• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Nanocompósito de alumina com inclusão nonométricas de zircônia para infraestruturas de próteses odontológicas livres de metal: avaliação de prosperidades mecânicas e análise microestrutural. -

Pierri, Juliano de [UNESP] 29 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-29Bitstream added on 2014-06-13T19:05:07Z : No. of bitstreams: 1 pierri_j_dr_arafo.pdf: 3628153 bytes, checksum: fa1a39047c990b824665426ff4169b19 (MD5) / As próteses cerâmicas sem metal têm sido cada vez mais utilizadas em função das vantagens apresentadas, como biocompatibilidade, resistência à compressão, estabilidade de cor, radiopacidade e baixa condutibilidade térmica e elétrica. O potencial desses materiais em mimetizar os tecidos dentais também tem contribuído para aumentar sua indicação, atendendo a crescente exigência estética dos pacientes. Apesar dessas características favoráveis, percentuais consideráveis de insucesso clínico têm sido observados, demonstrando que as propriedades mecânicas dos materiais utilizados ainda precisam ser melhoradas. Uma alternativa ainda pouco explorada na odontologia é a utilização de inclusões nanométricas como reforço em matriz também cerâmica, obtendo-se os nanocompósitos cerâmicos. Assim, o objetivo do presente estudo foi avaliar as propriedades de dureza, tenacidade e limite de resistência à fadiga flexural de nanocompósito denso de matriz de alumina com inclusões nanométricas de zircônia, visando sua aplicação em infraestruturas de próteses odontológicas livres de metal. As amostras foram produzidas seguindo metodologia estabelecida em estudos anteriores, que consiste nas seguintes etapas: 1) mistura das matérias primas por meio de desaglomeração da alumina pura e da ZrO2 nanométrica em moinho de bolas convencional; 2) adição da suspensão contendo as partículas nanométricas com a alumina por gotejamento contínuo da suspensão alcóolica de ZrO2 e mistura em moinho de bolas convencional; 3) secagem dos pós no interior do moinho de bolas, sob agitação, em temperatura próxima da ambiente, com auxílio de fluxo de ar perpendicular à abertura do frasco de moagem; 4) preparo das amostras com a mistura obtida, aplicando-se prensagem uniaxial (50 MPa), seguida de prensagem isostática... / Metal free prosthesis became popular because of the advantages presented by the ceramic materials, such as biocompatibility, compressive strength, color stability, radiopacity and low thermal and electrical conductivity. The potential of these materials to mimic the dental tissues and the patient’s demand for aesthetic treatments have also contributed to their increased popularity. Despite these favorable characteristics, considerable percentage of clinical failure has been observed, demonstrating that their mechanical properties still need improvements. An alternative yet little explored in dentistry is the use of nanometric inclusions as reinforcement, resulting in ceramic nanocomposites. Thus, the objective of this study was to evaluate the hardness, toughness and flexural fatigue properties of a nanocomposite comprised of alumina matrix reinforced with nano-inclusions of zirconia, expected to be used as infrastructure for metal-free prosthesis. The samples were produced following the method established in a previous study, which consists of the following steps: 1) mixture of pure alumina and nano-ZrO2 powders in conventional ball mill, 2) addition of the suspension containing the particles with nanometric alumina suspension by continuous drip of ZrO2 and mixing in conventional ball mill, 3) drying the powder inside the ball mill, stirred at ambient temperature, with the aid of air flow perpendicular to the opening of the bottle crushing; 4) sample preparation applying a uniaxial (50 MPa), followed by isostatic pressing (200 MPa). The samples were made in prismatic form (25 X 5 X 2 mm) for flexural fatigue test (n = 30) and disc-shaped (chips) with 10 mm diameter and 5 mm thickness for testing toughness and hardness (n = 10); 5) removal of organic components added during the preparation of powders and... (Complete abstract click electronic access below)
82

Avaliação da retençao de coroas de Ytrio-zircônia cimentadas à diferentes substratos, com quatro agentes cimentantes, após termociclagem

