• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 81
  • 23
  • 14
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 164
  • 57
  • 51
  • 50
  • 40
  • 28
  • 19
  • 16
  • 15
  • 15
  • 15
  • 15
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Fabrication and characterization of dexibuprofen nanocrystals using microchannel fluidic reactor

06 November 2019 (has links)
Yes / Purpose: Dexibuprofen is an enantiomer of ibuprofen with low bioavailability which results from its hydrophobic nature. Nanosuspensions have developed a podium to solve the in vitro dissolution problem that frequently occurs in current research. Materials and methods: The drug and polymer solutions were mixed in a microchannel fluid reactor and the successive embryonic nanosuspension was decanted into a vial having the polymer solution. The impact of different process and formulation parameters including inlet angle, antisolvent and solvent flow rate(s), mixing time, drug concentration, polymer type and concentration was evaluated. Results and discussion: Stable dexibuprofen nanocrystals with a particle size of 45±3.0 nm and polydispersity index of 0.19±0.06 were obtained. Differential scanning calorimetry and powder X-ray diffraction confirmed the crystallinity. The key parameters observed were inlet angle 10°, antisolvent to solvent volume of 2.0/0.5 mL/min, 60 minutes mixing with 5 minutes sonication, Poloxamer-407 with a concentration of 0.5% w/v and drug concentration (5 mg/mm). The 60-day stability studies revealed that the nanocrystals were stable at 4°C and 25°C. The scanning electron microscopy and transmission electron microscopy images showed crystalline morphology with a homogeneous distribution. Conclusion: Stable dexibuprofen nanocrystals with retentive distinctive characteristics and having marked dissolution rate compared to raw and marketed formulations were efficiently fabricated. In future perspectives, these nanocrystals could be converted to solid dosage form and the process can be industrialized by chemical engineering approach
52

Fragmentation of molecular ions in ultrafast laser pulses

Ablikim, Utuq January 1900 (has links)
Master of Science / Department of Physics / Itzhak Ben-Itzhak / Imaging the interaction of molecular ion beams with ultrafast intense laser fields is a very powerful method to understand the fragmentation dynamics of molecules. Femtosecond laser pulses with different wavelengths and intensities are applied to dissociate and ionize molecular ions, and each resulting fragmentation channel can be studied separately by implementing a coincidence three-dimensional (3D) momentum imaging method. The work presented in this master’s report can be separated into two parts. First, the interaction between molecular ion beams and femtosecond laser pulses, in particular, the dissociation of CO[superscript]+ into C[superscript]++O, is studied. For that purpose, measurements are conducted at different laser intensities and wavelengths to investigate the possible pathways of dissociation into C[superscript]++O. The study reveals that CO[superscript]+ starts to dissociate from the quartet electronic state at low laser intensities. Higher laser intensity measurements, in which a larger number of photons can be absorbed by the molecule, show that the doublet electronic states with deeper potential wells, e.g. A [superscript]2Π, contribute to the dissociation of the molecule. In addition, the three-body fragmentation of CO[subscript]2[superscript]+ into C[superscript]++O[superscript]++O[superscript]+ is studied, and two breakup scenarios are separated using the angle between the sum and difference of the momentum vectors of two O[superscript]+ fragments. In the second part, improvements in experimental techniques are discussed. Development of a reflective telescope setup intended to increase the conversion efficiency of ultraviolet (UV) laser pulse generation is described, and the setup is used in the studies of CO[superscript]+ dissociation described in this report. The other technical study presented here is the measurement of the position dependence of timing signals picked off of a microchannel plate (MCP) surface. The experimental method is presented and significant time spread over the surface of the MCP detector is reported [1].
53

Development of microfluidic packages on multilayer organic substrate for cooling and tuning RF circuits

