• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 750
  • 196
  • 60
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1004
  • 461
  • 196
  • 151
  • 142
  • 108
  • 106
  • 104
  • 100
  • 92
  • 85
  • 76
  • 74
  • 73
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Développement d'outils bioanalytiques miniaturisés : greffage de biomolécules sur monolithes en capillaire couplés à la nanochromatographie pour l'analyse d'échantillons complexes / Development of miniaturized bioanalytical tools : grafting of biomolecules on monolithic capillaries coupled on-line to nanochromatography for the analysis of complex samples

Brothier, Fabien 24 October 2014 (has links)
L’analyse de traces dans des matrices complexes (environnementales, alimentaires ou biologiques) requiert très souvent une étape de purification et de préconcentration avant une analyse via des méthodes chromatographiques. Dans cette optique, des supports d’extraction basés sur des mécanismes de reconnaissance moléculaire ont été développés et appliqués à l’extraction de composés cibles rendant ainsi l’analyse plus sensible et plus fiable. Ces supports sélectifs peuvent entre autres résulter de l’immobilisation de biomolécules tels que les anticorps ou les aptamères (i.e. des oligonucléotides présentant une séquence capable de se lier spécifiquement à une molécule). Cette étape de traitement de l’échantillon est particulièrement nécessaire lorsqu’il s’agit de développer des systèmes séparatifs miniaturisés, tels que les microsystèmes séparatifs sur puce, du fait de la diminution de la résolution qui résulte de l’utilisation d’un canal de séparation de faible longueur. Dans ce contexte, ce projet de recherche a consisté à développer des systèmes bioanalytiques miniaturisés pour l’analyse de petites molécules ou protéines dans des échantillons complexes. Pour développer ces systèmes, la synthèse d’un monolithe hybride organique-inorganique in situ dans des capillaires de 100 µm d.i. a, dans un premier temps, été optimisée via une approche sol-gel puis caractérisée en termes de répétabilité. Dans une deuxième partie, deux toxines modèles de faible poids moléculaire ont été choisies : la microcystine-LR (MC-LR) et l’ochratoxine A (OTA). Des anticorps monoclonaux et des aptamères, spécifiques de l’une et l’autre des toxines ont ensuite été greffés sur des monolithes en capillaire. Les immuno- et oligoadsorbants miniaturisés obtenus (respectivement mIS et mOS) ont été couplés en ligne avec la nanoLC. La rétention spécifique des toxines cibles sur les mIS et mOS a été démontrée dans l’eau pure. La répétabilité de la synthèse et du greffage a été évaluée et la capacité de chacun des supports miniaturisés a été déterminée. Enfin, mIS et mOS ont été appliqués avec succès à l’extraction sélective de la MC-LR et de l’OTA à partir d’extraits de cultures de cyanobactéries, d’eaux environnementales ainsi que d’échantillons de bière dopés. Dans un troisième temps, de façon à transposer les outils sélectifs développés à l’analyse de protéines, des microréacteurs enzymatiques (IMER) ont été préparés par greffage de deux enzymes protéolytiques (pepsine et trypsine) sur des monolithes. Ces outils ont ensuite été couplés avec la nanoLC-MS² pour l’analyse d’une protéine modèle, le cytochrome C. Les rendements de digestion sur IMER se sont avérés présenter une bonne répétabilité. Toutefois, l’efficacité de la digestion sur les IMER à base de pepsine reste à ce jour insuffisante et nécessite de réadapter la procédure de greffage et/ou de digestion. / The analysis of ultra-traces from complex matrices (environmental, foodstuff or biological) often requires a step of purification and preconcentration before their analysis by chromatographic separation methods. Therefore, extraction sorbents based on a molecular recognition mechanism can be developed and used for the selective extraction of target molecules thus rendering their quantitative analysis in complex samples more reliable and sensitive. These extraction sorbents may result, among others, from the immobilization of biomolecules such as antibodies and aptamers (i.e. oligonucleotides whose sequence is specific for a target molecule). This selective sample pretreatment step is particularly necessary when developing miniaturized devices such as separative microsystems on chip because of the decrease of the resolution that results from the use of a shorter length separation channel. In this context, the aim of our study was to develop miniaturized bioanalytical devices for the analysis of small molecules or proteins in complex samples. For the development of these devices, in-situ synthesis of a porous hybrid organic-inorganic monolith in capillaries (100 µm i.d.) by sol-gel approach was firstly optimized and characterized in terms of repeatability. Secondly, two model toxins of low molecular weight were chosen: microcystin-LR (MC-LR) and ochratoxin A (OTA). Monoclonal antibodies and aptamers specific to one and the other target molecules were then grafted on the monolithic capillaries. The resulting miniaturized immunosorbent (mIS) and oligosorbent (mOS) were then coupled on-line to nanoLC. Specific retention of MC-LR and OTA on the mIS and the mOS, respectively, was demonstrated in pure water. Synthesis repeatability and capacity of the miniaturized sorbents were evaluated. Finally, these miniaturized tools were applied to the selective extraction of MC-LR or OTA from complex samples, i.e. blue-green algae extracts, environmental waters or beer. In a third part, immobilized enzyme reactors (IMERs) were prepared by grafting two proteolytic enzymes (pepsin and trypsin) on monoliths in order to transpose the developed selective tools to the analysis of proteins. These IMERs were then coupled on-line to nanoLC-MS² for the analysis of a model protein, cytochrome C. Digestion yields on IMERs presented a good repeatability. However, digestion efficiency on the pepsin-based IMERs remains so far insufficient and grafting or digestion procedure needs to be readjusted.
292

