• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 644
  • 29
  • 11
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 694
  • 273
  • 256
  • 170
  • 162
  • 117
  • 113
  • 89
  • 86
  • 80
  • 69
  • 66
  • 65
  • 63
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Identificação de perigos na recapacitação de linhas de transmissão

Fernando Teixeira Vilela, Rômulo January 2001 (has links)
Made available in DSpace on 2014-06-12T17:41:23Z (GMT). No. of bitstreams: 2 arquivo7314_1.pdf: 1496321 bytes, checksum: 304d79be1477dc551a4e016581e51f4a (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2001 / Este trabalho tem o objetivo de mostrar a aplicabilidade para a recapacitação de linhas transmissão com a técnica de feixe expandido, da ferramenta de identificação de perigos, que utiliza os diagramas lógicos semigráficos, chamados de, continuos value network - CVN e single value network - SVN, originariamente desenvolvida para o gerenciamento dos riscos de incêndio em edificações, pelo Prof. Robert Fitzgerald da Wochester Polytecnic Institute. A ferramenta que utiliza as CVN e SVN, é perfeitamente capaz de identificar os perigos na construção para recapacitar linhas de transmissão com a técnica de feixe expandido, além disso, tem uma forma de comunicar, tanto aos envolvidos no processo quanto ao decisor, os perigos e o conjunto de soluções de ações para o gerenciamento dos riscos, tão bem quanto as ferramentas que utilizam diagramas lógicos recomendadas internacionalmente que são as árvores de eventos , de modos de falhas e diagramas de causa e consequência. No capítulo 1, é feito uma apresentação da teoria da recapacitação de linhas de transmissão com a técnica de feixe expandido, originalmente proposta pelo Prof. George Alexandrov da Universidade de Leningrado. No capítulo 2, é apresentado o processo em seus detalhes para se construir a recapacitação de um tramo de trabalho da linha de transmissão da Companhia Hidroelétrica do São Francisco - CHESF que vai de Paulo Afonso na Bahia até Milagres no Ceará.(LT PAF/BNO/MLG). No capítulo 3, é apresentada a adaptação da ferramenta para a identificação qualitativa dos perigos na construção para recapacitação de um tramo de trabalho com a técnica de feixe expandido da LT PAF/BNO/MLG. No capítulo 4, mostramos que através da edução do conhecimento a priori de especialistas sobre a ocorrência dos riscos identificados no capítulo 3, damos um tratamento quantitativo e associando os critérios tempo e custo, sugerimos a construção de um sistema de decisão multicritério para que o decisor possa gerenciar os riscos do empreendimento. Concluímos no capítulo 5, que a adaptação da ferramenta usando as CVN/SVN é viável e que gerenciar os riscos do empreendimento de recapacitar a LT PAF/BNO/MLG é importante para a redução de custos e impactos ambientais o que contribui para aumentar a oferta de energia elétrica, auxiliando no desenvolvimento. Apresentamos também sugestões para futuros trabalhos no sentido de se melhorar a edução e de como se combinar as opiniões de vários especialistas
52

TPM nas linhas finais de montagem

Sousa, Carlos Miguel Ferreira de January 2009 (has links)
Estágio realizado na Bosch Termotecnologia, S. A. e orientado pelo Eng.º Tiago Melo Sacchetti / Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2009
53

Modelo de abastecimento de materiais à produção

Fernandes, Agostinho Leandro de Teixeira January 2011 (has links)
Tese de mestrado integrado. Engenharia Industrial e Gestão. Faculdade de Engenharia. Universidade do Porto. 2010
54

Caracterização do desempenho das linhas aéreas da RNT

Soares, José Joaquim Gonçalves January 2008 (has links)
Estágio realizado na Rede Eléctrica Nacional e orientado pela Eng.ª Susana Almeida / Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores - Major Energia. Faculdade de Engenharia. Universidade do Porto. 2008
55

Estabelecimento de uma relação entre as actuações das protecções existentes nas linhas aéreas e a ocorrência de incidentes de origem atmosférica

Lopes, Daniel Henrique Pereira January 2009 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores (Major Energia). Faculdade de Engenharia. Universidade do Porto. 2009
56

Avaliação de vulnerabilidades e riscos fluviais para a reabilitação de um troço de um rio ou ribeira : estudo da Ribeira da Certagem

