• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 203
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 208
  • 208
  • 82
  • 79
  • 50
  • 38
  • 33
  • 29
  • 28
  • 28
  • 24
  • 21
  • 21
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Caracterização mecânica e eletroquímica in vitro e in vivo da liga NiTi

Pértile, Luana Beatriz January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Ciência e Engenharia dos Materiais. / Made available in DSpace on 2013-07-16T00:34:30Z (GMT). No. of bitstreams: 1 229501.pdf: 3015107 bytes, checksum: 0b2e306ad09f5a52efabec0f7d645256 (MD5) / A utilizacao de metais ou ligas metalicas para o tratamento endovascular de arteriopatias requer condicoes estruturais e superficiais que propiciem funcionalidade e biocompatibilidade. A liga de NiTi pode atender a estes requisitos atraves de tratamentos termicos adequados e que resultem em propriedades mecanicas favoraveis a aplicacao e, resistencia a corrosao elevada. Atraves deste trabalho, procurou-se definir a condicao de tratamento termico ideal para se obter fios de NiTi superelasticos e com boas condicoes superficiais. Essas propriedades foram avaliadas atraves de ensaios mecanicos e eletroquimicos in vitro por meio de analise de variancia e teste t de Student. Para os ensaios in vivo foi validado um metodo de aquisicao de dados utilisando um eletrodo de pseudo-referencia de platina e um eletrodo de trabalhdo de NiTi. Elevadas temperaturas de tratamento termico dao origem a uma estrutura martensitica que favorece a propriedade de memoria de forma da liga NiTi, mas gera condicoes superficiais desfavoraveis para solicitacoes mecanicas e quimicas, reduzindo o tempo de vida sob fadiga e corrosao. Temperaturas de tratamento termico baixas favorecem a formacao de NiTi superelastico em funcao do tempo de processamento, mas geram superficies com menor incidencia de defeitos, propiciando um tempo de vida maior para o material. A condicao padrao de tratamento termico (CP) apresenta propriedades intermediarias de vida sob fadiga e, potenciais de corrosao e transpassivacao, quando comparada com as condicoes encruada (CP0), CP-T-t, CP+T+t, CP+T-t e CP-T+t, onde T representa variacao na teperatura e t variacao no tempo de tratamento termico. As reacoes eletroquimicas in vivo, para a condicao CP, podem ser bem simuladas atraves de ensaios eletroquimicos in vitro com solucao AFNOR S90-
122

Avaliação comparativa do potencial osteocondutor de quatro diferentes substitutos ósseos em defeitos críticos em calvárias de coelhos / Comparative evaluation of bone repairment with four different bone substitutes in critical size defects in rabbit's calvaria

