• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 203
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 208
  • 208
  • 82
  • 79
  • 50
  • 38
  • 33
  • 29
  • 28
  • 28
  • 24
  • 21
  • 21
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

F1 protein fraction obtained from latex incorporated into CaP-materials improve critical-size defect bone repair in a concentration-dependent manner / A fração proteica F1 obtida do látex incorporado à biomateriais a base de CaP melhora o reparo defeitos ósseos de tamanho crítico de maneira dependente da concentração

Paini, Suelen 28 September 2018 (has links)
One strategy for bone regenerative engineering is to use matrices associated to osteogenic and angiogenic molecules to increase bone formation. The aim of the present study was to evaluate the efficacy of treatment of extensive cranial bone defects with the F1 protein obtained from latex adsorbed at different concentrations (0,01%, 0,025%, 0,05% e 1%) to two different bonesubstitutes biomaterials, deproteinized bovine bone (DBB) and biphasic calcium phosphate ceramics (pBCP) using a preclinical model in rats. Defects of 8-mm diameter were created in parietal bones of 72 rats filled with the pure biomaterial or carried with the different concentrations of F1 protein, in the microtomographic images a visual analysis of the microtomographic reconstructions of the skull through transverse, coronal and sagittal sections. Subsequently, the segmentation of the defect in the reconstructions will be done through an image processing algorithm to quantify the parameters. Analyzing, in the BP-G group, the total volume of bone (TV), in the CSBD-CG group, the total volume of new bone (TV-NB), and in the treated groups, the total volume of the grafted region (TV/GR), the total volume of new bone (TV-NB) and biomaterials (TV/DBB and TV/pBCP). In tissue sections stained with Hematoxylin and Eosin a descriptive histological analysis was performed to verify the tissue response to treatment with F1 protein and its association with osteoconductive biomaterial and correlate it with the histomorphometric determination to obtain percent values and volume of neoformed bone tissue, biomaterial, bone marrow and soft tissue. In the characterization of DBB and pBCP biomaterials, it was performed through the combined analytical methodology by SEM and SDD-EDS, to analyze external morphology and elemental chemical composition. All the results were compared between the groups by the ANOVA variance analysis and the Tukey tests at the 5% level of significance (Statistica v.5.1, StatSoft). After 12 weeks, defects treated with biomaterials without F1 presented greater bone formation in relation to the control group. The association of 0.025% and 0.05% of F1 plus DBB showed higher bone formation (32.6% and 25.1%, respectively) when compared to pBCP, being 19.3% and 15.1%, respectively. We conclude that the stimulation of angiogenesis and osteogenesis depends on its concentration of F1e and the physicochemical properties of the carrier material. / Uma estratégia da engenharia regenerativa óssea é usar matrizes associadas a moléculas osteogênicas e angiogênicas para aumentar a formação óssea. O objetivo do presente estudo foi avaliar a eficácia do tratamento de defeitos ósseos cranianos extensos com a proteína F1 obtida do látex adsorvido em diferentes concentrações (0,01%, 0,025%, 0,05% e 1%) a dois diferentes biomateriais ósseo-substitutos, osso bovino desproteinizado (DBB) cerâmica de fosfato de cálcio bifásica (pBCP) utilizando um modelo pré-clínico em ratos. Defeitos de 8 mm de diâmetro foram criados nos ossos parietais de 72 ratos preenchidos com o biomaterial puro ou carregados com as diferentes concentrações da proteína F1, nas imagens microtomográficas uma análise visual das reconstruções microtomográficas do crânio através de cortes transversais, coronais e sagitais. Subsequentemente, foi feito segmentação do defeito nas reconstruções através de algoritmo de processamento de imagem para quantificação dos parâmetros. Analisando, no grupo BP-G, o volume total de osso (TV), no grupo CSBD-CG o volume total de osso novo (TV-NB), e nos grupos tratados, o volume total da região enxertada (TV-GR), volume total de osso novo (TV-NB) e biomaterial (TV-DBB e TV-pBCP). Nos cortes teciduais corados pela Hematoxilina e Eosina foi realizado uma análise histológica descritiva para verificar a resposta tecidual frente ao tratamento com a proteína F1 e a sua associação com biomaterial osteocondutor e correlaciona-la com a determinação histomorfométrica para a obtenção dos valores percentuais e de volume de tecido ósseo neoformado, biomaterial, medula óssea e tecido conjuntivo. Na caracterização dos biomaterias DBB e pBCP, foi realizado através da metodologia analítica combinada por SEM e SDD-EDS, para analisar morfologia externa e composição química elementar. Todos os resultados foram comparados entre os grupos pela análise de variância ANOVA e o tests de Tukey ao nível de significância de 5% (Statistica v.5.1, StatSoft). Após 12 semanas, defeitos tratados com biomateriais sem F1 apresentaram maior formação óssea em relação ao grupo controle. A associação de 0,025% e 0,05% de F1 mais DBB mostraram maior formação óssea (32,6% e 25,1%, respectivamente) quando comparados com pBCP, sendo 19,3% e 15,1%, respectivamente.Nós concluímos que, a estimulação da angiogênese e osteogênese depende de sua concentração de F1e das propriedades físico-químicas do material carreador.
82

Estudo do processo de reparo ósseo em função de quatro biomateriais. Avaliação histomorfológica em tíbia de coelhos / Study of bone repair process in function of four biomaterials. Microscopy evaluation in rabbit tibias

