• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 88
  • 27
  • 25
  • 19
  • 8
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 167
  • 38
  • 29
  • 28
  • 27
  • 25
  • 23
  • 20
  • 18
  • 17
  • 17
  • 15
  • 15
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Comparação da função visual entre pacientes implantados com lentes intraoculares para a correção da presbiopia após a facoemulsificação / Comparison of visual function in patients implanted with intraocular lenses to correct presbyopia after phacoemulsification

Ferreira, Miriam Alves 14 June 2018 (has links)
Objetivo: Estudar maneiras distintas de se corrigir a presbiopia durante a facoemulsificação, através da avaliação do desempenho visual de quatro diferentes modelos de lentes intraoculares; assim como determinar a influência da pupila na recuperação visual e comparar a independência ao uso de óculos após o implante bilateral. Casuística e Métodos: Estudo prospectivo, consecutivo, randomizado que avaliou 60 pacientes (120 olhos) divididos em quatro grupos: lentes multifocais Restor +3, Restor +2.5, monovisão com a lente SN60WF e a pseudoacomodativa Crystalens XO. Foram incluídos pacientes que apresentavam catarata nuclear NI, NII ou cortical similar, que foram submetidos à avaliação oftalmológica completa no pré- operatório e com 1, 3 e 12 meses após a cirurgia. Antes do procedimento, os seguintes exames foram realizados: biometria óptica (Lenstar 900), microscopia especular, avaliação da região macular e das camadas de fibras nervosas por meio de Tomografia de Coerência Óptica (OCT), avaliação da sensibilidade ao contraste (Software Macular Mapping Test) e pupilometria dinâmica (ISCAN INC). As cirurgias foram realizadas por dois cirurgiões, em caráter ambulatorial. Durante o seguimento, nas visitas de 1, 3 e 12 meses após a cirurgia, foram realizadas medidas de acuidade visual longe e perto, mono e binocular, curva de desfoco monocular e pupilometria; e foi aplicado um questionário de satisfação baseado do Visual Functioning Questionnaire - 25 (VFQ 25), assim como medidas de sensibilidade ao contraste. Resultados: Dos 120 olhos selecionados, 114 foram operados, 106 avaliados com um mês de cirurgia, 100 com três meses e 45 pacientes (90 olhos) chegaram a última avaliação com um ano de follow-up. As médias da acuidade visual para longe sem correção binocular foram de 0,09 ± 0,04; 0,09 ± 0,03 e 0,11 ± 0,03 logMar para as lentes Restor +2.5, Restor +3 e SN60WF, respectivamente. Entre elas não se observou diferença significativa. Já para a lente Crystalens XO, a média foi de 0,24 ± 0,04 logMar, constatando-se sua inferioridade para longe de forma significativa estatisticamente em relação às demais. Este resultado foi atribuído à pobre previsibilidade refracional da lente pseudoacomodativa (-1.33 ± 1.37 dpt). Para perto, não houve diferença entre os grupos Restor +3 e monovisão, e as lentes Restor +2.5 e Crystalens apresentaram piores resultados que as duas primeiras, de forma significativa. As médias para perto, em logMar foram de 0,08 ± 0,01; 0,17 ± 0,04; 0,22 ± 0,04 e 0,23 ± 0,07 para as lentes Restor +3, SN60WF, Restor +2.5 e Crystalens, respecivamente. A curva de desfoco das lentes multifocais Restor +3 e Restor +2.5 apresentou dois picos de acuidade visual máxima; o primeiro vértice próximo a zero e o segundo em -2.5 dpt para a Restor +3 e -2 dpt para a Restor +2.5. O segundo vértice da Restor +3 foi mais acentuado em relação ao da Restor +2.5. Já o modelo Crystalens apresentou a curva de desfoco com um pico de acuidade visual máxima, semelhante às lentes monofocais SN60WF, ambas com vértice próximo ao equivalente esférico programado. A partir da curva de desfoco, somando-se as acuidades visuais entre os dois picos de melhor visão, foi criado um índice, denominado Índice de Multifocalidade. O intuito foi criar um indicador de qualidade de visão longe, intermediário e perto para as diversas lentes. O modelo Restor +3 obteve o melhorResumo índice entre as lentes estudadas, porém não mostrou diferença significativa em relação à Restor +2.5, que, por sua vez, não evidenciou diferença quanto à Crystalens. A lente SN60WF teve o pior índice. Já em relação a pupila, não houve interferência de sua amplitude de contração no pré-operatório com as acuidades visuais longe e perto após a cirurgia. Contudo, o tamanho da pupila contraída demonstrou correlação com o índice de multifocalidade. A avaliação da sensibilidade a estímulos de baixo contraste (10%) no campo visual central (8 graus) não foi diferente entre os grupos, tanto no pré quanto no pós-operatório. E em relação à presença de halos e glare, os grupos Restor +3 e +2.5 apresentaram incidência de 26% e 43%, respectivamente; já no grupo SN60WF não houve relato. A satisfação com a performance visual para longe foi de 78% no grupo Crystalens, 80% no grupo monovisão e 90% para as multifocais Restor +3 e Restor +2.5. Para perto, 100 % dos usuários da Restor +3, 80% da monovisão, e 50% dos grupos Restor +2.5 e Crystalens estavam satisfeitos. Finalmente, entre as maneiras distintas de se corrigir a presbiopia na facoemulsificação, o grupo Restor +3 atingiu 93% de independência do uso de óculos após a cirurgia. Inesperadamente e de acordo com os resultados, o modelo Restor +2.5 demonstrou baixa probabilidade de independência (14%). Para a monovisão e Crystalens, 30% e 50%, respectivamente. Conclusões: Tanto a lente multifocal Restor +3 quanto a monovisão com a SN60WF foram eficazes de forma semelhante na correção da presbiopia, porém o modelo Restor +3 proporcionou maior probabilidade de independência ao uso de óculos. Os modelos Restor +2.5 e a Crystalens XO pseudoacomodativa foram inferiores que as duas