Grossi-Oliveira, Gustavo Augusto [UNESP] 07 March 2016 (has links)
Submitted by GUSTAVO AUGUSTO GROSSI DE OLIVEIRA null (gustavo.grossi@yahoo.com.br) on 2016-05-01T17:18:32Z No. of bitstreams: 1 Tese Doutorado Gustavo Final.pdf: 9404416 bytes, checksum: 32752a911161af165740910dd9c737cd (MD5) / Rejected by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: O arquivo está corrompido. Por favor, verifique o formato do arquivo e realize uma nova submissão. Agradecemos a compreensão. on 2016-05-04T13:42:30Z (GMT) / Submitted by GUSTAVO AUGUSTO GROSSI DE OLIVEIRA null (gustavo.grossi@yahoo.com.br) on 2016-05-04T14:25:18Z No. of bitstreams: 1 Tese Doutorado Gustavo Grossi.pdf: 2626371 bytes, checksum: 9f1280249f56a937fc71c579f1201e3e (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-06T12:45:07Z (GMT) No. of bitstreams: 1 oliveira_gsg_dr_araca.pdf: 2626371 bytes, checksum: 9f1280249f56a937fc71c579f1201e3e (MD5) / Made available in DSpace on 2016-05-06T12:45:07Z (GMT). No. of bitstreams: 1 oliveira_gsg_dr_araca.pdf: 2626371 bytes, checksum: 9f1280249f56a937fc71c579f1201e3e (MD5) Previous issue date: 2016-03-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivos: Avaliar o potencial osteocondutor de quatro biomateriais utilizados no preenchimento de defeitos ósseos críticos em calvárias de coelhos. Material e métodos: 24 coelhos machos albinus foram submetidos à confecção de defeito ósseo de 8 mm de diâmetro na calvária bilateralmente. Os grupos foram divididos aleatoriamente pelos materiais utilizados: hidroxiapatita bovina - Bio-oss®(BIO), Lumina Bone Porus®(LBP) e Bonefill®(BFL) e, um material aloplástico - Clonos® (CLN), submetidos à eutanásia aos 14 e 40 dias após a cirurgia. A descalcificação das peças foi realizada e assim, as lâminas obtidas foram submetidas às análises histológica; análise histométrica, por meio da mensuração da área de osso neoformado (AON) no centro dos defeitos; análise imunoistoquímica, por meio da marcação do fator 2 de transcrição relacionado a Runt (Runx2), fator de crescimento do endotélio vascular (VEGF) e osteocalcina (OC). Os dados quantitativos foram submetidos à análise estatística (=0,05). Resultados: O grupo CLN mostrou maior AON nos dois períodos analisados em relação aos demais grupos (p<0,001, Teste Tukey). Aos 14 dias, o BIO foi superior quanto a AON aos grupos LBP e BFL, entretanto aos 40 dias, o grupo LBP superou os resultados do BIO (p<0,001, Teste Tukey). A imunomarcação para Runx2 mostrou diminuição na intensidade para BIO aos 40 dias, enquanto que aumentou para LBP (p<0,05, Teste Tukey). O CLN mostrou aumento para OC em comparação aos demais grupos em ambos os períodos analisados (p<0,05, Teste Tukey). Conclusões: O CLN apresentou o melhor comportamento osteocondutor em defeitos críticos na calvária de coelhos. / Objectives: To evaluate the osteoconductive potential of four biomaterials used in bone defects filling in rabbit’s calvaria. Methods: 24 male Albinus rabbits underwent to bone defect creation of 8 mm in diameter bilaterally in calvaria region. The groups were divided acordind to the bone substitute used to fill the calvaria defect: bovine hydroxyapatite - Bio-Oss ® (BIO), Lumina Bone Porus® (LBP) and Bonefill® (BFL), and an alloplastic material - Clonos® (CLN), and were submitted to euthanasia at 14 and 40 days after the surgery. The removed pieces were processed, histological slides were obtained and subjected to histological analysis; histometric analysis, through the measurement of newly formed bone area (NB) in the center of the defects; immunohistochemical analysis, by labelling the Runt-related transcription factor 2 (Runx2), vascular endothelial growth factor (VEGF) and osteocalcin (OC). Quantitative data were statistically analyzed (α = 0.05). Results: The CLN group showed greater AON in both periods analyzed in relation to the other groups (p <0.001, Tukey test). At 14 days, the AON showed greater values in BIO in relation with LBP and BFL groups, however , after 40 days, the LBP group surpassed the results of BIO (p <0.001, Tukey test). The immunostaining showed a decrease in Runx2 intensity in BIO after 40 days, while it increased for LBP (p <0.05, Tukey test). The CLN showed increased OC compared to the other groups in both periods analyzed (p <0.05, Tukey test). Conclusions: The CLN showed the best osteoconductive behavior in critical defects in rabbit’s calvaria.
123

Avaliação do reparo ósseo de cavidades preenchidas por vidro bioativo ou osso liofilizado desmineralizado: análises biomecânica, microscópica e histométrica em cães

