• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 8
  • 8
  • 8
  • 8
  • 7
  • 2
  • 1
  • Tagged with
  • 11
  • 11
  • 11
  • 7
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Otimização dos parâmetros para obtenção de nanotubos em Ti-Cp por anodização eletroquímica e aplicação na liga experimental Ti-35Nb-7Zr /

Rosa, Jorge Luiz, 1968- January 2013 (has links)
Orientador: Roberto Zenhei Nakazato / Coorientador: Alain Laurent Marie Robin / Banca: Messias Borges Silva / Banca: Ana Paula Rosifini Alves Claro / Banca: Gilbert Silva / Banca: Jeferson Fabrício Cardoso Lins / Resumo: Este estudo tem com objetivo principal buscar a otimização do processo de obtenção de nanotubos auto-organizados na superfície plana do Ti-Cp pela técnica de anodização eletroquímica e a aplicação da condição experimental otimizada nas superfícies da liga experimental Ti-35Nb-7Zr e de um implante comercial de Ti. No estudo de otimização dos principais fatores do processo (eletrólito, tempo e potencial) foi utilizada a ferramenta de planejamento de experimento - DOE. A formação da camada de titânia foi observada por microscopia eletrônica de varredura de alta resolução-SEM/FEG e espectroscopia de energia de raios X. O tratamento térmico para estabilização da fase cristalina dos óxidos, realizado a 300, 400 e 500oC, revelou a formação de anatase a partir de 400oC, porém acima desta temperatura ocorre o fechamento e coalescência dos nanotubos. Ensaios eletroquímicos realizados em solução de Ringer mostraram que superfícies de titânio recobertas com nanotubos de TiO2 são menos resistentes à corrosão do que o titânio como recebido. Através do emprego do DOE foi possível verificar que a melhor condição de ajuste experimental na obtenção de nanotubos auto-organizados para o Ti-Cp foi o meio glicerol-H2O/NH4F, e com controle dos fatores potencial, tempo e concentração de NH4F obteve-se o óxido com as características desejadas. O potencial foi o fator que apresentou maior influência no processo. A aplicação da melhor condição experimental sobre o implante comercial de Ti possibilitou a formação de nanotubos com pequena alteração na morfologia. Já, sobre a superfície da liga Ti-35Nb-7Zr foram observados nanotubos com alterações significativas na morfologia e dimensões diferentes da observada sobre o Ti-Cp / Abstract: This study has as its main objective the optimization of the process of obtaining nanotubes self-assembled on the Ti-Cp flat surface by electrochemical anodization technique and application of this experimental condition on the surfaces of the Ti-35Nb-7Zr experimental alloy and commercial Ti implant. In the optimization study of main factors of the process (electrolyte, anodization time and potential) was used the method Design of Experiments - DOE. The formation of the layer of titania was observed by Field Emission Gun Scanning Electron Microscopy (FEG-SEM) and Energy dispersive X-ray spectroscopy (EDS). The heat treatment used to stabilize the crystalline phase of the oxides conducted at 300, 400 and 500°C revealed the formation of anatase from 400oC, but above this temperature occurs closing and coalescence of the nanotubes. Electrochemical tests performed in Ringer's solution showed that titanium surfaces coated with TiO2 nanotubes are less corrosion resistant than titanium as received. By employing the DOE was possible to verify that the best experimental setting condition in obtaining self-organized nanotubes for Ti-Cp was the glicerol-H2O/NH4F electrolyte, and controlling the factors, potential, anodization time and concentration of NH4F, was obtained the oxide with the desired characteristics. The potential was the factor that most influenced the process. The application of the best experimental condition on commercial Ti implant enabled the formation of nanotubes with small change in morphology. But on the Ti-35Nb-7Zr alloy surface were observed significant changes in nanotubes morphology and different dimensions from that observed for Ti-Cp / Doutor
2

Influência do Shot-Peening e da anodização crômica na resistência à fadiga da liga de alumínio 7475-T7351 /

