Spelling suggestions: "subject:"materiais incompatíveis"" "subject:"materiais biocombustíveis""
71 |
Síntese, caracterização e avaliação da citocompatibilidade in vitro de poliuretano como biomaterial na engenharia tecidualViezzer, Christian January 2009 (has links)
Made available in DSpace on 2013-08-07T18:54:53Z (GMT). No. of bitstreams: 1
000413812-Texto+Completo-0.pdf: 2939251 bytes, checksum: 2d3f8accd8d398c256cab783e281fed7 (MD5)
Previous issue date: 2009 / The use of synthetic polymers to manufature biomaterials has attracting attention of many researchers, aiming to develop of implants that can improve tissue regeneration by contact with specific cellular types in contact with biodegradable synthetic polymers. Polyurethanes (PU) are considered one of the most versatile biomaterials at present, due to it good mechanical properties and its tissue compatibility. In the present work the synthesis of poliurethanes to by use as biomaterials utilizing hexamethylene diisocyanate (HDI) and poly (ε-caprolactone) (PCL) was evaluated. The synthesized polymer was characterized by Gel Permeation Chromatography (GPC), Fourier Transform Infrared Spectroscopy (FTIR) and Nuclear Magnetic Resonance (1H-NMR). In vitro cytotoxicity was also evaluated by tetrazolium salt reduction assay (MTT) and in vitro cellular adhesion with mouse fibroblast cells. The results obtained in confirmed the cytocompatibility of the PU polymer and that it did interfer with cell adhesion and proliferation. / A utilização de polímeros sintéticos na fabricação de biomateriais tem despertado a atenção de muitos pesquisadores, visando a criação de implantes que possam auxiliar na regeneração tecidual, através do contato de tipos celulares específicos com os polímeros sintéticos biodegradáveis. Os poliuretanos (PU) são considerados como um dos biomateriais mais versáteis atualmente utilizados devido suas ótimas propriedades mecânicas e sua compatibilidade tecidual. No presente trabalho, foi estudada a síntese de poliuretanos para uso como biomateriais utilizando hexametileno diisocianato e poli(e-caprolactona) (PCL). O polímero sintetizado foi caracterizado por Cromatografia de Permeação em Gel (GPC), Espectroscopia de Infravermelho por Transformada de Fourier (FTIR) e Ressonância Magnética Nuclear (1H-RMN). A sua citotoxicidade foi avaliada utilizando o ensaio de redução do sal de tetrazólio (MTT), também foi avaliado a adesão celular in vitro com fibroblastos de camundongos. Os resultados obtidos no presente estudo confirmaram a citocompatibilidade do polímero de PU que não interferiu no processo de adesão e proliferação celular.
|
72 |
Desenvolvimento e caracterização de nanotubos de TiO2 em implantes de titânioBessauer, Luciano Herbstrith January 2011 (has links)
Made available in DSpace on 2013-08-07T18:54:54Z (GMT). No. of bitstreams: 1
000434834-Texto+Completo-0.pdf: 2467680 bytes, checksum: d94eca86dabe6ec28377349c07e8a880 (MD5)
Previous issue date: 2011 / The passive behavior of the titanium oxide layer formed is an important characteristic for the biomedical application. The interactions with the biological environment after the implantation of a prosthesis are directly linked, among others factors, with the physicist-chemical properties of the surface of the implanted material. Titanium surfaces that are chemical or electrochemical treated tend to develop specific layers with chemical composition and porosity that promote osseointegration. The goal of this work is to study anodization process, to develop the nanotubes growth in titanium substrate. Electrolytic solutions of 1M H3PO4 and 0. 2 % HF were used varying the applied voltage and the distance among the electrodes. After the process anodic the specimens were treated thermally in the temperatures of 500, 600, 700, 800 and 900°C. The formed films and treaties thermally were analyzed by scanning electronic microscopy (SEM), energy dispersive spectroscopy (EDS) and X-rays diffraction (DRX). The results nominated to the formation of nanotubes in the anodic treated titanium oxides films in every extension of the surface, in addition to uniformity of the oxide layer and regularity of the diameter of nanotubes the 0,171mm. The analyses of the chemical composition indicated the presence of match, derived of the terms of the experiment. The structure crystallographic verified was hexagonal, which corresponds to the titanium structure. / O comportamento passivante da camada formada de óxido de titânio é uma característica relevante para a aplicação biomédica. As interações com o meio biológico após a implantação de uma prótese estão diretamente ligadas, entre outros fatores, com as propriedades físico-químicas da superfície do material implantado. As superfícies de titânio que são tratadas química ou eletroquimicamente tendem a desenvolver camadas específicas com composição química e porosidade que promovem a osseointegração. O objetivo deste trabalho é estudar o processo de anodização para desenvolver o crescimento de nanotubos de TiO2 em substrato de titânio comercialmente puro. Foram utilizadas soluções eletrolíticas de 1M H3PO4 e 0,2 % de HF variando a tensão aplicada e alterando o distanciamento entre os eletrodos. Após o processo anódico as espécimes foram tratadas termicamente nas temperaturas de 500, 600, 700, 800 e 900°C. Os film es formados e tratados termicamente foram analisados por microscopia eletrônica de varredura (MEV), espectroscopia por energia dispersiva (EDS) e difratometria de raios X (DRX). Os resultados indicaram a formação de nanotubos nos filmes de óxidos de titânio tratados anodicamente em toda extensão da superfície, além de boa uniformidade da camada de óxido e regularidade do diâmetro dos nanotubos de 171nm. As análises da composição química indicaram a presença de fósforo, oriundos das condições do experimento. A estrutura cristalográfica verificada foi hexagonal, a qual corresponde à estrutura do titânio.