Mendes, Vanessa Cristina [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:41:42Z : No. of bitstreams: 1 mendes_vc_dr_araca.pdf: 2490243 bytes, checksum: 6ce7b53f4434b723ec9c25c37375666f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos do presente estudo foram analisar e comparar, em cães, a reparação óssea em defeitos preenchidos com vidro bioativo e osso desmineralizado liofilizado e comparar com áreas que não receberam biomateriais, antes e após a inserção de implantes dentários de titânio. Cavidades com 6mm de diâmetro foram realizadas em ambos os úmeros de 6 cães machos saudáveis e preenchidas com vidro bioativo, osso liofilizado desmineralizado e coágulo. Após 5 meses de reparação, foi removido tecido ósseo do centro das cavidades para análise de microscopia óptica. A seguir, implantes dentários de titânio foram colocados no centro dessas cavidades e em áreas de osso pré-existente. Três meses depois, realizou-se o teste biomecânico de contra-torque dos implantes. Os cães foram sacrificados e o tecido ósseo encaminhado para processamento e análise de microscopia eletrônica por retroespalhamento de elétrons. No teste biomecânico não foram observadas diferenças estatisticamente significantes entre os 4 grupos. A análise de microscopia óptica demonstrou a presença de ambos os biomateriais e tecido ósseo neoformado na maioria das amostras do grupo experimental. Na microscopia eletrônica por retro-espalhamento de elétrons observou-se neoformação óssea em todos os grupos. Pela análise histométrica, a quantidade de neoformação óssea no grupo do vidro bioativo foi estatisticamente maior em relação aos outros grupos. Concluiu-se que o vidro bioativo apresentou os melhores resultados em porcentagem de neoformação óssea. No entanto, uma reparação satisfatória foi demonstrada em todos os grupos, com adequada qualidade óssea ao redor dos implantes dentários. / The objectives of the present study were to analyze and compare, in dogs, the bone healing in large areas grafted with bioactive glass and DFDBA to areas without any grafting, before and after the insertion of titanium dental implants. Cavities (6mm diameter) were drilled in both humeri of 6 healthy male dogs. The cavities were filled in with bioactive glass, DFDBA and clot. After 5 months, bone was removed from the centre of the cavities and processed for light microscopy analysis. Titanium dental implants were placed in these sites and in areas not previously drilled. Three months later, a biomechanical test was performed and the force necessary to unscrew the titanium implants was measured. Dogs were sacrificed and the bone removed. After embedding in PMMA, calcified samples were cut in half and polished for back-scattering SEM analysis. No statistically significant differences were observed among the 4 groups concerning the biomechanical test, according to the test U of Mann- Whitney. Light microscopy analysis showed the presence of both biomaterials among the regenerated bone. In the back-scattering analysis, regenerated bone was seen in all groups, and DFDBA presented the least volume. Remnants of granules of bioactive glass were still present, but in a smaller size. Because granules of DFDBA have the same image density of bone, if present, they couldn’t be identified. According to the test U of Mann-Whitney, the amount of bone formation in the bioactive glass group was statistically higher compared to the other groups. Based on the findings of this study, it was concluded that the bioactive glass showed best results in terms of bone volume. However, a satisfactory regeneration of bone in large defects with adequate bone quality was observed around dental implants in all groups.
124

Resposta tecidual ao enxerto xenógeno inorgânico de osso bovino: avaliação histomorfológica e histomorfométrica

Rodrigues, Thaís da Silveira [UNESP] 21 August 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-08-21Bitstream added on 2014-06-13T19:20:06Z : No. of bitstreams: 1 rodrigues_ts_dr_araca.pdf: 439179 bytes, checksum: 176184a10c13e6ef36390b6f5b61b9de (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição: Avaliar a resposta tecidual ao enxerto xenógeno inorgânico de osso bovino, por meio de análise histomorfológica e histomorfométrica. Material e método: O enxerto foi obtido da costela de boi resfriada após 8 horas de sacrifício do animal e processado da seguinte maneira: imersão por 60 minutos em água oxigenada a temperatura ambiente, com trocas a cada 15 minutos; imersão em água oxigenada aquecida, a uma temperatura de 100ºC, por 30 segundos e resfriamento imediato com água destilada a uma temperatura variando de 6º a 8ºC; enxague em água destilada corrente por 6 horas; imersão em álcool 70º, 90º e 100º, respectivamente, sendo 15 minutos em cada álcool; esterilização em autoclave. Em seguida, 10 coelhos brancos (Nova Zelândia) foram utilizados, originando dois grupos: Grupo I – enxerto inserido no pavilhão auricular e Grupo II – enxerto inserido e fixado em tíbia. Decorridos 180 dias, foi realizado sacrifício dos animais por injeção excessiva de anestésico. Resultados: No Grupo I, o enxerto apresentou-se em íntimo contato com tecido subcutâneo. No Grupo II, o enxerto apresentou-se em justaposição com o leito ósseo receptor. E nos dois grupos havia espaços medulares preenchidos por medula óssea ativa e osso neoformado, além da ausência de osteócitos no osso bovino e presença destas células no osso neoformado, próximo aos espaços medulares. Conclusão: Em razão dos resultados obtidos o enxerto xenógeno inorgânico de osso bovino demonstrou biocompatibilidade, capacidade osteocondutora e discreta perda de volume, preenchendo requisitos importantes do material ideal para reconstrução óssea. / Objective: To evaluate tissue response to inorganic bovine bone xenograft by histomorphological and histomorphometrical analyses. Material and methods: The bone grafts was obtained from cooled bovine rib 8 hours after slaughtering and were processed as follows: 60-minute immersion in hydrogen peroxide at room temperature, with changes at 15-minute intervals; 30-second immersion in hydrogen peroxide at 100ºC; immediate cooling with distilled water at temperatures ranging from 6º to 8ºC; rinsing in running distilled water for 6 hours; immersion in alcohol grades of 70º, 90º and 100ºGL (15-minute in each solution); autoclaving. Thereafter, 10 white New Zealand rabbits were distributed into two groups: Group I – graft inserted in the ear pavilion and Group II – graft inserted and fixed in the tibia. After 180 days, the animals were sacrificed by anesthetic overdose. Results: In Group I, the graft was in intimate contact with the subcutaneous tissue, while in Group II the graft was juxtaposed to the recipient site. Both groups presented medullar spaces filled with active bone marrow and newly formed bone. In addition, osteocytes were absent in the bovine bone graft and present in the newly formed bone, close to the medullar spaces. Conclusion: From the obtained results, the inorganic bovine bone xenograft showed biocompatibility.
125

