The influence of the new routine on the results predicted by the software for efficiency, power and energy consumption of the VSP is evaluated in simulations with a hypothetical network. The results showed that the original version of EPANET 2 tends to underestimate the efficiency and thus overestimate the power and energy consumption of the VSPs. In the present case, the energy consumption of the system predicted by the original version of EPANET 2 was 21.99% higher than the predicted by the modified version. These results point out that the modified version of EPANET 2 provides a better prediction of VSPs behavior and thus its use is recommended in the simulation of water distribution networks equipped with VSPs. / Em redes de distribuição de água, a maior parte da energia elétrica é consumida pelos sistemas de bombeamento. Deste modo, a redução da ineficiência das bombas pode proporcionar uma economia expressiva de energia. Isto pode ser alcançado pela substituição de bombas de rotação constante por bombas de rotação variável (BRVs). No entanto, os elevados custos de instalação e operação de BRVs requerem uma avaliação econômica prévia do projeto, a qual geralmente é acompanhada do uso de simuladores hidráulicos para simular o comportamento da rede. Um dos programas mais utilizados para este fim é o EPANET 2, o qual emprega o Método Gradiente para a análise hidráulica do escoamento permanente. Todavia, o EPANET 2 é impreciso ao computar a eficiência de BRVs. Isto ocorre porque o programa não leva em conta a mudança na curva de eficiência da bomba quando sua velocidade de rotação é alterada. No presente trabalho, uma rotina para o cálculo da eficiência de BRVs, baseada na fórmula de Sârbu e Borza (1998), é implementada no código-fonte do EPANET 2. A influência da nova rotina nos resultados previstos pelo programa para a eficiência, potência e consumo de energia de BRVs é avaliada em simulações com uma rede hipotética. Os resultados mostraram que a versão original do EPANET 2 tende a subestimar a eficiência e, consequentemente, superestimar a potência e o consumo de energia de BRVs. No caso em tela, o consumo de energia do sistema previsto pela versão original do EPANET 2 foi 21,99% maior que o previsto pela versão modificada. Tais resultados apontam que a versão modificada do EPANET 2 proporciona uma melhor previsão do comportamento de BRVs e, portanto, o seu uso é recomendado na simulação de redes de distribuição de água equipadas com BRVs.
86

Elaboração do passado e indústria cultural: possibilidades de esclarecimento a respeito dos bombardeios às cidades de Hiroshima e Nagasaki / Working through the past and cultural industry: enlightenment possibilities about the atomic bombing of Hiroshima and Nagasaki

Artur Rafael Agostinho Theodoro 29 May 2015 (has links)
Esta pesquisa tem como objetivo analisar o potencial de esclarecimento de dois conjuntos de materiais. O primeiro consiste em uma exposição a respeito do ataque nuclear às cidades de Hiroshima e Nagasaki. Essa exposição é composta por 30 painéis contendo desenhos, fotografias, textos e gráficos. O segundo conjunto de materiais consiste em matérias jornalísticas recentemente publicadas pela mídia impressa a respeito da bomba atômica. Tais matérias, por sua vez, utilizam-se de textos, fotografias e gráficos. A partir de contribuição de autores vinculados à Teoria Crítica da Sociedade, em especial Theodor W. Adorno, Max Horkheimer e Herbert Marcuse, os materiais são analisados levando-se em conta as noções de elaboração do passado, racionalidade técnica e indústria cultural. Embora recorram à utilização de elementos semelhantes, procura-se demonstrar que os dois conjuntos de materiais acabam por diferir entre si quanto aos seus limites ou, em outras palavras, quanto ao seu potencial de esclarecimento. Isto porque a influência que recebem da indústria cultural, materializada pela presença de elementos característicos desta última no material analisado, nos parece diversa, preponderando em relação às produções da mídia impressa / This research has the purpose of analyzing the potential of enlightenment in two groups of materials. The first one consists in an exposition about the nuclear attack to the cities of Hiroshima and Nagasaki, composed by thirty panels with drawings, photographs, texts and graphics. The second group of materials consists in newspapers news recently published by the printed media referring to the atomic bomb. These news, in its turn, uses texts, photographs and graphics. From the contribution of the authors from Frankfurt School, in special Theodor W. Adorno, Max Horkheimer and Herbert Marcuse, the materials are analyzed taking into account the notions of working through the past, technical rationality and cultural industry. Although they resort to the utilization of similar elements, we try to demonstrate that the two groups of materials turn out to differ among themselves as to their limits or, in other words, as to their potential of enlightenment. This is explained by the diverse influence that they receive from the cultural industry, materialized by the presence of characteristic elements of the later in the analyzed material, which seems to us more prevalent in relation to the printed media productions
87