Etude des propriétés d'hyperthermie de nanoparticules dispersées dans des systèmes complexes / Study of hyperthermia properties of nanoparticles dispersed in complex systems

Guibert, Clément 10 July 2015 (has links)
L'hyperthermie magnétique est une technique de traitement de cancers en plein essor. Cette conversion d'une énergie électromagnétique en énergie thermique par des nanoparticules soumises à une excitation magnétique oscillant à haute fréquence est étudiée depuis près de deux décennies mais elle est encore mal décrite pour des systèmes complexes.Le travail présenté ici s'attache à compléter la connaissance de ce phénomène en reliant l'état de dispersion de nanoparticules à leurs propriétés d'hyperthermie.Tout d'abord sont présentés la caractérisation et le contrôle de dispersions dans des milieux complexes tels qu'un liquide ionique ou une matrice polymère.En effet, l'obtention d'une dispersion colloïdalement stable dans un liquide ionique soulève de nombreux défis. Une étude approfondie du rôle de la charge de surface des particules, contrôlée à l'aide du pH dans un liquide ionique protique, a permis de mieux comprendre le rôle du solvant et la nature des interactions dans ce type de milieu.En outre, disperser finement des nanoparticules hydrophiles dans une matrice hydrophobe telle qu'une matrice siliconée est également une tâche délicate et une méthode nouvelle d'évaporation d'émulsion ferrofluide-dans-matrice polymère est présentée ici, ainsi que l'étude des dispersions ainsi obtenues.Enfin est exposée une étude du pouvoir chauffant de nanoparticules dans des états de dispersion variés, faisant notamment intervenir une méthode de mesure développée dans le cadre de cette thèse. Ces résultats soulignent l'influence de l'agrégation des particules qui provoque une baisse significative de leur échauffement ainsi que le rôle clef de la compacité des agrégats formés. / Magnetic hyperthermia is a promising therapeutic technique against cancer. It consists in turning electromagnetic energy into heat thanks to nanoparticles that are excited by a radiofrequency oscillating magnetic field. Although this phenomenon has been studied for more than two decades, it remains poorly described. This work aims at filling the gap of knowledge about magnetic hyperthermia through the study of the correlations between the dispersion state and the heating efficiency of the particles. The characterisation and the control of dispersions in complex media such as ionic liquids or a polymer matrix is dealt with in the first part. Obtaining a colloidally stable dispersion in an ionic liquid proves indeed a challenging task. The particles surface charge can be controlled in a protic ionic liquid by tuning the pH. A thorough study of the influence of this parameter allowed a better insight into the role of the solvent and the nature of the interactions. Furthermore, the formation of a fine dispersion of hydrophilic nanoparticles in a hydrophobic silicon matrix is also a ticklish task. A new method is presented here, that consists in the evaporation of a ferrofluid-in-polymer matrix emulsion. The dispersion state of the resulting materials is then characterised.The heating efficiency of particles showing different dispersion states is studied in the last part. It includes results obtained with a new measurement method developed in the scope of this thesis. These results highlight that the particles aggregation causes a decrease of their heating properties. They also evidence the key role of the aggregates compactness in this respect.
293

