• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 210
  • 6
  • 4
  • Tagged with
  • 223
  • 223
  • 120
  • 87
  • 62
  • 56
  • 49
  • 48
  • 42
  • 41
  • 37
  • 31
  • 29
  • 28
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Inclusão do efeito corona em modelos de linhas de transmissão bifásica utilizando a técnica de variáveis de estado

Wedy, Germano Ferreira [UNESP] 27 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-27Bitstream added on 2014-06-13T19:26:19Z : No. of bitstreams: 1 wedy_gf_me_ilha.pdf: 790523 bytes, checksum: 8836dfe828e124530d6a988987704e3f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste projeto é o desenvolvimento de um modelo de linha de transmissão bifásica diretamente no domínio do tempo, que leve em consideração o efeito corona e o efeito da freqüência sobre seus parâmetros longitudinais, utilizando os conceitos de variáveis de estado. Os parâmetros longitudinais de uma linha de transmissão dependentes da freqüência serão sintetizados por meio de funções racionais pelo método do Vector Fitting. Em seguida, as funções racionais que descrevem o comportamento dos parâmetros longitudinais serão associadas com um circuito elétrico equivalente, que será inserido em cada um dos circuitos . Para a validação do modelo desenvolvido levando em consideração o efeito da freqüência o mesmo foi comparado com o programa de estudo de transitórios eletromagnético Micotran do tipo EMTP. Utilizando o modelo matemático desenvolvido foi possível inserir através das equações de Gary e de Skilling-Umoto, o efeito corona nas simulações de transitórios eletromagnético. Ao termino do projeto, apresenta-se um modelo matemático de uma linha de transmissão que leva em conta o efeito da freqüência e o efeito corona. Tal modelo não necessita dos programas do tipo EMTP para simulação de transitórios em linhas de transmissão. / The objective of this work is to implement a computational model of two-phase transmission line directly in the time domain, which takes into account the corona effect and the effect of frequency on its longitudinal parameters, using the concepts of state variables. The longitudinal parameters of a frequency dependent transmission line are synthesized by rational functions using the Vector Fitting method. Then, the rational functions that describe the behavior of the longitudinal parameters will be associated with an equivalent electrical circuit, which is inserted in very circuit . Validating the model developed taking into account the effect of frequency, this model was compared to the Micotran program, a EMTP (Electromagnetic Transient Program) type program that is used for transient analyses in electrical networks. Through the developed mathematical model, it enter, through the equations of Gary and Skilling-Umoto, the corona effect in simulations of electromagnetic transients. At the end of the project, it is obtained a mathematical model of a transmission line that takes into account the effect of frequency and the corona effect. This model does not need the EMTP type programs for transient simulations in transmission lines.
182

Modelagem de um relé de distância em um simulador digital em tempo real.

COSTA, Cecília Alves Buriti da. 04 May 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-05-04T18:35:38Z No. of bitstreams: 1 CECÍLIA ALVES BURITI DA COSTA – DISSERTAÇÃO (PPGEE) 2016.pdf: 2848486 bytes, checksum: eb2cfb57825ecee909a3560f654a3038 (MD5) / Made available in DSpace on 2018-05-04T18:35:38Z (GMT). No. of bitstreams: 1 CECÍLIA ALVES BURITI DA COSTA – DISSERTAÇÃO (PPGEE) 2016.pdf: 2848486 bytes, checksum: eb2cfb57825ecee909a3560f654a3038 (MD5) Previous issue date: 2016-08-25 / Capes / Este trabalho apresenta o processo de modelagem de um relé de distância em um simulador digital em tempo real. O modelo inclui: i) as principais funcionalidades da arquitetura de um relé digital, incluindo filtro anti-aliasing e estimação fasorial; ii) as características de operação do tipo mho e quadrilateral, ambas com duas zonas de atuação; iii) a etapa de diagnóstico de falta, que informa as principais características do distúrbio. Para o diagnóstico da falta, foram avaliados métodos de detecção, classificação e localização por meio de simulação em massa de diferentes cenários de falta em uma linha de transmissão. Dos resultados obtidos, os melhores métodos de cada etapa foram escolhidos para compor o relé. Ao final, a atuação e o diagnóstico do relé modelado foram comparados com os resultados fornecidos pelo relé de distância disponível no próprio simulador e por um relé digital real. / This work presents the modeling process of a distance relay in a real-time digital simulator. The model contains: i) the main features of a digital relay architecture, including anti-aliasing filter and phasor estimation; ii) mho and quadrilateral operating characteristics, with two protection zones; iii) fault diagnosis, which informs the main features of the disturbance. For the fault diagnosis, detection, classification and location methods were evaluated using batch mode simulation of different fault scenarios in a transmission line. From the obtained results, the best methods were selected to be part of the modeled relay. At the end, the operation and diagnosis of the modeled relay were compared with the results presented by the distance relay model provided by the simulator manufacturer and by a digital relay.
183

