• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 1
  • Tagged with
  • 8
  • 7
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

\"Espectrometria de raios X em mamografia aplicada à proteção radiológica\" / X ray spectroscopy in mammography applied to radiological protection

Künzel, Roseli 07 July 2006 (has links)
Neste trabalho foram efetuadas medições de espectros de raios X espalhados por um objeto simulador de mama em uma unidade de mamografia clínica para as combinações alvo/filtro Mo/Mo, Mo/Rh e W/Rh e tensões de aceleração do tubo de 25 e 30 kV. Os espectros de raios X foram registrados por um detector Cd0.9Zn0.1Te (CZT) para ângulos de espalhamento entre 30 e 165o. Os métodos de medição e correção dos espectros experimentais foram avaliados a partir da comparação entre os valores de kerma no ar e camada semi-redutora calculados a partir dos espectros de raios X corrigidos com aqueles obtidos a partir de medições efetuadas com uma câmara de ionização em uma unidade de mamografia não-clínica. As formas dos espectros de raios X experimentais obtidos nesta unidade não-clínica, devidamente corrigidos, foram comparadas aos espectros de raios X simulados utilizando-se modelos semi-empíricos e de Monte Carlo publicados na literatura. Os espectros de raios X relativos aos feixes primários no equipamento clínico foram simulados utilizando-se modelos semi-empíricos normalizados para os valores de kerma no ar obtidos a partir de medições efetuadas com uma câmara de ionização. Os espectros de raios X espalhados obtidos no sistema de raios X clínico foram caracterizados a partir da determinação da camada semi-redutora e da energia média do espectro. Valores de kerma no ar, equivalente de dose ambiente, dose efetiva e fração de espalhamento foram calculados a partir dos espectros de raios X experimentais corrigidos para as três combinações alvo/filtro disponíveis no equipamento clínico. Coeficientes de conversão médio de kerma no ar para equivalente de dose ambiente e de kerma no ar para dose efetiva também foram calculados para os espectros de raios X espalhados produzidos pelas combinações alvo/filtro Mo/Mo, Mo/Rh e W/Rh. Os resultados obtidos neste trabalho mostram que para os espectros de raios X espalhados o equivalente de dose ambiente fornece uma superestimativa do valor da dose efetiva por um fator de aproximadamente 5 na região de energia utilizada em mamografia. Os resultados também mostram que os valores de fração de espalhamento obtidos para a combinação W/Rh são maiores que aqueles obtidos para as combinações Mo/Mo e Mo/Rh. Os resultados obtidos neste trabalho podem ser usados para avaliar a concordância com os limites de dose estabelecidos por normas regulamentadoras próximos a uma unidade clínica de mamografia e no cálculo de barreiras protetoras mais realísticas em mamografia. A influência de diferentes combinações alvo/filtro na espessura de uma barreira protetora em uma unidade de mamografia clínica também pode ser avaliada. / In this work measurements of specters of rays X had been effected spread by a simulator object of breast in a unit of clinical mamografia for the combinations white/filter Me /Me, Me /Rh and W/Rh and tensions of acceleration of the 30 pipe of 25 and kV
2

\"Espectrometria de raios X em mamografia aplicada à proteção radiológica\" / X ray spectroscopy in mammography applied to radiological protection

