41

Einfluss intermetallischer Phasen der Systeme Al-Cu und Al-Ag auf den Widerstand stromtragender Verbindungen im Temperaturbereich von 90 °C bis 200 °C

Pfeifer, Stephanie 27 October 2016 (has links) (PDF)
Im Netz der Elektroenergieversorgung werden einzelne Netzkomponenten und Betriebsmittel durch Verbindungen elektrisch zusammengeschaltet. Dabei werden häufig Schraubenverbindungen mit Stromschienen eingesetzt. Diese müssen über mehrere Jahrzehnte zuverlässig hohe Ströme tragen können. Abhängig von der sich einstellenden Temperatur an den Verbindungen altern diese mit der Zeit. Die Alterung wird je nach Verbindungssystem von verschiedenen Mechanismen beeinflusst, die alle parallel ablaufen. Bei ruhenden, stationären elektrotechnischen Verbindungen, deren Kontaktpartner aus verschiedenen Materialien bestehen, können abhängig von der Paarung intermetallische Phasen (IMP) entstehen. Die sich bildenden IMP haben schlechtere elektrische und mechanische Eigenschaften als die reinen Metalle. Daraus resultiert ein höherer Verbindungswiderstand. Die erzeugte Verlustleistung sowie die Temperatur der Verbindung steigen an. Dies kann zum Ausfall der Verbindung führen. In der Elektroenergietechnik werden aufgrund ihrer guten elektrischen Leitfähigkeit häufig die Werkstoffe Aluminium und Kupfer sowie das Beschichtungsmetall Silber bei Temperaturen von üblicherweise 90 °C bis 200 °C eingesetzt. Speziell bei Aluminium-Kupfer-Verbindungen, die nicht langzeitstabil sind, wird als maßgebliche Ausfallursache das Bilden von IMP gesehen. Die IMP des Systems Al-Cu wurden in der Vergangenheit bereits vielfach untersucht. Das Übertragen der Ergebnisse auf die Problematik stromtragender Verbindungen der Elektroenergietechnik ist jedoch nicht ohne Weiteres möglich. Der relevante niedrige Temperaturbereich zwischen 90 °C und 200 °C spielt bei vielen Untersuchungen nur eine untergeordnete Rolle. Zusätzlich können die Eigenschaften der IMP bei unterschiedlichen Herstellungsverfahren voneinander abweichen. Zum System Al-Ag ist in der Literatur nur wenig bekannt. Deshalb wurden für diese Arbeit phasenreine IMP der Systeme Al-Cu und Al-Ag mit unterschiedlichen Herstellungsverfahren bei möglichst identischen Randbedingungen hergestellt. Diese wurden mit einer speziell für diese Proben entwickelten Messeinrichtung elektrisch charakterisiert und der ermittelte spezifische elektrische Widerstand der IMP und ihr Temperaturbeiwert mit Werten aus der Literatur verglichen. An verschiedenen Schraubenverbindungen mit Stromschienen aus Aluminium und Kupfer wurden Langzeitversuche von bis zu 3 Jahren durchgeführt. Der Verbindungswiderstand wurde abhängig von der Zeit ermittelt. An ausgewählten Verbindungen wurde zusätzlich in zwei identischen Versuchen der Einfluss der Belastung mit Dauer- und Wechsellast auf das Langzeitverhalten untersucht. Mithilfe der an den IMP ermittelten elektrischen Eigenschaf-ten wurde deren Einfluss auf den Verbindungswiderstand berechnet. Die Ergebnisse dieser Modellrechnung wurden mit den Ergebnissen aus den Langzeitversuchen verglichen. Ausgewählte Verbindungen wurden dazu mikroskopisch untersucht. Es