Aderência ao tratamento com inibidores da bomba protônica em pacientes com doença do refluxo gastroesofágico / Adherence to the treatment with proton pump inhibitors in patients with gastroesophageal reflux disease

Karine Dal Paz 25 August 2010 (has links)
Introdução: A Doença do Refluxo Gastroesofágico (DRGE) possui elevada prevalência e morbidade. O tratamento clínico consiste em recomendações quanto ao estilo de vida e, essencialmente, no uso de inibidores da bomba protônica (IBP). A aderência (Ad) dos pacientes com DRGE à prescrição, embora fundamental para o sucesso terapêutico, tem sido pouco estudada. Objetivo: Avaliar a Ad ao tratamento com IBP e possíveis variáveis relacionadas em pacientes com DRGE. Métodos: Estudo transversal e prospectivo com 240 pacientes adultos consecutivos com DRGE erosiva e não-erosiva (ne-DRGE) que haviam recebido dose padrão ou dose dobrada de omeprazol em uso contínuo. Todos os pacientes foram classificados conforme o grau, segundo os achados da endoscopia digestiva alta (EDA) em ne-DRGE (162; 67,5%), classificação endoscópica de Los Angeles (LA) A (48; 20,0%), LA B (21; 8,6%), LA C (1; 0,4%), LA D (1; 0,4%) e Barrett (7; 2,9%). Foi aplicado o questionário de Morisky et al constituído de 4 questões com respostas dicotômicas para avaliar a Ad, classificando-a como baixa (0-2 pontos) e alta ad (3-4 pontos). Foi também aplicado o questionário QS-DRGE para a avaliação dos sintomas, com 10 questões com escores de 0 a 50, conforme a frequência menor ou maior dos sintomas. Os resultados de Ad foram relacionados com os dados sócio-demográficos, polifarmácia (PF) (uso de mais de cinco medicamentos diariamente), comorbidades (CM), tempo de tratamento (TT), escore QS-DRGE, presença de sintomas descrita em prontuário, achados da EDA e conhecimento do paciente sobre a doença. Resultados: (1) 126 pacientes (52,5%) apresentaram alta Ad e 114 (47,5%) baixa Ad; (2) Os pacientes mais jovens (p = 0,002) foram menos aderentes; (3) Pacientes sintomáticos de acordo com relato em prontuário apresentaram maior percentual de baixa Ad e 2 vezes maior probabilidade de ter baixa Ad em relação aos assintomáticos (p = 0,02); (4) Os pacientes casados apresentam probabilidade 2,41 vezes maior de ter baixa Ad do que os viúvos. (5) As demais variáveis estudadas não influenciaram a Ad ao tratamento. Conclusões: Pacientes em uso de IBP em tratamento ambulatorial em hospital terciário em São Paulo apresentaram grande percentual de baixa Ad ao tratamento, sendo esta uma possível causa da falha da terapia com IBP. Idade < 60 anos e estado civil casado podem ser fatores de risco para a baixa Ad / Introduction: The Gastroesophageal Reflux Disease (GERD) is a highly prevalent disease and a major cause of morbidity. Clinical treatment is based on lifestyle recommendations and, essentially, in the use of a proton pump inhibitor (PPI). Adherence (Ad) of GERD patients to the prescribed treatment, although critical for therapeutic success, has been little studied. Objective: Assess adherence to the PPI treatment and potential associated variables in patients with GERD. Case studies and Methods: Transversal and prospective study with 240 consecutive adult patients, diagnosed with erosive GERD (e-GERD) and non-erosive GERD (ne-GERD) for whom continuous use of the standard dose or the double dose of omeprazol had been prescribed. Patients were ranked according to the findings of high digestive endoscopy (HDE) in ne-GERD (162; 67.5%); e-GERD: Los Angeles (LA) endoscopic classification A (48; 20.0%), LA B (21; 8.6%), LA C (1; 0.5%), and LA D (1; 0.5%) and Barretts esophagus (7; 2.9%). The Morisky questionnaire, that includes four questions with dicotomic responses to assess Ad, was applied. Ad was classified as low (0-2 points) and high (3-4 points). In addition, the QS-GERD questionnaire was applied to assess symptoms, using 10 questions with score 0 to 50, according to the greater or lesser symptom frequency. Ad results were correlated with personal data (gender and age), demography, polypharmacy (PF), comorbidities (CM), treatment time (TT), QS-GERD scores, symptoms described in the patients record, HDE findings and patient awareness about the disease. Results: (1) 126 patients (52.5%) exhibited high Ad and 114 (47.5%) low Ad; (2) younger patients (p = 0,002) were less compliant; (3) married patients had a 2.41 greater probability to exhibit low Ad as compared to widowers (p = 0.03); (4) patients with symptoms indicated in the patients record exhibited a lower Ad rate and twice greater probability of exhibiting low Ad as compared to asymptomatic patients (p = 0.02); (5) the other variables studied had no influence on treatment adherence. Conclusion: Patients using PPI as out-patients in third care hospital in São Paulo exhibited high rate of reduced treatment adherence, and this may be a potential cause of PPI therapy failure. Age < 60 years and marital status may be risk factors for low adherence
88

