• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 3
  • 1
  • Tagged with
  • 15
  • 15
  • 7
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Caracterização físico-química, mecânica e biológica de cimento autoadesivo aditivado com nanotubos de dióxido de titânio / Physical-chemical, mechanical and biological characterization of reinforcement self-adhesive resin cement titanium dioxide nanotubes

Tonello, Carla Müller Ramos 28 November 2016 (has links)
O objetivo desse estudo foi realizar a caracterização do cimento resinoso autoadesivo RelyX U200 aditivado de nanotubos de dióxido de titânio (nt-TiO2) em diferentes concentrações (0,3, 0,6, e 0,9% em peso) quanto às suas propriedades físico-químicas, mecânicas e biológica. Duas condições de polimerização foram analisadas: autopolimerizável (grupos: AC, A03, A06 e A09) e dual (grupos: DC, D03, D06 e D09). Para análise do grau de conversão foi utilizada a espectroscopia de infravermelho com transformada de Fourier com registro do espectro nos tempos de 3, 6, 9, 12 e 15 minutos. Os picos das bandas de comprimento de onda de 1638 cm-1 e de 1608 cm-1 foram identificados para cálculo do grau de conversão. Os dados foram submetidos à ANOVA de medidas repetidas seguido de comparações múltiplas de Tukey (=0,05). A análise de sorção e solubilidade foi realizada por meio da confecção de discos de cimento resinoso (10 mm ø × 2 mm) (n=8) monitorados quanto à sua massa depois de ciclos de hidratação/desidratação. A resistência à flexão em 3 pontos e módulo de elasticidade foram mensurados por meio de barras (2 × 2 × 25 mm) de cimento resinoso (n=10) levadas à máquina universal de ensaios. Para análise de Dureza Knoop utilizou-se microdurômetro com carga de 50g /10 segundos. Nos discos de cimento resinoso de 10 mm ø × 2 mm foram realizadas 5 endentações equidistantes 0,5mm e medidas em aumento de 50×. Para resistência de união ao cisalhamento, sobre discos de zircônia sinterizados foi aplicado o cimento resinoso (n=10) nas dimensões de 3 mm ø × 2 mm. Por meio de dispositivo foram levados à máquina universal de ensaios. Os dados encontrados de sorção e solubilidade e de cada propriedade mecânica foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Exceto para resistência ao cisalhamento que se utilizou o teste de comparação de Fischer (=0,05). Para viabilidade celular (n=8) foi realizado teste de MTT apenas na condição dual. Os grupos estudados foram: DC, D03, D06, D09, CP (controle positivo), CN (controle negativo). Após 24, 48 e 72 horas os níveis de absorbâncias foram analisados por meio de espectrofotometria no leitor de ELISA. Os dados foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Os resultados mostraram que a adição de nt-TiO2, independente da concentração, aumentou os valores de grau de conversão do cimento resinoso para a condição autopolimerizável e dual em todos os tempos estudados. Já para sorção e solubilidade não houve influência nos resultados da concentração de nanotubos inseridos e da condição de polimerização. Para resistência flexural, a adição de nt-TiO2 nas concentrações de 0,3% (A03) e 0,9% (A09) resultou em dados similares ao controle na condição dual (DC). O valor médio de módulo de elasticidade aumentou com a adição de 0,9% (A09), similar a todos os grupos da condição dual, em que adição de nt-TiO2 não influenciou os resultados. A adição de 0,6% (A06 e D06) e 0,9% (A09 e D09) de nt-TiO2 ao cimento aumentou os valores de dureza quando comparado aos grupos controle (AC e DC). Para resistência de união ao cisalhamento, a concentração de 0,3% de nt-TiO2 (A03 e D03) aumentou os valores quando comparado aos grupos A06, D06, A09 e D09 porém sem diferença para os grupos controle (AC e DC). Para viabilidade celular no período de 24h, os grupos D03, D06 e D09 obtiveram resultado similar ao grupo CP, já o grupo DC apresentou valores de absorbância inferiores ao CP, usado como parâmetro de comparação. Em 48 e 