51

Proposta de novas técnicas de modelagem para estudo da redução do potencial de passo e aterramento por elementos de circuito

ARAÚJO, Humberto Xavier de 01 August 2007 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-03-27T13:59:16Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_PropostasNovasTecnicas.pdf: 9171936 bytes, checksum: cf7338076498c1c851a05340e572cc7a (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-28T12:59:56Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_PropostasNovasTecnicas.pdf: 9171936 bytes, checksum: cf7338076498c1c851a05340e572cc7a (MD5) / Made available in DSpace on 2017-03-28T12:59:56Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_PropostasNovasTecnicas.pdf: 9171936 bytes, checksum: cf7338076498c1c851a05340e572cc7a (MD5) Previous issue date: 2007-08-01 / Neste trabalho são apresentadas novas técnicas para promoção da redução do potencial de passo em sistemas de aterramento, bem como analises à respeito das já existentes na literatura. Para alcançar tal objetivo, lançou-se mão de recursos como curvar as bordas das malhas de terra (modelo guardachuva) e uso de ramificações em hastes de aterramento (modelo fractal). Os resultados obtidos mostram claramente que as tais propostas são bastante promissoras e eficientes, principalmente por se tratar de um problema de grande importância para a segurança das pessoas e dos equipamentos. Reduções no potencial de passo de até 85% foram obtidas. É proposto também, a utilização de elementos de circuito concentrados com o objetivo de se criar um modelo de aterramento capaz de operar nos mais diversos tipos de solo. Para a análise das estruturas consideradas, é utilizado um software no qual as equações de Maxwell são resolvidas numericamente através do método das Diferenças Finitas no Domínio do Tempo (método FDTD) associado à truncagem do domínio de análise pela técnica UPML e à representação dos condutores elétricos por uma formulação de fio fino para meios condutivos. / This work presents new techniques to reduce the step potential in grounding systems, as well as analysis regarding others present in the literature. For this goal, some resources were employed, such as to bent the mesh grounding borders (Umbrella Model) and the use of ramifications on the grounding rods (Fractal Model). The obtained results clearly show that the proposals are promising and efficient, mainly when dealing with a problem of large importance for people and equipment security. Reductions up to 85% in the step potential were obtained. It is also proposed here, the employment of lumped parameteres circuit elements, aiming at a ground system model capable to operate in any kind of the existing grounds. In order to analyze the structures, a software was utilized in which Maxwell’s equations are numerically solved by the FDTD Method associated to the UPML technique, and thin wires in a lossy medium.
52

Analise de sensibilidade da corrente de arco secundario para diferentes linhas de transmissão / Sensitivity analysis of secondary arc current for different transmission lines

Zevallos Alcahuaman, Milton Elvis, 1974- 13 August 2007 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-10T09:15:34Z (GMT). No. of bitstreams: 1 ZevallosAlcahuaman_MiltonElvis_M.pdf: 2029693 bytes, checksum: 59155e98cbc8a1da85069d7cec8f451e (MD5) Previous issue date: 2007 / Resumo: O arco secundário surge na manobra de abertura monofásica durante a eliminação de faltas monofásicas não permanentes para terra. O problema se apresenta especialmente nas linhas de EAT, no isolamento aéreo, em faltas que têm características não permanentes. Neste trabalho analisamos diferentes linhas de transmissão com níveis de tensão de 345 kV até 765 kV e com comprimentos de 150 km até 900 km, variando seu nível de compensação reativa em derivação de 40 % até 100 % e para as linhas mais longas compensando também 50 % da sua impedância longitudinal. Em linhas de EAT com compensação reativa em derivação é possível aproveitar a associação dos reatores adicionando um reator de neutro para minimizar o acoplamento mútuo entre as fases das linhas de transmissão, sendo este acoplamento a causa principal da manutenção da corrente de arco secundário. Com valores de reatores de neutro ótimos minimizamos a corrente de arco secundário e avaliamos a viabilidade da aplicação do religamento monofásico nos sistemas em estudo, aumentando o desempenho e confiabilidade dos sistemas elétricos / Abstract: The secondary arc appears in single-phase switching during clearing of non-permanent ground single-phase to ground faults. The problem happens especially on EHV lines, on aerial isolation, in faults with non permanent characteristics. In this work different transmission lines with voltage levels of 345 kV up to 765 kV and with 150 km up to 900 km length are analyzed, varying its level of reactive shunt compensation from 40 % up to 100 % and for the longest lines compensating 50 % of its longitudinal impedance. In EHV lines with have reactive shunt compensation, it is possible to add a neutral reactor in order to minimize the phase coupling of the transmission lines, being this coupling the main cause for the maintenance of the secondary arc current. With optimal values of neutral reactors it was possible to minimize the secondary arc current and evaluate the viability of the application of the single-phase reclosure in the systems under study, increasing the performance and reliability of the electrical systems / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
53

