Spelling suggestions: "subject:"laser dde Er,Cr:YSGG"" "subject:"laser dee Er,Cr:YSGG""
1 |
Influência do tratamento da superfície interna da cerâmica sob diferentes parâmetros de irradiação com laser de Er,Cr:YSGG / Influence of the treatment of the internal surface of the ceramic on different parameters of laser irradiation Er,Cr:YSGGInca, Hector Eduardo Cepeda 06 November 2018 (has links)
Objetivos: Este estudo teve como objetivo avaliar a resistência de união entre cimento resinoso e as amostras de zircônia irradiadas como o laser de Er,Cr:YSGG em quatro parâmetros. Foram utilizadas 78 unidades experimentais (12,4 mm x 7,6 mm x 1,6 mm) a partir de blocos de Y-TZP (zircônia tetragonal estabilizada com ítrio) pré-sinterizados. A fim de obter superfícies padronizadas, os espécimes foram lixados com uma sequência decrescente de lixas (600, 1200, 1500). Em seguida, os blocos foram sinterizados em um forno específico, de acordo com as recomendações do fabricante. Os grupos experimentais foram compostos a partir de um fator de variação - tratamento de superfície. Foram formados 6 grupos experimentais (n=13) Controle, sem tratamento de superfície, grupo Rocatec, com tratamento triboquímico (Rocatec System Plus 3M ESPE), e 4 grupos laser (Waterlase Iplus Biolase Inc. Irvine, CA, EUA comprimento de onda 2780nm, 700?s, de 50% de ar e 50% de água, ponta MZ6 600?m): L3W 20Hz (53,57J/cm2), grupo L3W 50Hz (21,43J/cm2), grupo L6W 20Hz (107,14J/cm2), grupo L6W 50Hz (42,68J/cm2). Um espécime de cada grupo foi analisado através de microscopia eletrônica de varredura MEV (10000x). Após dos tratamentos de superfície, em cada bloco de zircônia foram colados 6 cilindros de resina usando cimento dual contendo MDP (Panavia F 2.0). Todas as amostras foram armazenadas em água destilada a 37ºC. O teste de microcisalhamento foi feito na máquina de ensaio universal (Instron 5565 EUA). Três dos 6 tubos colados em cada bloco foram avaliados depois de 24 horas de armazenamento em água a 37ºC e os 3 restantes foram avaliados depois de 2000 ciclos térmicos (5ºC - 30ºC). O tipo de falha foi determinado através de estereomicroscópio. Os dados foram analisados pelos testes de análise de variância (ANOVA) e de Tukey com um nivel de significância de p<0,01. Resultados: O grupo controle positivo (ROCATEC) apresentou diferença significativa (p <0,001) com os demais grupos. Quando foi simulado o envelhecimento térmico (termociclagem), todos os grupos apresentaram diferença significativa (p <0,001) na resistência de união comparada com o protocolo sem termociclagem. O tratamento de superfície convencional ainda é preconizado como uma alternativa válida para melhorar a resistência de união na zircônia. O uso de laser de Er,Cr:YSGG com uma largura de pulso de 700?s dentro dos parâmetros estudados não promoveu mudanças na superfície de zircônia que favorecessem a adesão com cimento resinoso. A termociclagem influenciou negativamente em todos os grupos experimentais. / This study aimed to evaluate the bond strength between resin cement and the irradiated zirconia samples a the Er, Cr: YSGG laser in four parameters. It was used 78 experimental units (12.4mm x 7.6mm x 1.6mm) from pre-sintered Y-TZP (Ytriumstabilized Tetragonal Zirconia) blocks. In order to obtain standardized surfaces the specimens were sanded with a decreasing sanding sequence (600,1200,1500). Then, the blocks form sintered in a specific oven, according to the manufacturer\'s recommendations. The experimental groups were composed of a variation factor - the surface treatment. Thus, 6 experimental groups were formed (n=13). Control, without surface treatment, the Rocatec group, with triboquimic treatment (Rocatec System Plus 3M ESPE), and 4 laser groups (Waterlase Iplus Biolase Inc. Irvine, CA USA wavelength 2780nm, 700?s, 50% air and 50% water, MZ6 600?m tip): L3W 20Hz (53.57J / cm2), L3W 50Hz group (21.43J / cm2), L6W 20Hz group (107.14J / cm2), group L6W 50Hz (42.68J / cm2). One specimen from each group was analyzed by Scanning Electron Microscopy (10000x). After the surface treatments, 6 resin cylinders were bonded to each zirconia block using dual cement containing MDP (Panavia F 2.0). All samples were stored in distilled water at 37 ° C. The micro-shear test was performed on the universal test machine (Instron 5565 USA). 3 of the 6 tubes pasted in each block were evaluated after 24 hours of storage in 37 ° C water and the remaining 3 were evaluated after 2000 thermal cycles (5 ° C - 30 ° C). The type of failure was determined by stereomicroscope. The data were analyzed by a test for analysis of variance (ANOVA) and tukey with a significance level of p <0.01. Results: The positive control group (ROCATEC), evaluated immediately after cementation, showed a better bond strength and there was no significant difference when thermal aging was simulated (thermocycling), nor did it differ significantly from the groups without thermocycling of 3w20Hz or 6w50hz. Conventional surface treatment is still advocated as a valid alternative to improve bond strength in zirconia. The use of Er, Cr: YSGG laser with a pulse width of 700?s within the studied parameters did not promote changes in the zirconia surface that favored adhesion with resin cement. Thermocycling influenced negatively all experimental groups.