|
73 |
Confecção de estruturas tubulares permeáveis de PLGASchardosim, Mariane Giacomini January 2012 (has links)
Made available in DSpace on 2013-08-07T18:54:45Z (GMT). No. of bitstreams: 1
000443125-Texto+Completo-0.pdf: 1527521 bytes, checksum: 2c9a9ef7ac02480e7ed3b2734a8acc04 (MD5)
Previous issue date: null / Peripheral nerve injury accident is a common type of lesion that can cause loss of mobility and decrease the quality of life. Despite advances in the biomedical area, there are few cases where there is complete functional recovery of a damaged nerve. The application of biodegradable polymers such as poly(lactide-co-glycolide) (PLGA), shows a viable alternative of treatment in peripheral nerves injuries for presenting mechanical strength, biocompatibility and controlled degradation, being also an excellent material for drug delivery. A PLGA scaffold should be porous with pore sizes on the order of micro-and nanometer, which offers the possibility to insert growth factors, promoting a constant release of these biological structures. The aim of this research is to produce porous scaffolds of PLGA. This was achieved by dissolving the polymer in chloroform, adding a porogenic compound. A titanium rod with 2mm in diameter was deeped in the suspension obtained and dried in a hood, obtaining a layer of PLGA / porogen agent on the surface of the rod. In sequence, the rod was immersed in a solution of PLGA with chloroform. After dried for 2 hours in a hood, the titanium rods were submerged in deionized water for 48 hours, during which the water was changed every 8 hours in order to remove the porogenic agent. After this process, the tubular structures formed were easily removed from the rods. Finally, the prepared tubes were divided into groups and treated with different concentrations of sodium hydroxide, to create pores in the order of nanometers, and subsequently vacuum dried for 48 hours. The structures obtained were characterized by XRD, FTIR, SEM and the in vitro degradation was monitored by GPC. / Danos a nervos periféricos são formas comuns de lesões que podem causar perda de mobilidade e diminuir a qualidade de vida. Apesar dos avanços no campo biomédico, existem poucos casos em que há recuperação funcional completa de um nervo danificado. A aplicação de polímeros biodegradáveis tais como PLGA, apresenta uma alternativa viável no tratamento de lesões de nervos periféricos por possuir resistência mecânica, biocompatibilidade e degradação controlada. Uma matriz de PLGA deve apresentar poros na ordem de micrômetros e nanômetros, oferecendo a possibilidade de inclusão de fatores de crescimento e possivelmente promovendo uma libertação constante destas estruturas biológicas. O objetivo desta pesquisa é produzir matrizes porosas de PLGA. Isto foi realizado através da dissolução do polímero em clorofórmio, seguida da adição de um composto porogênico. Uma haste de titânio com 2mm de diâmetro foi imersa na suspensão obtida e quando retirada, foi seca em capela, obtendo uma camada de PLGA/agente porogênico na superfície da haste. Na sequência, a haste foi imersa em uma solução de PLGA com clorofórmio. Após seca durante 2h em capela, as hastes de titânio foram submersas em água deionizada durante 48h, durante as quais, a água foi trocada a cada 8h, para remoção do agente porogênico. Após este processo, as estruturas tubulares formadas são facilmente removidas das hastes. Finalmente, os tubos confeccionados foram divididos em grupos, e tratados com diferentes concentrações de hidróxido de sódio, para criação de poros na ordem de nanômetros, sendo, subsequentemente, secos em forno a vácuo durante 48h. As estruturas obtidas foram caracterizadas por XRD, FTIR, MEV e a degradação in vitro foi acompanhada por GPC.
