• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação dimensional de modelos de gesso em função de diferentes tecnicas e materiais de moldagem elastomericos / Dimensional evaluation of stone models in function of different techniques and elastomeric impression materials

Vitti, Rafael Pino, 1984- 02 November 2009 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Dissertação (mestrado) - Universidade EStadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T09:01:20Z (GMT). No. of bitstreams: 1 Vitti_RafaelPino_M.pdf: 8432913 bytes, checksum: 82945cbea8656d59d74e27161eec09f2 (MD5) Previous issue date: 2009 / Resumo: O objetivo neste estudo foi medir e comparar a precisão dimensional de modelos de gesso confeccionados a partir de três técnicas de moldagem com dez diferentes elastômeros. Um modelo em cera, simulando um arco dental mandibular, teve retirados os dentes 44, 45 e 46 a fim de avaliar possíveis diferenças de precisão entre os lados direito e esquerdo, pelo maior volume de material de moldagem do lado direito, o que poderia acarretar em maior contração e conseqüentemente maior alteração desse lado. A partir desse modelo em cera foi obtido um modelo metálico padrão com pontos de referência nos dentes 33 (CE), 43 (CD), 37 (ME) e 47 (MD) que foi utilizado para a realização das moldagens. Foram medidas as distâncias entre os dentes CE-CD, ME-MD, CEME e CD-MD. Moldeiras metálicas de estoque foram usadas para as técnicas do reembasamento e dupla mistura. Já para a técnica da moldeira individual, moldeiras de resina acrílica foram confeccionadas com alívio interno de aproximadamente 2mm. Adesivos específicos para cada material foram usados nas moldeiras individuais, para promover adesão na moldeira. Todos os procedimentos de moldagem foram realizados em uma sala com temperatura e umidade relativa controladas. A manipulação dos materiais foi feita segundo as instruções dos fabricantes. O movimento de retirada da moldeira, após a presa do material de moldagem, foi padronizado por meio de um equipamento pneumático evitando possíveis distorções no molde. Os modelos de gesso foram vazados após trinta minutos da obtenção dos moldes, para promover a recuperação elástica dos materiais. Foram confeccionados cinco corpos-de-prova para cada marca comercial de elastômero e técnica de moldagem, totalizando cento e trinta amostras. Após 24 horas, foi feita a separação molde-modelo, sendo o modelo observado em microscópio comparador com 30x de aumento. Três leituras foram feitas em cada uma das distâncias analisadas, obtendo-se uma média que foi, posteriormente, analisada estatisticamente, por meio da análise de variância com três fatores ou com dois fatores e as médias comparadas pelo teste de Tukey (5%). Os resultados demonstraram que os silicones polimerizados por adição foram os materiais que mostraram melhores resultados de precisão dimensional dos modelos. Os silicones polimerizados por condensação apresentaram os piores resultados. Todas as distâncias mensuradas apresentaram alterações lineares negativas (contração), sendo que as distâncias ântero-posteriores (CEME e CD-MD) sofreram mais alterações quando comparadas com as distâncias transversais (CE-CD e ME-MD). Num contexto geral, não houve diferença entre as distâncias MD-CD e ME-CE. Também não foram encontradas diferenças entre as técnicas de moldagem. A precisão dos modelos de gesso foi mais afetada pelos materiais do que pela técnica de moldagem. / Abstract: The aim of this study was assess and compare the dimensional accuracy of stone models made from of three impression techniques and ten different elastomeric materials. A wax model, simulating a lower dental arch, had removed the teeth 44, 45 and 46 in order to evaluate possible differences of accuracy between the right and left sides, by the bigger volume of impression material on the right side that could lead in bigger contraction and, consequently, bigger change in this side. From this wax model was obtained a metallic master model with reference points in the teeth 33 (LC), 43 (LM), 37 (RC) and 47 (RM) that was used for the accomplishment of the impressions. The distances were measured among the teeth LC-RC, LM-RM, LC-LM and RC-RM. Stock metallic trays were used for the putty/wash technique and double mix technique. For the single mix technique custom acrylic resin trays were made with internal relief of approximately 2mm. Specific adhesives for each material were used in the custom trays, to promote adhesion in the trays. All impressions procedures were made at room with temperature and relative humidity controlled. The materials handled were made following the manufacturers' instructions. The tray movement, after the impression aterial set, was standardized through of a pneumatic equipment avoiding possible distortions in the mold. The stone models were pouring after thirty minutes of the molds obtaining, to promote the materials elastic recovery. Five specimens were made for each elastomeric material commercial mark and impression technique, totaling one hundred thirty samples. After 24 hours, the separation mold/model was made, being the model observed in measuring microscope at 30x magnification. Three measurements were made in each one of the analyzed dimensions, getting a mean that was later analyzed statistically through of variance analysis three-way or two-way and the means compared by Tukey's test (5%). The results demonstrated that addition silicones were the materials that showed better results of models dimensional accuracy. The condensation silicones showed the worst results. All distances assessed showed negative linear change (contraction), being that the anteroposterior distances (LCLM and RC-RM) suffered more changes when compared with the transversal distances (LC-RC and LM-RM). In general, there wasn't difference between the distances LC-LM and RC-RM. There wasn't found differences between the impression techniques. The stone models accuracy was more affected by the materials than the impression technique. / Mestrado / Mestre em Materiais Dentários
42

Avaliação in vitro da liberação de flúor de cimentos de ionômero de vidro forradores e cimentantes.

