• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • 1
  • Tagged with
  • 50
  • 50
  • 50
  • 48
  • 21
  • 21
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicações da Ressonância Quadrupolar Nuclear em Duas Dimensões / Aplications of the nuclear quadrupole ressonance in two dimensions

Rodríguez, Hernán Joel Cervantes 24 April 1998 (has links)
Neste trabalho implementamos a técnica da ressonância quadrupolar nuclear (RQN) em duas dimensões. O espectro bidimensional é obtido a partir do pseudo-FID usando o estimador autoregressivo. Como o gradiente de campo-elétrico (GCE) no sítio do núcleo é produzido pelas cargas externas ao núcleo e o tensor GCE é simétrico, bastam dois parâmetros para determinar este tensor num sistema de coordenadas dos eixos principais. Estes parâmetros podem ser obtidos a partir do espectro de RQN para todos os núcleos quadrupolares, menos os núcleos com spin 3/2. Usando o espectro bidimensional é possível determinar o parâmetro de assimetria, eta, e consequentemente o outro parâmetro do tensor GCE, mesmo para as amostras policristalinas contendo núcleos com spin 3/2. A oprientação do sistema de coordenadas do tensor GCE no sistema de coordenadas do laboratório não pode ser obtida usando apenas o espectro de RQN. Há vários métodos experimentais que permitem determinar esta orientação relativa. Em todos os casos esta determinação requer um grande esforço experimental com um equipamento muito mais caro que um simples espectrômetro de RQN. Neste trabalho apresentamos um novo método para a deterrminação da orientação do tensor GCE no sistema de coordenadas do laboratório, usando apenas a RQN em duas dimensões e o método da máxima entropia para a deconvolução dos dados experimentais / In this work we implemented the nuclear quadrupole resonance (NQR) in two dimensions. The bidimensional spectrum is obtained from pseudo FID through the auto-regressive estimator. Since the electric field gradient (EFG) at the nucleus site is produced by the external charges and the EFG tensor is symmetric, we need only two parameters to determine this tensor in the coordinate system of principal axis. These parameters can be obtained from the NQR spectra for all the nucleus possessing quadrupole moment, except the one with spin 3/2. Using the bidimensional spectra, it is possible to determine the asymmetry parameter, 7], and consequently the other parameters of the EFG tensor, even in polycrystalline samples containing nucleus with spin 3/2.
2

Aplicações da Ressonância Quadrupolar Nuclear em Duas Dimensões / Aplications of the nuclear quadrupole ressonance in two dimensions

Hernán Joel Cervantes Rodríguez 24 April 1998 (has links)
Neste trabalho implementamos a técnica da ressonância quadrupolar nuclear (RQN) em duas dimensões. O espectro bidimensional é obtido a partir do pseudo-FID usando o estimador autoregressivo. Como o gradiente de campo-elétrico (GCE) no sítio do núcleo é produzido pelas cargas externas ao núcleo e o tensor GCE é simétrico, bastam dois parâmetros para determinar este tensor num sistema de coordenadas dos eixos principais. Estes parâmetros podem ser obtidos a partir do espectro de RQN para todos os núcleos quadrupolares, menos os núcleos com spin 3/2. Usando o espectro bidimensional é possível determinar o parâmetro de assimetria, eta, e consequentemente o outro parâmetro do tensor GCE, mesmo para as amostras policristalinas contendo núcleos com spin 3/2. A oprientação do sistema de coordenadas do tensor GCE no sistema de coordenadas do laboratório não pode ser obtida usando apenas o espectro de RQN. Há vários métodos experimentais que permitem determinar esta orientação relativa. Em todos os casos esta determinação requer um grande esforço experimental com um equipamento muito mais caro que um simples espectrômetro de RQN. Neste trabalho apresentamos um novo método para a deterrminação da orientação do tensor GCE no sistema de coordenadas do laboratório, usando apenas a RQN em duas dimensões e o método da máxima entropia para a deconvolução dos dados experimentais / In this work we implemented the nuclear quadrupole resonance (NQR) in two dimensions. The bidimensional spectrum is obtained from pseudo FID through the auto-regressive estimator. Since the electric field gradient (EFG) at the nucleus site is produced by the external charges and the EFG tensor is symmetric, we need only two parameters to determine this tensor in the coordinate system of principal axis. These parameters can be obtained from the NQR spectra for all the nucleus possessing quadrupole moment, except the one with spin 3/2. Using the bidimensional spectra, it is possible to determine the asymmetry parameter, 7], and consequently the other parameters of the EFG tensor, even in polycrystalline samples containing nucleus with spin 3/2.
3

