• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 75
  • 1
  • Tagged with
  • 76
  • 76
  • 48
  • 33
  • 22
  • 18
  • 17
  • 15
  • 14
  • 13
  • 13
  • 12
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Índice de concordância e risco fuzzy na avaliação do desempenho de sistemas de lagoas de estabilização / Agreement index and fuzzy risk for the evaluation of waste stabilization pond systems

Silva, Fernando José Araújo da 18 October 2010 (has links)
SILVA, F. J. A. Índice de concordância e risco fuzzy na avaliação do desempenho de sistemas de lagoas de estabilização. 2010. 161 f. Tese (Doutorado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2010. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-04T19:37:19Z No. of bitstreams: 1 2010_tese_fjasilva.pdf: 9029880 bytes, checksum: 570f538eedef973cc9ff09a4de221955 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-17T17:32:46Z (GMT) No. of bitstreams: 1 2010_tese_fjasilva.pdf: 9029880 bytes, checksum: 570f538eedef973cc9ff09a4de221955 (MD5) / Made available in DSpace on 2016-05-17T17:32:46Z (GMT). No. of bitstreams: 1 2010_tese_fjasilva.pdf: 9029880 bytes, checksum: 570f538eedef973cc9ff09a4de221955 (MD5) Previous issue date: 2010-10-18 / In the present study fuzzy arithmetic via triangular fuzzy numbers (TFNs) was applied to compute Fuzzy Agreement Index (FAI) and Fuzzy Risk (FR) for the evaluation of operational aspects, performance and effluent quality in 14 full-scale waste stabilization pond plants (6 primary facultative ponds – PFPs and 8 pond series- PSs) treating domestic sewage. Findings showed that fuzzy logic is an attractive approach for the evaluation of the performance of wastewater treatment plants and their environmental compatibilities. The study also provided a better understanding of operational aspects of waste stabilization ponds. Except for two pond systems (PFP4 and PS8) the FAI in PFPs and PSs showed that they operated on average 81.3 and 86.3% of the time below the value stipulated in their original designs. Results indicated average potential increments of 74.7 and 84.5% in influent flow rates to PFPs and PSs, respectively. With respect to organic load () FAI numbers indicated possible increases of 91.8 and 71.9% in PSs and PFPs respectively. In the case of the regulatory standards the FAI applied to effluent quality had best results for DO (PSs = 0.945 and PFPs = 0.867). In general pond series had higher numbers for FAI than PFPs. The fuzzy risk regarded to overloading (organic and hydraulic) was higher in pond series. Comparatively, systems PFP4 and PS8 showed higher fuzzy risk of overloading because these plants operated close to the design numbers. The FR on performance analysis showed that all ponds plants had actual performance slightly below that expected and reported by the literature. The lowest FR values were observed in pond series. On the performance analysis the highest fuzzy risk numbers were for TSS (0.929 in PFPs and 0.903 in PSs), followed by unfiltered COD (0.846 in PFPs and 0.677 in PSs). As expected, fuzzy risk regarded to the violation of environmental standards was higher in PFPs. In pond series by increasing number of cells FR was lower. Positive linear correlations (at a significance level of 95%) showed that lower content of BOD and COD (unfiltered samples), and TSS implied in lower FR with respect to termotolerant coliform concentrations (TTFC). Correlations between FR of pH and TTFC were negative. A Fuzzy Performance Index (FPI) was proposed to compare effluent quality with respect to the environmental standard regulation. The model considered a scale (1-18) based on the following parameters: BODf, CODf, TSS, TAN, DO and TTFC. The results showed the following order: FPI PFP3 (2.09) < FPI PFP2 (2.15) < FPI PFP4 (2.30) < FPI PFP5 (3.49) < FPI PFP1 (3.62) < FPI PFP6 (4.96) < FPI PS5 (9.59) < FPI PS8 (9.67) < FPI PS4 (9.72) < FPI PS3 (10.01) < FPI PS1 (10.38) < FPI PS2 (13. 57) < FPI PS6 (15.49) < FPI PS7 (15.69). The analysis of FR for helminth eggs showed that for a marginal fuzzy risk of 10% pond systems would require a HRT of 28.8 days for oH ≤ 1.0 egg/L, and 38.0 days for oH ≤ 0.1 egg/L. In two series (LS5 and LS8) the FAI and FR with respect to effluent quality from each pond component provided distinctions imposed by the configuration and operational status in each of these plants. Along pond cells in these series BOD and TAN surface removal rates (r) were represent by TFNs. These fuzzy numbers showed negative surface removal rates. They offered an anomalous interpretation for pollutant generation via physical or biotic means. The probable and reasonable cause was the asynchrony between affluent and effluent concentrations, associated with fluctuations in flow rates. Climatic factors and hydraulic behavior of ponds might also influence this. / No presente trabalho foi empregada a aritmética fuzzy com NFTs para o cálculo do Índice de Concordância Fuzzy (ICF) e do Risco Fuzzy (RF), com fins de análise de aspectos operacionais, desempenho e qualidade dos efluentes de 14 ETEs do tipo lagoas de estabilização (6 lagoas facultativas primárias - LFPs e 8 séries- LSs) em escala real, tratando esgotos domésticos. A lógica fuzzy provou ser um recurso eficiente na avaliação do desempenho de ETEs e suas compatibilidades ambientais. O estudo propiciou também uma melhor compreensão do funcionamento operacional de lagoas de estabilização. Exceto por dois sistemas (LFP4 e a LS8) o ICF mostrou que as LFPs e LSs operaram em média 81,3 e 86,3% do tempo, abaixo do valor estipulado em projeto. Nestas seriam possíveis incrementos médios de vazão de 74,7 e 84,5%, respectivamente. Quanto às cargas orgânicas afluentes () os valores de ICF mostraram a possibilidade de acréscimos de 91,8 e 71,9%, para as LSs e LFPs, respectivamente. Sobre a qualidade dos efluentes, o OD obteve os maiores valores de ICF (LSs = 0,945 e LFPs = 0,867). Os valores de ICF para qualidade do efluente tratado foram mais elevados nas séries, com maior concordância fuzzy com as normas ambientais. O risco fuzzy concernente à sobrecarga (orgânica e hidráulica) foi maior nas séries. Individualmente, os sistemas LFP4 e LS8 apresentaram maior risco difuso de sobrecarga, por operarem sob condições próximas às estabelecidas em projeto. O RF para análise de desempenho mostrou que as ETEs tiveram perfomance um pouco abaixo do que observa a literatura técnica. Os menores valores de RF foram observados nos sistemas em série. O risco difuso para não atendimento das expectativas de desempenho foi maior em relação a SST (0,929 nas LFPs e 0,903 nas LSs), seguido de amostras não filtradas de DQO (0,846 nas LFPs e 0,677 nas LSs). Na violação das normas ambientais o RF também foi maior nas LFPs. Observou-se que nas séries, quanto maior o número de lagoas menor o RF. Correlações lineares positivas (nível de significância de 95%) mostraram que quanto menor o conteúdo de DBO e DQO (amostras não filtradas), e de SST, menor o risco difuso em relação a CTm. No caso do RF para pH e CTm a correlação foi negativa. Foi estabelecido um Índice de Desempenho Fuzzy (IFD) para lagoas de estabilização, para comparar a qualidade dos efluentes das ETEs. O modelo propôs uma escala (1 a 18) baseada nos parâmetros DBOf, DQOf, SST, AMT, OD e CTm. Os resultados apresentaram o seguinte ordenamento: IFD LFP3 (2,09) < IFD LFP2 (2,15) < IFD LFP4 (2,30) < IFD LFP5 (3,49) < IFD LFP1 (3,62) < IFD LFP6 (4,96) < IFD LS5 (9,59) < IFD LS8 (9,67) < IFD LS4 (9,72) < IFD LS3 (10,01) < IFD LS1 (10,38) < IFD LS2 (13,57) < IFD LS6 (15,49) < IFD LS7 (15,69). A análise do RF para ovos de helmintos mostrou que para uma margem e risco difuso de até 10% seria necessário um TDH de 28,8 dias com oH ≤ 1,0 ovo/L e 38,0 dias com oH ≤ 0,1 ovo/L. Em duas séries (LS5 e LS8) o cálculo de ICF e RF em relação à qualidade do efluente de cada lagoa componente permitiu observar distinções impostas pela configuração e condição operacional de cada uma dessas ETEs. Nas citadas séries os NFTs foram empregados para avaliar r de DBO e AMT. As representações mostraram taxas de remoção superficial com valores negativos, que ofereceram uma interpretação anômala de geração de poluente por via física ou biótica. A causa foi a assincronia entre as concentrações afluentes e efluentes, associadas à flutuações nas vazões, e, de forma indireta, a fatores climáticos e hidráulica das lagoas.
12