wurde festgestellt, dass die IMP nicht ausschließlich das Langzeitverhalten stromtragender Verbindungen bestimmen. Es muss mindestens ein weiterer Alterungsmechanismus einen signifikanten Einfluss haben. Die Untersuchungen deuten darauf hin, dass dabei Sauerstoff eine zentrale Rolle spielen könnte. / In electrical power supply networks a huge number of electrical joints are used to connect transmission lines, conductors, switchgears and other components. During operation these joints are aging due to different aging mechanisms. Depending on the type of the joint several aging mechanisms can take place at the same time. For stationary joints with contact partners made of different materials, the formation of intermetallic compounds (IMC) may be an issue. These IMC have worse electrical and mechanical properties compared to the pure metals. Therefore, the presence of IMC in the contact area results in a higher joint re-sistance and the temperature and the thermal power losses increase. Typical temperatures for high current joints are between 90 °C and 200 °C. Due to their good electrical conductivity aluminum and copper are often used as conductor materials and silver as a coating material. Especially bimetal joints made of aluminum and copper are not long term stable. The formation of Al-Cu IMC is held responsible as a cause of failure. The IMC of the System Al-Cu have already been studied by several authors. However, it is difficult to apply the results directly to electrical joints in power supply networks. In many studies the low temperature range between 90 °C and 200 °C is not regarded. In addition, the properties of the IMC may vary due to different preparation processes. There is only little information about the system Al-Ag in the literature. For this work, phase pure IMC of the systems Al-Cu and Al-Ag were prepared by different preparation processes using similar process parameters. These IMC samples were electrically characterized with a specially developed measuring device. The specific electric resistivity and the temperature coefficient of resistance were determined and compared to values taken from the literature. Various combinations of bus bar joints made of aluminum and copper were investigated in long term tests for up to three years. The joint resistance was determined as a function of time. In addition, for selected joints two identic setups were operated with continuous load and alternating load. The long term behavior was investigated with regard to the load ap-plied. Using the results of the electrical characterization of the IMC their influence on the joint resistance was calculated theoretically. The results of the calculation were compared to the results determined in the long term tests. Selected joints were examined microscopi-cally after termination of the long term tests. It was found, that the long term behavior of bimetal electrical joints with the combination Al-Cu and Al-Ag cannot be exclusively described by the growth of IMC. At least there is one further aging mechanism involved. The studies suggest, that oxygen may have a significant influence.
42

