• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 3
  • 1
  • 1
  • Tagged with
  • 15
  • 15
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do laser Nd:YAG na qualidade da hibridização da dentina bovina empregando sistema adesivo convencional ou autocondicionante: análise em MEV

Kuwana , Andressa da Silva [UNESP] 23 June 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-06-23Bitstream added on 2014-06-13T19:01:39Z : No. of bitstreams: 1 kuwana_as_dr_sjc.pdf: 2949815 bytes, checksum: 9e2579e94e33824b702cad531113e505 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desta pesquisa foi avaliar em MEV a influência da irradiação com laser Nd:YAG na qualidade da hibridização da dentina bovina, empregando-se sistema adesivo convencional Adper Single Bond – 3M ESPE (SB) ou autocondicionante Clearfil SE Bond – Kuraray (CSEB). Para tanto, foram utilizados 12 incisivos bovinos, extraídos e congelados. Os dentes foram seccionados em duas hemicoroas e incluídos em resina acrílica. Em seguida, a superfície vestibular foi desgastada até a obtenção da dentina de profundidade média. Cada hemi-coroa do mesmo dente, foi submetida em sua porção incisal ao SB e em sua porção cervical ao CSEB, sendo divididas em 3 grupos, de 6 hemi-coroas cada: Controle - após a aplicação dos sistemas adesivos foi realizada a fotopolimerização ; G1 – após a aplicação dos sistemas adesivos a amostra foi irradiada com laser Nd:YAG com 60mJ de energia/pulso previamente à fotopolimerização e G2 – após a aplicação dos sistemas adesivos a amostra foi irradiada com laser Nd:YAG com 140mJ de energia/pulso previamente à fotopolimerização. Todas as amostras receberam a aplicação de dois incrementos de resina composta Filtek Z350 – 3M ESPE e fotopolimerização de acordo com as orientações do fabricante. Após 24h de armazenagem em água destilada a 37ºC, os perfis de adesão foram polidos, submetidos a um desafio ácido-base, e processados para análise em MEV da espessura da camada híbrida, presença de falhas e de tags e microtags. Foram obtidas quatro medidas e a média para cada amostra. Os resultados foram submetidos aos testes estatísticos de Análise de Variância (ANOVA) e de Tukey (p<0,05), segundo os quais, independente do sistema adesivo o G2 apresentou a maior média de espessura da camada híbrida (1,89±0,15) e o Controle com o Clearfil SE Bond apresentou a menor média de espessura de camada híbrida, diferindo... / The aim of this study was to assess through analyses in scanning electronic microscopy (SEM), the Nd:YAG laser influence on the hybridization quality of bovine dentine, using conventional adhesive system Adper Single Bond - 3M ESPE (SB) or self-etching adhesive system - Clearfil SE Bond - Kuraray (CSEB). Twelve extracted and frozen bovine incisors were used. The teeth were sectioned and divided in half mesio-distal section built-in acrylic resin. The buccal dentinal surface was worn out until the dentin medium depth was reached. Each specimen of the same tooth was treated on its incisal portion with SB and with CSEB in its cervical portion. The samples were divided into 3 groups with 6 specimens in each: Control group - after the application of the adhesive systems the polymerization was done; G1 - after the application of the adhesive systems the samples were lased with 60mJ /pulse and polymerized and G2 - after the application of the adhesive systems the samples were lased with with 140mJ /pulse and also polymerized. All the samples received the composite resin (Filtek Z350 - 3M ESPE) increments. After 24h storage in distilled water at 37ºC, the adhesion profiles were polished, submitted to the acid-base challenge, and the presence of imperfections and tags or microtags in the hybrid layer analysed using the SEM. Four measures and the mean value of each sample were obtained. The results were submitted to Analysis of Variance (ANOVA) and Tukey statistical tests (p 0,05). Independent of the adhesive system used the G2 presented the higher average of hybrid layer thickness (1,89±0,15) and the Control group with the Clearfil SE Bond presented the smaller hybrid layer thickness presenting significant statistical difference from the other groups. Different scores were attributed for the degree of imperfections (0-3) and for the degree of presence of tags and microtags (0-2)... (Complete abstract, click electronic access below)
2

Estudo das propriedades mecânicas da interface adesiva criada por sistemas adesivos convencional e autocondicionante, associados ou não ao laser Nd:YAG, utilizando a técnica da nanoindentação