72h, todos os grupos experimentais não demonstraram diferença significativa em comparação ao grupo CP. O grupo CN apresentou diferença para os demais em todos dos tempos estudados. A adição de nt-TiO2 ao cimento resinoso autoadesivo representa uma estratégia promissora para potencializar suas propriedades físico-químicas e mecânicas sem prejuízo das propriedades biológicas. / The aim of this study was to characterize the self-adhesive resin cement RelyX U200 additive, titanium dioxide nanotubes (nt-TiO2), at different concentrations (0.3%, 0.6%, and 0.9% by weight) and to determine their physicochemical, mechanical and biological properties. Two polymerization conditions were analyzed: self-curing (groups AC, A03, A06 and A09) and dual-curing (groups DC, D03, D06 and D09). To analyze the conversion degree, Fourier transform infrared spectroscopy was used, and the spectrum was recorded at 3, 6, 9, 12 and 15 minutes. The peaks of the wavelength bands, 1638 cm-1 and 1608 cm-1, were identified to calculate the degree of conversion. The data were subjected to a repeated-measures ANOVA followed by a Tukey multiple-comparison test (=0.05). The sorption and solubility analysis was performed by making resin-cement discs (10 mm ø × 2 mm) (n=8) and monitoring their masses after the hydration/dehydration cycles. The 3-point flexural strength and the modulus of elasticity of resin-cement bars (2 × 2 × 25 mm) (n=10) were measured using a universal testing machine. The Knoop microhardness was analyzed with a load of 50 g and a time of 10 seconds. On each resin cement disc, 5 equidistant indentations of 0.5 mm were made, and the measures were increased by 50×. To test bonding shear strength, resin cement was applied to sintered zirconia discs (3 mm ø × 2 mm) (n=10). The bonded discs were then taken to the universal testing machine. Their sorption, solubility and each mechanical property were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The shear strength was submitted to a Fischer comparison test (=0.05). To test cell viability (n=8), a MTT assay was performed using only the dual-curing condition. The studied groups were: DC, D03, D06, D09, CP (positive control) and CN (negative control). After 24, 48 and 72 hours, the absorbance levels were analyzed using an ELISA spectrophotometry reader. The data were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The results showed that the addition of nt-TiO2, regardless of concentration, increased the conversion degree values for the self-curing resin cement and for the dual-curing at all times studied. The sorption and solubility were not influenced by the concentration of the nanotubes or the polymerization condition. Regarding flexural strength, the addition of the nt-TiO2 in concentrations of either 0.3% (A03) or 0.9% (A09) resulted in data similar to those in the dual-curing control (DC) condition. The average modulus of elasticity increased with the addition of 0.9% nt-TiO2 (A09), and as with all the groups in the dual-curing condition, the addition of nt-TiO2 did not affect the results. The addition of either 0.6% (A06 and D06) or 0.9% (A09 and D09) of nt-TiO2 cement increased hardness values relative to the control groups (AC and DC). The group with a 0.3% concentration of nt-TiO2 (A03 and D03) showed higher bonding shear strength values than several of the groups with higher concentrations (A06, D06 and D09), but the A09 group had no difference relative to either control group (AC or DC). For cell viability in the 24-h period, the D03 D06 and D09 groups achieved a result similar to that of the CP group with significant difference to the DC group that had lower absorbance values. At the benchmarks of 48 and 72 h, and only the CN group showed a significant difference compared to others. The addition of nt-TiO2 is a promising strategy for improving the physical-chemical and mechanical properties without prejudice the biological properties.