Elektrisch‐thermisches Betriebs‐ und Langzeitverhalten hochstromtragfähiger Kontaktelemente

Gatzsche, Michael 12 January 2017 (has links) (PDF)
In Geräten und Anlagen des Stromnetzes werden Steckverbinder mit hoher Stromtragfähigkeit eingesetzt, wenn bewegliche Teile kontaktiert werden oder Betriebsmittel mit geringem Aufwand montier- und demontierbar sein müssen. Die elektrische Verbindung der Leiter wird dabei oft mit federnden Kontaktelementen realisiert. Die Kontaktelemente müssen als Teil der Strombahn während der Lebensdauer des Geräts den Betriebsstrom im Kiloampere-Bereich und im Fehlerfall bis zu einige Sekunden lang den eine Größenordnung höheren Kurzschlussstrom tragen. In der vorliegenden Arbeit wurden Rechenmodelle für die innere Erwärmung von Hochstrom-Kontaktsystemen im stationären Dauerbetrieb und im transienten Kurzschlussfall entwickelt. Das elektrische und mechanische Langzeitverhalten im Temperaturbereich (105…180) °C wurde experimentell mit stromdurchflossenen, fettgeschmierten Modellsteckverbindern, die regelmäßig getrennt und neu gesteckt wurden, untersucht. Modellerstellung, Rechnungen und Versuche wurden beispielhaft mit Kontaktelementen vom Typ Multilam durchgeführt. Kontaktelemente und Leiter bestanden aus versilbertem Kupfer. Für das stationäre Betriebsverhalten wurden die mit der analytischen Spannungs-Temperatur-Beziehung nach Kohlrausch berechneten Ergebnisse mit einem Erwärmungsversuch verifiziert. Die Temperaturdifferenz zwischen Kontaktelement und Leiter ist bei Standardanwendungen, wie in Schaltanlagen, mit ≤ 3 K sehr klein. Deshalb ist die Leitertemperatur als Zielgröße beim Dimensionieren der Dauerstrombelastbarkeit ausreichend. Bei Kurzschlussstrombelastung wurde im Kontaktsystem eine schnelle, räumlich unterschiedlich ausgeprägte Erwärmung numerisch berechnet. Leiter und Kontaktelement erwärmen sich kontinuierlich, wobei die mittlere Endübertemperatur im Kontaktelement aufgrund des kleineren stromtragenden Querschnitts eine Größenordnung höher ist. Die Kontakte führen bei 50 Hz-Wechselstrom aufgrund ihrer vernachlässigbaren Wärmekapazität 100 Hz-Temperaturzyklen aus. Dabei können die Maximaltemperaturen noch deutlich größer als die mittlere Temperatur der Kontaktelemente sein. Im Langzeitversuch waren nach 16 000 h Betriebszeit bei 180 °C und regelmäßigen simulierten Steckvorgängen die Verbindungskräfte noch genügend groß, um die elektrischen Anforderungen eines neuen Kontaktsystems zu erfüllen. Allerdings führte bei einer Betriebstemperatur von 105 °C ein thermisch instabiles Schmierfett zum vorzeitigen elektrischen Ausfall eines Teils der Steckverbinder. / Switchgear and devices for the power grid use high-power connectors if moving parts have to be contacted or equipment shall be easily mountable and dismountable. The electrical connection of the conductors is often realized by spring-loaded contact elements. As part of the main circuit, contact elements must carry the full operating current in the kiloampere-range for the entire service life of the device. In case of a fault, the short-circuit current, which is one order of magnitude larger, has to be carried for up to several seconds. In this thesis, calculation models for the inner temperature rise of high-power contact systems in steady-state continuous operation, as well as for the transient short-circuit load case were developed. Electrical and mechanical long-term performance in the temperature range from 105 to 180 °C was experimentally investigated with current carrying, grease-lubricated model connectors which were regularly unplugged and replugged. Modelling, calculations and experiments were exemplarily carried out with Multilam contact elements. Conductors and contact element consisted of silver-plated copper. The analytical voltage-temperature relation was used to calculate the steady-state performance; calculations were verified with a temperature-rise test. The temperature difference from contact element to conductors is very small (≤ 3 K) for standard applications like switchgear. Thus, it is sufficient to use the conductor temperature as a criterion for the design of the continuous ampacity of high-power contact systems. At short-time load, a fast spatially inhomogeneous temperature rise was numerically calculated. Conductor and contact element continuously heat up; due to the smaller current carrying cross section, median final temperature rise in the contact element is one order of magnitude larger than in the conductors. Because of their negligible thermal capacity, contacts perform 100 Hz temperature cycles at 50 Hz AC load; the maximum contact temperatures may be significantly higher than the median temperature of the contact elements. In the long-term test, after 16 000 h operating time at 180 °C and regular plugging operations, contact elements maintained enough joint force to meet the requirements of a new contact system. At 105 °C however, a thermally instable grease led to electrical failure of part of the connectors.
43

