• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • Tagged with
  • 30
  • 24
  • 17
  • 16
  • 14
  • 10
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Influência da delimitação da área adesiva no ensaio mecânico de microcisalhamento / Evaluation of adhesive area delimitation on microshear test

Angela Mayumi Shimaoka 26 June 2007 (has links)
Este estudo teve como objetivos avaliar se a delimitação da área adesiva a ser testada no ensaio mecânico de microcisalhamento é capaz de alterar os resultados de resistência de união obtidos; determinar se a delimitação da área adesiva do ensaio mecânico de microcisalhamento pode alterar o ranqueamento dos sistemas adesivos analisados e correlacionar os tipos de fratura encontrados com valores de resistência adesiva obtidos em cada um dos grupos experimentais. As unidades experimentais foram confeccionadas sobre 18 superfícies de dentina obtidas a partir de incisivos bovinos distribuídas aleatoriamente em 3 grupos, segundo o sistema adesivo a ser utilizado (Adper Single Bond 2, Clearfil Se Bond, Clearfil S3 Bond). Desta forma foram compostos 6 grupos experimentais segundo os dois fatores de variação a serem estudados: sistema adesivo e delimitação da área adesiva. Sobre cada superfície dentinária foram confeccionados 4 cilindros em resina composta, sendo 2 com delimitação da área adesiva e 2 sem a delimitação desta área, totalizando n=12. Após 24 horas de armazenamento os espécimes foram submetidos ao ensaio mecânico de microcisalhamento. O teste estatístico ANOVA (p<0,01) e o teste auxiliar de Tukey determinaram que todos os grupos experimentais em que a delimitação da área adesiva foi realizada apresentaram menores valores de resistência adesiva quando comparados aos seus respectivos grupos controle (sem delimitação da área adesiva). Para os grupos em que não foi realizada a delimitação da área não foram observadas diferenças estatisticamente significantes entre os adesivos empregados. Em contrapartida, quando não foi realizada a delimitação, o sistema adesivo Clearfil S3 Bond mostrou maiores valores de resistência adesiva quando comparado aos sistemas Adper Single Bond 2 e Clearfil SE Bond, que por sua vez não se mostraram estatisticamente diferentes entre si. Concluiu-se que a delimitação da área adesiva no ensaio de microcisalhamento alterou os resultados de resistência adesiva obtidos, e que a modificação da metodologia do ensaio mecânico de microcisalhamento foi capaz de alterar o ranqueamento dos sistemas adesivos analisados. / This study had as objectives to evaluate if the delimitation of adhesive area on microshear test is capable to modify the values of shear bond strength; to determine if this delimitation can modify the ranking of the analyzed adhesive systems and to correlate the found types of failure with the values of bond strength in each experimental group. The specimens were confectioned on 18 incisors bovine dentine surfaces randomly distributed into 3 groups, according to adhesive system used (Adper Single Bond 2, Clearfil If Bond, Clearfil S3 Bond). In such a way, 6 experimental groups were designed according to two factors of variation to be studied: adhesive system and delimitation of the adhesive area. Over each dentin surface were confectioned 4 composite resin cylinders, being 2 with delimitation of the adhesive area and 2 without the delimitation of this area, totalizing n=12. After 24 hours of storage the specimens were submitted to microshear test Statistical test ANOVA (p<0,01) and Tukey?s test determined that all the experimental groups where the delimitation of the adhesive area was carried through presented lesser values of shear bond strength when compared with its respective control groups (without delimitation of adhesive area). Groups without area delimitation did not been demonstrate statistical significant differences between adhesives. On the other hand, when such delimitation was not carried through, the adhesive system Clearfil S3 Bond demonstrates greater values of shear bond strength compared to Adper Single 2 Bond and Clearfil SE Bond, which did not showed statistical difference between them. It was concluded that the delimitation of the adhesive area in the microshear test altered the obtained results of adhesive resistance, and that the modification of microshear test methodology was capable to modify the ranking of the analyzed adhesive systems.
12

Resistência de união de diferentes zircônias envelhecidas / Bonding strength of different aged zirconia