Avaliação do desempenho de bomba multifásica na geração de microbolhas de ar para o processo de flotação por ar dissolvido aplicado ao pré-tratamento de efluente de indústria têxtil / Evaluation of performance of multiphase pump in the air microbubble generation for dissolved air flotation process applied to pre-treatment of textile wastewater

André Pioltine 25 March 2009 (has links)
A flotação por ar dissolvido (FAD) é um método de separação de fases bastante utilizado em sistemas de tratamento de efluentes industriais. Nos últimos 20 anos, numerosos avanços têm contribuído para uma maior eficiência deste processo. Entre estes, podem-se citar os avanços nos métodos para a saturação de ar na água. Atualmente tem-se realizado estudos com a utilização de bombas multifásicas em substituição às unidades de saturação tradicionais, com vistas a se buscar maior simplicidade e facilidade operacional, aliados à menor necessidade de manutenção periódica da unidade de saturação. Desta forma, o presente trabalho teve como objetivo avaliar o desempenho de uma bomba multifásica na geração de microbolhas de ar no processo de flotação por ar dissolvido para o tratamento de efluente de indústria têxtil. O projeto foi dividido nas seguintes etapas: Etapa I - com o emprego do Flotateste, foram determinadas as dosagens adequadas de coagulante e polímero para o tratamento do despejo líquido industrial em estudo; Etapa II - utilizando-se uma unidade piloto de flotação por ar dissolvido montada nas instalações de uma indústria têxtil, avaliou-se a influência das condições de operação (taxa de aplicação superficial, razão de recirculação, pressão de saturação e quantidade de ar fornecida) na eficiência do sistema constituído pela bomba multifásica. Considerando a taxa de aplicação superficial empregada neste estudo, a qual foi mantida em faixa estreita de valor (TASclar em torno de 128,6 ± 10 m/d), verificou-se que os maiores valores de eficiência de remoção dos parâmetros monitorados foram obtidos nos ensaios realizados com razão de recirculação igual a 30% associados ao fornecimento de ar de 13%. Nos ensaios onde se realizou a avaliação da concentração de ar presente na recirculação pressurizada, as concentrações de ar efetivamente fornecidas (fração dissolvida e não dissolvida) pelo sistema constituído pela bomba multifásica, foram superiores às concentrações máximas teóricas de ar dissolvido calculadas a partir da Lei de Henry. O valor da relação A/S que forneceu os melhores resultados situou-se em torno de 0,015 g ar/g sólidos. Desta forma, sugere-se tal valor como subsídio ao projeto de sistema de flotação constituído pela tecnologia em estudo nesta pesquisa. / The dissolved air flotation is a method for solid/liquid separation that is used in the industries to treat the wastewater. In the last 20 years, several advances have been added to increase the process\' efficiency. For example, there are the advances in the air saturation methods. Nowadays, studies have been carried out with the use of multiphase pumps instead of conventional saturator units. This way, the aim of this research was to evaluate the performance of a multiphase pump in the air microbubble generation for dissolved air flotation process that is applied to treat the effluent of textile industry. The research was performed in two stages: i) on laboratory scale (Flotatest), where