12

Caracterização físico-química, mecânica e biológica de cimento autoadesivo aditivado com nanotubos de dióxido de titânio / Physical-chemical, mechanical and biological characterization of reinforcement self-adhesive resin cement titanium dioxide nanotubes

Carla Müller Ramos Tonello 28 November 2016 (has links)
O objetivo desse estudo foi realizar a caracterização do cimento resinoso autoadesivo RelyX U200 aditivado de nanotubos de dióxido de titânio (nt-TiO2) em diferentes concentrações (0,3, 0,6, e 0,9% em peso) quanto às suas propriedades físico-químicas, mecânicas e biológica. Duas condições de polimerização foram analisadas: autopolimerizável (grupos: AC, A03, A06 e A09) e dual (grupos: DC, D03, D06 e D09). Para análise do grau de conversão foi utilizada a espectroscopia de infravermelho com transformada de Fourier com registro do espectro nos tempos de 3, 6, 9, 12 e 15 minutos. Os picos das bandas de comprimento de onda de 1638 cm-1 e de 1608 cm-1 foram identificados para cálculo do grau de conversão. Os dados foram submetidos à ANOVA de medidas repetidas seguido de comparações múltiplas de Tukey (=0,05). A análise de sorção e solubilidade foi realizada por meio da confecção de discos de cimento resinoso (10 mm ø × 2 mm) (n=8) monitorados quanto à sua massa depois de ciclos de hidratação/desidratação. A resistência à flexão em 3 pontos e módulo de elasticidade foram mensurados por meio de barras (2 × 2 × 25 mm) de cimento resinoso (n=10) levadas à máquina universal de ensaios. Para análise de Dureza Knoop utilizou-se microdurômetro com carga de 50g /10 segundos. Nos discos de cimento resinoso de 10 mm ø × 2 mm foram realizadas 5 endentações equidistantes 0,5mm e medidas em aumento de 50×. Para resistência de união ao cisalhamento, sobre discos de zircônia sinterizados foi aplicado o cimento resinoso (n=10) nas dimensões de 3 mm ø × 2 mm. Por meio de dispositivo foram levados à máquina universal de ensaios. Os dados encontrados de sorção e solubilidade e de cada propriedade mecânica foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Exceto para resistência ao cisalhamento que se utilizou o teste de comparação de Fischer (=0,05). Para viabilidade celular (n=8) foi realizado teste de MTT apenas na condição dual. Os grupos estudados foram: DC, D03, D06, D09, CP (controle positivo), CN (controle negativo). Após 24, 48 e 72 horas os níveis de absorbâncias foram analisados por meio de espectrofotometria no leitor de ELISA. Os dados foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Os resultados mostraram que a adição de nt-TiO2, independente da concentração, aumentou os valores de grau de conversão do cimento resinoso para a condição autopolimerizável e dual em todos os tempos estudados. Já para sorção e solubilidade não houve influência nos resultados da concentração de nanotubos inseridos e da condição de polimerização. Para resistência flexural, a adição de nt-TiO2 nas concentrações de 0,3% (A03) e 0,9% (A09) resultou em dados similares ao controle na condição dual (DC). O valor médio de módulo de elasticidade aumentou com a adição de 0,9% (A09), similar a todos os grupos da condição dual, em que adição de nt-TiO2 não influenciou os resultados. A adição de 0,6% (A06 e D06) e 0,9% (A09 e D09) de nt-TiO2 ao cimento aumentou os valores de dureza quando comparado aos grupos controle (AC e DC). Para resistência de união ao cisalhamento, a concentração de 0,3% de nt-TiO2 (A03 e D03) aumentou os valores quando comparado aos grupos A06, D06, A09 e D09 porém sem diferença para os grupos controle (AC e DC). Para viabilidade celular no período de 24h, os grupos D03, D06 e D09 obtiveram resultado similar ao grupo CP, já o grupo DC apresentou valores de absorbância inferiores ao CP, usado como parâmetro de comparação. Em 48 e 72h, todos os grupos experimentais não demonstraram diferença significativa em