• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 283
  • 149
  • 17
  • 13
  • 8
  • 6
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 517
  • 139
  • 60
  • 58
  • 54
  • 54
  • 52
  • 52
  • 51
  • 51
  • 50
  • 47
  • 46
  • 45
  • 44
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Distraction osteogenesis of irradiated rabbit mandible with and without hyperbaric oxygen therapy

Muhonen, Arja. January 2002 (has links)
Thesis--University of Turku, Finland, 2002. / Includes bibliographical references.
202

A comparison of static and graphic means of recording sagittal condylar guidance

Berg, James E. January 1983 (has links)
Thesis (M.S.)--University of Michigan, Ann Arbor, 1983. / Typescript (photocopy). eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 45-48).
203

Vastatin, a novel angiogenesis inhibitor, retards condylar bone growth in vivo /

Li, Qianfeng. January 2009 (has links)
Thesis (Ph. D.)--University of Hong Kong, 2009. / Includes bibliographical references (leaves 116-130). Also available online.
204

Replicating mesenchymal cells in the condyle in response to normal growth and mandibular protrusion

Tsai, Ming-ju, Marjorie. January 2002 (has links)
Thesis (M. Orth.)--University of Hong Kong, 2002. / Includes bibliographical references (leaves 114-140). Also available in print.
205

Replicating mesenchymal cells in the glenoid fossa in response to mandibular advancement

Wong, Shu-hing, Louise. January 2002 (has links)
Thesis (M. Orth.)--University of Hong Kong, 2002. / Includes bibliographical references (leaves 109-135). Also available in print.
206

Desenvolvimento, comportamento mecânico e microestrutural de uma prótese mandibular em liga de titânio produzida por sinterização direta a laser de metal (DMLS)

Gregolin, Rafael Ferreira [UNESP] 20 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-20Bitstream added on 2014-06-13T20:35:19Z : No. of bitstreams: 1 gregolin_rf_me_ilha.pdf: 3746269 bytes, checksum: b2a1686375b3a28a8709c13b5b75a4bd (MD5) / A prototipagem rápida está sendo utilizada em diversas áreas do conhecimento humano para auxiliar no estudo e muitas vezes na própria fabricação do componente usual. Atualmente, com o avanço de softwares, pode-se criar com facilidade imagens tridimensionais, ou mesmo, capturar essas imagens de equipamentos como a tomografia computadorizada e a ressonância magnética. Consegue-se reproduzir qualquer parte do corpo humano com grande perfeição e isso é utilizado na fabricação de implantes, scaffolds (arcabouços – engenharia de tecidos), materiais de auxílio e preparação em cirurgias (biomodelos). Os principais materiais utilizados na fabricação de implantes hoje são: o titânio puro, as ligas de titânio, o aço inoxidável, o polietileno, o PMMA, as ligas de cobalto-cromo e as cerâmicas. Este trabalho se propõe a fazer: um estudo mecânico e microestrutural da liga Ti-6Al-4V obtida por prototipagem rápida no processo de sinterização direta a laser de metais (DMLS) e compará-la com a liga Ti-6Al-4V produzida por processos convencionais de conformação (trefilação). Além disso, pretende realizar o desenvolvimento de uma placa condilar personalizada utilizada para patologias de distúrbios de ATM (articulação têmporo-mandibular), avaliando sua geometria pelo software ANSYS®, com o apoio da tomografia computadoriza e do software de construção de imagens tridimensionais INVESALIUS® / Rapid prototyping is being used in various areas of human knowledge to assist in the study and often in the usual component manufacturing. Today, with the advancement of software, you can easily create three-dimensional images, or even, capture these images of equipment such as computed tomography and magnetic resonance imaging. You able to reproduce any part of the human body with great perfection and it’s used in the manufacture of implants, scaffolds (tissue engineering), material aid and preparation for surgery (biomodels). The main materials used in the manufacture of implants today are: pure titanium, titanium alloys, stainless steel, polyethylene, PMMA, the cobalt-chromium alloys and ceramics. This paper proposes to do: mechanical and microstructural studies of alloy Ti-6Al-4V obtained by rapid prototyping process in direct metal laser sintering (DMLS) and compare it with the Ti-6Al-4V alloy produced by conventional forming process (wiredrawing). Also, make the development of a custom condylar plate used for diseases of TMJ (temporomandibular joint) disorders, assessing its geometry by ANSYS® software with the help of computerized tomography and the software to build three-dimensional images INVESALIUS®
207