Lemtiri Chlieh, Outmane 07 January 2016 (has links)
The objective of this PhD research was to design and implement novel microfluidic radio-frequency (RF) structures on multilayer organic substrates for cooling and tuning purposes. The different designs were implemented to target applications up to C-band (4 GHz – 8 GHz) frequencies. The system-on-package (SoP) solution adopted throughout this work is well adapted for such designs where there is a need to integrate the functionality of different sub-components into a single hybrid fully packaged system. The first part of the thesis is dedicated to the study of a specific liquid cooling scheme using integrated microchannels on organics placed beneath different types of heat sources. A 1 W gallium nitride (GaN) die was cooled using this method and an analysis is presented regarding the cases where the coolant is static or dynamic inside the microchannel. The second part of the thesis deals with microfluidically reconfigurable microstrip RF circuits, mainly bandpass filters and power amplifiers (PAs). The microfluidic tuning technique is based on the change in the effective dielectric constant that the RF signal “sees” when traveling above two microchannels with different fluids. This technique was used to shift the frequency response of an L-band microstrip bandpass filter by replacing DI water with acetone inside a 60 mil micro-machined cavity. This technique was also used to design reconfigurable matching networks which constitute the main part of the proposed tunable GaN-based PA for S- and C-band applications. The final part of the thesis expands the previous results by combining both cooling and tuning in a single RF design. To prove the concept, cooling and tuning microchannels were integrated into a single package to cool a GaN-based PA and tune its frequency response at the same time from 2.4 GHz to 5.8 GHz and vice versa.
54

Embedded active and passive methods to reduce the junction temperature of power and RF electronics

Chen, Xiuping 22 May 2014 (has links)
AlGaN/GaN high electron mobility transistors (HEMTs) have been widely used for high power and high frequency RF communications due to their fast switching and large current handling capabilities. The reliability of such devices is strongly affected by the junction temperature where the highest magnitude occurs in a local region on the drain side edge of the gate called the hotspot. Thus, thermal management of these devices remains a major concern in the design and reliability of systems employing AlGaN/GaN HEMTs. Due to the large power densities induced in these devices locally near the drain side edge of the gate, it is clear that moving thermal management solutions closer to the heat generation region is critical in order to reduce the overall junction temperature of the device. In this work, we explore the use of embedded microchannel cooling in the substrate of AlGaN/GaN HEMTs made on Si and SiC substrates and compare them to passive cooling techniques using Si, SiC, and diamond substrates. In addition, the impact of cooling fluids and harsh environmental conditions were considered. The study was performed using a combination of CFD and finite volume analysis on packaged AlGaN/GaN HEMTs. Active cooling using embedded microchannels were shown to have a significant impact on the heat dissipation over the passive cooling methods, approaching or exceeding that of diamond cooled devices. For vertical power devices (IGBT), embedded microchannels in the power electronics substrates were explored. In both the power devices and lateral AlGaN/GaN HEMTs, the use of embedded microchannels with nonlinear channel geometries was shown to be the most effective in terms of reducing the device junction temperature while minimizing the pumping power required.
55

Microchannel Radiator: an Investigation of Microchannel Technology with Applications in Automotive Radiator Heat Exchangers

Checketts, Gus Thomas 08 1900 (has links)
Microchannels have been used in electronics cooling and in air conditioning applications as condensers. Little study has been made in the application of microchannels in automotive heat exchangers, particularly the radiator. The presented research captures the need for the design improvement of radiator heat exchangers in heavy-duty vehicles in order to reduce aerodynamic drag and improve fuel economy. A method for analyzing an existing radiator is set forth including the needed parameters for effective comparisons of alternative designs. An investigation of microchannels was presented and it was determined that microchannels can improve the overall heat transfer of a radiator but this alone will not decrease the dimensions of the radiator. Investigations into improving the air-side heat transfer were considered and an improved fin design was found which allows a reduction in frontal area while maintaining heat transfer. The overall heat transfer of the design was improved from the original design by 7% well as 52% decrease in frontal area but at the cost of 300% increase in auxiliary power. The energy saved by a reduction in frontal area is not substantial enough to justify the increase of auxiliary power. The findings were verified through a computational fluid dynamic model to demonstrate the heat transfer and pressure drop of microchannel tubes. The results confirmed that heat transfer of microchannels does improve the thermal performance of the radiator but the pressure drop is such that the net benefit does not outweigh the operating cost. An additional CFD study of the new fin geometry and air-side heat transfer predictions was conducted. The results of the study confirmed the theoretical calculations for the fin geometry.
56

