• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da liga de aluminio-zinco como filtração alternativa para a radiação X

Haiter, Claudia 15 December 2000 (has links)
Orientação: Frab Norberto Boscolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T14:26:03Z (GMT). No. of bitstreams: 1 Haiter_Claudia_M.pdf: 3563481 bytes, checksum: 0f8631489485e0a3818bb5e6539a19e8 (MD5) Previous issue date: 2000 / Resumo: O objetivo deste trabalho foi avaliar os efeitos da filtração alternativa da liga alumínio/zinco em aparelhos de raios X odontológicos, em relação ao espectro de energia dos feixes de raios X, a taxa de kerma no ar, o índice de contraste nas radiografias obtidas e qualidade das imagens radiográficas. Este estudo foi realizado comparando o filtro convencional de alumínio com várias espessuras do filtro de liga alumínio/zinco, em diferentes porcentagens do elemento zinco na liga (2%, 3%, 4% e 5%). Foi utilizado um aparelho de raios X odontológico convencional, operando com 60 kVp e 70 kVp, e filmes radiográficos pertencentes ao grupo D e E de sensibilidade. Foram realizadas radiografias de um "phantom" e de uma escala de densidade de alumínio. O uso dos filtros de liga AI/Zn resultou em um não endurecimento dos feixes. A taxa de kerma no ar diminuiu em até 18,53%, sem alteração no contraste das radiografias. A qualidade das imagens obtidas com os filtros de liga AIZn também tiveram uma boa aceitação pelos examinadores. A análise dos resultados nos levou a concluir que o filtro de liga AIZn 2%, com 1,99 mm de espessura, tensão de 60 kVp, quando usado com filme D, foi o que obteve melhor desempenho, reduzindo a taxa de kerma no ar sem variar o índice de contraste das radiografias, mantendo a qualidade da imagem aceitável para diagnóstico, sem contudo aumentar o tempo de exposição / Abstract: The aim of this research was evaluate the effects of the alternative filtration of the aluminumlzinc alloy in dental X rays machines, in relation to the spectrum of energy , the X ray dose, the contrast alterations and the image quality. This study was accomplished comparing the conventional aluminum filter with several thickness of the aluminumlzinc alloy filter, in different percentages of zinc in the alloy (2%, 3%, 4% and 5%). It was used a conventional X ray machine, operating with 60 kVp and 70 kVp, and D and E speed films, in order to obtain images of a phantom and of a aluminum step wedge. The use of the filters Al/Zn resulted in a spectra with smaller amount of fótons, however it was not found hardening of the beam. The kerma in the air was decreased in up to 18,53%, without alteration in the contrast of the images. The quality of the images obtained with the filters Al/Zn also had a good acceptance for the examiners. The analysis of the results showed that the filter alloy Al/Zn 2%, with 1,99 mm of thickness, tension of 60 kVp, when used with film D, obtained the best performance, reducing the kerma in the air without reducing contrast, and the image quality was considered acceptable for diagnosis. This filter also didn't needed an increase in the exposition time that would cause an consequent increase in the load of the tube / Mestrado / Mestre em Radiologia Odontológica
2

Estudo da viabilidade técnica do processo de fabricação de espumas metálicas por reciclagem de cavacos da liga AA356 / Study of the technical viability of the fabrication process of metal foams by means of AA356 alloy machined chips recycling