Influência da condutividade e permissividade do solo em função da frequência no cálculo da impedância longitudinal e admitância transversal de linhas aéreas de transmissão / Influence of earth's conductivity and permittivity frequency dependence on longitudinal impedance and transversal admittance transmission line's parameters calculation

Gertrudes, João Bosco 16 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-16T03:57:35Z (GMT). No. of bitstreams: 1 Gertrudes_JoaoBosco_D.pdf: 5500576 bytes, checksum: ef85206048f845d1bff89f7c8948d288 (MD5) Previous issue date: 2010 / Resumo: Esta tese tem como objetivo o desenvolvimento de modelos mais precisos para o cálculo de parâmetros elétricos de linhas aéreas de transmissão para estudos de transitórios na faixa de frequência 0 a 2 MHz. Esta faixa de frequência cobre a maioria das perturbações eletromagnéticas nos sistemas elétricos: energização, faltas simétricas e assimétricas, rejeições de carga, descargas atmosféricas, perturbações harmônicas, etc. Na faixa de frequência citada, em consequência da dependência dos parâmetros do solo com a frequência, a condutividade elétrica do solo (sg) tem a mesma ordem de grandeza que o produto entre a frequência angular do sinal incidente no solo (w) e a permissividade elétrica do solo (eg). Portanto, as suposições de baixa frequência tradicionalmente adotadas - sg constante e weg desprezível (sg >> weg) - podem levar a modelos que não representam de forma adequada a resposta da linha no caso de transitórios rápidos (com espectro de frequência acima de 1 kHz). O objetivo central desta tese é verificar a influência da dependência dos parâmetros do solo no cálculo da impedância longitudinal e admitância transversal por unidade de comprimento em comparação com os modelos tradicionais de cálculo. As análises são feitas inicialmente para o caso de um único condutor acima do solo e posteriormente através de um estudo para uma linha de transmissão trifásica, 440 kV, em operação no sistema elétrico brasileiro. As impedâncias longitudinais e as admitâncias transversais de retorno pelo solo são avaliadas através de métodos tradicionais de cálculo e através de integração numérica das formulações de Carson modificadas para inclusão do modelo de solo que considera a depêndencia de sg e weg em função da frequência / Abstract: This thesis aims to propose more accurate models for calculating the electrical parameters of overhead power transmission lines. The influence of earth's conductivity and permittivity frequency dependence is evaluated when calculating transversal and longitudinal transmission lines' parameters in the frequency range 0 to 2 MHz. This frequency range covers the majority of the electromagnetic transients in electrical systems (switching transients, faults' transients, load rejections, harmonic disturbances, etc). Between 1 kHz to 2 MHz, the product of the signal angular frequency (w) by the dielectric constant (eg) of the soil may have the same order of magnitude as the conductivity (sg), due to the variation of these parameters with frequency. Therefore, the assumptions of low frequency traditionally used - the soil conductivity (sg) considered as constant and weg that can be negligible (sg >> weg) - can lead to incorrect models that do not adequately represent the transmission line's response, in cases of fast transients phenomena (with frequency spectrum above 1 kHz). The importance of properly considering the frequency dependent soil model is presented for the one-conductor case and for a single three-phase transmission line (440 kV, considered ideally transposed). The aim is to compare the transmission line parameters calculated considering the conductivity and weg frequency dependence ground model in relation to the common ground representation, with constant conductivity and weg that may be neglected. It is also compared the results obtained from the complex plane method with those obtained from the Carson's modified expressions for longitudinal parameters and between Carson's modified potential-coefficient correction factors and from the most common approximated methods for transversal admittance parameters / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
54