Silva, Patrícia Rondon Pleffken da [UNESP] 05 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-05Bitstream added on 2014-06-13T19:51:19Z : No. of bitstreams: 1 silva_prp_me_sjc.pdf: 750069 bytes, checksum: 94263aef7c378118e8087ea9d933ad86 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desta pesquisa foi avaliar a influência do laser Nd:YAG nas propriedades mecânicas (dureza e módulo de elasticidade) da interface adesiva, utilizando a técnica da nanoindentação, empregando-se sistema adesivo convencional Adper Single Bond 2 – 3M ESPE (SB) ou autocondicionante Clearfil SE Bond – Kuraray (CSE). Doze terceiros molares humanos tiveram suas superfícies oclusais desgastadas até a exposição da dentina superficial. Uma cavidade circular padronizada com fresa 3053 foi realizada na superfície oclusal proporcionando 2 mm de dentina remanescente. Os espécimes foram embutidos em resina acrílica, e seccionados no sentido mésio-distal, sendo as 24 hemi-coroas obtidas divididas em quatro grupos: Grupo controle (SBC) - aplicação do sistema SB de acordo com as recomendações do fabricante; Grupo laser (SBL) - aplicação do sistema adesivo SB e tratamento com laser Nd:YAG (140mJ/cm2/60s/não contato); Grupo controle (CSEC) - aplicação do sistema adesivo autocondicionante CSE de acordo com as recomendações do fabricante; Grupo laser (CSEL)- aplicação do sistema adesivo autocondicionante CSE e tratamento com laser Nd:YAG (140mJ/cm2/60s/não contato). Após a polimerização dos sistemas adesivos, foram aplicados dois incrementos da resina composta Filtek Z 350 (3M ESPE). Os corpos-de-prova foram imersos em água destilada e armazenados por 24h em estufa 37ºC e submetidos à nanoidentação em aparelho Nano Indenter® XP (MTS®, MN, EUA).. Os resultados foram submetidos aos testes estatísticos de Análise de Variância (ANOVA), Tukey e t-Student (p<0,05). Concluiu-se que a aplicação do laser Nd:YAG em ambos os sistemas adesivos não alterou o nível de dureza da interface adesiva, no entanto alterou o módulo de elasticidade / The aim of this study was to evaluate the influence of Nd: YAG laser on the mechanical properties (hardness and modulus of elasticity) of the adhesive interface, using the technique of nanoindentation, employing conventional adhesive system Single Bond 2 3M ESPE (SB) or selfetching adhesive system Clearfil SE Bond - Kuraray (CSE). On 12 human molars, a flat superficial dentin surface was exposed by abrasion. A standardized circular cavity with bur 3053 was performed on the occlusal surface and dentin thickness was standardized in 2 mm. The specimens were embedded in resin acrylic and sectioned mesio-distally through their long axes, and the 24 hemi-crowns obtained divided into four groups: Control Group (SBC) – the application of SB system according to the manufacturer's recommendations; Laser Group (SBL) – SB adhesive system and treatment with Nd: YAG laser (140mJ/cm2/60s/no contact) Control Group (CSEC) – application of CSE self-etching adhesive system according to the manufacturer's recommendations; Laser Group (CSEL) – application of CSE self-etching adhesive system and treatment with Nd: YAG laser (140mJ/cm2/60s/no contact). After polymerization of the adhesives, were applied two increments of composite resin Filtek Supreme and specimens were immersed in distilled water and stored for 24 hours at 37 ºC and submitted to nanoidentation in Nano Indenter ® XP (MTS ®, MN, USA. Nanoindentation were made on composite resin, adhesive system, hybrid layer and dentin. The results were analyzed by a tree-way ANOVA, Tukey and e t-Students (p<0,05). It was concluded that the application of Nd:YAG laser in both adhesive systems did not change hardness level of hybrid layer, however chanded the elastic modulus
3

Caracterização do potencial antierosivo do laser Nd:YAG e fluoretos: um estudo in vitro

Silva, Patricia Fernandes Cassimiro da 31 January 2013 (has links)
Submitted by Leonardo Freitas (leonardo.hfreitas@ufpe.br) on 2015-04-14T14:35:17Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Patricia Fernandes Cassimiro.pdf: 1701117 bytes, checksum: d5a72b1cd9462cd35a6de464d1725fac (MD5) / Made available in DSpace on 2015-04-14T14:35:17Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Patricia Fernandes Cassimiro.pdf: 1701117 bytes, checksum: d5a72b1cd9462cd35a6de464d1725fac (MD5) Previous issue date: 2013-01-31 / CAPES / O objetivo deste estudo foi avaliar o efeito preventivo do laser Nd:YAG utilizado juntamente com um verniz fluoretado na erosão e a efetividade da sua associação ao uso de um creme dental a base de fluoreto de sódio (NaF), além de avaliar o efeito inibidor de diferentes cremes dentais a base de NaF, fluoreto de estanho (SnF2) e nano complexo caseína fosfopeptídea e fosfato de cálcio amorfo (CPPACP) frente ao processo erosivo. Junto a isso, verificar se a tomografia por coerência óptica (TCO) pode ser um método quantitativo a ser utilizado para avaliação de erosão do esmalte. Superfícies de esmalte bovino foram distribuídos aleatoriamente em 6 grupos (n=7): NC – controle negativo (sem tratamento); LV – Laser Nd:YAG + verniz de NaF; LV/NaF – Laser Nd:YAG + verniz de NaF + Proesmalte (NaF); NaF – Pro-esmalte; SnF2/NaF – Pro-Saúde; CPP-ACP/NaF – MI Paste Plus. Os grupos LV e LV/NaF foram irradiados a laser Nd:YAG (10 Hz, 1W, 141,5 J/cm2) durante 30 segundos e em seguida foi aplicado verniz fluoretado (NaF) por 4 horas. A ciclagem erosiva foi realizada em solução de ácido cítrico 0,5% (pH 2,6) 5 x 3 minutos ao dia, seguido pela exposição aos cremes dentais por 2 minutos após a primeira e última ciclagem de cada dia em todos os grupos, com exceção dos grupos NC e LV. No grupo NC nenhum tratamento foi realizado. A análise quantitativa foi realizada através de perfilometria por contato e tomografia por coerência óptica, complementada pela análise qualitativa da microscopia eletrônica de varredura. Entre os métodos testados, a associação laser/verniz/pro-esmalte mostrou-se uma boa estratégia preventiva, com maior efeito redutor de perda mineral. Entre os cremes dentais, em ambos os métodos quantitativos de avaliação, o CPP-ACP/NaF foi o que apresentou o menor efeito redutor da erosão, no entanto Click to buy NOW! PDF-XChange Viewer www.docu-track.com Click to buy NOW! PDF-XChange Viewer www.docu-track.com o creme dental a base de SnF2/NaF apresentou bons resultados. Ambos os métodos de avaliação foram efetivos, não apresentando diferenças estatísticas.
4

Avaliação in vitro e in situ da eficácia de diferentes lasers no aumento da resistência ácida do esmalte em regiões de sulcos e fissuras / In vitro and in situ assessment of lasers to increase enamel acid resistance on the pits and fissures surface.