Roseli Künzel 07 July 2006 (has links)
Neste trabalho foram efetuadas medições de espectros de raios X espalhados por um objeto simulador de mama em uma unidade de mamografia clínica para as combinações alvo/filtro Mo/Mo, Mo/Rh e W/Rh e tensões de aceleração do tubo de 25 e 30 kV. Os espectros de raios X foram registrados por um detector Cd0.9Zn0.1Te (CZT) para ângulos de espalhamento entre 30 e 165o. Os métodos de medição e correção dos espectros experimentais foram avaliados a partir da comparação entre os valores de kerma no ar e camada semi-redutora calculados a partir dos espectros de raios X corrigidos com aqueles obtidos a partir de medições efetuadas com uma câmara de ionização em uma unidade de mamografia não-clínica. As formas dos espectros de raios X experimentais obtidos nesta unidade não-clínica, devidamente corrigidos, foram comparadas aos espectros de raios X simulados utilizando-se modelos semi-empíricos e de Monte Carlo publicados na literatura. Os espectros de raios X relativos aos feixes primários no equipamento clínico foram simulados utilizando-se modelos semi-empíricos normalizados para os valores de kerma no ar obtidos a partir de medições efetuadas com uma câmara de ionização. Os espectros de raios X espalhados obtidos no sistema de raios X clínico foram caracterizados a partir da determinação da camada semi-redutora e da energia média do espectro. Valores de kerma no ar, equivalente de dose ambiente, dose efetiva e fração de espalhamento foram calculados a partir dos espectros de raios X experimentais corrigidos para as três combinações alvo/filtro disponíveis no equipamento clínico. Coeficientes de conversão médio de kerma no ar para equivalente de dose ambiente e de kerma no ar para dose efetiva também foram calculados para os espectros de raios X espalhados produzidos pelas combinações alvo/filtro Mo/Mo, Mo/Rh e W/Rh. Os resultados obtidos neste trabalho mostram que para os espectros de raios X espalhados o equivalente de dose ambiente fornece uma superestimativa do valor da dose efetiva por um fator de aproximadamente 5 na região de energia utilizada em mamografia. Os resultados também mostram que os valores de fração de espalhamento obtidos para a combinação W/Rh são maiores que aqueles obtidos para as combinações Mo/Mo e Mo/Rh. Os resultados obtidos neste trabalho podem ser usados para avaliar a concordância com os limites de dose estabelecidos por normas regulamentadoras próximos a uma unidade clínica de mamografia e no cálculo de barreiras protetoras mais realísticas em mamografia. A influência de diferentes combinações alvo/filtro na espessura de uma barreira protetora em uma unidade de mamografia clínica também pode ser avaliada. / In this work measurements of specters of rays X had been effected spread by a simulator object of breast in a unit of clinical mamografia for the combinations white/filter Me /Me, Me /Rh and W/Rh and tensions of acceleration of the 30 pipe of 25 and kV
3

Aplicação de câmaras de ionização especiais para controle de qualidade em mamografia / Application of special ionization chambers for quality control in mammography

Honda, Cristiane Jordão de Carvalho 19 August 2015 (has links)
A mamografia é um exame realizado no mamógrafo, que utiliza raios X para obter imagens da anatomia interna da mama. Para que esta imagem seja capaz de fornecer um diagnóstico correto, é necessário que os equipamentos passem constantemente por programas de controle de qualidade para que se possa garantir que as pacientes submetidas a este exame não estejam recebendo dose além da necessária, evitando-se assim possíveis efeitos biológicos indesejados. As câmaras de ionização são detectores muito utilizados para se realizar o controle de qualidade de equipamentos que utilizam radiação, como os mamógrafos. No presente trabalho foram utilizadas quatro câmaras de ionização desenvolvidas no Laboratório de Calibração de Instrumentos do IPEN LCI/IPEN, que foram submetidas a testes de caracterização em feixes padrões de radiação X do LCI. Elas apresentaram resultados satisfatórios, dentro dos limites estabelecidos pelas normas nacionais e internacionais. Como aplicação, estas câmaras de ionização foram utilizadas para testes de controle de qualidade em quatro mamógrafos clínicos de diferentes instituições quanto à repetibilidade e linearidade da taxa de kerma no ar. Os resultados obtidos nestes testes encontram-se dentro dos limites recomendados pelas normas nacionais e internacionais. / Mammography is an examination in mammography, which uses X-rays to obtain images of the internal anatomy of the breast. To provide a correct diagnosis, it is necessary that the equipment constantly undergo quality control programs to ensure that patients submitted to this examination do not receive more than the necessary dose, thus avoiding unwanted possible biological effects. The ionization chambers are widely used detectors to perform the quality control program of equipment with radiation, as mammographers. In the present study, four different special ionization chambers, developed at the Calibration Laboratory of Instruments of IPEN - LCI / IPEN, were submitted to the characterization tests in standard X radiation beams at the LCI. The results were satisfactory, within the limits estabilished by national and international standards. As an application, the ionization chambers were used for quality control tests in four mammography clinics from different institutions, as the repeatability and linearity of the air kerma rate. The results obtained in these tests were within the limits recommended by national and international standards.
4