Prognose des Langzeitverhaltens von Textilbeton-Tragwerken mit rekurrenten neuronalen Netzen

Freitag, Steffen, Graf, Wolfgang, Kaliske, Michael 03 June 2009 (has links) (PDF)
Zur Prognose des Langzeitverhaltens textilbetonverstärkter Tragwerke wird ein modellfreies Vorgehen auf Basis rekurrenter neuronaler Netze vorgestellt. Das Vorgehen ermöglicht die Prognose zeitveränderlicher Strukturantworten unter Berücksichtigung der gesamten Belastungsgeschichte. Mit unscharfen Größen aus Messungen an Versuchstragwerken werden rekurrente neuronale Netze trainiert. Anschließend ist die unscharfe Prognose des Tragverhaltens möglich.
44

Migrationsbeständigkeit von Al- und Cu-Metallisierungen in SAW-Bauelementen / Resistance against migration in Al and Cu metallizations for SAW devices

Pekarcikova, Marcela 20 December 2005 (has links) (PDF)
Im Rahmen dieser Arbeit wurde die Akustomigrationsresistenz von in Kupfertechnologie hergestellten SAW-Strukturen charakterisiert und diese mit dem Schädigungsverhalten von Al-basierten SAW-Strukturen unter gleichen Belastungsbedingungen verglichen. Dies wurde durch die Anwendung einer speziellen Power-SAW-Teststruktur ermöglicht. Das Schädigungsniveau wurde hierbei über die irreversible Verschiebung der Peakfrequenz bzw. durch Änderungen im elektrischen Widerstand sowie durch mikroskopische Untersuchung der Mikrostruktur beurteilt. Die durchgeführten SAW-Belastungsexperimente mit HF-Leistungen bis zu 4,5 W zeigten, dass das entwickelte Ta-Si-N/Cu/Ta-Si-N-System im Vergleich zur Al/Ti-Metallisierung eine Akustomigrationsresistenz besitzt, die um mehr als drei Größenordnungen höher ist als jene der Al/Ti-Metallisierung. Hohe SAW-Belastungen verursachten sowohl im Al- als auch im Cu-Testwandler Hügel- und Lochbildung. Während die Hügel in der Al/Ti-Metallisierung senkrecht zur Oberfläche bis zu einer Höhe von 1 µm und die Löcher bis hinab an die Ti-Schicht wuchsen, bildeten sich in den extrem belasteten Cu-basierten Wandlern nur flache Hügel und schmale Löcher aus, welche noch mit der Deckschicht vollständig bedeckt waren. Anhand von REM/EBSD, TEM sowie FIB-Untersuchungen konnte ein relevanter Zusammenhang zwischen der Mikrostruktur und dem Schädigungsverhalten aufgezeigt werden.
45