Analyse rapide des actinides par couplage chromatographie liquide/ICP-MS et de 90Sr par compteur proportionnel à gaz, dans les échantillons de l'environnement, en situation post-accidentelle. / Rapid Analysis of actinides by liquid chromatography coupled on line to the ICP-MS and of 90Sr by a gas proportional counter, in environmental samples, in post-accidental situation

Habibi, Azza 07 December 2015 (has links)
La présente étude s’inscrit dans le contexte post-Fukushima et avait pour objectif la mise en place d’une méthode d’analyse pour identifier et quantifier, rapidement, des radionucléides émetteurs alpha et bêta, en situation post-accidentelle, dans les échantillons de l’environnement. La première étape de l’étude a permis de dresser la liste des radio-isotopes émetteurs alpha et bêta susceptibles d’être rejetés dans l’environnement suite à un accident nucléaire. Dans une deuxième étape, un protocole d’analyse rapide a été développé pour 17 radio-isotopes de U, Th, Pu, Am, Np et Sr. L’objectif était d’automatiser l’étape de séparation radiochimique et de la coupler à la mesure. La séparation est réalisée en employant des colonnes contenant les résines d’extraction, TEVA®, TRU et Sr. La mesure est effectuée par ICP-MS (spectrométrie de masse à plasma induit) et dans certains cas par compteur proportionnel à gaz pour quantifier le radiostrontium (89Sr et 90Sr). D’excellentes performances analytiques ont été obtenues, lors de la mesure hors-ligne, pour des échantillons d’eaux (robinet, rivière et mer) et solides (sols et filtres d’aérosols), après une minéralisation par four à micro-ondes ou par fusion alcaline suivie d’une co-précipitation avec Ca3(PO4)2. Ces performances sont caractérisées par des rendements de récupération compris entre 70 % et 100 % et des écarts types entre 5 % et 10 %. Le protocole de séparation a été ensuite automatisé et transposé en mode couplage en ligne avec l’ICP-MS. Les paramètres opératoires ont été optimisés avec un plan d’expériences, défini et exploité avec le logiciel Minitab®. Après optimisation du protocole, l’automatisation et le couplage de la séparation permettent de quantifier rapidement, en 1,5 h par échantillon, U, Th, Pu, Am, Np et Sr et de gagner un facteur 20 sur les limites de détection des radio-isotopes artificiels. / The present study follows the Fukushima power plant accident and aimed to develop an analytical method to achieve, during an emergency situation, a rapid identification and quantification of alpha and beta emitters in environmental samples. The first step of this study allowed us to list the alpha and beta emitters which can be released in the environment in case of a nuclear accident. The second step aimed towards the development of a rapid analysis method to quantify 17 radionuclides of U, Th, Pu, Am, Np and Sr. The main objective was the automation of the radiochemical separation step and its coupling for the measurement. The separation is performed using columns containing extraction resins, namely TEVA®, TRU and Sr. The measurement is performed using an ICP-MS (inductively coupled plasma mass spectrometry) and in some cases a gas proportional counter to quantify radiostrontium (89Sr and 90Sr). Excellent figures of merit were obtained, off line, with water (tap, river and sea water) and solid matrices (soil and aerosol filters), after a micro-wave digestion or an alkaline fusion dissolution followed by a Ca3(PO4)2 coprecipitation. The proposed analytical strategy showed yields between 70 % and 100 % and standard deviations between 5 % and 10 %. The newly developed separation method was then automated and coupled on-line to ICP-MS. The operating parameters were optimized using a design of experiments and the results were processed with Minitab®. The optimized automated separation coupled on-line to the ICP-MS allows the rapid quantification, in 1.5 h per sample, of U, Th, Pu, Am, Np and Sr with detection limits gain as high as 20 times for artificial radionuclides.
294

Optimisation énergétique de data centers par utilisation de liquides pour le refroidissement des baies informatiques / Data center energy optimization using liquids to cool computer racks