Comparação de dois sistemas de imagem para avaliação do perfil de tecido mole em cirurgia ortognática /

Érnica, Natasha Magro. January 2006 (has links)
Resumo: O objetivo deste estudo foi avaliar subjetivamente a imagem de perfil de tecido mole predictiva gerada por computador, em pacientes submetidos à cirurgia ortognática de avanço mandibular isolado, e, conseqüentemente, se o uso dela é aceitável para comunicação e elucidação do paciente durante o plano de tratamento, comparando os programas Dolphin Imaging e Dentofacial Planner Plus. Doze pacientes portadores de deficiência mandibular horizontal foram fotografados de perfil no préoperatório e 5 meses depois da cirurgia, no mínimo, sendo as imagens pós-operatórias confrontadas com as imagens predictivas produzidas pelos programas de imagem. Essas imagens foram analisadas por 100 cirurgiões-dentistas (50 cirurgiões buco-maxilo-faciais e 50 ortodontistas) que preencheram uma tabela de análise para cada imagem avaliada. Os resultados mostraram que: 1) O programa Dolphin Imaging foi o mais citado nos escores "excelente" e "muito bom" em todos os pontos de análise (ponta nasal, ângulo nasolabial, lábio superior, lábio inferior, região mentoniana, base mandibular, sulco lábio-mentoniano e geral), enquanto o programa Dentofacial Planner Plus foi o mais citado nos escores "regular" e "ruim"; 2) No escore "bom" houve um empate entre os dois programas nos pontos ‘lábio superior’ e ‘lábio inferior’, sendo o programa Dentofacial Planner Plus preferido para o ponto ‘base mandibular’ e o programa Dolphin Imaging para os demais pontos de análise (ponta nasal, ângulo nasolabial, região mentoniana, sulco lábio-mentoniano e geral); e 3) Existe uma predominância média de escores "muito bom e "bom" para o programa Dolphin Imaging e de escores "bom" e "regular" para o programa Dentofacial Planner Plus. Deste modo, nas imagens de avanço mandibular, diante da metodologia empregada e dos dados obtidos no presente estudo,...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate subjectively computer-generated soft tissue profile prediction in patients who underwent orthognathic surgery for mandibular advancement only and, consequently, if its usage is acceptable as a patient communication and education tool during the treatment plan. Two softwares were compared: Dolphin Imaging and Dentofacial Planner Plus. Pictures were taken from twelve patients with mandibular hypoplasia in the preoperative and at least 5 months postoperative period. The postoperative images were compared with the prediction generated by the two softwares. These images were evaluated by 100 dentists (50 oralmaxillofacial surgeons and 50 orthodontists) who filled in one correspondent table to each analyzed image. The results showed that: 1) Dolphin Imaging software was mentioned more times as excellent and very good in every analysis point (tip of the nose, nasolabial angle, upper lip, lower lip, chin, mandibular base, labiomental fold, and general), while Dentofacial Planner Plus software was scored fair and poor more frequently. 2) For the score "good", there was a tie between the two softwares at the points upper lip and lower lip, and the software Dentofacial Planner Plus was preferred to the mandibular base point, while Dolphin Imaging was to all the other points left (tip of the nose, nasolabial angle, chin, labiomental fold, and general); and, 3) The majority of the mean scores were very good and good to Dolphin Imaging and good and fair to Dentofacial Planner Plus. Thus, according to the methodology and data obtained it is possible to conclude that to mandibular advancement images: the data show that both softwares are well accepted to soft tissue profile prediction, which suggests that both of them can be used as a communication tool with the patient during the treatment plan. However, Dolphin Imaging showed better results in this present study. / Orientador: Idelmo Rangel Garcia Júnior / Coorientador: Pedro Felipe Franco / Banca: Fábio Yoshio Tanaka / Banca: Laura Guimarães Pagliuso Paleckis / Banca: Osmar Aparecido Cuoghi / Banca: Eduardo Hochuli Vieira / Doutor
208

Desenvolvimento, comportamento mecânico e microestrutural de uma prótese mandibular em liga de titânio produzida por sinterização direta a laser de metal (DMLS) /