Cavenago, Bruno Cavalini 23 May 2011 (has links)
Este estudo avaliou o processo de reparo ósseo em cavidades cirúrgicas de tamanho não crítico, quando preenchidas por diferentes biomateriais. Um defeito ósseo de 5 mm de diâmetro por 8mm profundidade foi criado em cada metáfise tibial de 27 coelhos machos. Foram estabelecidos 4 grupos com 12 cavidades por material. As cavidades foram preenchidas com matriz óssea bovina inorgânica, GenOx Inorg® (grupo 1), matriz óssea bovina orgânica, GenOx Org® (grupo 2), matriz óssea bovina composta, GenMix® (grupo 3) e sulfato de cálcio di-hidratado (Grupo 4). Adicionalmente, seis cavidades preenchidas com coágulo sanguíneo foram utilizadas como controle (grupo 5). Os animais foram mortos após 30, 60 e 90 dias e as amostras coletadas foram submetidas ao processamento histotécnico para obter cortes de 5 m de espessura, corados com hematoxilina e eosina. Foram realizadas análises histomorfológica descritiva e histomofométrica, que consistiu na mensuração da área de tecido ósseo neoformado. Os dados obtidos foram submetidos ao teste estatístico de Kruskal-Wallis e Dunn. Aos 30 e 60 dias a área de tecido ósseo neoformado ocorreu de forma semelhante entre todos os grupos (P > 0,05). No período de 90 dias houve diferença significativa entre os grupos 2 e 4, bem como entre os grupos 4 e 5. Ao realizar a análise estatística de cada grupo em função dos 3 períodos experimentais, constatou-se que nos grupos 1, 2 e 3 a área de tecido ósseo neoformado aos 30 dias foi menor (P < 0,05) em relação a 60 e 90 dias. No grupo 4, ocorreu diferença significativa entre os períodos de 30 e 90 dias, já no grupo 5 houve diferença significante ao comparar 30 e 60 dias. Com base na microscopia observamos que os biomateriais estudados não inibiram o processo de reparo; o GenOx Inorg e a matriz inorgânica presente no GenMix exibiram características morfológicas de propriedade osteocondutora, mais intensa no primeiro grupo. O GenOx Org e o sulfato de cálcio di-hidratado apresentaram-se completamente reabsorvidos aos 30 dias. Foi possível concluir que os valores neoformativos proporcionados pelo GenMix não foram significativamente superiores, àqueles obtidos pelo GenOx Inorg, GenOx Org e sulfato de cálcio di-hidratado. Os diferentes biomateriais utilizados não apresentaram resultados superiores ao coágulo sanguíneo, exceto o sulfato de cálcio di-hidratado aos 90 dias. / This study evaluated the bone healing process in non-critical surgical cavity size, when grafted with different biomaterials. A 5mm wide and 8mm long defect were created in each tibial metaphysis of 27 male rabbits. Four groups of 12 cavities per material were established. The cavities were filled with deproteinized bovine bone, GenOx Inorg ® (group 1), demineralized bovine bone, GenOx Org® (group 2), composite bovine bone, GenMix® (group 3) and di-hydrate calcium sulfate (group 4). Additionally 6 cavities were filled with blood clot for control purposes (group 5). At 30, 60 and 90 days after surgery the animals were killed and the grafted areas were submitted to histologically process to obtain a 5 m thickness sections and stained with hematoxylin and eosin. The specimens were proceeded to descriptive and quantitative microscopic analysis, by measuring the area of new formed bone. The results were statistically analyzed by the Kruskal-Wallis and Dunn tests. At 30 and 60 days the area of new bone formation was similar among all groups (P > 0,05). In 90 days period there was a significant difference between groups 2 and 4, as well as groups 4 and 5. Performing the statistical analysis of each group in relation to the 3 experimental periods, it was found that in groups 1, 2 and 3 the area of new bone formed at 30 days was lower (P < 0,05) than 60 and 90 days. There was a significant difference in group 4 comparing the periods 30 and 90 days and in group 5 between 30 and 60 days. Based on microscopy findings we observed that the biomaterials studied did not inhibit the repair process; the GenOx Inorg and inorganic matrix present in GenMix exhibited morphological characteristics of osteoconductive property, more intense in the first one. The GenOx Org and di-hydrate calcium sulfate were completely reabsorbed within 30 days. It was concluded that the values of new bone formed area provided by GenMix were not significantly higher than obtained by GenOx Inorg, GenOx Org and di-hydrate calcium sulfate. The different biomaterials used did not show better results than blood clot, except di-hydrate calcium sulfate at 90 days.
83

Guarda de material biológico em biorrepositórios : implantação de protocolo no Hospital Universitário da Universidade Federal do Maranhão / HU-UFMA