Renata Bastos Del'Hoyo Fernandes 28 March 1996 (has links)
O objetivo deste estudo in vitro foi avaliar e comparar o padrão e a quantidade de liberação de flúor de cimentos de ionômero de vidro forradores e cimentantes após períodos de 24 horas, 7 dias e 28 dias em água desionizada. Foram confeccionados 6 corpos de prova em forma de disco para cada material e cada período de leitura que, após a reação de endurecimento inicial, foram suspensos em recipientes plásticos contendo 18 mL de água desionizada. No momento da leitura, realizada a cada 6 horas no período de 24 horas, a cada 24 horas no período de 7 dias e a cada 7 dias no período de 28 dias, adicionou-se ao meio de armazenagem 2 mL de solução tampão TISAB III. A concentração de íons flúor em solução foi avaliada mediante leitura potenciométrica utilizando-se um aparelho analisador de íons. Vidrion C e XR Ionomer apresentaram as maiores quantidades de liberação de flúor. Ketac-Bond, Vitrebond, Ketac-Cem, GC Fuji I e Shofu I ocuparam uma posição intermediária e o Zionomer pó/líquido liberou a menor quantidade de flúor. Contudo, o padrão de liberação de flúor foi semelhante para todos os materiais testados. / The objective of the present in vitro study was to evaluate and compare the pattern and the quantity of fluoride release of lining and luting glass ionomer cements after 24 hours, 7 days and 28 days in de-ionized water. Six disc-shaped specimes were made for each material and for each reading period. After the initial hardening reaction, they were pierced and suspended in plastic containers with 18 mL of de-ionized water. Readings were carried out every six hours in the 24-hour period, every 24 hours in the 7- day period, and every 7 days in the 28-day period, when 2 mL of TISAB III buffer solution was added. The concentration of fluoride ions in solution was evaluated through potenciometric readings using an ion analyser device. Vidrion C and XR Ionomer showed the highest quantity of fluoride release. Ketac-Bond, Vitrebond, Ketac-Cem, GC Fuji I and Shofu I were intermediary in rank, whereas powder/liquid Zionomer released the least quantity of fluoride. However, the pattern of fluoride release was the same to all the tested materials.
43

Resistência à remoção de braquetes ortodônticos sob ação de diferentes cargas contínuas

Carla Giannini Francischone 14 June 2006 (has links)
O objetivo deste trabalho foi: 1 - testar se existe alteração na resistência adesiva de dois cimentos utilizados na colagem de acessórios ortodônticos ao esmalte dental bovino, sendo um de polimerização química (Concise Ortodôntico) e outro fotpolimerizável (Transbond XT), após a aplicação de cargas contínuas, mediante testes de cisalhamento, 2 - observar se há diferença entre as cargas utilizadas e 3 - analisar o tipo de falha que ocorrida no momento do deslocamento dos braquetes para os dois cimentos testados. Foram utilizados para este estudo 80 dentes bovinos, 80 braquetes metálicos (Morelli Ortodontia - Braquete Edgewise/ Rickets para colagem), e pesos com 30g, 70g e 120g. O esmalte bovino foi condicionado com ácido fosfórico a 37% por 1 minuto e depois lavado e seco. A aplicação dos adesivos, manipulação e aplicação dos dois cimentos foram feitas de acordo com as instruções dos fabricantes. Para a padronização da espessura de cimento sob o braquete, foi utilizada uma Agulha Maior de Gilmore, posicionada sobre o braquete, de modo a fazer pressão durante a presa dos cimentos. Após 24 horas, os 80 braquetes colados com Concise e Transbond XT aos dentes foram submetidos às cargas contínuas de 30g, 70g e 120g, além do grupo controle onde os espécimes não receberam carga alguma, sendo 10 corpos de prova para cada teste. Os espécimes ficaram imersos em água filtrada por 28 dias dentro de uma estufa a 37°C. Depois deste período, as amostras foram submetidas a testes de cisalhamento em uma Máquina de Ensaios Universal Kratos, através de um dispositivo com alça metálica acoplado à célula de carga com 500kgf a uma velocidade de 0,5mm/min. Os resultados foram registrados e enviados para análise estatística dos resultados através do teste de Análise de Variância a dois critérios de classificação. Ficou concluído que: 1 - o cimento Concise apresentou maior resistência à remoção que o cimento Transbond XT para todas as cargas utilizadas, 2 - não houve diferença estatisticamente significante entre as três cargas utilizadas para os dois cimentos testados; 3 - com relação ao tipo de falha ocorrida no momento da fratura, conforme ocorreu o aumento da carga, a porcentagem de fratura do esmalte diminuiu para o Concise, ao contrário do cimento Transbond XT , onde a porcentagem de fratura de esmalte se manteve constante com o aumento das cargas. Os dois cimentos testados obtiveram resultados aceitáveis para a utilização clínica. / The aim of this study was: 1) to test differences on bond strength between auto-cured (Concise) and light-cured (Transbond XT) cements after static loading and shear test; 2) to observe whether differences exist among static loads and 3) to analyze failure mode after bracket displacement. Eighty bovine teeth and metallic orthodontic brackets (Morelli Ortodontia Braquete Edgewise/Rickets) were tested after static loads of 30, 70 and 120 grs. Bovine enamel was conditioned with 37% phosphoric acid gel for one minute, rinsed and dried. Adhesives were applied and brackets were bonded according to manufacturer\' s instructions. Cement thickness was standardized with the use of a heavier Gilmore needle. After 24 hours, half of the specimens were submitted to the static loads of 30, 70 and 120grs. Control groups remained unloaded. Then, specimens were immersed in distilled water for 28 days at 37oC. Afterwards, orthodontic brackets were attached to a loop wire and submitted to a shear force (Máquina de Ensaios Kratos Universal Kratos) under a crosshead speed of 0.5mm/min and load cell of 500Kgf. A two-way ANOVA test (?=0.05) was used to detect significant interactions between cements and static loads. It was concluded that: 1) The Concise cement showed more statistically significant bond strength values than the TransbondXT cement for all static loads; 2) No statistically significant differences were observed regarding static loads for all cements tested and 3) Higher static loads provided less enamel fracture in the Concise group after shear test, whereas in the Transbond XT the rate of enamel fracture remained unchanged regardless of previous load applied. The two tested cements provided acceptable results for clinical application.
44

Análise comparativa da adaptação marginal de componentes pré-fabricados e fundidos sobre pilares ceraone.