Vinagre, Tiago Luís de Mil-Homens e January 2008 (has links)
Tese de mestrado integrado. Engenharia Civil (especialização em Hidráulica). Faculdade de Engenharia. Universidade do Porto. 2008
57

Desempenho termico de cabos de potencia subterraneos incluindo migração de umidade no solo e efeitos transientes

Freitas, Daniel Santana de January 1995 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnologico / Made available in DSpace on 2016-01-08T19:20:38Z (GMT). No. of bitstreams: 1 99782.pdf: 3763925 bytes, checksum: 7639140bf252d46abece9dab7fc84eb2 (MD5) Previous issue date: 1995 / Apresentação de uma metodologia numérica para a simulação de transferência de calor e migração de umidade em solos úmidos em torno de cabos elétricos de potência em instalações subterrânea. O solo circundante aos cabos é modelado de acordo com a abordagem do contínuo para meios porosos insaturados. As equações governantes resultantes deste processo são resolvidas de acordo com a metodologia de volumes finitos. O código computacional resultante é otimizado de modo a evitar os longos tempos computacionais normalmente associados a este tipo de simulação, permitindo a obtenção de resultados completos em computadores de pequeno porte. Para aproximar a solução obtida das necessidades reais dos projetistas de cabos elétricos subterrâneos, que necessitam a temperatura no núcleo do cabo, o interior do cabo também é incorporado à formulação do problema. O modelo físico do solo é o mais completo possível, dentro dos limites impostos pelo tempo computacional, e inclui a depedência de todas as propriedades com umidade e temperatura, além de fatores adicionais como o efeito de gravidade sobre a umidade do solo e um modelo simplificado para o efeito de histerese das curvas que descrevem as propriedades termo-hidráulicas do solo.
58

Requisitos legais observados na análise da viabilidade ambiental de empreendimentos sujeitos ao licenciamento ambiental federal no Brasil

Zanette, Tatiana Maria January 2016 (has links)
Dissertação (mestrado profissional) - Universidade Federal de Santa Catarina, Centro de Ciências Biológicas, Programa de Pós-Graduação em Perícias Criminais Ambientais, Florianópolis, 2016. / Made available in DSpace on 2017-01-03T03:14:20Z (GMT). No. of bitstreams: 1 343198.pdf: 841584 bytes, checksum: dc43bfb64a35fc6b32008401a5cacdf2 (MD5) Previous issue date: 2016 / Este trabalho buscou identificar e avaliar se os requisitos mínimos previstos na legislação ambiental foram contemplados na análise dos estudos e demais documentos presentes no processo de licenciamento ambiental dos empreendimentos de linhas de transmissão de energia elétrica, licenciados pelo IBAMA, entre os anos de 2014 e 2015, com a finalidade de subsidiar o processo decisório de emissão de licença prévia. As amostras dessa pesquisa consistiram nos pareceres técnicos que serviram como subsídio para a tomada de decisão sobre a emissão das licenças prévias. Foram analisados 30 pareceres técnicos no âmbito de 18 processos de licenciamento ambiental. Ficou evidente que requisitos consolidados no âmbito dos estudos ambientais no Brasil tiveram 100% de atendimento, como: contemplar alternativas locacionais; identificar e avaliar os impactos; definir limites da área de influência; elaborar diagnóstico das áreas de influência incluindo meios físico, biótico e socioeconômico; definir medidas mitigadoras e elaborar programas de acompanhamento e monitoramento. No entanto, outros requisitos tiveram 0% de atendimento, como: confrontar todas as alternativas com a hipótese de não execução de projeto; análise dos impactos das alternativas; verificação da competência dos profissionais responsáveis pela elaboração do estudo. Nas amostras que analisaram EIA, não houve manifestação dos órgãos gestores de unidades de conservação nas 6 amostras em que continha a informação de que o empreendimento causaria intervenção em Unidade de Conservação. Quanto a manifestação dos intervenientes FUNAI, IPHAN, Fundação Cultural Palmares e Ministério da Saúde, nos processos que analisaram EIA o percentual de atendimento foi de 62,5% enquanto que nas amostras que analisaram RAS o percentual de atendimento foi de 25%. Constatou-se que nenhuma amostra atendeu plenamente todos os requisitos legais consultados nesta pesquisa. Ainda assim, a emissão da Licença Prévia foi recomendada em 17 processos.<br> / Abstract : The objective of this case was to identify and to evaluate if environmental legal requirements were observed of environmental viability analysis in the federal licensing process of the transmission electric energy lines in 2014 and 2015. The samples of this research was the technical advice. We analyzed 30 technical advice in the 18 environmental licensing processes. consolidated requirements under the environmental studies in Brazil had 100% compliance: locational alternatives; identify and assess the impacts; to define areas of influence; elaborate diagnosis of the areas of influence including physical, biotic and socio-economic means; define mitigation measures and control and monitoring programs. However, other requirements had 0% coverage, such as: confronting all alternatives with the hypothesis not project execution; analysis of the impacts of the alternatives; verification of the competence of the professionals responsible for preparing the study. In the samples that analyzed EIA, there was no manifestation of the management of protected areas in 6 samples that contained the information that the project would cause intervention in protected areas. As the manifestation of FUNAI, IPHAN, Fundação Cultural Palmares and the Ministry of Health, in the processes that analyzed EIA the compliance was 62.5% while in the samples analyzed RAS the compliance was 25%. No samples met all legal requirements surveyed in this study. However, the issuance of the preliminary environmental license was recommended in 17 cases.
59