|
74 |
Estudo clínico e histopatologico da aplicação do polimetilmetacrilato (PMMA) em ratosJesus, Luciano Henrique de January 2011 (has links)
Objetivo: O objetivo deste estudo foi avaliar clínica e hitologicamente a reação do material de preenchimento em dois sítios diferentes. Método: Vinte e duas femêas de ratos Wistar (Rattus novergicus) foram submetidas a aplicação de PMMA testando duas técnicas: subcutânea e transmuscular. Passados 3 meses do ato cirúrgico os ratos foram eutanasiados e as áreas injetadas foram excisadas, submetidas a técnica de inclusão em parafina e coloração por hematoxilina e eosina. As lâminas foram analisadas observando-se a resposta local à injeção do corpo estranho quanto ao grau de inflamação. Resultados: Foi encontrada diferença significativamente estatística entre os sítios muscular e subdérmico quanto a formação de granuloma (p<0,05), sendo que o grupo subdérmico obteve melhores resultados. Conclusão: A aplicação de materiais de preenchimento, que provoca maior trauma e sangramento nos tecidos, é a casusa de reações adversas. / Objective: The objective of this study was to evaluate clinical and hitopathology the reaction of the fill material at two different sites. Method: Twenty-two female Wistar rats (Rattus norvegicus) submitted the application of PMMA testing two techniques: subcutaneous and trans. After 3 months of surgery, the rats were euthanized and the injected areas were excised, subjected to paraffin embedding technique and stained with hematoxylin and eosin. The slides were analyzed by observing the local response to injection of foreign body in the degree of inflammation. Results: We found statistically significant differences between sites and subdermal muscle as granuloma formation (p <0.05), and the subdermal group achieved better results. Conclusion: The application of filling materials, which causes more injury and bleeding in the tissues, is Casusa of adverse reactions.
|
75 |
Avaliação histomorfométrica comparativa do processo de reparo de defeitos ósseos perenes em calvária de ratos tratados com -fosfato tricálcio, hidroxiapatita sintética, hidroxiapatita sintética + -fosfato tricálcio e osso autógeno / Histomorphometric comparative evaluation of the repair of perennial bone defects in rats skulls treated with -tricalcium phosphate, synthetic hydroxyapatite, synthetic hydroxyapatite + -tricalcium phosphate and autogenous graftAngélica Cristina de Oliveira Martins 26 April 2010 (has links)
Os objetivos do trabalho foram caracterizar as biocerâmicas a base de hidroxiapatita (HA), -fosfato tricálcio (TCP) e o compósito HA/TCP na proporção 60:40 pela análise microestrutural e por Espectrometria de Energia Dispersiva de Raios-X (EDS) ao microscópio eletrônico de varredura, e comparar histomorfometricamente o processo de reparo ósseo de defeitos cranianos perenes tratados com essas três diferentes cerâmicas e o enxerto autógeno nos períodos de 0, 30, 90 e 180 dias pós-operatório. Microestruturalmente, a HA apresentou superfície irregular com concavidades, fendas e grande quantidade de microporos; o TCP exibiu superfície irregular e baixa resistência mecânica; a HA/TCP apresentou superfície lisa com raras concavidades e ausência de porosidades. As cerâmicas estavam constituídas pelos elementos O, P e Ca, sendo que a relação Ca/P seguiu a ordem: HA/TCP > HA > TCP. Morfometricamente, o volume inicial enxertado foi aproximadamente de 60 mm3 para todos os tratamentos. Entre 30 e 180 dias, o volume total da região do enxerto (Vtre) e do material enxertado (VM) manteve-se constante nos defeitos tratados com osso autógeno (Vtre = 53,61 mm³, VM =20,11 mm³), HA (Vtre = 60,13mm³, VM = 32,72 mm³), HA/TCP (Vtre = 57,60mm³, VM = 31,61 mm³), TCP (Vtre = 38,27mm3, VM = 10,07 mm³). Aos 30 dias, o volume de tecido ósseo no grupo autógeno foi de 22,06 mm³, ocupando quase a totalidade dos espaços entre as partículas, enquanto que, nos grupos HA e HA/TCP foi de apenas 7,62 mm³, sendo parte dos espaços (19,10 mm3), constituído por tecido conjuntivo fibroso. Entre 30 e 180 dias, o volume de tecido ósseo não apresentou diferenças estatísticas significantes (p>0,05). O número absoluto de osteoblastos e osteócitos no grupo autógeno foi, respectivamente, de 118,57 x102 e 178,57 x102 células, aos 30 dias, diminuindo 40,16% e 29,09% aos 90 dias, decorrente do processo de remodelação óssea. Nos grupos HA e HA/TCP, o número absoluto de osteoblastos e osteócitos foram similares e permaneceram constantes dos 30 aos 180 dias, com uma média de 39,13 x102 e 132,20 x102 células, respectivamente. Com relação ao grupo TCP, o volume de tecido ósseo foi de 4,16mm3 aos 30 dias e aumentou 70,27% aos 90 dias, passando a ocupar 13,93 mm³ do Vtre. Concomitantemente, o número absoluto de osteoblastos e osteócitos passaram, respectivamente, de 5,64 x102 e 37,01 x102 células, aos 30 dias, para 67,46 