Avaliação comparativa do processo de reparo do osso alógeno fresco congelado, em bloco, e do enxerto ósseo autógeno: análise histológica, histométrica e imunoistoquímica em coelhos

Garbin Júnior, Eleonor Álvaro [UNESP] 27 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-27Bitstream added on 2014-06-13T19:41:00Z : No. of bitstreams: 1 garbinjunior_ea_dr_araca.pdf: 1251895 bytes, checksum: 7b31a949d6b870eb13f7eecb1fdb04a6 (MD5) / Com a finalidade de recuperar rebordos alveolares atróficos para posterior reabilitação com implantes osseointegrados, além do enxerto ósseo autógeno, o osso alógeno fresco congelado recentemente tem sido empregado. O objetivo deste estudo foi analisar comparativamente o reparo dos enxertos ósseos autógenos e alógenos congelado em bloco, através de análise histológica, histométrica e imunoistoquímica em coelhos. Material e método: vinte um animais foram anestesiados para a realização da cirurgia experimental onde, na região de ângulo de mandíbula esquerdo foi fixado um bloco ósseo autógeno de 0,8 cm de diâmetro, utilizando-se parafuso, e no lado direito foi fixado, da mesma forma, um bloco ósseo tratado pelo Banco de Tecidos Músculo-Esquelético. Cinco animais de cada grupo foram sacrificados nos períodos de 15, 45, 120 e 180 dias. Os cortes histológicos foram corados pela hematoxilina e eosina e pela técnica de imunoistoquímica para avaliar atividades de reabsorção e neoformação óssea. Resultados: a análise histométrica mostrou não haver diferença estatística entre os grupos em relação à interface óssea leito receptor/enxerto ósseo aos 15 dias, contudo, analisando o bloco enxertado, notou-se maior revascularização, reabsorção e substituição óssea no grupo osso autógeno, fato este comprovado estatisticamente pela análise imunoistoquímica. Nos períodos tardios, o osso autógeno foi substituído em todas as amostras, enquanto no grupo do osso alógeno fresco congelado foi sempre possível encontrar osso desvitalizado junto ao parafuso de fixação. Conclusão: o processo de reparo apresentou maior dinâmica para o grupo enxerto ósseo autógeno em relação ao osso alógeno fresco congelado. A substituição do enxerto autógeno foi completa enquanto... / The autogenous bone graft and the freeze allogenic bone graft have being used to reconstruct atrophic alveolar ridge to allow the use of osteointegrated implants rehabilitation. The aim of this study was to compare the healing process of autogenous and allogenic bone graft using the histological, histometrical, imunoistochemical analyses in rabts. Material and Methods: twenty one animals had surgery done to allow fixation of 0.8 cm diameter of autogenous tibia bone graft on the left mandibular angle, and allogenic tibia bone graft on the right madibular angle. Five animals from each group were sacrificed at 15, 45, 120, and 180 postoperative days. The histological cuts were stained by hematoxilin and eosin and imunohistochemical technique to evaluate the bone formation and resorption. Results: the histometric analyses of bone formation betweem the bone graft interface and mandibular bone showed no statistical difference on the 15 days, but, the graft surface evaluation showed more revascularization, resorption and bone formation on the autogenous bone graft group and it was confirmed statiscialy by the imunoistochemical analyses. On the lastest groups (120 and 180 postoperative days), the autogenous bone was totally replaced but on the allogenic group it was possible to find non vital bone next to the fixation screw. Conclusion: the bone repair showed more dynamic activity on the autogenous graft group and it was totally replaced. The allogenic graft was incorporated but, on the latest sacrificed groups, it was not totally replaced.
126