|
2 |
Avaliação longitudinal da adesão à dentina irradiado pelo laser de Er,Cr:YSGG / Longitudinal evaluation of adherence to dentin irradiated by laser Er, Cr: YSGG.Goldman, Juliana Elston 01 December 2009 (has links)
O laser de Er,Cr:YSGG se apresenta como um aliado aos procedimentos minimamente invasivos. Porém, pouco se sabe sobre a longevidade da resistência de união à dentina irradiada por este equipamento. Dessa forma, o objetivo deste estudo foi avaliar a resistência de união à dentina irradiada após 90 dias de armazenamento. Para tanto, foram utilizados 64 molares humanos hígidos, que tiveram as superfícies oclusais desgastadas até a exposição de uma superfície de dentina. Esta superfície foi tratada com: abrasão com lixa SiC 600# (controle) e irradiação com o laser de Er,Cr:YSGG em 2W (90,9 J/cm2) ou 4W (181,8 J/cm2). Foram utilizados os seguintes sistemas adesivos: Adper Single Bond (3MESPE), Clearfil SE (Kuraray) ou Clearfil S3 (Kuraray), e a confecção de um bloco de resina composta Z250-3MESPE. Os dentes foram seccionados para a obtenção de palitos para o teste de microtração. Metade dos palitos foi ensaiada imediatamente, e a outra metade após 90 dias de armazenamento em água destilada. Os resultados mostraram que em todos os grupos em que foi utilizado o laser Er,Cr:YSGG apresentaram os menores valores de resistência adesiva. Com exceção do grupo controle/Clearfil S3, todos os grupos apresentaram decréscimo nos valores de resistência adesiva após os 90 dias de armazenamento. Entre os sistemas adesivos utilizados, o Single Bond apresentou os melhores valores de resistência adesiva, demonstrando maior estabilidade frente aos 90 dias de desafio/armazenamento. / In the minimally invasive dentistry, the Er,Cr:YSGG laser has been considered as an efficient equipment. However, little is known about the longevity of the bond strength to irradiated dentin. So, the objective of this study was to evaluate the bond strength values to laser irradiated dentin after 90 days storage. Sixty-four sound human molars were used. A flat coronal dentin surface was obtained by removing the oclusal enamel with a slow speed diamond saw. Dentin surfaces were treated with: abrasion with SiC 600# (control group) and laser irradiation with Er,Cr:YSGG in 2W or 4W. Subsequently, adhesive systems were used: Adper Single Bond (3MESPE), Clearfil SE (Kuraray) or ClearfilS3 (Kuraray). After adhesive procedures, a block of Z250-3MESPE composite resin was build up on each tooth. The teeth were sectioned in order to obtain samples for the microtensile bond strength test. Half of the samples was tested immediately, and the other half were stored for 90 days in distilled water. The results showed that all the groups in which laser was used presenter lower bond strength values. With the exception of Clearfil S3/control group, all groups showed weaker bond strength after 90 days of storage. Among all the adhesives systems used, Single Bond presented the best results, showing more stability after 90 days of storage.
|
3 |
Avaliação longitudinal da adesão à dentina irradiado pelo laser de Er,Cr:YSGG / Longitudinal evaluation of adherence to dentin irradiated by laser Er, Cr: YSGG.Juliana Elston Goldman 01 December 2009 (has links)
O laser de Er,Cr:YSGG se apresenta como um aliado aos procedimentos minimamente invasivos. Porém, pouco se sabe sobre a longevidade da resistência de união à dentina irradiada por este equipamento. Dessa forma, o objetivo deste estudo foi avaliar a resistência de união à dentina irradiada após 90 dias de armazenamento. Para tanto, foram utilizados 64 molares humanos hígidos, que tiveram as superfícies oclusais desgastadas até a exposição de uma superfície de dentina. Esta superfície foi tratada com: abrasão com lixa SiC 600# (controle) e irradiação com o laser de Er,Cr:YSGG em 2W (90,9 J/cm2) ou 4W (181,8 J/cm2). Foram utilizados os seguintes sistemas adesivos: Adper Single Bond (3MESPE), Clearfil SE (Kuraray) ou Clearfil S3 (Kuraray), e a confecção de um bloco de resina composta Z250-3MESPE. Os dentes foram seccionados para a obtenção de palitos para o teste de microtração. Metade dos palitos foi ensaiada imediatamente, e a outra metade após 90 dias de armazenamento em água destilada. Os resultados mostraram que em todos os grupos em que foi utilizado o laser Er,Cr:YSGG apresentaram os menores valores de resistência adesiva. Com exceção do grupo controle/Clearfil S3, todos os grupos apresentaram decréscimo nos valores de resistência adesiva após os 90 dias de armazenamento. Entre os sistemas adesivos utilizados, o Single Bond apresentou os melhores valores de resistência adesiva, demonstrando maior estabilidade frente aos 90 dias de desafio/armazenamento. / In the minimally invasive dentistry, the Er,Cr:YSGG laser has been considered as an efficient equipment. However, little is known about the longevity of the bond strength to irradiated dentin. So, the objective of this study was to evaluate the bond strength values to laser irradiated dentin after 90 days storage. Sixty-four sound human molars were used. A flat coronal dentin surface was obtained by removing the oclusal enamel with a slow speed diamond saw. Dentin surfaces were treated with: abrasion with SiC 600# (control group) and laser irradiation with Er,Cr:YSGG in 2W or 4W. Subsequently, adhesive systems were used: Adper Single Bond (3MESPE), Clearfil SE (Kuraray) or ClearfilS3 (Kuraray). After adhesive procedures, a block of Z250-3MESPE composite resin was build up on each tooth. The teeth were sectioned in order to obtain samples for the microtensile bond strength test. Half of the samples was tested immediately, and the other half were stored for 90 days in distilled water. The results showed that all the groups in which laser was used presenter lower bond strength values. With the exception of Clearfil S3/control group, all groups showed weaker bond strength after 90 days of storage. Among all the adhesives systems used, Single Bond presented the best results, showing more stability after 90 days of storage.