Afonso, Alessandra Marques Corrêa 03 December 2009 (has links)
O objetivo desse estudo foi avaliar in vitro e in situ a efetividade de irradiação dos lasers Er:YAG, Nd:YAG e CO2 no aumento da resistência ácida do esmalte em regiões de sulcos e fissuras. Para o estudo in vitro foram utilizados molares humanos em fragmentos da porção oclusal de 8mmx4mm divididos em 3 grupos de acordo com o tipo de tratamento : Grupo 1 - Er:YAG; Grupo 2 - Nd:YAG; Grupo 3 - CO2 (n=15). O tratamento de superfície foi feito apenas em metade da área do fragmento, sendo que a outra metade foi considerada controle. As áreas expostas ao desafio cariogênico (14mm2) foram submetidas a ciclagens de pH. Para o testede microdureza os espécimes foram seccionados ao meio e a parede da secção é que sofreu o teste, a outra metade foi utilizada para análise em microscopia de luz polarizada para a medição da área da lesão de desmineralização e análise em MEV para verificar as alterações na morfologia do tecido dentário. As análises dos dados de microdureza (HKN) e área das lesões (mm2) foram feitas com o teste de Wilcoxon para a comparação interna de cada grupo com o seu controle e a comparação entre os grupos utilizou ANOVA para as áreas das lesões e Kruskal Wallis para a microdureza (&alpha; = 5%). Foi observada apenas diferença estatística significante para as amostras do grupo irradiado com laser CO2 entre as partes controle e experimental. Os demais grupos não apresentaram diferença estatisticamente significante com sua área controle. Na análise das medidas de lesão foram observadas diferença estatística significante para as amostras do grupo irradiado com os lasers CO2 e Nd:YAG com suas partes controles, sendo as medidas de área de lesão apresentadas pela área irradiada inferiores a área controle. Na análise em MEV o grupo irradiado com laser CO2 mostrou ausência de exposição dos prismas de esmalte e modificação de superfície na área irradiada. Para o estudo in situ foram utilizados molares humanos em fragmentos da porção oclusal de 4mmx4mm tratados com os 3 diferentes tipos de laser: Grupo 1 - controle (sem tratamento); Grupo 2 - Er:YAG; Grupo 3 - Nd:YAG; Grupo 4 - CO2 (n=15). Os espécimes foram adaptados a um dispositivo intrabucal que foi utilizado pelos voluntários durante 14 dias. Para o desafio cariogênico gotejou-se solução de sacarose 20% sobre os espécimes. Assim como no estudo in vitro, foram realizados o teste de microdureza, análise em microscópio de luz polarizada e análise em MEV. Para a análise dos dados de microdureza (HKN) foi utilizada ANOVA e teste de Fisher LSD (&alpha;= 5%). Foi observada diferença estatística significante para as amostras do grupo irradiado com laser CO2 e Nd:YAG, que apresentaram maiores valores de microdureza do que o grupo controle e não foram diferentes estatisticamente entre si. Os valores de microdureza observados em profundidade foram maiores proporcionalmente a distância da superfície, ou seja, 20&micro;m <30&micro;m <40&micro;m <50&micro;m. Na análise em microscopia de luz polarizada a análise foi feita com teste de Wilcoxon e todos os grupos apresentaram semelhança estatística. Considerando os resultados obtidos nos dois estudo pode-se concluir que os lasers CO2 e Nd:YAG foram capazes de promover aumento de resistência ácida no esmalte dental localizado nas superfície de sulcos e fissuras. / The aim of this study was to assess in vitro and in situ the lasers Er:YAG, Nd:YAG e CO2 in preventing enamel demineralization on the pits and fissures surface. For the in vitro study 45 occlusal enamel blocks were randomly divided into 3 groups in according with the treatment: G1 - Er:YAG; G2 - Nd:YAG; G3 - CO2. Treatments were made only on a half of the specimen and the remaining part was considered as a control. The samples were submitted to an in vitro pH cycles. For the microhardness test the specimens were seccioned in the middle and the seccioned wall received the test. The other halves were analyzed using polarized light microscopy for the measurement of the caries-lesion areas and morphological SEM analyses. Wilcoxon test were performed for the statistical analysis of the data obtained from the microhardness test (KHN) and caries-lesion area measurements (mm2) (&alpha;= 5%) when each groups was compared with its control. Variance analysis were performed for the difference in means of microhardness data and Kruskal Wallis test were performed for the difference in means of caries-lesion area measurements (&alpha;= 5%). For the microhardness data the G3 was statically different from its control area and the others groups presented statistical similarity among the experimental and control areas. For the caries-lesion area measurements statistical difference was observed for the groups G2 and G3 presenting smaller caries-lesion area when compared with their respective control areas. In the SEM analysis the G3 showed uniform surface without enamel-prism exposure. For the in situ study 60 occlusal enamel blocks were randomly divided into 4 groups in according with the treatment: G1 - Control (no treatment); G2 - Er:YAG; G3 - Nd:YAG; G4 - CO2 (n=15). The specimens were fixed in intra oral appliances and worn by the volunteers for 14d. Sucrose solution (20%) was applied to each specimen 6 times/d. As the in vitro study the samples were removed, sectioned and examined for microhardness, caries-lesion area measurements on the polarized light microcopy and morphological analyses on SEM. Variance analysis and the Fisher test were performed for the statistical analysis of the data obtained from the microhardness test (KHN) (&alpha;= 5%). The control group was statically different from G3 and G4, which present higher microhardness values and were statistical similar between them. The data of microhardness from the depth of surface were greater in proportion of distance from the surface, as 20&micro;m <30&micro;m <40&micro;m <50&micro;m. Wilcoxon test were performed for the statistical analysis of the data obtained from the caries-lesion area measurements (mm2) (= 5%) and all the groups were statically similar. Considering the results obtained from the both of studies can be concluded that the laser CO2 and Nd:YAG were able to increase the enamel acid resistance on the surface of pits and fissures.
5

Avaliação in vitro e in situ da eficácia de diferentes lasers no aumento da resistência ácida do esmalte em regiões de sulcos e fissuras / In vitro and in situ assessment of lasers to increase enamel acid resistance on the pits and fissures surface.