Aplicação de câmaras de ionização especiais para controle de qualidade em mamografia / Application of special ionization chambers for quality control in mammography

Cristiane Jordão de Carvalho Honda 19 August 2015 (has links)
A mamografia é um exame realizado no mamógrafo, que utiliza raios X para obter imagens da anatomia interna da mama. Para que esta imagem seja capaz de fornecer um diagnóstico correto, é necessário que os equipamentos passem constantemente por programas de controle de qualidade para que se possa garantir que as pacientes submetidas a este exame não estejam recebendo dose além da necessária, evitando-se assim possíveis efeitos biológicos indesejados. As câmaras de ionização são detectores muito utilizados para se realizar o controle de qualidade de equipamentos que utilizam radiação, como os mamógrafos. No presente trabalho foram utilizadas quatro câmaras de ionização desenvolvidas no Laboratório de Calibração de Instrumentos do IPEN LCI/IPEN, que foram submetidas a testes de caracterização em feixes padrões de radiação X do LCI. Elas apresentaram resultados satisfatórios, dentro dos limites estabelecidos pelas normas nacionais e internacionais. Como aplicação, estas câmaras de ionização foram utilizadas para testes de controle de qualidade em quatro mamógrafos clínicos de diferentes instituições quanto à repetibilidade e linearidade da taxa de kerma no ar. Os resultados obtidos nestes testes encontram-se dentro dos limites recomendados pelas normas nacionais e internacionais. / Mammography is an examination in mammography, which uses X-rays to obtain images of the internal anatomy of the breast. To provide a correct diagnosis, it is necessary that the equipment constantly undergo quality control programs to ensure that patients submitted to this examination do not receive more than the necessary dose, thus avoiding unwanted possible biological effects. The ionization chambers are widely used detectors to perform the quality control program of equipment with radiation, as mammographers. In the present study, four different special ionization chambers, developed at the Calibration Laboratory of Instruments of IPEN - LCI / IPEN, were submitted to the characterization tests in standard X radiation beams at the LCI. The results were satisfactory, within the limits estabilished by national and international standards. As an application, the ionization chambers were used for quality control tests in four mammography clinics from different institutions, as the repeatability and linearity of the air kerma rate. The results obtained in these tests were within the limits recommended by national and international standards.
5

Estudo de indicadores de qualidade nas mulheres com câncer de mama  detectato pelo programa de rastreamento mamográfico do Hospital de Câncer de Barretos / Quality performance indicators in women with breast cancer detected by the mammographic screening program from Barretos Cancer Hospital