|
4 |
Avaliação do efeito de diferentes lasers de alta intensidade no tratamento de superfície da cerâmica Y-TZP pré e pós sinterização / Effect evaluation of different high-intensity lasers on the surface treatment of Y-TZP ceramic before and after sinteringSilva, Amanda Verna e 12 September 2011 (has links)
O objetivo deste estudo foi avaliar os efeitos dos lasers de Nd:YAG, CO2 e Er,Cr:YSGG no tratamento de superfície da cerâmica Y-TZP antes e depois da sinterização final, por meio de Microscopia Eletrônica de Varredura (MEV), mensuração da rugosidade de superfície (Ra) e teste de resistência adesiva por microcisalhamento (RAD). Para tanto, barras de Y-TZP foram confeccionadas e distribuídas entre as 3 fases do experimento, sendo as duas primeiras fases seletivas para a identificação dos parâmetros lasers a serem utilizados na fase 3 de análise da RAD. Na fase 1 MEV - foram testados parâmetros que variavam entre 50 e 100 mJ para o laser de Nd:YAG, 2 a 4W para o laser de CO2 e 1 a 3,5W para o laser de Er,Cr:YSGG, testados antes ou após a sinterização da Y-TZP. Observou-se que a maioria dos tratamentos foram capazes de promover alterações na cerâmica com diferentes intensidades dependendo do parâmetro utilizado. Para a fase 2 Ra foram selecionados apenas os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG aplicados antes da sinterização da cerâmica, sendo que cada laser foi avaliado individualmente e comparados ao tratamento de superfície com o sistema Rocatec. Os tratamentos com os maiores valores de Ra foram: para o laser de Nd:YAG - 1,6W-20Hz (11.623±3,419) e para o laser de Er,Cr:YSGG - 3W (6,051±1,991). O sistema Rocatec apresentou os menores valores de rugosidade (1,297±0,026). Para a fase 3 do estudo RAD foram selecionados os parâmetros que apresentaram os maiores valores de Ra para cada laser, além do parâmetro com características favoráveis à adesão observado na fase 1 MEV. Sendo assim, o teste de microcisalhamento foi realizado entre a cerâmica Y-TZP tratada com os lasers antes da sinterização final, nos parâmetros de 1,6W e 1,2W para o laser de Nd:YAG e 3W para o laser de Er,Cr:YSGG; e com o sistema Rocatec, utilizando-se dois cimentos resinosos de dupla ativação (Panavia e RelyX U100). A análise estatística ANOVA Split-Plot dos dados de RAD obtidos revelou que não houve diferença estatística entre os cimentos estudados. Porém, no fator tratamentos de superfície observou-se que os maiores valores de RAD foram obtidos para o sistema Rocatec (20,92±3,4MPa). Os dois parâmetros utilizados para o laser de Nd:YAG foram semelhantes entre si com valores de RAD intermediários (1,2W=9,79±4 MPa e 1,6W=11,35±3,64 MPa) e o tratamento com o laser de Er,Cr:YSGG apresentou os menores valores de RAD (1,43±1,21MPa). Pôde-se concluir que os tratamentos de superfície com todos os lasers testados nos parâmetros de irradiação após a sinterização, provocaram danos à cerâmica Y-TZP. Os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG antes da sinterização, apesar de apresentarem características micromorfológicas sugestivas de aumento da área de superfície, não foram suficientes para aumentar a resistência adesiva entre a Y-TZP e os cimentos resinosos testados. / The aim of this study was to evaluate the effects of Nd:YAG, CO2 and Er,Cr:YSGG lasers on the surface treatment of Y-TZP ceramic before and after the final sintering by means of Scanning Electron Microscope (SEM), surface roughness measurement (Ra) and microshear bond strength adhesive resistance test (RAD). In order to do so, Y-TZP bars were produced and distributed among the three experimental phases, being the two first ones selective in what regards identifying parameters for the lasers used in phase 3 of the RAD analysis. In phase 1 SEM parameters varying from 50 to 100 mJ were tested for the Nd:YAG laser, from 2 to 4W for the CO2 laser and from 1 to 3,5W for the Er,Cr:YSGG laser, either before or after the Y-TZP sintering. It was observed that most treatments were able to promote changes in the ceramic with varied intensity according to the parameter used. In phase 2 Ra only treatments with Nd:YAG and Er,Cr:YSGG lasers applied before ceramic sintering were selected, and each laser was individually evaluated and compared to the surface treatment with Rocatec system. The treatments which had the highest Ra values were: 1,6W-20Hz (11.623±3,419) for the Nd:YAG laser and 3W (6,051±1,991) for Er,Cr:YSGG. Rocatec system showed the lowest roughness levels (1,297±0,026). As for phase 3 of the study RAD the highest Ra parameters for each laser were selected as well as the parameter with favorable characteristics to adherence observed in phase 1 SEM. Therefore, the microshear bond strength test was done not only in the Y-TZP ceramic treated with lasers before the final sintering (using 1,6W and 1,2W parameters for the Nd:YAG laser and 3W for Er,Cr:YSGG), but also in the Rocatec system, making use of two double activation resin cements (Panavia e RelyX U100). The ANOVA Split-Plot statistical analysis of the RAD data showed that there were no statistical variations concerning the studied cements. However, in what regards the surface treatments, it was observed that the highest RAD values were obtained for the Rocatec system (20,92±3,4MPa). Both parameters used for the Nd:YAG laser were similar, presenting intermediate RAD values (1,2W=9,79±4 and 1,6W=11,35±3,64 MPa). The treatment which used Er,Cr:YSGG laser presented the lowest RAD values (1,43±1,21MPa). It was possible to conclude that surface treatments with all tested lasers in the irradiation parameters after sintering caused damage to the Y-TZP ceramic. Treatments making use of Nd:YAG and Er,Cr:YSGG lasers before the sintering were not enough in order to increase the adhesive resistance between Y-TZP and the resin cements tested, even though they presented micromorphological characteristics that indicated growth in the surface area.
|
5 |
Avaliação do efeito de diferentes lasers de alta intensidade no tratamento de superfície da cerâmica Y-TZP pré e pós sinterização / Effect evaluation of different high-intensity lasers on the surface treatment of Y-TZP ceramic before and after sinteringAmanda Verna e Silva 12 September 2011 (has links)
O objetivo deste estudo foi avaliar os efeitos dos lasers de Nd:YAG, CO2 e Er,Cr:YSGG no tratamento de superfície da cerâmica Y-TZP antes e depois da sinterização final, por meio de Microscopia Eletrônica de Varredura (MEV), mensuração da rugosidade de superfície (Ra) e teste de resistência adesiva por microcisalhamento (RAD). Para tanto, barras de Y-TZP foram confeccionadas e distribuídas entre as 3 fases do experimento, sendo as duas primeiras fases seletivas para a identificação dos parâmetros lasers a serem utilizados na fase 3 de análise da RAD. Na fase 1 MEV - foram testados parâmetros que variavam entre 50 e 100 mJ para o laser de Nd:YAG, 2 a 4W para o laser de CO2 e 1 a 3,5W para o laser de Er,Cr:YSGG, testados antes ou após a sinterização da Y-TZP. Observou-se que a maioria dos tratamentos foram capazes de promover alterações na cerâmica com diferentes intensidades dependendo do parâmetro utilizado. Para a fase 2 Ra foram selecionados apenas os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG aplicados antes da sinterização da cerâmica, sendo que cada laser foi avaliado individualmente e comparados ao tratamento de superfície com o sistema Rocatec. Os tratamentos com os maiores valores de Ra foram: para o laser de Nd:YAG - 1,6W-20Hz (11.623±3,419) e para o laser de Er,Cr:YSGG - 3W (6,051±1,991). O sistema Rocatec apresentou os menores valores de rugosidade (1,297±0,026). Para a fase 3 do estudo RAD foram selecionados os parâmetros que apresentaram os maiores valores de Ra para cada laser, além do parâmetro com características favoráveis à adesão observado na fase 1 MEV. Sendo assim, o teste de microcisalhamento foi realizado entre a cerâmica Y-TZP tratada com os lasers antes da sinterização final, nos parâmetros de 1,6W e 1,2W para o laser de Nd:YAG e 3W para o laser de Er,Cr:YSGG; e com o sistema Rocatec, utilizando-se dois cimentos resinosos de dupla ativação (Panavia e RelyX U100). A análise estatística ANOVA Split-Plot dos dados de RAD obtidos revelou que não houve diferença estatística entre os cimentos estudados. Porém, no fator tratamentos de superfície observou-se que os maiores valores de RAD foram obtidos para o sistema Rocatec (20,92±3,4MPa). Os dois parâmetros utilizados para o laser de Nd:YAG foram semelhantes entre si com valores de RAD intermediários (1,2W=9,79±4 MPa e 1,6W=11,35±3,64 MPa) e o tratamento com o laser de Er,Cr:YSGG apresentou os menores valores de RAD (1,43±1,21MPa). Pôde-se concluir que os tratamentos de superfície com todos os lasers testados nos parâmetros de irradiação após a sinterização, provocaram danos à cerâmica Y-TZP. Os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG antes da sinterização, apesar de apresentarem características micromorfológicas sugestivas de aumento da área de superfície, não foram suficientes para aumentar a resistência adesiva entre a Y-TZP e os cimentos resinosos testados. / The aim of this study was to evaluate the effects of Nd:YAG, CO2 and Er,Cr:YSGG lasers on the surface treatment of Y-TZP ceramic before and after the final sintering by means of Scanning Electron Microscope (SEM), surface roughness measurement (Ra) and microshear bond strength adhesive resistance test (RAD). In order to do so, Y-TZP bars were produced and distributed among the three experimental phases, being the two first ones selective in what regards identifying parameters for the lasers used in phase 3 of the RAD analysis. In phase 1 SEM parameters varying from 50 to 100 mJ were tested for the Nd:YAG laser, from 2 to 4W for the CO2 laser and from 1 to 3,5W for the Er,Cr:YSGG laser, either before or after the Y-TZP sintering. It was observed that most treatments were able to promote changes in the ceramic with varied intensity according to the parameter used. In phase 2 Ra only treatments with Nd:YAG and Er,Cr:YSGG lasers applied before ceramic sintering were selected, and each laser was individually evaluated and compared to the surface treatment with Rocatec system. The treatments which had the highest Ra values were: 1,6W-20Hz (11.623±3,419) for the Nd:YAG laser and 3W (6,051±1,991) for Er,Cr:YSGG. Rocatec system showed the lowest roughness levels (1,297±0,026). As for phase 3 of the study RAD the highest Ra parameters for each laser were selected as well as the parameter with favorable characteristics to adherence observed in phase 1 SEM. Therefore, the microshear bond strength test was done not only in the Y-TZP ceramic treated with lasers before the final sintering (using 1,6W and 1,2W parameters for the Nd:YAG laser and 3W for Er,Cr:YSGG), but also in the Rocatec system, making use of two double activation resin cements (Panavia e RelyX U100). The ANOVA Split-Plot statistical analysis of the RAD data showed that there were no statistical variations concerning the studied cements. However, in what regards the surface treatments, it was observed that the highest RAD values were obtained for the Rocatec system (20,92±3,4MPa). Both parameters used for the Nd:YAG laser were similar, presenting intermediate RAD values (1,2W=9,79±4 and 1,6W=11,35±3,64 MPa). The treatment which used Er,Cr:YSGG laser presented the lowest RAD values (1,43±1,21MPa). It was possible to conclude that surface treatments with all tested lasers in the irradiation parameters after sintering caused damage to the Y-TZP ceramic. Treatments making use of Nd:YAG and Er,Cr:YSGG lasers before the sintering were not enough in order to increase the adhesive resistance between Y-TZP and the resin cements tested, even though they presented micromorphological characteristics that indicated growth in the surface area.
|
6 |
Estudo in vitro dos efeitos do laser de Er,Cr:YSGG quando empregado para prevenção da desmineralização da dentinaSilva, Elizabete dos Santos Ferreira January 2018 (has links)
Orientadora: Profa. Dra. Patrícia Aparecida da Ana / Coorientadora: Profa. Dra. Ilka Tiemy Kato Prates / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Biomédica, São Bernardo do Campo, 2018. / Lasers de erbio podem ser usados para prevencao de carie radicular, o que e de suma importancia para os idosos. Contudo, parametros seguros e eficazes de irradiacao para a dentina radicular ainda nao foram determinados empregando-se o laser de Er,Cr:YSGG para tal finalidade. Esse estudo tem por objetivo avaliar os aumentos de temperatura pulpar e superficial, assim como as alteracoes morfologicas, decorrentes da irradiacao da dentina radicular com laser de Er,Cr:YSGG quando empregado com finalidade preventiva, e avaliar os efeitos de um dos parametros estabelecidos na composicao e resistencia a desmineralizacao da dentina radicular. O estudo foi dividido em duas fases experimentais. Na primeira, os efeitos morfologicos e de variacao de temperatura pulpar e superficial foram avaliados a partir de tres potencias medias do laser de Er,Cr:YSGG, enquanto que, na segunda, um dos parametros selecionados foi avaliado quanto as mudancas composicionais, morfologicas e opticas promovidas na dentina radicular. Na primeira fase experimental, 30 dentes unirradiculares humanos e 30 blocos de dentina radicular bovina foram aleatoriamente distribuidos em tres grupos experimentais para irradiacao com laser de Er,Cr:YSGG (2,78 £gm, 600 £gm, 20 Hz, 60 £gs, sem refrigeracao): G1a ¡Vpotencia media de 0,10W; G1b - potencia media de 0,25W; G1c - potencia media de 0,50W. Foram determinadas as variacoes de temperatura intrapulpar empregando-se termopares, variacoes de temperatura superficial com termografia e alteracoes morfologicas por microscopia eletronica de varredura (MEV). Na segunda fase experimental, 75 blocos de dentina radicular bovina foram aleatoriamente distribuidos em 5 grupos experimentais: G1b: sem tratamento; G2b: tratamento com fluor fosfato acidulado (FFA, 1,23% F-, pH= 3,6 = 3,9); G3b: irradiacao com potencia media de 0,25W; G4b: irradiacao laser seguida de aplicacao de FFA; G5b: aplicacao de FFA seguida da irradiacao laser. Foram efetuadas avaliacao composicional por espectroscopia de absorcao no infravermelho por transformada de Fourier (FTIR), optica por tomografia por coerenca optica (OCT) e morfologica por MEV. Em seguida, as amostras foram submetidas a ciclagem de pH por 8 dias e, no fim, foi avaliado o coeficiente de atenuacao optco obtido por nova avaliacao por OCT. A analise estatistica foi efetuada individualmente para cada variavel resposta, sendo adotado o nivel de significancia estatistica de 5%. Todos os parametros laser promoveram alteracoes de temperatura inferior ao limiar para danos pulpares; contudo, apenas o grupo tratado com 0,50 W promoveu aumentos de temperatura superficial superiores a 100o C, indicativos de alteracoes quimicas na dentina. Os grupos irradiados com 0,25W e 0,50 W promoveram microablacoes na dentina, observados pelo MEV. Na segunda fase experimental,