Güttler, Maria Cláudia Santos January 2018 (has links)
A prática de colecionar material biológico humano na forma de Biorrepositórios (coleção de material biológico humano, coletado e armazenado ao longo da execução de um projeto de pesquisa específico) se tornou essencial para o avanço da pesquisa clínica. Contudo, normativas nacionais e internacionais recomendam a utilização de uma padronização mínima nas diversas práticas que abrangem a manipulação, gerenciamento e armazenamento de tais amostras e suas informações associadas de modo a garantir a qualidade dos resultados das pesquisas, ao mesmo tempo assegurar os padrões éticos e legais, respeitando o princípio da dignidade humana. Nesse contexto, o presente trabalho teve como objetivo caracterizar os setores de pesquisa do HU-UFMA (Hospital Universitário da Universidade Federal do Maranhão/HU-UFMA) que armazenam Biorrepositórios, quanto aos recursos humanos, estrutura física e padrões técnicos existentes, bem como desenvolver os Procedimentos Operacionais Padrão (POP’s) para manipulação e guarda das amostras biológicas pertencentes á estes Biorrepositóriose e outros que poderão vir a ser cirados. Para cumprir tais objetivos foram feitas visitas aos setores do hospital aonde são desenvolvidas as pesquisas; e aplicação de questionário com os Pesquisadores Responsáveis pelos grupos de pesquisa e com os Gestores dos setores de pesquisa na instituição. Os resultados dos questionários apontaram que alguns setores de pesquisas não contêm, e outros, estão em fase de desenvolvimento de seus POP’s para coleta, manipulação, gerenciamentos e guarda de Biorrepositórios, e que alguns grupos de pesquisas possuem, de forma isolada, POP’s para alguma das etapas de manipulação das amostras biológicas de seus Biorrepositórios. Foram identificados, ainda, os materiais biológicos que compõem os Biorrepositórios dos estudos realizados na instituição. A partir daí, realizou-se consultas a alguns dos POP’s existentes nos grupos de pesquisas e POP’s assistenciais de um dos setores estudado, para um melhor embasamento sobre os métodos utilizados nas pesquisas da instituição, além das diretrizes nacionais e internacionais sobre o tema abordado. O resultado foi a elaboração de POP’s para coleta, processamento e armazenamento das coleções de Biorrepositórios armazenados nos setores de pesquisas; elaboração de um manual de coleta, processamento, armazenamento e descarte das amostras visando à criação de Biorrepositórios; criação de formulários para registro das variáveis pré-analíticas existentes nas etapas de manipulação e guarda das amostras; e criação de modelos de formulários para cadastro do participante da pesquisa e de amostras armazenadas, no hospital. / The practice of collecting human biological material in the form of bio-repositories (collection of human biological material, collected and stored throughout the execution of a specific research project) has become essential for the advancement of clinical research. However, national and international regulations recommend the use of a minimum standardization in the various practices that cover the handling, management and storage of such samples and their associated information in order to guarantee the quality of the results of the research, at the same time assuring the ethical and respecting the principle of human dignity. In this context, the objective of the present study was to characterize the research sectors of the HU-UFMA (University Hospital of the Federal University of Maranhão / HU-UFMA) that store Biorrepositories in terms of human resources, physical structure and existing technical standards, as well as to develop the Standard Operating Procedures (SOPs) for manipulation and storage of the biological samples belonging to these bio-repositories and others which may be drawn. In order to fulfill these objectives visits were made to the sectors of the hospital where the research is carried out; and questionnaire application with the Researchers Responsible for the research groups and with the managers of the research sectors in the institution. The results of the questionnaires pointed out that some research sectors do not contain, and others, are in the development phase of their POPs to collect manipulation, management and custody of bio-repositories, and that some research groups have, in isolation, POP's for some steps of manipulating the biological samples of their bio-repositories. It was also identified the biological materials that make up the bio-repositories of the studies carried out at the institution. From then on, consultations were carried out with some of the existing POPs in the research groups and welfare POPs of one of the studied sectors, for a better basis on the methods used in the research of the institution, besides the national and international guidelines on the subject addressed. The result was the elaboration of POP's for the collection, processing and storage of the collections of bio-repositories stored in the research sectors; preparation of a manual for the collection, processing, storage and disposal of samples for the creation of bio-repositories; creation of forms for recording the pre-analytical variables in the sample handling and storage stages; and creation of template forms for registration of the research participant and of stored samples in the hospital.
84

Corpos compósitos de poli(metacrilato de metila) com microfibra de biovidro e poros para reparo de defeitos ósseos / Composite samples of poly(methyl methacrylate) with bioglass microfiber and pores to repair bone defects

Lourdes Cristina de Albuquerque Haach 06 March 2015 (has links)
Este trabalho está baseado no desenvolvimento do compósito poli(metacrilato de metila) (PMMA) microfibra de biovidro 45S5® (BV) com porosidade para aplicação direcionada a implantes ósseos. O PMMA é um material do tipo bioinerte amplamente utilizado na fabricação de implantes. O biovidro 45S5® é um biomaterial bioativo classe-A, que significa ser capaz de integração com tecidos moles e ósseos. O presente trabalho objetiva a conjugação das propriedades destes dois materiais em um conceito que introduz microfibra de biovidro 45S5® e porosidade em uma matriz de PMMA na busca de um material com elevada osteointegração e que permita a manufatura de implantes com adequada resistência a carregamentos mecânicos. Foram manufaturados e avaliados fisicamente e in vivo corpos de prova de PMMA com introdução de 20% de microfibra de biovidro (densos e porosos a 80%), corpos de PMMA com introdução de hidroxiapatita (densos e porosos a 80%) e de PMMA (densos e porosos a 80%) para controle. Foram realizados testes mecânicos de compressão e de flexão a três pontos para medidas de resistência e rigidez. Também foram realizadas medidas da microdureza Vickers e da densidade das amostras. Os resultados médios obtidos da tensão de escoamento e módulo elástico para os corpos de prova com introdução de 20% de microfibra de biovidro nos ensaios de compressão foram de 44 MPa e 1403 MPa respectivamente para as amostras densas e de 8 MPa e 13 MPa para as amostras porosas e nos ensaios de flexão foram de 48 MPa e 8129 MPa para os corpos densos e de 5 MPa e 97 MPa para os corpos porosos. A modelagem matemática a partir dos resultados permite a determinação antecipada da formulação para o atendimento específico de cada proposta de implante. Os implantes ensaiados in vivo com adição de microfibra de Biovidro 45S5® foram os que apresentaram os melhores resultados em integração óssea e controle da inflamação local. / This work is based on the development of poly(methyl methacrylate) (PMMA) - bioglass 45S5® microfibers composite with porosity for bone implants application. PMMA is a bioinert material widely used in the manufacture of biological implants. The 45S5® bioglass is a bioactive class-A biomaterial which indicates ability to integrate with bone and soft tissues. The present study aims to combine the properties of these two materials on a concept that introduces bioglass 45S5® microfibers and porosity in a matrix of PMMA in order to find a material with high bone integration and capable of manufacture implants with adequate resistance to mechanical loads. Samples of PMMA with the introduction of 20% of bioglass microfiber (dense and 80% of porous), PMMA with introduction of hydroxyapatite (dense and 80% of porous), and PMMA (dense and 80% of porous) for control were fabricated and evaluated both physically and in vivo. Mechanical tests such as compression and three points bending have been performed for measurements of strain and stiffness. Measurements of Vickers microhardness and density of the samples also were performed. The average results of yield stress and elastic modulus for the samples with the introduction of 20% microfiber bioglass in compression tests were 44 MPa and 1403 MPa respectively for dense samples and 8 MPa and 13 MPa for porous samples and in bending tests were 48 MPa and 8129 MPa for dense bodies and 5 MPa and 97 MPa for the porous bodies. The mathematical modeling based on the results allows the early determination of the formulation to meet the specific needs of each implant proposal. The implants tested in vivo with addition of 45S5® bioglass microfiber presented the best results in bone integration and control of local inflammation when compared with all the other groups with the scaffold presence.
85