Amaral, Regina [UNESP] 02 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-02Bitstream added on 2014-06-13T19:24:15Z : No. of bitstreams: 1 amaral_r_dr_sjc.pdf: 474843 bytes, checksum: ec47413ee9365a7ca21114ff7253d659 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho teve a finalidade de avaliar o efeito do tipo de substrato coronário (dentina e resina composta) na retenção de coroas cerâmicas de zircônia estabilizada por óxido de ítrio e comparar a retenção em função de diferentes protocolos. Para tanto, 144 molares recém-extraídos foram embutidos em resina acrílica, perpendicular ao seu longo eixo e preparados para coroa total, 72 permaneceram com o preparo em dentina e os demais, a parte coronária preparada foi removida e reconstruída em resina composta + pinos de fibra com dimensões idênticas à dentina preparada. Os preparos foram moldados com silicona de adição e dos troqueis foram obtidos 144 copings em YTZP, os quais apresentaram uma configuração especial para o ensaio de tração. Para ambos substratos, foi utilizado como grupo controle (n=12) um cimento à base de fosfato de zinco (sem condicionamento do substrato e da cerâmica). Os outros cimentos utilizados foram: um cimento à base de ionômero de vidro, um cimento resinoso da geração auto-condicionate (ambos sem condicionamento do substrato e da cerâmica) e um cimento Dual contendo monômeros fosfatados (MDP). Neste ultimo grupo, os remanescentes (dentina ou resina) foram condicionados com o adesivo correspondente do sistema e a cerâmica foi submetida a 3 tratamentos de superfície: álcool isopropílico, silicatização/silanização ou Vitrificação. Após 24h, todos os conjuntos foram submetidos a termocilagem (6000 ciclos) e incluídos em um dispositivo especial para o teste de tração em uma máquina de ensaio universal, para testar a retenção das infra-estruturas. Os modos de falha de todos os conjuntos foram analisados em estereomicroscópio e MEV para avaliar... / The aim of this study was to evaluate the effect of the crown substrate type (dentine and composite resin) in the retention of stabilized zirconia ceramic crowns by yttrium oxide (YTZP) and to compare the retention function of four types of cements, four treatments of the substrate surface and three treatments of the ceramic surface. For this purpose, 144 freshlyextracted molars were embedded in acrylic resin, perpendicular to the long axis and prepared for full crowns, 72 remained with the preparation in dentin and the other, the crown part was removed and reconstructed with composite resin + fiber pins with dimensions identical to the prepared dentin. The preparations were moulded with addition silicone and 144 YTZP copings were obtained, which presented a special setup for the tensile test. For the remainin, a phosphate-based cement zinc (unprimed substrate and ceramics) (n = 12) was used as the control group. The other used cements were: a glass-ionomer based cement, a resin cement from self-condicionating generation (unprimed substrate and ceramic) and a Dual cement containing phosphate monomer. In the latter groups, the remaining (dentin or resin) was conditioned with the adhesive system and the corresponding ceramic was subjected to three surface treatments: isopropyl alcohol, silica coating / silanization or Overglaze. After 24 hours, all sets were submitted to thermocycling (6000 cycles) and included in a special device for the tensile test in a universal testing machine to test the retention of the infrastructure. The failure modes of all sets were analyzed under a stereomicroscope and SEM to evaluate possible causes of failure. Data was analyzed statistically. The results showed that in dentin, the glass-ionomer... (Complete abstract click electronic access below)
83

Propriedades físico-químicas e mecânicas, potencial bioativo e caracterização da interface dentina-cimento de cimentos endodônticos experimentais à base de cimento Portland associados à radiopacificadores micro e nanoparticulados / Physicochemical and mechanical properties, bioactivity potential and characterization of the dentin-sealer interface of experimental root sealers based on portland cement with micro and nano particulate radiopacifiers