A power line detection algorithm to support a fine grain UAV movement guidance

Wieczorek, Italo de Avila January 2017 (has links)
Detecção de linhas de alta tensão em ambientes complexos é uma das tarefas mais desafiadoras em inspeções que utilizam Veículos Aéreos Não Tripulados (VANTs). Este trabalho foca em dar uma solução para este desafio, através do desenvolvimento de um algoritmo de controle de voo de precisão, que guie o VANT de maneira autônoma sobre as linhas de alta tensão. O algoritmo proposto é baseado em quatro etapas: Captura da Imagem, Filtragem da Imagem, Detecção das Linhas e Controle de Voo. Inicialmente a imagem é redimensionada para um tamanho em que as linhas fiquem em maior evidência, depois uma sequência de filtros é aplicada na imagem para reduzir ruído e evidenciar ainda mais as linhas. Depois deste pré-tratamento, um filtro de duas dimensões com formato similar ao de uma linha de alta tensão é usado para extrair os pixels pertencentes as bordas destas linhas. Após a aplicação do filtro de duas dimensões, a Transformada de Hough é aplicada na imagem resultante para detectar os segmentos de reta. Por fim, todos os dados obtidos no processamento da imagem são utilizados para guiar o VANT de maneira autônoma pelas linhas de transmissão. O algoritmo proposto apresenta um eficiente sistema de detecção de linhas de alta tensão, para auxiliar o controle de voo autônomo de um VANT, apresentando resultados convincentes. / Power lines detection in complex environments is one of the most important and challenging tasks in Unmanned Aerial Vehicles (UAV)-based inspections. This work focuses on tackling this challenge by developing a control algorithm to support fine grain UAV control to autonomously guide the aerial platform over the power lines. The proposed algorithm is based on four stages: Image Capturing, Image Filtering, Line Detection and Flight Control. Firstly, the image is cropped to a size that fits all the power lines, then a sequence of filters is applied in the image to reduce noise and highlight these lines. After all the image's pretreatment, a 2D filter with similar shape of a power transmission line is used to extract pixels that belongs to the line's edges. Then, the Hough Transform method detects the line segments in the edges result image. Lastly all the obtained data is used to autonomously guide a UAV over the power transmission lines. The proposed algorithm presents an efficient power transmission lines detecting system to support the autonomous UAV guidance, which presents convincing results.
184

Diagnóstico de faltas em sistemas de subtransmissão : uma formulação baseada na Transformada Wavelet contínua