Gregolin, Rafael Ferreira. January 2013 (has links)
Orientador: Ruis Camargo Tokimatsu / Banca: João Antonio Pereira / Banca: Cecilia Amelia de Carvalho Zavaglia / Resumo: A prototipagem rápida está sendo utilizada em diversas áreas do conhecimento humano para auxiliar no estudo e muitas vezes na própria fabricação do componente usual. Atualmente, com o avanço de softwares, pode-se criar com facilidade imagens tridimensionais, ou mesmo, capturar essas imagens de equipamentos como a tomografia computadorizada e a ressonância magnética. Consegue-se reproduzir qualquer parte do corpo humano com grande perfeição e isso é utilizado na fabricação de implantes, scaffolds (arcabouços - engenharia de tecidos), materiais de auxílio e preparação em cirurgias (biomodelos). Os principais materiais utilizados na fabricação de implantes hoje são: o titânio puro, as ligas de titânio, o aço inoxidável, o polietileno, o PMMA, as ligas de cobalto-cromo e as cerâmicas. Este trabalho se propõe a fazer: um estudo mecânico e microestrutural da liga Ti-6Al-4V obtida por prototipagem rápida no processo de sinterização direta a laser de metais (DMLS) e compará-la com a liga Ti-6Al-4V produzida por processos convencionais de conformação (trefilação). Além disso, pretende realizar o desenvolvimento de uma placa condilar personalizada utilizada para patologias de distúrbios de ATM (articulação têmporo-mandibular), avaliando sua geometria pelo software ANSYS®, com o apoio da tomografia computadoriza e do software de construção de imagens tridimensionais INVESALIUS® / Abstract: Rapid prototyping is being used in various areas of human knowledge to assist in the study and often in the usual component manufacturing. Today, with the advancement of software, you can easily create three-dimensional images, or even, capture these images of equipment such as computed tomography and magnetic resonance imaging. You able to reproduce any part of the human body with great perfection and it's used in the manufacture of implants, scaffolds (tissue engineering), material aid and preparation for surgery (biomodels). The main materials used in the manufacture of implants today are: pure titanium, titanium alloys, stainless steel, polyethylene, PMMA, the cobalt-chromium alloys and ceramics. This paper proposes to do: mechanical and microstructural studies of alloy Ti-6Al-4V obtained by rapid prototyping process in direct metal laser sintering (DMLS) and compare it with the Ti-6Al-4V alloy produced by conventional forming process (wiredrawing). Also, make the development of a custom condylar plate used for diseases of TMJ (temporomandibular joint) disorders, assessing its geometry by ANSYS® software with the help of computerized tomography and the software to build three-dimensional images INVESALIUS® / Mestre
209

Efeitos da expansão rápida da maxila na posição do côndilo em tomografias computadorizadas - Cone Beam