primeiras, pela lente multifocal Restor +2.5 apresentar resultados aquém do previsto para perto, com baixa independência do uso de óculos; e a Crystalens mostrar imprevisibilidade refracional biométrica, comprometendo a visão de longe dos usuários. A respeito da dinâmica pupilar, as medidas do pré e pós-operatório não evidenciaram interferência no desempenho visual das lentes multifocais, monovisão e pseudoacomodativa; exceto no índice de multifocalidade, onde as pupilas contraídas apresentaram correlação com os resultados. / Objective: Study different ways of correcting presbyopia in phacoemulsification by comparing visual performance of four different models of intraocular lenses; as well as to determine the influence of the pupil on visual recovery and to compare the independence of glasses after bilateral implant. Casuistic and Methods: Prospective, consecutive, randomized study with 60 patients (120 eyes) divided into 4 groups: Restor +3 and Restor +2.5 multifocal lenses, monovision with SN60WF and Crystalens XO pseudoacommodative lens. Patients who had nuclear NI, NII or similar cortical cataract were submitted to a complete ophthalmologic evaluation in the preoperative period and at 1,3 and 12 months after surgery. Before procedure, the following tests were performed: optical biometry (Lenstar 900), specular microscopy, analyse of macular region and nerve fiber layers with Optical Coherence Tomography (OCT), contrast sensitivity (MMTest Software) and pupilometry dynamics (ISCAN INC). Surgeries were performed by two surgeons. During the follow-up, visits of 1, 3 and 12 months were measured far and near, mono and binocular visual acuity, defocous curve, pupilometry, satisfaction questionnaire was applied based on Visual Functioning Questionnaire - 25 (VFQ 25) as well as a contrast sensitivity measurements (Macular Mapping Test). Results: Of the 120 eyes selected, 114 were operated, 106 were evaluated at 1 month of surgery, 100 at 3 months, and 45 pacients (90 eyes) achieve the last evaluation at 1 year follow-up. The mean visual acuity for far without binocular correction was 0.09 ± 0.04; 0.09 ± 0.03 and 0.11 ± 0.03 logMar for the lenses Restor +2.5, Restor +3 and SN60WF respectively. Between them there was no difference. For the Crystalens XO lens, the mean was 0.24 ± 0.04 logMar, showing its inferiority statistically significantly different than the others. This result was attributed by the poor refractive predictability of the pseudoacommodative lens (-1.33 ± 1.37 dpt). For close, there was no difference between the Restor +3 and monovision groups, and the Restor +2.5 and Crystalens lenses were worse than the first with statistical significance . The means for near were 0,08 ± 0,01; 0.17 ± 0.04; 0.22 ± 0.04 and 0.23 ± 0.07 for the Restor +3, SN60WF-, Restor +2.5 and Crystalens lenses. The defocous curve of the multifocal lenses Restor +3 and Restor +2.5 had 2 peaks of maximum visual acuity, the first in zero and the second close to -2.5 dpt for Restor +3 and -2 dpt for Restor +2.5. The second vertex of Restor +3 was more pronounced than Restor +2.5. The Crystalens group presented a defocous curve with only 1 peak of maximum visual acuity, as well as the SN60WF monofocal lenses, both with a vertex near the programmed spherical equivalent. From the defocous curve, adding the visual acuity between the two best view peaks, an index was created, called Multifocality Index. The aim was to create a far, intermediate and close quality index for the various lenses. Restor +3 obtained the best index, but that was no significantly different than Restor +2.5, which had no difference with Crystalens. SN60WF achieved the worst index. Regarding the pupil, did no notice interference of its preoperative contraction amplitude with the visual acuities far and near after the surgery. However, the size of contracted pupil had a statistically significant correlation with the multifocality index. The sensitivity to low contrastAbstract stimuli (10%) in the central visual field (8 degrees) was no different between the groups, both in the pre and postoperative periods. About presence of halos and glare, the multifocal lenses Restor +3 and Restor +2.5 showed 26% and 43% respectively. No cases were reportaded with model SN60WF. The satisfaction with the far visual performance was 78% in the Crystalens group, 80% for monovision and 90% in the multifocal lenses Restor +3 and +2.5. For near, 100% of Restor +3 users, 80% of monovision, and 50% of Restor +2.5 and Crystalens groups were satisfied. Finally, among the distinct ways of correcting presbyopia in phacoemulsification, the Restor +3 group showed that 93% of their users achieved independence of the glasses after surgery. Unexpectedly and according to the visual results, the Restor +2.5 model showed a low probability of independence, 14%. For monovision and Crystalens, 30% and 50% respectively. Conclusions: Both Restor +3 and monovision with SN60WF were similarly effective for correction of presbyopia, but the Restor +3 model provides a greater probability of independence from wearing glasses. The Restor +2.5 and pseudoacommodative models Crystalens XO were worst than the first two, because the multifocal Restor +2.5 presented results below the predicted for near, with low independence of the use of glasses; and model Crystalens unexpected biometric refractive unpredictability, compromising the view from far away from users. Regarding the pupillary dynamics, the pre and postoperative measurements showed no interference in the visual performance of multifocal, monovision and pseudoacommodative lenses; except in the multifocality index, where pupils contracted had a correlation with the results.
32

