• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Selantes de fossulas e fissuras : avaliação clinica e laboratorial

Pardi, Vanessa 29 January 2004 (has links)
Orientadores: Antonio Carlos Pereira, Mario A. Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T18:50:53Z (GMT). No. of bitstreams: 1 Pardi_Vanessa_D.pdf: 2278132 bytes, checksum: 707d334aa58b758590632e60e1480f0b (MD5) Previous issue date: 2004 / Resumo: Selantes de fissuras têm sido considerados eficazes na prevenção de cárie oclusal, entretanto há controvérsias na literatura quanto ao material de escolha para o procedimento de selamento. Desse modo, o presente trabalho composto por 4 artigos tem como objetivos: I) descrever o desempenho dos selantes de fóssulas e fissuras ao longo dos anos e discutir sua importância como método preventivo; 2) avaliar clinicamente 3 diferentes materiais aplicados como seiantes de fissuras (Vitremer, Dyract Flow e Revolution) após 2 anos de aplicação clínica; 3) comparar, in vitro, o desgaste e mudanças na rugosidade superficial de 4 materiais odontológicos (Delton, Filtek Flow, Dyract Flow e Vitremer) aplicados como selantes após abrasão por escovação e dentifrício; 4) avaliar, in vitro, a infiltração marginal em seiantes de fissuras realizados com diferentes materiais odontológicos (Delton, Filtek Flow, Dyract Flow e Vitremer). Em relação à revisão sobre selantes, foi concluído que eles são eficazes na prevenção de cárie e suas indicações e contra-indicações devem ser cuidadosamente avaliadas pelos profissionais. Os resultados após dois anos de aplicação clínica permitiram concluir que a resina composta de alto escoamento Revolution apresentou a melhor taxa de retenção, embora não tenha havido diferença estatisticamente significante em relação à presença de cárie entre os grupos. Quanto à resistência à abrasão, não houve diferença estatisticamente significante entre os materiais Vitremer e Dyract Flow e nem entre Filtek Flow e Delton, entretanto os primeiros apresentaram maior taxa de desgaste. O material Vitremer apresentou o maior valor de rugosidade, enquanto o material Delton apresentou o menor valor após o teste de abrasão. Em relação ao teste de microinfiltração, embora todos os materiais estudados tenham apresentado um certo grau de microinfiltração, não houve diferença estatisticamente significante entre os mesmos. O contínuo estudo de materiais odontológicos para a aplicação como selantes de fissuras é recomendado, uma vez que avanços tecnológicos podem contribuir para a melhora das propriedades físicas dos materiais e, conseqüentemente, para a melhora de seu comportamento clínico / Abstract: Fissure sealants had been considered efficacious on occlusal caries prevention, however there are controversies in the literature with regard to the material to apply. This present study, composed by four articles, has the following aims: a) to describe the performance of the fissure sealants and to discuss their relevance as a preventive method; b) to evaluate three different materiaIs (Vitremer, Dyract Flow and Revolution) used as an occlusal sealant after 2-year clinical application; c) to compare the in vitro wear and changes on the superficial roughness of different materiaIs (Delton, Filtek Flow, Dyract Flow e Vitremer) used as fissure sealant after abrasion with toothbrush and dentifrice and d) to evaluate the in vitro microleakage of different materiaIs used as fissure sealants (Delton, Filtek Flow, Dyract Flow e Vitremer). Regarding the review (a), it was concluded that the fissure sealant is efficacious on caries prevention and the indications and contraindications of this proceeding should be carefully evaluated by professionals. In the 2-year clinical evaluation (b) was verified that Revolution showed the best retention rate, however there was no statistically significant difference with regard to caries presence after the evaluated period among the groups (Revolution, Dyract Flow and Vitremer). With reference to the abrasion test (c), there were no statistically significant difference either between Vitremer and Dyract Flow or Filtek Flow and Delton, however the former showed the highest wear before the abrasion test. Vitremer showed the highest roughness measurement, while Delton showed the lowest measurement after the abrasion test. Regarding the microleakage test (d), although all the materiaIs had exhibited some degree of microleakage, there were no statistically significant difference among them. A continuous study of dental materiaIs to apply as fissure sealants is recommended, since that technological advances can contribute to the improvement of physical properties of dental materiaIs and consequent1yto the improvement of their clinical behavior / Doutorado / Cariologia / Doutor em Odontologia
122

Efeito da associação composito-materiais resilientes sobre a resistencia da união dentina/composito em modelos experimentais bi e tridimensionais