Castro, Valéria Alves de. January 2018 (has links)
Orientador: Valdir Alves Guimarães / Banca: Marcelino Pereira do Nascimento / Banca: Gilbert Silva / Resumo: A influência do Shot-Peening e da anodização na resistência à fadiga vem sendo estudada ao longo dos anos, pois são processos amplamente utilizados nas indústrias, em especial na aeronáutica. A análise desse comportamento é extremamente necessária, pois as peças de aeronaves sofrem esforços cíclicos e são expostas ao ambiente corrosivo, que além de reduzir o ciclo de vida, são também prejudiciais à segurança de voo. Em função disso os materiais devem ter boa resistência à fadiga e à corrosão. Para melhorar essas propriedades são aplicados os processos de Shot-Peening e anodização, contudo é essencial que os parâmetros e materiais sejam estudados e ensaiados a fim de se obter um resultado efetivo. Em vista disso, esta pesquisa tem por objetivo avaliar a influência do Shot-Peening e da anodização crômica na resistência à fadiga do alumínio 7475-T7351. O ensaio de fadiga foi realizado com carga axial, frequência de 20 Hz e razão de carga 0,1. A intensidade Almen foi de 0.006 A - 0.010 A e as esferas do jateamento foram de aço. Os resultados dos ensaios das amostras com Shot-Peening seguido de anodização crômica apresentaram redução na resistência à fadiga. Essa redução foi atribuída às tensões residuais de tração e as características da camada de óxido geradas pela anodização e aos parâmetros do Shot-Peening que não induziu tensão residual de compressão o suficiente para retardar a propagação das trincas. O aumento da rugosidade, que é inerente ao processo de Shot-Peening, traba... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The influence of Shot-Peening and anodization on the fatigue strength has been studied over the years because these processes are broadly used in industries, especially in aeronautics. The analysis of this behavior is extremely necessary due the cyclic loading of the parts and exposure to corrosive environment, which in addition to reducing the life cycle of an aircraft are also detrimental to flight safety. Due to this, the materials must have good fatigue strength and corrosion resistance. To improve these properties, the Shot-Peening and anodization processes are applied, however it is essential that the parameters and materials be studied and tested in order to obtain an effective result. Therefore, this research has the objective of evaluating the influence of Shot-Peening and chromic anodization on the fatigue strength of 7475-T7351 aluminum alloy. The fatigue test was performed with axial load, frequency of 20 Hz and load ratio 0.1. The Almen intensity was 0.006 A - 0.010 A and the material of spheres was steel. The results of the Shot-Peening specimens followed by chromic anodization treatment show a reduction of the fatigue strength. This reduction is due to residual tensile stress and the characteristics of the oxide layer generated by the anodization treatment and to the Shot-Peening parameters that did not induce residual compression stress enough to delay the crack propagation. The increased roughness, which is inherent in the process, has worked as a stress conc... (Complete abstract click electronic access below) / Mestre
3

Desenvolvimento de superfícies nanoestruturadas em titânio e ligas de titânio-zircônio /

