• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 64
  • 64
  • 32
  • 28
  • 22
  • 22
  • 21
  • 21
  • 18
  • 16
  • 16
  • 16
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Metodologia de localização de defeitos em redes subterrâneas integrando PSCAD/EMTDC e sistemas inteligentes /

Gastaldello, Danilo Sinkiti. January 2012 (has links)
Orientador: André Nunes de Souza / Banca: Helio Eiji Sueta / Banca: Pedro da Costa Junior / Resumo: Com a modernização da sociedade e o grande crescimento tecnológico visto nos últimos anos, é difícil de imaginar a ausência da energia elétrica nos dias atuais, pois tudo depende da energia para funcionar. A energia elétrica é fundamental para todos os setores da sociedade: residencial, comercial e industrial. A qualidade de seu fornecimento também é muito importante, pois é a qualidade que garante o correto funcionamento de todos os processos realizados no dia-a-dia. No entanto, nenhum sistema, por melhor que seja, é imune à ocorrências de falhas. Assim sendo, uma boa monitoração destas falhas é necessária para realização de manobras de correção mais eficientes. Além disso, a crescente preocupação ambiental faz com que as concessionárias busquem melhores formas de levar a energia à energia à população, com redes mais seguras, mais confiáveis e também mais baratas. Os sistemas subterrâneos têm demonstrado ser uma boa solução no que diz respeito à segurança, confiabilidade e preocupação ambiental, porém a sua instalação ainda é muito cara em comparação com as redes aéreas convencionais. Como todos os sistemas, as redes subterrâneas também estão sujeitas a defeitos. A correta localização a falta (defeito) em cabos subterrâneos de distribuição de energia elétrica não é uma tarefa trivial. Além da dificuldade de acesso ao sistema, existe o alto custo das medições dos parâmetros e a necessidade de uma análise de um especialista dos sinais medidos, ocasionando erros que têm se mostrado custosos. A proposta desta dissertação consiste em estudar os sistemas subterrâneos através de ferramentas computacionais e desenvolver um sistema inteligente que auxilie com a precisão de localização de faltas subterrâneos de distribuição de energia elétrica / Abstract: With the modernization of society and the great technological growth in the last years, it is hard to imagine the absence of electric power nowadays, because everything depends on energy to work. Electricity is fundamental to all sectors of society: residential, commercial and industrial. The quality supply is also very important, since quality guarantees the correct functioning of all processes performed in a daily basis. However, no system is immune to the occurrence of faults. Therefore, a good monitoring of these faults is necessary for more efficient correction adjustments. In addition, the growing environmental concerns make the power utilities to find better ways to take energy to the population, through safer more reliable and also cheaper networks. The underground system has be found to be a good approach to improve safety, reliability and environmental features, but its installation is still very expensive when compared to conventional overhead systems. Like any system, the underground networks are subjects to defects. The correct fault localization (defect) in eletricity distribution underground networks is not a trivial task, it is not just due to a difficult system acess, the high cost of measurements of the parameters and the required expert analysis of the measured signals. These factors are source of errors that have proven costly. The purpose of this dissertation is to study underground system using computational tools and develop an intelligent system to accurately assist to locating of faults in underground cables of power distribution networks / Mestre
32

Estudo experimental de transitórios eletromagnéticos em sistemas de aterramento elétrico devidos a pulsos de descargas atmosféricas