Avaliação da reação tecidual frente aos cimentos MTA Ângelus® cinza e um MTA fotopolimerizável experimental: análise microscópica em alvéolos dentários de ratos

Costa, Mariana Machado Teixeira de Moraes [UNESP] 25 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-25Bitstream added on 2014-06-13T19:03:55Z : No. of bitstreams: 1 costa_mmtm_dr_araca.pdf: 1110079 bytes, checksum: 91b6d45dfad96a82f57a7802c12b0cb7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Para contornar algumas dificuldades de manipulação do agregado de trióxido mineral (MTA) convencional, um MTA fotopolimerizável vem sendo desenvolvido. Desta forma, o objetivo do presente estudo foi avaliar a resposta tecidual frente ao uso deste material. Para isso, 57 tubos de polietileno preenchidos com o MTA experimental e o MTA cinza foram implantados em alvéolos de ratos. Como grupo controle, foram implantados tubos vazios. Os animais foram sacrificados após 30, 60 e 90 dias, sendo realizada a análise microscópica dos cortes obtidos e corados com Hematoxilina e Eosina. Foi possível concluir que o MTA fotopolimerizável apresentou uma resposta semelhante ao MTA cinza, caracterizada pela ausência de uma inflamação severa e pela deposição de tecido mineralizado em contato com o material. / The aim of this study was to evaluate the tissue reaction to a Light Cured MTA or MTA Ângelus® gray. It was used 57 animals, which were divided in three groups. In the Control Group, empty tubes were inserted into the rat’s sockets immediately after extraction. In the other groups, the tubes were filled with Light Cured MTA or MTA Ângelus®. After 30, 60 and 90 days after the implantation, the animals were sacrificed and the right hemi-maxilas were removed and processed in laboratory to analyses on light microscopy, with embedding in paraffin, cut with 6μm thickness and stained with HE. It was possible to conclude that Light Cured MTA presented a similar response when compared to MTA Ângelus®, being characterized by a mild inflammatory response and dystrophic calcifications areas. Despite of a favorable healing process obtained with this new experimental MTA, further studies should be conducted to elucidate these material properties and confirm the present results.
127

Influência da adição de bioactive glass na liberação de íons do cimento de ionômero de vidro modificado por resina