Utilização de blendas poliméricas no reparo de defeitos cranianos de ratos / Use of polymer blends in the repair of cranial defects in rats

Munhoz, Marcelo de Azevedo e Souza 13 December 2013 (has links)
Na clínica ortopédica e traumatológica existem diversos desafios clínicos envolvendo as extensas perdas de tecido ósseo, relacionados primordialmente com causas traumáticas, tumorais, congênitas e infecciosas. No tratamento, podem ser utilizados os enxertos autólogos, homólogos, xenólogos e os enxertos periostais. Os substitutos sintéticos, conhecidos como biomateriais, também são uma boa alternativa. O objetivo deste trabalho foi avaliar o processo de neoformação óssea durante o reparo de defeitos ósseos, provocados experimentalmente no crânio de animais enxertados com blenda polimérica, constituída de colágeno de tendão bovino e quitosana associada à hidroxiapatita. Foram utilizados 30 ratos (Rattus norvegicus, Wistar), machos, com peso aproximado de 330 gramas e 4 meses de idade. Os animais foram submetidos ao procedimento cirúrgico para a criação de defeito ósseo no osso parietal esquerdo da calota craniana para o preenchimento com os biomateriais pesquisados. Foram divididos em 3 grupos com 10 animais cada, sendo um grupo controle sem a implantação de biomaterial, outro com implantação de blenda de colágeno e quitosana e o último com a utilização desta blenda em associação com hidroxiapatita. Cada grupo foi subdividido em dois subgrupos com 5 animais de acordo com o tempo do sacrifício pós-operatório, sendo com 3 semanas nos grupos de G1 a G3 e com 8 semanas de G4 a G6. Após o sacrifício, as calotas cranianas foram retiradas para foto documentação macroscópica e exames radiográficos. Em seguida, as amostras foram submetidas aos procedimentos histotécnicos de confecção das lâminas para avaliação histológica da neoformação óssea no local cirúrgico. A pesquisa foi aprovada pelo comitê de ética da Faculdade de Medicina de Jundiaí, protocolo nº 301/12. As análises macroscópicas e radiográficas demonstraram a biocompatibilidade das blendas utilizadas. Histologicamente, houve discreta neoformação óssea em continuidade com as margens da lesão óssea, porém predominou a presença de tecido conectivo na área cirúrgica. As blendas poliméricas apresentaram biocompatibilidade com o tecido receptor, porém com baixa capacidade osteogênica devido à permanência do defeito ósseo. Não houve a sua osteointegração em virtude da presença de tecido conectivo em grande quantidade e adjacente ao implante. / In orthopedics and traumatology there are several clinical challenges involving extensive bone loss, primarily related to trauma, tumors, congenital and infectious diseases. These conditions can be usually treated by autologous, periosteal, homologous and xenologous grafts. A good alternative is to use synthetic biomaterials as substitute. The aim of this study was to evaluate the process of bone formation during repair of bone defects experimentally induced in animals skull, grafted by a polymer blend consisting of bovine tendon collagen and chitosan associated with hydroxyapatite. A total of 30 rats (Rattus norvegicus, Wistar) male, weighing approximately 330 grams and 4 months old was used. The animals underwent the surgical procedure for the creation of defect in the left parietal bone of the skull. They were divided into 3 groups of 10 animals each: a control group without biomaterials implantation, another with a blend of collagen and chitosan and the latest with the use of this blend in association with hydroxyapatite. Each group was subdivided into two subgroups of 5 animals according to the sacrifice schedule after surgery. The groups were named G1, G2 and G3 when the sacrifice occurred after 3 weeks postoperative and G4, G5 and G6 after eight weeks. After sacrifice, the calvarias were removed for macroscopic photo documentation and radiographic examinations. Then the samples were subjected to histotechnical procedures for histological evaluation of new bone formation at the surgical site. The study was approved by the ethics committee of the Faculdade de Medicina de Jundiaí (protocol # 301/12). The macroscopic and radiographic analysis demonstrated the biocompatibility of the blends. Histologically, there was a slight bone formation in continuity with the edges of the bone lesion, but the predominant presence of connective tissue in the surgical area. The polymer blends showed biocompatibility with the host tissue but low osteogenic capacity due to the bone defect. There was no osseointegration due to the presence of connective tissue in large quantity adjacent to the implant.
86

Corpos compósitos de poli(metacrilato de metila) com microfibra de biovidro e poros para reparo de defeitos ósseos / Composite samples of poly(methyl methacrylate) with bioglass microfiber and pores to repair bone defects