Squeff, Karine January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:18Z (GMT). No. of bitstreams: 2 000433584-0.pdf: 1265477 bytes, checksum: 96aee194604ab9b5877f91c360a53158 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Introduction: The condyle position in relation to the joint cavity may serve as a basis for studies related to temporo maxillo mandibular disorders (TMD). During the rapid maxillary expansion (RME), an intense activity occurs between sutural bones in which the jaw is articulated, including the temporomandibular joint (TMJ). Cone beam computed tomography (CBCT) now allow the possibility to visualize the position of the condyle in coronal, sagittal and axial views, which before, due to anatomical reasons, was always difficult to interpret.Objectives: Propose a method to standardize the assessment of the cranium to assess the condyle using CBCT and to evaluate the condyle position in relation to the joint cavity before, immediately after and six months after the ERM, in the axial and sagittal ways in CBCT.This was a retrospective study with patients aged 7 to 14 years. Inter and intra-examiner measurements of 10 CBCT were made of the condylar position in relation to the joint cavity. To standard the position of the head, anatomical stable structures and easily identified were used. Data was analyzed using descriptive measures (mean and standard deviation). After that, 34 patients were evaluated, 11 males and 23 females, with constricted maxilla without crossbite (group 1), and unilateral crossbite (group 2). The size of the condyle (TCO), the superior space (ES), posterior space (EP), anterior space (EA) and the angulation of the condyle (AC) was measured. It was evaluated the position of the condyle in relation to the joint cavity - anterior, centered or posterior.Results: The statistical results indicated intra and inter-examiner reliability. In groups 1 and 2, it was not observed a pattern changes in relation to initial condyle position (anterior, central or posterior). There was a transient change immediately after the ERM, with increased the ES and EA of the condyle in relation to the joint cavity, but in six months after the ERM it was back to the initial position. In group 2, in the crossbite side, six months after the ERM there was a return of the condyle to its original position. In group 2, not cross-side, there was an increase in the EA that occurred immediately after the ERM, with a slight reduction in six months, but still increased compared to the initial position. TCO and AC showed no significant differences in the groups and times evaluated. There was no statistical difference between genders also.It was found high reliability and methodology in the study demonstrated stable assessments of condylar position in relation to the glenoid fossa in CBCT. There was not a definite pattern in the changing of the condyle position before, immediately and six months after the ERM. There was a transient change immediately after the ERM, with increased space superior and anterior condyle in relation to the joint cavity and in six months after the ERM back to initial position. / Introdução: O conhecimento da posição do côndilo em relação à cavidade articular pode servir como base para estudos relacionados às desordens têmporo maxilo-mandibulares (DTMs). Durante a expansão rápida da maxila (ERM), uma intensa atividade sutural ocorre entre os ossos com os quais a maxila se articula, incluindo a articulação temporomandibular (ATM). Com a Tomografia computadorizada Cone Beam (TCCB) é possível visualizar a posição do côndilo na cavidade articular no sentido coronal, sagital e axial, o que antes, devido a questões anatômicas, sempre foi de difícil interpretação.Objetivos: Propor uma metodologia de posicionamento do crânio para avaliação do côndilo e realizar a avaliação da posição condilar em relação à cavidade articular em TCCB, antes, imediatamente após e seis meses depois da ERM, no sentido axial e sagital.Metodologia: Neste estudo retrospectivo, com pacientes entre 7 e 14 anos, foram realizadas medidas inter e intraexaminadores em 10 TCCB da posição condilar em relação à cavidade articular, padronizando a posição da cabeça e côndilo através de estruturas anatômicas estáveis e de fácil identificação. Os dados foram analisados através de medidas descritivas (média e desvio-padrão). Após, foram avaliados 34 pacientes, 11 do sexo masculino e 23 do sexo feminino, com deficiência transversa da maxila. Mediu-se o tamanho do côndilo (TCo), espaço superior (ES), espaço posterior (EP), espaço anterior (EA) entre a cavidade articular e o côndilo e a angulação do côndilo (AC). A partir desses dados avaliou-se a posição do côndilo em relação à cavidade articular – anterior, centralizado ou posterior. Essas variantes foram medidas nos grupos com e sem mordida cruzada.Resultados: Os resultados estatísticos indicaram confiabilidade intraexaminador e interexaminadores para a metodologia proposta. Nos pacientes sem mordida cruzada, não foi observado um padrão em relação à posição condilar inicial (anterior, centralizada ou posterior). Houve uma modificação transitória, imediatamente após a ERM, com aumento do ES e EA em relação à cavidade articular que, em seis meses após a ERM, voltaram à posição inicial. No grupo com mordida cruzada, também não houve um padrão em relação à posição condilar inicial e houve mudanças transitórias imediatamente após a ERM. Nos pacientes com mordida cruzada no lado da mordida cruzada, seis meses após a ERM houve um retorno do côndilo à sua posição inicial. No lado oposto, houve um aumento do EA que ocorreu imediatamente após a ERM, com leve redução em seis mas ainda aumentado em relação à posição inicial. O TCo e a AC não apresentaram diferenças significativas nos grupos e tempos avaliados. Não houve diferença estatística entre os gêneros para a posição condilar antes, imediatamente e seis meses após a ERM.Conclusões: Foi encontrada alta confiabilidade das medidas avaliadas, sendo a metodologia demonstrada no estudo precisa para realização de avaliações da posição do côndilo em relação à cavidade articular. Não houve um padrão definido na mudança da posição do côndilo. Houve uma modificação transitória, imediatamente após a ERM, com aumento do ES e EA em relação à cavidade articular que, em seis meses após a ERM, voltaram à posição inicial.
210

Estudo morfológico e análise da microdureza da dentina na área de furca de dentes molares inferiores / Morphological study and analysis of the dentin microhardness in furcation areas of mandibular molars