Douchet, Fabien 17 December 2015 (has links)
Les data centers sont des infrastructures qui hébergent un grand nombre d’équipements informatiques. Plus de 99% de la puissance électrique consommée par les composants électroniques est transformée en chaleur. Pour assurer leur bon fonctionnement il est donc nécessaire de les refroidir. Cette opération est majoritairement réalisée par l’emploi de systèmes de climatisation à air très énergivores. De plus, la densité de puissance dissipée au sein des baies informatiques est en augmentation permanente. Nous arrivons alors aux limites de l’utilisation de l’air comme fluide caloporteur pour le refroidissement. Les études réalisées durant cette thèse concernent l’amélioration de l’efficacité énergétique des systèmes de refroidissement des baies électroniques par l’exploitation de liquides comme fluides caloporteurs. Cette approche permet de bénéficier de coefficients d’échanges thermiques et de capacités de refroidissement plus importants, avec des perspectives plus viables pour la revalorisation de la chaleur issue des data centers.Durant la thèse, quatre solutions de refroidissement ont été évaluées. Des expérimentations ont été menées à l’échelle de serveurs et d’une baie informatique. Une instrumentation conséquente permet de mettre en évidence le bon refroidissement des composants et de déterminer des indicateurs d’efficacité énergétique des systèmes étudiés. A partir des résultats expérimentaux, deux modèles numériques sont développés par une approche nodale et une identification des paramètres par méthode inverse. Ces modèles pourront être dupliqués à l’échelle d’une salle informatique afin de quantifier les gains potentiels de deux solutions de refroidissement liquide. / Data centers are facilities that house a large numbers of computer equipment. More than 99% of the electrical power consumed by the electronic components is converted into heat. To ensure their good working, it is necessary to keep them under their recommended temperatures. This is mainly achieved by the use of air conditioning systems which consume a lot of electrical power. In addition, the power density of computer racks is constantly increasing. So the limits of air as a coolant for electronic equipment cooling are reached.Studies conducted during this thesis concern the improvement of energy efficiency of cooling systems for electronic rack by using liquids as heat transfer fluids. This approach gives higher heat exchange coefficients and larger cooling capacity with more viable aspects for the recovering of heat from data centers.Four cooling solutions are evaluated. Experiments are conducted on several servers and on a computer rack. A consistent instrumentation helps to highlight the efficiency of components cooling and allows us to identify energy efficiency indicators of the studied systems. From the experimental results, two numerical models are developed by a nodal approach and a parameter identification by inverse method is carried out. These models can be duplicated at the scale of a data center room in order to quantify the potential gains of two liquid cooling solutions.
295

Biomateriaux collagène / gélatine : des phases cristal-liquides aux matériaux hybrides / Collagen/gelatin biomaterials : from the liquid crystal phases to the hybrid materials

Portier, François 18 October 2016 (has links)
L’objectif de cette thèse a consisté à étudier in vitro des phénomènes d’auto-assemblage de molécules de collagène de type I natif, dénaturé ou modifié. Dans une première partie, nous avons analysé des solutions denses en milieu acide de collagène I et de gélatine A par microscopie à lumière polarisée et microscopie SHG résolue en polarisation (P-SHG). Nous avons ainsi mis en évidence la première mésophase obtenue à partir de gélatine. Nous avons ensuite étudié l’impact de la gélatine sur des mésophases en contre-plaqué de collagène I et montré que le collagène pouvait être subtilisé par la gélatine à hauteur de 20% sans en affecter la formation des phases en contre-plaqué. Les matrices collagène/gélatine obtenues après fibrillogenèse ont été caractérisées à différentes échelles en ayant recours à la calorimétrie différentielle (DSC), à la microscopie électronique à transmission (MET), au P-SHG et l’imagerie par résonnance magnétique (IRM). Nous avons montré que ces matrices présentent une structuration hiérarchique de type fractal et que la gélatine stabilise le collagène.Dans la seconde partie, nous nous sommes intéressés aux propriétés d’auto-assemblage de molécules de collagène I modifié avec de la rifamycine SV pour la synthèse de gels à délivrance contrôlée. Nous avons utilisé différents modes d’assemblage afin d’arriver à notre but et avons caractériser les propriétés chimiques, rhéologiques et antibiotiques des gels obtenues. Pour mieux comprendre le système, nous avons étudié la structure des assemblages de collagène modifié au sein d’un système dilué à l’aide du cryo-MET et de la microscopie à force atomique couplé à la spectroscopie infrarouge (AFMIR). / The object of this thesis was to study the in vitro self-assembly phenomena of native, denatured or modified collagen type I.In the first part, we analysed dense solutions of collagen I and gelatin A (in acidic medium) by polarized light microscopy and polarization resolved SHG microscopy (P-SHG). We have thus observed the first mesophase obtained from gelatin. We then studied the impact of gelatin on collagen I plywood mesophases and showed that collagen could be replaced by gelatin up to 20% without affecting the formation of the plywood phases.Collagen/gelatin matrices obtained after fibrillogenesis were characterized at different scales by using Differential Scanning Calorimetry (DSC), Transmission Electron Microscopy (TEM), P-SHG and Magnetic Resonance Imaging (MRI). We showed that these matrices have a hierarchical structure of fractal type and that gelatin stabilizes collagen.In the second part, we studied the self-assembly of collagen I modified with rifamycin SV for the synthesis of controlled delivery gels.We used different methods of assembly in order to reach our goal and we characterized the chemical, rheological and antibiotic properties of the obtained gels. To better understand the system, we studied the structure of modified collagen assemblies in a diluted systems with cryo-TEM and atomic force microscopy coupled with infrared spectroscopy (AFMIR).
296