Tsunoda, Audrey Tieko 07 February 2012 (has links)
Os programas de rastreamento mamográfico (PRM) organizados atingem redução de mortalidade por câncer de mama em até 35%, principalmente quando submetidos a controle de qualidade efetivo. O PRM realizado pelo Hospital de Câncer de Barretos (HCB) é oferecido através de Unidades Móveis e Fixa desde 2003, para mulheres entre 40 e 69 anos, pertencentes à V Regional de Saúde do Estado de São Paulo Barretos (DRS). Trata-se de um projeto pioneiro no Brasil que necessita enquadrar-se em critérios de controle de qualidade para que atinja resultados comparáveis aos da literatura. Objetivo: Este estudo visa avaliar os indicadores de qualidade de detecção e tratamento das pacientes portadoras de câncer de mama diagnosticadas pelo PRM-HCB na DRS-V de São Paulo, entre 2003 e 2010. Métodos: Foram revisados os prontuários de todas as pacientes com câncer de mama, detectados pelo PRM-HCB no período. Os indicadores de controle de qualidade incluíram dados de: estadiamento, diagnóstico, tratamento, laudo patológico, intervalos de tempo, e dados descritivos. As pacientes sintomáticas tiveram os indicadores analisados em separado das assintomáticas. As variáveis contínuas e categóricas foram comparadas aos parâmetros estabelecidos pela European Breast Cancer Network (EBCN), utilizando-se o programa SPSS 15. Resultados: Foram incluídas 257 mulheres. Os estádios clínicos 0 e I compreenderam 68,3% (125/183) dentre as assintomáticas e 33,8% (24/71) das sintomáticas, com 3 casos sem informação (nível desejável >70%). O tamanho médio do tumor foi de 1,96cm entre as assintomáticas e de 3,2cm dentre as sintomáticas (p=0,000). A cirurgia foi conservadora em 85,2% das assintomáticas e em 62,5% das sintomáticas. Dentre os 25 indicadores adequadamente avaliados, 18 encontravam-se em níveis desejáveis, sendo 7 deles a respeito da adequação do tratamento cirúrgico. Um dos indicadores de tempo esteve em nível aceitável (tempo entre a indicação de cirurgia e o procedimento cirúrgico médio de 17,9 dias úteis, nível aceitável = 15du), enquanto outros 2 estiveram insuficientes. Os intervalos de tempo para o laudo anátomo-patológico (AP) estiveram em níveis satisfatórios (82,1% dos laudos AP de diagnóstico em 10du ou menos, nível desejável 80%). As principais deficiências relacionadas ao tempo foram da mamografia de rastreamento até a matrícula (média de 32du, nível aceitável = 5du) e da matrícula aos demais exames diagnósticos (média de 27du; nível aceitável = 5du). Conclusões: Os indicadores de estádio dentre as mulheres assintomáticas estiveram em níveis aceitáveis, entretanto, as mulheres sintomáticas apresentaram tumores maiores e em estádios mais avançados. A abordagem multidisciplinar como Unidade de Mama possibilitou atingir níveis adequados e comparáveis aos europeus quanto aos métodos diagnósticos e terapêuticos. Deficiências quanto aos intervalos de tempo e barreiras que dificultam a adesão da população demandam intervenções futuras. A análise de indicadores de qualidade foi factível e permitiu diagnosticar uma adequação parcial dos processos de diagnóstico e tratamento das pacientes com câncer de mama detectado pelo PRM-HCB, segundo os critérios estabelecidos pela EBCN / In order to achieve a reduction of 35% in breast cancer mortality, organized mammographic screening (MMGS) programs demand quality assurance. BCH has been offering MMGS for 40 to 69-year-old women, since 2003, by means of three mobile units and a standardized breast unit, through the public health system. It is a pioneer Brazilian project, in a São Paulo State nonmetropolitan setting, that has to attend quality assurance to achieve results comparable to those presented in the actual literature. Objective: This study aims to analyze the quality performance indicators regarding diagnosis methods and treatment offered to women whose breast cancer was detected by the BCH MMGS program, between 2003 and 2010. Methods: We reviewed the medical records of breast cancer patients whose disease was detected by the BCH MMGS program during the period. Quality indicators included data about: stage, diagnosis, treatment, pathology, time intervals, and descriptive information. Symptomatic women at the moment of the first evaluation had their data evaluated separately from the asymptomatic. The data gathered were analyzed using SPSS 15. The results were compared to the European Breast Cancer Network Guidelines for quality assurance. Results: 257 patients were included in this study. Stages 0 and I corresponded to 68.3% (125/183) of the asymptomatic cases, and 33.8% (24/71) of the symptomatic group (desirable level >70%), with 3 missing cases. The mean tumor size was 1.96cm for the asymptomatic patients, and 3.2cm for the symptomatic (p=0.000). Breast conserving surgery was possible in 85.2% of the asymptomatic patients, and in 62.5% of the symptomatic. Among the 25 quality indicators adequately evaluated, 18 were in desirable levels. Seven of them were related to the surgical approach. One of the time interval indicators was considered acceptable (mean time interval between decision to operate and date of surgery = 17.9 working days, acceptable level = 15wd), but 2 were in insufficient levels. Time intervals for pathology reports were sufficient (82.1% of the diagnostic pathology reports were performed in 10wd or less, desirable level80%). Main deficiencies were related to time interval between the mammogram and the first evaluation (mean=32wd, acceptable level=5wd) and the evaluation and the results of the additional exams (mean=27wd, acceptable level=5wd). Conclusions: Stage quality indicators were adequate for the asymptomatic group. Symptomatic women had larger tumors, with more advanced stages. The multidisciplinary approach was important to achieve acceptable and desirable levels regarding diagnostic methods and treatment. Deficiencies concerning time intervals and possible barriers that represent delays demand a future action plan. The analysis of quality indicators was feasible and allowed to diagnose a partial adjustment in the diagnostic and treatment process of the cancer patients detected by the BCH MMGS based on the EBCN Guidelines criteria
6