Santos, Alex Jose Souza dos 15 December 2003 (has links)
Orientador: Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T22:58:40Z (GMT). No. of bitstreams: 1 Santos_AlexJoseSouzados_D.pdf: 5116499 bytes, checksum: f65e728e88daf4b8db91116fb4821145 (MD5) Previous issue date: 2003 / Resumo: O objetivo deste estudo foi avaliar o efeito do tipo de compósito e da camada elástica sobre a resistência da união dentina/compósito em modelos bi e tridimensionais. O esmalte oclusal de 96 molares humanos foi removido expondo a superfície plana de dentina na qual foram preparadas cavidades Classe I (Fator C = 4,5; dimensões= 4 mm M-D, 3 mm V -L e 3 mm de profundidade). Dezoito grupos experimentais (n=4) foram distribuídos pela combinação de três compósitos: SureFil, Filtek Z250 e Z100; e de seis diferentes camadas elásticas: 1- SB(lc), camada única do adesivo Single Bond; 2- SB(3c), três camadas do adesivo Single Bond; 3- SB+SBMP, uma camada de SB associada a duas camadas adicionais do adesivo Scotchbond Multi Purpose; 4- OS, aplicação de uma camada do adesivo OptiBond Solo Plus; 5- SB+PLF, uma camada de SB associada ao compósito de alto escoamento Protect Liner F; e 6- SB+FF, uma camada de SB associada ao compósito de alto escoamento Filtek Flow. Cada camada adicional de adesivo foi fotoativada separadamente. Após a criação da "camada elástica", o compósito foi inserido em incremento único. Seis grupos adicionais foram obtidos a partir da união do compósito Esthet-X à parede livre de dentina vestibular (Fator C= 0,22; contração efetiva), seguindo os mesmos seis tipos de "camada elástica" realizados no modelo cavitário. As amostras foram armazenadas em água destilada a 37°C, por 24 h, antes do teste de tração. Os dentes foram preparados para microtração realizada numa máquina de ensaio universal (Instron 4411). Foram obtidos 4 palitos de cada dente (A _ 0,8 mm2), removidos da parede dentinária vestibular e testados a velocidade de 0,5mm/min. Os dados foram analisados pela análise de variância ANOV A e as médias de resistência de união (MRU) comparadas pelo teste de Tukey e Teste Dunnett ao nível de 5'0 de significância. As MRU variaram entre 11,2 e 29,6 MPa. Foi verificada diferença estatística entre as MRU para os diferentes compósitos (p= 0,0079) e entre as diferentes camadas elásticas tanto em cavidade (p< 0,0001) quanto parede-livre (p= 0,0095). O compósito Z250 apresentou, de forma geral, as maiores MRU com diferenças estatísticas daquelas apresentadas pelo compósito Z100. O compósito SureFil obteve resultados intermediários, sem diferenças estatísticas dos outros dois. No modelo cavitário, as MRU para o Z250, Z100 e SureFil foram respectivamente: SB+SBMP (27 / 22,9 / 20,4)a, SB+PLF (19,8 / 21,3 / 18,5)ab, SB+FF (21,3 / 19 / 15,4)bC, SB-3c (17,9 / 16,4 / 14,2)bC, 05-1 c (15,9 / 14,2 / 16)bC e SB-1c (17 / 14,8 / 11, 2)C . Os valores de resistência de união foram menores quando produzidos num modelo cavitário e dependentes do tipo de compósito e "camada elástica" formada. A associação do compósito Z250 às "camadas elásticas" SB+SBMP, SB+PLF, SB+FF e SB(3c) e a associação do compósito SureFil a SB+PLF foram capazes de produzir MRU, no modelo cavitário, semelhantes estatisticamente àquelas desenvolvidas quando o compósito foi submetido à "contração efetiva". Conclui-se que a utilização de compósitos de baixa viscosidade e de camadas espessas de adesivo, como camada intermediária, pode funcionar como uma zona de absorção de tensões, preservando a união e promovendo aumento dos valores de resistência da união dentina/compósito em cavidades Classe I / Abstract: T he aim of this in vitro study was to assess the effect of different { resin composites and elastic layers on resin/dentin bond strength on " the buccal wall of Class I cavities. Ninety-six caries-free third molars were ground flat to expose the dentin surface under running water. Class I cavities (C-factor = 4.5, 4 mm mesial-distal, 3 mm buccal-lingual and 3 mm deep) were prepared in occlusal dentin and then randomly distributed into eighteen experimental groups by changing of three resin composites (SureFil, Filtek Z250 e Z100) and six elastic layers: 1SB(lc), Single Bond adhesive was applied of according manufacturer instruction's; 2- SB(3c), Single Bond adhesive received two additional coats; 3- SB+SBMP, Single Bond adhesive received two additional coats of Scotchbond Multi-Purpose adhesive; 4- OS(lc) Optibond Solo Plus adhesive was applied of according manufacturer instruction's; 5- SB+PLF, Single Bond adhesive received intermediate layer of low-viscosity composite Protect Liner F; and 6- SB+FF, Single Bond adhesive received intermediate layer of low-viscosity composite Filtek Flow. Each additional adhesive layer was individually light-cured. After created elastic layer, the composite was placed using a bulk-filling increment. The teeth were prepared for microtensile bond strength (IlTBS) with the bonded beams (of approximately 0.8 mm2) obtained from the buccal wall of the cavity. The samples were stored in distilled water at 37°C for 24 h prior to IlTBS Testing. For each elastic layer, one additional group was accomplished to measure the bond strengths on corresponding buccal flat surface by cutting away the rest of the cavity walls (C-factor = 0.22). The data were analyzed using one and two-way ANOV A, Tukey Test for multiple comparisons and Dunnett's Test, at a significance levei of 0.05. The characteristic strength (TBSO) in this study varied about 11.2-29.6 Mpa. Statistical significant differences were verified among the resin composites (p = 0.0079) and among the various elastic layers in both cavity bonding groups (p< 0.0001) and flat bonding groups (p = 0.0095). The Z250 resin composite showed the higher TBS means, with statistical differences of the Zl00. The SLirefil groups exhibited comparable TBS means to others two composites. In the cavity bonding groups, the TBS values for Z250, Z100 and Surefil were respectively: SB+SBMP (27, 22.9, 20.4)a, SB+PLF (19.8, 21.3, 18.5)ab, SB+FF (21.3, 19, 15.4)bC, SB-3e (17.9, 16.4, 14.2)bc, OS-1e (15.9, 14.2, 16)bc and SB-1e (17, 14.8, 11.2)C. The mean bond strengths obtained in eavity bonding group were significantly lower than those of the flat bonding group, exeept when the Z250 resin eomposite was associate with SB+SBMP, SB+PLF, SB+FF and SB(3e) and the Surefil resin eomposite was associate with SB+PLF. This association provides the best bond strengths in eavity, similar to the bonding on a flat eavity. The TBS means are dependent of the eomposite and the various formed elastie layer. The use of a low-viseosity eomposite or multiple applieations of adhesive as intermediate layer ean provide a stress absorbing layer, whereby inereasing the resin/dentin bond strength in box-shaped eavities / Doutorado / Dentística / Doutor em Clínica Odontológica
123