Gallina, Bernardo Luiz 02 March 2017 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-05-28T19:18:23Z No. of bitstreams: 2 Bernardo Luiz Gallina.pdf: 1455679 bytes, checksum: 0664c2eccf6aef896ff0831448f3e489 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-28T19:18:23Z (GMT). No. of bitstreams: 2 Bernardo Luiz Gallina.pdf: 1455679 bytes, checksum: 0664c2eccf6aef896ff0831448f3e489 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-02 / Zirconia has been extensively researched due to its biocompatibility, mechanical resistance and having an aesthetic property, being widely used in dentistry. Prettau Anterior zirconia presents superior esthetics for anterior region, when compared to other zirconia. The objective of this study was to evaluate the bond strength of two Zirconias with different compositions.For this purpose, twenty-two (22) blocks were made and cut with 3x5x10mm of each of the evaluated materials: Zirconia ICE Zirkon Translucent (ZT) and ZirconiaPrettau Anterior (ZPA). The specimens were made using resin cement RelyX Unicem U200 with a vinylpolysiloxane matrix assistence. Then, 11 blocks of each group were separated in two storage times: 1 and 90 days of storage in distilled water at 37 ° C, totaling n = 11. The Micro-shearing test was performed at a speed of 0.5 mm / min on the Universal testing machine. The samples were also submitted to fracture analysis and analysis by scanning electron microscopy. The results were submitted to the Shapiro Wilk test, Analysis of Variance ANOVA (two-way) and then to Tukey's test, p <0.01. The means obtained for the group aged in 1 day were: 7.56 (+1.02) for ZT, 9.38 (+1.22) for ZPA. And for the samples that aged 90 days were: 0.47 (+1.02) for ZT, 1.74 (+0.58) for ZPA. Statistically significant differences were observed for the factors: ceramic type and aging time. According to the obtained results, it was possible to observe that Zirconia Prettau Anterior showed results statistically superior to Zirconia ICE Zirkon Translucent, in both aging times evaluated. / A zircônia vem sendo pesquisada de maneira exaustiva devido a sua biocompatibilidade, resistência mecânica e por sua estética. A zircônia Prettau Anterior apresenta estética superior para região anterior, quando comparada a outras zircônias. O objetivo desse trabalho foi avaliar comparativamente a resistência de união de duas Zircônias com composições diferentes. Para isso, foram confeccionados vinte e dois (22) blocos foram cortados com 3x5x10mm de cada um dos materiais avaliados: Zircônia ICE Zirkon Translucent (ZT) e Zircônia Prettau Anterior(ZPA). Os corpos de prova foram confeccionados usando cimento resinoso RelyX Unicem U200 com auxílio de uma matriz de silicone por adição Express. Onze blocos de cada grupo foram destinados para cada um dos tempos de armazenamento (24 horas e 90 dias) em água destilada a 37oC. O teste de microcisalhamento foi realizado a uma velocidade de 0.5mm/min em máquina de ensaio Universal EMIC DL-200 MF. As amostras foram submetidas também à análise de fratura e análise em microscopia eletrônica de varredura. Os resultados obtidos foram submetidos ao teste Shapiro Wilk, Análise de Variância ANOVA (two-way) e, em seguida, ao teste de Tukey, p < 0,01. As médias obtidas para o grupo envelhecido em 1 dia foram: 7,56(+1,02) MPa para ZT, 9,38(+1,22) MPa para ZPA, e para as amostras envelhecidas por 90 dias foram: 0,47(+1,02) MPa para ZT, 1,74(+0,58) MPa para ZPA. Foram observadas diferenças estatisticamente significantes para os fatores tipo de cerâmica e tempo de envelhecimento. De acordo com os resultados obtidos foi possível observar que a Zircônia Prettau Anterior mostrou resultados estatisticamente superiores a Zircônia ICE Zirkon Translucent, nos dois tempos de envelhecimento avaliados.
13

Avaliação do efeito de diferentes lasers de alta intensidade no tratamento de superfície da cerâmica Y-TZP pré e pós sinterização / Effect evaluation of different high-intensity lasers on the surface treatment of Y-TZP ceramic before and after sintering