Estudo de indicadores de qualidade nas mulheres com câncer de mama  detectato pelo programa de rastreamento mamográfico do Hospital de Câncer de Barretos / Quality performance indicators in women with breast cancer detected by the mammographic screening program from Barretos Cancer Hospital

Audrey Tieko Tsunoda 07 February 2012 (has links)
Os programas de rastreamento mamográfico (PRM) organizados atingem redução de mortalidade por câncer de mama em até 35%, principalmente quando submetidos a controle de qualidade efetivo. O PRM realizado pelo Hospital de Câncer de Barretos (HCB) é oferecido através de Unidades Móveis e Fixa desde 2003, para mulheres entre 40 e 69 anos, pertencentes à V Regional de Saúde do Estado de São Paulo Barretos (DRS). Trata-se de um projeto pioneiro no Brasil que necessita enquadrar-se em critérios de controle de qualidade para que atinja resultados comparáveis aos da literatura. Objetivo: Este estudo visa avaliar os indicadores de qualidade de detecção e tratamento das pacientes portadoras de câncer de mama diagnosticadas pelo PRM-HCB na DRS-V de São Paulo, entre 2003 e 2010. Métodos: Foram revisados os prontuários de todas as pacientes com câncer de mama, detectados pelo PRM-HCB no período. Os indicadores de controle de qualidade incluíram dados de: estadiamento, diagnóstico, tratamento, laudo patológico, intervalos de tempo, e dados descritivos. As pacientes sintomáticas tiveram os indicadores analisados em separado das assintomáticas. As variáveis contínuas e categóricas foram comparadas aos parâmetros estabelecidos pela European Breast Cancer Network (EBCN), utilizando-se o programa SPSS 15. Resultados: Foram incluídas 257 mulheres. Os estádios clínicos 0 e I compreenderam 68,3% (125/183) dentre as assintomáticas e 33,8% (24/71) das sintomáticas, com 3 casos sem informação (nível desejável >70%). O tamanho médio do tumor foi de 1,96cm entre as assintomáticas e de 3,2cm dentre as sintomáticas (p=0,000). A cirurgia foi conservadora em 85,2% das assintomáticas e em 62,5% das sintomáticas. Dentre os 25 indicadores adequadamente avaliados, 18 encontravam-se em níveis desejáveis, sendo 7 deles a respeito da adequação do tratamento cirúrgico. Um dos indicadores de tempo esteve em nível aceitável (tempo entre a indicação de cirurgia e o procedimento cirúrgico médio de 17,9 dias úteis, nível aceitável = 15du), enquanto outros 2 estiveram insuficientes. Os intervalos de tempo para o laudo anátomo-patológico (AP) estiveram em níveis satisfatórios (82,1% dos laudos AP de diagnóstico em 10du ou menos, nível desejável 80%). As principais deficiências relacionadas ao tempo foram da mamografia de rastreamento até a matrícula (média de 32du, nível aceitável = 5du) e da matrícula aos demais exames diagnósticos (média de 27du; nível aceitável = 5du). Conclusões: Os indicadores de estádio dentre as mulheres assintomáticas estiveram em níveis aceitáveis, entretanto, as mulheres sintomáticas apresentaram tumores maiores e em estádios mais avançados. A abordagem multidisciplinar como Unidade de Mama possibilitou atingir níveis adequados e comparáveis aos europeus quanto aos métodos diagnósticos e terapêuticos. Deficiências quanto aos intervalos de tempo e barreiras que dificultam a adesão da população