Gwinner, Fernanda Pelógia Camargo [UNESP] 18 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-18Bitstream added on 2014-06-13T20:25:44Z : No. of bitstreams: 1 gwinner_fpc_dr_sjc.pdf: 429388 bytes, checksum: 8f66379f177aa22a57995cbad67ae92f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esse estudo in vitro avaliou o efeito da adição de diferentes concentrações e composições de bioactive glass (BAG) ao cimento de ionômero de vidro modificado por resina (CIVMR) (Fuji II LC) na liberação de íons Ca2+ e PO4 3- após a imersão em simulador de fluido corpóreo (SFC), comparando com o grupo controle, sem BAG. Foram utilizados 3 tipos de BAG: BAG65 (65mol% SiO2, 31mol% CaO, 4mol% P2O5), BAG75 (75mol% SiO2, 21mol% CaO, 4mol% P2O5), BAG85 (85mol% SiO2, 11mol% CaO, 4mol% P2O5), adicionados ao CIVMR nas proporções de 25%, 35% e 50%. O BAG foi misturado ao pó do CIVMR e misturado com o líquido resinoso do CIVMR. O material foi colocado numa matriz de PVC (5mm x 1mm) e polimerizado, entre laminas de vidro, durante 40s. As amostras foram armazenadas a 37°C, com 100% de umidade, durante 24h. Após esse período as amostras foram trituradas por meio de gral e pistilo e peneiradas para a obtenção de partículas menores que 90μm. A liberação dos íons Ca2+ e PO4 3- foi mensurada após 15min, 30min, 1h, 3h, 6h e 24h de imersão de 20mg de cada material em SFC, com 5 réplicas para cada condição experimental. Para a análise estatística, foi utilizada a área sob a curva (PPM x tempo). Os dados foram submetidos à ANOVA e testes de Dunnet e Tukey (!= 0,05). Os grupos contendo BAG65 liberaram significantemente mais Ca2+ não havendo diferença entre as diferentes concentrações de BAG adicionado. Os grupos contendo BAG75 e BAG85 apresentaram resultados semelhantes, sendo que aqueles com 25% de BAG foram os que apresentaram menores valores de liberação de Ca2+ após 24h de imersão. Com relação a liberação de íons PO4 3-, os grupos contendo BAG65 apresentaram maiores valores de área... / Bioactive restorative materials may stimulate the repair of tooth structure though the release of remineralization-aiding components including calcium and phosphate. The objective of this study was to measure the ion release from resin-modified bioactive glass ionomer cement (RMBGIC) containing various formulations of bioactive glass (BAG). Three types of BAG: BAG65 (65 mol% SiO2, 31 mol% CaO, 4 mol% P2O5), BAG75 (75 mol% SiO2, 21 mol% CaO, 4 mol% P2O5), BAG85 (85 mol% SiO2, 11 mol% CaO, 4 mol% P2O5) were prepared using sol-gel method, grounded, micronized, and mixed with GIC powder (Fuji II LC, GC) in the following proportions: 1:1, 1:2, 1:3. The mixed-ionomer powders were combined with standard RMGIC liquid (Fuji II LC, GC) and light cured (40 s; Ultra Lume LED, 1100 mW/cm2) in cylindrical disk molds (5 mm x 2 mm). The cured RMBGIC specimens were grounded and sieved to 100 !m and immersed (20 mg; n=5) in 3 ml of simulated body fluid (SBF), at 37°C for 1/4, 1/2, 1, 3, 6 and 24 hours with continuous agitation. Following centrifugation and decanting, the [Ca+2] and [HxPO4 3-x] in the SBF were measured using ion specific electrode and visible spectroscopy, respectively. The amount of ion release were statistically analyzed using ANOVA/Tukey ($= 0.05). The [PO4 3-] in SBF immediately increased for all RMBGICs. The ion release slowly decreased after 1 h, yet remained higher than the original SBF over the 24 h period. The [PO4 3-] in SBF for the control GIC continuously decreased. Overall, BAG65 > BAG75= BAG85 > GIC for [PO4 3-]. The [Ca2+] release increase initially for all RMBGICs, remaining with higher values than thecontrol GIC. Resin modified glass ionomer cement... (Complete abstract click electronic access below)
128

Análise da reação tecidual a cimentos endodônticos de óxido de zinco e eugenol, à base de resina epóxica e à base de resina metacrilato : estudo "in vivo"