Targino, Juarez. January 2017 (has links)
Orientador: Luís Rocha / Banca: José Humberto Dias da Silva / Banca: Carlos Nelson Elias / Resumo: O titânio e suas ligas são amplamente utilizados em diversas aplicações biomédicas devido às suas propriedades, nomeadamente a alta resistência à corrosão e elevada biocompatibilidade. A elevada resistência à corrosão advém da capacidade de o titânio formar na sua superfície uma camada de óxido amorfo estável com espessura de alguns nanômetros (filme passivo). As propriedades dos filmes passivos nas ligas de titânio são sensíveis à microestrutura (fases presentes e sua proporção relativa) e às condições ambientais que levam à formação desse filme. Por outro lado, a espessura, morfologia e composição do filme de óxido nativo podem ser manipuladas de forma a obter propriedades diferentes. O presente trabalho teve como objetivo o desenvolvimento de superfícies nanoestruturadas nanotubos em titânio comercialmente puro e na liga de Ti-2,5Zr através da técnica de anodização. Fez-se a análise da influência da voltagem aplicada à célula eletrolítica e do tempo de anodização nas características das superfícies produzidas (morfologia e estrutura). Os mecanismos de formação e crescimento dos nanotubos de dióxido de titânio (TiO2) foram analisados em função da voltagem e do tempo de anodização, os resultados obtidos mostraram que a morfologia da superfície, nomeadamente o diâmetro dos nanotubos formados, é fortemente dependente tanto das condições de anodização quanto do substrato a partir do qual os nanotubos são formados / Abstract: Titanium and is alloys are widely used in various biomedical applications because of their properties, namely high corrosion resistance and high biocompatibility. The high corrosion resistance results from the ability of the titanium to form on its surface a layer of stable amorphous oxide with a thickness of a few nanometers (passive film). The properties of the passive films in the titanium alloys are sensitive to the microsctructure (present phases and their relative proportion) and the environmental conditions that lead to the formulation of this film. On the other hand, the thickness, morphology and composition of the native oxide film can be mainipulated in order to obtain different properties. The present work aimed to the development of nano-structured nanotube surfaces in commercially pure titanium and Ti- 2,5Zr alloy by anodizing technique. The influence of the voltage applied to the electrolytic cell and the anodizing time on the characteristic of the produced surfaces (morphology and structure) were analyzed. The formation and growth mechanisms of titanium dioxide (TiO2) nanotubes were analyzed as a function of voltage and time of anodization, the results showed that the surface morphology, namely the diameter of the nanotubes formed, is strongly dependent on both the conditions of anodizing and of the substrate from which the nanotubes are formed / Mestre
4

Otimização dos parâmetros para obtenção de nanotubos em Ti-Cp por anodização eletroquímica e aplicação na liga experimental Ti-35Nb-7Zr / Optimization of parameters in obtaining nanotubes on Ti-Cp by electrochemical anodization and application of the Ti-35Nb-7Zr experimental alloy

Rosa, Jorge Luiz [UNESP] 28 June 2013 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:24:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-06-28. Added 1 bitstream(s) on 2015-12-10T14:31:00Z : No. of bitstreams: 1 000852073.pdf: 4812797 bytes, checksum: 6ab33b7c1d6d311973f9828d1ac35bde (MD5) / Este estudo tem com objetivo principal buscar a otimização do processo de obtenção de nanotubos auto-organizados na superfície plana do Ti-Cp pela técnica de anodização eletroquímica e a aplicação da condição experimental otimizada nas superfícies da liga experimental Ti-35Nb-7Zr e de um implante comercial de Ti. No estudo de otimização dos principais fatores do processo (eletrólito, tempo e potencial) foi utilizada a ferramenta de planejamento de experimento - DOE. A formação da camada de titânia foi observada por microscopia eletrônica de varredura de alta resolução-SEM/FEG e espectroscopia de energia de raios X. O tratamento térmico para estabilização da fase cristalina dos óxidos, realizado a 300, 400 e 500oC, revelou a formação de anatase a partir de 400oC, porém acima desta temperatura ocorre o fechamento e coalescência dos nanotubos. Ensaios eletroquímicos realizados em solução de Ringer mostraram que superfícies de titânio recobertas com nanotubos de TiO2 são menos resistentes à corrosão do que o titânio como recebido. Através do emprego do DOE foi possível verificar que a melhor condição de ajuste experimental na obtenção de nanotubos auto-organizados para o Ti-Cp foi o meio glicerol-H2O/NH4F, e com controle dos fatores potencial, tempo e concentração de NH4F obteve-se o óxido com as características desejadas. O potencial foi o fator que apresentou maior influência no processo. A aplicação da melhor condição experimental sobre o implante comercial de Ti possibilitou a formação de nanotubos com pequena alteração na morfologia. Já, sobre a superfície da liga Ti-35Nb-7Zr foram observados nanotubos com alterações significativas na morfologia e dimensões diferentes da observada sobre o Ti-Cp / This study has as its main objective the optimization of the process of obtaining nanotubes self-assembled on the Ti-Cp flat surface by electrochemical anodization technique and application of this experimental condition on the surfaces of the Ti-35Nb-7Zr experimental alloy and commercial Ti implant. In the optimization study of main factors of the process (electrolyte, anodization time and potential) was used the method Design of Experiments - DOE. The formation of the layer of titania was observed by Field Emission Gun Scanning Electron Microscopy (FEG-SEM) and Energy dispersive X-ray spectroscopy (EDS). The heat treatment used to stabilize the crystalline phase of the oxides conducted at 300, 400 and 500°C revealed the formation of anatase from 400oC, but above this temperature occurs closing and coalescence of the nanotubes. Electrochemical tests performed in Ringer's solution showed that titanium surfaces coated with TiO2 nanotubes are less corrosion resistant than titanium as received. By employing the DOE was possible to verify that the best experimental setting condition in obtaining self-organized nanotubes for Ti-Cp was the glicerol-H2O/NH4F electrolyte, and controlling the factors, potential, anodization time and concentration of NH4F, was obtained the oxide with the desired characteristics. The potential was the factor that most influenced the process. The application of the best experimental condition on commercial Ti implant enabled the formation of nanotubes with small change in morphology. But on the Ti-35Nb-7Zr alloy surface were observed significant changes in nanotubes morphology and different dimensions from that observed for Ti-Cp
5