Análise no plano alfa da proteção diferencial de linhas de transmissão com compensação série

Diniz, Olaia Pinheiro 30 June 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-09-26T16:02:58Z No. of bitstreams: 1 2016_OlaiaPinheiroDiniz.pdf: 3322237 bytes, checksum: 2200088b7f631041e40894975be872d7 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-01-10T16:02:45Z (GMT) No. of bitstreams: 1 2016_OlaiaPinheiroDiniz.pdf: 3322237 bytes, checksum: 2200088b7f631041e40894975be872d7 (MD5) / Made available in DSpace on 2017-01-10T16:02:45Z (GMT). No. of bitstreams: 1 2016_OlaiaPinheiroDiniz.pdf: 3322237 bytes, checksum: 2200088b7f631041e40894975be872d7 (MD5) / Apresenta-se nesta dissertação de mestrado a análise do desempenho da proteção diferencial de linhas de transmissão com compensação série implementada considerando-se a característica de restrição modificada do plano alfa (plano-α). Para tanto, são considerados os elementos diferenciais de fase, assim como os de sequência negativa e zero. Utilizando-se do software Alternative Transients Program (ATP), são apresentadas as modelagens de dois sistemas elétricos de potência de 500 kV. O primeiro sistema é constituído de dois equivalentes de Thévenin conectados por uma linha de transmissão de 400 km com compensação série instalada em ambas as extremidades. O segundo, fornecido pela Eletrobras Eletronorte, representa uma parte do sistema interligado nacional (SIN), no qual avalia-se a linha de transmissão circuito 2 (C2) compensada de 387 km do circuito duplo existente entre as subestações de Imperatriz e Presidente Dutra, no estado do Maranhão (Brasil, MA). Com o propósito de se obter modelos mais fidedignos para os sistemas utilizados, a linguagem MODELS do ATP foi implementada nos esquemas de proteção dos bancos de capacitores série constituídos da combinação de um varistor de óxido metálico, do inglês Metal Oxide Varistor (MOV), a um centelhador auto-induzido, do inglês Spark GAP, juntamente com um circuito RL amortecedor. Os centelhadores são controlados através de lógicas de disparo que se baseiam nos valores de corrente medidos e energia absorvida pelo MOV. As simulações apresentadas compreendem análises das respostas transitórias de alguns curtos-circuitos, bem como a sensibilidade paramétrica do sistema diante da variação de dois parâmetros de curto-circuito através das simulações em massa realizadas. Portanto, a fim de dar subsídios para o melhor entendimento da proteção diferencial de linhas de transmissão com compensação série, este trabalho evidencia interessantes análises do comportamento das trajetórias dos quocientes diferenciais no plano-α, principalmente em relação à influência da atuação da proteção dos bancos, inclusive diante de algumas variações paramétricas efetuadas. ________________________________________________________________________________________________ ABSTRACT / This master thesis presents the performance of the differential protection function applied to transmission lines with series compensation, implemented through a modified restraint characteristic on the alpha plane (α-plane). For this purpose, both phase and sequence differential elements are evaluated. By using the Alternative Transients Program (ATP), it is presented the modeling of two 500 kV power electrical systems. The first system consists of two equivalent Thevenin connected by a transmission line 400 km long with series compensation installed at both ends. The second one is provided by Eletrobras Eletronorte and represents a part of the Brazilian interconnected system, in which the evaluated equipment is the compensated transmission line named as 2nd circuit (C2) 387 km long from the existing double circuit between the Imperatriz and Presidente Dutra substations, in the state of Maranhão (Brazil, MA). In order to obtain more reliable designs for the used systems, the ATP MODELS language is implemented in the protection schemes of the series capacitor banks consisting of a combination of a metal oxide varistor (MOV), a self-induced spark GAP, along with an RL damping circuit. The spark GAP is controlled by trigger logics which are based on the measured current values and the energy absorved by the MOV. The simulations presented covers transient response analysis for some short circuits as well as the system parametric sensitivity by means of the variation of two short-circuit parameters through the obtained mass simulations. Therefore, in order to accomplish a better understanding about the series compensated transmission line differential protection, this master thesis shows interesting analysis of the behavior of the differential quotient trajectories in the α-plane, especially in relation to the effect due to the operated series capacitor banks protection, including through some parametric variations simulated.
60