Iurinic, Leonardo Ulises January 2012 (has links)
As faltas podem ocorrer em diversos componentes de um sistema elétrico de potência, dentre os quais as linhas de transmissão se destacam como elementos susceptíveis. Devido a suas dimensões físicas, ambiente de operação e interconexão com outros sistemas, a localização exata de uma falta em uma linha de transmissão não é trivial dificultando a tarefa das equipes de manutenção para recomposição do fornecimento de energia. Neste contexto, este trabalho apresenta uma metodologia computacional desenvolvida em ambiente MATLAB® para diagnóstico de faltas em linhas de transmissão baseada na análise de transitórios de alta freqüência nas tensões do sistema. A abordagem desenvolvida neste trabalho inicialmente utiliza a equação de Park para achar a tensão zero, direta e em quadratura e posteriormente detectar a ocorrência da falta através do coeficiente de diferenças. Posteriormente, a teoria de ondas viajantes associada à transformada wavelet contínua são utilizadas objetivando determinar a frequência característica do sinal transitório, a qual é relacionada com o local da falta. Para validar o algoritmo de localização proposto foram realizadas diversas simulações de faltas com o programa ATP (Alternative Transient Program) utilizando dados de uma linha aérea real. A efetividade da abordagem proposta foi avaliada considerando a resistência de falta, o ângulo de incidência da falta e a impedância de curto-circuito do sistema. Os resultados promissores demonstraram a aplicabilidade da formulação proposta para localização faltas em linhas de transmissão aéreas utilizando medições oscilográficas digitais de apenas um terminal. / Faults can occur in several components of an electric power system, among which the transmission line stands out. Due to its physical dimensions, operating environment and interconnection systems, the exact transmission line fault location is non-trivial hindering maintenance crew system restoration. In this context, this work presents a computational methodology developed in MATLAB® environment for fault diagnosis on transmission lines based on voltage high frequency transient analysis. Thus, the approach adopted in this work use firstly the Park equations to find the zero, direct and quadrature voltage and then detect the fault occurrence through the difference coefficient. After, the traveling wave theory associated with continuous wavelet transform application is used for determining the characteristic frequency of the transient signal, which is correlated with the fault location. To validate the proposed fault location algorithm, several fault simulations were executed using ATP software using real overhead line data. The proposed fault location scheme performance was evaluated considering the fault resistance, inception fault angle and short-circuit impedance of the system. The promising results demonstrate the applicability of the proposed formulation for fault location in overhead transmission lines, using one terminal digital oscillographic measurement.
185

Contribuição ao estudo de análise de aterramento impulsivo e em altas frequências associado à avaliação da suportabilidade dos seres humanos com base no método da modelagem por linhas de transmissão (TLM)

Gazzana, Daniel da Silva January 2012 (has links)
Este trabalho fundamenta-se no desenvolvimento e aprimoramento de metodologias para a melhor representação do aterramento elétrico sob uma análise transiente. O estudo concentrase no estabelecimento de contribuições ao estado da arte associadas à análise e modelagem de aterramento impulsivo e em altas frequências. O estudo vincula-se também à avaliação da suportabilidade de seres humanos submetidos a potenciais produzidos na superfície do solo, provenientes da corrente elétrica gerada por um surto atmosférico. A concepção das metodologias propostas baseou-se no uso do Método da Modelagem por Linhas de Transmissão em uma dimensão (TLM-1D). Destacam-se três grandes tópicos da pesquisa. O primeiro concentra-se no desenvolvimento de formulação para a inclusão do fenômeno de ionização do solo ao Método TLM-1D clássico. A formulação desenvolvida tem como característica ser uma técnica generalista, independente das propriedades do meio, dimensões do eletrodo e do surto atmosférico. O segundo foco concentra-se no aprimoramento e desenvolvimento de equacionamento analítico para a estimação de potenciais gerados na superfície do solo, originados pela corrente elétrica estabelecida sobre eletrodo de aterramento. Tal equacionamento tem grande aplicabilidade em conjunto com metodologias numéricas unidimensionais, as quais não são capazes de determinar diretamente os referidos potenciais. Por fim, a realização de estudo de suportabilidade e segurança de seres humanos em contato com eletrodos de aterramento submetidos a surto atmosférico, considerando modelo representativo baseado em circuitos elétricos, consolida o trabalho desenvolvido. / This work is based on the development and improvement of methodologies for the best representation of the electrical grounding under a transient analysis. The study concentrated on establishing contributions to the state of the art related to the analysis and modeling of impulsive and high frequencies grounding systems. The study is also associated to the evaluation of the supportability of human beings submitted to the potentials produced on the soil surface from the electric current generated by a lightning. The conception of the proposed methodology was based on the Transmission Line Modeling Method in one dimension (TLM- 1D). Three major research topics can be highlighted. The first involves the development of a formulation to include the soil ionization phenomenon in the classic TLM-1D algorithm. The developed formulation is a generalist technique, independent of the medium properties, characteristic of the electrode and lightning surge. The second aims at the improvement and development of analytical equations for estimating the generated potential on the soil surface, originated by the electric current calculated in the grounding electrode. Such equationing has great applicability in conjunction with one-dimensional numerical methods which are not able to determine such potential directly. Finally, the achievement of a supportability study and personal safety of humans in contact with the grounding electrodes subjected to a lightning, considering a representative model based on electrical circuits, consolidates the developed work.
186