Alessandra Marques Corrêa Afonso 03 December 2009 (has links)
O objetivo desse estudo foi avaliar in vitro e in situ a efetividade de irradiação dos lasers Er:YAG, Nd:YAG e CO2 no aumento da resistência ácida do esmalte em regiões de sulcos e fissuras. Para o estudo in vitro foram utilizados molares humanos em fragmentos da porção oclusal de 8mmx4mm divididos em 3 grupos de acordo com o tipo de tratamento : Grupo 1 - Er:YAG; Grupo 2 - Nd:YAG; Grupo 3 - CO2 (n=15). O tratamento de superfície foi feito apenas em metade da área do fragmento, sendo que a outra metade foi considerada controle. As áreas expostas ao desafio cariogênico (14mm2) foram submetidas a ciclagens de pH. Para o testede microdureza os espécimes foram seccionados ao meio e a parede da secção é que sofreu o teste, a outra metade foi utilizada para análise em microscopia de luz polarizada para a medição da área da lesão de desmineralização e análise em MEV para verificar as alterações na morfologia do tecido dentário. As análises dos dados de microdureza (HKN) e área das lesões (mm2) foram feitas com o teste de Wilcoxon para a comparação interna de cada grupo com o seu controle e a comparação entre os grupos utilizou ANOVA para as áreas das lesões e Kruskal Wallis para a microdureza (&alpha; = 5%). Foi observada apenas diferença estatística significante para as amostras do grupo irradiado com laser CO2 entre as partes controle e experimental. Os demais grupos não apresentaram diferença estatisticamente significante com sua área controle. Na análise das medidas de lesão foram observadas diferença estatística significante para as amostras do grupo irradiado com os lasers CO2 e Nd:YAG com suas partes controles, sendo as medidas de área de lesão apresentadas pela área irradiada inferiores a área controle. Na análise em MEV o grupo irradiado com laser CO2 mostrou ausência de exposição dos prismas de esmalte e modificação de superfície na área irradiada. Para o estudo in situ foram utilizados molares humanos em fragmentos da porção oclusal de 4mmx4mm tratados com os 3 diferentes tipos de laser: Grupo 1 - controle (sem tratamento); Grupo 2 - Er:YAG; Grupo 3 - Nd:YAG; Grupo 4 - CO2 (n=15). Os espécimes foram adaptados a um dispositivo intrabucal que foi utilizado pelos voluntários durante 14 dias. Para o desafio cariogênico gotejou-se solução de sacarose 20% sobre os espécimes. Assim como no estudo in vitro, foram realizados o teste de microdureza, análise em microscópio de luz polarizada e análise em MEV. Para a análise dos dados de microdureza (HKN) foi utilizada ANOVA e teste de Fisher LSD (&alpha;= 5%). Foi observada diferença estatística significante para as amostras do grupo irradiado com laser CO2 e Nd:YAG, que apresentaram maiores valores de microdureza do que o grupo controle e não foram diferentes estatisticamente entre si. Os valores de microdureza observados em profundidade foram maiores proporcionalmente a distância da superfície, ou seja, 20&micro;m <30&micro;m <40&micro;m <50&micro;m. Na análise em microscopia de luz polarizada a análise foi feita com teste de Wilcoxon e todos os grupos apresentaram semelhança estatística. Considerando os resultados obtidos nos dois estudo pode-se concluir que os lasers CO2 e Nd:YAG foram capazes de promover aumento de resistência ácida no esmalte dental localizado nas superfície de sulcos e fissuras. / The aim of this study was to assess in vitro and in situ the lasers Er:YAG, Nd:YAG e CO2 in preventing enamel demineralization on the pits and fissures surface. For the in vitro study 45 occlusal enamel blocks were randomly divided into 3 groups in according with the treatment: G1 - Er:YAG; G2 - Nd:YAG; G3 - CO2. Treatments were made only on a half of the specimen and the remaining part was considered as a control. The samples were submitted to an in vitro pH cycles. For the microhardness test the specimens were seccioned in the middle and the seccioned wall received the test. The other halves were analyzed using polarized light microscopy for the measurement of the caries-lesion areas and morphological SEM analyses. Wilcoxon test were performed for the statistical analysis of the data obtained from the microhardness test (KHN) and caries-lesion area measurements (mm2) (&alpha;= 5%) when each groups was compared with its control. Variance analysis were performed for the difference in means of microhardness data and Kruskal Wallis test were performed for the difference in means of caries-lesion area measurements (&alpha;= 5%). For the microhardness data the G3 was statically different from its control area and the others groups presented statistical similarity among the experimental and control areas. For the caries-lesion area measurements statistical difference was observed for the groups G2 and G3 presenting smaller caries-lesion area when compared with their respective control areas. In the SEM analysis the G3 showed uniform surface without enamel-prism exposure. For the in situ study 60 occlusal enamel blocks were randomly divided into 4 groups in according with the treatment: G1 - Control (no treatment); G2 - Er:YAG; G3 - Nd:YAG; G4 - CO2 (n=15). The specimens were fixed in intra oral appliances and worn by the volunteers for 14d. Sucrose solution (20%) was applied to each specimen 6 times/d. As the in vitro study the samples were removed, sectioned and examined for microhardness, caries-lesion area measurements on the polarized light microcopy and morphological analyses on SEM. Variance analysis and the Fisher test were performed for the statistical analysis of the data obtained from the microhardness test (KHN) (&alpha;= 5%). The control group was statically different from G3 and G4, which present higher microhardness values and were statistical similar between them. The data of microhardness from the depth of surface were greater in proportion of distance from the surface, as 20&micro;m <30&micro;m <40&micro;m <50&micro;m. Wilcoxon test were performed for the statistical analysis of the data obtained from the caries-lesion area measurements (mm2) (= 5%) and all the groups were statically similar. Considering the results obtained from the both of studies can be concluded that the laser CO2 and Nd:YAG were able to increase the enamel acid resistance on the surface of pits and fissures.
6