Avaliação da Comunidade Fitoplanctônica e Eficiência de um Sistema de Tratamento de Esgotos no Litoral de Pernambuco

PAIVA, Marcella Vianna Cabral 02 1900 (has links)
Submitted by Eduarda Figueiredo (eduarda.ffigueiredo@ufpe.br) on 2015-03-05T13:52:09Z No. of bitstreams: 2 Dissertação Marcella Paiva.pdf: 2534154 bytes, checksum: d60502a8904c9a7a4488b3f76b1ea25e (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T13:52:09Z (GMT). No. of bitstreams: 2 Dissertação Marcella Paiva.pdf: 2534154 bytes, checksum: d60502a8904c9a7a4488b3f76b1ea25e (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-02 / CNPq e FACEPE / As lagoas de estabilização são ambientes propícios ao desenvolvimento de cianobactérias, que potencialmente podem produzir toxinas e causar problemas de saúde a seres humanos e animais. Neste estudo avaliou-se a comunidade fitoplânctonica em uma estação de tratamento de esgotos, composta por reatores UASB, lagoa de polimento e filtros biológicos percoladores, no município de Rio Formoso. As coletas foram realizadas em 2011, durante seis meses, em dois horários (14h e 2h), com avaliação dos parâmetros físico-químicos, biológicos, climáticos e toxinas. Os resultados médios obtidos revelaram que a eficiência do tratamento é satisfatórias na remoção de DQO (84,5%), NTK (54,5%) e nitrogênio amoniacal (43,8%). Os valores de pH e oxigênio dissolvido na lagoa foram mais elevados na superfície às 14h, devido a influência das maiores temperatura e da atividade das algas no epilíminio. A análise de fitoplâncton constatou maior densidade (entre 3,89 x 107 cel/mL e 5,22 x 106 cel/mL), na superfície da lagoa às 14h. A espécie Oscillatoria limosa foi dominante em todos os meses de coleta. Contudo, no mês de junho houve uma mudança na composição da comunidade, com aumento da representatividade de Euglena sp. e Merismopedia tenuissima, provavelmente pelo aumento do nitrogênio amoniacal na lagoa. Após o tratamento nos filtros, ocorreu uma remoção significativa de algas (entre 90 e 99%), exceto no mês de junho (11%), possivelmente pela dominância de Euglena sp.e M.tenuissima. Não foi detectada a presença de microcistinas através dos métodos de HPLC e LC-MS.
13