Estudio instrumental de la respuesta inflamatoria en la cirugía de la catarata

Sayans Gómez, Juan Ángel 08 March 1996 (has links)
No description available.
33

Uma contribuição para circuitos eletrônicos de medidores de radiações ultravioleta para lentes / A contribution to electronic circuits of ultraviolet radiation meters lens

Oliveira, Gunter Camilo Dablas de 07 August 2009 (has links)
O propósito deste trabalho foi o desenvolvimento de um sistema para medir a transmissão das radiações no intervalo 290nm - 380nm, em lentes oftálmicas. O protótipo é um dispositivo opto-eletrônico, composto por uma fonte de ultravioleta; dois sensores de radiação - UVA e UVB (fotodiodos); um circuito eletrônico para a realização das medidas e um mostrador para fornecer o resultado. Quando o sistema é ligado, a fonte emite a radiação ultravioleta, e os dois sensores captam os respectivos sinais, no intervalo de UVA e UVB e armazenam estes dados. Ao se colocar uma lente para ser testada, os sensores recebem novamente o sinal e dividem pelo sinal armazenado, fornecendo assim, a porcentagem de luz ultravioleta transmitida pela lente. Os sinais provenientes dos fotodiodos são amplificados de modo que transformam uma baixa corrente em tensão (na faixa de milivolts), que por sua vez é amplificada para um fundo de escala com tensão máxima igual a 5VCC. O sinal obtido na saída dos amplificadores é enviado para um conversor analógico digital (A/D); o sinal digital é enviado para um microcontrolador AT89S52, que foi programado para ler dados do conversor A/D, ler teclas e proporcionar o laudo escrito em um display. Polarizadores calibradores e lentes de óculos foram testados no sistema desenvolvido e as medidas comparadas com o espectro de transmissão em um espectrofotômetro Cary 17 - VARIAN. O fator de correlação entre os dois sistemas foi de 0,82. O circuito digital apresenta uma imprecisão menor do 1% nas medidas. Isto tem a implicação direta no fator de correlação entre este protótipo e o espectrofotômetro. As flutuações da lâmpada também contribuem para a imprecisão, uma vez que a repetibilidade do sistema é de 90%, em 20 medidas de uma mesma lente. Sendo assim, este protótipo é capaz de medir a proteção ultravioleta em lentes de óculos, com uma precisão de 2%. Modificações do sistema serão implementadas no futuro, para que medidas com precisão de 0,5% sejam atendidas, em protótipo para uso clínico. / The purpose of this work is the development of a system for measuring the transmission of radiation at 290nm - 380nm range of ophthalmic spectacles. The prototype is an optoelectronic device, assembled by ultraviolet radiation source; two ultraviolet sensors UVA and UVB (photodiodes); an electronic circuit and a display, as a user interface, for providing the reports. As the illumination system is turned on, the sensors receive their respective voltage signals, at the UVA and UVB range, and store the data. As a spectacle is placed for testing, the sensors collect the data from the signal and divide them by the previous data stored, providing the percentage of ultraviolet radiation transmitted by the spectacles. The electronic signals delivered by the photodiodes are amplified in order to convert a low intensity current into voltage (order of milivolts), which is then amplified into a 5Vcc scale. The output voltage of the amplifiers is sent to na A/D converter; the digital signal is sent to a microcontroller AT89S52, which is then programmed for reading the data of the converter; reading the keyboard and providing the report on a display. Calibrating polarizers and spectacles have been tested in the developed system and the data have been compared to the transmission spectrum of a spectrophotometer Cary 17 - VARIAN. The correlation factor was 0.82. The electronic digital circuit presents an error lesser than 1%. This has a straight relation on the correlation factor between the prototype and the spectrophotometer. Output fluctuations of the light source add extra inaccuracy on the system, since the repetitivity of the measurements is 90%, for 20 measurements of the same spectacle. Hence, the prototype is capable of measuring the ultraviolet protection of spectacles, with a 2% precision. Modifications on the system should be implemented in a near future, in order to provide 0.5% accuracy, and then be released for clinical use.
34