Análise dinâmica da ruptura de cabos em torres autoportantes e estaiadas de linhas de transmissão / Dynamic analysis of broken conductor in lattice self-supported and guyed towers of overhead transmission lines

Bentes, Jennefer Lavor January 2013 (has links)
Dentre as possíveis causas na falha da transmissão de energia elétrica, o colapso de torres de linhas de transmissão (LTs) é uma problemática amplamente investigada nas últimas décadas, devido principalmente aos inúmeros acidentes registrados nas LTs em todo o mundo. Neste trabalho, o enfoque é dado à análise dinâmica associada à solicitação proveniente da ruptura de cabos, que quando atuante é capaz de desencadear um fenômeno conhecido como efeito cascata. Para a melhor compreensão da resposta das torres metálicas autoportantes e estaiadas submetidas a esse carregamento dinâmico e buscando contribuir para a determinação de critérios de projeto que visem o estabelecimento adequado de rigidez longitudinal às torres de LTs, foram desenvolvidos modelos numéricos no software ANSYS Mechanical/LS-DYNA, considerando a discretização do modelo estrutural no espaço a partir da utilização do Método de Elementos Finitos e a solução do problema dinâmico ao longo do tempo considerando o método de integração direta implícito das equações de movimento, através do método de Newmark. Inicialmente foram desenvolvidas análises estáticas, conforme considerado nos projetos atualmente. Em seguida, foram desenvolvidos dois tipos de análises dinâmicas: uma simplificada com a aplicação da solicitação através de uma função de carregamento ao longo do tempo, e outra simulada através do desligamento de um elemento finito do condutor. Posteriormente, foram realizadas interpretações e comparações desses resultados. O amortecimento estrutural foi considerado segundo a formulação proposta por Rayleigh e a formação da catenária dos cabos segundo as equações teóricas dadas por Irvine e Caughey. Visando não restringir as respostas a apenas um tipo de trecho simulado, foram desenvolvidos nove modelos numéricos com a variação do tipo de torre analisada, a quantidade de torres por trecho, o nível de amortecimento e o tipo de análise. As respostas dinâmicas são apresentadas em termos da solicitação normal nas barras das estruturas, dos cabos condutores e estais, e dos deslocamentos no topo das torres. / Amidst the main causes of electric energy transmission failure, the collapse of transmission towers is a current research topic in the last decades, due mainly to a huge number of accidents occurring in transmission lines worldwide. In this work, a dynamic analysis was performed associated to the loading due to a broken conductor, which gives rise to a phenomenon known as cascade effect. To better understanding the response of lattice selfsupported and guyed towers under this dynamic load, and in an attempt of determination of criteria for establishment of the longitudinal robustness of transmission line towers, numerical models were developed in the software ANSYS Mechanical/LS-DYNA, considering the discretization of the structural model in space using the finite element method; and the solution of the dynamic problem in the time using the direct integration of the equation of motion, through the Newmark’s method. First, static analyses were performed, accordingly to the considerations of design projects carried out nowadays. Afterwards, two kinds of dynamic analyses were executed: a simplified one, with the applications of the loading using a function in the time and another, which was simulated as a deactivation of a conductor’s finite element. After that, these were submitted to interpretation and comparison among their results. The structural damping was considered in accordance with Rayleigh’s formulation and the catenary of the cables following the equations found by Irvine and Caughey (1974). In order to not restrict the response to one kind of simulation, nine numerical models were developed with the variation of: the kind of tower; the number of towers by line section; the damping level and the type of analysis implemented. The dynamic responses are show in terms of: forces in towers bars; conductors and stays; and the displacements in tower tops.
187

Proteção diferencial digital de linhas de transmissão com compensação série / Digital differential protection of series compensated transmission lines