Viapiana, Raqueli [UNESP] 27 March 2014 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-27Bitstream added on 2015-04-09T12:47:35Z : No. of bitstreams: 1 000806823.pdf: 4815535 bytes, checksum: 8a928ad2b8e79998a887a16919911289 (MD5) Bitstreams deleted on 2015-04-23T11:39:26Z: 000806823.pdf,Bitstream added on 2015-04-23T11:39:58Z : No. of bitstreams: 1 000806823_20170327.pdf: 566845 bytes, checksum: 5251321f73ff5631ce7c00ef0c2f738e (MD5) Bitstreams deleted on 2017-03-31T12:19:27Z: 000806823_20170327.pdf,. Added 1 bitstream(s) on 2017-03-31T12:20:23Z : No. of bitstreams: 1 000806823.pdf: 4815535 bytes, checksum: 8a928ad2b8e79998a887a16919911289 (MD5) / O cimento Portland é constituído por silicato de cálcio e a associação com aditivos e veículos conferem características que podem viabilizar seu uso como cimento endodôntico. No entanto, o cimento Portland não apresenta radiopacidade própria, o que torna necessário a adição de um agente radiopacificador à mistura para ser utilizado como material dentário. O objetivo deste estudo foi avaliar as propriedades físico-químicas e mecânicas, o potencial bioativo e caracterizar a interface dentina-cimento de cimentos endodônticos experimentas à base de cimento Portland (ES) contendo nano ou micro partículas de óxido de zircônio ou óxido de nióbio. O tempo de presa, resistência à compressão, escoamento, espessura de filme, radiopacidade, solubilidade e estabilidade dimensional foram avaliadas de acordo com a norma ISO 6876:2012, enquanto que a liberação de fomaldeído foi avaliada por meio de cromatografia gasosa. A resistência de união dentinária foi avaliada por meio de teste push-out e tanto a caracterização da microestrutura dos cimento quanto a análise do potencial bioativo foram realizadas utilizando energia dispersiva de raios-x, difractometria e espectroscopia infravermelha. A interface dentina-cimento foi avaliada com relação à penetração de microesferas fluorescentes e examinada em microscopia confocal e microscopia eletrônica de varredura associada à escaneamento por energia dispersiva de raios-x linear. Os dados foram submetidos aos testes ANOVA e Tukey (p < 0,05). Com exceção da radiopacidade, os ES apresentaram propriedades físico-químicas de acordo com as especificações ISO 6876, adequada resistência de união à dentina, potencial bioativo e promoveram selamento coronário e interação química com a dentina. / Portland Cement is composed by calcium silicate and the association with additives or vehicles, may confer characteristics to enable the use of this cement as root canal sealer. However, Portland cement lacks in radiopacity which requires the addition of a radiopacifying agent to the mixture to be used as dental material. The purpose of this study was to assess the physicochemical and mechanical properties, the bioactivy potential and to characterize the dentin-sealers interfaces of Portland-based experimental root canal sealers (ES) containing nano or micro particles of zirconium oxide or niobium oxide. Setting time, compressive strength, flow ability, film thickness, radiopacity, solubility and dimensional stability were evaluated according to ISO 6876:2012 standards, whereas formaldehyde realease was investigated using gas-cromatography. Dentin bond strength was evaluated by push-out test and the sealer’s microestruture and bioactivity potential were perfomed using X-ray energy espectroscopy, X-ray diffractometry and infrared spectroscopy. Dentin-sealers interface was assessed with respect to fluorescent microspheres penetration and it was also examined using confocal microscope and scanning electron microscope coupled to X-ray energy dispersive line scans. Data were analyzed by ANOVA and Tukey post-hoc test (p < 0.05). With the exception of radiopacity, ES showed physicochemical properties according to ISO 6876:2012 specifications, adequate dentin bond strength, great bioactivity potential and promoted coronal sealing and chemical interaction with dentin.
84

Avaliação da atividade antimicrobiana de um reembasador resiliente combinado a um polímero antimicrobiano sobre a formação de bio-filme

Toda, Carina [UNESP] 14 November 2012 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-11-14Bitstream added on 2014-12-02T11:21:06Z : No. of bitstreams: 1 000792872.pdf: 571447 bytes, checksum: 3bae358d477e471a159de61135729477 (MD5) / Este estudo avaliou a atividade antimicrobiana de um reembasador resiliente Coe Soft® (RRCS) combinado ao polímero antimicrobiano poli (2 tert-butilaminoetil) metacrilato (PTBAEMA) sobre formação de biofilme de Staphyloccocus aureus, Streptococcus mutans e Candida albicans. Espécimes circulares (15mm x 3mm) do RRCS foram confeccionados (n=27), esterilizados, divididos em três grupos de acordo com as concentrações de PTBAEMA a 0% (controle), 10% e 25% e individualmente inoculados em tubos de falcon contendo 5mL de caldo RPMI para os fungos, TSB para S. aureus e BHI para S. mutans e mantidos em overnight a 37ºC em incubadora com agitação orbital a 75rpm, sendo o S. mutans em microaerofilia. Após a inoculação dos espécimes seguiu-se a formação e maturação do biofilme a 37ºC sob agitação orbital a 75rpm. Em seguida cada espécime foi transferido para tubos contendo PBS e diluições seriadas foram realizadas. Alíquotas dessas diluições foram semeadas em placas de Petri e incubadas a 37ºC por 48h. Os dados obtidos foram transformados em log (UFC+1)/mL, considerando-se α=0,05. Os resultados demonstraram que o grupo contendo 25% de PTBAEMA inibiu completamente a formação de biofilme de S. aureus e S. mutans. Uma redução significativa na contagem de S. aureus e S. mutans (Kruskal- Wallis e Dunn; p=0,001) para o grupo contendo 10% de PTBAEMA foi observada quando comparada aos valores encontrados nos respectivos grupos controle. Para C. albicans não foi encontrada diferença significante entre grupos contendo PTBAEMA e o grupo controle (ANOVA; p>0,05). Conclui-se que os RRCS contendo 10% e 25% de PTBAEMA inibiram a formação de biofilme de S. aureus e S. mutans. Entretanto não teve efeito significante na formação de biofilme de C. albicans. / This study evaluated the antimicrobial activity of the resilient reliner Coe Soft ® (RRCS) combined with antimicrobial polymer poly (2-tert butylaminoethyl) methacrylate (PTBAEMA) on Staphylococcus aureus, Streptococcus mutans and Candida albicans biofilm formation. RRCS circular specimens were prepared (n=27), sterilized, divided into three groups according to PTBAEMA concentrations of 0% (control), 10% and 25% and inoculated into individual falcon tubes containing 5 mL of RPMI broth for fungi, TSB for S. aureus and BHI for S. mutans and kept overnight at 37°C with orbital shaking incubator at 75rpm, and S. mutans in microaerophilic. The specimens’ inoculations were followed by biofilm formation and its maturation at 37°C under orbital shaking at 75rpm. After that, each sample was transferred to tubes containing PBS and serial dilutions were performed. Aliquots of these dilutions were plated in Petri dishes and incubated at 37°C for 48h. The data were transformed into log (CFU +1)/mL, considering α = 0.05. The results showed that the group containing 25% of PTBAEMA inhibited completely biofilm formation of S. aureus and S. mutans. A significant reduction in counts of S. aureus and S. mutans (Kruskal- Wallis and Dunn; p = 0.001) were found in group containing 10% of PTBAEMA when compared to the values in the corresponding control groups. C. albicans had no significant differences between groups containing PTBAEMA and the control group (ANOVA; p> 0.05). It is concluded that the RRCS containing 10% and 25% PTBAEMA inhibited the biofilmformation of S. aureus and S. mutans. However, no significant effect was found on C. albicans biofilm formation.
85