comparação ao grupo CP. O grupo CN apresentou diferença para os demais em todos dos tempos estudados. A adição de nt-TiO2 ao cimento resinoso autoadesivo representa uma estratégia promissora para potencializar suas propriedades físico-químicas e mecânicas sem prejuízo das propriedades biológicas. / The aim of this study was to characterize the self-adhesive resin cement RelyX U200 additive, titanium dioxide nanotubes (nt-TiO2), at different concentrations (0.3%, 0.6%, and 0.9% by weight) and to determine their physicochemical, mechanical and biological properties. Two polymerization conditions were analyzed: self-curing (groups AC, A03, A06 and A09) and dual-curing (groups DC, D03, D06 and D09). To analyze the conversion degree, Fourier transform infrared spectroscopy was used, and the spectrum was recorded at 3, 6, 9, 12 and 15 minutes. The peaks of the wavelength bands, 1638 cm-1 and 1608 cm-1, were identified to calculate the degree of conversion. The data were subjected to a repeated-measures ANOVA followed by a Tukey multiple-comparison test (=0.05). The sorption and solubility analysis was performed by making resin-cement discs (10 mm ø × 2 mm) (n=8) and monitoring their masses after the hydration/dehydration cycles. The 3-point flexural strength and the modulus of elasticity of resin-cement bars (2 × 2 × 25 mm) (n=10) were measured using a universal testing machine. The Knoop microhardness was analyzed with a load of 50 g and a time of 10 seconds. On each resin cement disc, 5 equidistant indentations of 0.5 mm were made, and the measures were increased by 50×. To test bonding shear strength, resin cement was applied to sintered zirconia discs (3 mm ø × 2 mm) (n=10). The bonded discs were then taken to the universal testing machine. Their sorption, solubility and each mechanical property were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The shear strength was submitted to a Fischer comparison test (=0.05). To test cell viability (n=8), a MTT assay was performed using only the dual-curing condition. The studied groups were: DC, D03, D06, D09, CP (positive control) and CN (negative control). After 24, 48 and 72 hours, the absorbance levels were analyzed using an ELISA spectrophotometry reader. The data were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The results showed that the addition of nt-TiO2, regardless of concentration, increased the conversion degree values for the self-curing resin cement and for the dual-curing at all times studied. The sorption and solubility were not influenced by the concentration of the nanotubes or the polymerization condition. Regarding flexural strength, the addition of the nt-TiO2 in concentrations of either 0.3% (A03) or 0.9% (A09) resulted in data similar to those in the dual-curing control (DC) condition. The average modulus of elasticity increased with the addition of 0.9% nt-TiO2 (A09), and as with all the groups in the dual-curing condition, the addition of nt-TiO2 did not affect the results. The addition of either 0.6% (A06 and D06) or 0.9% (A09 and D09) of nt-TiO2 cement increased hardness values relative to the control groups (AC and DC). The group with a 0.3% concentration of nt-TiO2 (A03 and D03) showed higher bonding shear strength values than several of the groups with higher concentrations (A06, D06 and D09), but the A09 group had no difference relative to either control group (AC or DC). For cell viability in the 24-h period, the D03 D06 and D09 groups achieved a result similar to that of the CP group with significant difference to the DC group that had lower absorbance values. At the benchmarks of 48 and 72 h, and only the CN group showed a significant difference compared to others. The addition of nt-TiO2 is a promising strategy for improving the physical-chemical and mechanical properties without prejudice the biological properties.