Estudo das caracteristicas morfologicas do lobo da insula em pacientes portadores de epilepsia do lobo temporal medial / Study of the morphologie characteristics of the insula lobe in patients with epilepsy of the medial temporal lobe

Chaddad Neto, Feres Eduardo Aparecido 21 February 2006 (has links)
Orientador: Evandro Pinto da Luz de Oliveira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-06T17:08:11Z (GMT). No. of bitstreams: 1 ChaddadNeto_FeresEduardoAparecido_M.pdf: 5740692 bytes, checksum: 41706f7c50d8c3c6567a1c592112c6e0 (MD5) Previous issue date: 2006 / Resumo: A epilepsia do lobo temporal medial é o subtipo mais freqüente de epilepsia do lobo temporal e é causada, principalmente, pela esclerose medial temporal (EMT). A EMT é caracterizada pela esclerose hipocampal e diferentes graus de acometimento das estruturas vizinhas como amídala, giro parahipocampal e córtex entorrinal. O lobo da ínsula é uma estrutura neocortical e se constitui no envoltório externo da região dos núcleos da base, apresentando várias conexões com o lobo temporal e com o sistema límbico. O estudo apresenta como objetivo analisar o lobo da ínsula, descrevendo se há alteração do mesmo pelo método Neuroline e E-Film. O estudo avaliou 40 indivíduos com EMT e 40 do grupo controle. Pelo método Neuroline 45% eram homens e 55% eram mulheres com EMT- Pelo método E-Fim a distribuição foi de 50% entre os sexos do grupo esclerose. Os casos foram avaliados por um método para as medidas da insula (E-Film) e outro método para o cálculo do volume (Neuroline). Não houve diferença estatística de alteração de volume e das medidas do lobo da ínsula nos pacientes portadores de EMT. O estudo não demonstrou alteração morfológica da ínsula quando comparado os dois grupos / Abstract: The temporal medial epilepsy is the most common type of temporal lobe epilepsy caused, specially, by temporal medial sclerosis (TMS). The TMS is characterized by hippocampal sclerosis and by distinghished grades of injury near to other neurological structures such as: amygdaloid nucleus, parahippocampal girus and entorhinal region. The insula's lobe is neocortical structure which is formed by an external wrapped of the basal ganglion, it's usually presenting some connections with temporal lobe and with limbic system. The aim's study was analyzing the insula's lobe if there are alteration with patient's carriers of TMS by Neuroline's and E-Film's methods. The study analyzed 40 patients with TMS and 40 people from the control cluster. All cases were evaluated by two methods: measurement of insula's cortex (E-Film) and evaluation of the insula's volume (Neuroline). By Neuroline's method 45 per cent were male and 55 per cent were female. By E-Film's method there are distribution with half of the percentage for both genders. There was no statistical difference between the insula's volume and insula's measurement for the two groups. This study did not show the insula's morphological variation when these two groups were compared / Mestrado / Neurologia / Mestre em Ciências Médicas
4

Espectroscopia de alta resolução em sólidos por ressonância magnétoca nuclear. / High resolution spectroscopy in solids for nuclear resonace