Haach, Lourdes Cristina de Albuquerque 06 March 2015 (has links)
Este trabalho está baseado no desenvolvimento do compósito poli(metacrilato de metila) (PMMA) microfibra de biovidro 45S5® (BV) com porosidade para aplicação direcionada a implantes ósseos. O PMMA é um material do tipo bioinerte amplamente utilizado na fabricação de implantes. O biovidro 45S5® é um biomaterial bioativo classe-A, que significa ser capaz de integração com tecidos moles e ósseos. O presente trabalho objetiva a conjugação das propriedades destes dois materiais em um conceito que introduz microfibra de biovidro 45S5® e porosidade em uma matriz de PMMA na busca de um material com elevada osteointegração e que permita a manufatura de implantes com adequada resistência a carregamentos mecânicos. Foram manufaturados e avaliados fisicamente e in vivo corpos de prova de PMMA com introdução de 20% de microfibra de biovidro (densos e porosos a 80%), corpos de PMMA com introdução de hidroxiapatita (densos e porosos a 80%) e de PMMA (densos e porosos a 80%) para controle. Foram realizados testes mecânicos de compressão e de flexão a três pontos para medidas de resistência e rigidez. Também foram realizadas medidas da microdureza Vickers e da densidade das amostras. Os resultados médios obtidos da tensão de escoamento e módulo elástico para os corpos de prova com introdução de 20% de microfibra de biovidro nos ensaios de compressão foram de 44 MPa e 1403 MPa respectivamente para as amostras densas e de 8 MPa e 13 MPa para as amostras porosas e nos ensaios de flexão foram de 48 MPa e 8129 MPa para os corpos densos e de 5 MPa e 97 MPa para os corpos porosos. A modelagem matemática a partir dos resultados permite a determinação antecipada da formulação para o atendimento específico de cada proposta de implante. Os implantes ensaiados in vivo com adição de microfibra de Biovidro 45S5® foram os que apresentaram os melhores resultados em integração óssea e controle da inflamação local. / This work is based on the development of poly(methyl methacrylate) (PMMA) - bioglass 45S5® microfibers composite with porosity for bone implants application. PMMA is a bioinert material widely used in the manufacture of biological implants. The 45S5® bioglass is a bioactive class-A biomaterial which indicates ability to integrate with bone and soft tissues. The present study aims to combine the properties of these two materials on a concept that introduces bioglass 45S5® microfibers and porosity in a matrix of PMMA in order to find a material with high bone integration and capable of manufacture implants with adequate resistance to mechanical loads. Samples of PMMA with the introduction of 20% of bioglass microfiber (dense and 80% of porous), PMMA with introduction of hydroxyapatite (dense and 80% of porous), and PMMA (dense and 80% of porous) for control were fabricated and evaluated both physically and in vivo. Mechanical tests such as compression and three points bending have been performed for measurements of strain and stiffness. Measurements of Vickers microhardness and density of the samples also were performed. The average results of yield stress and elastic modulus for the samples with the introduction of 20% microfiber bioglass in compression tests were 44 MPa and 1403 MPa respectively for dense samples and 8 MPa and 13 MPa for porous samples and in bending tests were 48 MPa and 8129 MPa for dense bodies and 5 MPa and 97 MPa for the porous bodies. The mathematical modeling based on the results allows the early determination of the formulation to meet the specific needs of each implant proposal. The implants tested in vivo with addition of 45S5® bioglass microfiber presented the best results in bone integration and control of local inflammation when compared with all the other groups with the scaffold presence.
87

Tratamento regenerativo periodontal de defeitos infra-ósseos de duas ou três paredes realizados em animais e humanos, utilizando a membrana reabsorvível de osso cortical bovino (GEN-DERM), osso inorgânico bovino (GEN-OX) e ácido cítrico com / Periodontal regenerative treatment of two or three walls-defects intra bony made in animals and humans, using anorganic bovine bone, resorbable membrane of bovine cortical bone and citric acid with tetracycline