Eduardo Coelho Navarro 22 August 2002 (has links)
A proteção diferencial é o esquema preferido para proteção de equipamentos e linhas de transmissão. A proteção diferencial exige que informações de todos terminais de zona sob proteção sejam usados para calcular a corrente diferencial. Se esta corrente excede um determinado limite significa que uma falta pode existir na zona protegida. Tais cálculos devem ser executados em cada terminal, consequentemente deve existir um rápido canal de comunicação entre todos os terminais de linha. Este trabalho apresenta o desenvolvimento do algoritmo de uma proteção diferencial digital de linhas de transmissão com compensação em série. O algoritmo proposto foi implementado em Matlab e foi testado com os mais diferentes tipos de faltas simuladas no programa ATP (Alternative Transients Program). Os resultados comprovam o correto funcionamento do algoritmo. O uso de tecnologias atuais de sincronização por GPS (Global Positioning System) e transmissão de dados em banda larga, resolvem antigos problemas da implementação de proteções diferenciais em linhas de transmissão. / The differential protection is the preferred scheme to protect equipment and transmission lines. The differential protection needs information from all terminals of a protected zone to be used to calculate the differential current. If the current exceeds the threshold level, it means that a fault may exist in the protected zone. These computations must be made on each terminal, consequently a fast communication channel connecting all terminals must exist. This work presents the development of a digital differential protection algorithm for series compensated transmission lines. The algorithm was implemented in Matlab and it was tested with the most different variety of faults simulated with ATP (Alternative Transients Program) software. The results proved the correct operation of the algorithm. The use of modern technologies of synchronization such as GPS (Global Positioning System) and data transmission by wide band solved old problems presented by the implementation of differential protection in transmission lines.
188

Detecção e classificação rápida de faltas em linhas de transmissão utilizando redes neurais artificiais / not available

Renan Giovanini 28 August 2000 (has links)
Proteger as linhas de transmissão é uma das tarefas mais importantes dentro dos sistemas elétricos de potência. Faltas em linhas de transmissão devem ser localizadas precisamente e extintas o mais rápido possível. Para tal, o esquema de proteção de linhas utiliza valores amostrados de correntes e tensões para a execução das tarefas de detecção, classificação e localização da falta. Neste esquema, grandezas trifásicas de corrente (IA, IB, IC) e tensão (VA, VB, VC) compõem as entradas do sistema. Após a detecção e classificação da falta, o relé efetua o cálculo da impedância aparente para a verificação da zona de proteção na qual a falta se insere (localização). Dentro deste contexto, a rápida detecção e a correta classificação da falta são passos fundamentais para a lógica de controle de um relé. Para a utilização de sistemas de proteção com alta velocidade de operação, o conjunto detector + classificador deve realizar uma decisão precisa do tipo de falta envolvida em menos de 10 ms após a ocorrência desta. Alguns métodos convencionais têm lidado com este problema, porém os tempos para estimação do tipo de falta são algumas vezes excessivamente longos. Este trabalho apresenta um novo sistema que provê uma rápida e confiável detecção e classificação de faltas através das medidas de valores de correntes trifásicas. O novo método utiliza-se da teoria de Redes Neurais Artificiais, baseada em dois diferentes tipos de redes (MLP e RBF), para a tarefa de detecção e classificação de faltas nos níveis de tempo requeridos para um moderno sistema de proteção. Um estudo comparativo em relação ao desempenho das redes mencionadas também foi realizado. Os testes efetuados para as redes dos tipos MLP e RBF mostraram que o sistema proposto foi capaz de detectar e classificar corretamente 100% dos casos estudados. Deve ainda ser ressaltado, que na maior parte dos casos (93% para a rede MLP e 84% para a rede RBF), o processo de detecção e classificação foi completado com no máximo 5 amostras de pós-falta (5ms). Isto demonstra a rapidez na tarefa de detecção e classificação embutida no método proposto, principalmente levando-se em consideração os tempos apresentados pelos métodos convencionais. / Transmission line protection is one of the major tasks for a power system. Transmission line faults must be located accurately and isolated as fast as possible. In order to perform this task, the power system protection system uses the three-phase currents (IA, IB, IC) and voltages (VA, VB, VC) to detect, classify and locate the fault. After detecting and classifying the fault, the relay calculates the apparent impedance to verify in which protection zone the fault is located. Taking this into account, precise and fast detection and classification methods are fundamental steps for the relay control algorithm. The combination detection + classification must carry out the correct response in less than 10 ms after the fault for a high-speed protection system. Some conventional methods have treated this problem but the time for a correct classification is sometimes excessively long. This work presents a fast and reliable new system for fault detection and classification using the three-phase current measurements. This new system is based on Artificial Neural Networks (RBF and MLP) for the detection and classification tasks. A comparative study involving both types of neural networks was done. Tests showed that the proposed system was able to correctly detect and classify 100% of the studied cases where the majority (93% of the cases for MLP net and 84% for RBF net) of them was done in up to 5 post-fault samples (5 ms). The afore-mentioned demonstrates the high speed of the new method for the detection and classification tasks when compared to the conventional ones.
189