Bonagamba, Tito Jose 25 July 1991 (has links)
Este trabalho descreve técnicas de espectroscopia de alta resolução em sólidos por Ressonância Magnética Nuclear (RMN), o projeto de construção de um espectrômetro para este fim e sua avaliação experimental com a utilização deste equipamento na caracterização de amostras sólidas. O espectrômetro de alta resolução em sólidos por RMN desenvolvido, permite a utilização de técnicas de dupla ressonância, múltiplos pulsos e rotação da amostra em tomo do ângulo mágico e pode também ser utilizado para líquidos. A máxima freqüência de rotação para MAS é da ordem de 5KHz e as seqüências de dupla ressonância podem ser utilizadas pala quaisquer pares de núcleos atômicos. Os experimentos podem ser realizados com variação de temperatura de -120&#176C a + 160&#176C e o equipamento é totalmente controlado por um microcomputador Macintosh IIci. / This work describes the nuclear magnetic resonance (NMR) techniques for High Resolution Spectroscopy in Solids. Also, the construction project of a partially \"home made\" spectrometer and its applications in the characterization of solid samples are shown in detail. Our high resolution spectrometer is implemented with the double resonance multiple pulses sequences and magic angle spinning (MAS) and can be used with solid and liquid samples. The maximum spinning frequency for the MAS experiment is in excess of 5KHz, the double resonance sequences can be performed with any type of nucleus, in the variable temperature operating range with nitrogen gas: -120&#176C to +160&#176C, and is fully controlled by a Macintosh IIci microcomputer.
5

Software para orientação de neurocirurgia guiada por um transdutor espacial 3D / Software for neurosurgery orientation tracked by a 3D spacial transducer.

Perini, Ana Paula 03 August 2007 (has links)
Neurocirurgia guiada por imagem permite ao neurocirurgião navegar dentro do cérebro do paciente, usando imagens pré-operatórias como orientação, através do uso de sistemas de rastreamento, durante o procedimento cirúrgico. Muitos sistemas desenvolvidos para neurocirurgia guiada por imagem, empregam imagens pré-operatórias para fornecer orientação ao cirurgião, durante o procedimento cirúrgico. Seguindo um procedimento de calibração, a posição tridimensional e orientação dos instrumentos cirúrgicos podem ser transmitidas ao computador. Estas informações espaciais são usadas para acessar a região de interesse nas imagens pré-operatórias com a finalidade de apresentá-las ao cirurgião durante o procedimento. Contudo, quando ocorre a craniotomia, o movimento dos tecidos do cérebro pode ser fonte significativa de erro nestes sistemas. A arquitetura implementada neste trabalho visa o desenvolvimento de um sistema que permite planejamento e orientação cirúrgica. Para orientação cirúrgica foi desenvolvido um software que permite extrair fatias do volume de imagens de ressonância magnética (IRM), com orientação fornecida por um transdutor de posição magnético (Polhemus®). As fatias extraídas serão, futuramente, correlacionadas com imagens de ultra-som (IUS) intra-operatórias para detectar e corrigir a deformação do tecido cerebral durante a cirurgia. A ferramenta para navegação pré-cirúrgica foi desenvolvida para fornecer três fatias ortogonais obtidas através do volume de imagens. Na metodologia usada para a implementação do software, foi utilizada a linguagem de programação Python e a biblioteca gráfica Visualization Toolkit (VTK). Os resultados mostraram que o programa de planejamento pré-cirúrgico, gerou uma alta resolução na visualização dos planos ortogonais e oblíquos das IRM, além de ser rápido e interativo. O programa de extrair fatias do volume de IRM permitiu a aplicação de transformações ao volume, com base nos valores de coordenadas fornecidos pelo transdutor de posição. / Image guided neurosurgery enables the neurosurgeon to navigate inside the patient\'s brain using pre-operative images as a guide and a tracking system, during surgical procedure. Many image guided neurosurgery implementations employ pre-operative images as a guide to the surgeons throughout surgical procedure. Following a calibration procedure, three-dimensional position and orientation of surgical instruments may be transmitted to computer. The spatial information is used to access an interest region, in the pre-operative images, displaying them to the neurosurgeon during the surgical procedure. However, when a craniotomy is involved, movements of brain tissue can be a significant source of error in these systems. The architecture implemented in this work intends the development of a system to surgical planning and orientation. For surgical orientation, the software developed allows the extraction of slices from the volume of the magnetic resonance images (MRI) with orientation supplied by a magnetic position sensor (Polhemus®). In the future, the extracted slices will be correlated with intra-operative ultrasound images to detect and to correct the deformation of brain tissue during the surgery. Also, a tool for pre-operative navigation was developed, providing three orthogonal planes through the image volume. In the methodology used for the software implementation, the Python programming language and the Visualization Toolkit (VTK) graphics library were used. The results showed that the program of pre-operative navigation had high resolution in the visualization of orthogonal and oblique MRI planes. Furthermore, it was fast and interactive. The program to extract slices of the MRI volume allowed the application of transformations in the volume, using coordinates supplied by the position sensor.
6