observou-se pelo FTIR que a irradiacao laser isoladamente nao altera a composicao da dentina, mas a aplicacao previa de FFA seguida da irradiacao laser diminuiu significativamente o conteudo de ¿Þ3¿Þ4 carbonato da dentina. Da mesma forma, este tratamento tambem promove maior alteracao morfologica e de coeficiente de atenuacao optica quando comparado aos tratamentos isoladamente. Apos desmineralizacao, observou-se que tanto a irradiacao laser isoladamente, quanto a aplicacao de FFA previamente a irradiacao, promoveram aumento significativo do coeficiente de atenuacao optico, indicando menor desmineralizacao das amostras para este grupo. Desta forma, foi possivel concluir que o laser de Er,Cr:YSGG apresenta potencial para uso em prevencao da desmineralizacao da dentina radicular, sendo segura sua aplicacao com potencia media de 0,25W e mais eficiente quando precedido da aplicacao de FFA. / Erbium lasers can be used to prevent root caries, which is imporant for the elderly. However, safe and effective irradiation parameters have not yet been determined for root dentin using the Er,Cr:YSGG laser for this purpose. The objective of this study was to evaluate the pulp and surface temperature increases, as well as the morphological alterations, due to Er,Cr:YSGG laser irradiation on root dentin when used for preventive purposes, and to evaluate the effects of one of the parameters in the composition and resistance to demineralization of root dentin. The study was split into two experimental phases. In the first one, the morphological and pulp and surface temperature variations were evaluated from three average powers of the Er,Cr:YSGG laser, while in the second phase, the compositional, morphological and optical properties promoted by one selected laser parameter were evaluated in root dentin. In the first experimental phase, 30 unirradicular human teeth and 30 bovine root dentin slabs were randomly distributed in three experimental groups for irradiation with Er,Cr:YSGG laser (2.78 £gm, 600 £gm, 20 Hz, 60 £gs, without refrigeration): G1a - average power of 0.10W; G1b - average power of 0.25W; G1c - average power of 0.50W. The pulpal temperature variations were determined using fast response thermocouples, the surface temperature variations were measured using infrared thermography and morphological changes were observed by scanning electron microscopy (SEM). In the second experimental phase, 75 slabs of bovine root dentin were randomly distributed in 5 experimental groups: G1b: without treatment; G2b: treatment with acidulated fluoride phosphate (APF, 1.23% F-, pH = 3.6 = 3.9); G3b: irradiation with average power of 0.25W; G4b: laser irradiation followed by APF application; G5b: application of APF followed by laser irradiation. The compositional evaluation was performed by Fourier transformed infrared spectroscopy (FTIR), the optical aspect was observed by optical coherence tomography (OCT) and morphology was evaluated by SEM. Afterwards, the samples were submitted to pH-cycling for 8 days and, finally, the optical attenuation coefficient was obtained by a new OCT evaluation. The statistical analysis was performed individually for each response variable, considering the level of significance of 5%. All the laser parameters promoted changes in temperature below the threshold for pulp damage; however, only the group treated with 0.50 W promoted surface temperature increases above 100 ¢XC, indicative of chemical changes in dentin. The groups irradiated with 0.25W and 0.50 W promoted microablation in dentin. In the second experimental phase, it was observed that the laser irradiation alone does not alter the composition of the dentin, but the previous application of APF followed by the laser irradiation significantly decreased the content of ¿Þ3¿Þ4 carbonate of the dentin. In the same way, this treatment also promotes greater morphological alterations when compared to treatments alone. After demineralization, it was observed that both the laser irradiation alone and the application of APF previously to the laser irradiation promoted a significant increase in the optical attenuation coefficient, indicating a lower demineralization of this group. In this way, it was possible to conclude that the Er,Cr:YSGG laser presents potential for use for preventing root dentin demineralization. Its application is safe with a mean power of 0.25W and more efficient when preceded by APF application.
|
7 |
Avaliação in vitro da morfologia e da resistência de união de adesivos à dentina humana hígida ou submetida à ciclagem erosiva e irradiada com os lasers de Er:YAG e Er,Cr:YSGG / In vitro evaluation of the morphology and the bond strength of adhesives to sound and artificially eroded human dentin irradiated with Er:YAG and Er,Cr:YSGG laserRamos, Thaysa Monteiro 04 July 2012 (has links)
A erosão dental provoca alterações histológicas complexas na dentina e, apesar do aumento da ocorrência desta patologia na última década, a literatura apresenta poucos estudos sobre a adesão na dentina erodida. Com o aprimoramento da tecnologia e o conhecimento de que os lasers de érbio apresentam grande afinidade pela água e hidroxiapatita, sua utilização tem sido considerada um método alternativo para tratamento da superfície dentinária antes dos procedimentos adesivos. Assim, o objetivo deste trabalho in vitro foi avaliar o efeito de diferentes tratamentos de superfície (ponta diamantada, laser de Er:YAG 2,94 m, 60 mJ, 2 Hz, 0,2 W, 19,3 J/cm2 - e laser de Er,Cr:YSGG 2,78 m, 50 mJ, 30 Hz, 1,5 W, 4,5 J/cm2), prévios ao tratamento restaurador, tanto na dentina humana hígida quanto na dentina artificialmente erodida. Metade das amostras foi submetida à ciclagem erosiva, a qual foi realizada durante 5 dias por meio da imersão em solução de ácido cítrico 0,05 M (pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Na fase experimental 1, 32 fragmentos de dentina foram divididos aleatoriamente em 8 grupos (n = 4) e com o auxílio da Microscopia Eletrônica de Varredura (MEV), realizou-se a análise da morfologia da superfície da dentina hígida e da submetida à ciclagem erosiva, após os diferentes tratamentos de superfície. Na fase experimental 2, 192 terceiros molares humanos foram divididos aleatoriamente em 2 grupos (dentina hígida e dentina submetida à ciclagem erosiva) e 8 subgrupos (n = 12) para avaliação da resistência de união entre as superfícies tratadas e 2 sistemas adesivos (01 autocondicionante e 01 com condicionamento ácido prévio), por meio do ensaio de microtração e da análise do padrão de fratura. Para o ensaio de microtração, blocos de resina composta microhíbrida foram confeccionados na superfície de dentina e, após armazenados em água destilada-deionizada por 24h (37oC), palitos foram obtidos para serem tracionados na máquina de ensaio universal (0,5mm/min). A análise do padrão de fratura realizada em microscópio ótico (40x) e as avaliações das eletromicrografias foram feitas de forma descritiva. Os valores obtidos de resistência de união(MPa) foram submetidos aos testes de ANOVA (dois fatores) e de comparações múltiplas de Tukey (p<0,05). A análise morfológica de superfície mostrou alterações significativas da dentina hígida e da dentina artificialmente erodida, submetidas aos diferentes tratamentos de superfície. Quanto à resistência de união, na dentina hígida, o grupo controle, tanto do sistema autocondicionante (54,69 ± 7,80 MPa) quanto do condicionamento ácido total (47,36 ± 9,35 MPa), apresentou valores significativamente maiores que os outros grupos, sendo, porém, diferentes entre si. Na dentina erodida, a maior resistência de união foi alcançada com o grupo tratado com o laser de Er,Cr:YSGG associado ao adesivo autocondicionante (28,26 ± 9,22 MPa), o qual foi significativamente diferente de todos demais grupos. Com base nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que em dentina hígida, os tratamentos de superfície com os lasers de Er:YAG e Er,Cr:YSGG apresentaram resultados de adesão inferiores, mas satisfatórios, em relação ao grupo controle. Já em substrato dentinário erodido, a irradiação com laser de Er,Cr:YSGG, associada ao uso de sistema adesivo autocondicionante, promoveu efeito positivo para a adesão à resina composta. / Dental erosion can cause complex histological changes in dentin and, despite the increase in its incidence during the last decade, limited information is available regarding adhesion to eroded dentin. With improvements in technology and due to the fact that the erbium lasers have high affinity to water and hydroxyapatite, the use of laser can consist on an alternative for the treatment of dentin surface before adhesive procedures. The aim of this in vitro study was to evaluate the effect of different surface treatments (diamond bur, Er:YAG laser 2.94 m, 60 mJ, 2 Hz, 0.2 W, 19.3 J/cm2 - and Er,Cr:YSGG laser 2.78 m, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm2) prior to restorative treatment, in sound and artificially eroded human dentin. Half of the samples was submitted to the erosive cycling, which was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1h, between acid attacks), during 5 days. In phase 1, 32 dentin fragments were randomly divided into 8 groups (n = 4). The analysis of surface morphology of both sound and eroded dentin was performed by Scanning Electron Microscopy (SEM), after the different surface treatments. In phase 2, 192 human third molars were randomly divided into 2 groups (sound and eroded dentin) and 8 subgroups (n=12) to evaluate the bond strength between the treated surfaces and composite resin, with two adhesive systems (self-etching and total-etching) by means of the microtensile bond strength (TBS) test and fracture pattern analysis. For the microtensile bond strength test, blocks of composite resin were bonded to the samples and, after 24 h-storage in distilled/deionized water (37°C), stick-shapped samples were obtained and submitted to TBS test in a universal testing machine (0.5 mm/min). The fracture pattern was performed with an optical microscopy (40x) and the evaluations of the electromicrographs were made under a descriptive mode. The bond strength values (MPa) were analyzed by two-way ANOVA and Tukey tests ( = 0.05). In sound dentin, for the control group, both self-etching (54.69 ± 7.8 MPa) and total-etching adhesive system (47.36 ± 9.3 MPa) showed significantly higher values than all other groups (p<0.05), even though they differ from each other. However, in eroded dentin groups, the self-etching on the samples treated with the Er,Cr:YSGG laser presented the highest mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other treatments (p<0.05). Based on the irradiation parameters considered for this study, it can be concluded that in healthy dentin, the surface treatment with Er:YAG and Er,Cr:YSGG irradiation showed bonding values lower than the control group, but they presented satisfactory results. However, in eroded dentin, the use of Er,Cr:YSGG laser, associated with the self-etching adhesive system, promoted positive effect on adhesion to composite resin.
|
8 |
Avaliação in vitro da morfologia e da resistência de união de adesivos à dentina humana hígida ou submetida à ciclagem erosiva e irradiada com os lasers de Er:YAG e Er,Cr:YSGG / In vitro evaluation of the morphology and the bond strength of adhesives to sound and artificially eroded human dentin irradiated with Er:YAG and Er,Cr:YSGG laserThaysa Monteiro Ramos 04 July 2012 (has links)
A erosão dental provoca alterações histológicas complexas na dentina e, apesar do aumento da ocorrência desta patologia na última década, a literatura apresenta poucos estudos sobre a adesão na dentina erodida. Com o aprimoramento da tecnologia e o conhecimento de que os lasers de érbio apresentam grande afinidade pela água e hidroxiapatita, sua utilização tem sido considerada um método alternativo para tratamento da superfície dentinária antes dos procedimentos adesivos. Assim, o objetivo deste trabalho in vitro foi avaliar o efeito de diferentes tratamentos de superfície (ponta diamantada, laser de Er:YAG 2,94 m, 60 mJ, 2 Hz, 0,2 W, 19,3 J/cm2 - e laser de Er,Cr:YSGG 2,78 m, 50 mJ, 30 Hz, 1,5 W, 4,5 J/cm2), prévios ao tratamento restaurador, tanto na dentina humana hígida quanto na dentina artificialmente erodida. Metade das amostras foi submetida à ciclagem erosiva, a qual foi realizada durante 5 dias por meio da imersão em solução de ácido cítrico 0,05 M (pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Na fase experimental 1, 32 fragmentos de dentina foram divididos aleatoriamente em 8 grupos (n = 4) e com o auxílio da Microscopia Eletrônica de Varredura (MEV), realizou-se a análise da morfologia da superfície da dentina hígida e da submetida à ciclagem erosiva, após os diferentes tratamentos de superfície. Na fase experimental 2, 192 terceiros molares humanos foram divididos aleatoriamente em 2 grupos (dentina hígida e dentina submetida à ciclagem erosiva) e 8 subgrupos (n = 12) para avaliação da resistência de união entre as superfícies tratadas e 2 sistemas adesivos (01 autocondicionante e 01 com condicionamento ácido prévio), por meio do ensaio de microtração e da análise do padrão de fratura. Para o ensaio de microtração, blocos de resina composta microhíbrida foram confeccionados na superfície de dentina e, após armazenados em água destilada-deionizada por 24h (37oC), palitos foram obtidos para serem tracionados na máquina de ensaio universal (0,5mm/min). A análise do padrão de fratura realizada em microscópio ótico (40x) e as avaliações das eletromicrografias foram feitas de forma descritiva. Os valores obtidos de resistência de união(MPa) foram submetidos aos testes de ANOVA (dois fatores) e de comparações múltiplas de Tukey (p<0,05). A análise morfológica de superfície mostrou alterações significativas da dentina hígida e da dentina artificialmente erodida, submetidas aos diferentes tratamentos de superfície. Quanto à resistência de união, na dentina hígida, o grupo controle, tanto do sistema autocondicionante (54,69 ± 7,80 MPa) quanto do condicionamento ácido total (47,36 ± 9,35 MPa), apresentou valores significativamente maiores que os outros grupos, sendo, porém, diferentes entre si. Na dentina erodida, a maior resistência de união foi alcançada com o grupo tratado com o laser de Er,Cr:YSGG associado ao adesivo autocondicionante (28,26 ± 9,22 MPa), o qual foi significativamente diferente de todos demais grupos. Com base nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que em dentina hígida, os tratamentos de superfície com os lasers de Er:YAG e Er,Cr:YSGG apresentaram resultados de adesão inferiores, mas satisfatórios, em relação ao grupo controle. Já em substrato dentinário erodido, a irradiação com laser de Er,Cr:YSGG, associada ao uso de sistema adesivo autocondicionante, promoveu efeito positivo para a adesão à resina composta. / Dental erosion can cause complex histological changes in dentin and, despite the increase in its incidence during the last decade, limited information is available regarding adhesion to eroded dentin. With improvements in technology and due to the fact that the erbium lasers have high affinity to water and hydroxyapatite, the use of laser can consist on an alternative for the treatment of dentin surface before adhesive procedures. The aim of this in vitro study was to evaluate the effect of different surface treatments (diamond bur, Er:YAG laser 2.94 m, 60 mJ, 2 