Quantification de protéines dans des matrices complexes par spectrométrie de masse : nouveaux outils et apllications / Protein quantification in complex matrices by mass spectrometry : new tools and applications

Rougemont, Blandine 01 July 2016 (has links)
La spectrométrie de masse en tandem est désormais une technique de choix pour l'analyse du protéome humain ou de micro-organismes. Typiquement, les protéines sont tout d'abord digérées en peptides protéotypiques, ceux-ci étant ensuite séparés par chromatographie liquide avant d'être analysés par MS/MS. L'identification et la quantification de ces peptides rapporteurs de protéines permet la mise en évidence d'un phénotype ou d'un mécanisme cellulaire particulier, dans un organisme complexe. Des approches par spectrométrie de masse ciblée et non ciblée coexistent et sont complémentaires dans l'analyse protéomique. Les travaux présentés ici se sont focalisés sur le développement de méthodes ciblées, et plus particulièrement en mode SRM, à travers deux applications chez des micro-organismes modèles. Ainsi, une première étude s'est portée sur la quantification absolue des protéines du virus chimère dengue – fièvre jaune candidat vaccin. Par l'utilisation d'une stratégie de quantification de type AQUA, nous avons pu développer, valider et transférer le dosage des quatre sérotypes du virus chimère candidat vaccin. Les problématiques soulevées à travers ce projet nous ont amené à proposer des étapes à contrôler lors du développement d'un dosage par la stratégie AQUA.Dans une seconde partie, nous nous sommes attachés à développer une analyse quantitative sans marquage de 445 protéines afin d'étudier l'infection d'un phytopathogène, Dickeya dadantii, sur une plante modèle. Afin d'assurer un transfert simple et rapide de cette analyse multiplexée, nous proposons un nouvel outil d'acquisition indépendant des temps de rétention. Cet outil développé en partenariat avec la R&D Sciex à Toronto est appelé « Scout-MRM » / Tandem mass spectrometry is now a technique of choice for human or micro-organisms proteome analysis. Typically, proteins are first digested into surrogates’ peptides, separated by liquid chromatography before being analyzed by MS/MS. The ultimate goal is the identification and the quantification of these peptides, belonging to proteins and highlighting a phenotype or a cellular mechanism in a complex organism. Both targeted and untargeted approaches are used and are complementary in proteomic analysis. The work presented here is focused on the development of targeted methods, and more particularly in the SRM mode, through two applications involving micro-organisms. So, the first study concerned to absolute quantification of viral proteins of the chimeric yellow-dengue fever, vaccine candidate against dengue. By using the AQUA quantification strategy, we were able to develop, to validate and to transfer the method for the four chimeric virus serotypes. Then, problems met during development process, lead us to suggest check points to verify when using AQUA strategy. In a second part, we attempted to develop a quantitative label free analysis of 445 proteins to study the infection of the phytopathogen Dickeya dadantii, on a model plant. To ensure a simple and fast transfer of this multiplex, we purpose a new acquisition tool, independent from retention time. This tool was developed in a partnership with the R&D Sciex, Toronto and is called “Scout-SRM”
297

Développement d'un microreacteur plasma pour la synthèse chimique / Development of a plasma microreactor for chemical synthesis