Endometriose pélvica: aspectos à ressonância magnética e correlação com laparoscopia e anatomia patológica / Pelvic endometriosis: correlation among magnetic resonance imaging, laparoscopy and pathological findings

Chamié, Luciana Pardini 19 December 2008 (has links)
Introdução: A endometriose é uma doença ginecológica comum, caracterizada pela presença de tecido endometrial glandular e/ou estromal fora dos limites uterinos. Acomete principalmente as mulheres na idade reprodutiva e representa causa freqüente de dor pélvica crônica e infertilidade. O diagnóstico representa um dos maiores problemas no contexto clínico desta doença, sendo o mapeamento dos focos de extrema importância na escolha da modalidade terapêutica e no prognóstico da paciente. Este estudo teve por finalidade avaliar a capacidade da ressonância magnética (RM) da pelve para o diagnóstico pré-operatório da endometriose nos ovários, região retrocervical, reto-sigmóide, bexiga, ureteres e vagina em correlação aos achados de laparoscopia e de anatomia patológica, além de descrever os aspectos de imagem da doença nestes sítios à RM. Métodos: O presente estudo, transversal, observacional e prospectivo, efetuado em 92 pacientes do sexo feminino com suspeita clínica de endometriose profunda, foi realizado de novembro de 2005 a julho de 2007. As pacientes foram procedentes do Serviço de Ambulatório de Endometriose do Departamento de Ginecologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP), e tinham idades entre 20 e 52 anos (média de 33 anos). As imagens de RM foram analisadas independentemente por dois radiologistas experientes e o diagnóstico estabelecido através de consenso entre eles. Endometriose foi diagnosticada quando foram identificados cistos ovarianos com elevado sinal em T1 e baixo sinal em T2 (shading) ou nódulos peritoniais de baixo sinal em T2 localizados na região retrocervical, reto-sigmóide, bexiga, ureteres e vagina. Os achados da RM foram comparados com aqueles obtidos na laparoscopia e anatomia patológica. Foram avaliados os valores de sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia da RM para o diagnóstico da endometriose. Resultados: Endometriose ovariana e profunda foi confirmada através da anatomia patológica em 77 das 92 pacientes inclusas neste estudo. Em 15 pacientes foram observadas somente lesões peritoniais superficiais. A sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia da RM para o diagnóstico de endometriose nos diversos sítios avaliados foi: ovários, 100%, 88,9%, 93,3%, 100% e 95,7%; região retrocervical, 89,4%, 92,3%, 96,7%, 77,4% e 90,2%; reto-sigmóide, 86%, 92,9%, 93,5%, 84,8% e 89,1%; bexiga, 23,1%, 100%, 100%, 88,8% e 89,1%; ureteres, 50%, 100%, 100%, 95,5% e 95,7% e vagina, 72,7%, 100%, 100%, 96,4% e 96,7%. Conclusão: A RM demonstrou elevada acurácia no diagnóstico pré-operatório da endometriose nos ovários, região retrocervical, reto-sigmóide, bexiga, ureteres e vagina. Os achados mais representativos da doença à RM são os cistos ovarianos de conteúdo hemorrágico com elevado sinal em T1 e baixo sinal em T2 (shading) e os nódulos peritoniais de baixo sinal em T2 em localizações específicas / Introduction: Endometriosis is a prevalent gynecological disease characterized by the presence of endometrial glandular and/or stromal tissue outside the uterine boundaries. This disorder causes infertility and it is the most common cause of chronic pelvic pain affecting women in the reproductive age. Appropriate clinical diagnosis and pelvic imaging information regarding the spread and the infiltration of the lesions remains a major diagnostic challenge. The objectives of this study were to describe magnetic resonance imaging (MRI) aspects of endometriosis in the most commonly affect sites and to evaluate the accuracy of the pre-operative MRI findings with those obtained at surgery and pathology. Methods: This prospective, transversal and observational study included 92 women with clinical suspicion of deeply infiltrative endometriosis and was carried out between November 2005 and July 2007. Women aged 20 and 52 (mean 33) years old were followed at the Serviço de Ambulatório de Endometriose do Departamento de Ginecologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP). Two experienced radiologists evaluated the magnetic resonance (MR) images independently and provided consensus reading. Endometriosis was defined as ovarian cysts with high signal intensity on T1-weighted images and low signal intensity on T2 (shading) and nodule or masses that appeared as hypointense areas on T2-weighted images in the following locations: retrocervical space, rectosigmoid, bladder, ureters and vagina. MR findings were compared with those obtained at laparoscopy and pathology. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of MRI for prediction of deep pelvic endometriosis were assessed. Results: Endometriomas and deep infiltrative endometriosis were confirmed at histopathology in 77 (83.7%) out of 92 patients. In 15 women there were only superficial peritoneal lesions. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of MRI for prediction of deep pelvic endometriosis in the specific sites were: endometriomas (100%, 88.9%, 93.3%, 100%, 95.7%); retrocervical (89.4%, 92.3%, 96.7%, 77.4%, 90.2%); rectosigmoid (86.0%, 92.9%, 93.5%, 84.8%, 89.1%); bladder (23.1%, 100%, 100%, 88.8%, 89.1%); ureters (50.0%, 100%, 100%, 95.5%, 95.7%) and vagina (72.7%, 100%, 100%, 96.4%, 96.7%).Conclusions: Magnetic resonance imaging demonstrates high accuracy in prediction of deep pelvic endometriosis in the ovaries, retrocervical region, rectosigmoid, bladder, ureters and vagina. The most characteristic findings representatives of deep pelvic endometriosis are ovarian cysts which appeared with elevated signal in T1 and low signal in T2 (shading) and peritoneal nodes situated in the specifically described locations outlined by low signal in T2
7