Einfluss intermetallischer Phasen der Systeme Al-Cu und Al-Ag auf den Widerstand stromtragender Verbindungen im Temperaturbereich von 90 °C bis 200 °C

Pfeifer, Stephanie 26 October 2015 (has links)
Im Netz der Elektroenergieversorgung werden einzelne Netzkomponenten und Betriebsmittel durch Verbindungen elektrisch zusammengeschaltet. Dabei werden häufig Schraubenverbindungen mit Stromschienen eingesetzt. Diese müssen über mehrere Jahrzehnte zuverlässig hohe Ströme tragen können. Abhängig von der sich einstellenden Temperatur an den Verbindungen altern diese mit der Zeit. Die Alterung wird je nach Verbindungssystem von verschiedenen Mechanismen beeinflusst, die alle parallel ablaufen. Bei ruhenden, stationären elektrotechnischen Verbindungen, deren Kontaktpartner aus verschiedenen Materialien bestehen, können abhängig von der Paarung intermetallische Phasen (IMP) entstehen. Die sich bildenden IMP haben schlechtere elektrische und mechanische Eigenschaften als die reinen Metalle. Daraus resultiert ein höherer Verbindungswiderstand. Die erzeugte Verlustleistung sowie die Temperatur der Verbindung steigen an. Dies kann zum Ausfall der Verbindung führen. In der Elektroenergietechnik werden aufgrund ihrer guten elektrischen Leitfähigkeit häufig die Werkstoffe Aluminium und Kupfer sowie das Beschichtungsmetall Silber bei Temperaturen von üblicherweise 90 °C bis 200 °C eingesetzt. Speziell bei Aluminium-Kupfer-Verbindungen, die nicht langzeitstabil sind, wird als maßgebliche Ausfallursache das Bilden von IMP gesehen. Die IMP des Systems Al-Cu wurden in der Vergangenheit bereits vielfach untersucht. Das Übertragen der Ergebnisse auf die Problematik stromtragender Verbindungen der Elektroenergietechnik ist jedoch nicht ohne Weiteres möglich. Der relevante niedrige Temperaturbereich zwischen 90 °C und 200 °C spielt bei vielen Untersuchungen nur eine untergeordnete Rolle. Zusätzlich können die Eigenschaften der IMP bei unterschiedlichen Herstellungsverfahren voneinander abweichen. Zum System Al-Ag ist in der Literatur nur wenig bekannt. Deshalb wurden für diese Arbeit phasenreine IMP der Systeme Al-Cu und Al-Ag mit unterschiedlichen Herstellungsverfahren bei möglichst identischen Randbedingungen hergestellt. Diese wurden mit einer speziell für diese Proben entwickelten Messeinrichtung elektrisch charakterisiert und der ermittelte spezifische elektrische Widerstand der IMP und ihr Temperaturbeiwert mit Werten aus der Literatur verglichen. An verschiedenen Schraubenverbindungen mit Stromschienen aus Aluminium und Kupfer wurden Langzeitversuche von bis zu 3 Jahren durchgeführt. Der Verbindungswiderstand wurde abhängig von der Zeit ermittelt. An ausgewählten Verbindungen wurde zusätzlich in zwei identischen Versuchen der Einfluss der Belastung mit Dauer- und Wechsellast auf das Langzeitverhalten untersucht. Mithilfe der an den IMP ermittelten elektrischen Eigenschaf-ten wurde deren Einfluss auf den Verbindungswiderstand berechnet. Die Ergebnisse dieser Modellrechnung wurden mit den Ergebnissen aus den Langzeitversuchen verglichen. Ausgewählte Verbindungen wurden dazu mikroskopisch untersucht. Es wurde festgestellt, dass die IMP nicht ausschließlich das Langzeitverhalten stromtragender Verbindungen bestimmen. Es muss mindestens ein weiterer Alterungsmechanismus einen signifikanten Einfluss haben. Die Untersuchungen deuten darauf hin, dass dabei Sauerstoff eine zentrale Rolle spielen könnte. / In electrical power supply networks a huge number of electrical joints are used to connect transmission lines, conductors, switchgears and other components. During operation these joints are aging due to different aging mechanisms. Depending on the type of the joint several aging mechanisms can take place at the same time. For stationary joints with contact partners made of different materials, the formation of intermetallic compounds (IMC) may be an issue. These IMC have worse electrical and mechanical properties compared to the pure metals. Therefore, the presence of IMC in the contact area results in a higher joint re-sistance and the temperature and the thermal power losses increase. Typical temperatures for high current joints are between 90 °C and 200 °C. Due to their good electrical conductivity aluminum and copper are often used as conductor materials and silver as a coating material. Especially bimetal joints made of aluminum and copper are not long term stable. The formation of Al-Cu IMC is held responsible as a cause of failure. The IMC of the System Al-Cu have already been studied by several authors. However, it is difficult to apply the results directly to electrical joints in power supply networks. In many studies the low temperature range between 90 °C and 200 °C is not regarded. In addition, the properties of the IMC may vary due to different preparation processes. There is only little information about the system Al-Ag in the literature. For this work, phase pure IMC of the systems Al-Cu and Al-Ag were prepared by different preparation processes using similar process parameters. These IMC samples were electrically characterized with a specially developed measuring device. The specific electric resistivity and the temperature coefficient of resistance were determined and compared to values taken from the literature. Various combinations of bus bar joints made of aluminum and copper were investigated in long term tests for up to three years. The joint resistance was determined as a function of time. In addition, for selected joints two identic setups were operated with continuous load and alternating load. The long term behavior was investigated with regard to the load ap-plied. Using the results of the electrical characterization of the IMC their influence on the joint resistance was calculated theoretically. The results of the calculation were compared to the results determined in the long term tests. Selected joints were examined microscopi-cally after termination of the long term tests. It was found, that the long term behavior of bimetal electrical joints with the combination Al-Cu and Al-Ag cannot be exclusively described by the growth of IMC. At least there is one further aging mechanism involved. The studies suggest, that oxygen may have a significant influence.
46