Artificial neural network and Stockwell transform for fault location in transmission lines / Uso de redes neurais artificiais e transformada de Stockwell na localizaÃÃo de faltas em linhas de transmissÃo

Saulo Cunha AraÃjo de Souza 26 June 2015 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / This paper presents an automatic fault location method in transmission lines based on the Travelling Waves Theory (TWT) using the Stockwell Transform (ST) to determine the travelling waves propagation time and the dominant frequency of transient signals generated by faults. The method considers the case where there is no communication between terminals or loss of synchronism between the devices responsible for estimating the location of faults using, therefore, only data from one terminal. Single-phase faults only involving one of the phases and the earth area evaluated, which occur in the first half of a transmission line of unknown parameters. It is observed that the method (i) wasnât sensitive to fault resistance variations and inception angle and (ii) the obtained results presented errors between 0,10% and 5,82% for faults that occurred between 7km and 99km from the monitoring terminal. To improve the accuracy of estimating the fault location, an Artificial Neural Network (ANN) of the type MLP (Multi-Layer Perceptron) is designed, and trained with characteristics extracted from the faulty signals using ST. The ATP (Alternative Transient Program) software was adopted for simulation of a three phase transmission line which voltage signals were sampled at 200kHz. The simulations were performed exploring 1280 combinations of the following parameters: fault locations, fault resistances and inception angle. The method was developed using the software MATLABÂ. According to the obtained results, the combination of ST with ANN presented better results than the application of ST and TWT. Such improvement is highlighted for the estimation of fault location at greater distances from the monitoring terminal, with errors between 0,02% and 1,56% for faults that occurred between 7km and 99km from the monitoring terminal. / Este trabalho apresenta um mÃtodo automÃtico de localizaÃÃo de faltas em linhas de transmissÃo baseado na Teoria das Ondas Viajantes (TOV) utilizando a Transformada de Stockwell (TS) para determinaÃÃo dos tempos de propagaÃÃo das ondas viajantes e da frequÃncia dominante dos sinais transitÃrios gerados pelas situaÃÃes de falta. O mÃtodo considera o caso em que nÃo hà comunicaÃÃo entre terminais ou hà perda de sincronismo entre os equipamentos responsÃveis pela estimaÃÃo da localizaÃÃo das faltas utilizando, portanto, dados provenientes de apenas um terminal. Consideram-se faltas monofÃsicas envolvendo uma das fases e a terra, as quais ocorrem na primeira metade de uma linha de transmissÃo de parÃmetros desconhecidos. Observa-se que o mÃtodo (i) nÃo se mostrou sensÃvel a variaÃÃes de resistÃncia de falta e Ãngulo de incidÃncia e (ii) os resultados obtidos apresentam erros entre 0,10% e 5,82% para faltas que ocorreram entre 7km e 99km do terminal de monitoramento. Para a melhoria da precisÃo na estimaÃÃo da localizaÃÃo das faltas foi projetada uma Rede Neural Artificial (RNA) do tipo MLP (Multi-Layer Perceptron), treinada a partir de caracterÃsticas dos sinais faltosos extraÃdas atravÃs da TS. Foram utilizados os sinais trifÃsicos de tensÃo amostrados na frequÃncia de 200kHz gerados a partir de simulaÃÃes no software ATP (Alternative Transiente Program), no qual foram realizadas 1280 simulaÃÃes explorando diversas localizaÃÃes e resistÃncias de falta e Ãngulo de incidÃncia. O mÃtodo foi aplicado utilizando o software MATLABÂ. De acordo com os resultados obtidos, a combinaÃÃo da TS e RNA projetada apresentou melhores resultados do que a aplicaÃÃo da TS e TOV, destacando-se na estimaÃÃo da localizaÃÃo de faltas que ocorreram a maiores distÃncias do terminal de monitoramento, com erros entre 0,02% e 1,56% para faltas que ocorreram entre 7km e 99km do terminal de monitoramento.
190