Avaliação da osteointegração em implantes da liga de Tii7,5Mo com tratamento de superfície por anodização /

Tupinambá, Rogerio Amaral. January 2019 (has links)
Orientador: Ana Paula Risifni Alves Claro / Coorientador: Ana Lúcia do Amaral Escada / Banca: Durval Rodrigues Júnior / Banca: Cristiane Aparecida Assis Claro / Banca: Ronaldo Spezia Nunes / Resumo: O objetivo deste estudo in vivo foi avaliar as propriedades de resposta óssea da liga de Ti7,5Mo usinada em minimplantes com tratamento de superfície por anodização e compara-la, com sua versão não tratada e com a liga de Ti-CP em sua apresentação comercial, tratada por jateamento e ataque ácido, em relação às suas propriedades de osteointegração. Os minimplantes do Grupo tratado de Ti7,5Mo foram anodizados em eletrólito de NH4F por 24h e em seguida calcinados a 450ºC por 1h. As amostras foram divididas em três Grupos, Ti-CP com tratamento de superfície por jateamento seguido de ataque ácido (n=5), Ti7,5Mo usinadas (n=5) e Ti7,5Mo anodizado para crescimento de nanotubos de TiO2 (n=6). Para caracterização das amostras foram realizados a espectroscopia Raman, difração de raios X, perfilometria ótica e microscopia eletrônica de varredura. As análises histomorfométricas para determinação do BIC (bone to implant contact) e do BAFO (bone area fraction occupancy) foram realizadas após implantação das amostras de cada Grupo na tíbia de ratos Wistar sacrificados após 4 semanas. A análise estatística por meio do teste de ANOVA de 1 fator demonstrou haver diferença estatística significante apenas entre os Grupos para o BIC; o teste Tukey para avaliação do BIC demonstrou haver diferença estatística significante somente entre o Grupo Ti7,5Mo anodizado em relação ao Grupo Ti-CP em apresentação comercial; não foram detectadas diferenças estatísticas significantes para o BAFO entre os Grupos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this in vivo study was to evaluate the bone response of the Ti7,5Mo alloy machined in minimplants with surface treatment by anodization and compare it, with its untreated version and with the Ti-CP alloy in its commercial presentation, gritblasted and acid-etched. The Ti7,5Mo minimplants of the treated group were anodised in a NH4F electrolyte for 24h and then calcinated at 450ºC for 1h. The samples were divided into three groups, Ti-CP with surface treatment by blasting followed by acid-etched (n=5), Ti7, 5Mo machined (n=5) and Ti7, 5Mo anodized for growth of TiO2 nanotubes (n=6). To characterize the samples, Raman spectroscopy, X-ray diffraction, optical perfilometry and scanning electron microscopy (SEM) were performed. The Histomorphometric analysis for determination of the BIC (bone to implant contact) and BAFO (bone area fraction occupancy) were performed after the tibia implantation of the samples of each group in Wistar rats sacrificed after 4 weeks. The statistical analysis using the 1-factor ANOVA test showed statistically significant difference only for BIC amongst groups, Turkey test showed statistically significant difference for the evaluation of BIC only between the group Ti7, 5Mo anodized in relation to the Ti-CP group in commercial presentation, Turkey test did not detect significant statistical difference for BAFO among the groups. Pearson test did not detect direct correlation between BIC and BAFO values. The Ti7,5Mo samples with anodised s... (Complete abstract click electronic access below) / Doutor
6