Avaliação in vitro da resistência ácida e da permeabilidade do esmalte dental decíduo irradiado com laser Nd:Yag associado ou não ao flúor / Analysis in vitro of acid resistance and permeability of primary tooth enamel after Nd:YAG laser irradiation, associated or not with fluoride

Azevedo, Danielle Torres 03 June 2011 (has links)
A eficiência dos lasers associado ou não a fluoretos no aumento da resistência ácida e na redução da solubilidade do esmalte dentário tem sido confirmada em diversos estudos. Diversos comprimentos de onda têm sido utilizados com esta finalidade, apresentando bons resultados e representando uma abordagem preventiva simples e não invasiva. Apesar do emprego do laser Nd:YAG ter sua ação preventiva bem conhecida, são escassos os estudos em dentes decíduos, principalmente estudos que estabeleçam parâmetros seguros e eficientes, seja associado ao flúor ou isoladamente. Desta forma, o objetivo do presente estudo foi avaliar a resistência ácida e a permeabilidade do esmalte decíduo. Para tanto, foram selecionados 69 molares decíduos humanos, resultando em 132 corpos-de-prova. As variáveis de resposta quantitativa foram a microdureza longitudinal, profundidade da desmineralização e permeabilidade do esmalte, e as variáveis de resposta qualitativa foram morfologia da superfície, presença de íons flúor e análise dos componentes químicos do esmalte. Foram utilizados 60 fragmentos vestibular/lingual para a análise de resistência ácida e midrodureza (n=10), e após preparados e tratados, estes espécimes foram submetidos ao ciclo de desremineralização para formação de lesão de cárie artificial. Para análise da permeabilidade (48 fragmentos n=8), para a análise de MEV e EDX (18 fragmentos n=3) e para DRX (6 dentes n=1) foi realizado apenas o tratamento da superfície em 6 níveis: C- Controle: sem tratamento; FA: aplicação de gel flúor fosfato acidulado 1,23%; FAL: aplicação de gel flúor fosfato acidulado + Laser Nd:YAG 0,5W/10Hz no modo contato; VF: aplicação de verniz fluoretado 5%; VFL: aplicação de verniz fluoretado 5% + Laser Nd:YAG; L: aplicação do Laser Nd:YAG. Os dados de microdureza (%VM) foram avaliados pelo teste de Kruskal-Wallis e os dados de profundidade da desmineralização (PD) e Permeabilidade (P) foram avaliados pelos testes ANOVA e Fisher&prime;s LSD (&alpha;=5% para todos os testes). Observou-se que os grupos FAL e FA apresentaram a menor variação de dureza em relação aos outros grupos; menor extensão de desmineralização foi observada nos grupos FA, FAL, VF, VFL e L e menor permeabilidade foi verificada nos grupos FA, FAL, VF, VFL e L em relação ao grupo controle (C). Na MEV observouse ausência de fissuras, crateras ou qualquer alteração indesejável na superfície. Na EDX observou-se incorporação de flúor em todos os grupos experimentais (FA, FAL, VF, VFL), exceto no grupo laser (L). Nenhum composto novo foi encontrado na análise de DRX após a associação do flúor com o laser. O laser utilizado isoladamente ou associado ao flúor levou a alterações ultra-estruturais na superfície do esmalte, o que pode ter sido responsável pelo aumento da resistência ácida e redução da permeabilidade, indicando que o laser isoladamente ou associado ao flúor, nas condições desta pesquisa, foi capaz de inibir a desmineralização do esmalte dental decíduo. / The efficiency of lasers associated or not with fluorides, in increasing the acid resistance and decrease of enamel solubility of dental enamel has been confirmed by several studies. Several wavelengths have been used for such purpose, providing good results and representing a simple and non-invasive preventive approach. Although the preventive action of Nd:YAG laser is well known, studies on primary teeth are scarce, especially those that establish safe and efficient parameters, when the laser is either associated with fluoride or used alone. Therefore, the aim of this study was to evaluate the acid resistance and permeability of primary tooth enamel. Sixty-nine human primary molars were used, providing 132 specimens. The quantitative response variables were enamel longitudinal microhardness, demineralization depth and permeability, while the qualitative response variables were surface morphology, presence of fluoride ions and analysis of the chemical components of enamel. Sixty buccal/lingual fragments were used for analysis of acid resistance and microhardness (n=10). After being prepared and treated, thee specimens were subjected to a des-remineralization cycle for artificial caries lesion formation. For analysis of permeability (48 fragments, n=8), SEM and EDX (18 fragments, n=3) and DRX (6 teeth, n=1), only surface treatment was performed in 6 levels: C- Control: no treatment; APF: application of 1.23% acidulated phosphate fluoride gel; APFL: application of 1.23% acidulated phosphate fluoride gel + Nd:YAG laser 0.5W/10Hz in mode contact; FV: application of 5% fluoride varnish; FVL: application of 5%fluoride varnish + Nd:YAG laser; L: application of Nd:YAG laser. Microhardness data (%VM) were analyzed by the Kruskal-Wallis test and demineralization depth (DD) and permeability (P) were analyzed by ANOVA and Fisher&prime;s LSD test (&alpha;=5% for all tests). APFL and APF presented the lowest microhardness variation of all groups; lower extension of demineralization was observed in groups APF, APFL, FV, FVL and L, and lower permeability was observed in groups APF, APFL, FV, FVL and L compared to group C. The SEM analysis revealed absence of fissures, craters or any other undesirable surface alteration. The EDX analysis revealed fluoride incorporation in all experimental groups (APF, APFL, FV, FVL), except for the group L. No new compound was found in the DRX analysis when fluoride was associated with the laser. Laser alone or associated with fluoride produced ultrastructural alterations on enamel surface, which might have caused the increase of acid resistance and decrease of permeability, thus indicating that, under the conditions of this study, the Nd:YAG laser used alone or associated with fluoride was capable of inhibiting the demineralization of primary tooth enamel.
7