Comparação e avaliação dos métodos colorimétricos utilizados para determinação de proteínas em lagoas de estabilização / Comparison and evaluation of colorimetric methods used to proteins determination in waste stabilization ponds

Miwa, Adriana Cristina Poli 21 February 2003 (has links)
As lagoas de estabilização representam um dos métodos mais simples utilizados para tratamento de esgoto sanitário. Grande parte da matéria orgânica presente no esgoto sanitário é constituída por proteínas, a qual torna-se fator limitante aos processos biológicos de tratamento de águas residuárias em que se encontram presentes. O objetivo deste trabalho foi avaliar e comparar métodos colorimétricos para determinação de proteínas, definindo qual é o mais apropriado para esse tipo de ambiente. Os métodos colorimétricos utilizados foram o de Lowry, de Bradford, do Biureto e do Ácido Bicinconínico. As proteínas padrões utilizadas foram soroalbumina, caseína e ovoalbumina. O método de Bradford apresentou várias desvantagens. Biureto I e III e proteína bruta medida a partir do Nitrogênio Total Kjeldah (NTK) apresentaram valores altos devido não medir somente proteínas. A quantidade de proteínas na amostra não foi suficiente para que ocorresse reação no método Biureto II. O método do Ácido Bicinconínico não reagiu com caseína e o custo do reagente é alto. Portanto, o método apropriado para esse tipo de amostra foi o Lowry que apresentou maior reprodutividade e sensitividade. Para comprovar esse resultado, uma análise de adição de padrão à amostra foi realizada para verificar se haviam substâncias interferentes, cujo resultado foi negativo / Stabilization ponds represent a simple method to treat sanitary sewage. A large part of the organic matter present in sanitary sewage consists of proteins, which become a limiting factor for the wastewater treatment in biological processes. The goal of this work was to evaluate and to compare colorimetric methods for protein determination, defining which is the more appropriate for this environment. The colorimetric methods used were the Folin-phenol, Bradford, Biuret and Bicinconinic Acid methods. The protein standards used were serum albumin bovin, casein and ovalbumin. The Bradford method introduced several disadvantages. Biuret I and III and brute protein introduced high values due don't measure only proteins. The proteins quantity in the sample wasn't enough so that it had occurred reaction in the Biuret II method. The method of Bicinconinic Acid didn't react with casein and the reagent cost is high. Therefore, the method appropriated for this sample was the Lowry that introduced larger reprodutivity and sensitivity. To prove this result, a standard addition analysis was performed to verify if there were interfering substances, whose result was negative
14

Influência do meio suporte e da presença de vegetação no desempenho de filtros biológicos percoladores / Influence of the filter media and the presence of vegetation at the performance of biological trickling filters