Nahás, Ana Lúcia Raphaelli 13 February 2004 (has links)
Este estudo teve como objetivo avaliar a biocompatibilidade em coelhos e a regeneração periodontal em defeitos intra-ósseos em humanos, utilizando o osso inorgânico bovino (Gen-Ox). Cinco grupos de coelhos, contendo 5 em cada um deles, foram sacrificados nos períodos de 30, 60, 90, 180 e 270 dias, após a colocação do enxerto ósseo. No estudo em humanos, a amostra constou de 10 indivíduos com idade entre 25 e 60 anos, apresentando um par de defeitos intra-ósseos, localizados no mesmo arco dentário em dentes do mesmo tipo (pré-molares ou molares) e com perda de inserção (PI) 5mm. Em cada indivíduo, o lado teste foi tratado na superfície radicular com aplicação de ácido cítrico com tetraciclina, preenchido o defeito com osso inorgânico bovino (Gen-Ox), e adaptada a membrana reabsorvível de osso cortical bovino (Gen-Derm), enquanto o lado controle foi tratado na superfície radicular com aplicação de ácido cítrico com tetraciclina e adaptada a membrana reabsorvível (Gen-Derm). Houve uma redução significante no nível de inserção nos dois grupos, quando avaliados na comparação entre os períodos pré-operatórios e aos seis meses de pós-operatório, tendo o grupo teste mostrado uma melhora significante quando comparado ao grupo controle (teste t pareado, p=0,038). Foram feitos controles radiográficos padronizados de ambos os grupos para a obtenção das medidas individuais, com posterior análise estatística das variações das medidas. MEDIDA 1, da Junção Cemento Esmalte até o final do ápice da raiz (J.C.E.-A). MEDIDA 2, da J.C.E.- RT (até o início da radiotransparência). MEDIDA 3, da J.C.E.-D (até o final do defeito). As variações ocorridas no período entre a radiografia inicial e 6 meses alcançaram significância estatística somente para a medida 1 (p=0,03), radiografia inicial e 12 meses para as medidas 1 (p=0,043) e 3 (p=0,001) pelo teste de Tukey. Conclui-se que na avaliação histológica em coelhos, nos períodos de 3 a 9 meses, ocorreu a remodelação óssea e a estabilização do processo de reparo. Em humanos, houve uma significância estatística nos períodos de 1 a 6 meses (grupo teste), tanto na sondagem quanto na avaliação radiográfica, e no período de 6 a 12 meses, não houve diferença significante entre os grupos. / This study aimed at evaluating the biocompatibility in rabbits and the periodontal regeneration of intra-bony defects in humans, utilizing a bovine inorganic bone (Gen-Ox). Five groups of rabbits, containing 5 in each group, were sacrificed in the periods of 30, 60, 90, 180 and 270 days, following the bone graft. In the study in humans, the sample was comprised of 10 individuals in the age range 25 - 60 yrs, presenting a pair of intra-bony defects, located in the same dental arch, in teeth of the same type (pre-molars or molars) and with an insertion loss (IL) 5mm. In each individual, the test side was treated on the root surface, with the application of citric acid with tetracycline and the bone defect filled with bovine inorganic bone (Gen-Ox), being the resorbable membrane of bovine cortical bone (Gen-Derm) adapted, while the control side was treated on the root surface, with the application of citric acid with tetracycline, being the resorbable membrane (Gen-Derm) adapted. There was a significant reduction in the insertion level in the two groups, when evaluated between the pre-surgical periods and at six months, postoperatively, the test group showing a significant improvement as compared to the control (paired t test, p=0.038). Standardized radiographic controls were made of both groups, so as to obtain individual measurements, followed by statistical analysis of the measurement variations. MEASUREMENT 1, from the cementoenamel junction up to the end of the root apex (J.C.E.-A). MEASUREMENT 2, from the J.C.E.-RT (up to the beginning of radio-transparency). MEASUREMENT 3, from the J.C.E.-D (up to the end of defect). The variations occurred in the period between the initial radiography and 6 months, had statistical significance only for measurement 1 (p=0.03), initial radiography and 12 months for measurements 1 (p=0.043) and 3 (p=0.001), by Tukey´s test. It was concluded that in the histological evaluation of rabbits, in the periods of 3 to 9 months, there was a bone remodeling and stabilization of the repair process. In humans, there was a statistical significance in the periods of 1 to 6 months (test group), both in probing and radiographic evaluation, and in the period 6 to 12 months, no significant difference was seen between the groups.
88

Caracterização físico-quimica e avaliação de biocompatibilidade de biovidros estudo laboratorial e histomorfométrico em ratos

Cruz, Ariadne Cristiane Cabral da 17 June 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:23Z (GMT). No. of bitstreams: 1 AriadneCristiane.pdf: 1142679 bytes, checksum: b75266aff500589fbbff70e1db04f74b (MD5) Previous issue date: 2004-06-17 / The purpose of this study was to evaluate physic-chemical characteristics and the biocompatibility of the bioglass, developed by the UEPG Chemistry Department, (UEPG Bioglass) and compare it with the PerioGlas® e Biogran®. The physicchemical characterization was made by scanning electron microscopy (SEM) (size and morphology of particles); scanning electron microscopy/energy dispersive X Ray (MEV/EDAX) (chemical elements); X Ray diffractometry (DRX) (structure); X Ray fluorescence (FRX) (chemical elements) For the biocompatibility test was used 100 rats: Gl-PerioGlas® - 25 animals; Gll – Biogran® - 25 animals; Glll – Biovidro UEPG – 25 animals; GIV – Control (surgical procedure without implantation of biomaterial) – 25 animals. The animals were evaluated at 7, 15, 21, 45 and 60 days. It was used histomorphometric analysis to determine the size of inflammatory reaction, size of granules, the presence and quantity of polymorphonuclear cells (PMN), mononuclear (MN) and fibroblast (F). The results shown that the particles of the three materials were irregular with superficial roughness. The medial size of PerioGlas® granules was 222,00±40,64 µm. The Biogran® granules with 385.09±68.51µm. And the UEPG Bioglass was 102.86±36.22µm. There was significant difference in the size of granules (p<0.001-ANOVA). The three samples presented calcium, oxygen, sodium, phosphorus and silica, aggregated on silica oxide, sodium oxide, calcium oxide and phosphorus oxide. The materials were no crystalline and with crystalline points in their surfaces. There was significant difference on size of inflammatory reaction between groups, times and interaction (group*time) (p<0.001). There was not significant difference between on the count of MN between groups (p=0.117), there was difference between times (p<0.001) and interaction (p=0.022). There was significant difference (p<0.001) on the count of PMN between the times, groups and interaction. There was not significant difference on the count of F between the groups (p=0.131) and interaction (p=0.665), with significant difference between the times (p=0.008). There was significant difference on granules size between the groups, time and interaction (p<0.001). It was concluded that the three materials were biocompatible and bioreabsorbable, without sign of osteoinducture capacity. / O presente trabalho se propôs a avaliar as características físico-químicas e a biocompatibilidade do biovidro desenvolvido pelo departamento de Química da UEPG (Biovidro UEPG) e compará-lo com o PerioGlas® e Biogran®. Realizou-se a caracterização físico-química através da microscopia eletrônica de varredura (MEV) (tamanho e morfologia das partículas); microscopia eletrônica de varredura/ energia dispersiva de Raios X (MEV/EDX) (elementos químicos); difratometria de Raios X (DFR) (estrutura); fluorescência de Raios X FRX (elementos químicos). Para o teste de biocompatibilidade utilizou-se 100 ratos, sendo: GI- PerioGlas® - 25 animais; GIIBiogran ® - 25 animais; GIII- Biovidro UEPG - 25 animais; GIV- Controle (procedimento cirúrgico sem implantação do biomaterial) - 25 animais. Avaliou-se os animais em 7, 15, 21, 45 e 60 dias. Através de histomorfometria determinou-se o tamanho da reação inflamatória, tamanho dos grânulos, presença e quantidade de células polimorfonuclear (PMN), mononuclear (MN) e fibroblasto (F). Os resultados mostraram que as partículas dos três materiais apresentaram-se não uniformes e com rugosidade superficial. Os grânulos de PerioGlas® apresentaram-se com tamanho médio de 222,00±40,64µm. O Biogran® com 385,09±68,51µm. E o Biovidro-UEPG com 102,86±36,22µm. Houve diferença significativa no tamanho dos grânulos (p<0,001- ANOVA). Identificou-se nas três amostras cálcio, oxigênio, sódio, fósforo e sílica, agrupados em óxido de sílica, óxido de sódio, óxido de cálcio e óxido de fósforo. Os materiais mostraram-se não cristalinos e com pontos de cristalização. Houve diferença significativa no tamanho da reação inflamatória entre os grupos, tempos e interação (grupo*tempo) (p<0,001). Na contagem de MN não houve diferença significativa entre os grupos (p=0,117), havendo entre os tempos (p<0,001) e interação (p=0,022). Houve diferença significativa (p<0,001) na contagem de PMN entre os tempos, grupos e interação. A contagem de F não mostrou diferença significativa entre os grupos (p=0,131) e interação (p=0,665), havendo diferença entre os tempos (p=0,008). Houve diferença significativa no tamanho dos grânulos entre os grupos, tempo e interação (p<0,001). Concluiu-se que os três materiais apresentaram-se biocompatíveis e bioreabsorvíveis, sem indício de capacidade osteoindutora.
89