O aglomerado de galáxias RXC J1504 - 0248 / The Galaxy Cluster RXC J1507 048

Soja, Ana Cecilia 30 November 2011 (has links)
O objetivo deste trabalho foi determinar a massa do aglomerado de galáxias RXC J1504-0248, localizado em z = 0.215, através da análise de lentes fracas, e comparar os resultados com aqueles obtidos em trabalhos anteriores através da análise de raios-X. Imagens do aglomerado foram obtidos nas bandas r\', g\' e i\' com o detector GMOS do telescópio Gemini Sul. A partir dessas imagens, contruímos um catálogo de objetos no campo usando o software Sextractor (SE) (Bertin e Arnouts, 1996). Este software também foi utilizado para classificá-los como galáxias ou estrelas. Foram identificadas 172 galáxias neste campo, que também foram detectadas no Data Release 7 do Sloan Digital Sky Survey (SDSS). Estas galáxias foram então usadas para obter uma calibração fotométrica das imagens, comparando as magnitudes instrumentais e do SDSS nas mesmas bandas. Após a calibração fotométrica, e através da comparação com imagens do CFHTLS obtidas em cores semelhantes, as galáxias foram classificadas como membros de cluster, foreground ou background, a partir de sua posição nos diagramas cor-cor e cor-magnitude. A reconstrução da massa do aglomerado através da análise de lentes gravitacionais foi realizada em duas etapas. Na primeira, foi utilizado o software IM2SHAPE, desenvolvido por Bridle et al. (1998), que modela os objetos, adicionando até três gaussianas, cada uma definida por seis parâmetros: as coordenadas do centro do objeto, x0 e y0, a elipticidade e, o ângulo de posição , o produto dos semi-eixos maior e menor ab, e a amplitude A. Inicialmente, o programa foi executado apenas para as estrelas do campo, com o objetivo de se obter uma estimativa da distribuição da PSF. A estimativa foi então utilizado como entrada para a análise das galáxias. Na segunda etapa, para estimar a massa do aglomerado foi utilizado o programa LENSENT, desenvolvido por Marshall et al. (2002), cujos parâmetros de entrada são a elipticidade das galáxias de fundo e seus erros. Na técnica de lentes gravitacionais fracas, a dependência radial da deformação das galáxias de fundo permite determinar o perfil de massa do aglomerado. Para estimar a massa, ajustamos um perfil de uma Esfera Isotérmica Singular (SIS, na sigla em inglês), e determinamos o valor da massa dentro de um raio de 3Mpc, 1.3 ± 0.6 x 10¹ Msol. O resultado é consistente com o obtido por Bohringer et al., 2005, 1.7 x 10¹ Msol, através da análise em raios-X. Comparando o mapa de distribuição de luminosidade e da emissão de raios-X concluímos que eles são muito semelhantes à distribuição superficial de massa, resultado que indica equilíbrio. / In this work we studied the galaxy cluster RXC J1504-0248, at z=0.215, from images in the bands r\', g\' and i\' obtained with Gemini South telescope. The photometric calibration was performed by comparison with field objects identified in the Sloan Digital Sky Survey (SDSS). From the analysis of color-color and color-magnitude diagrams, galaxies in the field were then divided into cluster members, background and foreground objects. We determined the PSF using the IM2SHAPE program \\cite{Bridle98}. These results enabled us to obtain the cluster projected mass distribution through a weak lensing analysis performed with the LENSENT program \\cite{Marshall02}. We also shown that the cluster luminosity distribution and the X-ray emission are consistent with the mass map. Using a SIS model, we estimated the mass of the cluster, obtaining 1.3 x 10¹ Msun, consistent with the mass obtained in a previous X-ray analysis, 1.7 x 10¹ Msun, by \\cite{Bohringer05}.
35

Uma contribuição para circuitos eletrônicos de medidores de radiações ultravioleta para lentes / A contribution to electronic circuits of ultraviolet radiation meters lens