Alteração volumétrica por análise microtomográfica, solubilidade e capacidade seladora bacteriana de diferentes materiais retro-obturadores

Espir, Camila Galletti [UNESP] 20 March 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-20Bitstream added on 2015-03-03T12:07:26Z : No. of bitstreams: 1 000806506_20170320.pdf: 238529 bytes, checksum: d831096cd6a5be24730bc5a40cc1f0de (MD5) Bitstreams deleted on 2017-03-24T12:04:46Z: 000806506_20170320.pdf,. Added 1 bitstream(s) on 2017-03-24T12:05:38Z : No. of bitstreams: 1 000806506.pdf: 712508 bytes, checksum: 607fbbdefe1c6290ed1f232ba4f26a6b (MD5) / O objetivo deste estudo foi avaliar os materiais retro-obturadores MTA, Cimento Portland associado a 30% de óxido de zircônio (CP/ZrO2) e óxido de zinco e eugenol (OZE). Para análise microtomográfica da alteração volumétrica, cavidades retrógradas foram confeccionadas em dentina bovina e preenchidas com os materiais experimentais, sendo analisados pelo microtomógrafo Sky Scan 1176. A avaliação de solubilidade foi realizada de acordo com normas ISO 6876, por meio da diferença de massa inicial e após 7 dias de imersão em água destilada. A análise da capacidade seladora bacteriana foi realizada em dentes humanos extraídos. Cavidades retrógradas confeccionadas foram preenchidas de acordo com os materiais experimentais (n=12), além do controle positivo (n=8), sem preenchimento, e controle negativo (n=8), com impermeabilização em toda extensão. As amostras foram submetidas à infiltração utilizando cepas de Enteroccocus faecalis (ATCC 29212) em meio de cultura BHI, sendo observadas diariamente por 60 dias e a infiltração avaliada pela turbidez do meio. Os dados foram submetidos aos testes ANOVA e Tukey para solubilidade e alteração volumétrica, e Kruskall-Wallis e Dunn para capacidade seladora bacteriana. Na análise de solubilidade, não houve diferença estatística significante entre os grupos. A análise volumétrica demonstrou maior diminuição de volume para o OZE. Também foi observada maior infiltração bacteriana para o OZE. Conclui-se que MTA e CP/ZrO2 apresentam maior capacidade seladora bacteriana, que pode estar relacionada à menor alteração volumétrica. / The present study evaluated different properties of the root end sealers MTA, Portland cement with de 30% zirconium oxide (PC/ZrO2) and zinc oxide and eugenol (ZOE). To analyze the volumetric changes by computed microtomography, bovine teeth were used in which the prepared cavities in dentine were filled according to the materials and then analyzed by Sky Scan 1176. The solubility evaluation was in accordance with ISO 6876 standards, from the difference of the original mass and after 7 days of immersion in distilled water. For analysis of bacterial sealing capacity, extracted human teeth were used. Retrograde cavities were filled according with experimental materials (n=12), besides a positive control (n = 8), no fill, and a negative control (n = 8), with waterproofing to the fullest extent. The samples were subjected to infiltration using Enteroccocus faecalis strains (ATCC 29212) in BHI culture, and observed daily for 60 days and infiltration evaluated by turbidity of the medium. Data were submitted to ANOVA and Tukey tests for solubility and volumetric change, and Kruskall-Wallis and Dunn for bacterial infiltration. In the analysis of solubility, no statistically significant difference between groups. In the analysis of solubility, no statistically significant difference between groups. Volumetric analysis showed greater volumetric reduction for ZOE, as well as greater bacterial infiltration. It was concluded that MTA and CP/ZrO2 have larger bacterial sealing ability, which may be related to lower volumetric changes observed.
86