x102 e 166,13 x102 células, aos 90 dias. Baseados nos resultados aqui obtidos, concluímos que, no modelo experimental de defeitos cranianos em ratos, o enxerto autógeno é ainda, o padrão ouro para reconstrução óssea, enquanto que, dentre as cerâmicas analisadas, o TCP é o melhor biomaterial ósseo-substituto. / The aim of the work was to characterize the ceramics: hydroxyapatite (HA), -tricalcium phosphate (TCP) and the composite HA/TCP (60:40) through scaning electron microscope - energy dispersive system (SEM-EDS) analysis and to compare histomorphometrically the repair of perennial skull defects treated with these three different ceramics and autogenous graft at 0, 30, 90 and 180 days post-operatively. Microstructurally, HA showed irregular surface with concavities, cracks and several pores. TCP also presented irregular surface and low mechanical strength. HA/TCP showed smooth surface with rare concavities and pores. The ceramics were constituted by the elements O, P and Ca, and the relation Ca/P follow the order: HA/TCP > HA > TCP. Morphometrically, the initial graft volume was approximately 60 mm3 for all treatments. Between 30 and 180 days, the total volume of the grafted area (Vtga) and of the implanted material (Vim) were constant in the following groups: autogenous (Vtga = 53,61 mm³; Vim = 20,11 mm3), HA (Vtga = 60,13mm³; Vim = 32,72 mm3), HA/TCP (Vtga = 57,60mm³; Vim = 31,61 mm3) and TCP (Vtga = 38,27mm³; Vim = 10,07 mm3). At 30 days, the bone tissue volume was of 22,06 mm3 in the autogenous group, occupying totally the space among the particles, while in the HA and HA/TCP groups was only 7,62 mm3. At 30 and 180 days, the bone tissue volume did not show statistical differences (p>0.05). The total number of osteoblasts and osteocytes in the autogenous group was respectively, 118, 57 x 102 and 178,57 x 102 cells, at 30 days, reducing 40,16% e 29,09%, at 90 days, due to bone remodeling. In the HA and HA/TCP groups, a similar and stable number of osteoblasts and osteocytes were observed during all periods, with mean of 39,13 x 102 and 132,20 x 102 cells, respectively. In the TCP group, the bony tissue volume was of 4,16 mm3, at 30 days, increasing 70,27% at 90 days. Concomitantly, the total number of osteoblasts and osteocytes was respectively, 5,64 x 102 and 37,01 x 102 cells, at 30 days, achieving 67,46 x 102 and 166,13 x 102 cells, at 90 days. Based in the results obtained here, we concluded that in the rat skull defect model the autogenous bone is yet the good standard graft material for bone reconstruction and that among the tested ceramics, the TCP is the best bone graft substitute.
|
76 |
Resposta in vitro de células pré-osteoblásticas em cerâmica de hidroxiapatitaLuara Aline Pires 08 April 2015 (has links)
Com a evolução do Biomateriais houve melhorias nas opções de tratamentos e atualmente são utilizados em substituição de partes do corpo que foram perdidas e promovem a recuperação de funções biológicas. Dentre eles existem as chamadas Biocerâmicas, que incluem alumina, zircônia e derivadas de fosfato de cálcio. A hidroxiapatita possui composição e estrutura minerais semelhantes à fase mineral óssea e apresenta como propriedades a biocompatibilidade, osteocondutividade e bioatividade. O trabalho avaliou a viabilidade celular em cerâmica de hidroxiapatita experimental de origem bovina em comparação com dois tipos de zircônia comerciais e liga de titânio comercialmente puro, para que futuramente possa ser utilizada como material base para implantes dentários. A avaliação in vitro foi realizada por meio de testes nos quais células pré-osteoblásticas cultivadas de linhagem murina MC3T3-E1 foram colocadas em contato indireto e direto com estes materiais. Para viabilidade celular (n=8) foram feitos testes de ensaio MTT e Cristal Violeta em duplicata e após 24, 48 e 72 horas os níveis de absorbâncias foram analisados por meio de espectrofotometria no leitor de Elisa. Para as analises por microscopia eletrônica de varredura (n=6) as células foram plaqueadas diretamente sobre as superfícies dos discos, fixadas em vapor de tetróxido de ósmio 2% após 24 e 48 horas, seguido da metalização após 48 horas da fixação das células para análise em Microscópio Eletrônico de Varredura. Os resultados para viabilidade indireta foram submetidos ao teste paramétrico ANOVA, seguido de teste de Tukey (p<0,05). Tanto no teste de MTT quanto no Cristal Violeta, de acordo com o grupo controle positivo, todos os grupos apresentaram resultados satisfatórios. A cerâmica de hidroxiapatita não apresentou diferença estatística significante, demonstrando não ser um material citotóxico. Pelas imagens geradas no MEV do teste de viabilidade direta, verificou-se que houve adesão e proliferação das células nos dois períodos sobre as superfícies dos materiais. Portanto, pode-se afirmar que a cerâmica de hidroxiapatita apresentou-se