Zhang, Mengxue 22 November 2016 (has links)
La manipulation d'espèces radicalaires de haute énergie dans des conditions expérimentales de sécurité, et qui permet la prédictibilité et l'efficacité des processus engagés demeure un défi en synthèse moléculaire. Pour relever ce défi et développer ainsi de nouvelles voies de synthèses plus propres, notamment en limitant le nombre d’étapes et la consommation en solvants et en catalyseurs, l’équipe Procédés, Plasma, Microsystèmes de Chimie ParisTech développe au sein de l’Institut Pierre-Gilles de Gennes des réacteurs plasma gaz-liquide micro-structurés. Dans cette thèse, des procédés de microfabrication ont été développés afin d’élaborer des microréacteurs diphasiques avec plasma intégré. Deux types de microréacteurs sont présentés dans cette thèse. Le premier type de réacteur utilise des géométries permettant de générer des micro-bulles dans un flux de liquide. Les résultats expérimentaux ont pu démontrer la formation d’un plasma au sein de ces systèmes. Cependant, le transfert des radicaux à l’interface reste assez faible selon une modélisation numérique. Un deuxième microréacteur contenant des cavités de gaz a été ensuite conçu. La phase gazeuse reste immobile tandis que la phase liquide progresse dans le microcanal. Le transfert de radicaux de la phase gazeuse vers la phase liquide a été mis en évidence (réaction de fluorescence), et la nature et quantité des radicaux ont été déterminées (réaction de spin-trapping). Ces résultats ont pu être confrontés à ceux d’une simulation numérique en utilisant le logiciel COMSOL Multiphysics. / Recently, organic synthesis by plasma technology is drawing more and more attention to chemists. The generation of a plasma leads to various reactive species (electrons, radicals, and positive and negative ions, etc.) which can therefore promote various chemical reactions. Engaging fewer reactions and catalysts and consuming less solvent, plasma-assisted reactions open up new and cleaner routes for organic synthesis. To control the selectivity of the radical reaction, it is necessary to precisely control the concentration of reactants and products, and be able therefore to inject or extract precisely chemical compounds in the reactive medium. As a consequence, microfluidics, known for its precise handling of fluid hydrodynamics, could be an ideal tool to control the reactivity of the radical species. In this study, a novel plasma-integrated microfluidics device has been developed with the objective to perform chemical synthesis. After a first step of electrode optimization and geometry optimization, a cavity plasma microreactor was conceived using rapid prototyping techniques. When the reactant is in the liquid phase, a key point is the radical transfer process from the plasma medium to the liquid phase. This transfer process was evaluated by means of electron paramagnetic resonance spectroscopy and fluorescence measurements. Experimental results show that the migration of various radical species (H and ∙OH) from gas to liquid phase was achieved. Moreover, the COMSOL numerical tool has also been employed to evaluate and assess both the radical transfer and plasma discharge processes in the microreactor.
298

Synthèse d'une cornée artificielle à base de collagène I / Synthesis of a collagen based artificial cornea

Tidu, Aurélien 29 September 2016 (has links)
L'objectif du projet est la synthèse d'une cornée artificielle biocompatible à base de collagène de type I extrait et purifié à partir de tendons de queues de rats. La synthèse utilise les propriétés mésogènes (cristal-liquides) de la molécule de collagène ainsi qu'une transition sol-gel mimant l'étape de fibrillogenèse qui se déroule in vivo. Des solutions acides de collagène (500 mM en acide acétique) sont dyalisées contre des solutions de diverses concentrations en acide acétique et en acide chlorhydrique puis concentrées jusqu'à 90 mg/mL. Les phases cristal-liquides données par les différentes conditions physico-chimiques sont analysées par microscopie à lumière polarisée et par génération de seconde harmonique. L'une des conditions permet d’obtenir une phase dite en contreplaqué, ce qui est l’organisation des lamelles de fibrilles de collagène dans la cornée.Analysée par microscopie électronique à transmission, la structure des matrices obtenues après fibrillogénèse présente des domaines en contreplaqué indiquant une conservation et une stabilisation de l’organisation cristal-liquide d'origine. L’organisation obtenue est proche de celle du stroma cornéen. Par une optimisation des conditions physico-chimiques, les matrices synthétisées présentent une transparence proche de 90 % et possèdent de bonnes propriétés mécaniques avec un module d’Young proche de 1 MPa. Des cultures cellulaires effectuées sur les matrices transparentes montrent qu’elles sont un très bon support pour la culture de cellules cornéennes, en particulier des cellules épithéliales. Tous ses résultats confortent la méthode utilisée et les essais in vivo constituent l’étape suivante. / In view to generate artificial corneas, dense transparent collagen type-I scaffolds were synthesized exploiting the intrinsic liquid crystals properties of collagen molecules. 3 mg/mL collagen solutions in 500 mM acetic acid were dialyzed against a solution of precise concentrations in acetic and hydrochloric acid. When concentrated, solution provided a liquid-crystal organization resembling plywood, which is the organization of the collagen fibrils in the cornea. This was verified by polarized light and second harmonic generation microscopy experiments. In parallel these collagen solutions were also concentrated by centrifugation-filtration up to 90 mg/mL. The concentrated solutions were pressed into cornea-like shape and submitted to ammonia vapor in order to induce the fibrillogenesis of collagen. The result is a transparent dense fibrillated collagen matrix (transparency 90 %). Transmission electron microscopy revealed that fibrils kept the organization of the concentrated solution. Using a custom made device, mechanical tests showed that the Young modulus reached 900kPa. Human donor limbal explants were sewed on top of the scaffolds and cultured for 14 days. Optical microscopy and immunocytochemical analysis showed the development of an epithelium with characteristics of corneal epithelial cells. Preliminary experiments showed that keratocytes could be successfully inserted during the synthesis process. Thus, the results show the viability of the process of fabrication, and the following step is the in vivo experiment.
299