Hz, 0.2 W, 19.3 J/cm2 - and Er,Cr:YSGG laser 2.78 m, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm2) prior to restorative treatment, in sound and artificially eroded human dentin. Half of the samples was submitted to the erosive cycling, which was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1h, between acid attacks), during 5 days. In phase 1, 32 dentin fragments were randomly divided into 8 groups (n = 4). The analysis of surface morphology of both sound and eroded dentin was performed by Scanning Electron Microscopy (SEM), after the different surface treatments. In phase 2, 192 human third molars were randomly divided into 2 groups (sound and eroded dentin) and 8 subgroups (n=12) to evaluate the bond strength between the treated surfaces and composite resin, with two adhesive systems (self-etching and total-etching) by means of the microtensile bond strength (TBS) test and fracture pattern analysis. For the microtensile bond strength test, blocks of composite resin were bonded to the samples and, after 24 h-storage in distilled/deionized water (37°C), stick-shapped samples were obtained and submitted to TBS test in a universal testing machine (0.5 mm/min). The fracture pattern was performed with an optical microscopy (40x) and the evaluations of the electromicrographs were made under a descriptive mode. The bond strength values (MPa) were analyzed by two-way ANOVA and Tukey tests ( = 0.05). In sound dentin, for the control group, both self-etching (54.69 ± 7.8 MPa) and total-etching adhesive system (47.36 ± 9.3 MPa) showed significantly higher values than all other groups (p<0.05), even though they differ from each other. However, in eroded dentin groups, the self-etching on the samples treated with the Er,Cr:YSGG laser presented the highest mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other treatments (p<0.05). Based on the irradiation parameters considered for this study, it can be concluded that in healthy dentin, the surface treatment with Er:YAG and Er,Cr:YSGG irradiation showed bonding values lower than the control group, but they presented satisfactory results. However, in eroded dentin, the use of Er,Cr:YSGG laser, associated with the self-etching adhesive system, promoted positive effect on adhesion to composite resin.
|
9 |
Laser de Er,Cr:YSGG em condutos radiculares preparados para cimentação de núcleos protéicos / The utilization of Er,Cr:YSGG laser in prosthetic post space preparation before post placementQuinto Junior, José 19 December 2011 (has links)
O objetivo deste estudo é avaliar a influência da irradiação com laser de Er,Cr:YSGG no espaço protético de condutos radiculares preparados para a fixação de pinos em fibra de vidro reforçados (FRC Postec®), avaliando-se o comportamento de três diferentes técnicas adesivas (self-etching= Panavia F®; total-etching= Excite DSC® + Variolink II® e self-adhesive= RelyX Unicem Aplicap®). Observaram-se as orientações da norma ISO-TS 11405 para a preparação das raízes dentais unirradiculares humanas. As amostras foram separadas na altura da junção amelo-dentinaria, tratadas endodonticamente com instrumentação rotatória e seladas com técnica de condensação lateral. Foram utilizados dois tipos diferentes de pontas de safira para irradiação intracanal o axial (Z4, 400 m de diâmetro) e o radial ou side firing (RFT4, 415 m de diâmetro) com densidade de energia de 40 J/cm2. Esta densidade de energia foi obtida como parte deste experimento, analisando-se diversos parâmetros de energia com os resultados morfológicos e térmicos obtidos. Nesta densidade, obtive-se grande quantidade de túbulos dentinários abertos e variação de temperatura segura para uso clínico. Cada raiz foi irradiada em cinco movimentos circulares, de apical para cervical, com intervalo de 20 segundos, entre elas. Os FRC Postec foram cimentados imediatamente após a irradiação e divididos randomicamente em nove grupos (n=10). Cada raiz foi seccionada em 6 discos de 1 mm de espessura para ensaio do tipo push-out, para a obtenção da força máxima de ruptura, e posterior cálculo da resistência de união adesiva em função da área de superfície do núcleo deslocado, resultando na pressão em MPa. A resistência de união adesiva nos grupos irradiados foi estatisticamente superior do que os grupos controle. Foram avaliadas as diferenças na resistência de união adesiva em diferentes porções do núcleo (cervical, médio e apical), onde o sistema adesivo tipo self-adhesive (RelyX Unicem Aplicap) teve o melhor resultado para os grupos irradiados. Avaliou-se por técnica de FTIR as diferenças químicas ocorridas na dentina intrarradicular irradiada com laser de Er,Cr:YSGG, em diferentes porções (cervical, médio e apical) em função da orientação dos túbulos. Foram observadas nos espectros de FTIR alterações na intensidade das bandas de algumas moléculas, indicando variação na quantidade da parte orgânica (amida I e amida II) após a irradiação, nas diferentes regiões dentais em função do feixe laser sobre a orientação dos túbulos dentinários, sem causar alterações na sua composição. Essas diferenças podem interferir no resultado da resistência de união adesiva. A técnica de utilização de laser de Er,Cr: YSGG em dentina radicular pré-cimentação de núcleo protético aumenta a resistência de união adesiva, na dependência do cimento utilizado. / The aim of this study was to evaluate the influence of the Er,Cr:YSGG laser irradiation in the prosthetic post space before FRC Postec placement using three different adhesive systems (self-etching- Panavia F; total-etching- Excite DSC + Variolink II e self adhesive - RelyX Unicem Aplicap). According to ISO-TS 11405, sectioned at the CEJ, human dental single roots were endodontically treated with rotatory instruments and filled with gutta-percha points and sealer. Were used at 40 J/cm2 an axial Z4 laser tip (400 m diameter) and a radial (side firing) RFT4 laser tip (415 m diameter). This density of energy was experimentally determinated observing morphological changes in SEM images due to an increase range in the energy applied to dentinal root canal surface. At the length between 32 and 49 J/cm2 most of the intracanal dentinal tubules were open. The temperature increase was within the biological safe suggesting a feasible clinical use. Each root canal was irradiated five times with helicoidal movements from apical to cervical, with 20 seconds interval. FRC Postec were immediately cemented and randomly divided in nine groups (n=10). Each root canal was cut in six discs for push out test, were the maximum failure load was obtained and the bond strength was calculated as a function of post bonded area. The bond strength for the irradiated groups was superior among all control groups. The evaluation of bond strength among root region (cervical, middle and apical) was performed and differences were observed. The self-adhesive (RelyX Unicem Aplicap) system was noted superior among all irradiated groups and all regions. Chemical changes were analyzed by FTIR due to dental root portion and dentinal tubules orientation to laser beam direction. The FTIR spectra obtained indicated changes due to tubules orientation and root canal portion irradiated such as the proportion among the compositional ratio without causing chemical changes. These compositional ratio alterations may affect the bond strength results. The irradiation with Er,Cr:YSGG laser on dentinal walls of a prosthetic post space preparation before the post cementation, as suggested in this study, may increase the bond strength between the post and root canal dentin depending upon the luting cement that is used.