Elektrisch‐thermisches Betriebs‐ und Langzeitverhalten hochstromtragfähiger Kontaktelemente

Gatzsche, Michael 12 January 2017 (has links)
In Geräten und Anlagen des Stromnetzes werden Steckverbinder mit hoher Stromtragfähigkeit eingesetzt, wenn bewegliche Teile kontaktiert werden oder Betriebsmittel mit geringem Aufwand montier- und demontierbar sein müssen. Die elektrische Verbindung der Leiter wird dabei oft mit federnden Kontaktelementen realisiert. Die Kontaktelemente müssen als Teil der Strombahn während der Lebensdauer des Geräts den Betriebsstrom im Kiloampere-Bereich und im Fehlerfall bis zu einige Sekunden lang den eine Größenordnung höheren Kurzschlussstrom tragen. In der vorliegenden Arbeit wurden Rechenmodelle für die innere Erwärmung von Hochstrom-Kontaktsystemen im stationären Dauerbetrieb und im transienten Kurzschlussfall entwickelt. Das elektrische und mechanische Langzeitverhalten im Temperaturbereich (105…180) °C wurde experimentell mit stromdurchflossenen, fettgeschmierten Modellsteckverbindern, die regelmäßig getrennt und neu gesteckt wurden, untersucht. Modellerstellung, Rechnungen und Versuche wurden beispielhaft mit Kontaktelementen vom Typ Multilam durchgeführt. Kontaktelemente und Leiter bestanden aus versilbertem Kupfer. Für das stationäre Betriebsverhalten wurden die mit der analytischen Spannungs-Temperatur-Beziehung nach Kohlrausch berechneten Ergebnisse mit einem Erwärmungsversuch verifiziert. Die Temperaturdifferenz zwischen Kontaktelement und Leiter ist bei Standardanwendungen, wie in Schaltanlagen, mit ≤ 3 K sehr klein. Deshalb ist die Leitertemperatur als Zielgröße beim Dimensionieren der Dauerstrombelastbarkeit ausreichend. Bei Kurzschlussstrombelastung wurde im Kontaktsystem eine schnelle, räumlich unterschiedlich ausgeprägte Erwärmung numerisch berechnet. Leiter und Kontaktelement erwärmen sich kontinuierlich, wobei die mittlere Endübertemperatur im Kontaktelement aufgrund des kleineren stromtragenden Querschnitts eine Größenordnung höher ist. Die Kontakte führen bei 50 Hz-Wechselstrom aufgrund ihrer vernachlässigbaren Wärmekapazität 100 Hz-Temperaturzyklen aus. Dabei können die Maximaltemperaturen noch deutlich größer als die mittlere Temperatur der Kontaktelemente sein. Im Langzeitversuch waren nach 16 000 h Betriebszeit bei 180 °C und regelmäßigen simulierten Steckvorgängen die Verbindungskräfte noch genügend groß, um die elektrischen Anforderungen eines neuen Kontaktsystems zu erfüllen. Allerdings führte bei einer Betriebstemperatur von 105 °C ein thermisch instabiles Schmierfett zum vorzeitigen elektrischen Ausfall eines Teils der Steckverbinder.:Einleitung Hochstrom-Kontaktsysteme – Stand der Technik Theorie der Kontakte bei hoher Strombelastung Stationäres elektrisch-thermisches Betriebsverhalten Transientes elektrisch-thermisches Betriebsverhalten Langzeitverhalten Zusammenfassung Ausblick / Switchgear and devices for the power grid use high-power connectors if moving parts have to be contacted or equipment shall be easily mountable and dismountable. The electrical connection of the conductors is often realized by spring-loaded contact elements. As part of the main circuit, contact elements must carry the full operating current in the kiloampere-range for the entire service life of the device. In case of a fault, the short-circuit current, which is one order of magnitude larger, has to be carried for up to several seconds. In this thesis, calculation models for the inner temperature rise of high-power contact systems in steady-state continuous operation, as well as for the transient short-circuit load case were developed. Electrical and mechanical long-term performance in the temperature range from 105 to 180 °C was experimentally investigated with current carrying, grease-lubricated model connectors which were regularly unplugged and replugged. Modelling, calculations and experiments were exemplarily carried out with Multilam contact elements. Conductors and contact element consisted of silver-plated copper. The analytical voltage-temperature relation was used to calculate the steady-state performance; calculations were verified with a temperature-rise test. The temperature difference from contact element to conductors is very small (≤ 3 K) for standard applications like switchgear. Thus, it is sufficient to use the conductor temperature as a criterion for the design of the continuous ampacity of high-power contact systems. At short-time load, a fast spatially inhomogeneous temperature rise was numerically calculated. Conductor and contact element continuously heat up; due to the smaller current carrying cross section, median final temperature rise in the contact element is one order of magnitude larger than in the conductors. Because of their negligible thermal capacity, contacts perform 100 Hz temperature cycles at 50 Hz AC load; the maximum contact temperatures may be significantly higher than the median temperature of the contact elements. In the long-term test, after 16 000 h operating time at 180 °C and regular plugging operations, contact elements maintained enough joint force to meet the requirements of a new contact system. At 105 °C however, a thermally instable grease led to electrical failure of part of the connectors.:Einleitung Hochstrom-Kontaktsysteme – Stand der Technik Theorie der Kontakte bei hoher Strombelastung Stationäres elektrisch-thermisches Betriebsverhalten Transientes elektrisch-thermisches Betriebsverhalten Langzeitverhalten Zusammenfassung Ausblick
47

Zum elektrischen Kontakt- und Langzeitverhalten von Pressverbindungen mit konventionellen und Hochtemperatur-Leiterseilen mit geringem Durchhang