Production of graphene based materials and their potential applications / Synthèse de matériaux à base de graphène et leurs applications potentielles

Celik, Yasemin 26 February 2015 (has links)
Le graphène est un matériau prometteur pour de nombreuses applications du fait de ses propriétés exceptionnelles. Cependant, à la fois les propriétés et les rendements des graphènes et dérivés sont très variables et dépendants de la méthode de production utilisée. De ce fait, la méthode de production doit être développée en accord avec les besoins liés à l'application visée. Dans cette thèse, différents nanomatériaux dérivés du graphène ont été préparés en employant deux méthodes différentes, l'exfoliation en milieu liquide et la synthèse directe par dépôt chimique catalytique en phase vapeur (CVD), et une compréhension fondamentale sur la production de graphène a été acquise. Ces deux méthodes sont prometteuses en termes de qualité, de possibilité de production à grande échelle, de cout de production et enfin d'applications des différents "graphènes" obtenus. D'une part, l'exfoliation en milieu liquide permet de produire des dérivés du graphène tels que le few-layer graphene (FLG (<5 feuillets)) à relativement grande échelle, pour des applications telles que les nanocomposites. Le défi principal consiste à augmenter la concentration en FLG autant que possible, tout en conservant une bonne qualité. De ce fait, une étude comparative de l'exfoliation dans l'alcool isopropylique de 3 poudres de graphite différentes a été entreprise. Des suspensions de FLG de concentration élevée (?1,1 mg/ml) ont été obtenues en partant de poudre de graphite de surface spécifique élevée, par sonication dans l'alcool isopropylique (cuve, 90 min). Ces nanoparticules ont ensuite été incorporées dans des nanocomposites à matrice alumine. Ainsi, nous avons préparé par frittage SPS des nanocomposites à matrice céramique possédant des propriétés mécaniques, thermiques et électriques anisotropes. D'autre part, des films de graphène alliant une grande surface, prometteurs pour des applications dans le domaine de l'électronique, ont été synthétisés par CVD basse pression sur des feuilles de Cu. L'influence de l'atmosphère pendant le traitement thermique et la nature du catalyseur sur le niveau d'impuretés, la qualité des films de graphène synthétisés et leur uniformité en termes de nombre de feuillets a été étudiée. Des films de graphène CVD de haute qualité (très peu de désordre de structure) ont été utilisés pour la réalisation de dispositifs. Ces derniers ont été caractérisés à température ambiante en mesurant leur résistance électrique en fonction de la tension grille ainsi que par des mesures de transport en régime d'effet Hall quantique (basse température et forts champs magnétiques - pulsés). Les résultats préliminaires obtenus confirment que du graphène mono-feuillet possédant une bonne mobilité électronique atteignant jusqu'à 46500 cm²/Vs à température ambiante a pu être synthétisé avec succès. / Graphene is a promising material for many applications due to its unique properties. However, properties and yield of graphene-based materials show variations depending on which production route is used. Therefore, an appropriate production method has to be preferred according to the requirements of a specific application. In this thesis study, graphene-based materials have been successfully produced by liquid phase exfoliation (LPE) and chemical vapor deposition (CVD), which are promising graphene production methods in terms of quality, scalability, cost and applicability of the produced material to relevant applications, and a fundamental understanding on graphene production has been developed. LPE route allows one to produce graphene-based materials at a large-scale for applications such as nanocomposites. The challenge of this method is to increase graphene concentration as much as possible while maintaining the quality of the graphene flakes. Therefore, a comparative study, at which three different graphite-based powders were investigated as starting materials for an effective exfoliation process in isopropyl alcohol (IPA), was performed. High concentration (?1.1 mg/ml), few-layer (?5 layers) graphene-based dispersions were prepared by sonication in IPA within 90 min by utilizing a high surface area graphite nano-powder. This graphene-based material was then incorporated into Al2O3 matrix nanocomposites as a reinforcing/filler phase. Ceramic matrix nanocomposites which exhibit anisotropic mechanical, thermal and electrical properties have been successfully prepared by spark plasma sintering. On the other hand, large-area graphene films, which are promising for electronic applications, were synthesized via low-pressure CVD method over Cu-foils. The influence of ramping atmosphere and Cu foil characteristics on the impurity level, quality of the synthesized graphene films and their thickness uniformity was investigated. High quality CVD-grown graphene films with a significantly reduced disorder level were used for device fabrication and characterized in terms of their electrical resistance at room temperature as a function of gate voltage and transport property measurements in Quantum Hall Effect (QHE) regime (at low temperature and high magnetic field) by pulsed magnetic field experiments. The preliminary results confirmed that single layer graphene with a relatively high electronic mobility reaching up to ?46500 cm2/Vs at room temperature was successfully produced.
300