como um material biocompatível. / With the evolution biomaterials there were improvements in treatment options, and are currently used in replacement body parts that were lost and promote the recovery of biological functions. Among them are the bioceramic which include alumina, zirconia and calcium phosphate derivative. Hydroxyapatite has mineral composition and structure similar to bone mineral phase and can be used as a biomaterial having biocompatibility, osteoconductivity and bioactivity. The study evaluated the cell viability in experimental hydroxyapatite ceramic bovine compared the two types of commercial zirconia and titanium alloy commercially pure, so that in future it can be used as base material for dental implants. In vitro evaluation was carried by means of tests in which the pre-osteoblastic cells MC3T3-E1 murine lineage cultured were placed in indirect and direct contact with these materials. For cell viability (n=8) were carried MTT assay and Crystal Violet tests in duplicate and after 24, 48 and 72 hours the absorbance levels were analyzed by spectrophotometry Elisa reader. For analysis by Scanning Electron Microscope variable pressure (n = 6) cells were plated directly on the discs surfaces, fixed in osmium tetroxide steam 2% after 24 and 48 hours, followed by metallization after 48 of cells fixation. The results for the cell viability were submitted to parametric test ANOVA, followed by Tukey test (p<0.05). Both in the MTT assay as Crystal Violet all groups exhibited satisfactory results absent cytotoxicity. By means of the SEM images produced, it was found that there was adhesion and proliferation of cells on the materials surfaces in the two periods. Therefore, it can be stated that the hydroxyapatite ceramic was presented as a biocompatible material.
|
77 |
Avaliação da resistência a tração de diferentes enxertos em calvária de ratos / Evaluation of the tensile strength of different grafts in rat calvariaJefferson Tomio Sanada 15 December 2010 (has links)
A perda do osso alveolar como resultado de doença periodontal ou secundariamente à cirurgia são fontes de inúmeras complicações para os cirurgiões dentistas, e a solução para tal problema se baseiam em procedimentos regenerativos, que é realizada através de enxertos ósseos que estabelecem um arcabouço para a reparação tecidual, aumentando os tecidos ósseos nos defeitos resultantes de trauma ou cirurgias, preenchendo os alvéolos após extração para preservar a altura e espessura do rebordo alveolar e aumentando e/ou reconstruindo o rebordo alveolar. Este projeto tem como objetivo determinar a resistência à tração do osso neoformado com a utilização de diferentes biomateriais. Foram utilizados 60 animais divididos em 3 grupos. O grupo 1A (n=10): GenO; Grupo 1B (n=10): GenMix; Grupo1C (n=10): Bio-Oss; Grupo 2a (n=10): PerioGlas; Grupo 2b (n=10): Polímero de mamona e Grupo 3 (n=10): coágulo. Após 3 meses de nascimento os animais foram submetidos a anestesia intraperitonial e confecção de defeito não critico (3mm de diâmetro) na calvária dos animais, que foram preenchidos com os biomateriais correspondentes a cada grupo. Após 6 meses da cirurgia foi realizada a morte dos animais, os espécimes foram coletados e submetidos ao teste em uma máquina de teste universal. Observa-se que o grupo que obteve maior média de resistência à tração foi o grupo de polímero de mamona (10,932±4,529MPa). Consequentemente, obteve-se uma comparação descrescente na seguinte ordem: Coágulo (9,563±3,74MPa), Bio-Oss (8,706±4,087MPa), GenMix (8,587±3,602MPa), GenOx (7,709±2,416MPa), PerioGlas (7,185±6,837MPa), não notando-se diferença estatisticamente significante entre os grupos. Nas microscopias eletrônicas de varredura na maioria dos grupos observou-se presença de fibras colágenas ao redor do tecido ósseo neoformado e dos remanescentes de enxerto. Conclui-se que o material foi indiferente para o resultado final da resistência à tração, demonstrando uma boa qualidade dos materiais utilizados, tanto quando comparamos os produtos quanto a sua origem (xenogênica, polimérica ou coágulo), ou a sua procedência de fabricação (nacional ou importado). / The loss of alveolar bone as a result of periodontal disease or secondary to surgery are numerous sources of complications for the dentists, and the solution to this problem are based on regenerative procedures, which is conducted through bone grafts that provide a scaffold for tissue repair by increasing the bone tissues in the defects resulting from trauma or surgery, filling the alveoli after extraction to preserve the height and thickness and increasing the alveolar ridge and/or reconstructing the alveolar ridge. This project aims to determine the tensile strength of newly formed bone with the use of different biomaterials. We used 60 animals divided into three groups. Group 1A (n = 10): GenOx; Group 1B (n = 