Uma contribuição ao estudo do efeito corona em linhas de transmissão / A contribution to the study of the corona effect in transmission lines

Freitas, Michelly Alcantara de 15 June 2007 (has links)
Orientadores: Jose Pissolato Filho, Sergio Kurokawa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-09T06:33:17Z (GMT). No. of bitstreams: 1 Freitas_MichellyAlcantarade_M.pdf: 1141604 bytes, checksum: a3e880984ac7598f64499a8ad34269b7 (MD5) Previous issue date: 2007 / Resumo: Neste trabalho é mostrado um estudo a respeito do efeito corona em linhas de transmissão. A linha de transmissão foi representada por meio de uma cascata de circuitos 1t e o efeito da freqüência sobre os parâmetros longitudinais da linha foi representado por meio de uma associação série e paralela de resistores e indutores. Neste trabalho o efeito corona foi representado por meio dos modelos de Gary e de Skilling-Umoto devido ao fato destes modelos permitirem a sua inserção na cascata de circuitos 1t. O sistema mencionado anteriormente foi utilizado para representar a linha por meio de variáveis de estado, onde as equações de estado são a corrente longitudinal e a tensão transversal em cada um dos circuitos 1t. O modelo desenvolvido foi utilizado para simular as sobretensões originadas por uma descarga atmosférica em uma linha monofásica. Os resultados obtidos foram comparados com resultados experimentais mostrados em outros trabalhos. Esta comparação mostrou que os resultados obtidos com o modelo proposto são bem próximos aos resultados obtidos experimentalmente. / Abstract: In this work it is presented a study about the corona effect in transmission lines. The line was represented as being a cascade of 1t circuits and the frequency dependence of the longitudinal parameters of the line was synthesized with series and parallel resistors and inductors. In this work was used the Gary's model and Skilling-Umoto model for representing the corona effect because they can be inserted in the cascade. of 1t circuits. With the system above mentioned, a state model of the line was obtained using longitudinal currents and transversal voltages in each 11 circuit as the state variables. The proposed model was used to simulate the over voltages resulting of a lighting surge in a single-phase line. The simulation results were compared with experimental results that are available in several papers. It is possible to conclude that results obtained with proposed model are in agreement with experimental results. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
55

Alterações topológicas para reduzir a propagação de falhas na rede elétrica de alta tensão brasileira / Topological changes to prevent failure propagation on the Brazilian power transmission lines