Gunter Camilo Dablas de Oliveira 07 August 2009 (has links)
O propósito deste trabalho foi o desenvolvimento de um sistema para medir a transmissão das radiações no intervalo 290nm - 380nm, em lentes oftálmicas. O protótipo é um dispositivo opto-eletrônico, composto por uma fonte de ultravioleta; dois sensores de radiação - UVA e UVB (fotodiodos); um circuito eletrônico para a realização das medidas e um mostrador para fornecer o resultado. Quando o sistema é ligado, a fonte emite a radiação ultravioleta, e os dois sensores captam os respectivos sinais, no intervalo de UVA e UVB e armazenam estes dados. Ao se colocar uma lente para ser testada, os sensores recebem novamente o sinal e dividem pelo sinal armazenado, fornecendo assim, a porcentagem de luz ultravioleta transmitida pela lente. Os sinais provenientes dos fotodiodos são amplificados de modo que transformam uma baixa corrente em tensão (na faixa de milivolts), que por sua vez é amplificada para um fundo de escala com tensão máxima igual a 5VCC. O sinal obtido na saída dos amplificadores é enviado para um conversor analógico digital (A/D); o sinal digital é enviado para um microcontrolador AT89S52, que foi programado para ler dados do conversor A/D, ler teclas e proporcionar o laudo escrito em um display. Polarizadores calibradores e lentes de óculos foram testados no sistema desenvolvido e as medidas comparadas com o espectro de transmissão em um espectrofotômetro Cary 17 - VARIAN. O fator de correlação entre os dois sistemas foi de 0,82. O circuito digital apresenta uma imprecisão menor do 1% nas medidas. Isto tem a implicação direta no fator de correlação entre este protótipo e o espectrofotômetro. As flutuações da lâmpada também contribuem para a imprecisão, uma vez que a repetibilidade do sistema é de 90%, em 20 medidas de uma mesma lente. Sendo assim, este protótipo é capaz de medir a proteção ultravioleta em lentes de óculos, com uma precisão de 2%. Modificações do sistema serão implementadas no futuro, para que medidas com precisão de 0,5% sejam atendidas, em protótipo para uso clínico. / The purpose of this work is the development of a system for measuring the transmission of radiation at 290nm - 380nm range of ophthalmic spectacles. The prototype is an optoelectronic device, assembled by ultraviolet radiation source; two ultraviolet sensors UVA and UVB (photodiodes); an electronic circuit and a display, as a user interface, for providing the reports. As the illumination system is turned on, the sensors receive their respective voltage signals, at the UVA and UVB range, and store the data. As a spectacle is placed for testing, the sensors collect the data from the signal and divide them by the previous data stored, providing the percentage of ultraviolet radiation transmitted by the spectacles. The electronic signals delivered by the photodiodes are amplified in order to convert a low intensity current into voltage (order of milivolts), which is then amplified into a 5Vcc scale. The output voltage of the amplifiers is sent to na A/D converter; the digital signal is sent to a microcontroller AT89S52, which is then programmed for reading the data of the converter; reading the keyboard and providing the report on a display. Calibrating polarizers and spectacles have been tested in the developed system and the data have been compared to the transmission spectrum of a spectrophotometer Cary 17 - VARIAN. The correlation factor was 0.82. The electronic digital circuit presents an error lesser than 1%. This has a straight relation on the correlation factor between the prototype and the spectrophotometer. Output fluctuations of the light source add extra inaccuracy on the system, since the repetitivity of the measurements is 90%, for 20 measurements of the same spectacle. Hence, the prototype is capable of measuring the ultraviolet protection of spectacles, with a 2% precision. Modifications on the system should be implemented in a near future, in order to provide 0.5% accuracy, and then be released for clinical use.
36

Efeito da magnificação na postura de trabalho em odontologia /

Wajngarten, Danielle. January 2018 (has links)
Orientador: Patrícia Petromilli Nordi Sasso Garcia / Resumo: Este trabalho teve como objetivo observar o efeito da magnificação na postura de trabalho durante a realização de procedimentos odontológicos. Para isso, propôs-se a realização de sete estudos. Os estudos 1 e 2 tiveram como objetivo revisar a literatura para reunir informações disponíveis em torno da magnificação e ergonomia e da magnificação em endodontia, respectivamente. No estudo 3, foi realizada a observação da acuidade visual de estudantes de odontologia (N=160) em função de cinco diferentes condições visuais (olho nu, visão com lupa simples, visão com lupa do sistema Galilean, visão com lupa do sistema Keplerian e microscópio operatório) e em duas distâncias de trabalho (de 35cm boca/olhos e confortável para o operador). Além disso, os desvios angulares de pescoço foram registrados por meio de tomadas fotográficas. A acuidade visual foi medida através de uma tabela de E-optótipos localizados em cavidades Classe I de molares superiores. O desvio angular foi mensurado por meio do Software de Análise Postural. Realizou-se análise estatística descritiva e Análise de Variância - ANOVA a qual foi conduzida de forma independente para os diferentes anos do curso (2°, 3°, 4° e 5°). O nível de significância adotado para tomada de decisão foi de 5%. Observou-se interação significativa para o sistema de magnificação e distância (p<0,05) em todos os anos, tanto para a acuidade visual quanto para o ângulo de pescoço. Para a distância padronizada e em todos os anos do curso, a maior ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to observe the magnification effect on work posture during dental procedures. For this, seven studies were conducted. The studies 1 and 2 aimed to review the literature in order to gather informations regarding to magnification and ergonomics and magnification in endodontics, respectively. Study 3 aimed to determine dental students' visual acuity and neck angulation when using magnification devices and distances from the operating field. Forty students from each of the second through fifth years of the five-year program at the School of Dentistry of Araraquara were selected (N=160). Visual acuity was tested using a miniature Snellen eye chart under five different settings (unaided vision; simple loupe; Galilean loupe; Keplerian loupe and an operating microscope). Photographs were taken during the visual acuity exam in order to evaluate the angulation of the subjects' necks in a neutral posture. The two-factor Analysis of Variance - ANOVA and the Games-Howell post-hoc test were performed for the different years of the course (α=0.05). A significant difference in visual acuity and neck angulation was found between the "magnification device" and "distance" factors in each of the graduating classes analyzed (p<0.05). At a standardized distance, the Keplerian loupe, the Galilean loupe and the operating microscope provided the greatest visual acuity. At a subjectively comfortable distance, the Keplerian and Galilean loupes produced the best visual acuity. Regarding... (Complete abstract click electronic access below) / Doutor
37

Videonistagmoscopia digital com lente de contato para identifica??o de movimentos oculares e apoio ao topodiagn?stico da vertigem posicional parox?stica benigna