Modificação da superfície da liga experimental Ti10Mo8Nb empregando oxidação anódica : estudos in vitro /

Carobolante, João Pedro Aquiles. January 2017 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Banca: Claudia Eliana Bruno Marino / Banca: Carlos Roberto Grandini / Resumo: Titânio e suas ligas são amplamente empregados em aplicações biomédicas, devido a sua biocompatibilidade e excelentes propriedades de volume, como resistência mecânica. As ligas de titânio tipo β com baixo módulo de elasticidade, como Ti10Mo8Nb, são indicadas para amenizar o efeito "stress shielding", característico da interface implante/osso. No entanto, quando materiais bioinertes são inseridos no corpo humano não induzirão uma resposta específica. As técnicas de modificação de superfície, como crescimento de nanoestruturas de TiO2, são utilizadas para alterar as propriedades de superfície desses materiais permitindo melhor resposta. O objetivo dessa pesquisa é a modificação de superfície da liga experimental Ti10Mo8Nb a partir do crescimento de nanoestruturas de TiO2. Os lingotes da liga experimental Ti10Mo8Nb foram obtidos a partir da fusão dos metais puros em forno a arco voltaico. A oxidação anódica potenciostática foi realizada utilizando um eletrólito formado por glicerina e H2O (1:1, em vol.) com adição de 2,7 % (m/v) de NH4F sob 20 V durante 3 h, a temperatura ambiente. Após o tratamento as amostras foram calcinadas. A superfície da liga foi analisada por microscopia eletrônica de varredura (MEV), difração de raios X (DRX), ângulo de contato, medidas da energia de superfície, espectroscopia de raios X por dispersão em energia (XPS). Estudos in vitro, como adesão celular e bacteriana, foram realizados para avaliar a resposta desse tratamento. A liga Ti10Mo8Nb apresen... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium and its alloys have been widely used as biomedical material due their biocompatibility and excellent bulk properties, such as mechanical strength. β titanium alloys with low modulus of elasticity, such as Ti10Mo8Nb, are suitable to relieve the stress shielding effect that occurs in the interface implant/bone. However, when these materials are inserted inside human body the surface properties will not induce a specific response. Surface modifications techniques can be used for change the inert surface of these alloys, e.g. TiO2 nanostructure growth by using anodic oxidation. The purpose of this research is the surface modification of Ti10Mo8Nb experimental alloy by using TiO2 nanostruture growth. Ingots of Ti10Mo8Nb experimental alloy were produced by fusion from sheets of molybdenum, niobium and titanium commercially pure in arc melting furnace under argon atmosphere. The potentiostatic anodic oxidation was performed using an electrolyte formed of glycerol and H2O (1: 1 by vol.) with addition of 2.7% (w/v) NH4F under 20 V for 3 h at room temperature. After the surface treatment, the samples were annealing. The surface of the alloy was analyzed by scanning electron microscopy (SEM), X-ray diffraction (XRD), contact angle, surface energy measurements, energy dispersive X-ray spectroscopy (XPS). In vitro studies, such as cell and bacterial adhesion, were performed to evaluate the response of this treatment. The Ti10Mo8Nb alloy exhibited beta phase after the processing, and also occurred a decrease in β-transus temperature. After the surface treatment a nanoporous layer of TiO was obtained. The anatase phase was found in the annealed samples (450 °C for 3 hours). In vitro analyzes showed cell growth viability and decreased bacterial proliferation due to larget specific surface area / Mestre
7