Influencia da escovação sobre a dureza knoop e rugosidade de superficie de materiais restauradores esteticos

Carvalho, Adriana Silva de 10 December 1998 (has links)
Orientadores: Lourenço Correr Sobrinho, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-24T11:42:24Z (GMT). No. of bitstreams: 1 Carvalho_AdrianaSilvade_D.pdf: 3871249 bytes, checksum: 32288d9fbf44f80ddebb2d160bd766b8 (MD5) Previous issue date: 1998 / Resumo: O propósito deste estudo foi avaliar a influência da escovação mecânica sobre a dureza Knoop e rugosidade de superfície antes e após a escovação, dos materiais restauradores estéticos, conhecidos comercialmente como: SR-Isosit, Artglass e Porcelana Duceram, submetidos ou não ao polimento. Oito corpos-de-prova com formato cônico (7 mm de diâmetro na região de superfície e 6 mm de diâmetro na superfície oposta por 2,5 mm de espessura) foram confeccionados para cada tipo de material, e armazenados em temperatura e umidade ambiente (23 '+ OU ¿' 1 °C, 50% '+ OU ¿' 5 U.R.) por 24 horas. Após esse período, quatro corpos-de-prova receberam tratamento de acabamento e polimento, e quatro não (controle). Em seguida, os corpos-de prova foram levados ao rugosímetro (Prazis - Rug 03 - Argentina), para determinarmos a rugosidade inicial da superfície. Foram feitas três leituras em cada corpo-de-prova, totalizando 72 leituras. Após a verificação da rugosidade inicial, os corpos-de-prova foram submetidos ao ensaio de dureza Knoop inicial no aparelho HMV - 2000 (Shimadzu), calibrado com carga de 50 gramas, atuando por 30 segundos. Foram efetuadas 3 leituras em cada corpo de-prova. Posteriormente, os corpos-de-prova foram levados a uma máquina de escovação Equilabor, submetidos à movimentos lineares de escovação com escovas dentais Oral-B 30 e creme dental Sorriso (Kolynos do Brasil), totalizando 30.000 ciclos de escovação. Em seguida, foram novamente submetidos à leitura da rugosidade superficial produzida pela escovação e ao teste de dureza Knoop. Os resultados foram submetidos à análise de variância e ao teste de Tukey. O SR-Isosit apresentou valores de rugosidade superiores em relação aos ART e DUG (p<0,05), antes da escovação e sem polimento; enquanto o ART foi o mais rugoso após a escovação. O polimento proporcionou aumento na rugosidade superficial dos 3 materiais, antes a após a escovação, sendo que o Duceram (DUG) apresentou maior rugosidade. De uma maneira geral, os valores de rugosidade foram maiores quando o polimento foi feito antes da escovação, e após a escovação nos corpos-de prova não polidos. A porcelana DUC com e sem polimento antes da escovação apresentou os maiores valores de dureza Knoop em relação ao SRI e ART, os quais não diferiram entre si (p>O,05). Resultados semelhantes foram obtidos após a escovação. A porcelana (DUC) com polimento antes da escovação apresentou valores estatisticamente superiores (p<O,05) em relação aos valores obtidos após a escovação. Nenhuma diferença estatística (p>O,05) foi observada para os materiais SRI e ART. Para as amostras não submetidas ao polimento, nenhuma diferença (p>O,05) foi encontrada entre os tratamentos antes e após a escovação. Independente do material restaurador, o polimento proporcionou valores de dureza Knoop estatisticamente superiores para os três materiais antes e após a escovação / Abstract: The purpose of this study was to investigate the influence of mechanic brushing on Knoop hardness and surface roughness of SR-Isosit, Artglass and Duceram. Eight specimens with 7mm in diameter and 2.Smm thickness were prepared for each material and stored in a controlled environment (23 '+ OU ¿' 1°C; 50 '+ OU ¿' RH). Four specimens of each material received fíníshing and polishing treatment and four without treatment (control). For each samples the roughness and Knoop hardness were verified, using Prazis-Rug 03 - Argentina and HMV - 2000 ~himadzu (50 g, during 30 s each tests) apparatus respectively. Afier the specimens were submited to 30,000 cycling in a Equilabor brushing machine, using a toothbrush (Oral-B 30) and toothpast (Kolynos). Afierwards, the Knoop hardness and roughness were verified. The results were statistically analysed using a Tukey's test. The results indicated that (1) ¿ The roughness for SR-Isosit was significantly higher than Artglass and Duceram (p<0,05) before tooth brushing without polishing, while the Artglass was more roughness afier toothbrushing; (2) - The roughness afier polishing of each material before or afier toothbrushing were significantly higher than without polishing (control) (p<0,05); (3) - The Knoop hardness for Duceram with and wíthout políshing before or afier toothbrushing was significantly stronger than SR-Isosit and Artglass (p<0,05). No difference was found between SR-Isosit and Artglass / Doutorado / Materiais Dentarios / Doutor em Ciências
124