10): GenMix; Group 1C (n = 10): Bio-Oss; Groups 2a (n = 10): PerioGlas; Group 2b (n = 10): castor bean polymer; Group 3 (n = 10): clot. After 3 months of birth the animals were anesthetized intraperitoneally and making non critical defect (3mm diameter) in the calvaria of the animals, which were filled with biomaterials for each group. After 6 months of surgery was performed the animals\' death, the specimens were collected and tested in a universal testing machine. It is observed that the group had a higher average tensile strength was the castor oil polymer group (10.932 ± 4.529 MPa). Consequently, we obtained a comparison descended in the following order: Clot (9.563 ± 3.74 MPa), Bio-Oss (8.706 ± 4.087 MPa), GenMix (8.587 ± 3.602 MPa), GenOx (7.709 ± 2.416 MPa), PerioGlas (7.185 ± 6.837 MPa), not noticing a significant difference between the groups. In scanning electron microscopies in most groups there was presence of collagen fibers around the newly formed bone and remaining graft. It is concluded that the material was irrelevant to the final result of the tensile strength, showing a good quality of materials used, both when comparing products as their source (xenogenic, polymeric or clot), or its origin of manufacture (national or imported).
|
78 |
Avaliação da resistência e módulo de elasticidade de osso mineralizado e desmineralizado pelos testes de microtração / Evaluation of the resistance and modulus of elasticity of bone mineralized and desmineralized for the tests of microtensileJefferson Tomio Sanada 28 March 2007 (has links)
A perda do osso alveolar como resultado de doença periodontal ou secundariamente à cirurgia são fontes de inúmeras complicações para os cirurgiões dentistas, e a solução para tal problema se baseiam em procedimentos regenerativos. A regeneração é feita através de enxertos ósseos que estabelecem um arcabouço para a reparação tecidual, aumentando os tecidos ósseos nos defeitos resultantes de trauma ou cirurgias, preenchendo os alvéolos após extração para preservar a altura e espessura do rebordo alveolar e aumentando e/ou reconstruindo o rebordo alveolar. Estes procedimentos são realizados através da utilização de enxertos autógenos, alógenos, aloplásticos ou xenogênicos, tendo cada um suas características e indicações. Com o desenvolvimento dos implantes osseointegrados, viu-se a necessidade de manter uma boa quantidade e qualidade óssea. Este projeto tem como objetivo avaliar a resistência a tração e módulo de elasticidade do osso mineralizado e desmineralizado de calvária de ratos, a fim de determinar padrões iniciais (máximos e mínimos) para comparações com possíveis biomateriais de preenchimento de osteoindução e osteocondução. Foram utilizados 24 animais divididos em 2 grupos. O grupo 1 (n=12): módulo de elasticidade sendo que utilizaremos as duas parietais do animal, possibilitando 24 espécimes, subdividido em mineralizado (n=12) e desmineralizado (n=12). O grupo 2 (n=12): microtração, sendo que 12 hemicalvária foram utilizado para o sub-grupo desmineralizado e as outras 12 hemicalvária para o sub-grupo mineralizado. Após a morte dos animais, os espécimes serão coletados e tratados de acordo com o subgrupo (mineralizado e desmineralizado). Os testes foram realizados numa máquina de teste universal (Vitrodyme, V1000). As médias de resistência a tração do mineralizado foi 129,814 ± 34,921 MPa e o desmineralizado foi 18,547 ± 3,682 MPa. Para o módulo de elasticidade obtivemos os valores de 1377,792 ± 208,331 MPa para o grupo mineralizado e 49,669 ± 11,204 MPa para o grupo desmineralizado, ao compararmos o módulo de elasticidade e resistência a tração entre os subgrupo desmineralizado e mineralizado observa-se uma diferença estatisticamente significante para o grupo mineralizado (p<0,001). Conclui-se que o teste de microtração pode ser utilizado para avaliar as propriedades mecânicas nesse modelo experimental biológico. / The loss of the alveolar bone as resulted of periodontal illness or second to the surgery is sources of innumerable complications for the surgeons dentists, and the solution for such problem if it bases on regenerative procedures. Regeneration is made through bone grafts that establish one scaffold for the tecidual repairing, increasing bone fabrics in the resultant defects of trauma or surgeries, filling the alveolous after extraction to preserve the height and thickness of the alveolar rigde and being increased and/or reconstructing the alveolar rigde. These procedures are carried through the use of autogenous, alografts, aloplastic or xenogenics grafts, having each one its characteristics and indications. With the development of the osseointegrated implants, it was seen necessity to keep a good amount and bone quality. This project has as objective to evaluate the resistance the traction and modulus of elasticity of the mineralized bone and desmineralized.of calvarium of rats, similar to determine initial standards (maximum and minimum) for comparisons with possible biomateriais of fulfilling of osteoinduction and osteoconduction. 