Paiva, William Roberto de, 1986- 24 August 2018 (has links)
Orientadores: André Franceshi de Angelis, José Geraldo Pena de Andrade / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Tecnologia / Made available in DSpace on 2018-08-24T15:13:51Z (GMT). No. of bitstreams: 1 Paiva_WilliamRobertode_M.pdf: 3222455 bytes, checksum: 4ba3e5407135ec1d8483e94ec4c11749 (MD5) Previous issue date: 2014 / Resumo: Neste trabalho, propõe-se a avaliação de quatro métodos que possam melhorar a resiliência de redes de alta tensão através da adição de linhas de transmissão, utilizando-se a Teoria das Redes Complexas. Criou-se um modelo da rede brasileira de geração e transmissão de energia elétrica em forma de grafo para testar os métodos. O primeiro deles consiste em ligar pares de vértices que possuam menor grau em toda a rede. O segundo liga os vértices de menor betweenness. O terceiro efetua ligações entre pares de vértices de menor grau que estejam ligados aos vértices de maior carga em toda a rede. O último, faz ligações entre os dois vértices de betweenness mediano. Todos os métodos foram testados com e sem o auxílio do procedimento "min-cut", capaz de identificar as arestas que, ao serem removidas, dividem a rede em duas sub-redes, permitindo assim efetuar ligações que reduzam o risco dessa divisão. Além dos testes no modelo da rede brasileira, utilizaram-se também 1000 redes Scale-Free e 1000 aleatórias para verificar o aumento de eficiência trazidos. Todos os métodos foram capazes de aumentar a eficiência, tanto no modelo da rede real quanto nos modelos artificiais. A estratégia de ligar os vértices de betweenness mediano com auxílio do min-cut trouxe o maior aumento. A resiliência da rede, diante de falhas planejadas e falhas aleatórias, foi aumentada em poucos casos, porém, em nenhum houve redução da mesma. Conclui-se que as estratégias propostas podem ser utilizadas para melhorar a eficiência de redes de alta tensão, mantendo ou aumentando sua resiliência, bem como podem ser usadas para trazer os mesmos atributos para redes complexas em geral / Abstract: In this work we purpose to assess four methods to improve high-voltage networks resilience against failures and attacks, using the Complex Network Theory to do it. To test these methods, we created a network model in graph format, based on the Brazilian generation and transmission electrical network. The first of these methods consist in to link pairs of nodes which have the lowest degree in the network. The second creates a link betweenn the lowest betweenness nodes. The third method is to link the two lowest degree nodes which are linked to the highest load nodes. The last one creates a link betweenn the two nodes which has the median betweenness. All methods were tested with and without the use of the "min-cut" procedure. This procedure finds the lowest number of necessary links that, when removed, divide the network in two sub-networks. It allows us to identify these links and reduce the risk of this partitioning the network by adding new links. We also test the strategies in 1000 artificial Scale-Free networks and 1000 artificial Random networks to validate those methods. All strategies were able to increase efficiency, in the real and artificial networks models. The strategy which links the median betweenness nodes using the "min-cut" procedure brought the best results. The network resilience against planned and random failures was increased in in few cases, but no decreases was registered. We conclude that our strategies can be used to improve high-voltage network efficiency, keeping or improving its resilience, as they can be used to bring the same attribute to any type of complex networks / Mestrado / Tecnologia e Inovação / Mestre em Tecnologia
56

Resposta transitória no domínio do tempo de uma linha de transmissão trifásica considerando uma nova implementação do efeito pelicular = Time domain transient response analysis of three-phase transmission line considering a new skin effect model / Time domain transient response analysis of three-phase transmission line considering a new skin effect model