Avaliação das propriedades térmicas, químicas e mecânica relacionando dente bovino e dente humano

Dutra-Corrêa, Maristela [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T20:51:26Z : No. of bitstreams: 1 dutracorrea_m_me_sjc.pdf: 1252552 bytes, checksum: ac3c9bb37ab987d17287a6ac4f663595 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentes bovinos são amplamente utilizados substituindo dentes humanos em pesquisas in vitro, para avaliar o comportamento dos materiais odontológicos. Utilizaram-se sessenta dentes bovinos e sessenta humanos. Esmalte e dentina foram avaliados individualmente em Análises Termodiferencial, Termogravimétrica e Condutividade Térmica. A Dissolução foi avaliada em diferentes tempos e concentrações de ácido. No teste de Desidratação os fragmentos foram colocados em estufa por tempos diferentes. Na Incorporação de Água, após a retirada dos fragmentos da estufa, foram resfriados e depois imersos em água destilada. Verificou-se o quanto o tecido incorporou de água em sua massa. A Penetrabilidade de Corante foi avaliada pela Espectroscopia de Fluorescência. Para avaliar a Microdureza Vickers os dentes foram incluídos em resina de poliéster e polidos até expor esmalte ou dentina. No termodiferencial as dentinas comportaram-se semelhantemente. O esmalte bovino absorveu mais energia, indicando mudanças estruturais e apresentando comportamento estável a partir de 450ºC, enquanto que o humano continuou instável. No Termogravimétrico a dentina humana foi duas vezes mais susceptível à perda de massa. Os esmaltes apresentaram Condutividades Térmicas semelhantes. A dentina humana foi mais condutora do que a bovina. Na Dissolução a perda de massa foi mais lenta no dente humano. Na Desidratação o esmalte bovino perdeu aproximadamente 25% e o humano perdeu 2,5%. No esmalte humano houve menor Penetrabilidade de Corante, porém semelhante nas dentinas. Assim, não se deve extrapolar resultados para dente humano em relação à incorporação de água, à penetrabilidade de corante, à dissolução e ao comportamento térmico. / Bovine teeth are widely required in substitution of human teeth in in vitro researches to evaluate the behavior of dental materials. Sixth human teeth and sixth bovine teeth were used. Enamel and dentin were individually evaluated under Differential Thermal Analysis, Thermogravimetry and Thermal Conductivity. The dissolution was evaluated for different periods of time and different concentrations of acid. In the dehydration test, the fragments were placed inside a stove for different periods of time. In sorption of water, after the fragments were removed from stove, cooled and immersed in distilled water. It was weighted how much water mass the tissues absorbed. The dyeing penetrability was evaluated under Fluorescence Spectroscopy. To evaluate Vickers Micro hardness, the teeth were placed in polyester resin and polished until enamel or dentin was exposed. In the Differential Thermal the dentin behaved similarly. The bovine enamel absorbed more energy, showing structural changes and reaching stability for temperatures up to 450ºC, while human teeth remained unstable. In the Thermogravimetry, the human dentin was two times more susceptible to mass loss. Both enamels presented similar thermal conductivity. Human dentin presented better conductivity than bovine. In the dissolution, mass loss was slower for human teeth. In the dehydration, bovine enamel lost approximately 25 % while human lost 2.5%. There was smaller dyeing penetrability for human enamel however similar in dentins. Therefore, the results for human teeth may not be extrapolated when related to water absorbing, dyeing penetrability, dissolution and thermal behavior.
87

Alteração volumétrica por análise microtomográfica, solubilidade e capacidade seladora bacteriana de diferentes materiais retro-obturadores /