24 animals divided in 2 groups had been used. Group 1 (n=12): modulus of elasticity being that we will use the two parietals of the animal, having made possible 24 specimens, subdivided in mineralized (n=12) and desmineralized (n=12). Group 2 (n=12): microtraction, being that 12 hemi-calvarium had been used for 12 the desmineralized sub-group and the others hemi-calvarium for the mineralized sub-group. After the death of the animals, the specimens will be collected and treated in accordance with the sub-group (mineralized and desmineralized). The tests had been carried through in a machine of universal test (Vitrodyme, V1000). The resistance averages the traction of the mineralized one was mineralized 129,814 ± 34.921 MPa and the desmineralized one was 18,547 ± 3,682 MPa. For the modulus of elasticity we got values of 1377,792 ± 208.331 MPa for the mineralized group and 49,669 ± 11,204 MPa for the desmineralized group, when comparing the resistance and modulus of elasticity the traction between the desmineralized and mineralized sub-group observes a estatistical significant difference for the mineralized group (p<0,001). Concluded that the microtraction test can be used to evaluate the mechanical properties in this biological experimental model.
|
79 |
Análise da resposta inflamatória à implantação de membranas de PLGA+lactamas e PLGA+nanopartículas de prata no tecido subcutâneo de ratosRibeiro, Débora Amgarten January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:09:53Z (GMT). No. of bitstreams: 1
341274.pdf: 2062367 bytes, checksum: 9e2c31ae12105178caf4239749a1d515 (MD5)
Previous issue date: 2016 / As implicações biológicas da incorporação de agentes antibiofilmes às membranas utilizadas nas técnicas reconstrutivas de tecido ósseo não estão completamente esclarecidas. O objetivo deste estudo foi analisar a resposta inflamatória à implantação subcutânea de membranas de PLGA (ácido polilático co-glicólico) associadas a duas categorias de agentes antibiofilme: quatro tipos de lactamas e dois de nanopartículas de prata. Foram implantados, ao todo, 08 tipos de membranas (controles e testes) em 45 ratos Wistar adultos machos, distribuídos aleatoriamente nos períodos experimentais de 2, 7 e 30 dias. Cada animal recebeu 04 discos de membrana de 6mm de diâmetro, sendo que em todos os animais, 02 sítios obrigatoriamente receberam os discos controle (PLGA puro e colágeno) e os outros 02 sítios receberam, randomicamente, discos teste. Após cada período experimental, os animais foram anestesiados e submetidos a biópsias excisionais das áreas dos implantes e punção cardíaca (eutanásia) para a coleta de amostras de sangue e análise laboratorial - hemograma. As amostras removidas foram fixadas em formol, processadas e incluídas em parafina. A partir de cortes semi-seriados de 5 micrometros, foram confeccionadas as lâminas histológicas, coradas com HE para análise descritiva e semi-quantitativa da resposta inflamatória e biocompatilidade dos compostos testados. A membrana controle de colágeno foi a que mostrou maior reação tecidual ao longo dos 30 dias, com presença de macrófagos e células gigantes multinucleadas. As membranas testadas mostraram reação amena, muito semelhante entre si, e à membrana controle de PLGA puro. Dentro dos períodos experimentais testados, as amostras teste mostraram melhor resposta tecidual que as amostras controle.<br> / Abstract : Biological aspects of the use of membranes for tissue reconstructive procedures embedded with anti-bacterial agents are not completely elicited. The aim of this study was to analyze the inflammatory response to subcutaneous implantation of bioabsorbable poly(lactic-co-glycolic acid) - PLGA membranes embedded with two different categories of anti-bacterial agents: four types of lactams and two silver nanoparticles. Collagen and pure PLGA membranes were used as control groups. Each animal randomly received 04 membranes, 02 of them necessarily the control discs. After 02, 07 and 30 days of implantation, the animals were anesthetized for the excisional biopsy of the implant areas and for blood sample collections through cardiac puncture (euthanasia). The skin samples were histologically processed and embedded in paraffin to undergo semi-serial cuts of 5 micrometers; these slides were stained using Hematoxylin-Eosin and descriptively analyzed by light microscopy. Semi-quantitative inflammatory response analyses of the tested compounds were also made. Both tested antibiofilm agents showed a similar mild reaction with a good resolution at the end of the experimental period. Within the experimental periods tested, the test samples showed better tissue response than the control samples.