CARVALHO, Lorena de Fátima Pinheiro de 29 May 2015 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-26T12:54:55Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoExperimentalTransitorios.pdf: 13678161 bytes, checksum: 780cae26691a9124afb06d9d60cf88e2 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-26T13:16:25Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoExperimentalTransitorios.pdf: 13678161 bytes, checksum: 780cae26691a9124afb06d9d60cf88e2 (MD5) / Made available in DSpace on 2017-01-26T13:16:25Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoExperimentalTransitorios.pdf: 13678161 bytes, checksum: 780cae26691a9124afb06d9d60cf88e2 (MD5) Previous issue date: 2015-05-29 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho, é apresentado um estudo sobre o comportamento transitório e de regime estacionário de sistemas de aterramento quando submetidos a surtos com forma de onda de uma descarga atmosférica. As análises dos sistemas de aterramento foram feitas por meio de dados obtidos através de experimentos realizados em campo e de simulações numéricas baseadas no método das diferenças finitas aplicado para solucionar as equações de Maxwell no domínio do tempo. Nas simulações numéricas, o setup experimental (hastes, cabos, resistor e sinal injetado) e os parâmetros eletromagnéticos do solo e Vácuo (condutividade, permissividade elétrica e permeabilidade magnética) foram modelados numericamente. Observou-se boa concordância entre os sinais medidos durante os testes experimentais e os seus respectivos sinais obtidos numericamente. Esta concordância entre os sinais transitórios medidos e simulados foi obtida tomando-se determinados cuidados técnicos ao se conceber o setup experimental. Tais cuidados técnicos, que normalmente não são postos de forma explícita na literatura, são devidamente abordados e discutidos nesta dissertação. / In this dissertation, we present a study on the transient and steady-state behaviors of grounding systems when subjected to surges with the waveform of a lightning discharge. The analyses of grounding systems were made using data obtained through experiments conducted in the field and numerical simulations based on the finite-difference method applied to solve Maxwell’s equations in the time domain. In numerical simulations, the experimental setup (rods, cables, resistor and injected signal) and the electromagnetic parameters (conductivity, permittivity and magnetic permeability) of soil and vacuum were modeled numerically. There was good agreement between the measured signals during the experimental tests and their respective signals obtained numerically. This agreement between measured and simulated transient signals was obtained by taking certain technical precautions when designing the experimental setup. Such technical precautions, which are usually not explicitly mentioned in technical literature, are properly addressed and discussed in this dissertation.
33

Desenvolvimento e implementação de gerador de surto e sua aplicação na análise numérico-experimental do comportamento transitório de sistemas de aterramento.

ARAÚJO, Ramon Cristian Fernandes 21 September 2015 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-02-10T18:57:29Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolvimentoImplementacaoGerador.pdf: 7993868 bytes, checksum: 33fa33f123f54fd3e73540b41d5b35e3 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-02-14T15:02:21Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolvimentoImplementacaoGerador.pdf: 7993868 bytes, checksum: 33fa33f123f54fd3e73540b41d5b35e3 (MD5) / Made available in DSpace on 2017-02-14T15:02:21Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolvimentoImplementacaoGerador.pdf: 7993868 bytes, checksum: 33fa33f123f54fd3e73540b41d5b35e3 (MD5) Previous issue date: 2015-09-21 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho, são apresentadas em detalhes, as etapas do projeto e construção de um gerador de surto de tensão com base em normas internacionalmente estabelecidas (IEC 61000-4-5). Os dois sinais de saída implementados possuem formas de onda características de surtos devidos às descargas atmosféricas primeira e subsequente, respectivamente. Ainda, seus parâmetros obedecem aos valores padronizados pelas normas IEC 60060-1 e IEEE Std-4. A fim de validar o gerador de surto construído, foram analisados os comportamentos transitório e estacionário de diversos sistemas de aterramento quando submetidos a descargas atmosféricas, utilizando o referido gerador como fonte do sinal de injeção. Os sistemas de aterramento foram analisados mediante experimentos em campo, sendo que cada experimento foi reproduzido numericamente através do método FDTD. Baixos erros percentuais foram obtidos entre os sinais medidos durante os experimentos e os sinais numéricos correspondentes. Isso, aliado ao fato de que os aterramentos analisados se comportaram conforme o esperado na literatura, valida o gerador de surto construído neste trabalho. / In this work, the design and construction steps of a voltage surge generator are detailed based on established international standards (IEC 61000-4-5). The waveforms of the two output signals implemented are representative of surges due to the first and subsequent lightning strokes, respectively. Also, their parameters meet the requirements imposed by the standards IEC 60060-1 and IEEE Std-4. In order to validate the surge generator, it was analyzed the transient and steady-state behaviors of several grounding systems when subjected to lightning strokes, using the developed generator as the source of the injection signal. The grounding systems were analyzed by field experiments, and each experiment was reproduced numerically using the FDTD method. Low percentage errors were obtained between the signals measured during the field experiments and the corresponding numerical signals. Moreover, the analyzed grounding systems behaved as expected in literature. Those two facts validade the surge generator built in this work.
34

Um método para modelagem numérica plena da dispersão elétrica do solo usando aproximadores de padé e o método das diferenças finitas no domínio do tempo