Avaliação do desempenho do óxido de alumínio com tratamento de superfície como dielétrico para capacitores MIS e OFETs /

Silva, Marcelo Marques da. January 2017 (has links)
Orientador: Neri Alves / Banca: Francisco Trivinho Strixino / Banca: Clarissa De Almeida Olivati / Banca: José Alberto Giacometti / Resumo: Foi realizado um estudo sobre as propriedades elétricas de filmes finos de óxido de alumínio (Al2O3) obtidos por anodização em solução eletrolítica preparada com ácido tartárico, etileno glicol e água. Filmes de Al2O3 com espessuras entre 20 e 70 nm foram crescidos sobre camadas de alumínio as quais foram depositadas por evaporação em vácuo sobre lâminas de vidro. Utilizou-se o processo de anodização em duas etapas, sendo que na primeira etapa aplica-se uma corrente constante de 0,48 mA/cm2 e monitora a tensão até alcançar o valor final, programado conforme a espessura desejada; e então, na segunda etapa, mantem-se se a tensão final durante 2 minutos, enquanto mede-se a corrente. Os filmes de Al2O3 apresentam constante dielétrica média de aproximadamente sete (ε = 7), tan δ da ordem de 10-3 e resistividade elétrica da ordem de 1013 cm. Estudou-se o efeito do tratamento de superfície pela a deposição de monocamadas dos silanos, octadecil triclorosilano (OTS), hexametildisilazano (HMDS) e do ácido fosfônico (OPA) nas características elétricas. O tratamento com HMDS se mostrou o mais efetivo, diminuindo a corrente de fuga e aumentando campo de ruptura dielétrica. Também foi estudado o efeito do recobrimento, da superfície dos filmes de Al2O3, com filmes dos polímeros isolantes poliestireno (PS), polivinil álcool (PVA), fluoreto de polivinilideno (PVDF) e polimetilmetacrilato (PMMA). A deposição de um filme de PMMA foi a que apresentou os melhores resultados, c... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A study about electric properties of aluminum oxide (Al2O3) obtained by anodization of aluminum in a electrolytic solution prepared with tartaric acid, ethylene glycol and water was performed. Thin Al2O3 films from 20 to 70 nm were grown on aluminum layer which were deposited on glass slides by vacuum metallization. It was used the anodization process in two stages, being that in first stage applies a constant current of 0,48 mA/cm2 and monitory the voltage until reach the final value, programmed in according to the desired thickness; and in the second stage, the final voltage is maintained for two minutes, while the current is measured. The Al2O3 films present medium dielectric constant about seven (ε = 7), tan δ in order of 10-3 and resistivity in order of 1013 cm. It was studied the surface treatment effect by monolayers depositions of octadecyl trichlorosilane (OTS), hexamethyldisilazane (HMDS) and phosphonic acid (OPA) on the electrical characteristics. The HMDS treatment proved to be the most effective, reducing the leakage current and increasing the dielectric rupture field. The effect of the addition of polystyrene (PS), polyvinyl alcohol (PVA), polyvinylidene fluoride (PVDF) and polymethylmethacrylate (PMMA) films on the oxide surface was also studied. The deposition of a PMMA film presented the best results, with reduction of the leakage current around two orders of magnitude in relation to pristine oxide. Devices with metal-insulator-semiconducto... (Complete abstract click electronic access below) / Doutor
8

Incorporação de clorexidina na superfície da liga Ti-7,5Mo após o crescimento de nanotubos de TiO2 /