Estudo da microestrutura e dinâmica molecular do Poly(3-(2\'-ethylhexyl)thiophene)(P3EHT) via ressonância magnética nuclear / Study of the microstructure and molecular dynamics of Poly(3-(2\'-ethylhexyl)thiophene)(P3EHT) by nuclear magnetic resonance

Cunha, Giovanni Paro da 18 April 2016 (has links)
O estudo da microestrutura e dinâmica molecular de polímeros conjugados é de grande importância para o entendimento das propriedades físicas desta classe de materiais. No presente trabalho utilizou-se técnicas de ressonância magnética nuclear em baixo e alto campo para elucidar os processos de dinâmica molecular e cristalização do polímero Poly(3-(2’-ethylhexyl)thiophene) - P3EHT. O P3EHT é um polímero modelo para tal estudo, pois apresenta temperatura de fusão bem inferior a sua temperatura de degradação. Esta característica permite acompanhar os processos de cristalização in situ utilizando RMN. Além disso, sua similaridade ao já popular P3HT o torna um importante candidato a camada ativa em dispositivos eletrônicos orgânicos. O completo assinalamento do espectro de 13C para o P3EHT foi realizado utilizando as técnicas de defasamento dipolar e HETCOR. Os processos de dinâmica molecular, por sua vez, foram sondados utilizando DIPSHIFT. Observou-se um gradiente de mobilidade na cadeia lateral do polímero. Além disso, os baixos valores de parametros de ordem obtidos em comparação a experimentos similares realizados no P3HT na literatura indicam um aparente aumento no volume livre entre cadeias consecutivas na fase cristalina. Isso indica que a presença do grupo etil adicional no P3EHT causa um completo rearranjo das moléculas e dificulta seu empacotamento. Constatou-se ainda pouca variação das curvas de DIPSHIFT para os carbonos da cadeia lateral como função do método de excitação utilizado, o que aponta para um polímero que apresenta cadeia lateral móvel mesmo em sua fase cristalina. Os dados de dinâmica molecular foram corroborados por medidas de T1, T1ρ e TCH. Utilizando filtros dipolares em baixo campo observou-se três temperaturas de transição para o P3EHT: 250 K, 325 K e 350 K. A cristalização desse material é um processo lento. Verificou-se que o mesmo pode se estender por até até 24h a temperatura ambiente. Mudanças no espectro de 13C utilizando CPMAS em alto campo indicam um ordenamento dos anéis tiofeno (empacotamento π – π) como o principal processo de cristalização para o P3EHT. / The study of the microstructure and molecular mobility of conjugated polymers is of the utmost importance for the understanding of the physical properties of this class of materials. In the current work we employed nuclear magnetic resonance techniques to shed light into the processes of molecular dynamics and crystallization of the polymer Poly(3-(2’-ethylhexyl)thiophene) - P3EHT. The P3EHT is a model polymer for such a study since it displays a melting temperature well below it’s degradation temperature, this allowed us to probe the crystallization process in situ using NMR. Furthermore it’s similarity to the already popular P3HT makes it a good candidate to active layer in organic electronic devices. A complete assignment of the 13C spectrum was achieved for the P3EHT, using the dipolar dephasing and HETCOR techniques. The molecular movements were probed by DIPSHIFT. We observed a mobility gradient along the side-chain of the material. The low values obtained for the order parameter in comparison to similar experiments done on the P3HT on the literature indicate a apparent increase in the free volume between consecutive chains in the crystalline phase, this is a strong indicative that the addition of the ethyl group to the repetitive unit strongly rearranges the molecules, difficulting packing. Moreover the depth of the DIPSHIFT curves for the side-chain carbons at half the rotor period don’t seem to be a function of the excitation method employed, this points to a polymer that is throughout mobile, i.e. that has carbons with a high degree of mobility even in it’s crystalline phase. This results were corroborated by measurements of T1, T1ρ e TCH. Employing dipolar filters at low field three transition temperatures were observed: 250 K, 325 K and 350K. The crystallization of the P3EHT is a slow process. We found that it took up to 24h for the material to fully recrystallize from the melting at room temperature. Changes in the 13C CPMAS spectra at high fields indicate a ordering of the thiophene rings (π – π stacking) as the primary method for the crystallization in the P3EHT.