the adequate dosages of coagulant and flocculation aid were carried out; ii) in a pilot unit, where studies were conducted aiming at the evaluation of operational conditions in the system\'s efficiency. In the pilot unit (hydraulic surface loading equal to 128,6 ± 10m/d) , it was verified that the best results in terms of removal efficiency of monitored parameters were obtained for the essays performed with recirculation ratio equal to 30%, air supply of 13% and A/S ratio equal to 0.015 g air/g solids. The air concentrations supplied (dissolved fraction and non-dissolved fraction) by the system were higher than the maximum theoretical concentration of dissolved air (Henry\'s law).
89

Identificação da vazão de gás de uma bomba centrífuga em regime de escoamento multifásico através de dados experimentais : Identification of the gas flow of an electric submersible pump under multiphase flow thou experimental data / Identification of the gas flow of an electric submersible pump under multiphase flow thou experimental data

Martinez Ricardo, Diana Marcela, 1986- 24 August 2018 (has links)
Orientador: Janito Vaqueiro Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-24T20:08:14Z (GMT). No. of bitstreams: 1 MartinezRicardo_DianaMarcela_M.pdf: 3485991 bytes, checksum: 9bd64ce80b2e1c25ed98644d4f52fd64 (MD5) Previous issue date: 2014 / Resumo: Este trabalho tem como objetivo desenvolver um processo de identificação da vazão de gás em um dos equipamentos usados na indústria petrolífera, às bombas centrífugas submersas (BCS) em regime de escoamento multifásico. Estas bombas apresentam falhas frequentes prematuras quando a vazão de gás é alta, as quais ocorrem por falta de informação do tipo de escoamento bifásico presente na bomba no tempo de operação. Por isto estudos de identificação experimental são requeridos nesta área. Neste contexto a presente pesquisa tem seu foco na obtenção de modelos mediante dados experimentais, recompilados diretamente da resposta do sistema que descrevem o comportamento da vazão de gás na planta de interesse, como: vibração, vazão, elevação entre outros. Estes modelos estão baseados na identificação não paramétrica e no algoritmo de aprendizagem de Máquina de Vetores de Suporte (SVM), onde os parâmetros ocultos da máquina de aprendizagem serão obtidos mediante algoritmos genéticos, visando obter modelos mais representativos / Abstract: This work develops a process to identify the flow of gas in one of the equipment used in the oil industry, the electric submersible pump (EPS) under multiphase flow. These pumps feature frequent premature failures when the gas flow is high. That occurs due to lack of information on the type of two ¿ phase flow in the pump in operation time. Experimental studies for this identification are required in this area. In this context, the present research focuses on obtaining models by experimental data collected directly from the system response which describes the behavior of the gas flow on the system of interest such as: vibration, fluid, elevation etc. These models are based on nonparametric identification and in learning algorithm support vector machine (SVM), where the hidden parameters of the learning machine will be obtained by genetic algorithms in order to obtain more representative models / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestra em Engenharia Mecânica
90