Oliveira, Liliane Lelis de. January 2016 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Coorientadora: Ana Lúcia do Amaral Escada / Banca: Roberto Zenhei Nakazato / Banca: Rodney Bertazzoli / Resumo: O maior desafio no desenvolvimento de materiais para aplicações biomédicas é fazer com que estes tenham uma boa resposta e interação com o meio quando inseridos no corpo. Estudos sobre a topografia de superfície mostram que nanotubos de TiO2 podem contribuir para uma melhor adesão celular pois auxiliam a osseointegração e ancoragem óssea, entretanto essa mesma estrutura de superfície pode induzir o acúmulo e proliferação de bactérias na superfície do implante causando infecções e até mesmo a perda do implante. Nesse trabalho foi estudada a incorporação, ação antibactericida e fungicida da clorexidina na superfície da liga Ti-7,5Mo após o crescimento de nanotubos de TiO2 por oxidação anódica. As amostras foram divididas em dois grupos de acordo com o potencial de anodização de 10V e 20V com tempo de permanência de 24 horas, seguido de calcinação a 450ºC por 1 hora e resfriamento no forno. A partir destes procedimentos foram utilizadas técnicas de caracterização da superfície: Microscopia eletrônica de varredura (MEV) e espectroscopia de energia dispersiva (EDS) para analisar a morfologia da superfície tal como a composição química do filme formado. O ângulo de contato foi medido para analisar a molhabilidade da superfície do material e o ensaio eletroquímico mostrou o comportamento do material em meio SBS. A clorexidina foi incorporada na superfície por imersão por 30 minutos e se mostrou um bom agente bactericida e antifúngico em ação contra S. Aureus e Candida em estudos in ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The challenge when developing materials for biomedical applications is to ensure that they have a good response and interaction when in the body. Studies about the surface topography show that TiO2 nanotubes can bring a better cell adhesion because they help osseointegration and bone anchorage, however, this same surface structure can induce the accumulation and bacteria proliferation in the implant surface causing infections and even loss of the implant. This study brings the incorporation and bactericidal action of chlorhexidine on the surface of Ti-alloy 7,5Mo after growth of TiO2 nanotubes by anodic oxidation. The samples weregrouped according to the anodizing potential of 10V and 20V with time to 24 hours stay, followed by calcination at 450 ° C for 1 hour and cooling into the oven. From these procedures were used as surface characterization techniques: scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) to examine the surface morphology such as the chemical composition of the film. The contact angle was measured to analyze the surface wettability of the material and the electrochemical assay showed the behavior of the material in the middle of SBS. Chlorhexidine was incorporated into the surface by immersing for 30 minutes and showed a good bactericide and antifungal action against S. Aureus and Candida in vitro. / Mestre
9

Sequenciamento da produção em uma área de tratamento de superfície na indústria aeronáutica /

Schmidt, Paulo Alberto Misfeldt. January 2019 (has links)
Orientador: José Roberto Dale Luche / Coorientador: Aneirson Francisco da Silva / Banca: Fernando Augusto Silva Marins / Banca: Fabricio Maciel Gomes / Resumo: A programação da produção é uma questão muito importante em qualquer empresa de manufatura. Neste trabalho, foi desenvolvido um modelo de programação linear inteira mista para programar a produção de uma área de tratamento de superfície em uma empresa do setor aeronáutico. Uma breve descrição dos processos envolvidos é apresentada. Otimizar o planejamento diário da área de tratamento de superfície não é uma atividade simples, diversas restrições devem ser consideradas no modelo, como o tipo da liga de matéria-prima, a capacidade dos tanques e das gancheiras. Os resultados de planos diários de produção obtidos pelo modelo possuem a combinação ótima de produtos a serem fabricados utilizando os recursos disponíveis em sua capacidade máxima e por consequência aumentando a produtividade da área. Questões técnicas dos processos foram levadas em consideração como restrições uma vez que os produtos foram homologados junto aos fabricantes das aeronaves. Foram realizados experimentos com trinta instâncias reais e outras trinta com demanda acumulada. Os resultados alcançados pelo modelo proposto foram muito superiores quando comparados à prática da empresa, para se ter uma ideia, no período em que foi registrada a menor diferença, o modelo mostra que é possível produzir mais que o dobro do que a empresa produziu com os mesmos recursos, evidenciando que há capacidade produtiva disponível para absorver novos produtos junto aos clientes atuais e futuros / Abstract: Production scheduling is a very important issue in any manufacturing company. In this work, a mixed integer linear programming model was developed to program the production of a surface treatment area in an aeronautical company. A brief description of the processes involved is presented. Optimizing the daily planning of the surface treatment area is not a simple activity, several constraints must be considered in the model, such as the type of raw material alloy, the capacity of the tanks and the glaciers. The results of daily production plans obtained by the model have the optimal combination of products to be manufactured using available resources at their maximum capacity and consequently increasing the area productivity. Technical issues of the processes were taken into consideration as restrictions since the products were homologated with the aircraft manufacturers. Experiments are performed with thirty real instances and another thirty with accumulated demand. The results achieved by the proposed model were much higher when compared to the company's practice, so as to have an idea, in the period when the smallest difference was registered, the model shows that it is possible to produce more than double what the company produced with same resources, showing that there is production capacity available to absorb new products with current and future customers / Mestre
10