Determinação da rugosidade, força de deslizamento, coeficiente e resistencia de atrito entre braquetes e fios ortodonticos

Secco, Angelo Stefano 25 July 2018 (has links)
Orientador: Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T18:54:50Z (GMT). No. of bitstreams: 1 Secco_AngeloStefano_D.pdf: 5008331 bytes, checksum: edd9d70da37852140146362ca5b4758a (MD5) Previous issue date: 1999 / Resumo: Considerando a falta de informações a respeito da força de deslizamento e 1 de atrito quando utiliza-se a mecânica de deslize com materiais de fabricação nacional, este trabalho foi desenvolvido com o objetivo de determinar a magnitude da força necessária para que ocorra o deslizamento do bráquete no fio, assim como determinar o valor da força de atrito, o percentual da força despendida com o atrito, o efeito da espessura dos fios na força de atrito, o coeficiente de atrito entre bráquetes e os fios, além de comparar a rugosidade do fio nacional com a do fio importado. Foi utilizado um sistema que simula a situação na qual os dentes inclinam suavemente até criar pontos de contato duplos e opostos entre a canaleta dos bráquetes e o fio. O sistema gerou uma tensão de 100g no centro de resistência a 10 mm da canaleta do bráquete, agindo no sentido oposto ao da força aplicada para mover o dente. Foram avaliadas 3 marcas de fios e bráquetes: duas nacionais - Tecnident e Morelli e uma importada - Dentaurum, Alemanha. Foram utilizados bráquetes metálicos de canaleta 0,022" e três : espessuras de fios 0,016x 0,022", 0,018x0,025" e o 0,021x0,025". Os testes foram realizados em uma máquina de ensaios Instron a uma velocidade de : 5mm/min. Os resultados apresentaram as seguintes médias de força de deslizamento para os fios Tecnident (198g) e Morefli (199g); estes resultados foram maiores e diferiram ao nível de significância de 5% da força requerida para deslizar o bráquete no fio importado Dentaurum, (178g). A variação da espessura dos arcos não interferiu significativamente na força de deslizamento assim como na força de atrito. A força de atrito desenvolvida pelos materiais nacionais Tecnident (98g) e Morelli (99g) foi maior e diferiu ao nível de significância de 5% da desenvolvida para o importado Dentaurum (78g). O percentual médio de força dissipada pelo atrito entre o bráquete e o fio ortodôntico durante o deslizamento foi de aproximadamente 49,8% para o conjunto bráquetes/arcos nacionais e 44,0% para o importado. Essa diferença foi significativa ao nível de 5% de significância. O material da marca Tecnident apresentou o maior coeficiente de atrito (0,164534); no entanto, a Morelli (0,150190) não diferiu estatisticamente da Dentaurum, que apresentou o menor coeficiente de atrito (0,147943). A rugosidade média dos fios da Tecnident foi da ordem de 0,15 um, aproximadamente 50% mais rugosos que os valores encontrados para os fios da marca Morelli 0,07u.m e da Dentaurum 0,07 j,m . Os fabricantes nacionais de bráquetes e fios ortodônticos devem rever o processo da fabricação de seus produtos para melhorar suas propriedades e características / Abstract: An appliance was constructed to simulate tooth movement in a previously aligned arch relative to bracket slot Nevertheless, when tooth was translated to siding mechanics, the crown was moved before the root, resulting in bracket tapping and angulation relative to the arch wire, making the arch contact the bracket two opposite points, creating friction. Regarding the lack of information about this situation using national manufactured materials, we developed the present study in order to determine: the force magnitude to occur bracket sliding, the frictional force \falues, the percentage of force dispersed by the friction, the effect of archwire \j/idth in frictional force, the coefficient of friction between brackets/archwires; and p compare the national and international archwires roughness. The system used simulated the clinical situation which slightly teeth tipping created two opposite joints contact between bracket slot and archwire. The system created a tension of 100g in the center of resistance from 10 mm to the bracket slot, acting in opposite side of the applied force to move the tooth. Three different arches and brackets ijjnds were evaluated, two national (Tecnident and Morelli) and one international (JDentaurum, from Germany). Stainless steel brackets slot of 0.022" and three archwires width were used (0.016 x 0.022", 0.018 x 0.025" and 0.021 x 0.025"). The tests were realized with an Instron testing machine moving at a speed of 5 ijnm/min. Results showed that mean force required to conduct brackets along national arches - Tecnident (198g) and Morelli (199g) - were higher and had Significant difference at 5% level to international one - Dentaurum (178g). The change in arches width did not interfere significantly both in sliding and frictional force. Frictional force developed by national materials Tecnident (98g) and Morelli (99g), were higher than international Dentaurum (78g), which was different statistically at 5% level. The mean force dispersed by friction between bracket and archwire during sliding was 49,8% to the national bracket/arch combination approximately, and 44% to the international one. This difference was significant at 5% level. National material Tecnident presented the highest frictional coefficient (0.164534). National material Morelli (0.150190) was not significant statistically relative to Dentaurum (0.1479430), which showed the lowest frictional coefficient. The average roughness of Tecnident arch was 0.15 urn approximately 50% more roughness than values found to Morelli (0.7 urn) and Dentaurum (0.7 jj.m) arches, in which there were not significant differences statistically (p<0.05) between roughness values / Doutorado / Doutor em Materiais Dentários
125