demandam intervenções futuras. A análise de indicadores de qualidade foi factível e permitiu diagnosticar uma adequação parcial dos processos de diagnóstico e tratamento das pacientes com câncer de mama detectado pelo PRM-HCB, segundo os critérios estabelecidos pela EBCN / In order to achieve a reduction of 35% in breast cancer mortality, organized mammographic screening (MMGS) programs demand quality assurance. BCH has been offering MMGS for 40 to 69-year-old women, since 2003, by means of three mobile units and a standardized breast unit, through the public health system. It is a pioneer Brazilian project, in a São Paulo State nonmetropolitan setting, that has to attend quality assurance to achieve results comparable to those presented in the actual literature. Objective: This study aims to analyze the quality performance indicators regarding diagnosis methods and treatment offered to women whose breast cancer was detected by the BCH MMGS program, between 2003 and 2010. Methods: We reviewed the medical records of breast cancer patients whose disease was detected by the BCH MMGS program during the period. Quality indicators included data about: stage, diagnosis, treatment, pathology, time intervals, and descriptive information. Symptomatic women at the moment of the first evaluation had their data evaluated separately from the asymptomatic. The data gathered were analyzed using SPSS 15. The results were compared to the European Breast Cancer Network Guidelines for quality assurance. Results: 257 patients were included in this study. Stages 0 and I corresponded to 68.3% (125/183) of the asymptomatic cases, and 33.8% (24/71) of the symptomatic group (desirable level >70%), with 3 missing cases. The mean tumor size was 1.96cm for the asymptomatic patients, and 3.2cm for the symptomatic (p=0.000). Breast conserving surgery was possible in 85.2% of the asymptomatic patients, and in 62.5% of the symptomatic. Among the 25 quality indicators adequately evaluated, 18 were in desirable levels. Seven of them were related to the surgical approach. One of the time interval indicators was considered acceptable (mean time interval between decision to operate and date of surgery = 17.9 working days, acceptable level = 15wd), but 2 were in insufficient levels. Time intervals for pathology reports were sufficient (82.1% of the diagnostic pathology reports were performed in 10wd or less, desirable level80%). Main deficiencies were related to time interval between the mammogram and the first evaluation (mean=32wd, acceptable level=5wd) and the evaluation and the results of the additional exams (mean=27wd, acceptable level=5wd). Conclusions: Stage quality indicators were adequate for the asymptomatic group. Symptomatic women had larger tumors, with more advanced stages. The multidisciplinary approach was important to achieve acceptable and desirable levels regarding diagnostic methods and treatment. Deficiencies concerning time intervals and possible barriers that represent delays demand a future action plan. The analysis of quality indicators was feasible and allowed to diagnose a partial adjustment in the diagnostic and treatment process of the cancer patients detected by the BCH MMGS based on the EBCN Guidelines criteria
7