Martins, Vinícius Ferreira 15 February 2016 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-05-18T13:02:30Z No. of bitstreams: 1 texto completo.pdf: 1075107 bytes, checksum: 115269fdc25234332c893ca4b1000bcc (MD5) / Made available in DSpace on 2017-05-18T13:02:30Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1075107 bytes, checksum: 115269fdc25234332c893ca4b1000bcc (MD5) Previous issue date: 2016-02-15 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A situação precária do esgotamento sanitário no Brasil, juntamente com a demanda por sistemas de tratamento de esgoto que contemplem menores custos de implantação, operação e manutenção, faz da tecnologia da biomassa aderida, mais especificamente os filtros biológicos percoladores (FBPs) uma alternativa para o tratamento de esgotos sanitários no país. Visando ampliar os aspectos funcionais do sistema FBP, o presente estudo objetivou avaliar o desempenho de filtros biológicos percoladores com a inserção do capim-vetiver (Chrysopogon zizanioides) nos meios suporte brita e argila expandida, consistindo em uma nova abordagem para o tratamento de esgotos. Para isso, o experimento contou com quatro FBPs com diferentes configurações: FBP AV (argila expandida como substrato, cultivada com vetiver); FBP A (argila expandida como substrato, sem o cultivo de vetiver); FBP BV (brita no1 como substrato, cultivado com vetiver); e FBP B (brita no1 como substrato, sem o cultivo de vetiver). Como resultados as concentrações efluentes de DBO bruta foram de 142, 119, 104 e 120 mg L -1 para FBP AV , FBP A , FBP BV e FBP B , respectivamente, e comparando as concentrações notou-se diferença significativa para FBP A e FBP B provendo os melhores resultados para a DBO bruta. Para fósforo as médias efluentes foram de 6,63, 6,57, 6,42 e 5,61 mg L -1 para FBP AV , FBP A , FBP BV e FBP B , respectivamente e o meio suporte brita (FBP BV e FBP B ) diferiu significativamente da argila (FBP A e FBP AV ), na qual a brita proveu melhor resultado para a remoção de fósforo devido a sua capacidade de retenção e que a vegetação não contribuiu significativamente para a remoção desse parâmetro. As concentrações de nitrogênio total Kjeldahl (NTK) para efluente foram de 39,5, 43,1, 42,1 e 37,7 mg L -1 , nitrogênio amoniacal total (NAT) de 31, 37,9, 37,7 e 31,9 mg L -1 e nitrato de 0,352, 0,027, 0,057 e 0,104 mg L -1 correspondente aos filtros FBP AV , FBP A , FBP BV e FBP B . Analisando a série nitrogenada percebe-se uma tendência do filtro com o meio suporte brita (FBP B ) de se ser mais eficiente em remover as formas mais particuladas de nitrogênio (NTK) e o FBP AV (associação argila/vetiver) ser mais expressivo para as formas dissolvidas (NAT e nitrato). De maneira geral o meio suporte argila expandida e a inserção do capim-vetiver mostraram-se como boas alternativas para o tratamento de esgotos sanitários no FBP. / The precarious sewage management in Brazil together with the demand for low- cost and low-maintenance systems makes the attached biomass technology - specifically the trickling filters (TF) - an alternative for treatment of sewage in developing countries. Aiming to expand the functional aspects of the TF system, this study intended to evaluate the performance of TFs with grown vetiver grass (Chrysopogon zizanioides) in gravel and expanded clay substrates, consisting of a new approach for sewage treatment. Thus, the experiment had four TFs with different configurations: FBP AV (expanded clay media grown with vetiver); FBP A (expanded clay media without vegetation); FBP BV (gravel # 1 media grown with vetiver); and FBP B (gravel # 1 media without vegetation). The effluent concentrations of unfiltered BOD were 142, 119, 104 and 120 mg L -1 for FBP AV , FBP A , FBP BV and FBP B respectively and comparing the concentrations was noticed a statistical difference for FBP A and FBP B providing better results for unfiltered BOD. To phosphorus, the effluent means were 6.63, 6.57, 6.42 and 5.61 mg L -1 for FBP AV , FBP A , FBP BV and FBP B respectively and the gravel media (FBPB V and FBP B ) differed statistically from the expanded clay (FBP A and FBP AV ), where the gravel media provided better results for phosphorus removal due to its retention capacity and the vegetation do not contributed to this removal. The TKN effluent means were 39.5, 43.1, 42.1 and 37.7 mg L -1 , TAN were 31, 37.9, 37.7 and 31.9 mg L -1 and for nitrate 0.352, 0.027, 0.057 and 0.104 mg L -1 corresponding to FBP AV , FBP A , FBP BV and FBP B filters. Analyzing nitrogen series was noticed that gravel media (FBP B ) is more efficient in removing more particulate forms of nitrogen (TKN) and FBP AV (association clay / vetiver) is more expressive for more dissolved forms (TAN and nitrate). In general, booth the expanded clay media and the cultivation of grass vetiver seemed to be a good alternative for the treatment of wastewater in TFs.
15

Cultivo de microalgas em esgoto doméstico com utilização de sistemas híbridos: lagoas de alta taxa e biorreator em filme / Microalgae cultivation in domestic sewage with use of hybrid systems: high rate ponds and film bioreactor