Influencia do sitio de adesão e do tempo de armazenamento em agua na resistencia a tração de sistemas adesivos aplicados sob o efeito da pressão pulpar simulada

Pereira, Gisele Damiana da Silveira 24 August 2001 (has links)
Orientadores : Luis Alexandre Maffei Sartini Paulillo, Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-31T18:53:06Z (GMT). No. of bitstreams: 1 Pereira_GiseleDamianadaSilveira_D.pdf: 6948071 bytes, checksum: 7be10a0df1892eef9f86e15690afde49 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar a influência do sítio de adesão, dentina acima da região dos cornos pulpares e dentina abaixo da fóssula oclusal central, e do tempo de armazenamento em água na resistência à tração de três sistemas adesivos aplicados sob condições de pressão pulpar simulada. Vinte e sete fragmentos dentais foram obtidos de terceiros molares hígidos e recém-extraídos após a remoção do esmalte oclusal e da porção radicular. Posteriormente ao desgaste da superfície em dentina com lixas de SiC 600, os dentes foram divididos em 18 grupos e acoplados ao aparelho que simulou a pressão pulpar positiva de 25 mmHg. Os sistemas Clearfil Mega Bond (MB), Prime & Bond Nf (Nf) e Prime & Bond 2.1 (PB) foram aplicados de acordo com as recomendações dos fabricantes, e as superfícies tratadas foram restauradas com o compósito TPH Spectrum. Após o armazenamento em água destilada por 7(A), 60 (B) ou 180 (C) dias, os conjuntos fragmentos dentais/resina composta foram seccionados paralelamente ao seu longo eixo nos sentidos mésio distal e vestíbulo-lingual para a obtenção de 407 espécimes com aproximadamente lmm2 de área, das regiões de dentina central (DC) e acima dos cornos pulpares (DP), que foram submetidos ao teste de tração realizado a uma velocidade de 0,5 mm/min. O teste LSD- Diferença Mínima Significante de Fisher revelou haver diferenças estatísticas significativas entre os grupos (p<0,05). Os valores em MPa foram: PBDCA 38,86a, PBDCB- 38,48ab, PBDCC- 36,81 b, MBDCA- 34,42c, MBDPA- 33,4900, NrDCA- 32,26OOe, NrDPA- 31,04def, NrDCB- 30, 74ef, PBDPA- 30,04f9, PBDPB 29,019, NfDPB- 28,089, PBDPC- 21,67h, NrDCC- 21,18 / Abstract: This laboratory study was conducted in order to evaluate the influence of dentin adhesion sites and storage time on the microtensile bond strength of three adhesive systems applied under simulated pulpal pressure. Twenty-seven dental discs were obtained from sound extracted human third molars after the removal of oclusal enamel and the root portion. Dentin surfaces were ground with 600 grit SiC abrasive papers to produce a standardized smear layer thickness. T eeth were randomly divided into eighteen groups and fixed in a device which simulated a 25 mmHg pulpal pressure. Clearfil Mega Bond (MB), Prime & Bond NT (NT) and Prime & Bond 2.1 (PB) adhesive systems were applied following their manufacturers' instructions and the bonded surfaces were restored incrementally with 10 mm high composite crowns (TPH Spectrum). After storage in distilled water for 7 (A), 60 (B) or 180 (C) days, the teeth were serially sectioned parallel to their long axis in a mesio-distal and buccal-lingual directions to obtain .:t1mm2 bonded sticks from the central area of oclusal dentin (CD) and from the area above the pulpal homs (PD). Afterwards, each stick was individually submitted to the tensile test performed at a 0.5 mm/min crosshead speed. Fisher's Least Significant Difference test showed statistically significant differences among groups (p< 0.05). Values in MPa were: PBCDA- 38.86 a, PBCDB- 38.48ab, PBCDC 36.81b, MBCDA- 34.42c, MBPDA- 33.4900, NTCDA- 32.26cde, NTPDA- 31.04def, NTCDB- 30.74ef, PBPDA- 30.04fg, PBPDB- 29.0fg, NTPDB- 28.08g, PBPDC- 21.67 / Doutorado / Dentística / Doutor em Clínica Odontológica
126

Efeito do tempo na qualidade do condicionamento promovido pelos acidos fosforico e maleico em esmalte e dentina