Lussara Azevedo Manhães 16 June 1999 (has links)
O critério mais importante para a aceitabilidade clínica de uma restauração indireta é o grau de adaptação marginal. Em próteses sobre implantes também torna-se necessária a obtenção de adequada adaptação marginal para a manutenção da saúde periimplantar e obtenção da longevidade da prótese. Avaliou-se “in vitro” a adaptação marginal na interface intermediário CeraOne(Nobel Biocare- Gotemburgo, Suécia) e cinco tipos de coifas: coifa cerâmica pré-fabricada CeraOne(DCA 127), In Ceram(Vita-Alemanha), coifa préfabricada poliacrílica do sistema CeraOne(DCA 131), IPS Empress(Ivoclar- Schaan, Liechtenstein) e Fortune(Williams- Amherst, NY, Labordental-São Paulo). As coifas obtidas foram assentadas em um intermediário CeraOne(SDCA 334) e a adaptação marginal foi avaliada, segundo critérios de ajuste e desajuste marginal, em 6 pontos, determinados pelo sextavado do intermediário. De acordo com a análise estatística dos resultados, foi possível concluir que as coifas cerâmicas pré-fabricadas CeraOne(DCA 127) exibiram a maior quantidade de ajustes e os menores valores de desajuste, sendo consideradas a melhor opção restauradora sobre intermediários CeraOne. As coifas In Ceram apresentaram resultados muito satisfatórios, assim como as coifas IPS Empress. Esses dois sistemas são considerados aceitáveis para a utilização sobre intermediários CeraOne, como segunda opção e em casos selecionados. As coifas de porcelana fundida sobre refratário não exibiram resultados satisfatórios, quando comparadas aos demais grupos, sendo considerada uma técnica desaconselhável para ser utilizada sobre intermediários CeraOne. / The most important rule in the clinical acceptability of na indirect restoration is the marginal fit. Implant-supported restorations also need acceptable margins for the maintenance of peri-implant health and protheses longevity. The purpose of this study is to evaluate marginal fit of the abutment CeraOne(Nobel Biocare SDCA 334- Gotemburg, Sweden) “in vitro” as well as five kinds of ceramic caps: CeraOne prefabricated ceramic cap(DCA 127), In Ceram(Vita-Germany), CeraOne prefabricated polymethyl methacrylate cap(DCA 131), IPS Empress(Ivoclar- Schaan, Liechtenstein) and Fortune(Williams- Amherst, NY, Labordental, São Paulo). The caps were seated on the CeraOne abutment and the marginal fit was examined under microscope according to the fit and misfit criteria in six faces around the margins. The results have shown that the best marginal fit was CeraOne prefabricated ceramic caps. This system is considered the first choice in the protocol for CeraOne restoration. The In Ceram and IPS Empress caps have presented satisfactory results, but IPS Empress has shown less fit and more discrepancy in comparison with In Ceram, probably due to the previous misfit of CeraOne prefabricated polymethyl methacrylate cap. These last two systems are considered acceptable to use in abutment CeraOne, but as a second option and in selected cases. The Fortune caps have not presented satisfactory results. Thus, this system is considered inadvisable for use with abutment implants.
45

Avaliação da hiperestesia dentinária após tratamento em diferentes formulações à base de oxalato de potássio utilizando-se um placebo como controle.

Ana Christina Bonato Figueiredo Martineli 24 June 1999 (has links)
A hiperestesia dentinária é uma das mais antigas queixas de desconforto dos pacientes e, devido à sua alta incidência e diversidade de tratamentos sugeridos na literatura, novos produtos devem ser avaliados quanto ao efeito e aplicabilidade. O propósito deste estudo foi avaliar as respostas imediata e mediata de 94 dentes (caninos e pré-molares), que apresentavam algum grau de sensibilidade dentinária (1, 2 ou 3) de acordo com a Escala de Medida Verbal (EMV) aos estímulos sonda e ar, após a aplicação de três formulações à base de oxalato de potássio: Oxa-Gel®, Solução Experimental 1 e Solução Experimental 2, tendo um placebo como controle. Cada formulação de oxalato de potássio e o placebo foram aplicados passivamente por 3 minutos na superfície da dentina úmida, sendo o excesso de material removido posteriormente. O grau de sensibilidade foi avaliado antes (baseline) e imediatamente após a aplicação de cada formulação com um intervalo de 7 dias. Os resultados obtidos após a quarta aplicação foram denominados resultados imediatos e, após 6 meses, resultados mediatos. Os escores foram submetidos à análise estatística através dos testes de Kruskal-Wallis e de Friedman two-way ANOVA (p< 0,05). A aplicação de todos os materiais, inclusive o placebo, independente do tempo avaliado e dos estímulos utilizados, resultou em uma redução estatisticamente significante na hiperestesia dentinária podendo essa redução prolongar-se até seis meses. Houve uma tendência de respostas mais severas ao estímulo ar quando comparado ao estímulo sonda antes do tratamento, sendo que a hiperestesia provocada pela sonda se mostrou mais persistente ao longo do tratamento. O tratamento da hiperestesia dentinária está sujeito a variáveis clínicas que podem aumentar ou diminuir o efeito anti-hiperestésico dos agentes estudados.
46