|
10 |
Laser de Er,Cr:YSGG em condutos radiculares preparados para cimentação de núcleos protéicos / The utilization of Er,Cr:YSGG laser in prosthetic post space preparation before post placementJosé Quinto Junior 19 December 2011 (has links)
O objetivo deste estudo é avaliar a influência da irradiação com laser de Er,Cr:YSGG no espaço protético de condutos radiculares preparados para a fixação de pinos em fibra de vidro reforçados (FRC Postec®), avaliando-se o comportamento de três diferentes técnicas adesivas (self-etching= Panavia F®; total-etching= Excite DSC® + Variolink II® e self-adhesive= RelyX Unicem Aplicap®). Observaram-se as orientações da norma ISO-TS 11405 para a preparação das raízes dentais unirradiculares humanas. As amostras foram separadas na altura da junção amelo-dentinaria, tratadas endodonticamente com instrumentação rotatória e seladas com técnica de condensação lateral. Foram utilizados dois tipos diferentes de pontas de safira para irradiação intracanal o axial (Z4, 400 m de diâmetro) e o radial ou side firing (RFT4, 415 m de diâmetro) com densidade de energia de 40 J/cm2. Esta densidade de energia foi obtida como parte deste experimento, analisando-se diversos parâmetros de energia com os resultados morfológicos e térmicos obtidos. Nesta densidade, obtive-se grande quantidade de túbulos dentinários abertos e variação de temperatura segura para uso clínico. Cada raiz foi irradiada em cinco movimentos circulares, de apical para cervical, com intervalo de 20 segundos, entre elas. Os FRC Postec foram cimentados imediatamente após a irradiação e divididos randomicamente em nove grupos (n=10). Cada raiz foi seccionada em 6 discos de 1 mm de espessura para ensaio do tipo push-out, para a obtenção da força máxima de ruptura, e posterior cálculo da resistência de união adesiva em função da área de superfície do núcleo deslocado, resultando na pressão em MPa. A resistência de união adesiva nos grupos irradiados foi estatisticamente superior do que os grupos controle. Foram avaliadas as diferenças na resistência de união adesiva em diferentes porções do núcleo (cervical, médio e apical), onde o sistema adesivo tipo self-adhesive (RelyX Unicem Aplicap) teve o melhor resultado para os grupos irradiados. Avaliou-se por técnica de FTIR as diferenças químicas ocorridas na dentina intrarradicular irradiada com laser de Er,Cr:YSGG, em diferentes porções (cervical, médio e apical) em função da orientação dos túbulos. Foram observadas nos espectros de FTIR alterações na intensidade das bandas de algumas moléculas, indicando variação na quantidade da parte orgânica (amida I e amida II) após a irradiação, nas diferentes regiões dentais em função do feixe laser sobre a orientação dos túbulos dentinários, sem causar alterações na sua composição. Essas diferenças podem interferir no resultado da resistência de união adesiva. A técnica de utilização de laser de Er,Cr: YSGG em dentina radicular pré-cimentação de núcleo protético aumenta a resistência de união adesiva, na dependência do cimento utilizado. / The aim of this study was to evaluate the influence of the Er,Cr:YSGG laser irradiation in the prosthetic post space before FRC Postec placement using three different adhesive systems (self-etching- Panavia F; total-etching- Excite DSC + Variolink II e self adhesive - RelyX Unicem Aplicap). According to ISO-TS 11405, sectioned at the CEJ, human dental single roots were endodontically treated with rotatory instruments and filled with gutta-percha points and sealer. Were used at 40 J/cm2 an axial Z4 laser tip (400 m diameter) and a radial (side firing) RFT4 laser tip (415 m diameter). This density of energy was experimentally determinated observing morphological changes in SEM images due to an increase range in the energy applied to dentinal root canal surface. At the length between 32 and 49 J/cm2 most of the intracanal dentinal tubules were open. The temperature increase was within the biological safe suggesting a feasible clinical use. Each root canal was irradiated five times with helicoidal movements from apical to cervical, with 20 seconds interval. FRC Postec were immediately cemented and randomly divided in nine groups (n=10). Each root canal was cut in six discs for push out test, were the maximum failure load was obtained and the bond strength was calculated as a function of post bonded area. The bond strength for the irradiated groups was superior among all control groups. The evaluation of bond strength among root region (cervical, middle and apical) was performed and differences were observed. The self-adhesive (RelyX Unicem Aplicap) system was noted superior among all irradiated groups and all regions. Chemical changes were analyzed by FTIR due to dental root portion and dentinal tubules orientation to laser beam direction. The FTIR spectra obtained indicated changes due to tubules orientation and root canal portion irradiated such as the proportion among the compositional ratio without causing chemical changes. These compositional ratio alterations may affect the bond strength results. The irradiation with Er,Cr:YSGG laser on dentinal walls of a prosthetic post space preparation before the post cementation, as suggested in this study, may increase the bond strength between the post and root canal dentin depending upon the luting cement that is used.
|