Avaliação in vitro da resistência ácida e da permeabilidade do esmalte dental decíduo irradiado com laser Nd:Yag associado ou não ao flúor / Analysis in vitro of acid resistance and permeability of primary tooth enamel after Nd:YAG laser irradiation, associated or not with fluoride

Danielle Torres Azevedo 03 June 2011 (has links)
A eficiência dos lasers associado ou não a fluoretos no aumento da resistência ácida e na redução da solubilidade do esmalte dentário tem sido confirmada em diversos estudos. Diversos comprimentos de onda têm sido utilizados com esta finalidade, apresentando bons resultados e representando uma abordagem preventiva simples e não invasiva. Apesar do emprego do laser Nd:YAG ter sua ação preventiva bem conhecida, são escassos os estudos em dentes decíduos, principalmente estudos que estabeleçam parâmetros seguros e eficientes, seja associado ao flúor ou isoladamente. Desta forma, o objetivo do presente estudo foi avaliar a resistência ácida e a permeabilidade do esmalte decíduo. Para tanto, foram selecionados 69 molares decíduos humanos, resultando em 132 corpos-de-prova. As variáveis de resposta quantitativa foram a microdureza longitudinal, profundidade da desmineralização e permeabilidade do esmalte, e as variáveis de resposta qualitativa foram morfologia da superfície, presença de íons flúor e análise dos componentes químicos do esmalte. Foram utilizados 60 fragmentos vestibular/lingual para a análise de resistência ácida e midrodureza (n=10), e após preparados e tratados, estes espécimes foram submetidos ao ciclo de desremineralização para formação de lesão de cárie artificial. Para análise da permeabilidade (48 fragmentos n=8), para a análise de MEV e EDX (18 fragmentos n=3) e para DRX (6 dentes n=1) foi realizado apenas o tratamento da superfície em 6 níveis: C- Controle: sem tratamento; FA: aplicação de gel flúor fosfato acidulado 1,23%; FAL: aplicação de gel flúor fosfato acidulado + Laser Nd:YAG 0,5W/10Hz no modo contato; VF: aplicação de verniz fluoretado 5%; VFL: aplicação de verniz fluoretado 5% + Laser Nd:YAG; L: aplicação do Laser Nd:YAG. Os dados de microdureza (%VM) foram avaliados pelo teste de Kruskal-Wallis e os dados de profundidade da desmineralização (PD) e Permeabilidade (P) foram avaliados pelos testes ANOVA e Fisher&prime;s LSD (&alpha;=5% para todos os testes). Observou-se que os grupos FAL e FA apresentaram a menor variação de dureza em relação aos outros grupos; menor extensão de desmineralização foi observada nos grupos FA, FAL, VF, VFL e L e menor permeabilidade foi verificada nos grupos FA, FAL, VF, VFL e L em relação ao grupo controle (C). Na MEV observouse ausência de fissuras, crateras ou qualquer alteração indesejável na superfície. Na EDX observou-se incorporação de flúor em todos os grupos experimentais (FA, FAL, VF, VFL), exceto no grupo laser (L). Nenhum composto novo foi encontrado na análise de DRX após a associação do flúor com o laser. O laser utilizado isoladamente ou associado ao flúor levou a alterações ultra-estruturais na superfície do esmalte, o que pode ter sido responsável pelo aumento da resistência ácida e redução da permeabilidade, indicando que o laser isoladamente ou associado ao flúor, nas condições desta pesquisa, foi capaz de inibir a desmineralização do esmalte dental decíduo. / The efficiency of lasers associated or not with fluorides, in increasing the acid resistance and decrease of enamel solubility of dental enamel has been confirmed by several studies. Several wavelengths have been used for such purpose, providing good results and representing a simple and non-invasive preventive approach. Although the preventive action of Nd:YAG laser is well known, studies on primary teeth are scarce, especially those that establish safe and efficient parameters, when the laser is either associated with fluoride or used alone. Therefore, the aim of this study was to evaluate the acid resistance and permeability of primary tooth enamel. Sixty-nine human primary molars were used, providing 132 specimens. The quantitative response variables were enamel longitudinal microhardness, demineralization depth and permeability, while the qualitative response variables were surface morphology, presence of fluoride ions and analysis of the chemical components of enamel. Sixty buccal/lingual fragments were used for analysis of acid resistance and microhardness (n=10). After being prepared and treated, thee specimens were subjected to a des-remineralization cycle for artificial caries lesion formation. For analysis of permeability (48 fragments, n=8), SEM and EDX (18 fragments, n=3) and DRX (6 teeth, n=1), only surface treatment was performed in 6 levels: C- Control: no treatment; APF: application of 1.23% acidulated phosphate fluoride gel; APFL: application of 1.23% acidulated phosphate fluoride gel + Nd:YAG laser 0.5W/10Hz in mode contact; FV: application of 5% fluoride varnish; FVL: application of 5%fluoride varnish + Nd:YAG laser; L: application of Nd:YAG laser. Microhardness data (%VM) were analyzed by the Kruskal-Wallis test and demineralization depth (DD) and permeability (P) were analyzed by ANOVA and Fisher&prime;s LSD test (&alpha;=5% for all tests). APFL and APF presented the lowest microhardness variation of all groups; lower extension of demineralization was observed in groups APF, APFL, FV, FVL and L, and lower permeability was observed in groups APF, APFL, FV, FVL and L compared to group C. The SEM analysis revealed absence of fissures, craters or any other undesirable surface alteration. The EDX analysis revealed fluoride incorporation in all experimental groups (APF, APFL, FV, FVL), except for the group L. No new compound was found in the DRX analysis when fluoride was associated with the laser. Laser alone or associated with fluoride produced ultrastructural alterations on enamel surface, which might have caused the increase of acid resistance and decrease of permeability, thus indicating that, under the conditions of this study, the Nd:YAG laser used alone or associated with fluoride was capable of inhibiting the demineralization of primary tooth enamel.
8