Conception et caractérisation d'échangeurs-réacteurs à structuration multi-échelle / Design and characterization of exchanger-reactors with multi-scale structuring

Saber, Meryem 28 September 2009 (has links)
La présente thèse s’intéresse à la conception et la caractérisation des procédés microstructurés mettant en œuvre des réseaux de microcanaux de différentes dimensions. L’analyse de tels réseaux multi-échelles, représentatifs d’une parallélisastion de microsystèmes élémentaires, a essentiellement servi à identifier les principaux paramètres géométriques et physiques contrôlant les performances de ces réseaux complexes. On a cherché à quantifier l’influence des paramètres géométriques comme le rapport de résistances hydrodynamiques internes, le nombre de canaux et d’échelles opérant ainsi que leur répartition sur le réseau, sur des critères hydrodynamiques comme la maldistribution du fluide et la perte de charge résistive. Il est révélé qu’en fonction des contraintes imposées, un arrangement optimal des canaux sur un nombre pair d’échelles permet de réduire considérablement la maldistribution interne des flux et les pertes de charge résultantes. L’analyse thermique associée à l’analyse hydrodynamique a montré que les performances thermiques des réseaux sont fortement liées à leurs structurations géométriques internes. En présence de réactions catalytiques consécutives, ces mêmes réseaux enregistrent des déviations du rendement du produit désiré. Ces déviations peuvent être levées par une structuration appropriée du réseau catalytique multi-canal. La même architecture de ces réseaux peut être adaptée pour permettre le déroulement des opérations de mélange et/ou des réactions multi-phasiques. Ainsi, pour ces réseaux complexes, où un nombre élevé de variables imbriquées est considéré, des lignes directrices sont ressorties pour aider à leur conception et dimensionnement / This PhD thesis focuses on the design and the characterization of microstructured processes including microchannel networks of various dimensions. The analysis of such multi-scale networks, representative of elementary microsystems parallelization, is mainly used to identify the main geometrical and physical parameters controlling the network performances. Influence of geometrical parameters, such as the internal hydrodynamic resistances ratio, the number of channels and scales and their arrangement in the network, on hydrodynamic criteria like fluid maldistribution and pressure drop is investigated. It is shown that according to some specific constraints, an optimal arrangement of the channels on an even number of scales, allows to reduce significantly the internal flow maldistribution and the consequential pressure losses. The thermal analysis coupled with the hydrodynamic analysis illustrates that the thermal performances of microchannel networks are strongly affected by their internal geometrical arrangement. Nevertheless, the various mixture points located in the network compensate the fluid maldistribution resulting from a non appropriate geometrical arrangement. When consecutive catalytic reactions are performed inside these networks, deviations of the desired product rate can be recorded. These deviations can be reduced by an optimal catalytic network arrangement. The same architecture of these networks is also adapted to allow multi-phase mixing and /or reactions. Thus, using these complex networks, where several variables are considered, guidelines are derived in order to improve their design and their dimensionless
57

Transferência de calor e perda de pressão durante a ebulição convectiva de hidrocarbonetos em um dissipador de calor baseado em multi-microcanais / Heat transfer and pressure drop of hydrocarbon refrigerants during flow boiling in a microchannel array heat sink