Hildmann, Christian 09 December 2016 (has links)
In Deutschland und Europa ist im Zuge der Energiewende erforderlich, mehr Elektroenergie mit bestehenden Freileitungen zu transportieren. Eine technische Lösung, mit der dieses Ziel erreicht werden kann, ist das Umbeseilen der Freileitung mit Hochtemperatur-Leiterseilen mit geringem Durchhang (High Temperature Low Sag – HTLS conductors). Diese Leiterseile haben gegenüber konventionellen Leiterseilen (z. B. Aluminium/Stahl-Leiterseilen) höhere Bemessungsströme und temperaturen. Die stromführenden Verbindungen mit HTLS-Leiterseilen werden damit ebenfalls höher thermisch belastet. Diese sind für den zuverlässigen und sicheren Betrieb der Freileitung sehr wichtige Betriebsmittel. Neben anderen Verbindungstechnologien hat sich bei den stromführenden Verbindungen mit konventionellen Leiterseilen das Sechskantpressen seit Jahrzehnten bewährt. Aus der Literatur sind fast ausschließlich empirische Untersuchungen mit dieser Verbindungstechnologie bekannt. Das elektrische Kontaktverhalten von Pressverbindungen wurde bisher nur unzureichend untersucht. In dieser Arbeit wird dazu ein elektrisches Modell vorgestellt und weiterentwickelt, mit dem das elektrische Kontaktverhalten von Pressverbindungen genauer beschrieben werden kann. Weiterhin werden prinzipielle Zusammenhänge zwischen der Stromverteilung in den Kontaktpartnern und deren Einfluss auf den Verbindungswiderstand dargestellt. Als Ergebnis von theoretischen und experimentellen Untersuchungen konnten allgemeine Empfehlungen für das Dimensionieren von Pressverbindungen mit konventionellen und HTLS-Leiterseilen erarbeitet werden. Aus der prinzipiellen Funktionsweise einer Pressverbindung ist bekannt, dass der Form-, der Kraft- und der Stoffschluss in der Verbindung das elektrische Kontaktverhalten beeinflussen. Insbesondere der Kraftschluss wurde in der Literatur bislang nur näherungsweise berechnet. In den bekannten analytischen Modellen werden die Geometrie der Kontaktpartner sowie das Werkstoffverhalten vereinfacht und die mechanischen Belastungen beim Fügen der Verbindung nicht genau genug berücksichtigt. Aus den genannten Gründen wurde das Fügen von Pressverbindungen mit mehrdrähtigen Leiterseilen mit der Finite-Elemente-Methode (FEM) berechnet. Die Press- und Kontaktkräfte konnten damit für alle Kontaktflächen in einer Verbindung ermittelt werden. Es konnte gezeigt werden, dass insbesondere hohe Press- und Kontaktkräfte die Ursache für ein gutes elektrisches Kontaktverhalten einer Pressverbindung sind. Die physikalischen Ursachen dieses Zusammenhangs werden diskutiert. Das Langzeitverhalten von Pressverbindungen mit Verbund-Leiterseilen wurde experimentell untersucht. Die Ergebnisse der durchgeführten Langzeitversuche zeigen den Einfluss der Kontaktkraft im elektrischen Langzeitverhalten qualitativ auf. Bei den Pressverbindungen, für die nur sehr geringe Kontaktkräfte berechnet wurden, war das elektrische Langzeitverhalten weniger stabil. / In Germany and in Europe it is due to the “Energiewende” necessary to transmit more electrical ener-gy with existing overhead transmission lines. One possible technical solution to reach this aim is the use of high temperature low sag conductors (HTLS-conductors). Compared to the common Aluminium Conductor Steel Reinforced (ACSR), HTLS-conductors have higher rated currents and rated tempera-tures. Thus the electrical connections for HTLS-conductors are stressed to higher temperatures too. These components are most important for the safe and reliable operation of an overhead transmission line. Besides other connection technologies, hexagonal compression connections with ordinary transmis-sion line conductors have proven themselves since decades. From the literature, mostly empirical stud-ies with electrical tests for compression connections are known. The electrical contact behaviour, i.e. the quality of the electrical contact after assembly, of these connections has been investigated insuffi-ciently. This work presents and enhances an electrical model of compression connections, so that the electrical contact behaviour can be determined more accurate. Based on this, principal considerations on the current distribution in the compression connection and its influence on the connection re-sistance are presented. As a result from the theoretical and the experimental work, recommendations for the design of hexagonal compression connections for transmission line conductors were devel-oped. Furthermore it is known from the functional principle of compression type connections, that the elec-trical contact behaviour can be influenced from their form fit, force fit and cold welding. In particular the forces in compression connections have been calculated up to now by approximation. The known ana-lytical calculations simplify the geometry and material behaviour and do not consider the correct me-chanical load during assembly. For these reasons the joining process of hexagonal compression con-nections with stranded overhead transmission line conductors was calculated with the finite element method. The compression forces and the residual contact forces were determined for all contacts be-tween barrel and conductor as well as between the wires of the conductor. It was shown, that high compression and residual contact forces are the main cause of good electrical contact behaviour. The physical relations are discussed. The electrical long-term behaviour was furthermore investigated in experiments. The results confirm the influence of the residual contact force on the long-term behaviour qualitatively. Those compression connections, which had only small residual contact forces, were less stable in the long-term tests.
48