NASCIMENTO, Júlio Antônio Salheb do 29 February 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-03-28T11:55:28Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_MetodoModelagemNumerica.pdf: 7926563 bytes, checksum: c9cc3b2a11cac810ac516048be14a69c (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-28T13:19:26Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_MetodoModelagemNumerica.pdf: 7926563 bytes, checksum: c9cc3b2a11cac810ac516048be14a69c (MD5) / Made available in DSpace on 2017-03-28T13:19:26Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_MetodoModelagemNumerica.pdf: 7926563 bytes, checksum: c9cc3b2a11cac810ac516048be14a69c (MD5) Previous issue date: 2016-02-29 / Nesta Dissertação, é desenvolvido e implementado em software um método para modelagem da dispersão elétrica do solo através do método das diferenças nitas no domínio do tempo (FDTD). A metodologia é baseada na aplicação de aproximadores de Padé no domínio da frequência, de forma a representar a dependência espectral tanto da condutividade quanto da permissividade elétrica. As equações no domínio do tempo são obtidas através de simples manipulações algébricas e transformadas inversas de Fourier. Resultados obtidos experimentalmente em sistemas de aterramento solicitados por descargas atmosféricas articialmente produzidas são comparados aos resultados numéricos obtidos através do método proposto. Excelente concordância entre os sinais transitórios é observada. / In this dissertation, it is developed and implemented a numerical method for modeling the soil electrical dispersion using the Finite-Dierence Time-Domain method (FDTD). The methodology is based on the application of Padé approximants in frequency domain, in such a way to represent the spectral dependency of soil's conductivity and electrical permittivity. The time domain equations are obtained using simple algebraic operations and inverse Fourier transforms. Experimental results for grounding systems subjected to articial lightning pulses are compared with numerical results obtained using the proposed method. It was observed an excellent agreement between the corresponding transient signals.
35

Metodologia de localização de defeitos em redes subterrâneas integrando PSCAD/EMTDC e sistemas inteligentes

Gastaldello, Danilo Sinkiti [UNESP] 03 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-03Bitstream added on 2014-06-13T19:08:09Z : No. of bitstreams: 1 gastaldello_ds_me_bauru.pdf: 1214010 bytes, checksum: 29dee0e501a74b98535a82f676d332d4 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Com a modernização da sociedade e o grande crescimento tecnológico visto nos últimos anos, é difícil de imaginar a ausência da energia elétrica nos dias atuais, pois tudo depende da energia para funcionar. A energia elétrica é fundamental para todos os setores da sociedade: residencial, comercial e industrial. A qualidade de seu fornecimento também é muito importante, pois é a qualidade que garante o correto funcionamento de todos os processos realizados no dia-a-dia. No entanto, nenhum sistema, por melhor que seja, é imune à ocorrências de falhas. Assim sendo, uma boa monitoração destas falhas é necessária para realização de manobras de correção mais eficientes. Além disso, a crescente preocupação ambiental faz com que as concessionárias busquem melhores formas de levar a energia à energia à população, com redes mais seguras, mais confiáveis e também mais baratas. Os sistemas subterrâneos têm demonstrado ser uma boa solução no que diz respeito à segurança, confiabilidade e preocupação ambiental, porém a sua instalação ainda é muito cara em comparação com as redes aéreas convencionais. Como todos os sistemas, as redes subterrâneas também estão sujeitas a defeitos. A correta localização a falta (defeito) em cabos subterrâneos de distribuição de energia elétrica não é uma tarefa trivial. Além da dificuldade de acesso ao sistema, existe o alto custo das medições dos parâmetros e a necessidade de uma análise de um especialista dos sinais medidos, ocasionando erros que têm se mostrado custosos. A proposta desta dissertação consiste em estudar os sistemas subterrâneos através de ferramentas computacionais e desenvolver um sistema inteligente que auxilie com a precisão de localização de faltas subterrâneos de distribuição de energia elétrica / With the modernization of society and the great technological growth in the last years, it is hard to imagine the absence of electric power nowadays, because everything depends on energy to work. Electricity is fundamental to all sectors of society: residential, commercial and industrial. The quality supply is also very important, since quality guarantees the correct functioning of all processes performed in a daily basis. However, no system is immune to the occurrence of faults. Therefore, a good monitoring of these faults is necessary for more efficient correction adjustments. In addition, the growing environmental concerns make the power utilities to find better ways to take energy to the population, through safer more reliable and also cheaper networks. The underground system has be found to be a good approach to improve safety, reliability and environmental features, but its installation is still very expensive when compared to conventional overhead systems. Like any system, the underground networks are subjects to defects. The correct fault localization (defect) in eletricity distribution underground networks is not a trivial task, it is not just due to a difficult system acess, the high cost of measurements of the parameters and the required expert analysis of the measured signals. These factors are source of errors that have proven costly. The purpose of this dissertation is to study underground system using computational tools and develop an intelligent system to accurately assist to locating of faults in underground cables of power distribution networks
36