Assis, Letícia Rodrigues de 16 February 2016 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-06-01T09:55:15Z No. of bitstreams: 1 texto completo.pdf: 2335941 bytes, checksum: 0811eebbff5e620a96857ef57f050c79 (MD5) / Made available in DSpace on 2016-06-01T09:55:16Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2335941 bytes, checksum: 0811eebbff5e620a96857ef57f050c79 (MD5) Previous issue date: 2016-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo teve como objetivo a avaliação do desempenho de sistemas híbridos na otimização do cultivo de biomassa e do tratamento de esgoto doméstico. Os sistemas híbridos se constituíram em lagoas de alta taxa (LATs) e reatores de crescimento de biofilme. Dois sistemas híbridos foram utilizados, sendo somente um com suplementação de COz no meio de cultivo da LAT. Um terceiro sistema composto por uma LAT convencional com adição de COz foi avaliado. No primeiro período de monitoramento foi realizada a suplementação de COz sintético em cilindro de gás com 99% de pureza, enquanto no segundo período, emissões atmosféricas provenientes da combustão da gasolina comum foram utilizadas, em substituição ao 002 sintético. Os resultados mostraram que as espécies Chlore/Ia vulgaris e Scenedesmus acutus foram predominantes em todos os sistemas de cultivos. O ambiente dos biofilmes favoreceu o desenvolvimento de diferentes microrganismos fitoplanctônicos daqueles observados nas LATs. As produtividades de clorofila a, nos dois períodos de monitoramento, foram entre 0,120 - 0,207; 0,106 - 0,132; 0,128 0,251 g.m'2.dia'1, respectivamente, para os sistemas híbridos com e sem adição de CO2 e para a LAT convencional com adição de 002. As eficiências de remoções médias de demanda química de oxigênio solúvel, carbono orgânico solúvel, nitrogênio amoniacal e fósforo solúvel em todas as LATs foram, respectivamente, na faixa de 9 - 46%; 21 - 58%, 67 - 84% e 20 - 30%. A concentração média da biomassa nos biofilmes foi entre 82 a 182 Kg.m'3, em base seca. A pesquisa mostrou que o sistema híbrido foi um eficiente sistema de cultivo algal, tratamento de esgoto doméstico, e colheita de biomassa de forma fácil e simples. / The present study aimed to evaluate the performance of hybrid systems in the optimization of cultivation of biomass and the treatment of domestic sewage. The hybrid systems constituted in high rate ponds (HRP) and biofilm growth reactors. Two hybrid systems were evaluated, with only one With COz supplementation. The third system was a HRP conventional with 002 addition. In the first monitoring period a synthetic COz supplementation was made in gas cylinder with 99% purity, while in the second period, atmospheric emissions from the combustion of gasoline were used, replacing the synthetic COz. The results showed that the species Ch/ore/Ia vulgaris and Scenedesmus acutus were predominant in all cultivation systems. The biofilm environment favored the development of different phytoplankton microorganisms those observed in HRP. The chlorophle-a productivity in the two monitoring periods were between 0,120 to 0,207; 0,106 to 0,132; 0,128 to 0,251 g.m'2.day'1, respectively, to hybrid systems with and without COz addition and conventional LAT with COz addition. Average soluble chemical oxygen demand, soluble organic carbon, ammonium nitrogen and soluble phosphorus in all systems were, respectively, 9 46%; 21 - 58%, 67 - 84% and 20 - 30%. Average concentration of biomass in biofilms was between 82-182 kg.m'3, dry weight. The research showed that the hybrid system was an efficient algal culture system, treatment of domestic sewage and easy and simple biomass harvest.
16

Utilização de esgoto tratado em sistema de lagoas de estabilização como água de amassamento e cura de concreto / Use of sewage treaty on the stabilisation lagoons system as moulding and maturing water of concrete

Silva, Jorge Luís Melo da 07 August 2008 (has links)
SILVA, J. L. M. Utilização de esgoto tratado em sistema de lagoas de estabilização como água de amassamento e cura de concreto. 2008. 125 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2008. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-13T17:18:18Z No. of bitstreams: 1 2008_dis_jlmsilva.pdf: 20136801 bytes, checksum: 27ba849288239f1966bb8cf546724a82 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-16T19:13:30Z (GMT) No. of bitstreams: 1 2008_dis_jlmsilva.pdf: 20136801 bytes, checksum: 27ba849288239f1966bb8cf546724a82 (MD5) / Made available in DSpace on 2016-05-16T19:13:30Z (GMT). No. of bitstreams: 1 2008_dis_jlmsilva.pdf: 20136801 bytes, checksum: 27ba849288239f1966bb8cf546724a82 (MD5) Previous issue date: 2008-08-07 / It was studied the feasibility here on a technical point of view, the use of a predominantly domestic sewage effluent comes from the treatment system for stabilising the lagoons of the CAGECE’s Station Treatment of Sewage, located in the city of Aquiraz-CE as moulding and curing water of concrete produced in the laboratory scale. In preliminary chemical analysis, the effluent analysis proved to be suitable for use in the production of concrete. The results for tests to determine the pH to 25°C, total solids, total iron, chlorides and sulfates soluble showed itself within the limits required. No significant difference was found between the results in the tests of time to handle with paste made of cement produced with the effluent analysis and those obtained with drinking water, according to the required limit of difference of 30min. Nor was detected significant difference between the results obtained in testing for resistance to compression of 07 and 28 days achieved with corpses-of-proof cylindrical shaped and cured with the effluent analysis and those obtained with drinking water, according to the required limit of difference of 10%. While the treated effluent had a distinctive smell not very pleasant, the portfolio of cement, concrete and produced the bodies proof-of-shaped unchanged against its perceived odor. It has been proved that, based on the standard requirements demanded by NM 137, the sewage effluent is considered appropriate for the proposed use. / Estudou-se aqui a viabilidade, sob ponto de vista técnico, da utilização de um efluente de esgoto predominantemente doméstico oriundo de sistema de tratamento por lagoas de estabilização da ETE da CAGECE, localizada no município de Aquiraz-CE, como água de amassamento e cura de concreto produzido em escala laboratorial. Em análise química preliminar, o efluente analisado mostrou-se adequado à utilização para a produção de concreto. Os resultados obtidos nos ensaios de determinação de pH a 25°C, sólidos totais, ferro total, cloretos e sulfatos solúveis mostraram-se dentro dos limites exigidos. Não foi constatada diferença significativa entre os resultados obtidos nos ensaios de tempo de pega realizados com pasta de cimento produzida com o efluente analisado e os obtidos com a água potável, obedecendo ao limite de diferença exigido de 30min. Também não foi constatada diferença significativa entre os resultados obtidos nos ensaios de resistência à compressão aos 07 e 28 dias realizados com corpos-de-prova cilíndricos moldados e curados com o efluente analisado e os obtidos com a água potável, obedecendo ao limite de diferença exigido de 10%. Embora o efluente tratado tivesse um odor característico não muito agradável, a pasta de cimento, o concreto produzido e os corpos-de-prova moldados não sofreram alterações perceptíveis em relação ao seu odor. Comprovou-se que, baseado nos requisitos exigidos pela norma NM 137, o efluente de esgoto analisado é adequado para a utilização proposta.
17