Liquides ioniques sous confinement nanométrique unidimensionnel / Ionic liquids under 1D nanometric confinement

Ferdeghini, Filippo 20 October 2015 (has links)
L'idée à la base de ce projet est de mettre à profit le confinement nanométrique unidimensionnel pour décupler la conduction ionique des électrolytes et donc la puissance des accumulateurs au lithium. Nous avons concentré nos efforts sur une classe particulière d'électrolytes qui, en raison de leurs stabilités physique et électrochimique, ont été identifiés comme prometteurs: les Liquides Ioniques (LI). Nous avons confiné les LI dans deux systèmes poreux présentant une topologie commune (pores cylindriques macroscopiquement orientés) mais aux propriétés physico-chimiques complémentaires: i) des alumines poreuses (AAO, interface hydrophile, diamètre des pores de 25 à 160 nm) et ii) des membranes de NanoTubes de Carbone (NTC, interface hydrophobe, diamètre des pores 4 nm).Nous avons développé un modèle microscopique multi-échelle original, prenant en compte la dynamique complexe des cations des LI: combinaison i) de la dynamique de réorientation rapide des chaînes latérales alkyle, ii) de la diffusion de la molécule au sein des agrégats nanométriques spontanément formés par les LI, puis iii) de la diffusion entre ces agrégats. Ce modèle reproduit de façon remarquablement robuste les données de diffusion quasi-élastique de neutrons sur une gamme étendue de vecteurs de diffusion (0,1 à 2,5 Å-1) et de temps (10-1 à 2.103 ps). A cette échelle locale, nous ne détectons pas d'influence du confinement sur la dynamique du LI confiné au sein des AAO et des CNT. Nous montrons cependant qu'à l'échelle microscopique (PFG-NMR) et macroscopique (spectroscopie d'impédance) le confinement des LI au sein des NTC permet d'obtenir un gain de conductivité d'un facteur 3. Un brevet est déposé. / The idea behind this project is to exploit the 1D nanometric confinement in order to increase the electrolytes ionic conductivity and, thus, the power of the lithium accumulators. We have focus on a specific class of electrolytes, which, owing to their physical and electrochemical stabilities, have been identified as very promising: the Ionic Liquids (ILs). We have confined the ILs in porous systems having a common topology (cylindrical pores macroscopically oriented), but with complementary physico-chemical properties: i) the porous alumina (AAO, hydrophilic interface, pores diameter between 25 and 160 nm) and ii) Carbon NanoTubes based membranes (CNT, hydrophobic interface, pores diameter of 4 nm).We have developed an original microscopic multiscale model, taking into account the complex dynamics of ILs cations: combination of i) fast reorientation dynamics of side alkyl-chains, ii) molecule diffusion within nanometric aggregates spontaneously formed in the ILs and iii) diffusion between the aggregates. This model reproduces in a very robust way the quasi-elastic neutrons scattering data on an extent interval of wave vector (0.1 à 2.5 Å-1) and time (10-1 à 2.103 ps). At this local scale, we do not observe any influence due to the confinement on the dynamics of the ILs confined in the AAO and CNTs. We show however that at microscopic (PFG-NMR) and macroscopic (impedance spectroscopy) scale the ILs confinement within the NTCs allows to obtain a conductivity gain of factor 3. A patent is filed.

Page generated in 0.0568 seconds