13

Mechanical Activation of Valvular Interstitial Cell Phenotype: A Dissertation

Throm Quinlan, Angela M. 01 August 2012 (has links)
During heart valve remodeling, and in many disease states, valvular interstitial cells (VICs) shift to an activated myofibroblast phenotype which is characterized by enhanced synthetic and contractile activity. Pronounced alpha smooth muscle actin (αSMA)-containing stress fibers, the hallmark of activated myofibroblasts, are also observed when VICs are placed under tension due to altered mechanical loading in vivo or during in vitro culture on stiff substrates or under high mechanical loads and in the presence of transforming growth factor-beta1 (TGF-β1). The work presented herein describes three distinct model systems for application of controlled mechanical environment to VICs cultured in vitro. The first system uses polyacrylamide (PA) gels of defined stiffness to evaluate the response of VICs over a large range of stiffness levels and TGF-β1 concentration. The second system controls the boundary stiffness of cell-populated gels using springs of defined stiffness. The third system cyclically stretches soft or stiff two-dimensional (2D) gels while cells are cultured on the gel surface as it is deformed. Through the use of these model systems, we have found that the level of 2D stiffness required to maintain the quiescent VIC phenotype is potentially too low for a material to both act as matrix to support cell growth in the non-activated state and also to withstand the mechanical loading that occurs during the cardiac cycle. Further, we found that increasing the boundary stiffness on a three-dimensional (3D) cell populated collagen gel resulted in increased cellular contractile forces, αSMA expression, and collagen gel (material) stiffness. Finally, VIC morphology is significantly altered in response to stiffness and stretch. On soft 2D substrates, VICs cultured statically exhibit a small rounded morphology, significantly smaller than on stiff substrates. Following equibiaxial cyclic stretch, VICs spread to the extent of cells cultured on stiff substrates, but did not reorient in response to uniaxial stretch to the extent of cells stretched on stiff substrates. These studies provide critical information for characterizing how VICs respond to mechanical stimuli. Characterization of these responses is important for the development of tissue engineered heart valves and contributes to the understanding of the role of mechanical cues on valve pathology and disease onset and progression. While this work is focused on valvular interstitial cells, the culture conditions and methods for applying mechanical stimulation could be applied to numerous other adherent cell types providing information on the response to mechanical stimuli relevant for optimizing cell culture, engineered tissues or fundamental research of disease states.
14

Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014 / Load-deflection study of caliber 0.014 nickel-titanium orthodontic wires

Sathler-Zanda, Renata 03 July 2012 (has links)
PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos apinhamentos dentários. Outro objetivo foi comparar os dois meios mais utilizados de avaliação da deflexão elástica destes fios: o teste de 3 pontos e o dispositivo de simulação clínica. MATERIAL E MÉTODOS: Foram avaliados 11 grupos de fios de liga predominantemente de níquel-titânio, calibre 0,014, de 6 marcas diferentes (Abzil convencional e termoativado; GAC convencional e termoativado; Morelli convencional e termoativado; Ormco CuNiTi; Orthometric convencional e termoativado e Orthosource convencional e termoativado), em teste de deflexão elástica, nas deflexões de 0,5; 1; 2 e 3mm. Uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N foi utilizada e, como protocolo, foi seguida a norma ISO 15.841. Para a análise estatística dos resultados foram utilizados os testes: Kolmogorov-Smirnov, para conferir se havia normalidade; teste t independente, para comparação dos resultados do teste de 3 pontos e dos resultados do dispositivo; e o teste ANOVA seguido do teste de Tukey, para comparações entre grupos. RESULTADOS: Houve diferença estatística entre os resultados gerados pelo teste de 3 pontos e os gerados pelo dispositivo. Por ser o teste indicado pela norma ISO citada, somente os resultados do teste de 3 pontos foram considerados. Todos os fios estudados apresentaram pseudoelasticidade em uma faixa de variação de força de até 40cN. Os grupos Abzil convencional, GAC convencional, Morelli termoativado, Ormco CuNiTi e Orthometric convencional apresentaram força dentro de uma faixa considerada ótima para a indução da movimentação dentária (50cN-100cN). Os fios termoativados liberaram forças mais leves que seus pares convencionais. CONCLUSÕES: Dentre os grupos estudados, aqueles que apresentaram pseudoelasticidade, forças dentro de uma faixa considerada ótima e homogeneidade de amostra, foram os grupos Morelli termoativado e Ormco CuNiTi. / OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of orthodontic nickel-titanium wires, caliber 0.014, of 6 different brands (Abzil conventional and heat-activated; GAC conventional and heat-activated; Morelli conventional and heat-activated; Ormco CuNiTi; Orthometric conventional and heat-activated and Orthosource conventional and heat-activated) were tested by bending test, at deflections of 0.5; 1; 2 and 3mm. A universal testing machine INSTRON 3342 with a 10N load cell was used and, in order to standardize the tests, the ISO 15.841 regulation was followed. Statistical analysis was performed using the subsequent tests: Kolmogorov-Smirnov to verify normality; independent t test to compare the results of the 3-point test and the results derived from the device, and ANOVA followed by the Tukey test for intergroup comparisons. RESULTS: There were significant differences between the results of the 3-point test and the device. As indicated by the ISO regulation, only the results from the 3-point bending test were considered. All groups were classified as pseudoelastic, within a load range of 40cN, at maximum. The groups Abzil conventional, GAC conventional, Morelli heat-activated, Ormco CuNiTi and Orthometric conventional released load within optimum range (50cN-100cN). Heatactivated wires released lower load compared to conventional wire of the same brand. CONCLUSIONS: Among the groups evaluated those that presented pseudoelasticity, load within a range considered optimal, in a homogeneous manner, were Morelli heat-activated and Ormco CuNiTi.