Análise de desempenho do protocolo DNP3 encapsulado sobre PLC para aplicações em Redes Inteligente

Silva, Marcos Antônio Andrade 28 August 2017 (has links)
The use of smart grids is a reality in several developed countries, being a natural evolution for the electrical grids of any developing country, like Brazil. This evolution takes place through the interaction of communication systems with the electrical grids in a bidirectional communication of both data and energy flow using different protocols and communication technologies. Its validation occurs by the physical installation of equipments, or alternatively by computational simulators. This paper demonstrates through simulation the use viability of DNP3 (Distributed Network Protocol) encapsulated over TCP/IP over PLC (Power Line Communication). The network simulator software NS-2 was employed for PLC channel modeling and DNP3 implementation. Some quality parameters, such as packet loss, latency and thoughput, were evaluated under several scenarios. / A utilização de redes inteligentes de energia é uma realidade em diversos países desenvolvidos, sendo uma evolução natural para a rede elétrica de qualquer país em vias de desenvolvimento, como é o caso do Brasil. Essa evolução dá-se por uma interação dos sistemas de comunicação com as redes elétricas, em uma comunicação bidirecional, tanto de dados como de fluxo de energia, utilizando para isso protocolos e tecnologias de comunicação diferentes, cuja validação ocorre com uma instalação física dos equipamentos associados, ou, como alternativa, por simulação computacional. Este trabalho demonstra através de simulações a viabilidade do uso do protocolo DNP3 (do inglês Distributed Network Protocol) encapsulado em TCP/IP e em PLC (do inglês Power Line Communication) para aplicações em redes inteligentes, exceto para atividades que necessitem de comunicação em tempo real. Foram empregados o software de simulação de redes NS-2 para modelagem do canal PLC e do protocolo DNP3 e verificados parâmetros de qualidade, como perda de pacotes, latência e vazão de dados sob diversos cenários de aplicações. / São Cristóvão, SE
37

Calculo dos parametros de linhas de transmissão trifasicas atraves das tensões e correntes em seus terminais / Calculation of parameters of thress-phase transmission lines through voltages and currents in their terminals

Lustosa, Leonardo Silva 14 August 2018 (has links)
Orientadores: Jose Pissolato Filho, Sergio Kurokawa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-14T06:30:33Z (GMT). No. of bitstreams: 1 Lustosa_LeonardoSilva_M.pdf: 1611174 bytes, checksum: 2c164206f95ffdeb84cf75eeff5c9f1b (MD5) Previous issue date: 2009 / Resumo: O objetivo deste trabalho é calcular os parâmetros longitudinais e transversais de linhas de transmissão trifásica a partir das correntes e tensões nas fases das mesmas. Serão utilizadas equações desenvolvidas no domínio modal considerando as obtenções de correntes e tensões em um terminal da linha enquanto o outro terminal permanece em aberto ou em curto-circuito. Inicialmente é apresentada a teoria básica de linhas de transmissão partindo do pressuposto de que tais linhas são melhores representadas através do modelo de parâmetros distribuídos. Assim através da análise de circuitos elétricos e das leis de Kirchhoff são encontradas as equações diferenciais de segunda ordem de tensão e corrente que caracterizam a linha de transmissão. Em seguida é apresentada a metodologia para cálculo dos parâmetros da linha que utiliza a idéia de impedância equivalente de circuito aberto e curto-circuito quando um dos terminais está em aberto e em curto-circuito respectivamente. Utilizando o Toolbox SimPowerSystem do MatLab são simuladas a obtenção das correntes em linhas de transmissão trifásica de 330 kV, 440 kV e 500 kV, todas com comprimento igual a 500 km. De posse de tais correntes são calculados os parâmetros das linhas de transmissão e comparados com seus valores reais, mostrando a viabilidade da metodologia empregada e que o erro obtido com tal metodologia é menor do que o erro entre os parâmetros reais das linhas após construção e seus parâmetros de projeto existente nos bancos de dados das empresas. / Abstract: The objective of this work is to calculate the longitudinal and transversal transmission line parameters using phase currents and voltages. Developed equations are used, in the modal domain, considering current and voltages found between a line terminal and an open line terminal, and a short-circuit terminal. . Initially, the basic transmission line theory is presented assuming that these lines are best represented by distributed parameters model. Therefore, through the analysis of electric circuits and Kirchhoff's laws , second order differential equations for voltage and current are found, which characterizes the line transmission. Next it is shown the method to calculate the line parameters, which uses the concept of open circuit and short-circuit equivalent impedance when one of the terminals is open or in short-circuited respectively. Using the Toolbox of MatLab, SimPowerSystem, estimated currents are simulated in a three-phase transmission line of 330 kV, 440 kV and 500 kV, all with the length of 500 km. The found values are used to calculate parameters of lines transmission and to compared them with their real values, showing that the calculation is possible and that the error obtained with this method is smaller than an error between the real line parameters after construction and those of existing project in the data base of companies. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
38