Monteiro, José Humberto Araújo, 1981- 05 September 2014 (has links)
Orientadores: José Pissolato Filho, Eduardo Coelho Marques da Costa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-25T04:23:41Z (GMT). No. of bitstreams: 1 Monteiro_JoseHumbertoAraujo_D.pdf: 2599049 bytes, checksum: 247f68cef0523b44c3d1e9c69dc48119 (MD5) Previous issue date: 2014 / Resumo: Este trabalho apresenta o desenvolvimento de um modelo de linha de transmissão trifásica utilizando uma nova implementação do efeito pelicular, além do estudo da resposta transitória obtida a partir do referido modelo quando surtos de manobra são simulados. A metodologia tradicionalmente utilizada para o cálculo da impedância interna de cabos sólidos cilíndricos faz uso das funções de Bessel, o que a torna complexa. A metodologia descrita por Gatous é tão precisa quanto a metodologia que utiliza as funções de Bessel e possui a vantagem de ser mais simples, visto que a solução final é um somatório cuja precisão depende da frequência estudada. O modelo desenvolvido neste trabalho emprega a metodologia de Gatous em uma linha de transmissão trifásica, cujos modos de propagação independentes são obtidos a partir da aplicação da matriz de Clarke. Para validar a metodologia de Gatous, foram calculadas a resistência e a indutância interna de cabos com raios variados em uma ampla faixa de frequências. Os resultados foram comparados aos obtidos a partir da metodologia tradicional. A metodologia de Gatous reproduziu com precisão a variação da impedância interna com a frequência. Para avaliar o funcionamento do modelo de linha de transmissão trifásico no domínio do tempo, um caso base foi estabelecido. Uma linha de transmissão trifásica de 69kV, circuito simples, foi submetida a chaveamentos de carga em duas situações distintas: chaveamento sendo executado no ponto de cruzamento com o zero da tensão e; chaveamento no ponto de 90° da tensão. Os transitórios de tensão e corrente foram obtidos a partir do modelo elaborado e comparados com os resultantes do software de análise de transitórios ATP. Os resultados alcançados reproduzem com fidelidade o comportamento transiente descrito pelo software supracitado / Abstract: This paper presents the development of a three-phase transmission line model using a new skin effect calculation and its transient response when some switching surges are applied to it. The methodology commonly used to calculate the internal impedance of solid conductors with cylindrical cross sectional area employs Bessel functions, which makes it a hard task to accomplish. Gatous, in his doctoral work, presented a new method to calculate skin effect impedance as accurate as Bessel¿s methodology with advantage of simplicity, whereas that final solution is an algebraic sum whose precision depends of frequency studied. The transmission line model developed in this work utilizes Gatous¿s method for skin effect impedance calculation in a three-phase transmission line, whose independent modes of propagation are obtained from the application of Clarke's matrix. In order to validate the mentioned methodology, internal resistances and inductances of cables with different size radii were calculated for a wide range of frequencies. The results were compared with those obtained through the traditional method, reproducing correctly the variation of the internal impedance with frequency. A base case was established to evaluate the operation of the three-phase transmission line in the time-domain model. A 69kV three-phase transmission line, single circuit, was subjected to switching load in two distinct situations: switching at zero crossing voltage and switching at voltage peak. Voltage and current transients were obtained from the developed model and compared with those derived from transient analysis software ATP. The results faithfully reproduced the transient behavior described by the above software / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
57