Avaliação de algumas propriedades físico-químicas do cimento AH Plus puro e acrescido de hidróxido de cálcio

Marco Antonio Hungaro Duarte 01 October 1999 (has links)
Algumas propriedades físico-químicas como radiopacidade, tempo de presa, escoamento, pH, liberação de cálcio e infiltração apical do cimento AH Plus puro ou modificado foram analisadas e comparadas in vitro às do óxido de zinco e eugenol. As modificações realizadas no AH Plus constaram do acréscimo de 5% e 10% de hidróxido de cálcio em peso. Para análise da radiopacidade, os cimentos foram acondicionados em anéis com 10 mm de diâmetro e 2mm de altura de acordo com norma no 57 da ADA e a determinação dos valores se deram através do sistema de imagem digital Digora e depois foram convertidos em mm de Al. Para o teste de tempo de presa os cimentos, também, foram colocados em anéis metálicos e com auxílio de agulha Gilmore de 453,6 gr de peso determinou-se o tempo de presa final. Na avaliação do escoamento, os cimentos foram preparados e 0,5mL deles foram colocados sobre uma placa de vidro e, em seguida, outra placa com um peso totalizando 120 gramas foi colocada sobre o cimento e após 10 minutos mediu-se o maior e menor diâmetro do mesmo e a média dos dois foi o valor do escoamento. Na análise da infiltração apical dentes caninos humanos tiveram seus canais instrumentados e a seguir as superfícies externas impermeabilizadas, para então, proceder-se a obturação pela técnica do cone único com os cimentos em estudo. Na seqüência foram imersos em azul de metileno a 2% durante 7 dias. Finalizado esse período, os dentes foram removidos do corante, lavados, raspados seccionados e a infiltração do marcador foi determinada em microscópio óptico munido de ocular micrometrada. Para análise do pH e liberação de cálcio, os cimentos foram colocados em tubos com 1cm de comprimento e 1 mm de diâmetro e, posteriormente, imersos em 20 mL de água deionizada. Nos períodos de 24h, 48h, 7dias, 14dias e 30 dias, 4mL da solução eram removidos e, então, se media o pH com auxílio de pHmetro e a liberação de cálcio através de espectrofotômetro de absorção atômica. Os resultados mostraram que o acréscimo de hidróxido de cálcio ao cimento AH Plus não interferiu significantemente na radiopacidade, não alterou o tempo de presa, melhorou o escoamento, principalmente com o acréscimo de 5%, favoreceu significantemente o selamento apical e propiciou um pH mais alcalino, bem como liberação de ions cálcio. Com relação ao AH Plus puro, evidenciou-se um baixo selamento apical e um escoamento muito elevado. / Some physico-chemical properties as radiopacity, cure time, flow, pH, calcium release, and apical leakage of AH Plus plain or modified were analyzed and compared in vitro to the ones of zinc oxide eugenol. The changes performed in the Ah-plus cement implied in a 5% and 10% increase of calcium hydroxide in weight. For the radiopacity analysis, the cements were placed in 10mm diameter and 2mm hight rings according to the nº 57 ADA norm and the values determination were given by the Digora digital image system and latter converted in mm of Al. For the cure time test, the cements were also placed in metal rings and with the aid of a Gilmore needle weighing 453.6 it was determined the final cure time. In the flow assessment, the cements were prepared and 0,5mL of them were placed on a glass slab and, immediately, another slab with a weight totalizing 120 gr was placed on the cement and after 10 minutes the largest and smaller cement diameter was measured and the average of both was considered the flow value. For the assessment of apical leakage, human canine or cuspid teeth had their canals instrumented and the external surfaces impermealized before proceding the obturation by the simple cone technique with the cements under study. In sequence the teeth were immersed in methilene blue 2% during 7 days. After this period, the teeth were removed from the die, washed, scrubbed, seccioned and the marker leakage was determined in an optical microscope with micrometered ocular. For the pH and calcium release assessment, the cements were placed in tubes measuring 1cm in length and 1mm in diameter and later immersed in 20mL of deionized water. Measurements were made in 24 hours, 48 hours, 7 days, 14 days and 30 days, when 4mL of the solution were removed to assess the pH with the aid of a pHmeter, and the calcium release through a spectrophometer of atomic absorption. The results showed that the increase of calcium hydroxide to the AH Plus cement did not significantly interfere in the radiopacity, did not alter the cure time, improved the flow, specially with the addition of 5%, significantly favored the apical sealing and provided a more alcaline pH, as well as calcium íons release. As to the plain AH Plus, it was evidenced a low apical sealing and a very high flow rate.
47

Influence of diluent isobornyl methacrylate monomer (IBOMA) on physico-mechanical properties of experimental resin = Influência do monômetro diluente isobornil metacrilato (IBOMA) em propriedades físico-mecânicas de resinas experimentais / Influência do monômetro diluente isobornil metacrilato (IBOMA) em propriedades físico-mecânicas de resinas experimentais