Analise de sensibilidade de parametros eletricos de linhas de transmissão no dominio da frequencia / Sensitivity analysis of electrical transmission line parameters in frequency domain

Pinheiro, Michel Gonçalves 17 November 2005 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e Computação / Made available in DSpace on 2018-08-08T12:51:45Z (GMT). No. of bitstreams: 1 Pinheiro_MichelGonA§alves_M.pdf: 1094075 bytes, checksum: 1c9863b695ee82d8312c89c87f94085b (MD5) Previous issue date: 2005 / Resumo: Este trabalho apresenta uma extensa análise de sensibilidade dos parâmetros elétricos longitudinais e transversais de uma linha de transmissão trifásica em função da freqüência. Uma linha real de 440 kV foi utilizada como base para as análises. Considerando determinadas hipóteses simplificadoras, foram calculados os parâmetros elétricos da linha: resistência, indutância e capacitância no domínio da freqüência. Esses parâmetros foram apresentados em termos das parcelas das matrizes primitivas, das matrizes reduzidas e componentes modais. Na análise de sensibilidade variaram-se as seguintes características da linha: diâmetros dos cabos pára-raios, diâmetros dos condutores fase, altura dos condutores, distância horizontal entre as fases, espaçamento vertical dos sub-condutores dos feixes das fases externas. Para cada variação observou-se o comportamento dos parâmetros elétricos em função da freqüência, em termos das parcelas das matrizes primitivas e em termos dos modos. Também foi observado o fator de aterramento e foram estimados os aumentos de potência natural em função das variações realizadas. As linhas com elevada potência natural (LPNE) foram avaliadas no âmbito da análise efetivada / Abstract: In this work a large sensitivity analysis of longitudinal and transversal electrical parameters of a three-phase transmission line in frequency domain was performed. An actual 440 kV transmission line was used as reference in the analysis. Considering some simplified hypothesis, electrical parameters, as resistance, inductance and capacitance, were evaluated in frequency domain. Those parameters were presented in terms of parcels of primitive matrices and reduced matrices in phase modal domain. An extensive sensitivity analysis was performed and the following line caracteristics were varied: ground wires diameter, phase conductors diameter, height of conductors, horizontal distance among phases and vertical spacing within external phases bending. For each line caracteristic, the performance of electrical parameters in frequency domain, in terms of primitive and modal matrices was observed. Also, it was observed the ground factor and it was estimated the increases on natural power. Using of High Natural Power Lines was studied and related to variations of line geometry / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
39

Obtenção dos parâmetros sustentados para modelagem de arco secundário em linha de 500 kV / Stationary parameters for secondary arc modeling in a 500 kV transmission line