Falhas em linhas de transmissão elétrica na região sudeste do Brasil e efeitos do ambiente geofísico / Power transmission failures in southeastern Brazil and the effects geophysical environment

Duro, Magda Aparecida Salgueiro, 1968- 06 November 2013 (has links)
Orientadores: José Pissolato Filho, Pierre Kaufmann / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-23T01:41:59Z (GMT). No. of bitstreams: 1 Duro_MagdaAparecidaSalgueiro_D.pdf: 3861523 bytes, checksum: f5896319d2a3653a7903f977210f3ac1 (MD5) Previous issue date: 2013 / Resumo: A atual dependência da sociedade aos diversos sistemas tecnológicos em funcionamento na Terra traz uma constante preocupação pela sua vulnerabilidade a fatores menos conhecidos. As possíveis falhas no fornecimento de energia elétrica podem ocasionar transtornos de grande impacto às comunidades podendo acarretar perdas financeiras expressivas. Diversos fatores podem ocasionar falhas nas linhas de transmissão, entre eles, os fatores climáticos. Nesse contexto, são pouco conhecidas as influências qualitativas de distintos fatores, destacando-se os efeitos do denominado clima espacial. Há indicações que o clima espacial influencia a alta atmosfera terrestre, com repercussão no clima bem como em sistemas de engenharia em operação na Terra. As redes de transmissão de alta tensão representam um grande circuito elétrico pouco acima do solo sujeito a uma série de sobrecargas temporárias de vários tipos, algumas das quais podem levar a falhas. Algumas destas falhas podem estar relacionadas ao ambiente geofísico. Neste trabalho foi analisada uma base de dados sem precedentes de falhas em linhas de transmissão por um longo período (nove anos) numa grande malha localizada no Estado de São Paulo (sudeste do Brasil). O período estudado (1998-2006) compreende uma significativa fração do ciclo de atividade solar 23. A concessionária responsável (ISA.CTEEP) pela operação das linhas estudadas classifica as falhas em noventa e cinco tipos distintos de causas possíveis, sendo que a maior parte está relacionada às descargas atmosféricas. Este estudo está relacionado aos desligamentos devido às descargas atmosféricas, em duas redes de alta voltagem da companhia, de 138 kV e de 440 kV. No período estudado, estes desligamentos correspondem a 1.957 (42,80%) num total de 4.572 para a linha de 138 kV e de 170 (22,28%) sobre 763 para a linha de 440 kV. Equivale a menos de um a cada dez mil do número total de descargas atmosféricas ocorridas na mesma área, o que demonstra alta resiliência das redes de potência em relação aos raios. Durante a época das chuvas, há uma maior concentração de desligamentos. Para todo o período estudado houve redução de 67% e 77% no número de desligamentos devido às descargas atmosféricas, para as linhas de 138 kV e 440 kV, respectivamente, havendo uma boa correspondência com a redução do número de manchas solares. Nenhuma correlação foi encontrada em relação às atividades geomagnéticas caracterizadas pelo índice planetário (Kp) e pelas grandes tempestades (Dst) tanto em longos quanto em curtos prazos. Uma explicação sugerida associa a diminuição da atividade solar ao aumento da condutividade na atmosfera causada pelo maior fluxo de raios cósmicos. Consequentemente poderá ocorrer uma redução do limiar de voltagem necessário para produzir descargas atmosféricas para provocar desligamentos nas redes de alta voltagem. O circuito elétrico global descrito pelo acoplamento ionosfera-terra (a eletrosfera) exerce um papel importante para explicar a redução dos desligamentos. Com o aumento da condutividade atmosférica as descargas são menos potentes, resultando em menor número de desligamentos com o decréscimo do ciclo solar / Abstract: The current society dependence on the operating technological systems on the Earth brings a permanent concern for their vulnerability to not well known factors. Possible failures in electricity supply can cause inconveniences with large impact to the communities, which may cause significant financial losses. Different factors can cause failures in the transmission networks, including, climate factors. In this context, the influences of various qualitative factors, especially the effects of space weather are not well known. There are indications that space weather affects the upper atmosphere, with repercussions on the climate as well as in engineering systems in operation on Earth. High-voltage transmission networks represent large electrical circuits just above the ground which are subjected to a number of transient overcharges of various kinds, some of which may lead to failures. Some failures might be related to anomalies of the geophysical environment. In the present study we analyze a database consisting in a one unprecedented long series of transmission grid failures (nine years) on high-voltage networks located in São Paulo state (southeastern Brazil). The studied period (1998-2006) includes an important fraction of the solar activity cycle 23. The company responsible by the power grid operator (ISA.CTEEP) classifies causes in ninety-five distinct failure classes to explain the transmission grid shut downs. Most of the failures were attributed to atmospheric discharges. We have studied the failures attributed to atmospheric discharge, in the two power grids of the company, 138 kV and 440 kV. The failures attributed to atmospheric discharge correspond to 1.957 (42.80%) for a total 4.572 at 138 kV and to 170 (22.8%) out of 763 at 440 kV. They correspond to less than one ten thousandth of the actual number of atmospheric discharges recorded in the same area, demonstrating the grid's high resilience to breakdowns due to lightning. A clear concentration of failures in the region's thunderstorm season has been found. A significant 67% and 77% reduction in the number of failure rates has been found for the 138 and 440 kV grids, respectively, for the period studied, in good correspondence with the decay in the sunspot numbers. No obvious correlation was found between power failures and geomagnetic activity, represented by (Kp) the planetary index or major geomagnetic storms (Dst) in the period, either on short or on long time scales. One suggested explanation associates the decrease in solar activity to the increased conductivity in the atmosphere caused by increase cosmic ray flux. Consequently there may be a reduction in the threshold voltage necessary to produce discharge atmospheric to cause failures in high-voltage grids. The global electric circuit described by the ionosphere-ground coupling (the electrosphere), plays an important role in explaining the reduction the failures. With increase in conductivity atmospheric discharges are less potent, resulting in fewer failures with the decreasing solar cycle / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
58

Utilização de linhas de transmissão semelhantes no ensaio de energização de um tronco com pouco mais de meio comprimento de onda / Utilization of similar transmission lines on energization test of a trunk with a little more than a half-wavelength