Influência da corrente capacitiva de linhas de transmissão no desempenho da função de proteção de distância

Silva, Suellen Paula de Oliveira 13 April 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-08-28T18:05:26Z No. of bitstreams: 1 2018_SuellenPauladeOliveiraSilva.pdf: 4269013 bytes, checksum: 52b77fa5ead03964d6ede229146eb8b8 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-08-31T19:42:15Z (GMT) No. of bitstreams: 1 2018_SuellenPauladeOliveiraSilva.pdf: 4269013 bytes, checksum: 52b77fa5ead03964d6ede229146eb8b8 (MD5) / Made available in DSpace on 2018-08-31T19:42:15Z (GMT). No. of bitstreams: 1 2018_SuellenPauladeOliveiraSilva.pdf: 4269013 bytes, checksum: 52b77fa5ead03964d6ede229146eb8b8 (MD5) Previous issue date: 2018-08-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / Esta dissertação apresenta a avaliação do desempenho de estratégias de mitigação do efeito da corrente capacitiva de linhas de transmissão no desempenho da proteção de distância. Para tanto, foram avaliados dois algoritmos propostos na literatura sobre o assunto. O primeiro é baseado no modelo de linha longa, também denominado de modelo π equivalente ou π exato, enquanto o segundo baseia-se em capacitâncias concentradas nos terminais da linha (modelo π nominal). Seus desempenhos foram comparados com o da tradicional formulação de proteção de distância. O Programa de Alternative Transients Program (ATP) foi utilizado para modelar uma linha de transmissão de 60 Hz / 500 kV de 200 km de comprimento, em que foram simuladas uma grande variedade de faltas. Os desempenhos dos algoritmos são avaliados utilizando a análise de sensibilidade paramétrica, na qual apenas parâmetro muda o valor a cada vez, proporcionando uma compreensão mais ampla da relação entre cada parâmetro e o desempenho dos algoritmos. Para fazer isso, a análise foi realizada usando a resposta dos algoritmos durante o regime permanente de curto-circuito. Os resultados obtidos revelam que as estratégias alternativas não levam a melhorias significativas para o cenário avaliado neste trabalho, de modo que a formulação tradicional ainda é a solução mais simples e robusta para a proteção de distância de linhas de transmissão. / This master thesis presents the performance evaluation of alternative strategies to mitigate the capacitive current effect of transmission lines on distance protection. In order to do so, two algorithms reported in the literature on the subject were evaluated. The first one is based on the π -equivalent line model, whereas the second one uses lumped capacitance (πnominal model). Their performances have been compared with the one of traditional distance protection formulation. The Alternative Transients Program (ATP) was used to model a 60 Hz/500 kV transmission line 200 km long, in which a wide variety of faults were simulated. The performances of the algorithms are evaluated by using parametric sensitivity analysis, thereby only one parameter value changes at a time, providing a more comprehensive understanding of the relationship between each parameter and the performance of the algorithms. In order to do so, the analysis was carried out using the response of the algorithms during the fault steady-state regime. The obtained results reveal that the alternative strategies do not lead to significant improvements for the scenario evaluated in this work, such that the traditional formulation is still the simpler and more robust solution to distance protection of transmission lines.

Page generated in 0.0399 seconds