Avaliação de lagoas de lemnáceas no polimento de esgoto doméstico e produção de biomassa

Garcia, Daiane Cristina de Oliveira [UNESP] 12 January 2015 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:33:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-01-12. Added 1 bitstream(s) on 2015-06-18T12:48:25Z : No. of bitstreams: 1 000829477.pdf: 757893 bytes, checksum: 948eaa3b1fa969d9c288898c4ca8dea7 (MD5) / Lagoas com macrófitas flutuantes, em especial as lemnáceas, tem sido satisfatoriamente utilizadas para o polimento de esgoto, gerando uma expressiva quantidade de biomassa. Estas plantas utilizam os nutrientes (N e P) presentes no esgoto para o seu desenvolvimento, concentrando-os em sua biomassa e disponibilizando-os para sua recuperação. Desse modo, uma estação de tratamento de esgoto pode trabalhar de forma integrada e sustentável, ou seja, lemnáceas podem ser cultivadas concomitantemente com o tratamento de esgoto. Esta pesquisa teve como objetivo avaliar a viabilidade de tratamento terciário de esgoto doméstico integrado à produção das lemnáceas. O experimento foi realizado em escala piloto, em tanque com volume de 0,44 m 3 , utilizando o efluente de lagoa de estabilização da ETE do município de Ilha Solteira para o seu polimento através de lagoas de lemnáceas em tanque com fluxo contínuo de 0,12 m 3 /dia, e TDH de 3,8 dias. Amostras do efluente foram coletadas antes e após o tratamento em tanque de lemnas, sendo realizadas análises diárias (pH, OD e temperatura), duas vezes por semana (NT, PT e DQO) e semanalmente (ST, DBO 5 , coliformes totais e E. coli). As lemnas foram colhidas em três frequências de colheita diferentes, a cada 7, 14 e 21 dias, para quantificação de sua produção. As maiores eficiências de remoção de NT, PT, DQO e DBO 5 foram de 74, 67%, 66,18%, 88,12% e 91,14%, respectivamente. Para E. coli e coliformes totais observou-se uma redução média de 1 unidade logarítmica. Entretanto, as eficiências de remoção de sólidos totais foram mais baixas, sendo a maior eficiência de 48,90%. A maior taxa de produção foi das lemnas colhidas a cada 14 dias (5,6 g/m 2 /dia de matéria seca). A análise de variância (ANOVA) demonstrou diferença significativa apenas para as variáveis pH, OD, temperatura, DQO e DBO 5 . O sistema de tratamento avaliado obteve resultados positivos na redução da ... / Stabilization ponds using floating macrophytes, especially duckweeds, have been successfully used for wastewater polishing. This plant use the nutrients (N and P) present in the wastewater for their growth, concentrating them in their biomass and making them available for recovery. Thus, a wastewater treatment plant can work in integrated and sustainable manner, duckweeds can be grown concomitantly with the wastewater treatment. This research aimed to assess the feasibility of tertiary treatment of municipal wastewater integrated the duckweed production. The experiments was conducted in pilot scale, in pond with a volume of 0,44 m 3 , using the stabilization pond effluent from wastewater treatment plant in the municipality of Ilha Solteira-SP for duckweed growth in pond with continuous flow of 0,12 m 3 /day and HRT of 3,8 days. Effluents samples were collected before and after duckweeds ponds, daily analyses (pH, DO and temperature), twice a week (TN, TP and COD) and weekly (total solids, total coliforms and E. coli) were carried out. The duckweeds were harvested with three different frequencies, every 7, 14 and 21 days for quantification of its production. The highest efficiencies of TN, TP, COD and BOD 5 were 74,67%, 66,18%, 88,12% and 91,14%, respectively. E. coli and total coliforms obtained a reduction of 1 log unit. However, the removal efficiencies of total solids were lower, the highest efficiency were 48,90%. Analysis of variance (ANOVA) showed significant differences only for the variables pH, DO, temperature, COD and BOD 5 . The highest duckweeds production rate were harvested every 14 days (5,6 g/m 2 /day dry matter). The assessed treatment system obtained positive results in the reduction of analyzed variables concentrations being an efficient technology with simple operation for domestic wastewater polishing. There have been large variations in duckweed density and production rate, could be associated with effluent ...
18

Caracterização da qualidade de efluente e a possível utilização do resíduo como fonte energética