Soldagem de lâminas finas da liga de titânio Ti6Al4V com laser Nd:YAG pulsado /

Alves, Bruno Crepaldi. January 2019 (has links)
Orientador: Vicente Afonso Ventrella / Resumo: O presente trabalho estudou o processo de soldagem laser Nd:YAG pulsado aplicado em lâminas finas da liga de titânio Ti-6Al-4V, utilizado no revestimento de sensores que trabalham em ambiente corrosivo da indústria sucroalcooleira, química, petroquímica e alimentícia. Variou-se a energia de pulso de 1,0 J a 2,00 J, com incrementos de 0,25 J com a velocidade de soldagem de (ν) taxa de repeticao (Rr) fixas de 525mm/min e 39Hz respectivamente e largura temporal de 4 ms. As soldas foram realizadas com proteção gasosa de argônio com vazão de 10 l/min. Os ensaios realizados para a pesquisa foram: análise macrográfica, ensaio de tração e fractografia, ensaio de microdureza e caracterização microestrutural. Para revelação dos detalhes no metal de solda foi utilizado um ataque químico com o reagente Kroll. As medidas de geometria (largura do cordão, largura de união e profundidade) dos cordões de solda, bem como a microestrutura, foram realizadas através de imagens obtidas pelo Microscópio Óptico Neophot 21 e editadas utilizando o software ImageJ. O ensaio de tração foi realizado através de uma Máquina Universal de Ensaios, além do ensaio de microdureza, que foi realizado na escala Vickers. Os resultados obtidos mostraram que o controle da energia do pulso é de fundamental importância para a geração de juntas soldadas adequadas, em processo de soldagem por laser de lâminas finas. Também, os parâmetros geométricos aumentaram em função do aumento da energia de pulso e houve maior formaç... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present work studied the pulsed Nd: YAG laser welding process applied in thin films of the titanium alloy Ti-6Al-4V, used in the coating of sensors that work in the corrosive environment of the sugar-alcohol, chemical, petrochemical and food industry. The pulse energy was varied from 1.0 J to 2.00 J, with increments of 0.25 J with welding speed (ν) and repetition rate (Rr) fixed in 525 mm / min and 39 Hz respectively and time width of 4 ms. An argon gas protection was used with a flow rate of 10 l / min. The tests carried out for the research were: macrographic analysis, tensile and fracture tests, microhardness test and microstructural characterization. A chemical attack with the Kroll reagent was used to reveal details on the weld bead. Measurements based on bead width, union width and depth of the fusion zone as well as the microstructure were performed using images obtained by the Neophot 21 Optical Microscope and edited using the ImageJ software. The tensile test was performed through a Universal Testing Machine, in addition to the microhardness test, which was performed on the Vickers scale. Results showed that the control of the pulse energy is of fundamental importance for the generation of suitable welded joints, in process of laser welding of thin slides. Also, geometric parameters increased as a function of the increase in pulse energy and there was more formation of the α 'phase (martensite) according to the highest peak energy used. Besides that, microhardnes... (Complete abstract click electronic access below) / Mestre
9

Noise in dual-frequency semiconductor and solid-state lasers / Bruit dans les lasers à semiconducteurs et les lasers à solide en régime d’émission bifréquence