Goes, Mario Fernando de, 1954- 24 July 2018 (has links)
Tese (livre-docencia) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-24T00:13:29Z (GMT). No. of bitstreams: 1 Goes_MarioFernandode_LD.pdf: 4259228 bytes, checksum: 595792dd13046cebba749d22e596c3b4 (MD5) Previous issue date: 1994 / Resumo: O objetivo deste estudo foi avaliar a qualidade do condicionamento promovido pelos ácidos fosfórico a 35%, fosfórico a 10% e maleico a 10% sobre a superfície do esmalte e dentina, após 15 e 60 segundos de tratamento, usando microscópio eletrônico de verredura e ensaios de resistência ao cisalhamento. Foram utilizados 78 dentes humanos constituídos por grupos caninos, pré-molares e molares, cujas raízes foram seccionadas e as coroas dentárias remanescentes incluídas com resina acrílica ativada quimicamente em tubos de PVC. A face vestibular foi desgastada com lixas d'água de granulação número 180 e 400, respectivamente, até conseguir uma área plana de 5mm de diâmetro na superfície do esmalte ou dentina. Após a preparação das superfícies dentárias, uma fita adesiva circular com um orifício central de 4mm de diâmetro foi aderida sobre a superfície do esmalte ou dentina, com a finalidade de delimitar a área onde se efetuaria a união adesivo-material restaurador. A área delimitada para a união (esmalte ou dentina) foi tratada com um dos seguintes agentes: ácido fosfórico a 35% (3M); ácido fosfórico a 10% (Bisco); e, ácido maléico a 10% (3M), por 15 e 60 segundos, respectivamente. Em seguida, as amostras foram lavadas, secas e aplicados o Scotchbond Primer e Adesivo, conforme a indicação do fabricante, e o compósito restaurador Z 100 (3M) foi inserido através de uma matriz de aço inoxidável (4mm de diâmetro por 5 mm de altura), em três camadas, cada uma polimerizada durante 40 segundos. Os corpos de prova foram armazenados a 37°C e 100% de umidade relativa durante 24 horas e submetidos ao ensaio de resistência ao cisalhamento em máquina de ensaio universal Otto Wolpert Werke, a uma velocidade de 6mm/min.. As superfícies do esmalte ou dentina condicionadas dos dentes restantes foram revestidas com ouro-paládio sob alto vácuo para observação em microscopia eletrônica de varredura. As fotomicrografías da superfície do esmalte mostraram que os ácidos fosfóricos a 35% e a 10% produziram padrões morfológicos semelhantes após 15 ou 60 segundos de condicionamento, enquanto que o tratamento com ácido maléico a 10%, por 15 segundos, produziu um aspecto topográfico superficial significativamente diferente. No entanto, após 60 segundos de condicionamento, o padrão morfológico tornou-se semelhante àquele produzido pelos ácidos fosfóricos a 35% e a 10%. O condicionamento da dentina, por 15 ou 60 segundos, com ácido fosfórico a 35% e ácido fosfórico a 10%, removeu completamente a camada de "smear layer" e proporcionou a abertura dos tubulos dentinários. No entanto a ação do ácido maléico a 10%, durante 15 segundos, removeu a camada de "smear layer", mas deixou a abertura dos túbulos denrinários parcialmente fechada, enquanto que, após 60 segundos de condicionamento a camada de "smear tayer" foi completamente removida e os túbulos dentinários abertos. Os valores médios de resistência ao císalhamento (MPa) na superfície do esmalte após 15 e 60 segundos de condicionamento foram 10,64 e 7,58 para o ácido fosfórico a 35%; 12,27 e 10,91 para o ácido fosfórico a 10%; e, 10,16 e 14,22 para o ácido maléico a 10%, respectivamente. Na superfície da dentina os valores médios foram 4,24 e 4,18 para o ácido fosfórico a 35%; 4,84 e 4,79 para o ácido fosfórico a 10%; e, 6,00 e 4,75 para o ácido maléico a 10%, respectivamente. A análise de variância e o teste de Tukey mostraram que a média de resistência ao císalhamento na superfície do esmalte condicionado com ácido fosfórico a 10%, durante 15 segundos, foi significativamente superior (P<0,05) do que o ácido fosfórico a 35% e ácido maléico a 10%. Para o esmalte condicionado com ácido maléico, durante 60 segundos, os valores médios foram estatisticamente superiores (P<0,05), em relação aos valores produzidos na superfície condicionada com os ácidos fosfóricos a 10% e a 35% que são estatisticamente diferentes entre si (P<0,05), em relação aos valores obtidos após 60 segundos de tratamento. Entretanto, o condicionamento efetuado com ácido maléico a 10%, durante 60 segundos, produziu valores estatisticamente superiores (P<0,05), em relação ao tempo de 15 segundos de tratamento. A análise de variância e o teste de Tukey mostraram que os valores médios obtidos na superfície da dentina condicionada com ácido maléico a 10%, durante 