Espir, Camila Galletti. January 2014 (has links)
Orientador: Fábio Luiz Camargo Villela Berbert / Co-orientador: Juliane Maria Guerreiro Tanomaru / Banca: Mario Tanomaru Filho / Banca: Fernando Simões Crisci / Resumo: O objetivo deste estudo foi avaliar os materiais retro-obturadores MTA, Cimento Portland associado a 30% de óxido de zircônio (CP/ZrO2) e óxido de zinco e eugenol (OZE). Para análise microtomográfica da alteração volumétrica, cavidades retrógradas foram confeccionadas em dentina bovina e preenchidas com os materiais experimentais, sendo analisados pelo microtomógrafo Sky Scan 1176. A avaliação de solubilidade foi realizada de acordo com normas ISO 6876, por meio da diferença de massa inicial e após 7 dias de imersão em água destilada. A análise da capacidade seladora bacteriana foi realizada em dentes humanos extraídos. Cavidades retrógradas confeccionadas foram preenchidas de acordo com os materiais experimentais (n=12), além do controle positivo (n=8), sem preenchimento, e controle negativo (n=8), com impermeabilização em toda extensão. As amostras foram submetidas à infiltração utilizando cepas de Enteroccocus faecalis (ATCC 29212) em meio de cultura BHI, sendo observadas diariamente por 60 dias e a infiltração avaliada pela turbidez do meio. Os dados foram submetidos aos testes ANOVA e Tukey para solubilidade e alteração volumétrica, e Kruskall-Wallis e Dunn para capacidade seladora bacteriana. Na análise de solubilidade, não houve diferença estatística significante entre os grupos. A análise volumétrica demonstrou maior diminuição de volume para o OZE. Também foi observada maior infiltração bacteriana para o OZE. Conclui-se que MTA e CP/ZrO2 apresentam maior capacidade seladora bacteriana, que pode estar relacionada à menor alteração volumétrica. / Abstract: The present study evaluated different properties of the root end sealers MTA, Portland cement with de 30% zirconium oxide (PC/ZrO2) and zinc oxide and eugenol (ZOE). To analyze the volumetric changes by computed microtomography, bovine teeth were used in which the prepared cavities in dentine were filled according to the materials and then analyzed by Sky Scan 1176. The solubility evaluation was in accordance with ISO 6876 standards, from the difference of the original mass and after 7 days of immersion in distilled water. For analysis of bacterial sealing capacity, extracted human teeth were used. Retrograde cavities were filled according with experimental materials (n=12), besides a positive control (n = 8), no fill, and a negative control (n = 8), with waterproofing to the fullest extent. The samples were subjected to infiltration using Enteroccocus faecalis strains (ATCC 29212) in BHI culture, and observed daily for 60 days and infiltration evaluated by turbidity of the medium. Data were submitted to ANOVA and Tukey tests for solubility and volumetric change, and Kruskall-Wallis and Dunn for bacterial infiltration. In the analysis of solubility, no statistically significant difference between groups. In the analysis of solubility, no statistically significant difference between groups. Volumetric analysis showed greater volumetric reduction for ZOE, as well as greater bacterial infiltration. It was concluded that MTA and CP/ZrO2 have larger bacterial sealing ability, which may be related to lower volumetric changes observed. / Mestre
88

Physicochemical and mechanical properties, bioactivity potential and characterization of the dentin-sealer interface of experimental root sealers based on portland cement with micro and nano particulate radiopacifiers = Propriedades físico-químicas e mecânicas, potencial bioativo e caracterização da interface dentina-cimento de cimentos endodônticos experimentais à base de cimento Portland associados à radiopacificadores micro e nanoparticulados /