Gomes, Elson Costa, 1986- 19 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T21:10:18Z (GMT). No. of bitstreams: 1 Gomes_ElsonCosta_M.pdf: 4986234 bytes, checksum: 3e2729d9cbec861f21c958f84db0b17e (MD5) Previous issue date: 2012 / Resumo: O transporte de grandes blocos de energia elétrica através de longas distâncias que variam de 2500 a 3000 km impõe a utilização de soluções mais adequadas baseadas em linhas de transmissão não convencionais. Uma alternativa em corrente alternada (CA) é a linha com pouco mais de meio comprimento de onda, que para o caso brasileiro, cuja frequência industrial é 60 Hz, apresenta comprimento físico de aproximadamente 2600 km. Por não existir no mundo um sistema similar em operação, foi proposta a realização da manobra de energização de um Elo CA Teste composto pela conexão em série de três interligações do sistema brasileiro que têm características elétricas semelhantes e que juntas formam um tronco de 2600 km. O presente trabalho visa avaliar a adequação de se utilizar um tronco formado por linhas semelhantes para representar um tronco de um pouco mais de meio comprimento de onda durante a manobra de energização da linha em vazio. Através de análise da resposta dos parâmetros das linhas no domínio da frequência e de simulações no domínio do tempo realizadas com os programas computacionais ATP e PSCAD/EMTDC para a avaliação de transitórios, observou-se que o uso do tronco proposto para o ensaio de energização é adequado e foram determinados valores limites para as diferenças entre características elétricas das linhas que podem compor sistemas com pouco mais de meio comprimento de onda, fornecendo importantes subsídios para a possível realização do referido ensaio em outros locais do mundo / Abstract: The transportation of large blocks of energy through very long distances between 2500 and 3000 km requires an extensive research for the best solutions based on non-conventional transmission systems. A very interesting alternative is the AC transmission with a little more than half-wavelength, which corresponds to a transmission line of 2600 km in systems like the Brazilian, with 60 Hz fundamental frequency. However, as there is no similar system in operation around the world, it was proposed a realization of the energization of an AC-Link Test composed of three interconnection trunks that have similar electrical characteristics that together can form a trunk of 2600 km. In this work it is evaluated the adequacy of using a trunk formed by similar lines to represent a line of a little more than a half wave-length during an energization maneuver. The response of AC-Link Test parameters in frequency domain and time domains simulations performed with the computer programs ATP and PSCAD/EMTDC, to evaluate transient response, showed that the proposed use of the trunk for the energization is appropriate. It was also identified limits for the differences between electrical characteristics of the lines that can form a trunk with a little more than a half-wavelength, contributing to the possible realization of the same test in other parts of the world / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
59

Implementação do religamento monopolar adaptativo rápido baseado na assinatura harmônica de tensão no simulador digital em tempo real (RTDS) / Implementation of fast adaptive single-phase reclosing based on measurement of harmonic content in the real-time digital simulator (RTDS)

Dias, Ozenir Farah da Rocha, 1988- 27 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-27T00:34:34Z (GMT). No. of bitstreams: 1 Dias_OzenirFarahdaRocha_M.pdf: 5023742 bytes, checksum: b0fe9b9418551d927583a884fbec6e92 (MD5) Previous issue date: 2015 / Resumo: Este trabalho apresenta a implementação de um esquema de religamento monopolar adaptativo rápido baseado na medição do conteúdo harmônico da tensão da fase aberta nas extremidades da linha de transmissão. O objetivo principal deste esquema é controlar e reduzir o tempo compreendido entre a abertura e o religamento da fase em falta, como também bloquear a manobra em caso de faltas permanentes. O esquema proposto foi implementado em um relé de distância e um medidor de conteúdo harmônico. O método está baseado na identificação do instante de extinção da corrente de arco secundário para casos de faltas transitórias. Já para faltas permanentes é implementado o bloqueio da manobra automática e a abertura tripolar do disjuntor da linha protegida. A medição do conteúdo harmônico foi feita primeiramente utilizando um medidor de qualidade de energia comercial, que realiza a medição do conteúdo harmônico de acordo com a norma IEC 61000-4-3. Em seguida, foi utilizado outro método de medição do conteúdo harmônico, chamado de filtro de medição do conteúdo harmônico rápido, elaborado dentro do Simulador Digital em Tempo Real (RTDS). O sistema de transmissão utilizado foi modelado no RTDS e seus dados são dados reais do sistema interligado nacional (SIN). As faltas monofásicas transitórias foram simuladas utilizando o modelo de arco do próprio RTDS. Já para falta permanente utilizou-se uma resistência de 1 'ômega'. O esquema foi avaliado através de testes variando o ponto de aplicação do defeito e o valor da corrente de arco secundário / Abstract: This work presents the implementation of a scheme of fast adaptive single-phase reclosing based on measuring the voltage harmonic content at the opened faulty phase terminals. The main objective of this scheme is to control and to reduce the time between opening and reclosing of the phase in fault, and also to block the maneuver in case of permanent faults. The proposed scheme is implemented in a distance relay and a harmonic content meter. The method is based in the identification of the secondary arc current extinction moment for transient faults cases. For permanent faults an automatic blocking followed by circuit-breaker three-phase opening is implemented. The measurement of harmonic content was made initially using a commercial power quality meter, which performs the harmonic content measurement according to IEC 61000-4-3 standard. Another harmonic content measurement method was tested, the fast harmonic content filter measurement, elaborated within the real-time digital simulator (RTDS). The transmission system used was modeled on RTDS and the data corresponds to an actual Brazilian 500 kV system. To represent the transient single-phase fault it was used RTDS arc model. The permanent fault was modeled with an 1'ômega' resistance. The scheme was evaluated by varying the fault application point and the secondary arc current value / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
60