Změna kvality života žen s diagnostikovaným karcinomem prsu / The change in quality of life with women diagnosed breast cancer

HOLANOVÁ, Gabriela January 2008 (has links)
Professional treatises and articles in commercial media having breast carcinoma in the heading characterize it mostly as an epidemiologically serious phenomenon. This fact cannot be doubted regarding to occurrence of this carcinoma disorder of women (in minimal cases of men). At present the patients become co-coordinators of the treatment in far bigger rate than they used to. Studies and practical experience in this context show that only quantitative aspects of life like the length are not the determined ones for the patient, but more and more patients prefer quality of the survival. Traditional medicine under the pressure of such findings tends to modify treatment procedures in relation with keeping certain quality of life of oncological patients. That is the reason why traditional medicine in the objectives of psychooncology specialization maps the rate of such level, searches preferences of the patients in context of type of the carcinoma, the stage of the disease, individual emotional attitudes etc. Psychooncology becomes an equal partner to radiology, surgery, pathology, oncology and psychology itself in terms of help patients. The possibility to provide psychooncological investigation in the centre of diagnosis and treatment of breast carcinoma of women Mamografie Nemocnice Písek a.s. and to process the data by the form of diploma work seemed purposeful in this case. In the theoretical part initial conditions of breast carcinoma by traditional medicine were defined {--} diagnosis, cure and consecutive treatment. Common emotional maps while facing cancer diagnosis were defined. Methods of determination quality of life of patients in historical and contemporary trends were mentioned. The selected methodology was described by the form of partially anonymous questionnaires and investigative file of 128 women was characterized. The aim of this work was to search the women with diagnosis of breast carcinoma and development of their partnerships, relationships in extended family, inter - personal relationships at work and to compare quantifiable parameters with the time before setting the diagnosis. Mapping somatic (tiredness, pain, insomnia, digestive problems) and psychosomatic factors determining quality of life of sick women was the major axis of searching and investigation. These aims were applied to defined hypotheses which dealt with goals mentioned in the context of contemporary state of comprehension to help people with oncological diagnosis: breast carcinoma is not only serious somatic problem but also psychosocial issue although psychooncology is not the specialization systematically incorporated into the complex oncological solution of patients at the moment. Dates result in the fact that the factors which contribute most to the quality of life concerning to somatic influences are negatively felt tiredness followed by pain afterwards. The dominant psychical influences include depression, anxiety and insomnia. In psychosocial sphere social support is unambiguously dominantly important for quality of life and according to the literature it can contribute even to the length of survival. Following the data, lucid absence of psychooncological help in early stages after detected disorder and during contingent recovery seemed insufficient. The diploma work was not purposeless. There was a deep interest and support of all medical staff of the mammography centre. If we succeed to include psychooncological intervention into a set of conditions asserted in the horizon of treatment of breast cancer, then the data will daily contribute to help of sick women. By generalization it is possible to outline the way in understanding the complex treatment and solving further oncological diagnoses and procedures.
8

DETECÇÃO DE MASSAS EM IMAGENS MAMOGRÁFICAS ATRAVÉS DO ALGORITMO GROWING NEURAL GAS E DA FUNÇÃO K DE RIPLEY / DETECTION OF MASSES IN MAMOGRAPHY THROUGH ALGORITMA NEURAL GAS AND GROWING ROLE OF K RIPLEY

Martins, Leonardo de Oliveira 07 December 2007 (has links)
Made available in DSpace on 2016-08-17T14:53:26Z (GMT). No. of bitstreams: 1 Leonardo Martins.pdf: 1400853 bytes, checksum: 3b6aa06e1c4b580a53150460124fdeaa (MD5) Previous issue date: 2007-12-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Breast cancer is a serious public health problem in several countries of the world. Computer-Aided Detection/Diagnosis systems (CAD/CADx) have been used with relative success in aid to health care professionals. The goal of such systems is not to replace the professional, but join forces in order to early detect the different types of cancer. The main contribution of this work is to present a methodology for detecting masses in digitized mammograms using the algorithm Growing Neural Gas for the segmentation of the image and Ripley’s K function to describe the texture of segmented objects. The classification of these objects is accomplished through a Support Vector Machine (SVM), which separates them into two groups: masses and non-masses. The methodology obtained 89,30% of accuracy and a rate of 0,93 false-positive per image. / O câncer de mama apresenta-se como um grave problema de saúde pública em vários países do mundo. Sistemas de Detecção e Diagnóstico baseados em computador (CAD/CADx) vêm sendo usados com relativo sucesso no auxílio aos profissionais de saúde. O objetivo de tais sistemas não é substituir o profissional, mas unir forças com o objetivo de detectar precocemente os diferentes tipos de câncer. A principal contribuição deste trabalho é apresentar uma metodologia para detecção de massas em imagens mamográficas digitais, utilizando para tanto o algoritmo Growing Neural Gas para a segmentação da imagem e a função K de Ripley para descrever a textura dos objetos segmentados. A classificação desses objetos é feita através de uma Máquina de Vetor de Suporte (Support Vector Machine - SVM), a qual separa os mesmos em dois grupos: massa e não-massa. A metodologia obteve 89,30% de acerto e uma taxa de 0,93 falso-positivos por imagem.

Page generated in 0.054 seconds