Viapiana, Raqueli. January 2014 (has links)
Orientador: Mário Tanomaru Filho / Banca: José Mauricio dos Santos Nunes Reis / Banca: Josette Camilleri / Banca: Marcos Húngaro Duarte / Banca: Loise Pedrosa Salles / Resumo: O cimento Portland é constituído por silicato de cálcio e a associação com aditivos e veículos conferem características que podem viabilizar seu uso como cimento endodôntico. No entanto, o cimento Portland não apresenta radiopacidade própria, o que torna necessário a adição de um agente radiopacificador à mistura para ser utilizado como material dentário. O objetivo deste estudo foi avaliar as propriedades físico-químicas e mecânicas, o potencial bioativo e caracterizar a interface dentina-cimento de cimentos endodônticos experimentas à base de cimento Portland (ES) contendo nano ou micro partículas de óxido de zircônio ou óxido de nióbio. O tempo de presa, resistência à compressão, escoamento, espessura de filme, radiopacidade, solubilidade e estabilidade dimensional foram avaliadas de acordo com a norma ISO 6876:2012, enquanto que a liberação de fomaldeído foi avaliada por meio de cromatografia gasosa. A resistência de união dentinária foi avaliada por meio de teste push-out e tanto a caracterização da microestrutura dos cimento quanto a análise do potencial bioativo foram realizadas utilizando energia dispersiva de raios-x, difractometria e espectroscopia infravermelha. A interface dentina-cimento foi avaliada com relação à penetração de microesferas fluorescentes e examinada em microscopia confocal e microscopia eletrônica de varredura associada à escaneamento por energia dispersiva de raios-x linear. Os dados foram submetidos aos testes ANOVA e Tukey (p < 0,05). Com exceção da radiopacidade, os ES apresentaram propriedades físico-químicas de acordo com as especificações ISO 6876, adequada resistência de união à dentina, potencial bioativo e promoveram selamento coronário e interação química com a dentina. / Abstract: Portland Cement is composed by calcium silicate and the association with additives or vehicles, may confer characteristics to enable the use of this cement as root canal sealer. However, Portland cement lacks in radiopacity which requires the addition of a radiopacifying agent to the mixture to be used as dental material. The purpose of this study was to assess the physicochemical and mechanical properties, the bioactivy potential and to characterize the dentin-sealers interfaces of Portland-based experimental root canal sealers (ES) containing nano or micro particles of zirconium oxide or niobium oxide. Setting time, compressive strength, flow ability, film thickness, radiopacity, solubility and dimensional stability were evaluated according to ISO 6876:2012 standards, whereas formaldehyde realease was investigated using gas-cromatography. Dentin bond strength was evaluated by push-out test and the sealer's microestruture and bioactivity potential were perfomed using X-ray energy espectroscopy, X-ray diffractometry and infrared spectroscopy. Dentin-sealers interface was assessed with respect to fluorescent microspheres penetration and it was also examined using confocal microscope and scanning electron microscope coupled to X-ray energy dispersive line scans. Data were analyzed by ANOVA and Tukey post-hoc test (p < 0.05). With the exception of radiopacity, ES showed physicochemical properties according to ISO 6876:2012 specifications, adequate dentin bond strength, great bioactivity potential and promoted coronal sealing and chemical interaction with dentin. / Doutor
89

Avaliação da atividade antimicrobiana de um reembasador resiliente combinado a um polímero antimicrobiano sobre a formação de bio-filme /

Toda, Carina. January 2013 (has links)
Orientador: Marco antonio Compagnoni / Banca: Ana Maria Pero / Banca: Janaína Habib Jorge / Banca: Maria Fulgência Costa Lima Bandeira / banca Juliê Marra / Resumo: Este estudo avaliou a atividade antimicrobiana de um reembasador resiliente Coe Soft® (RRCS) combinado ao polímero antimicrobiano poli (2 tert-butilaminoetil) metacrilato (PTBAEMA) sobre formação de biofilme de Staphyloccocus aureus, Streptococcus mutans e Candida albicans. Espécimes circulares (15mm x 3mm) do RRCS foram confeccionados (n=27), esterilizados, divididos em três grupos de acordo com as concentrações de PTBAEMA a 0% (controle), 10% e 25% e individualmente inoculados em tubos de falcon contendo 5mL de caldo RPMI para os fungos, TSB para S. aureus e BHI para S. mutans e mantidos em overnight a 37ºC em incubadora com agitação orbital a 75rpm, sendo o S. mutans em microaerofilia. Após a inoculação dos espécimes seguiu-se a formação e maturação do biofilme a 37ºC sob agitação orbital a 75rpm. Em seguida cada espécime foi transferido para tubos contendo PBS e diluições seriadas foram realizadas. Alíquotas dessas diluições foram semeadas em placas de Petri e incubadas a 37ºC por 48h. Os dados obtidos foram transformados em log (UFC+1)/mL, considerando-se α=0,05. Os resultados demonstraram que o grupo contendo 25% de PTBAEMA inibiu completamente a formação de biofilme de S. aureus e S. mutans. Uma redução significativa na contagem de S. aureus e S. mutans (Kruskal- Wallis e Dunn; p=0,001) para o grupo contendo 10% de PTBAEMA foi observada quando comparada aos valores encontrados nos respectivos grupos controle. Para C. albicans não foi encontrada diferença significante entre grupos contendo PTBAEMA e o grupo controle (ANOVA; p>0,05). Conclui-se que os RRCS contendo 10% e 25% de PTBAEMA inibiram a formação de biofilme de S. aureus e S. mutans. Entretanto não teve efeito significante na formação de biofilme de C. albicans. / Abstract: This study evaluated the antimicrobial activity of the resilient reliner Coe Soft ® (RRCS) combined with antimicrobial polymer poly (2-tert butylaminoethyl) methacrylate (PTBAEMA) on Staphylococcus aureus, Streptococcus mutans and Candida albicans biofilm formation. RRCS circular specimens were prepared (n=27), sterilized, divided into three groups according to PTBAEMA concentrations of 0% (control), 10% and 25% and inoculated into individual falcon tubes containing 5 mL of RPMI broth for fungi, TSB for S. aureus and BHI for S. mutans and kept overnight at 37°C with orbital shaking incubator at 75rpm, and S. mutans in microaerophilic. The specimens' inoculations were followed by biofilm formation and its maturation at 37°C under orbital shaking at 75rpm. After that, each sample was transferred to tubes containing PBS and serial dilutions were performed. Aliquots of these dilutions were plated in Petri dishes and incubated at 37°C for 48h. The data were transformed into log (CFU +1)/mL, considering α = 0.05. The results showed that the group containing 25% of PTBAEMA inhibited completely biofilm formation of S. aureus and S. mutans. A significant reduction in counts of S. aureus and S. mutans (Kruskal- Wallis and Dunn; p = 0.001) were found in group containing 10% of PTBAEMA when compared to the values in the corresponding control groups. C. albicans had no significant differences between groups containing PTBAEMA and the control group (ANOVA; p> 0.05). It is concluded that the RRCS containing 10% and 25% PTBAEMA inhibited the biofilmformation of S. aureus and S. mutans. However, no significant effect was found on C. albicans biofilm formation. / Doutor
90