Martins, Aurealice Rosa Maria, 1986- 22 August 2018 (has links)
Orientador: Mário Alexandre Coelho Sinhoreti / Texto em português e inglês / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T12:41:50Z (GMT). No. of bitstreams: 1 Martins_AurealiceRosaMaria_M.pdf: 1504844 bytes, checksum: 8845f1f591540a2f3ae0518e7fc047e2 (MD5) Previous issue date: 2013 / Resumo: O objetivo neste estudo foi avaliar a utilização do isobornil metacrilato (IBOMA) como monômero diluente associado ou não ao TEGDMA, em resinas experimentais à base de Bis-GMA. No Capítulo 1, o grau de conversão (GC), a resistência à flexão (RF), o módulo de elasticidade (ME), a resistência máxima à tração (RMT), a profundidade de polimerização (PP) e a contração volumétrica (CV) foram avaliados. No Capítulo 2, a dureza Knoop (KHN), a densidade de ligações cruzadas (DLC) e a sorção (SOR) foram avaliadas. Nove formulações de matriz resinosa foram confeccionadas de acordo com o monômero diluente IBOMA, TEGDMA ou IBOMA / TEGDMA) nas proporções: Bis-GMA/IBOMA 60/40, 50/50, 40/60% em peso, Bis-GMA/TEGDMA 60/40, 50/50, 40/60% e quando associados Bis-GMA/IBOMA/TEGDMA, 60/20/20, 50/25/25 e 40/30/30%). Para o GC, os espécimes em formato de barras (7 x 2 x 1 mm / n=10) foram avaliados em espectroscopia de infravermelho transformada de Fourier (FTIR). Em seguida, os testes de RF e MF foram conduzidos numa máquina de ensaios universal, na mesma amostra utilizada para a avaliação do GC. A PP foi avaliada em amostras (n=5) confeccionadas, seguindo as instruções da ISO 4049. A densidade dos espécimes antes (?u) e após (?c) a fotoativação foram utilizadas para avaliar a CV, utilizando o princípio de Arquimedes. DLC foi avaliada através do teste de amolecimento; testes de KHN foram realizados antes e depois da imersão em etanol absoluto, durante 24 horas. O teste de SOR (n=5) foi realizado de acordo com as normas da ISO 4049. Os dados foram submetidos à análise de variância de dois fatores e teste de Tukey (?=0,05). As resinas Bis-GMA/TEGDMA apresentaram maiores valores de GC do que as resinas que continham IBOMA, exceto para a mistura com 60% em peso de Bis-GMA (p?0,001). As resinas com IBOMA apresentaram menor RF, MF e RMT do que outros grupos (p?0,001). A PP para as misturas de IBOMA, foi menor do que para os outros grupos (p?0,001), exceto para as resinas que continham elevada concentração de monômero diluente (Bis-GMA/TEGDMA, 40/60% em peso). As resinas Bis-GMA/ TEGDMA 60/40% e Bis-GMA/IBOMA/TEGDMA 60/20/20% apresentaram os valores mais elevados de dureza Knoop e as resinas Bis-GMA/IBOMA 50/50% e Bis-GMA/IBOMA 40 / 60% apresentaram os menores valores DLC. As resinas que continham TEGDMA apresentaram maior SOR. Pode-se concluir que o IBOMA diminuiu a contração volumétrica. No entanto, os copolímeros que contêm IBOMA sozinho apresentaram menores propriedades físico-mecânicas do que os sistemas Bis-GMA/TEGDMA e Bis-GMA/TEGDMA/IBOMA / Abstract: The purpose in this study was to evaluate the use of isobornyl methacrylate IBOMA as diluent monomer in the Bis-GMA/TEGDMA blends. In the Chapter 1 the degree of conversion (DC), flexural strength (FS), elastic modulus (EM), maximum tensile strength (MTS), depth of cure (DCU) and volumetric shrinkage (VS) were evaluated; In the Chapter 2 the Knoop hardness (KHN), crosslink density (CLD) and sorption (WS) were evaluated. Nine resin matrix formulations were made according to diluent monomer IBOMA, TEGDMA or IBOMA/TEGDMA in the following proportions: Bis-GMA/IBOMA 60/40, 50/50, 40/60 wt%, Bis-GMA/TEGDMA 60/40, 50/50, 40/60 wt% and when associated Bis-GMA/IBOMA/TEGDMA, 60/20/20, 50/25/25 e 40/30/30 wt%. DC was evaluated in bars (7 x 2 x 1 mm/ n=10) by Fourier transformed infrared spectroscopy (FTIR). FS and FM tests were conducted in a universal test machine in the same sample used to DC evaluation. DCU was evaluated in samples (n=5) made following the ISO 4049:2009 directions. The densities of samples before (?u) and after (?c) photoactivation were used to evaluate the VS using the Archimedes principle. CLD was evaluated through softening test; KHN tests were performed before and after immersion in absolute ethanol for 24 h. WS test (n = 5) was performed following the ISO 4049:2009 directions. Data were submitted to two-way ANOVA and Tukey?s test (?=0.05). The resins Bis-GMA/TEGDMA showed higher DC than resins containing IBOMA, except for the blend with 60 wt% Bis-GMA (p?0.001). The blends with IBOMA showed lower FS, EM and MTS than other groups (p?0.001). DCU for IBOMA blends was lower than other groups (p?0.001), except for the highest concentration of diluent monomer (Bis-GMA/TEGDMA, 40/60 wt%). The resins Bis-GMA/TEGDMA 60/40% and Bis-GMA/IBOMA/TEGDMA 60/20/20% showed the highest KHN values of and resins Bis-GMA/IBOMA 50/50% and Bis-GMA/IBOMA 40/60% showed the lowest CLD values. The resins containing TEGDMA showed higher WS. It can be concluded that IBOMA decrease the volumetric shrinkage. However, copolymers containing IBOMA alone showed lower physical-mechanical properties than Bis-GMA/TEGDMA and Bis-GMA/IBOMA/TEGDMA systems / Mestrado / Materiais Dentarios / Mestra em Materiais Dentários
48