Scarparo, Roberta Kochenborger January 2007 (has links)
O presente estudo objetivou comparar histologicamente, nos períodos de 7, 30 e 60 dias, as reações ocorridas no tecido conjuntivo subcutâneo de ratos a três cimentos endodônticos. Foi realizada a implantação de tubos de polietileno contendo um cimento endodôntico de óxido de zinco e eugenol (EndoFill), um cimento à base de resina epóxica (AH Plus), um cimento à base de resina metacrilato (EndoRez) e tubos vazios (grupo controle). Observou-se as características do componente celular inflamatório - atentando para a presença de neutrófilos, linfócitos, plasmócitos, eosinófilos, macrófagos e células gigantes - da condensação fibrosa e da formação de abscesso. Foi realizada análise estatística entre os grupos realizada por meio do teste de Friedman, complementado pelo teste de Wilcoxon. Já as comparações entre os períodos de 7, 30 e 60 dias foram realizadas pelo teste de Kruskall Wallis complementado pelo teste U de Mann-Whitney.Os resultados apontaram para maior intensidade da reação inflamatória promovida pelos cimentos EndoFill e EndoRez, especialmente no que se refere às características do infiltrado linfoplasmocitário e à presença de macrófagos, os quais se apresentaram em número estatisticamente superior aos demais grupos. A condensação fibrosa foi menos intensa nas amostras do cimento EndoFill, e a indução de abscesso foi bastante reduzida nos quatro grupos de estudo, não sendo observadas diferenças significativas. O AH Plus apresentou uma tendência à redução das características da reação inflamatória, ainda que estatisticamente não tenham sido observadas diferenças entre os períodos avaliados (7,30 e 60 dias). Já os cimentos EndoFill e EndoRez apresentaram uma tendência à manutenção da reação inflamatória por períodos mais longos. Apenas no grupo controle houve redução significativa das características da reação inflamatória ao longo dos três períodos experimentais. Tais observações tornam evidente a ausência, entre os materiais testados, de um cimento com características ideais de biocompatibilidade. / The purpose of this study was to make a histological comparison, over 7- 30- and 60-day periods, of subcutaneous conjunctive tissue reactions to three endodontic sealers in rats. Polyethylene tubes containing a zinc-oxide and eugenol sealer (EndoFill), an epoxyresin- based sealer (AH Plus), a methacrylate-resin-based sealer (EndoRez), together with empty tubes (control group) were implanted. The characteristics of the inflammatory cell component were observed for the presence of neutrophils, lymphocytes, plasmocytes, eosinophils, macrophages and giant cells, together with fibrous condensation and formation of tissue abscesses. The results indicated a greater intensity of inflammatory reaction caused by the EndoFill and EndoRez sealers, particularly in relation to the characteristics of lymphoplasmocytic infiltration, and the presence of macrophages, which were statistically more evident than in the other groups. Fibrous condensation was less intense in the EndoFill samples, and abscess induction was considerably reduced in the four study groups, with no significant differences observed. AH Plus presented a tendency for reducing the characteristics of the inflammatory reaction, although no statistical differences were noticed between the periods assessed (7, 30 and 60 days). The EndoFill and EndoRez sealers display a tendency for maintaining the inflammatory reaction for longer periods. Only the control group displayed a significant reduction in the characteristics of the inflammatory reaction over the three experimental periods. These observations demonstrate the absence of a sealer with ideal biocompatibility characteristics among the materials tested.
129

Avaliação da resposta tecidual a cimentos cirúrgicos: estudo histológico realizado em alvéolo dental de ratos

Saito, Célia Tomiko Matida Hamata [UNESP] 01 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-01Bitstream added on 2014-06-13T20:36:51Z : No. of bitstreams: 1 saito_ctmh_me_araca.pdf: 2585296 bytes, checksum: 906f8a2b41c7692531d4c62397618600 (MD5) / Universidade Estadual Paulista (UNESP) / Os materiais odontológicos estão presentes em todas as especialidades. Na periodontia, aliado a uma técnica cirúrgica criteriosa, os cimentos cirúrgicos são materiais que ocupam posição importante. A proposta deste estudo foi avaliar a intensidade da resposta inflamatória e a deposição óssea em alvéolos de ratos após o implante dos cimentos cirúrgicos Coe-pak®, Perio Bond® e Voco pac®. Seguindo a remoção dos incisivos superiores direitos de 84 ratos machos (Rattus norvegicus albinus, Wistar), implantou-se em cada alvéolo um tubo de polietileno dos quais 63 estavam preenchidos com os cimentos e os restantes 21 tubos estavam vazios, compondo o grupo controle. A avaliação histológica considerou o número de células inflamatórias, a neoformação angioblástica, a densidade de fibroblastos e a presença e localização da deposição de tecido ósseo nos períodos pós-operatórios de 7, 14 e 28 dias. A análise estatística dos dados obtidos foi realizada utilizando-se Análise de Variância e teste de Krukal-Wallis. No critério infiltrado inflamatório, aos 28 dias, houve diferença estática significativa (p<0,01) entre o cimento Voco pac® e o grupo controle. Quanto à presença e localização da deposição de tecido ósseo houve diferença no grupo controle, comparando os períodos de 7 e 28 dias (p<0,01). Na associação de todos os critérios avaliados, o cimento Perio Bond® apresentou resultado menos favorável, significativamente diferente (p<0,01) do grupo controle. Respeitadas as condições experimentais deste estudo, pode-se concluir que o cimento Voco pac® evidenciou aos 28 dias maior número de células inflamatórias; enquanto cimentos Coe-pak® e Perio Bond® demonstraram comportamentos semelhantes ao grupo controle e considerando-se a associação dos resultados de todos os critérios nos períodos analisados neste estudo, o cimento Perio Bond®... / The purpose of this investigation was to investigate the inflammatory tissue reaction and bone deposition in rat's dental sockets in the presence of three periodontal dressing (Coe-pak®, Perio Bond® e Voco pac®). After the exodontic removal of the right upper incisors of the eighty-four male rats, one polyethylene tube was implanted in each dental socket. Twenty one of these were empty and the other sixty-three tubes were fulfilled with periodontal dressings. The number of inflammatory cells, angioblastic neoformation, fibroblastic density and bone neoformation were evaluated after 7, 14 and 28 days. Significant differences (p<0.05) were observed in the number of inflammatory cells at 28 days, when Voco pac® was implanted. Considering bone neoformation, there was significant difference (p<0.01) between 7 and 28 days, in control group. When all events evaluated were associated, Perio Bond® showed the most severe response, which was staticcally different (p<0.01) from the control group. The following conclusions were obtained: after 28 days, Voco pac® presented at 28 days the greater number of inflammatory cells, while Coe-pak® and Perio Bond® periodontal dressings showed same number of the control group and when all events an periods of time were associated, Perio Bond® showed the most severe inflammatory response.
130