Textile Betonbewehrungen auf Basis der Multiaxial-Kettenwirktechnik

Cherif, Chokri, Hausding, Jan, Berger, Ulrike, Younes, Ayham, Kleicke, Roland January 2011 (has links)
Dieser Beitrag bietet einen Überblick über die in zwölf Jahren Forschungsarbeit am Institut für Textilmaschinen und Textile Hochleistungswerkstofftechnik (ITM) erzielten Ergebnisse auf dem Gebiet textiler Betonbewehrungen unter Einsatz der Nähwirktechnik. Standen zunächst die Weiterentwicklung der Nähwirk- bzw. Multiaxial-Kettenwirktechnik und die Integration zusätzlicher Prozessschritte im Mittelpunkt, so wurde dies mit der Einführung neuer Faserwerkstoffe durch die Beantwortung grundlegender Fragen zum Materialverhalten von Glas- und Carbonfasern unter verschiedensten Belastungsszenarien ergänzt. Aufbauend auf den gewonnen Erkenntnissen stehen heute Multiaxialgelege als Bewehrung für Beton zur Verfügung, die ein weites Anforderungsspektrum abdecken können, mit hoher Qualität und Produktivität herstellbar sind und damit den praktischen Einsatz des Textilbetons auf breiter Basis ermöglichen. / This paper provides an overview on the results of textile concrete achieved in twelve years of research at the Institute of Textile Machinery and High Performance Material Technology (ITM) in the field of textile reinforcements for concrete based on the multiaxial stitch-bonding technology. During the early years the research focused on the development of the textile manufacturing process and the integration of additional functions in stitch-bonding machines. With the introduction of new fiber materials this was shifted towards the description of the material behavior of glass and carbon fibers under different load scenarios. Based on the results of this research, multiaxial multi-ply fabrics are available now as reinforcements for concrete, covering a broad range of applications. These fabrics can be produced with high quality and productivity and enable the practical usage of textile reinforced concrete.
49

Prognose des Langzeitverhaltens von Textilbeton-Tragwerken mit rekurrenten neuronalen Netzen

Freitag, Steffen, Graf, Wolfgang, Kaliske, Michael 03 June 2009 (has links)
Zur Prognose des Langzeitverhaltens textilbetonverstärkter Tragwerke wird ein modellfreies Vorgehen auf Basis rekurrenter neuronaler Netze vorgestellt. Das Vorgehen ermöglicht die Prognose zeitveränderlicher Strukturantworten unter Berücksichtigung der gesamten Belastungsgeschichte. Mit unscharfen Größen aus Messungen an Versuchstragwerken werden rekurrente neuronale Netze trainiert. Anschließend ist die unscharfe Prognose des Tragverhaltens möglich.
50

Investigation on the heat extraction performance of deep closed-loop borehole heat exchanger system for building heating

Chen, Chaofan 03 June 2022 (has links)
In recent years, deep geothermal energy has been widely exploited through closed-loop borehole heat exchanger system for building heating. In order to precisely evaluate the sustainable heat extraction capacity and the impact of different designs and operating parameters, two heat transfer models are implemented in the open-source scientific software OpenGeoSys (OGS), with respect to the Deep Borehole Heat Exchanger (DBHE) and Enhanced U-tube Borehole Heat Exchanger (EUBHE) system. Besides, three types of boundary conditions are implemented, including the constant inflow temperature, the constant heat extraction rate, and constant building thermal power that integrates the ground source heat pump (GSHP) module. By applying the two BHE models, the influence of different designs and operating parameters on the GSHP system is evaluated. The sustainable heat extraction capacity and efficiency of a deep EUBHE system are predicted. Moreover, its performance and efficiency are further compared against the 2-DBHE array system that has the same total borehole length. It is found that the soil thermal conductivity is the most important parameter in the design of DBHE and EUBHE systems. The sustainable specific heat extraction rate of the EUBHE system is 86.5 W/m higher than an array with 2 DBHEs. Under the building thermal load of 1.225 MW, the total electricity consumed by the EUBHE system is approximately 27 % less than the 2-DBHE array over 10 years. The average Coefficient of System Performance (CSP) value of the EUBHE system is 1.66 higher over 10 heating seasons. The two numerical models implemented in the OpenGeoSys software can be used to predict and optimize the thermal characteristics of the closed-loop DBHE and EUBHE systems in real projects.