Análise do comportamento da luz em diferentes comprimentos de onda no interior de materiais restauradores odontológicos indiretos / Light behavior analisys at different wavelengths in indirect dental restorative materials

Pacheco, Rafael Rocha, 1987- 03 January 2013 (has links)
Orientador: Marcelo Giannini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T14:52:05Z (GMT). No. of bitstreams: 1 Pacheco_RafaelRocha_M.pdf: 2265970 bytes, checksum: 2ea85fa1c09029765d270c2e28f5ebf7 (MD5) Previous issue date: 2013 / Resumo: O objetivo do estudo foi avaliar o comportamento da luz, em diferentes comprimentos de onda, através de materiais restauradores indiretos com diferentes espessuras. A análise da passagem de luz foi realizada, através de quatro materiais restauradores odontológicos confeccionados pela técnica do CAD/CAM: uma resina composta indireta (RC) (Lava Ultimate, 3M ESPE), uma cerâmica feldspática (CF) (VitaBlocs, VITA) e duas cerâmicas à base de zircônia (ZK) (Katana, Noritake) e (ZL) (Lava, 3M ESPE). A perda total de irradiância, assim como a perda de energia em comprimentos de onda específicos (azul e violeta) foram analisados. As amostras sinterizadas tinham as dimensões de 20x20 mm, com variação na espessura: 0,5 mm, 1,0 mm, 1,5 mm e 2,0 mm (n=5). Uma fonte de luz de arco de plasma de alta potência com amplo espectro de luz foi utilizada (Arc Light II, Air Technologies). A caracterização dessa fonte de luz foi realizada através da avaliação da irradiância (mW/cm2), determinação dos espectros emitidos pela fonte de luz e padrão de saída pela ponta do aparelho. Para avaliar a quantidade de luz que passa através do material foi utilizado um espectroradiômetro (DAS 2100, Labsphere Inc.). Os corpos de prova foram posicionados sobre a superfície de uma lamínula de vidro que estava localizada na esfera integradora. O aparelho fotoativador foi posicionado de forma que a ponta do aparelho tocasse levemente e paralelo à superfície da amostra. Os dados foram tabulados e submetidos à análise estatística (análise de variância de dois fatores e teste de Tukey (?=0,05)). A interposição do material restaurador com 0,5 mm de espessura provocou uma perda de energia por volta de 60% e o aumento da espessura do material provocou redução da irradiância através dos mesmos. O material que apresentou menor perda de energia nas espessuras de 1,0 a 2,0 mm foi CF. A RC com espessura de 0,5 mm apresentou perda de energia de 56,2% e, com o aumento dessa espessura para 1,0 mm, essa perda de energia aumentou para 75,4%, semelhante à perda observada nas cerâmicas à base de zircônia. Os materiais RC, ZK e ZL apresentaram os maiores valores de perda de energia irradiante em até 1,0 mm de espessura. Com 1,5 mm e 2,0 mm, os materiais que apresentaram maior perda de energia foram: RC e ZK. Para todos os materiais, observou-se aumento significativo na perda de energia com o aumento da espessura do material e essa perda de energia foi dependente do tipo de material protético. A luz violeta (350 a 425 nm) apresentou menor capacidade de penetração quando comparada a luz azul para todas as espessuras e tipos de material restaurador indireto / Abstract: The aim of this study was to evaluate the light behavior, in different wavelengths, through different restorative materials with different thicknesses. The analysis was conducted using four dental restorative material obtained by the technique of CAD/CAM technology: an indirect composite resin (CR) (Ultimate Lava, 3M ESPE), a feldspathic ceramic (FC) (VITABLOCS, VITA) and two zirconia based ceramics (ZK) (Katana, Noritake) and (ZL) (Lava, 3M ESPE). The total loss of irradiance as well as the loss of energy at specific wavelengths (blue and violet) was analyzed. The sintered samples had dimensions of 20x20 mm, with a variation in thickness of 0.5 mm, 1.0 mm, 1.5 mm and 2.0 mm (n = 5). A plasma arc light source with high power and broad spectrum of light was used (Arc Light II, Air Technologies). The characterization of this light source was performed by evaluating the irradiance (mW/cm2), determining the spectra emitted by the light source and the output pattern on the tip of the device. To assess the amount of light passing through the material a spectroradiometer was used (DAS 2100, Labsphere Inc.). The specimens were placed on the surface of a thin glass (0.1 mm) located on the opening of the integrated sphere. The tip of the curing unit was positioned in parallel and lightly touching the sample surface. Data were tabulated and subjected to statistical analysis (two way ANOVA and Tukey test (? = 0.05)). The interposition of a restorative material of 0.5 mm thickness caused a loss of energy of approximately 60% and with the increase of the material thickness there was a reduction of the irradiance. The material that showed less energy loss in thickness from 1.0 to 2.0 mm was FC. CR with a thickness of 0.5 mm showed energy loss of 56.2%, and with 1.0 mm, this energy loss increased to 75.4%, similar to the loss observed in zirconia based ceramics. CR, ZK and ZL showed the highest values of radiant energy loss by up to 1.0 mm thick. With 1.5 mm and 2.0 mm, the materials with higher energy loss were: CR and ZK. For all materials, there was a significant increase in energy loss by increasing the thickness of the material and that energy loss is dependent on the type of indirect material. The violet light (350-425 nm) showed lower penetration capability compared to blue light for all thicknesses and types of indirect restorative material / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
49

Influencia do tempo de armazenagem inicial na resistencia a tração de cimentos resinosos unidos a dentina