|
80 |
Avaliação histomorfométrica da biocompatibilidade do enxerto bovino misto (OrthoGen®) em tecido subcutâneo e o potencial osteogênico em defeito ósseo craniano / Histomorphometric evaluation of biocompatibility of integral bovine graft (Orthogen®) implanted in subcutaneous tissue and osteogenic potential in cranial bone defectOliveira, Tamiris Vallim Zambaldi de 20 March 2014 (has links)
O desenvolvimento atual de materiais ósseo-substitutos com potencialidade de promover o fechamento completo de um defeito ósseo crítico tem levantado questões quanto à sua atuação biológica. Uma opção de material ósseo utilizado são os enxertos ósseos de origem animal, pois possuem propriedades físicoquímicas similares ao osso humano. O osso bovino misto que preserva a estrutura colagênica e o mineral ósseo tem sido proposto e utilizado como material ósseosubstituto. O objetivo desse estudo foi avaliar a biocompatibilidade e o potencial osteogênico de um enxerto bovino ósseo subistituto, OrthoGen® (Baumer S.A.), na forma de partículas (OGp) e blocos (OGb). Para a avaliação da biocompatibilidade, 100 mg de OrthoGen® nas formas de partícula e bloco, foram implantados no subcutâneo de ratos (n=25) e o tecido reacional foi avaliado aos 7, 14, 21, 30 e 60 dias (n=5 animais/período) após a implantação. Para a análise do potencial osteogênico foram implantados 100 mg de Orthogen® nas formas de partícula e bloco em defeito critico na calvária de ratos (n=30), e a formação óssea foi mensurada aos 1, 3 e 6 meses (n=10/período) após a implantação. A análise radiográfica e histomorfométrica revelaram que no tecido subcutâneo o OGb foi melhor aceito pelo organismo quando comparado ao OGp com uma frequência menor de células gigante multinucleadas entre os períodos avaliados (OGb 0,23% vs OGp 2,19%) e consequentemente uma média de reabsorção também menor (OGb 13% vs OGp 38%). Em ambos os implantes não foi encontrado focos de infiltrado inflamatório composto por leucócitos polimorfonucleares, linfócitos e plasmócitos. Na calvária o OGb mostrou níveis de reabsorção inferiores e uma maior taxa de formação óssea quando comparado ao OGp após 6 meses (OGb 70 mm³ vs OGp 17 mm³). Baseado no modelo experimental utilizado neste estudo, concluímos que ambas as formas do Orthogen® são biocompatíveis em tecido subcutâneo, no entanto, sua forma em bloco promove uma maior formação óssea, possuindo uma capacidade osteogênica superior à forma em partícula, no modelo experimental avaliado. / The current development of bone graft materials with the potential to promote the complete closure of a critical size bone defect has raised questions as to its biological activity. An option of bone material used, are animal bone grafts since the human bone have similar physicochemical properties. Among the materials is the integral bone substitute of bovine origin, which preserves the organic and inorganic compound of the bone tissue, has been proposed and used as bone graft. The aim of this study was to evaluate the biocompatibility and osteogenic potential of a new integral bone substitute OrthogenTM (Baumer S.A.) in the form of particles (OGp) and block (OGb). For biocompatibility evaluation, 100mg OrthogenTM was implanted into dorsal subcutaneous pocket of rat (n= 25) and the reactional tissue was analyzed at 7, 14, 21, 30 and 60 days (n=5animals/period) after implantation. For osteogenic potential evaluation, 100mg OrthogenTM was implanted into critical-size defect in parietal bones of rat (n=30) and the bone formation, biomaterial reabsorption, connective tissue formation and osteoclast activity was evaluated at 1, 3 and 6 months (n=10/period) after implantation. Radiographic and histomorphometrical analysis showed that, in the subcutaneous tissue the OGb was more accepted by the host compared to OGp, with lower density of the multinucleated giant cells (OGb 0.23% vs. OGp 2.19%) and consequently a lower rate of matrix resorption (OGb 13%, vs. OGp 38%). In both implants was not found focus of inflammatory infiltrated composed by polymorphonuclear leucocytes, lymphocytes and plasmocytes. In rat calvaria the OGb showed lower rate of reabsorption and more volume of bone formation compared to OGp after 6 months (OGb 70 mm3 vs OGp 17 mm3). Based on experimental models used in this study we concluded that both forms of the OrthogenTM was biocompatible in subcutaneous tissue, however, its form of porous block promoted greater bone formation and has a higher osteogenic capacity than the particle shape, in the evaluated experimental model.
|
Page generated in 0.112 seconds