8

Software para orientação de neurocirurgia guiada por um transdutor espacial 3D / Software for neurosurgery orientation tracked by a 3D spacial transducer.

Ana Paula Perini 03 August 2007 (has links)
Neurocirurgia guiada por imagem permite ao neurocirurgião navegar dentro do cérebro do paciente, usando imagens pré-operatórias como orientação, através do uso de sistemas de rastreamento, durante o procedimento cirúrgico. Muitos sistemas desenvolvidos para neurocirurgia guiada por imagem, empregam imagens pré-operatórias para fornecer orientação ao cirurgião, durante o procedimento cirúrgico. Seguindo um procedimento de calibração, a posição tridimensional e orientação dos instrumentos cirúrgicos podem ser transmitidas ao computador. Estas informações espaciais são usadas para acessar a região de interesse nas imagens pré-operatórias com a finalidade de apresentá-las ao cirurgião durante o procedimento. Contudo, quando ocorre a craniotomia, o movimento dos tecidos do cérebro pode ser fonte significativa de erro nestes sistemas. A arquitetura implementada neste trabalho visa o desenvolvimento de um sistema que permite planejamento e orientação cirúrgica. Para orientação cirúrgica foi desenvolvido um software que permite extrair fatias do volume de imagens de ressonância magnética (IRM), com orientação fornecida por um transdutor de posição magnético (Polhemus®). As fatias extraídas serão, futuramente, correlacionadas com imagens de ultra-som (IUS) intra-operatórias para detectar e corrigir a deformação do tecido cerebral durante a cirurgia. A ferramenta para navegação pré-cirúrgica foi desenvolvida para fornecer três fatias ortogonais obtidas através do volume de imagens. Na metodologia usada para a implementação do software, foi utilizada a linguagem de programação Python e a biblioteca gráfica Visualization Toolkit (VTK). Os resultados mostraram que o programa de planejamento pré-cirúrgico, gerou uma alta resolução na visualização dos planos ortogonais e oblíquos das IRM, além de ser rápido e interativo. O programa de extrair fatias do volume de IRM permitiu a aplicação de transformações ao volume, com base nos valores de coordenadas fornecidos pelo transdutor de posição. / Image guided neurosurgery enables the neurosurgeon to navigate inside the patient\'s brain using pre-operative images as a guide and a tracking system, during surgical procedure. Many image guided neurosurgery implementations employ pre-operative images as a guide to the surgeons throughout surgical procedure. Following a calibration procedure, three-dimensional position and orientation of surgical instruments may be transmitted to computer. The spatial information is used to access an interest region, in the pre-operative images, displaying them to the neurosurgeon during the surgical procedure. However, when a craniotomy is involved, movements of brain tissue can be a significant source of error in these systems. The architecture implemented in this work intends the development of a system to surgical planning and orientation. For surgical orientation, the software developed allows the extraction of slices from the volume of the magnetic resonance images (MRI) with orientation supplied by a magnetic position sensor (Polhemus®). In the future, the extracted slices will be correlated with intra-operative ultrasound images to detect and to correct the deformation of brain tissue during the surgery. Also, a tool for pre-operative navigation was developed, providing three orthogonal planes through the image volume. In the methodology used for the software implementation, the Python programming language and the Visualization Toolkit (VTK) graphics library were used. The results showed that the program of pre-operative navigation had high resolution in the visualization of orthogonal and oblique MRI planes. Furthermore, it was fast and interactive. The program to extract slices of the MRI volume allowed the application of transformations in the volume, using coordinates supplied by the position sensor.
9