15 segundos, foram significantemente superiores (P<0,05) em relação ao ácido fosfórico a 35%. Após o tratamento por 60 segundos não houve diferença estatisticamente significante entre os diferentes tratamentos. Entretanto, a média de resistência ao cisalhamento sobre a superfície da dentina produzida pelo condicionamento com ácido maléico a 10% durante 15 segundos, foi estatisticamente superior (P<0,05) em relação ao tempo de 60 segundos. Os valores obtidos na superfície da dentina condicionada pelos ácidos fosfóricos a 10% e 35% não apresentaram diferença estatisticamente significativa (P<0,05) entre os tempos de 15 e 60 segundos / Abstract: The purpose of this study was to evaluate the effects on enamel and dentin surfaces etched with 35% and 10% phosphoric acid gel, 10% maleic acid gel for 15 and 60 seconds using scanning electron microscopy and shear bond strenght tests. Seventy-eight extracted human permanent molar, premolar and canine teeth were mounted in phenolic rings with cold-cure acrylic resin and the facial surfaces were ground wet in a polishing block on a polishing machine on 180 - followed by 400 - grit silicon carbide paper. Adhesive tape with a circular hole, 4mm in diameter, was placed on the ground enamel and dentin surfaces to delineate the bonding areas which were treated with 35% phosphoric acid gel (3M), 10% phosphoric acid gel (Bisco) and 10% maleic acid gel (3M) for 15 and 60 seconds, respectively. After rinsing, Scotchbond Primer and Adhesive were applied as directed by the manufacturer, and'composite (restorative Z 100, 3M) was applied in a split metal mold in three increments. Each increment was compressed firmly and exposed to visible ligth for 40 seconds. The specimens were stored in distilled water at 37°C for 24 hours and the shear bond strengths were determined by using an Otto Wolpert Werke universal testing machine operated at a cross-head speed of 6 mm/min.. Representative specimens from each group were examined by scanning electron microscopy. Electronmicrographs of enamel surfaces showed similar etching patterns with 35% and 10% phosphoric acid applied for either 15 or 60 seconds, but the surface topography was significantly different when etched with 10% maleic acid for 15 seconds. The surface morphology of enamel etched with phosphoric acid for 60 seconds was similar to enamel surfaces etched with 10% maleic acid. The dentin surface treated for 15 or 60 seconds with 35% and 10% phosphoric acid removed the smear layer and opened the dentinal tubules in a similar manner. However, dentin etched with 10% maleic acid for 15 seconds revealed an absence of the smear layer but the dentinal tubules were partly occluded. Dentin treated with 10% maleic acid for 60 seconds removed the smear layer and exposed the dentinal tubules. Mean enamel bond strengths (MPa) after treatment for 15 and 60 seconds were 10.64 and 7.58 for 35% phosphoric acid, 12.27 and 10.91 for 10% phosphoric acid ; 10.16 and 14.22 for 10% maleic acid, respectively. The mean bond strengths to dentin were 4.24 and 4.8 for 35% phosphoric acid; 4.84 and 4.79 for 10% phosphoric acid ; 6.00 and 4.75 for 10% maleic acid, respectively. ANOVA and Tukey's test showed that the mean enamel bond strength to surfaces etched with 10% phosphoric acid for 15 seconds were significantly higher (P<0.05) than to surfaces etched with 35% phosphoric acid and 10% maleic acid for 15 seconds. The bond strength to enamel with phosforic acid etched for 60 seconds was significantly lower than to surfaces etched with 10% maleic acid (P<0.05). The bond strengths to enamel etched with 10% and 35% phosphoric acid for 60 seconds were statistically different (P<0.05) while treatment with 10% and 35% phosphoric acid for 15 seconds resulted in significatly higher bond strength when etched for 60 seconds (P<0.05). The bond strength to surfaces etched with 10% maleic acid for 60 seconds was significantly higher (P<0.05) than when etched for 15 seconds. The mean dentin bond strengths at 10% maleic acid after etched for 15 seconds was significantly higher (P<0.05) than the 35% phosphoric acid for 60 seconds. After treatment for 60 seconds no difference (P>0.05) was found for shear bond strength. However, the average value of shear bond strength for dentin in the etched group with 10% maleic acid, for 15 seconds, was significantly higher (P<0.05) than the etched group for 60 seconds. No statistical difference was found for 10% and 35% phosphoric acid between 15 and 60 seconds of"etching / Tese (livre-docencia) - Univer / Materiais Dentarios / Livre docente em Odontologia
127