Tratamento regenerativo periodontal de defeitos infra-ósseos de duas ou três paredes realizados em animais e humanos, utilizando a membrana reabsorvível de osso cortical bovino (GEN-DERM), osso inorgânico bovino (GEN-OX) e ácido cítrico com / Periodontal regenerative treatment of two or three walls-defects intra bony made in animals and humans, using anorganic bovine bone, resorbable membrane of bovine cortical bone and citric acid with tetracycline

Ana Lúcia Raphaelli Nahás 13 February 2004 (has links)
Este estudo teve como objetivo avaliar a biocompatibilidade em coelhos e a regeneração periodontal em defeitos intra-ósseos em humanos, utilizando o osso inorgânico bovino (Gen-Ox). Cinco grupos de coelhos, contendo 5 em cada um deles, foram sacrificados nos períodos de 30, 60, 90, 180 e 270 dias, após a colocação do enxerto ósseo. No estudo em humanos, a amostra constou de 10 indivíduos com idade entre 25 e 60 anos, apresentando um par de defeitos intra-ósseos, localizados no mesmo arco dentário em dentes do mesmo tipo (pré-molares ou molares) e com perda de inserção (PI) 5mm. Em cada indivíduo, o lado teste foi tratado na superfície radicular com aplicação de ácido cítrico com tetraciclina, preenchido o defeito com osso inorgânico bovino (Gen-Ox), e adaptada a membrana reabsorvível de osso cortical bovino (Gen-Derm), enquanto o lado controle foi tratado na superfície radicular com aplicação de ácido cítrico com tetraciclina e adaptada a membrana reabsorvível (Gen-Derm). Houve uma redução significante no nível de inserção nos dois grupos, quando avaliados na comparação entre os períodos pré-operatórios e aos seis meses de pós-operatório, tendo o grupo teste mostrado uma melhora significante quando comparado ao grupo controle (teste t pareado, p=0,038). Foram feitos controles radiográficos padronizados de ambos os grupos para a obtenção das medidas individuais, com posterior análise estatística das variações das medidas. MEDIDA 1, da Junção Cemento Esmalte até o final do ápice da raiz (J.C.E.-A). MEDIDA 2, da J.C.E.- RT (até o início da radiotransparência). MEDIDA 3, da J.C.E.-D (até o final do defeito). As variações ocorridas no período entre a radiografia inicial e 6 meses alcançaram significância estatística somente para a medida 1 (p=0,03), radiografia inicial e 12 meses para as medidas 1 (p=0,043) e 3 (p=0,001) pelo teste de Tukey. Conclui-se que na avaliação histológica em coelhos, nos períodos de 3 a 9 meses, ocorreu a remodelação óssea e a estabilização do processo de reparo. Em humanos, houve uma significância estatística nos períodos de 1 a 6 meses (grupo teste), tanto na sondagem quanto na avaliação radiográfica, e no período de 6 a 12 meses, não houve diferença significante entre os grupos. / This study aimed at evaluating the biocompatibility in rabbits and the periodontal regeneration of intra-bony defects in humans, utilizing a bovine inorganic bone (Gen-Ox). Five groups of rabbits, containing 5 in each group, were sacrificed in the periods of 30, 60, 90, 180 and 270 days, following the bone graft. In the study in humans, the sample was comprised of 10 individuals in the age range 25 - 60 yrs, presenting a pair of intra-bony defects, located in the same dental arch, in teeth of the same type (pre-molars or molars) and with an insertion loss (IL) 5mm. In each individual, the test side was treated on the root surface, with the application of citric acid with tetracycline and the bone defect filled with bovine inorganic bone (Gen-Ox), being the resorbable membrane of bovine cortical bone (Gen-Derm) adapted, while the control side was treated on the root surface, with the application of citric acid with tetracycline, being the resorbable membrane (Gen-Derm) adapted. There was a significant reduction in the insertion level in the two groups, when evaluated between the pre-surgical periods and at six months, postoperatively, the test group showing a significant improvement as compared to the control (paired t test, p=0.038). Standardized radiographic controls were made of both groups, so as to obtain individual measurements, followed by statistical analysis of the measurement variations. MEASUREMENT 1, from the cementoenamel junction up to the end of the root apex (J.C.E.-A). MEASUREMENT 2, from the J.C.E.-RT (up to the beginning of radio-transparency). MEASUREMENT 3, from the J.C.E.-D (up to the end of defect). The variations occurred in the period between the initial radiography and 6 months, had statistical significance only for measurement 1 (p=0.03), initial radiography and 12 months for measurements 1 (p=0.043) and 3 (p=0.001), by Tukey´s test. It was concluded that in the histological evaluation of rabbits, in the periods of 3 to 9 months, there was a bone remodeling and stabilization of the repair process. In humans, there was a statistical significance in the periods of 1 to 6 months (test group), both in probing and radiographic evaluation, and in the period 6 to 12 months, no significant difference was seen between the groups.
90