Chávez Toro, Cristian Alfredo 08 September 2016 (has links)
A presente tese envolve um estudo experimental da ebulição convectiva no interior de um dissipador de calor baseado em multi-microcanais. Resultados experimentais para perda de pressão e coeficiente de transferência de calor foram levantados para os hidrocarbonetos R600a (isobutano), R290 (propano) e R1270 (propileno), fluidos com reduzido GWP (Global Warming Potential) e ODP (Ozone Depletion Potential) nulo. O desempenho termo-hidráulico destes fluidos foi avaliado em um dissipador de calor de cobre, contendo cinquenta canais paralelos com seção transversal retangular de 123x494 µm2 , 15 mm de comprimento e área de base de 15x15 mm2. Os experimentos foram realizados para fluxos de calor de até 400 kW/m2, velocidade mássica variando entre 165 e 823 kg/m2s, graus de sub-resfriamento do líquido na entrada da seção de testes de 5, 10 e 15°C e temperaturas de saturação de 21 e 25°C. Os dados experimentais foram amplamente analisados e discutidos, focando o efeito do fluido refrigerante. Oscilações dos sinais de temperatura e pressão foram analisadas parametricamente visando caracterizar efeitos de instabilidades térmicas. Adicionalmente, realizou-se análise comparativa de desempenho dos refrigerantes baseada na 2ª Lei da Termodinâmica. Os dados para hidrocarbonetos foram comparados com resultados de trabalhos prévios para o refrigerante R134a levantados na mesma seção de testes e utilizando a mesma bancada experimental. A partir destes dados, conclui-se que os hidrocarbonetos proporcionam coeficientes de transferência de calor superiores ao R134a. Em geral, o coeficiente de transferência de calor apresenta a seguinte ordem decrescente: R290, R1270, R600a e R134a. No entanto, o R290 necessitou superaquecimentos da parede superiores ao R1270 para iniciar o processo de ebulição. O refrigerante R1270 proporcionou perdas de pressão totais inferiores aos demais fluidos segundo a seguinte ordem decrescente: R600a, R134a, R290 e R1270. O refrigerante R1270 apresentou frequências de oscilação inferiores na temperatura da câmara de saída. Baseado na análise de desempenho da 2ª Lei da Termodinâmica, conclui-se que, as irreversibilidades devido ao processo de transferência de calor foram predominantes quando comparadas àquelas devido à perda de pressão. Através desta análise também constatou-se o melhor desempenho para o refrigerante R290. / The present thesis concerns an experimental study on flow boiling inside a microchannel array. Experimental results for two-phase pressure drop and heat transfer coefficient were acquired for the hydrocarbons R600a (isobutane), R290 (propane) and R1270 (propylene). These fluids present low Global Warming Potential (GWP) and null Ozone Depletion Potential (ODP). The cooling performance of these hydrocarbons were evaluated for a copper heat sink containing fifty parallel microchannels. The microchannels are rectangular with cross section of 123x494 µm2, 15 mm length and a footprint area of 15x15 mm2. The experimental evaluation was performed in a test facility located at the Laboratory of Thermal and Fluid Engineering of School of Engineering of São Carlos, University of Sao Paulo. The experiments were performed for heat fluxes up to 400 kW/m2, mass velocities from 165 to 823 kg/m2s, degrees of liquid subcooling at the test section inlet of 5, 10 and 15°C and saturation temperatures of 21 and 25°C. The experimental data were carefully analyzed and discussed focusing on the effects of the fluid on the heat sink thermal hydraulic performance. Fluctuations in the temperature and pressure were analyzed parametrically in order to evaluate thermal instability effects. Additionally, an exergy analysis was performed to evaluate the refrigerant efficiency during convective evaporation. Subsequently, the parametric effects and performance of hydrocarbons were compared with previous results for refrigerant R134a obtained in the same test facility and under the same experimental conditions. The refrigerant R290 provided heat transfer coefficients higher than R600a and R1270. However, R290 needed a degree of wall superheating for the onset of nucleate boiling higher than R1270. Based on the exergy analysis it was concluded that, the irreversibility associated to the heat transfer process are predominant compared with the irreversibility due to the pressure drop. According to the Second Law analyses it was also concluded R290 as the fluid providing the best performance.
58

Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere

Everett, E. Addison 01 May 2017 (has links)
In-situ composition measurements of the mesosphere/lower thermosphere (MLT) are challenging; this region is only accessible via high-speed sounding rockets, ambient pressures extend into the 10-3 Torr range, and particles of interest range in mass from electrons to meteoric smoke and dust particles. Time-of-flight mass spectrometers (TOF-MS) are capable of making fast, accurate measurements over a wide mass range. However, since they rely on pressure-sensitive microchannel plate (MCP) detectors and high voltages, they have rarely been applied at these altitudes. A new TOF-MS for making in-situ composition measurements in the MLT has been developed at the Space Dynamics Laboratory. This instrument employs modest acceleration potentials and a pressure-tolerant MCP detector. A Bradbury-Nielsen gate is used to produce short, well-defined ion pulses to reduce the temporal and spatial uncertainty of sampled ions. A prototype TOF-MS was constructed and used to demonstrate TOF-MS technology under conditions relevant to in-situ MLT measurements. Operational boundaries and capabilities of this new instrument were identified through laboratory experiments combined with computer modeling. The prototype instrument achieved a maximum resolution of 100 at m/z 40 (Ar), sufficient to resolve major atmospheric species of interest. During experiments at elevated pressures, the MCP detector maintained low background count rates (/second) at pressures as high as 10-3 Torr. A novel getter-based vacuum system was evaluated for use with the new TOF-MS, and a computer model was developed to simulate instrument pressure during a rocket flight. Results from these experiments suggest that when combined with an appropriately sized sampling aperture, this pumping system can extend the measurement range of the instrument to lower altitudes by 10 – 20 km, compared to an unpumped instrument. A computer model was developed to study the effects of critical operating parameters on instrument performance; the most important factor affecting resolution was found to be the initial energy spread of sampled ions. Sensitivity and number density measurement analyses suggest the new instrument will measure major species in the MLT at better than 10% uncertainty. Composition measurements made with the new TOF-MS will contribute to a better understanding of the MLT.
59

Analysis Of Single Phase Fluid Flow And Heat Transfer In Slip Flow Regime By Parallel Implementation Of Lattice Boltzmann Method On Gpus

Celik, Sitki Berat 01 September 2012 (has links) (PDF)
In this thesis work fluid flow and heat transfer in two-dimensional microchannels are studied numerically. A computer code based on Lattice Boltzmann Method (LBM) is developed for this purpose. The code is written using MATLAB and Jacket software and has the important feature of being able to run parallel on Graphics Processing Units (GPUs). The code is used to simulate flow and heat transfer inside micro and macro channels. Obtained velocity profiles and Nusselt numbers are compared with the Navier-Stokes based analytical and numerical results available in the literature and good matches are observed. Slip velocity and temperature jump boundary conditions are used for the micro channel simulations with Knudsen number values covering the slip flow regime. Speed of the parallel version of the developed code running on GPUs is compared with that of the serial one running on CPU and for large enough meshes more than 14 times speedup is observed.
60

Hybrid solid-state/fluidic cooling for thermal management of electronic components

Sahu, Vivek 31 August 2011 (has links)
A novel hybrid cooling scheme is proposed to remove non-uniform heat flux in real time from the microprocessor. It consists of a liquid cooled microchannel heat sink to remove the lower background heat flux and superlattice coolers to dissipate the high heat flux present at the hotspots. Superlattice coolers (SLC) are solid-state devices, which work on thermoelectric effect, and provide localized cooling for hotspots. SLCs offer some unique advantage over conventional cooling solutions. They are CMOS compatible and can be easily fabricated in any shape or size. They are more reliable as they don't contain any moving parts. They can remove high heat flux from localized regions and provide faster time response. Experimental devices are fabricated to characterize the steady-state, as well as transient performance, of the hybrid cooling scheme. Performance of the hybrid cooling scheme has been examined under various operating conditions. Effects of various geometric parameters have also been thoroughly studied. Heat flux in excess of 300 W/cm² has been successfully dissipated from localized hotspots. Maximum cooling at the hotspot is observed to be more than 6 K. Parasitic heat transfer to the superlattice cooler drastically affects its performance. Thermal resistance between ground electrode and heat sink, as well as thermal resistance between ground electrode and superlattice cooler, affect the parasitic heat transfer from to the superlattice cooler. Two different test devices are fabricated specifically to examine the effect of both thermal resistances. An electro-thermal model is developed to study the thermal coupling between two superlattice coolers. Thermal coupling significantly affects the performance of an array of superlattice coolers. Several operating parameters (activation current, location of ground electrode, choice of working fluid) affect thermal coupling between superlattice coolers, which has been computationally as well as experimentally studied. Transient response of the superlattice cooler has also been examined through experiments and computational modeling. Response time of the superlattice cooler has been reported to be less than 35 µs.

Page generated in 0.0491 seconds