Luís Eduardo Souza Flamini 16 October 2012 (has links)
O presente trabalho teve como objetivo avaliar a microdureza dentinária da região da furca de molares inferiores, assim como estudar, por meio da MEV, a morfologia da dentina nessa região. Utilizaram-se 10 espécimes, os quais tiveram a coroa seccionada transversalmente ao meio, sendo descartada a porção oclusal. As raízes mesial e distal foram cortadas próximas ao terço cervical, desprezando-se os terços médio e apical. O remanescente dental foi incluído em acrílico de rápida polimerização e cortado longitudinalmente ao meio, obtendo-se duas hemi-secções. Uma foi destinada ao estudo da morfologia, na qual observaram-se as características da dentina e o sentido dos canalículos dentinários. Na outra, realizou-se a análise da microdureza, por meio de aparelho de dureza Knoop, com carga de 10g por 15s. A área de furca foi estabelecida como sendo a região compreendida entre duas retas ortogonais traçadas a partir do ponto de máxima concavidade da superfície externa da bifurcação. A microdureza foi avaliada nas camadas de dentina superficial (próxima ao assoalho), média e interna (mais próxima à concavidade externa da furca), assim como nos três eixos, mesial (paralelo à reta traçada junto à mesial da furca), central (paralela à bissetriz entre as retas) e distal (paralela à reta traçada junto à distal). Realizaram-se cinco medidas para cada eixo, obtendo-se uma média por eixo. As mensurações foram submetidas à análise estatística (oneway ANOVA) ( &alpha;= 0,05). Os resultados mostraram não haver diferença significante (p>0,05) entre a dureza das porções mesial (46,5±6,4), central (47,3±8,1) e distal (49,7±6,5). Em relação às camadas, o teste de Tukey evidenciou diferença significante apenas entre as camadas interna (51,7±2,5) e externa (41,4±2,4) (p<0,05). As imagens da MEV mostraram que os canalículos dentinários assumem trajetória centrípeta em direção à porção interna. Os canalículos dentinários na camada externa apresentam-se amplos e com a luz bastante evidente. Na camada média os canalículos são mais atresiados, ao passo que na interna, a dentina assemelha-se à dentina esclerótica. Conclui-se que a microdureza dentinária na área de furca é uniforme nos 3 eixos. A camada interna é mais dura que a externa. A dentina da região de furca parece ser um tecido bastante mineralizado, tendendo a uma maior calcificação dos canalículos à medida que se aproxima da camada interna. / The aim of this study was to evaluate the dentin microhardness in furcation areas of mandibular molars and to study the dentin morphology in these regions by scanning electron microscopy (SEM). The crows of ten specimens were transversely sectioned and the occlusal portions were discarded. The mesial and distal roots were cut near to the cervical third ignoring the middle and apical thirds. The remaining teeth were included in rapid polymerization acrylic stubs and cut longitudinally resulting in two hemi-sections. One was designed to study the morphology in which was possible to observe characteristics of the dentin and dentinal tubules direction. The other one was used to perform analysis of the microhardness using a Knopp device with load of 10g/15s. The furcation areas were established as the regions between two orthogonal lines drawn from the point of maximum concavity of the outer surface of the bifurcation. Microhardness was measured in the superficial layers of dentin (next to the floor), middle and inner (closest to the concavity of the external furcation), as well as in the three axes: mesial (parallel to the straight line along the mesial furcation), central (parallel to the bisectrix between the lines) and distal (parallel to the line drawn along the distal). Five measurements were performed for each axis yielding an average in each one. The measurements were subjected to statistical analysis (one way - ANOVA) (&alpha; = 0.05). The results showed no significant difference (p> 0,05) between the microhardness of the mesial (46.5±6.4), central (47.3±8.1) and distal portions (49.7±6.5). In relation to the layers, the Tukey test showed significant differences only between the inner (51.7±2.5) and outer (41.4±2.4) layers (p <0.05). The SEM images showed that the dentinal tubules assumes centripetal trajectory toward the inner portion. These ones, in the outer layer, presents larger and more evident. In the middle layer are thinner and in the inner layer the dentin is similar to sclerotic dentin. In this study was possible to observe that the microhardness of dentin in the furcation areas is uniform across to the three axes. The inner layer is harder than the outer. The dentin of the furcation areas appears to be a very mineralized tissue having a bigger calcification as it approaches to the inner layer.

Page generated in 0.0499 seconds