Efeito sobre o reparo ósseo de campo magnético sepultado em crânio de ratos após reconstrução com osso autógeno, hidroxiapatita sintética e cartilagem alógena

Abreu, Maíra Cavallet de January 2012 (has links)
A compreensão dos fenômenos de reparo ósseo representa parte fundamental da odontologia e da cirurgia bucomaxilofacial. Objetivo: O presente trabalho tem como objetivo avaliar a influência da estimulação de campo magnético sepultado sobre o reparo ósseo em calvária de ratos após reconstrução com enxerto ósseo autógeno, implante de hidroxiapatita granulada sintética ou enxerto alógeno de cartilagem, comparados entre si e aos controles sem estimulação magnética. Materiais e métodos: foram utilizados 95 ratos Wistar machos, divididos em grupos constituidos por 5 animais. Foram realizados defeitos ósseos críticos na calvária dos animais, sendo os mesmos imediatamente reconstruídos, isoladamente com, enxerto ósseo autógeno, hidroxiapatita granulada sintética e enxerto alógeno de cartilagem, sob influência ou não de campos magnéticos sepultados. Foram realizadas avaliações aos 15, 30 e 60 dias pós-operatórios. Apenas um grupo não sofreu intervenção cirúrgica (Naive), para fornecer os dados para obtenção da atividade fisiológica das enzimas fosfatase alcalina e fosfatase ácida. Em todos os tempos experimentais foi realizada a quantificação da neoformação óssea por meio da histomorfometria. A avaliação da intensidade de expressão da proteína osteopontina, foi obtida somente aos 60 dias Resultados: a avaliação histomorfométrica evidenciou interação significativa entre grupos e tempos com p=0,008. Aos 60 dias, nos animais que receberam reconstrução com osso autógeno o grupo sob influência do campo magnético apresentou percentual de preenchimento ósseo superior ao grupo sem influência do estímulo magnético. A mensuração da atividade das enzimas fosfatase alcalina e fosfatase ácida evidenciou interação significativa entre grupos e tempos com p=0,02 e p=0,005 respectivamente. Aos 60 dias, todos os grupos apresentaram atividade de ambas enzimas significativamente inferior ao grupo Naive. A análise imunoistoquímica realizada não evidenciou diferença significativa na expressão da enzima osteopontina com a metodologia empregada. Conclusão: o presente trabalho contribuiu para o entendimento da influência do campo magnético sepultado sobre o reparo ósseo em crânio de rato. A partir dos resultados encontrados, novas metodologias podem ser propostas para complementar os resultados obtidos e fortalecer a presente linha de pesquisa. / Objective: the comprehension of the phenomenon of bone repair represents a fundamental part of dentistry and of oral and maxillofacial surgery. The present work has as its objective, to evaluate the influence of a stimulated magnetic field implanted on the calvarial bone of rats after its reconstruction with autogeneous bone graft, synthetic hydroxyapatite crystals or with the insertion of allogeneic cartilage, in comparison to no magnetic stimulation. Materials e methods: 95 Wistar male rats were used, divided into groups with 5 animals in each. The autogeneous bone graft, the synthetic hydroxyapatite crystals and the insertion of allogeneic cartilage were each used separately in the performed interventions of reconstruction with or without the influence of implanted magnetic fields. Evaluations were performed in 15, 30 and 60 days after surgery. Only one group did not suffer surgical intervention (Naïve); this group provided data for the physiological activity of the alkaline and acid phosphatase enzymes. Also, quantification of bone neoformation was obtained through histomorphometry in all experimental time periods, and evaluation of the osteopontin protein expression of intensity in 60 days. Results: the histomorphometry 60-day evaluation, showed evidence of a significant interaction between the groups and the time of p=0,008 on the animals that received reconstruction with autogeneous bone. The group that was influenced by the magnetic field presented a percent of bone reconstruction superior to that of the group which did not receive magnetic stimulation. In 60 days, activity mensuration of the alkaline and acid phosphatase enzymes, showed evidence of significant interaction between the groups and the times of p=0,02 and p=0,005, respectively. In all groups, activity of both enzymes was present and significantly inferior to the Naive group. The immunohistochemistry analysis performed did not show evidence of any significant difference in the oseopontin enzyme expression with the applied methodology. Conclusion: this work contributed to the understanding of the influence that an implanted magnetic field has on bone reconstruction. From the results found, new methodologies can be proposed as a complementary to obtained results and can strengthen the present line of research.

Page generated in 0.1109 seconds