Caracterização eletroquímica de filmes anódicos de titânio grau 2 visando aplicações biomédicas /

Torres, Dimas Luiz. January 2013 (has links)
Orientador: Heloisa Andréa Acciari / Coorientador: Eduardo Noberto Codaro / Banca: Rosinei Batista Ribeiro / Banca: Leide Lili Gonçalves da Silva Kostov / Resumo : Diferentes tiposde tratamentos com titânio têm sido propostos com a finalidade de promover o desempenho biológico dos implantes por tornar a superfície bioativa. Muitos metais quando expostos à atmosfera sofrem um processo deoxidação que conduz à formação de uma fina camada de óxidos sobre a sua superfície. Estes produtos da reação podem proteger o metal de posterior corrosão. O processo eletroquímico de anodização de metais permite a obtenção de uma camada de óxido relativamente fina e mais densa que aquela formada naturalmente na atmosfera. No caso do titânio, esta camada tem sido utilizada para favorecer a nucleação de apatitas e, por conseguinte, a osseo integração. Neste estudo foi investigada a influência da concentração do eletrólito e do tempo de anodização na morfologia e no comportamento eletroquímico de filmes anódicos formados sobre titânio comercialmente puro. Métodos eletroquímicos e de análise de superfície foram usados para caracterizar as superfícies modificadas de titânio. Verificou-se que, tanto a concentração doeletrólito como o tempo de anodização afetam o crescimento e as características protetoras dos filmes em um meio que simula o soro fisiológico. Nos perfis potencio dinâmicos, observou-se que os valores dos potenciais de rompimento de filme passivo são afetados pelo tempo de anodização. Variações nos espectros de impedância foram associadas com um aumento no número de defeitos destes filmes / Abstract: Different types of treatments have been proposed with titanium in order to promote the biological performance of implants for making bioactive surface. Many metals when exposed to the atmosphere undergo an oxidation process leading to the formation of a thin oxide layer on its surface. These reaction products can protect the metal from corrosion. The electrochemical process anodizing allows metals to obtain a relatively thin oxide layer and more to denser than formed naturally in the atmosphere. In the case of titanium, this layer has been used to promote nucleation of apatite, and therefore the osseointegração. In this study, it was investigated the influence of electrolyte concentration and the anodizing time on the morphology and electrochemical behavior of anodic films formed on commercially pure titanium. Electrochemical method sand surface analysis were used to characterize the surface modification of titanium. It was found that both the concentration of the electrolyte as anodizing time, affect the growth and protective characteristics of the films in a medium that simulates the physiological serum. In potentiodynamic profiles, it was observed that the values of the potential disruption of the passive film are affected by the time of anodizing. Variations in the impedance spectra were associated with an increase in the number of defects of the films / Mestre

Page generated in 0.0916 seconds