Avaliação da geração de palavras, em indivíduos com doença de Parkinson, através de ressonância magnética funcional / Word generation in Parkinson\'s disease a functional magnetic resonance study

Maia, Fernanda Martins 09 September 2009 (has links)
INTRODUÇÃO: As alterações cognitivas na doença de Parkinson (DP) têm sido mais estudadas nos últimos anos, porém alterações de linguagem, embora detectadas clinicamente, permanecem pouco exploradas. Neste estudo, avalia-se a capacidade de pacientes com DP de gerar palavras, durante paradigma de ressonância magnética funcional (RMf), comparandose com voluntários sadios. MÉTODOS: Neste estudo, foram incluídos 17 pacientes com doença de Parkinson, em seguimento no ambulatório de Distúrbios do Movimento do Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo e 20 voluntários normais, pareados quanto à idade e escolaridade. Todos foram submetidos à avaliação neurológica e neuropsicológica. Cada indivíduo realizou dois exames de RMf, sendo utilizado o paradigma de geração de palavras, constando de 70 letras cada, durante os quais dados comportamentais foram coletados. As imagens foram analisadas com testes não paramétricos e mapas de correlação entre os resultados de RMf e dados comportamentais (percentagem de acertos) foram construídos. RESULTADOS: Os grupos apresentavam perfis neuropsicológicos semelhantes, com diferenças somente em testes que envolviam velocidade motora. Nos indivíduos com DP, observou-se ativação das regiões frontal dorsolateral esquerda, giro do cíngulo anterior, área motora suplementar esquerda e do cerebelo à direita durante a geração de palavras, à semelhança do grupo controle. Na comparação entre grupos, notou-se maior resposta hemodinâmica nos pacientes com DP, em relação aos controles, em áreas do córtex frontal dorsolateral esquerdo. Observouse, ainda, no grupo com DP, menor atividade na porção anterior do cíngulo e área motora suplementar esquerda. Na análise comportamental, incluindo a classificação dos erros, não houve diferenças entre os grupos. Para explicar esses resultados, especula-se que as diferenças nas áreas subcorticais possam estar relacionadas com o aumento da atividade no córtex frontal dorsolateral, uma vez que a degeneração das vias mesolímbicas é descrita na DP, associada com disfunção no circuito dos núcleos da base, provavelmente envolvendo as alças do cíngulo e dorsolateral. Isso significaria uma manobra compensatória, garantindo um desempenho funcional normal nos pacientes com DP. CONCLUSÃO: Ativação do córtex frontal dorsolateral esquerdo, giro do cíngulo anterior, área motora suplementar esquerda e do cerebelo à direita foram observadas nos pacientes com DP durante paradigma de geração de palavras. Maior ativação do córtex frontal dorsolateral esquerdo ocorre nos pacientes com DP e menor atividade foi observada no cíngulo anterior e área motora suplementar esquerda, quando comparados a voluntários normais, durante paradigma de geração de palavras. / Cognitive disturbances have been studied in patients with Parkinson´s disease (PD) in the last years but language dysfunction, although observed in clinical practice, are just now being explored. In this study, we investigate PD patients ability to generate words using a functional magnetic resonance (fRMI) paradigm and compare these areas with healthy volunteers. We selected 17 PD patients from the Movement Disorders Clinics of Hospital das Clinicas, Universidade de São Paulo and 20 healthy volunteers, matched for age and years of formal education. Both groups were evaluated from neurological and neurophsychological perspective and showed similar profiles, with differences only in tests that