Souza, Ivan Fernandes de [UNESP] 23 May 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-05-23Bitstream added on 2014-06-13T19:31:33Z : No. of bitstreams: 1 souza_if_me_botfca.pdf: 1055023 bytes, checksum: 319afaa26bb2759f1cb407bee3b45876 (MD5) / Universidade Estadual Paulista (UNESP) / Nesta pesquisa estudou-se a qualidade do efluente do Câmpus da UNESP em Botucatu, distrito de Rubião Junior, tratado através do sistema de lagoas de estabilização de esgoto sanitário, além do potencial energético produzido pelo resíduo da última lagoa aeróbia. Este trabalho foi realizado, no Departamento de Química e Bioquímica do Instituto de Biociências da Universidade Estadual Paulista, Câmpus de Botucatu. Com esse propósito foram analisados a qualidade do efluente tratado, através da determinação de alguns parâmetros físico-químicos, espécies químicas e teores de metais, já no resíduo sólido foram analisados o potencial energético, através do poder calorífico e teores de metais. A qualidade do efluente tratado e resíduo foram estudadas no período de nove meses (mar/04 a nov/04) com freqüência mensal, dividida em duas estações predominantes, a chuvosa e a seca, com o objetivo de detectar possíveis alterações no comportamento do sistema. Foram determinadas as seguintes variáveis: temperatura do ar e do efluente, potencial hidrogeniônico, condutividade elétrica, turbidez, sólidos sedimentáveis, óleos e graxas, demanda química de oxigênio, demanda bioquímica de oxigênio, carbono orgânico total, nitrogênio amoniacal e teores de metais (cádmio, cobalto, cobre, ferro, níquel, chumbo e zinco) para o efluente. Para o resíduo, foram determinados o poder calorífico e os mesmos metais. Os resultados obtidos mostraram que não houveram diferenças significativas entre os pontos de coleta, os períodos de seca e de chuva, também não produziram alterações significativas no comportamento do sistema. De maneira geral, os resultados obtidos dos parâmetros e metais... / In this study, the effluent quality from UNESP Campus in Botucatu, Rubião Junior district was studied. Such effluent is treated using the sanitary sewer stabilization lagoons system. Also, the energetic potential which is yielded from the last aerobic lagoon residue. This study was performed at Departamento de Química e Bioquímica in Instituto de Biociências in Universidade Estadual Paulista, Botucatu Campus. With this purpose, the quality of the effluent treated was assessed, by means of the determination of some physical and chemical parameters, chemical species and metal rates. On the solid residue, the energetic potential was assessed by means of calorific power and metal rates. The quality of the effluent treated and its residue were studied in a nine-month period (Mar./04 to Nov.04) monthly, divided in two predominant seasons, the rainy one and the dry one, aiming to detect possible changes in the system behavior. The following variables were determined: air and effluent temperature, hydrogenionic potential, electrical conductivity, turbidity, sedimentable solids, oils and greases, chemical oxygen demands, biochemical oxygen demands, total organic carbon, ammoniac nitrogen and metal rates (cadmium, cobalt, copper, iron, nickel, lead and zinc) to the effluent. For the residue, the calorific power and the same metals were determined. The obtained results showed that there were no significant differences between the collection points, the dry and rainy periods, also did not produce significant changes in the system behavior. Generally speaking, the obtained results from the parameters and metals...(Complete abstract click electronic access below)
19

Avaliação de lagoas de lemnáceas no polimento de esgoto doméstico e produção de biomassa /