Localização de faltas em linhas de transmissão utilizando a teoria de ondas viajantes e transformada Wavelet / Fault Location in Transmission Lines Using Traveling Waves and Wavelet Transform Theory

Murilo da Silva 05 November 2003 (has links)
Este trabalho traz a aplicação da transformada wavelet (TW) para analisar os transitórios de alta freqüência em um sistema de transmissão causados por uma falta sustentada, com o objetivo de se determinar a precisa localização da mesma. A TW, ferramenta matemática empregada neste trabalho, é uma transformação linear muito parecida com a transformada de Fourier, com uma importante diferença: ela permite a localização no tempo de diferentes componentes de freqüência de um dado sinal. Esta localização permite a detecção no tempo da ocorrência de distúrbios abruptos, tais como os transitórios ocasionados por situações de faltas. Os sinais de ondas viajantes geradas pela ocorrência da falta aparecem como distúrbios superpostos aos sinais de freqüência fundamental que são registrados pelos relés. Processando-se estes sinais pelo emprego da TW, esta pode revelar o tempo de propagação dos sinais analisados entre o ponto de ocorrência do distúrbio e a localização física do relé. Conseqüentemente, dispondo-se do intervalo de tempo entre as ondas sobre uma dada linha de transmissão, a distância do ponto de falta pode então ser facilmente determinada, sendo esta a filosofia adotada neste trabalho. O problema delineado é abordado através da implementação prática de um algoritmo computacional. Nesta implementação, o usuário pode escolher a técnica de localização a ser empregada, utilizando-se de dados registrados em um ou em ambos os terminais da linha, conforme a sua necessidade e/ou disponibilidade dos recursos necessários. Com o objetivo de testar e validar a aplicabilidade do algoritmo de localização de faltas, utilizou-se de dados de sinais faltosos obtidos através de simulações do software ATP (Altenative Transients Program), levando-se em conta vários tipos de falta em diferentes localizações ao longo da linha, com diferentes ângulos de incidência, resistências de falta, freqüência de amostragem do sinal, etc. Também foi verificada a influência do acoplamento mútuo em caso de circuitos duplos de transmissão. Os resultados alcançados pelo algoritmo são promissores e demonstram uma ótima precisão e aplicabilidade do método proposto. / This work presents a wavelet transform (WT) application to analyze the high frequency transients in a transmission line caused by a fault, with the purpose of determining its accurate location. The WT is very similar to Fourier Transform (FT), with an important difference: it allows the time determination of different frequency components of a signal. This skill allows the detection of the time of the disturbance occurrence, such as fault transients. The traveling waves generated by the fault occurrence appear as superimposed disturbances on the power frequency signals recorded by the relay. By processing these signals using the WT, the propagation time between the fault point and the relay location can be determined. Consequently, the distance of the fault point can be easily calculated. The delineated problem is boarded through the practical implementation of a computational algorithm. In this implementation, the user can choose the location technique to be employee, using data registered in one or both the terminals of the line, according to the necessity and/or availability of the data. In order to evaluate the applicability of the proposed scheme, the simulation of the transmission line in a faulty condition was utilized. This work makes use of a digital simulator of a faulted EHV (Extra High Voltage) transmission lines known as Alternative Transients Program (ATP). A typical transmission line from CESP (Companhia Energética de São Paulo) were utilized. The simulated data obtained was very close to that found in practice. This study takes into account single phase to ground faults, phase-to-phase faults, phase-phase to ground and three phase faults. The data set was composed of various fault situations considering different fault locations, fault resistances and fault inception angles. The influence of the sampled rate used was also verified as well as the mutual coupling in case of double transmission circuits. The test results reached for the algorithm are promising and demonstrate a highly satisfactory degree of accuracy and applicability of the proposed method.

Page generated in 0.0982 seconds