Influencia do ionomero de vidro da resina composta na sustentação do esmalte e seu efeito na rigidez, deflexão e resistencia a fratura das cuspides dos dentes restaurados

Secco, Angelo Stefano 30 August 1995 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T15:58:57Z (GMT). No. of bitstreams: 1 Secco_AngeloStefano_M.pdf: 3238589 bytes, checksum: afa95602c2fed0a7ae9a1b3cfbe97556 (MD5) Previous issue date: 1995 / Resumo: O objetivo deste trabalho foi analisar a influência do cimento de ionômero de vidro e da resina composta na sustentação do esmalte sem apoio de dentina, assim como, os efeitos na rigidez, deflexão e resistência à fratura das cúspides dos dentes restaurados. Foram utilizados 42 pré-molares superiores recentemente extraídos, mantidos hidratados e divididos em 6 grupos de 7 dentes: 1 - Dente hígido; 2 - Classe II MO; 3 - Classe II mais remoção da dentina de suporte do esmalte oclusal; 4 - Idem grupo 3, com esmalte oclusal suportado com ionômero de vidro Ketac Bond, (ESPE); 5 - Idem grupo 3, com esmalte oclusal suportado com Vitremer (3M); e, 6 - Idem grupo 3, com esmalte oclusal suportado com resina Z100 (3M). Em todos os grupos antes dos tratamentsos iniciarem e após cada tratamento foram realizadas leituras de extensiometria com os extensômetros colados na superfície vestibular e língual de cada dente, aplicando-se uma carga de 12kg na oclusal dos dentes através da máquina Instron regulada à uma velocidade de 0,05mm/s. Os dados obtidos foram utilizados para os cálculos da variação da rigidez e deflexão das cúspides após cada tratamento. Após a realização desse teste, os dentes foram submetidos ao ensaio de resistência à fratura. Os resultados foram submetidos à análise de variância e ao teste de Tukey. Os resultados indicaram que a resina composta suportando esmalte, recuperou 65% da rigidez das cúspides, perdida com o preparo cavitário e diminuiu a deflexão em 75%, não diferindo do dente hígido (p<0,05); o ionômero fotopolimerizável recuperou 25% da rigidez e diminuiu em 42% a deflexão, não atingindo estatisticamente os valores do dente hígido, porém, foi melhor que o preparo classe II com remoção de dentina no dente não restaurado (p<0,05). O ionômero convencional apresentou o pior desempenho: recuperou apenas 16% da rigidez e dirninuiu em 22% a deflexão, porém, não diferiu do preparo classe II com remoção de dentina e não restaurado. Nenhuma condição restauradora recuperou os valores de resistência à fratura das cúspides do dente hígido (p>0,01). No entanto, todos os materiais suportando esmalte aumentaram a resistência à fratura do esmalte oclusal suportado artificialmente. E a resina composta demonstrou, dentre todos eles, ser o material mais mdicado para suportar esmalte, em função da recuperação da rigidez, deflexão e aumento da resistência à fratura do esmalte suportado / Abstract: The purpose of this study was to evaluate the influence of glass ionomer and composite resin to conserve unsupported enamel, as well as to evaluate the effect of cuspal stiffness, flexure, and strength of restored teeth against fracture. Forty-two freshly extracted maxillary premolars were selected for using in this study. Cuspal stiffness and flexure were assessed using a strain gauge bonded to buccal and lingual surfaces. Cuspal stiffness and flexure were evaluated in sequentially performed procedures: 1. unaltered tooth, 2. MO cavity preparation, 3. removal dentin of supporting occlusal enamel in class II preparation, 4. glass ionomer Ketac Bond (ESPE) and Vitremer (3M) and composite resin Z100 (3M) supporting occlusal enamel. Each tooth was loaded with a 12 kg force, at a speed of 0,05 rnm/rnin in Instron test machine. After nondestructive test, the teeth were subjected to fracture resistance test. The data were analyzed using a one way ANOVA, and Tuckey's test. Results indicated that composite resin supporting enamel recovered 65% of the lost cuspal stiffness with the cavity preparation and the flexure was decreased in 75%, similarly to the unaltered tooth (p<0.05); the light-cured glass ionomer recovered 25% of lost cuspal stiffness and flexure was diminished in 42%, it was significantly lower than unaltered tooth, better than the prepared and unrestored one (p<0.05); the auto-cured glass ionomer recovered 16% of the lost cuspal stiffness and the flexure was decreased in 22%. The difference was not significant when compared to the unrestored teeth. This study concluded that all the restorative materials supporting enamel increased the fracture resistance of artificial supported enamel and composite resin was the best restorative material to support the enamel concerning to cuspal stiffness and flexure / Mestrado / Materiais Dentarios / Mestre em Ciências
128

Resistencia a tração de coroas metalicas fundidas

Trevisan, Antonio Carlos 09 January 1987 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-17T14:36:27Z (GMT). No. of bitstreams: 1 Trevisan_AntonioCarlos_M.pdf: 654897 bytes, checksum: d89340c99a0b7985018dde70b042ff95 (MD5) Previous issue date: 1986 / Resumo: o objetivo deste trabalho foi verificar a influência do acondicionamento da dentina com soluções de fluoreto de sódio 2% e hidróxido de cálcio 10% sobre a resistência à tração de coroas metálicas fixadas com cimentos de fosfato de zinco e policarboxilato de zinco. Foram utilizados dentes humanos recém-extraídos, armazenados em soro fisiológico. Os dentes foram fixados pela porção radicular com resina crílica ativada quimicamente em tubos de P.V.C. medindo 2 cm de diâmetro por 5 cm de altura ...Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: In the course of this investigation a procedure has been envolved to verify the influence of conditianing surface of dentin with a sodium fluoride solution, 2% rate, anda calcium hydroxide solution, 10% rate, over a traction resistance of metalic crowns, fixed with zinc phosphate and zinc polycarboxylate cement. Human being teeth, just removed, were used in this evaluation and preserved in fisiological serum. The teeth were fixed at the radicular portion with acrilic resin chemically activated in PVC tubes with 2 cms de diemeterper 5 cms of heigth. (1 inch 2.54 cms) ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Materiais Dentarios / Mestre em Odontologia
129

Silicato para modelos : (estudo de algumas de suas propriedades fisicas)

Gonçalves, Nivaldo, 1933- 18 July 2018 (has links)
Orientador: Luiz Antonio Ruhnke / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-18T00:52:41Z (GMT). No. of bitstreams: 1 Goncalves_Nivaldo_D.pdf: 1467759 bytes, checksum: 91d9451e93d31ccd4a6f1f1707dc9718 (MD5) Previous issue date: 1967 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Doutor em Ciências
130

Cimento de silicato : contribuição ao estudo de uma de suas propriedades opticas : reflexão

Stolf, Wolney Luiz, 1937- 18 July 2018 (has links)
Orientador: Luiz Antonio Ruhnke / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-18T00:51:15Z (GMT). No. of bitstreams: 1 Stolf_WolneyLuiz_D.pdf: 4873821 bytes, checksum: 42f912ddfb66772fb04139e3d2c02052 (MD5) Previous issue date: 1967 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Materiais Dentarios / Doutor em Ciências

Page generated in 0.0232 seconds