Grossi, Rafaeli Sagrilo 29 April 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-10-10T17:13:24Z No. of bitstreams: 1 DIS_RAFAELI_SAGRILO_GROSSI_PARCIAL.pdf: 731531 bytes, checksum: 2a61d4b51ae149bd92ef4ac8256b7072 (MD5) / Made available in DSpace on 2016-10-10T17:13:24Z (GMT). No. of bitstreams: 1 DIS_RAFAELI_SAGRILO_GROSSI_PARCIAL.pdf: 731531 bytes, checksum: 2a61d4b51ae149bd92ef4ac8256b7072 (MD5) Previous issue date: 2016-04-29 / Benign paroxysmal positional vertigo (BPPV) is characterized by vertigo crisis, triggered by sudden head position changes, associated with the appearance of paroxysmal positional nystagmus. The characterization of torsional nystagmus has fundamental importance while conducting a patient with BPPV, because it turns possible to identify the affected semicircular channel, as well as the physiopathological mechanism involved. However, the majority of existing videonystagmography devices are not capable of identifying these torsional movements with the required precision. This work aims to develop and test a method to model and identify torsional eye movements, when present. This new model uses a videonystagmograph prototype, comercial ophthalmic contact lens with geometric figures and a computer program, which was specially designed with this objective. Complementarily, a webapp program has also been created to support the topodiagnosis of the BPPV. Subjects with BPPV and without BPPV have been evaluated. The subjects have undergone the Dix-Hallpike maneuver, using the contact lens with geometrical figures on the left eye and the capture device. Among these evaluations, forty videos have been recorded (23 with counter-clockwise rotating movement phenomena, 10 clockwise and 7 videos with eye at rest). The extracted videos were analyzed with the developed software. The success rate in classifying the direction of the rotating movement (counter-clockwise or clockwise) and the resting position was evaluated. The accuracy of the software in correctly finding the geometric lines of the ophthalmic lens was also evaluated. Among the forty analyzed videos, the software had a success rate of 85% (70-94%) in identifying direction of movement or at rest; considering only the success rate in direction of movement, the total was 81% (64-93%). The accuracy in the measuring of the interest zone of the frames was 82,2% (81,5-82,8%) with p<0,05 significance level. Therefore, the new developed model should be able to have an important part on the topodiagnosis of the BPPV in the future, providing a more precise and effective therapeutic management to the patients with this disease. / A vertigem posicional parox?stica benigna (VPPB) ? caracterizada por crises de vertigem, desencadeadas por mudan?as bruscas de posi??o da cabe?a, associada a um nistagmo posicional parox?stico. A caracteriza??o do nistagmo rotacional ? de fundamental import?ncia na condu??o do paciente com VPPB, pois ? atrav?s das caracter?sticas do nistagmo que ? poss?vel identificar o canal semicircular acometido, bem como o mecanismo fisiopatol?gico envolvido. Por?m, a maioria dos dispositivos de videonistagmoscopia existentes n?o s?o capazes de identificar com precis?o esses movimentos rotat?rios. A proposta deste trabalho foi desenvolver e testar um novo modelo de quantifica??o de movimentos oculares rotat?rios quando presentes. Este novo modelo utiliza prot?tipo de videonistagmosc?pio, lente de contato oft?lmica comercial com figuras geom?tricas e o desenvolvimento de um software especificamente para esta finalidade. De forma complementar, uma WebApp tamb?m foi criada para auxiliar no topodiagn?stico da VPPB. Participaram do estudo 4 indiv?duos com VPPB e 4 sem VPPB. Os sujeitos foram submetidos ? manobra de Dix-Hallpike, utilizando a lente de contato com formas geom?tricas no olho esquerdo e o dispositivo de captura. Dessas manobras, foram gravados 40 v?deos (23 com fen?menos de movimento rotat?rio anti-hor?rio, 10 no sentido hor?rio e 7 v?deos com olho em repouso). Os v?deos extra?dos foram analisados com o software criado. Foi analisada a taxa de acertos na classifica??o da dire??o do fen?meno de movimento rotat?rio (anti-hor?rio ou hor?rio) quando presente ou v?deo repouso. Tamb?m foi avaliada acur?cia do software em encontrar corretamente as marcas geom?tricas da lente oft?lmica. Dos 40 v?deos analisados, o software obteve como taxa de acerto da dire??o ou repouso valor de 85% (70-94%); considerando-se apenas a taxa de acerto da dire??o, o valor foi de 81% (64-93%). A acur?cia na medida da zona de interesse dos frames foi de 82,2% (81,5-82,8%) com n?vel de signific?ncia de p<0,05. Assim, o novo modelo desenvolvido poder? no futuro ter um papel importante no aux?lio do topodiagn?stico da VPPB, proporcionando aos doentes com esta enfermidade um manejo terap?utico mais preciso e eficaz.
38

Modélisation et optimisation sur cycle d'une génératrice doublement saillante faible vitesse de rotation pour hydrolienne. / Modeling and optimization of a low speed doubly salient permanent magnet machine for tidal application