Garcia, Daiane Cristina de Oliveira. January 2015 (has links)
Orientador: Liliane Lazzari Albertin / Banca: Maurício Augusto Leite / Banca: Rodrigo de Almeida Mohedano / Resumo: Lagoas com macrófitas flutuantes, em especial as lemnáceas, tem sido satisfatoriamente utilizadas para o polimento de esgoto, gerando uma expressiva quantidade de biomassa. Estas plantas utilizam os nutrientes (N e P) presentes no esgoto para o seu desenvolvimento, concentrando-os em sua biomassa e disponibilizando-os para sua recuperação. Desse modo, uma estação de tratamento de esgoto pode trabalhar de forma integrada e sustentável, ou seja, lemnáceas podem ser cultivadas concomitantemente com o tratamento de esgoto. Esta pesquisa teve como objetivo avaliar a viabilidade de tratamento terciário de esgoto doméstico integrado à produção das lemnáceas. O experimento foi realizado em escala piloto, em tanque com volume de 0,44 m 3 , utilizando o efluente de lagoa de estabilização da ETE do município de Ilha Solteira para o seu polimento através de lagoas de lemnáceas em tanque com fluxo contínuo de 0,12 m 3 /dia, e TDH de 3,8 dias. Amostras do efluente foram coletadas antes e após o tratamento em tanque de lemnas, sendo realizadas análises diárias (pH, OD e temperatura), duas vezes por semana (NT, PT e DQO) e semanalmente (ST, DBO 5 , coliformes totais e E. coli). As lemnas foram colhidas em três frequências de colheita diferentes, a cada 7, 14 e 21 dias, para quantificação de sua produção. As maiores eficiências de remoção de NT, PT, DQO e DBO 5 foram de 74, 67%, 66,18%, 88,12% e 91,14%, respectivamente. Para E. coli e coliformes totais observou-se uma redução média de 1 unidade logarítmica. Entretanto, as eficiências de remoção de sólidos totais foram mais baixas, sendo a maior eficiência de 48,90%. A maior taxa de produção foi das lemnas colhidas a cada 14 dias (5,6 g/m 2 /dia de matéria seca). A análise de variância (ANOVA) demonstrou diferença significativa apenas para as variáveis pH, OD, temperatura, DQO e DBO 5 . O sistema de tratamento avaliado obteve resultados positivos na redução da ... / Abstract: Stabilization ponds using floating macrophytes, especially duckweeds, have been successfully used for wastewater polishing. This plant use the nutrients (N and P) present in the wastewater for their growth, concentrating them in their biomass and making them available for recovery. Thus, a wastewater treatment plant can work in integrated and sustainable manner, duckweeds can be grown concomitantly with the wastewater treatment. This research aimed to assess the feasibility of tertiary treatment of municipal wastewater integrated the duckweed production. The experiments was conducted in pilot scale, in pond with a volume of 0,44 m 3 , using the stabilization pond effluent from wastewater treatment plant in the municipality of Ilha Solteira-SP for duckweed growth in pond with continuous flow of 0,12 m 3 /day and HRT of 3,8 days. Effluents samples were collected before and after duckweeds ponds, daily analyses (pH, DO and temperature), twice a week (TN, TP and COD) and weekly (total solids, total coliforms and E. coli) were carried out. The duckweeds were harvested with three different frequencies, every 7, 14 and 21 days for quantification of its production. The highest efficiencies of TN, TP, COD and BOD 5 were 74,67%, 66,18%, 88,12% and 91,14%, respectively. E. coli and total coliforms obtained a reduction of 1 log unit. However, the removal efficiencies of total solids were lower, the highest efficiency were 48,90%. Analysis of variance (ANOVA) showed significant differences only for the variables pH, DO, temperature, COD and BOD 5 . The highest duckweeds production rate were harvested every 14 days (5,6 g/m 2 /day dry matter). The assessed treatment system obtained positive results in the reduction of analyzed variables concentrations being an efficient technology with simple operation for domestic wastewater polishing. There have been large variations in duckweed density and production rate, could be associated with effluent ... / Mestre
20

Avaliação da viabilidade e aplicabilidade de macrófitas aquáticas para polimento de efluentes de estações de tratamento de esgoto doméstico - estudo em escala real /

Affonseca, Mario Eduardo Pardini, 1990. January 2016 (has links)
Orientador: Eduardo Luiz de Oliveira / Banca: Roberto Lyra Villas Bôas / Banca: Claudia Maria Gomes de Quevedo / Resumo: Vários estudos já foram realizados no Brasil, a grande maioria em escala de bancada, para avaliação da eficiência de remoção de nutrientes através do uso de macrófitas, atestando a sua viabilidade técnica. Os sistemas de tratamento de esgoto doméstico por lagoas não removem fósforo e nem a amônia, o que tem gerado uma série de problemas para atendimento às exigências legais brasileiras para a qualidade de corpos d'água que recebem esses efluentes. Além disso, o excesso de nutrientes ocasiona problemas ambientais que podem inviabilizar outros usos para esses recursos naturais. A ampla disseminação da tecnologia de tratamento por lagoas de estabilização se deu pelo baixo custo de implantação e operação, e pelos bons resultados para a remoção de parâmetros até o nível secundário. Portanto, o país possui um passivo ambiental significativo, o qual requer melhorias para que se ajuste à realidade que se busca alcançar com as restrições pelos órgãos ambientais e pelo arcabouço legal atualmente existente. Neste trabalho foram realizadas duas baterias de testes em escala real na Lagoa da Estação de Tratamento de Recreio, no Município de Charqueada, SP. Os testes foram feitos em dois períodos sazonais completamente distintos, e demonstraram que as variáveis ambientais como radiação solar, ventos e chuvas exercem influencia direta na capacidade de desenvolvimento e remoção de nitrogênio e fósforo para o grupo de macrófitas Lemnaceae, que se encontrava naturalmente instalado nesse sistema... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Several studies have been conducted in Brazil, the vast majority in bench scale to evaluate the nutrient removal efficiency through the use of macrophytes, attesting to their technical feasibility. Domestic wastewater treatment systems for ponds do not remove phosphorus neither ammonia, which has generated a number of problems to meet the Brazilian legal requirements for the quality of water bodies receiving these effluents. Furthermore, the excess of nutrients causes environmental problems that may prevent other uses for these resources. The wide spread treatment technology by stabilization ponds was due to the low cost of deployment and operation, and the good results for the removal of parameters to the secondary level. Therefore, the country has a significant environmental liability, which requires improvements to fit the reality that seeks to achieve with the restrictions by environmental agencies and the currently existing legal framework. In this work were two full-scale test batteries in the Lagoon Recreational Treatment Plant in the Municipality of Recreio, SP. The tests were done in two completely different seasonal periods, and demonstrated that environmental variables such as solar radiation, wind and rain have a direct influence on the development capacity and nutrient removal for macrophyte group Lemnaceae which found itself naturally installed on this system . Nevertheless, the results were very promising, reaching mean removal of 75% for both parameters, with ... (Complete abstract click electronic access below) / Mestre

Page generated in 0.4668 seconds