involved motor speed. Each subject was scanned twice using an overt-speech block design fRMI paradigm with visual presentation of 70 stimuli during which behavioral data were collected. Images were analyzed using a non-parametric approach, and correlation maps between fRMI results and behavioral data (percentage of correct responses) were produced. PD patients showed activity on the left dorsolateral frontal cortex, anterior cingulate gyrus, motor supplementary areas and right cerebellum during the word generation paradigm, similar to the healthy volunteers group. PD patients had increased hemodynamic response in the left dorsolateral frontal cortex and a reduction was found at anterior cingulated gyrus and motor supplementary area compared to healthy volunteers. Behavioral analyses (including error classification) did not show any differences between groups. We speculate that the difference found in subcortical areas may be related to the increment observed in the frontal dorsolateral cortex, since degeneration of mesolimbic dopaminergic pathways is described in PD associated with dysfunction on basal ganglia circuitry, especially involving the cingulated and dorsolateral loop. A possible mechanism involves a compensatory maneuver, in a way to maintain a normal functional performance in PD patients. In conclusion, we observed the activation on the left dorsolateral frontal cortex, anterior cingulated gyrus, motor supplementary areas and right cerebellum during the word generation paradigm in PD patients. These patients had greater cortical activity on the left dorsolateral frontal cortex and less activity on the anterior portion of the cingulated gyrus and motor supplementary area when compared to normal controls.
10

Desenvolvimento de algoritmo computacional para volumetria de estruturas cerebrais em imagens de ressonância magnética nuclear / not available

Rodrigues, Luciene Cavalcanti 12 August 2002 (has links)
Este projeto apresenta a pesquisa e projeto de um algoritmo computacional para realizar a avaliação volumétrica de estruturas cerebrais, a partir de imagens da Ressonância Magnética Nuclear (RMN). O algoritmo possibilita a seleção das estruturas a serem avaliadas nos vários planos do exame e, então realiza a integração das áreas calculadas para cada corte de modo a obter o volume de cada estrutura selecionada. O contorno da região de interesse em cada corte é definido pelo médico especialista de forma interativa, através da combinação de \"tresholding\" com uma função de edição manual de contorno. Os resultados obtidos indicaram a potencialidade de uso do algoritmo para o auxílio ao diagnóstico e estadiamento clínico de doenças como Mal de Alzheimer e Epilepsia do lobo temporal. O algoritmo foi considerado suficientemente preciso pelos especialistas que o testaram, mantendo a variação das medidas de volume abaixo de 1,5 mm3. O tempo médio para a realização de um estudo completo foi de aproximadamente 25 minutos. / This project presents the development of a computational algorithm focused on the volumetric measurement of cerebral structures in Nuclear Magnetic Resonance Images. The algorithm allows the selection of structures to be analysed on each exam slices and realizes the integration of calculated areas for each slice to get a volumetric measurement of each selected structure. The edge of interest region in each slice must be interatively defined for a specialist, based on a combination of thresholding with a manual segmentation function. The results points to the potenciality of the algorithm aplication to aid the diagnosis of diseases as Alzheimer\'s disease and temporal lobe epilepsy.

Page generated in 0.0752 seconds