Alli, Soklni-Sita 28 June 2019 (has links)
Cette étude traite d’une machine doublement saillante à aimants permanents, utilisée en entraînement direct pour application hydrolienne. Dans un premier temps, différentes approches technologiques utilisées pour l’exploitation hydrolienne sont passées en revue. Ensuite, la génératrice est modélisée par approche circuit. Cette méthode permet de tenir compte de la saturation magnétique et de la variation d’entrefer, tout en offrant un compromis intéressant entre la précision des résultats et le temps de simulation. Le modèle de la DSPM est ensuite couplé avec son convertisseur. Un modèle thermique est également mis en place. Ce modèle est ensuite utilisé pour optimiser simultanément la denture de la DSPM et les paramètres de la commande afin de maximiser le couple et de réduire ses ondulations, importantes dans les machines à saillance. Les paramètres de commande sont également optimisés sur un cycle hydrolien. Le premier critère à minimiser sur cycle concerne les ondulations de couple. Les pertes Joule sont ensuite rajoutées comme second critère. Des fronts de Pareto sont alors déduits et analysés. Finalement, des essais à vide et en charge sur un prototype 2 kW, 50 tr/min ont permis de valider le modèle théorique développé. / This study deals with a doubly salient permanent magnet machine, used in direct drive for tidal application. First, different technological approaches used for tidal power generation are reviewed. Then, the generator is modelled by circuit approach. This method allows for magnetic saturation and airgap variation to be taken into account, while offering an interesting compromise between the accuracy of the results and the simulation time. The DSPM model is then coupled with its converter. A thermal model is also implemented. This model is then used to optimize simultaneously the DSPM teeth and its control parameters in order to maximize the torque and reduce its ripples which are important in salient machines. The control parameters are also optimized on a tidal cycle. The first criterion to be minimized on cycle is the torque ripples. Joule losses are added as a second criterion and Pareto fronts are deduced and analyzed. Finally, tests at no-load and also at load operations on a prototype 2 kW, 50 rpm validate the theoretical model developed
39

Uso de biópticos (ICL y Lasik) para la corrección de la alta miopía

Puig Galy, Javier José 16 May 2001 (has links)
OBJETIVOS: Determinar la eficacia, predictibilidad, estabilidad y seguridad de la cirugía refractiva mediante "Biópticos" (combinación del implante de una lente fáquica de cámara posterior y láser in situ queratomileusis) en pacientes afectos de altas miopías.Describir el procedimiento quirúrgico y mostrar los resultados visuales y refractivos del mismo.MATERIAL Y MÉTODOS:Hemos analizado 102 ojos de 63 pacientes afectos de alta miopía, intervenidos mediante el implante de una lente fáquica de cámara posterior tipo ICLTM y láser in situ queratomileusis (Lasik).El seguimiento postoperatorio medio fue de 19 meses (rango: 12-36 meses).RESULTADOS:El equivalente esférico medio preoperatorio fue de -18,20 ± 4,21 D., con un astigmatismo medio asociado de -1,87 ± 1,57 D. La media aritmética del equivalente esférico tras implantar la lente fáquica y antes de realizar el Lasik fue de -2,59 ± 2,04 D. El equivalente esférico medio tras el procedimiento Bióptico completo resultó ser de -0,28 ± 0,33 D., con un cilindro medio de -0,53 ± 0,35 D.El 100% de los pacientes se encontraban postoperatoriamente en el rango de ± 1,00 D. respecto a la emetropía, mientras el 95,09% lo hacían en el rango de ± 0,50 D.Las refracciones postoperatorias se mantuvieron estables durante los sucesivos controles, sin cambios estadísticamente significativos.La agudeza visual sin corrección mejoró en todos los casos. La agudeza visual corregida se mantuvo igual o mejoró postoperatoriamente en todos los casos excepto en dos. La media de ganancia de agudeza visual corregida postoperatoria fue de dos líneas de Snellen.Todos los pacientes se mostraron muy satisfechos con los resultados obtenidos.DISCUSIÓN:El uso combinado de lentes fáquicas de cámara posterior tipo ICLTM y Láser in situ queratomileusis (Lasik) constituye un método efectivo y predecible para corregir la alta miopía.Es frecuente la mejoría postoperatoria de la agudeza visual corregida de estos pacientes. Los resultados muestran una considerable seguridad del procedimiento a corto y medio plazo, así como una gran estabilidad refractiva. / PURPOSE: To determine the efficacy, predictability, stability and safety of "Bioptics" refractive surgery (combined posterior chamber phakic intraocular lens implantation and laser in situ keratomileusis) in eyes with extreme myopia. To report the technique and to assess the results (refraction and visual acuity) of this surgical procedure.MATERIAL AND METHODS: We analyzed the results of 102 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (ICLTM) and also underwent secondary Lasik for the correction of extreme myopia. Mean follow-up was 19 months after the Lasik procedure (range 12 to 36 months).RESULTS: Mean preoperative spherical equivalent refraction was -18,20 ± 4,21 D., and mean refractive cylinder was -1,87 ± 1,57 D. Mean spherical equivalent refraction after IOL implantation and before Lasik was -2,59 ± 2,04 D. Mean postoperative spherical equivalent refraction one year after the Lasik portion of the double Bioptics procedure was -0,28 ± 0,33 D., and mean refractive cylinder was -0,53 ± 0,35 D.One hundred percent were within ± 1,00 D. and 95,09 % were within ± 0,50 D. of emmetropia at last examination.The refractions remained stable with a statistically insignificant change during follow-up.Uncorrected visual acuity improved in all cases. Best spectacle-corrected acuity remained the same or improved in all but two cases. Mean best spectacle-corrected acuity gain after the double procedure was two Snellen lines.Patient satisfaction with the final visual outcome was very high.CONCLUSIONS: Combined posterior chamber phakic IOL implantation with ICLTM lens and Lasik (Bioptics) is an effective and reasonably predictable method for correcting high myopia. Gains in spectacle-corrected visual acuity were common, and results demonstrated good short-medium term safety and refractive stability.
40