Avaliação das propriedades térmicas, químicas e mecânica relacionando dente bovino e dente humano /

Dutra-Corrêa, Maristela. January 2005 (has links)
Orientador: José Roberto Rodrigues / Resumo: Dentes bovinos são amplamente utilizados substituindo dentes humanos em pesquisas in vitro, para avaliar o comportamento dos materiais odontológicos. Utilizaram-se sessenta dentes bovinos e sessenta humanos. Esmalte e dentina foram avaliados individualmente em Análises Termodiferencial, Termogravimétrica e Condutividade Térmica. A Dissolução foi avaliada em diferentes tempos e concentrações de ácido. No teste de Desidratação os fragmentos foram colocados em estufa por tempos diferentes. Na Incorporação de Água, após a retirada dos fragmentos da estufa, foram resfriados e depois imersos em água destilada. Verificou-se o quanto o tecido incorporou de água em sua massa. A Penetrabilidade de Corante foi avaliada pela Espectroscopia de Fluorescência. Para avaliar a Microdureza Vickers os dentes foram incluídos em resina de poliéster e polidos até expor esmalte ou dentina. No termodiferencial as dentinas comportaram-se semelhantemente. O esmalte bovino absorveu mais energia, indicando mudanças estruturais e apresentando comportamento estável a partir de 450ºC, enquanto que o humano continuou instável. No Termogravimétrico a dentina humana foi duas vezes mais susceptível à perda de massa. Os esmaltes apresentaram Condutividades Térmicas semelhantes. A dentina humana foi mais condutora do que a bovina. Na Dissolução a perda de massa foi mais lenta no dente humano. Na Desidratação o esmalte bovino perdeu aproximadamente 25% e o humano perdeu 2,5%. No esmalte humano houve menor Penetrabilidade de Corante, porém semelhante nas dentinas. Assim, não se deve extrapolar resultados para dente humano em relação à incorporação de água, à penetrabilidade de corante, à dissolução e ao comportamento térmico. / Abstract: Bovine teeth are widely required in substitution of human teeth in in vitro researches to evaluate the behavior of dental materials. Sixth human teeth and sixth bovine teeth were used. Enamel and dentin were individually evaluated under Differential Thermal Analysis, Thermogravimetry and Thermal Conductivity. The dissolution was evaluated for different periods of time and different concentrations of acid. In the dehydration test, the fragments were placed inside a stove for different periods of time. In sorption of water, after the fragments were removed from stove, cooled and immersed in distilled water. It was weighted how much water mass the tissues absorbed. The dyeing penetrability was evaluated under Fluorescence Spectroscopy. To evaluate Vickers Micro hardness, the teeth were placed in polyester resin and polished until enamel or dentin was exposed. In the Differential Thermal the dentin behaved similarly. The bovine enamel absorbed more energy, showing structural changes and reaching stability for temperatures up to 450ºC, while human teeth remained unstable. In the Thermogravimetry, the human dentin was two times more susceptible to mass loss. Both enamels presented similar thermal conductivity. Human dentin presented better conductivity than bovine. In the dissolution, mass loss was slower for human teeth. In the dehydration, bovine enamel lost approximately 25 % while human lost 2.5%. There was smaller dyeing penetrability for human enamel however similar in dentins. Therefore, the results for human teeth may not be extrapolated when related to water absorbing, dyeing penetrability, dissolution and thermal behavior. / Mestre

Page generated in 0.0199 seconds