Garcia, Athos Póvoa, 1988- 07 March 2014 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-26T08:28:58Z (GMT). No. of bitstreams: 1 Garcia_AthosPovoa_M.pdf: 9594597 bytes, checksum: c99eaf2e0c3c48d6e04df60e99d62937 (MD5) Previous issue date: 2014 / Resumo: Este trabalho apresenta uma metodologia para a obtenção dos parâmetros sustentados do arco elétrico, especificamente a corrente de condução e a corrente de deslocamento. Os resultados apresentados são provenientes da análise de 410 ensaios realizados em ambiente não confinado de um trecho experimental de linha de transmissão aérea de 500 kV , composta por três torres e dois vãos. Foram analisados diversos níveis de corrente entre 15 Aef e 10 kAef. O método apresentado é baseado na obtenção de um novo elemento para a caracterização do arco elétrico, a capacitância. Verifica-se que existe um atraso da forma de onda da tensão entre os terminais do arco em relação à forma de onda da corrente do arco elétrico próximo ao cruzamento das curvas pelo zero. Este comportamento indica uma resposta a um circuito que não pode ser considerado puramente resistivo, mas sim composto por uma resistência e uma capacitância. Desta forma a contribuição da presente pesquisa consiste na identificação da capacitância do arco elétrico. Os resultados obtidos mostram que a utilização da metodologia desenvolvida é eficaz para a obtenção dos parâmetros sustentados do arco elétrico e que tais parâmetros possuem uma relação de proporcionalidade em relação aos níveis de corrente do arco elétrico / Abstract: This work presents a methodology to obtain the stationary parameters of the electric arc, specifically the conductive current and the displacement current. The results presented are from analysis by 410 assays performed at field tests of a test section of 500 kV transmission line. The section is formed by three transmission towers, one anchor tower positioned between two suspension towers. This work presents the analysis of tests with current levels between 15 Arms and 10 kArms. The presented method is based on obtaining a new element to characterize the arc, the capacitance. It is verified that there is a delay of the waveform of the voltage across the arc terminals relative to the waveform of the current arc near zero crossing. This behavior indicates that the arc can not be considered purely resistive, but instead it has a behavior of a parallel resistance and a capacitance impedance. Therefore the contribution of this research is to identify the capacitance of the electric arc. The results show that the use of the developed methodology is effective for obtaining the stationary parameters of the electric arc and that these parameters have a relationship of proportionality in relation to the arc current range.winz / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
40

Controle adaptativo para religamento tripolar aplicado a linhas de transmissão com compensação reativa em derivação / Adaptive control for three phase reclosing applied to shunt reactor compensated transmission lines

Mestas Valero, Patricia 19 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T10:56:05Z (GMT). No. of bitstreams: 1 MestasValero_Patricia_D.pdf: 4018272 bytes, checksum: 38a65b52b68046f67c3791c9b6ea2f7d (MD5) Previous issue date: 2011 / Resumo: O presente trabalho descreve um novo método de controle adaptativo para chaveamento sincronizado de disjuntores durante a manobra de religamento tripolar de linhas de transmissão com compensação reativa em derivação. O objetivo principal do método desenvolvido é controlar as sobretensões transitórias e reduzir o tempo morto antes do religamento. Diferentes estratégias para controlar sobretensões decorrentes do religamento tripolar são descritas com a finalidade de diferenciar as vantagens do chaveamento sincronizado. Os benefícios potenciais a serem obtidos a partir do religamento tripolar rápido são expostos. O método de controle adaptativo desenvolvido consiste em identificar com antecedência a região ótima para o religamento, permitindo fechar o disjuntor já no primeiro mínimo do batimento da tensão entre os contatos do disjuntor após o tempo morto de atuação da proteção. Após os testes realizados utilizando um programa para simulação de transitórios eletromagnéticos (PSCAD/EMTDC), o método proposto foi implementado em protótipo (controlador). Este protótipo foi testado utilizando o Simulador Digital em Tempo Real (RTDS). As simulações em tempo real demonstraram a eficiência do método no controle das sobretensões e na redução do tempo morto. Finalmente, o método foi avaliado parametricamente para uma série de condições simuladas, incluindo diferentes níveis de compensação reativa em derivação, a influência da compensação série, a influência da transposição da linha de transmissão e os efeitos da variação do comprimento da linha. Além disto, outras simulações foram realizadas para comparar o desempenho dos métodos de controle existentes e do método proposto / Abstract: The present thesis describes a new adaptive control method for synchronous switching of circuit breakers during three-phase reclosing of shunt compensated transmission lines. The main objective of the developed method is to control the overvoltages and to reduce the dead time prior of reclosing. Several strategies to control overvoltages resulting from three-phase reclosing are described in order to differentiate the benefits of the proposed method. The potential benefits obtained from the developed controlled reclosing method are exposed. The proposed algorithm identified, in advance, the optimal region for reclosing of transmission line, allowing closing the circuit breaker at the first minimum voltage beat across circuit breaker, after protection dead time. After off-line testing using electromagnetic transients simulation program (PSCAD/EMTDC), the proposed method was also implemented in physical hardware. This hardware was then tested on a real-time transients simulator (RTDS). The real time simulations demonstrate the method efficiency to control overvoltages and to reduce the dead time. Finally, the method has been parametrically evaluated for a range of simulated conditions, including different shunt compensation levels, influence of series compensation, influence of transmission line transposition, effect of line lengths. In addition, simulations have been conducted to compare the performance of existing control method and the proposed method / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica

Page generated in 0.074 seconds