Lentes intraoculares para ojo fáquico de fijación iridiana para la corrección de defectos de la refracción

Morral i Palau, Mercè 18 February 2009 (has links)
El implante de lentes intraoculares (LIOs) para ojo fáquico ha experimentado una creciente popularidad en los últimos años, hasta el punto de convertirse en la técnica de elección para la corrección de defectos refractivos moderados-severos por la mayor parte de cirujanos refractivos. A diferencia de la cirugía láser sobre la córnea o de la cirugía del cristalino, la corrección de ametropías moderadas-severas mediante LIOs fáquicas consigue una mejor calidad óptica, a la vez que permite mantener la acomodación y afinar defectos refractivos residuales mediante cirugía corneal mínima. Además, se trata de un procedimiento relativamente reversible, ya que es posible extraer la lente en caso de no adaptación a la corrección o de presentarse algún efecto indeseado. Han existido en el mercado diversos modelos de LIOs fáquicas pero sólo dos de ellos han sido aprovados por la FDA ('Food and Drug Administration'). La primera LIO fáquica en aprovarse fue la lente de fijación iridiana Artisan® - Verisyse® como alternativa a la cirugía láser para disminuir o eliminar miopía de -5.0 a -20.0 dioptrías en adultos de edad igual o superior a 21 años, en septiembre del 2004. Los estudios multicéntricos europeo y de la FDA nos muestran datos de eficacia y seguridad a los 2 y 3 años de seguimiento tras la cirugía. Sin embargo, no existen datos a largo plazo, con la excepción del seguimiento de 10 años de Tahzib y cols. de lentes Artisan® para miopía. Sólo un mayor tiempo de seguimiento nos permitirá asegurar que la presencia de estas lentes dentro del ojo no sólo es efectiva, sino también segura.Nuestros datos tras 5 años de seguimiento de 399 ojos muestran que la LIO fáquica de fijación iridiana Artisan®/Verisyse® es un procedimiento efectivo y seguro para la corrección de defectos de la refracción moderados-severos, incluyendo miopía, hipermetropía y/o astigmatismo.La comparación de dos tipos diferentes de LIOs fáquicas de cámara anterior, la lente Acrysof (lente plegable de apoyo angular) y la lente Artisan®/Verisyse® (lente rígida de fijación iridiana), no mostró diferencias significativas en cuanto a eficacia y seguridad, excepto en el astigmatismo inducido por la cirugía en los tres primeros meses del postoperatorio. Ambos tipos de lentes mostraron un excelente perfil de eficacia y seguridad tras 5 años de seguimiento. Finalmente, realizamos un estudio dinámico durante la acomodación mediante tomografía de coherencia óptica de segmento anterior (Visante), mostrando la relación entre estas lentes con las estructuras intraoculares, que nos proporciona una mayor comprensión de las potenciales complicaciones a largo plazo. / In recent years, phakic intraocular lens (PIOL) implantation has gained increased popularity. Nowadays, most refractive surgeons consider it the procedure of choice to correct moderate-to-high ammetropias. Compared with corneal ablation techniques and clear lens extraction, the implantation of PIOLs is believed to provide better optical quality, maintenance of accommodation and fine-tuning of the refractive result by minimal corneal refractive surgery. Moreover, it is a relatively reversible procedure, as the PIOL may be taken out in case complications occur. The first PIOL to gain FDA approval was the iris-claw Artisan®/Verisyse®, which was approved in September 2004 for the correction of myopia ranging -5 to -20 diopters in adults older than 21 years-old. European multicenter and FDA studies show efficacy and safety data at 2 and 3 years of follow-up. However, there is a lack of longer term follow-up data, with the exception of Tahzib's et al. studies 10 years after implantation. To stablish the efficacy and safety of any procedure, long-term follow-up data is essential. After 5 years, Artisan®/Verisyse® PIOL implantation has shown excellent efficacy and safety for the correction of moderate-to-high ammetropias, including myopia, hyperopia and/or astigmatism in a series of 399 eyes. We have compared two different types of anterior chamber PIOLs, the Acrysof (foldable, angle-supported PIOL) and the Artisan®/Verisyse® (rigid, iris-claw PIOL). No significant differences concerning efficacy and safety were found, except for surgical induced astigmatism the first 3 postoperative months. Both PIOLs showed excellent efficacy and safety profiles after 5 years. Finally, dynamic accommodation studies using anterior segment optical coherence tomography has provided unvaluable insights of the relation between iris-claw PIOLs and intraocular structures that may explain potential long-term complications.

Page generated in 0.0349 seconds