Ribeiro, Daniel Tadeu de Carvalho 08 November 2018 (has links)
Orientador: Maria Helena Robert / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-11-08T18:35:02Z (GMT). No. of bitstreams: 1 Ribeiro_DanielTadeudeCarvalho_M.pdf: 21302819 bytes, checksum: 8a7a0a9d878be3b8ccb6833173c35aef (MD5) Previous issue date: 2011 / Resumo: Este trabalho tem como objetivo desenvolver um método alternativo para a fabricação de espumas metálicas pela reciclagem de cavacos de Al e a caracterização mecânico-metalúrgica do produto obtido. O processo investigado envolve a espumagem de compactados de misturas de cavacos e pó de agente espumante, com a espumagem ocorrendo na liga em estado semi-sólido tixotrópico. Foram fabricados precursores espumáveis pela mistura de cavacos da liga de Al AA356, com duas distintas granulometrias, a 1,5wt% do agente espumante TiH2 e posterior compressão também em duas distintas condições: compressão simples a frio e compressão dupla, a frio e a quente. Os elementos precursores foram aquecidos, sofrendo espumagem em estado semi-sólido, pela dissociação do agente espumante formando gás H2 no interior do metal. As espumas metálicas produzidas foram analisadas quanto à sua qualidade interna, arquitetura celular (dimensões, geometria de poros, espessura de paredes metálicas), propriedades físicas (densidade, teor de porosidade, condutividade e difusividade térmicas) e mecânicas em compressão semi-estática. O comportamento mecânico em compressão e o comportamento térmico das espumas produzidas foram também estimados teoricamente utilizando modelos da literatura. Os resultados obtidos mostraram que o processo proposto é eficaz para a produção de espumas de boa qualidade. Os melhores resultados são obtidos com o emprego de compactação dupla e espumagem direcional do precursor. Não foi possível observar influência das dimensões dos cavacos utilizados, na faixa de tamanhos empregada, nas características e propriedades das espumas produzidas. O comportamento das espumas metálicas sob compressão semi-estática demonstrou a formação de um platô de deformação plástica ascendente, o que indica uma grande capacidade de absorção de energia mecânica; todas as amostras apresentaram condutividade térmica bastante inferior e difusividade superior à do metal maciço, representando boas propriedades isolantes térmicas. Os valores de propriedades mecânicas estimadas teoricamente diferem dos obtidos experimentalmente, indicando necessidade de cuidado no emprego destes modelos / Abstract: This work aims to develop an alternative method for manufacturing metal foams by Al alloy machined chips recycling and mechanical and metallurgical characterization of the product. The process investigated involves foaming a compressed mixture of Al chips and foaming agent powder, with foaming occurring with the alloy in semi-solid thixotropic state. Foamable precursors were manufactured by mixing Al alloy A356 machined chips in two different particle sizes, to 1.5 wt% of the foaming agent TiH2 and its posterior compression also in two distinct conditions: simple cold compression and double compression, cold and hot. The precursors were heated, being foamed in semisolid state, by dissociation of the foaming agent generationg H2 into the bath. The internal quality, cellular architecture (pore size and geometry, cell wall thickness), physical properties (density, porosity level, thermal conductivity and thermal diffusivity) and mechanical behaviour under semi-static compression were analyzed for the metal foams produced. The mechanical behavior under compression and thermal behavior of the foams produced were also calculated using theorical models from literature. The results showed that the procedure proposed is effective for the production of foams of good quality. The best results are obtained foaming directionaly precursors manufactured by double compression. It was not possible to observe the influence of the dimensions of the machined chips, considering the size range adopted, on the characteristics and properties of the foams produced. The mechanical behavior of metallic foams under semi-static compression showed the formation of a ascendent plateau of plastic deformation, which indicates a great capacity of absorbing mechanical energy; all samples showed significantly lower thermal conductivity and diffusivity compared to the solid metal, what represents good thermal insulation properties. The theorical estimative of the sample's mechanical properties differ from those obtained experimentally, indicating that the matematical models proposed has to be used carefully / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
3

[pt] AVALIAÇÃO DA PREVISÃO DE VIDA DE PEÇAS ENTALHADAS SOB CARGAS DE AMPLITUDE VARIÁVEL / [en] EVALUATION OF FATIGUE LIFE PREDICTION OF SPECIMEN WITH STRESS FACTOR CONCENTRATION UNDER VARIABLE AMPLITUDE LOADING

KALLIN DE SOUZA 30 April 2020 (has links)
[pt] O método EN baseia-se na quantificação do dano causado pela deformação decorrente do histórico de carregamento. O objetivo desse modelo consiste em estimar o número de ciclos para iniciar uma trinca por fadiga. Diferente do método SN o número de variáveis envolvidas nesse modelo é menor. Entretanto, requer um número maior de constantes, que nem sempre podem ser obtidas experimentalmente. Esse fato levou a formulação de diversos modelos que se propõem a estimar as constantes de Coffin-Manson, que na maioria dos casos levam a previsões de vida não conservativas, como visto em outros trabalhos. Contudo a maioria dos casos existentes na literatura não abordam o efeito de regiões de concentração de tensão e a influência de carregamentos com amplitudes variáveis. A metodologia usada nessas pesquisas consiste em avaliar a influência desses aspectos através da comparação entre a vida em fadiga experimental e a estimada segundo as constantes de Coffin-Manson medidas e estimadas segundo diferentes modelos. Esse estudo avalia o dano à fadiga segundo 2 tipos de concentradores de tensão e quatro históricos de carregamentos de amplitude variável. Considerando os modelos de Manson, Muralindhran-Manson, Bäumel-Seeger and Meggiolaro-Castro os resultados mostram que a vida em fadiga prevista usando os parâmetros de Coffin Manson obtidos segundo o método de Meggiolado-Castro e por Baumel-Segger são os que mais se aproximam das vidas estimadas baseada nas constantes experimentais. Nos demais casos nota-se que a regra de concentração de tensão exerce uma maior influência no resultado e levam a vidas à fadiga não conservativas. / [en] The strain-life designed is based on the damaged caused by the strain as a result of a loading history. The purpose of this approach is estimating the number of cycles to initiate a fatigue crack. Compared with the stress life method the EN needs a lower number of variables. However, it needs a large number of parameters that are not directly measurable properties of a material and conduct the necessary number of tests to obtain them is not always an option. This fact leads to the formulation of different models to estimate Coffin- Manson s constants, which in most of the cases can result in a non-conservative fatigue life prediction, as seen in several papers. However, in these studies, it is not considered a specimen with a stress concentration factor neither under a variable amplitude loading history. The methodology used in this research is evaluating the influence of these aspects by comparing the fatigue life experimental with the estimated by using the Coffin Manson s experimental constants and the fatigue life calculated with different models to estimate the Coffin-Manson s parameters. This study evaluated the fatigue damage based on four load histories and two types of samples with different stress risers. Considering the models of Manson, Muralidharan-Manson, Bäumel-Seeger, and Meggiolaro-Castro the results indicated that the fatigue life predicted using the Coffin Manson s parameter obtained by Meggiolaro-Castro and Baumel-Segger s model are more similar to the life calculated with the experimental constants. The other models are more influenced by the stress concentration s rule and can lead to not conservative fatigue life.

Page generated in 0.0616 seconds