Chaves, Eclerion 25 October 2002 (has links)
Orientador : Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T13:58:39Z (GMT). No. of bitstreams: 1 Chaves_Eclerion_D.pdf: 2686935 bytes, checksum: a0aae1903153a990c6baf47e2d25878c (MD5) Previous issue date: 2002 / Resumo: O objetivo deste estudo foi avaliar o efeito do tempo de armazenagem inicial na resistência à tração de três cimentos resinosos unidos à dentina. Foram utilizados 120 dentes bovinos. Os dentes foram embutidos, desgastados com lixas de granulação 220 e 600 e limpos em ultra-som. A seguir foram divididos em 3 grupos contendo 20 amostras: Grupo I foi usado o Cimento Rely X; Grupo II, Cimento Enforce e Grupo III, Cimento Dual Cement. As amostras de cada grupo foram cimentadas com os materiais preparados de acordo com as instruções de cada fabricante. A seguir, os dentes foram embutidos aos pares e posicionados em uma matriz, com as superfícies tratadas em contato entre si para o procedimento de fixação com o cimento resinoso. A resina foi fotopolimerizada por 160 segundos e os corpos-de-prova armazenados a 37° C e 100% de umidade relativa. A seguir, com o auxílio de uma matriz metálica, os corpos-de-prova foram submetidos ao ensaio de tração em uma máquina de ensaio universal INSTRON (modelo 4411) a velocidade de 1 mm/min. Metade das corpos-de-prova foram tracionadas após 30 minutos e a outra metade após 24 horas. Os resultados obtidos foram submetidos à análise de variância e ao teste de Tukey (p<0,05%). As médias obtidas foram as seguintes: Grupo I, 30 minutos = 2,53 (+0,49) MPa; 24 horas = 2,90 (+1, 12) MPa; Grupo II, 30 minutos = 1,65 (+0,46) MPa, 24 horas = 1,94 (+0,43) MPa; Grupo III, 30 minutos = 4,24 (+1,26) MPa; 24 horas = 6,14 (+01,80) MPa. Após o ensaio de resistência à tração, as superfícies fraturadas e representativas dos corpos-de-prova foram analisadas sob microscopia eletrônica de varredura para determinar o predomínio do padrão de fratura na interface. Tendo por base os resultados obtidos e discutidos na pesquisa podemos concluir que Os valores médios de resistência à tração, para os grupos I e II, obtidos a partir de corpos-de-prova tracionados nos períodos de 30 minutos não diferiram estatisticamente (p<0,05) dos tracionados em 24 horas, com exceção do grupo III que apresentou diferença estatística. Os valores médios de resistência á tração obtidos individualmente para os grupos I (Re/y X), grupo II (Enforce) e III (Dua/ Cement) apresentaram diferenças estatísticas significantes entre si (P<0,05). Comparando-se os tempos e os valores obtidos, verifica-se uma proporcionalidade direta entre o tempo e a resistência, o que implica em um tempo maior para que o processo de polimerização ocorra de forma satisfatória / Abstract: The objective of this study was to evaluate the effect of the initial storage time in tensile strength of three resin cements bonded to dentin. Sixty bovine teeth were used. The teeth were embedded, polished with silicon carbide papers of 220 and 600 grit and cleaned on ultra-sonic. They were divided in 3 groups of 20 samples each: Group I was fixed with Rely X cement; Group II, Enforce and Group III, Dual Cement. The samples of each group were lutted with the above materials according to each manufacturer's instructions. Half of the samples were tested after 30 minutes, and the other half, after 24 hours. The teeth were embedded to the pairs and positioned in adie stamp, with the surfaces face-to-face to each other and in contact for the adhesive procedure with the resin cement. The resin was photocured for 160 seconds and each specimen was them stored for 30 minutes or 24 hours at 37° C and 100% of relative humidity. With the aid of a metallic die stamp the samples were submitted to the tensile test in machine of universal test INSTRON I (model 4411) at speed of 1 mm/min. The results were submitted to the variance analysis and to Tukey's test (5%). The obtained averages were the following (SD): Group I, 30 minutes = 2,53 (+0,49) MPa; 24 hours = 2,90 (+1,12) MPa; Group II, 30 minutes = 1,65 (+0,46) MPa, 24 hours = 1,94 (+0,43) MPa; Group III, 30 minutes = 4,24 (+1,26) MPa; 24 hours = 6,14 (+01,80) MPa. After the tensile strength test, the surfaces of one of the tested samples were analyzed under SEM in order to determine the prevalence of the fracture pattern in the interface. Based upon the results obtained and discussed on this study can conclude that the mean values of tensile strength for groups I and groups II Obtained with the samples tested on the period of 30 mino did not differ statistically from those tested 24 h., except for group III that differ statistically. The Mean values of tensile strength of groups I, II e III were statistically different among them. Comparing time and values obtained, it is possible to verify a direct proportionality between time and strength, what means that a longer time is necessary to allow the polymerization process to occur in a satisfactory way / Doutorado / Materiais Dentarios / Doutor em Odontologia
50

Influencia do tempo pos-prensagem (imediato e 24 horas) na porosidade, rugosidade, dureza de superficie e resistencia ao impacto de resinas acrilicas