15

Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014 / Load-deflection study of caliber 0.014 nickel-titanium orthodontic wires

Renata Sathler-Zanda 03 July 2012 (has links)
PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos apinhamentos dentários. Outro objetivo foi comparar os dois meios mais utilizados de avaliação da deflexão elástica destes fios: o teste de 3 pontos e o dispositivo de simulação clínica. MATERIAL E MÉTODOS: Foram avaliados 11 grupos de fios de liga predominantemente de níquel-titânio, calibre 0,014, de 6 marcas diferentes (Abzil convencional e termoativado; GAC convencional e termoativado; Morelli convencional e termoativado; Ormco CuNiTi; Orthometric convencional e termoativado e Orthosource convencional e termoativado), em teste de deflexão elástica, nas deflexões de 0,5; 1; 2 e 3mm. Uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N foi utilizada e, como protocolo, foi seguida a norma ISO 15.841. Para a análise estatística dos resultados foram utilizados os testes: Kolmogorov-Smirnov, para conferir se havia normalidade; teste t independente, para comparação dos resultados do teste de 3 pontos e dos resultados do dispositivo; e o teste ANOVA seguido do teste de Tukey, para comparações entre grupos. RESULTADOS: Houve diferença estatística entre os resultados gerados pelo teste de 3 pontos e os gerados pelo dispositivo. Por ser o teste indicado pela norma ISO citada, somente os resultados do teste de 3 pontos foram considerados. Todos os fios estudados apresentaram pseudoelasticidade em uma faixa de variação de força de até 40cN. Os grupos Abzil convencional, GAC convencional, Morelli termoativado, Ormco CuNiTi e Orthometric convencional apresentaram força dentro de uma faixa considerada ótima para a indução da movimentação dentária (50cN-100cN). Os fios termoativados liberaram forças mais leves que seus pares convencionais. CONCLUSÕES: Dentre os grupos estudados, aqueles que apresentaram pseudoelasticidade, forças dentro de uma faixa considerada ótima e homogeneidade de amostra, foram os grupos Morelli termoativado e Ormco CuNiTi. / OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of orthodontic nickel-titanium wires, caliber 0.014, of 6 different brands (Abzil conventional and heat-activated; GAC conventional and heat-activated; Morelli conventional and heat-activated; Ormco CuNiTi; Orthometric conventional and heat-activated and Orthosource conventional and heat-activated) were tested by bending test, at deflections of 0.5; 1; 2 and 3mm. A universal testing machine INSTRON 3342 with a 10N load cell was used and, in order to standardize the tests, the ISO 15.841 regulation was followed. Statistical analysis was performed using the subsequent tests: Kolmogorov-Smirnov to verify normality; independent t test to compare the results of the 3-point test and the results derived from the device, and ANOVA followed by the Tukey test for intergroup comparisons. RESULTS: There were significant differences between the results of the 3-point test and the device. As indicated by the ISO regulation, only the results from the 3-point bending test were considered. All groups were classified as pseudoelastic, within a load range of 40cN, at maximum. The groups Abzil conventional, GAC conventional, Morelli heat-activated, Ormco CuNiTi and Orthometric conventional released load within optimum range (50cN-100cN). Heatactivated wires released lower load compared to conventional wire of the same brand. CONCLUSIONS: Among the groups evaluated those that presented pseudoelasticity, load within a range considered optimal, in a homogeneous manner, were Morelli heat-activated and Ormco CuNiTi.

Page generated in 0.1116 seconds