Implementação de uma planilha excel destinada a análise de estabilidade de torres de transmissão de energia /

Silva, Fabiano Dias da. January 2018 (has links)
Orientador: Fernando de Azevedo Silva / Banca: José Elias Tomazini / Banca: Rosinei Batista Ribeiro / Resumo: O objetivo geral deste trabalho é a análise de estabilidade global de torres metálicas treliçadas de transmissão de energia utilizando o Método dos Elementos Finitos (MEF). Todo estudo foi baseado nas normativas da NBR-8800/2007 em que sugere-se uma análise de deslocabilidade da estrutura por meio dos parâmetros B2 e consequentemente a aplicação do MAES (método de amplificação de esforços), processo simplificado para análise dos efeitos globais de segunda ordem. Abordou-se o sistema elétrico brasileiro, descrição bem detalhada sobre tipos e modelos de torres, acidentes envolvendo torres de transmissão, treliças espaciais, método de análise estrutural, MEF, análise de estabilidade de estruturas, MAES e abordagem atualizada sobre o estado da arte em diversas universidades do mundo, em especial da China e Canadá, em que a grande preocupação é como simular nos projetos de torres de transmissão sobre efeitos climáticos como terremotos, tornados e furações por meio de modelos reduzidos em laboratório. Visando oferecer uma contribuição científica para o setor, desenvolveu-se uma planilha eletrônica no software Excel, devido a sua facilidade de utilização, acesso e capacidade de resolver cálculos matriciais facilitando a aplicação do MEF. A mesma foi validada com um software específico e consagrado na área de MEF, o SAP2000 e um software comercial de dimensionamento de estruturas metálicas usado em vários escritórios de projeto e consultoria estrutural, o METÁLICA 3D. A planilha cont... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The main objective of this project is the analysis of the global stability of the lattice towers of energy transmission using the FEM (finite element method). The whole study was based on NBR-8800/2007, normative where suggest a displaceability's analysis of the structures thought the B2 parameters and consequently the application of MAES' method, a simplified procedure for the analysis of second-order's global effects. In this project was approached the Brazilian electric system, a detail description of types and model of towers, accident involving transmission towers, space trusses, structural analysis' method, FEM, structure stability analysis, MAES' method. Also in this project, an updated approach the increase knowledge at this area in several universities all around the world, in special China and Canada, where the major concern is how to simulate at The transmission tower's project some climate effects such as earthquakes, tornadoes and hurricanes through reduced laboratory models. In order to offer a scientific contribution to this sector, a spreadsheet was developed in Excel software due to it facility of use, access and ability to solve matrix calculations, which facilitates the use of FEM. The same one was valid with a specific and consecrated software in the FEM area: The SAP2000; and commercial metal structural design software used in various design and structural consulting offices: the METÁLICA 3D. The spreadsheet contemplates pre-dimensioning of conductor cabl... (Complete abstract click electronic access below) / Mestre