Reparação óssea de cavidades cirurgicamente criadas e preenchidas com uma associação de vidro bioativo e osso autógeno: análise histométrica e imunoistoquímica

Guskuma, Marcos Heidy [UNESP] 19 December 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-12-19Bitstream added on 2014-06-13T19:09:44Z : No. of bitstreams: 1 guskuma_mh_me_araca.pdf: 1219994 bytes, checksum: 484d9c888788d9dd3dad64af3c3a8f74 (MD5) / A proposta deste estudo foi avaliar a expressão das proteínas que participam do processo de reparo ósseo, nas fases de revascularização (VEGF), osteoindução (BMP2 e CBFA1) e mineralização (OCN), quando da utilização de uma associação do vidro bioativo e osso autógeno em proporção de 1:1 em defeitos criados em calvária de ratos. MATERIAIS E MÉTODOS: Para o presente estudo foram utilizados 40 ratos adultos machos (Rattus norvegicus albinus, Wistar) que receberam dois defeitos ósseos de 5 mm cada, em calvária. Os defeitos ósseos constituiram quatro grupos experimentais (n=10): Grupo CONT (reparação apenas com o próprio coágulo); Grupo ENX (defeitos preenchidos com OA removido do defeito contralateral); Grupo ENX VB (defeitos preenchidos com uma associação de vidro bioativo e osso autógeno 1:1); e Grupo VB (defeitos ósseos preenchidos com vidro bioativo). Os animais foram submetidos a eutanásia nos períodos de 7 e 30 dias pós-operatórios. RESULTADOS: O VB não alterou de forma significativa as reações celulares do reparo ósseo, no entanto, a presença do osso autógeno no defeito causou uma redução importante da expressão das proteínas estudadas. O Grupo ENX foi o que obteve a maior AON e o Grupo VB a menor. CONCLUSÕES 1) Em defeitos de tamanho crítico em calotas, o osso autógeno em bloco continua sendo o tratamento padrão ouro; 2) Para o tratamento destes defeitos, pode-se indicar a utilização dos vidros bioativos sem a necessidade de associação ao osso autógeno. / AIMS: The aim of this study is to evaluate the expression of the proteins that participate in the bone repair process, during the revascularization step (VEGF), osteoinduction (BMP2 and CBFA1) and mineralization (OCN), after the use of an association of bioactive glass and autogenous bone in 1:1 rate, in rats calvária defects. METHODS: 40 male adult rats (Rattus novergicus albinus, Wistar) received two calvarial defects created with 5mm diameter. The bone defects constituted 4 experimental groups (n=10): Control group (the defects were filled with blood clot), Graft Group (the defects were filled with autogenous bone removed from the contralateral defect), Graft and Bioactive Glass Group (the defects were filled with an association of bioactive glass and autogenous bone in 1:1 rate); and Bioactive Glass Group ( the bone defects were filled with bioactive glass). The animals were sacrificed at 7 and 30 days post operative periods. RESULTS: The bioactive glass did not alter, in a significant way, the cellular responses of the bone repair, otherwise, the presence of autogenous bone in the defect caused an important reduction in the expression of the studied proteins. The graft group achieved the better bone neoformed area and the bioactive glass achieved the smaller. CONCLUSIONS: 1. In the calvaria critical-size defects, the block autogenous bone is still the gold standard treatment; 2) For this defects treatment, bioactive glasses may be indicated without the autogenous bone association.

Page generated in 0.0888 seconds