De, Syamsundar 29 June 2015 (has links)
Les sources cohérentes de lumière émettant deux fréquences optiques avec une différence largement accordable dans le domaine radiofréquence et un fort degré de corrélation entre leurs fluctuations respectives peuvent être d’un grand intérêt pour de nombreuses applications telles que la photonique micro-onde, les horloges atomiques ultra stables, la physique atomique, la métrologie, etc. C’est le cas des lasers bifréquences émettant deux modes de polarisations linéaires croisées avec une différence de fréquence dans le domaine radiofréquence. Nous comparons les caractéristiques de telles sources bifréquences basées sur des lasers à semiconducteurs (VECSEL: vertical-external-cavity surface-emitting laser) ou des lasers à solide (notamment les solides dopés Nd3+ ou Er3+). Au-delà de la différence évidente entre les mécanismes de gain dans les lasers à semiconducteurs et dans les lasers à solide, le VECSEL bifréquence et le laser Nd:YAG bifréquence ne présentent pas la même dynamique. Le VECSEL bifréquence, comme pour un laser de classe A, a une dynamique dénuée d’oscillations de relaxation puisque la durée de vie des photons dans la cavité est beaucoup plus longue que celle de l’inversion de population. A l’opposé, le laser Nd:YAG bifréquence possède une dynamique présentant des oscillations de relaxation comme pour un laser de classe B, en vertu du fait que la durée de vie des photons dans la cavité est plus courte que celle de l’inversion de population. Dans cette thèse, nous explorons les mécanismes par lesquels cette dynamique, en plus du couplage non linéaire entre les deux modes, gouverne le bruit dans les lasers bifréquences. En particulier, nous analysons à la fois expérimentalement et théoriquement les propriétés spectrales des différents bruits (intensité, phase) ainsi que leurs corrélations dans le cas d’un VECSEL bifréquence de classe A et d’un laser Nd:YAG bifréquence de classe B. Enfin, un modèle de réponse linéaire de deux oscillateurs amortis couplés permet d’interpréter les résultats obtenus sur la corrélation entre ces différents bruits. / Coherent sources emitting two optical frequencies with a widely tunable frequency difference lying in the radio-frequency range and having a high degree of correlation between their fluctuations can be useful for numerous applications such as microwave photonics, ultra-stable atomic clocks, atom manipulation and probing, metrology, etc. Dual-frequency lasers, which emit two orthogonal linearly polarized modes with a frequency difference lying in the radio-frequency range, have huge potentials for the above mentioned applications. We compare the characteristics of such dual-frequency oscillation in lasers based on either semiconductor (VECSEL: vertical-external-cavity surface-emitting laser) or solid-state active media (mainly Nd3+, or Er3+ doped crystalline host). Apart from the obvious difference between the gain mechanisms in semiconductor and solid-state laser media, the dual-frequency VECSEL and the dual-frequency Nd:YAG laser exhibit different dynamical behaviors. The dual-frequency VECSELs exhibit relaxation oscillation free class-A dynamics as the photon lifetime inside the cavity is longer than the population inversion lifetime. On the contrary, the dual-frequency Nd:YAG lasers obey class-B dynamics linked with the fact that the photon lifetime inside the cavity is shorter than the population inversion lifetime, leading to the existence of relaxation oscillations. In this thesis, we figure out how the laser dynamics, in addition to the nonlinear coupling between the two laser modes, governs different noise phenomena in dual-frequency lasers. In particular, we demonstrate, both experimentally and theoretically, the influence of the laser dynamics and the nonlinear coupling between the two modes on the laser noise, by analyzing the spectral properties of the different noises (intensity, phase) and their correlation in a class-A dual-frequency VECSEL (vertical-external-cavity surface emitting laser) and a class-B dual-frequency Nd:YAG laser. Moreover, the noise correlation results are interpreted in terms of the linear response of two coupled damped oscillators.
10

Soldagem em laminas finas de hastelloy c-276 por laser pulsado Nd:YAG

Munekata, Ricardo Mitsuo [UNESP] January 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2011Bitstream added on 2014-06-13T19:35:03Z : No. of bitstreams: 1 munekata_rm_me_ilha.pdf: 4705141 bytes, checksum: 56254cadfa4c90cb796f3b90671140ee (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho estudou a influência da energia do pulso de soldagem, no caso processo laser de Nd:YAG operando no modo pulsado, na soldagem de duas lâminas finas com 100 μm de Hastelloy C-276, utilizado no revestimento de sensores que trabalham em ambiente corrosivo da indústria sucroalcooleira, química petroquímica e alimentícia. Utilizou-se energia de pulso de 1,0 Joule a 2,25 Joules, com incremento de 0,25 Joules com a velocidade de soldagem de (ν) taxa de repetição (Rr) fixas de 525mm/min e 39Hz respectivamente e largura temporal de 4 ms. As soldas foram realizadas com proteção gasosa de argônio. Foram realizadas análises macrográficas e micrográficas das juntas soldadas, através de secções transversais das mesmas e ensaios de microdureza Vickers e ensaio de tração. Os resultados obtidos mostraram que o controle da energia do pulso, em processo de soldagem por laser de lâminas finas é de fundamental importância para a geração de juntas soldadas livres de descontinuidades. Os parâmetros geométricos da junta soldada, tais como largura do cordão, largura de união e profundidade do cordão, aumentaram em função do aumento da energia do pulso. O processo mostrou-se muito sensível à formação de porosidade e à presença de gap entre as lâminas / This work measured experimental investigations were carried out using a pulsed neodymium: yttrium aluminum garnet laser welding to examine the influence of the pulse energy in two thin foil welding with 100 μm thickness, employed to cover sensors that work in corrosive environment of the sugar and alcohol industry,chemical petrochemistry and nourishing. The pulse energy was varied from 1,0 to 2,25 J at an increment of 0.25 J and an increment of 0.25 Joules with a welding speed and(ν) repetition rate (Rr) fixed 525mm/min and 39Hz respectively and 4 ms pulse duration. The specimens were laser-welded in an argon atmosphere. The welds were analyzed by macroscopic and microscopic observations using optical microscopy and micro hardness and tensile test. The results indicated that pulse energy control, in laser welding of thin foils, is of considerable importance for weld quality since it can generate discontinuities free weld joints. The geometric parameters of the welded joints like bead width, connection width and bead depth increased with the pulse energy increasing. The process showed very sensitive to porosity formation and gap between couple

Page generated in 0.0382 seconds