Tanji, Mauricio 22 November 2002 (has links)
Orientadores: Saide Sarckis Domitti, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T20:43:56Z (GMT). No. of bitstreams: 1 Tanji_Mauricio_D.pdf: 4246252 bytes, checksum: 61c4c50d9c7400751bbd6ffc53d3b815 (MD5) Previous issue date: 2002 / Resumo: Este trabalho verificou a influência do tempo pós-prensagem (imediato e 24 horas) sobre porosidade, rugosidade, dureza de superficie e resistência ao impacto de resinas acrílicas termopolimerizávéis: Clássico, QC-20 e Onda-Cryl. Foram obtidos 60 corpos-deprova a partir de matrizes retangulares de alumínio (65xl0 e 64x9 x 3,0 mm), fixados com adesivo instantâneo (Super Bonder, Loctite) em suporte de madeira. As matrizes foram moldadas com silicona por condensação para uso laboratorial (Zetalabor-Labordental Ltda.) e os moldes incluídos em muflas metálicas ou de fibra de vidro. A proporção pó/líquido e mistura, assim como a prensagem das resinas acrilicas foram realizadas de acordo com as instruções dos fabricantes. Após polimerização nos ciclos de água aquecida a 74°C por 9 horas, água em ebulição por 20 minutos e energia de microondas a 1100W por 10 minutos, os corpos-de-prova foram removidos das muflas após esftiamento em temperatura ambiente e submetidos aos processos de acabamento e polimento convencionais. Em seguida, foram submetidos aos ensaios de porosidade, por meio da imersão dos corpos-de-prova em tinta Nankin (Acrilex) por 12 horas, lavagem em água corrente por 10 segundos, sendo posteriormente quantificado e fotografado em área previamente determinada; de rugosidade num rugosímetro Surfcorder SE 1700; dureza, num microdurômetro Shimadzu (Modelo HMV-2000) calibrado com carga de 25 gramas por 10 segundos e o ensaio de resistência ao impacto, numa máquina Otto Wolpert Werke, pelo sistema Charpy. Os resultados submetidos à análise de variância e ao teste de Tukey (5%) mostraram que: 1 - Porosidade: a maior porosidade foi promovida pela resina Onda-Cryl no tempo imediato e a QC-20 no período de 24 horas. Quando o tempo pós-prensagem foi comparado, todas as resinas acrílicas mostraram diferença estatística significativa. 2 - Rugosidade: a rugosidade de superficie não mostrou diferença estatística significativa nos valores entre materiais, quando o fator tempo foi considerado. Quando os tempos foram comparados, somente a resina acrílica Clássico mostrou valores com diferença estatística significativa. 3 - Dureza: no tempo imediato a maior dureza foi mostrada pela resina acrílica Onda-Cryl e a menor pela QC-20, com diferença estatística significativa entre si. No período de 24 horas, a resina acrílica Onda-Cryl apresentou maior valor de dureza, com diferença estatística significativa quando comparado à QC-20. A resina acrílica Clássico apresentou similaridade estatística com ambas. Quando os tempos foram comparados, somente a resina acrílica Onda-Cryl não apresentou diferença estatística significativa. 4 - Resistência ao impacto: não houve diferença estatística significativa nos valores de resistência ao impacto entre os materiais, no tempo imediato. No período de 24 horas, as resinas acrílicas Clássico e Onda-Cryl não mostraram diferença estatística significativa, entretanto ambas foram diferentes estatisticamente da resina acrílica QC-20, esta com menor valor. Quando foram comparados os tempos, somente a resina QC-20 apresentou valor com diferença estatística significativa / Abstract: This study investigated the influence of the post-pressing time (immediate and 24 hours) on the porosity, roughness, hardness of surface and impact strenght variables in Clássico, QC-20 and Onda-Cryl thermo-cured acrylic resins. Sixty specimens were made with a retangular aluminium die (65xl0 and 64x9 x 3,0 mm) attached to a wooden plate with Super Bonder adhesive (Loctite). The die were moulded with Zetalabor condensation silicone (Labordental Ltda.) used for laboratory purposes and the molds were included into metal flasks or reinforced fiberglass flasks. The powder/liquid proportion and mixture, as well as acrylic resin pressing were made according to manufature's instructions. The acrylic resins were cured in heat water (74°C) for 9 hours, boiling water for 20 minutes or by microwave energy with 1100W for 10 minutes. The specimens were removed afier flasks cooling at room temperature and submetted to polishing by conventional procedure. Subsequently, were submetted to: a) porousness test by specimens immersion into Nankin ink (Acrilex) for 12 hours, washed into running water for 10 seconds and thererafter the porous was counted and photographed in. pre-determined areas; b) superficial roughness with Surfcorder SE 1700; c) hardness with Shimadzu microdurometer with load of25 grams by 10 seconds; d) impact strenght test with Charpy system in a Wolpert machine. The results submetted to ANOVA and Tukey's test showed that: 1 - porosity: the best porosity was promoted by Onda-Cryl in the immediate post-pressing time, and the QC-20 in the 24 hours one. When the post-pressing time was compared, alI acrylic resins showed statistical significative difference. 2 - roughness: no statistical significative difference was observed among materials when the post-pressing time was considered. When the post-pressing time was unfoqued, only Clássico acrylic resin showed values with statistical significative difference. 3 - hardness: in the immediate post-pressing the best hardness was showed by the Onda-Cryl and the smallest by QC-20 both with statistical significative difference. In the 24 hours post-pressing, Onda-Cryl showed great hardness values with statistical significative difference when compared to QC-20. Clássico resin showed statistical similarity with both. When the post-pressing time compared, only Onda-Cryl do not presenting statistical significative difference. 4 - impact strength: no statistical significative difference was observed among resins in the immediate post-pressing. In the 24 hours postpressing, the Clássico and Onda-Cryl resins do not showed statistical significative difference, however both were statistically diferent ITomthe QC-20 resin with the smaller value. When the post-pressing time compared, only the QC-20 resin showed value with statistical significative difference / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.0476 seconds