Métodos de diagnóstico de falhas aplicados à identificação de parâmetros do escoamento do bombeio centrífugo submerso / Time series fault detection and identification methods applied to ESP flow parameters identification

Foresti, Bernardo Pereira, 1983- 09 January 2014 (has links)
Orientador: Janito Vaqueiro Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-26T00:41:26Z (GMT). No. of bitstreams: 1 Foresti_BernardoPereira_M.pdf: 7267999 bytes, checksum: 1a200bffc0e39d2a529a64080b7ddad0 (MD5) Previous issue date: 2014 / Resumo: Neste trabalho buscou-se desenvolver uma metodologia que se valendo de dados de vibração estrutural de carcaça e da operação de uma bomba do bombeio centrífugo submerso (BCS) fosse capaz de identificar parâmetros da operação deste tipo de máquina, tais como: vazão mássica de líquido e gás, diferença de pressão, eficiência e potência mecânica. Para isso foram adaptados os seguintes métodos de diagnóstico de falhas: Método Baseado na Densidade Espectral de Potência, Método Baseado na Função Resposta em Frequência, Método Baseado na Medida de Coerência, Métodos Baseados nos Parâmetros do Modelo (Geométrico e Não-geométrico), Métodos Baseados nos Resíduos do Modelo (Baseado na Variância e Auto-covariância dos Resíduos) e Método Baseado em Modelos Funcionais. Tais métodos requerem a organização de um banco de dados, na fase de levantamento de referências utilizado para comparação com dados obtidos na fase de inspeção, visando à detecção, identificação e estimação da magnitude das falhas e defeitos, conceitos adaptados para o problema apresentado neste trabalho. A metodologia foi aplicada a dois casos: o primeiro, numérico, baseado em dados obtidos da simulação de um sistema de três graus de liberdade foi utilizado para operacionalização da metodologia e antecipação de problemas e dificuldades em sua aplicação. O segundo, experimental, principal foco deste trabalho, baseado em uma bomba utilizada no bombeio centrífugo submerso. Para aplicação da metodologia ao caso experimental, foi elaborado experimento utilizando uma bomba do BCS de quatro estágios instrumentada operando com escoamento bifásico ar-água em diferentes proporções. Resultados indicaram bom desempenho na detecção do tipo de escoamento (monofásico/bifásico), na identificação da vazão mássica de gás escoado e na estimação da vazão de líquido transportado pelo BCS / Abstract: In this research a method using structural vibration and operational data of a pump module normally used with and electrical submersible pump (ESP) has been developed to identify operational parameters, such as: liquid and gas flow rate, differential pressure, efficiency and shaft power. To this end, the following time-series fault detection and identification (FDI) methods were adapted: Power Spectral Density-based Method, Frequency Response Function-based Method, Coherence Measure-based Method, Parameter-based Method (Geometric and Non-geometric), Residual-based Methods (Residual Variance and Residual Uncorrelatedness) and Functional Model-based Method. For FDI, the methods require the set-up of a data base, in the baseline phase used for comparison with data obtained during inspection. The methodology was applied for two cases: A numerical problem based on a three degrees of freedom system, aiming at making functional the programs used and anticipating problematic issues and experimental data from a real ESP pump module, main focus of this work. The experiment consists of measuring structural vibration, and operational data of an ESP pump while varying liquid and gas flow rates keeping shaft speed and suction pressure constant. Results have indicated successful detection of flow type (monophasic/biphasic), identification of the gas flow and estimation of the liquid flow pumped by the ESP pump / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica

Page generated in 0.0563 seconds