Silva, Amanda Verna e 12 September 2011 (has links)
O objetivo deste estudo foi avaliar os efeitos dos lasers de Nd:YAG, CO2 e Er,Cr:YSGG no tratamento de superfície da cerâmica Y-TZP antes e depois da sinterização final, por meio de Microscopia Eletrônica de Varredura (MEV), mensuração da rugosidade de superfície (Ra) e teste de resistência adesiva por microcisalhamento (RAD). Para tanto, barras de Y-TZP foram confeccionadas e distribuídas entre as 3 fases do experimento, sendo as duas primeiras fases seletivas para a identificação dos parâmetros lasers a serem utilizados na fase 3 de análise da RAD. Na fase 1 MEV - foram testados parâmetros que variavam entre 50 e 100 mJ para o laser de Nd:YAG, 2 a 4W para o laser de CO2 e 1 a 3,5W para o laser de Er,Cr:YSGG, testados antes ou após a sinterização da Y-TZP. Observou-se que a maioria dos tratamentos foram capazes de promover alterações na cerâmica com diferentes intensidades dependendo do parâmetro utilizado. Para a fase 2 Ra foram selecionados apenas os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG aplicados antes da sinterização da cerâmica, sendo que cada laser foi avaliado individualmente e comparados ao tratamento de superfície com o sistema Rocatec. Os tratamentos com os maiores valores de Ra foram: para o laser de Nd:YAG - 1,6W-20Hz (11.623±3,419) e para o laser de Er,Cr:YSGG - 3W (6,051±1,991). O sistema Rocatec apresentou os menores valores de rugosidade (1,297±0,026). Para a fase 3 do estudo RAD foram selecionados os parâmetros que apresentaram os maiores valores de Ra para cada laser, além do parâmetro com características favoráveis à adesão observado na fase 1 MEV. Sendo assim, o teste de microcisalhamento foi realizado entre a cerâmica Y-TZP tratada com os lasers antes da sinterização final, nos parâmetros de 1,6W e 1,2W para o laser de Nd:YAG e 3W para o laser de Er,Cr:YSGG; e com o sistema Rocatec, utilizando-se dois cimentos resinosos de dupla ativação (Panavia e RelyX U100). A análise estatística ANOVA Split-Plot dos dados de RAD obtidos revelou que não houve diferença estatística entre os cimentos estudados. Porém, no fator tratamentos de superfície observou-se que os maiores valores de RAD foram obtidos para o sistema Rocatec (20,92±3,4MPa). Os dois parâmetros utilizados para o laser de Nd:YAG foram semelhantes entre si com valores de RAD intermediários (1,2W=9,79±4 MPa e 1,6W=11,35±3,64 MPa) e o tratamento com o laser de Er,Cr:YSGG apresentou os menores valores de RAD (1,43±1,21MPa). Pôde-se concluir que os tratamentos de superfície com todos os lasers testados nos parâmetros de irradiação após a sinterização, provocaram danos à cerâmica Y-TZP. Os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG antes da sinterização, apesar de apresentarem características micromorfológicas sugestivas de aumento da área de superfície, não foram suficientes para aumentar a resistência adesiva entre a Y-TZP e os cimentos resinosos testados. / The aim of this study was to evaluate the effects of Nd:YAG, CO2 and Er,Cr:YSGG lasers on the surface treatment of Y-TZP ceramic before and after the final sintering by means of Scanning Electron Microscope (SEM), surface roughness measurement (Ra) and microshear bond strength adhesive resistance test (RAD). In order to do so, Y-TZP bars were produced and distributed among the three experimental phases, being the two first ones selective in what regards identifying parameters for the lasers used in phase 3 of the RAD analysis. In phase 1 SEM parameters varying from 50 to 100 mJ were tested for the Nd:YAG laser, from 2 to 4W for the CO2 laser and from 1 to 3,5W for the Er,Cr:YSGG laser, either before or after the Y-TZP sintering. It was observed that most treatments were able to promote changes in the ceramic with varied intensity according to the parameter used. In phase 2 Ra only treatments with Nd:YAG and Er,Cr:YSGG lasers applied before ceramic sintering were selected, and each laser was individually evaluated and compared to the surface treatment with Rocatec system. The treatments which had the highest Ra values were: 1,6W-20Hz (11.623±3,419) for the Nd:YAG laser and 3W (6,051±1,991) for Er,Cr:YSGG. Rocatec system showed the lowest roughness levels (1,297±0,026). As for phase 3 of the study RAD the highest Ra parameters for each laser were selected as well as the parameter with favorable characteristics to adherence observed in phase 1 SEM. Therefore, the microshear bond strength test was done not only in the Y-TZP ceramic treated with lasers before the final sintering (using 1,6W and 1,2W parameters for the Nd:YAG laser and 3W for Er,Cr:YSGG), but also in the Rocatec system, making use of two double activation resin cements (Panavia e RelyX U100). The ANOVA Split-Plot statistical analysis of the RAD data showed that there were no statistical variations concerning the studied cements. However, in what regards the surface treatments, it was observed that the highest RAD values were obtained for the Rocatec system (20,92±3,4MPa). Both parameters used for the Nd:YAG laser were similar, presenting intermediate RAD values (1,2W=9,79±4 and 1,6W=11,35±3,64 MPa). The treatment which used Er,Cr:YSGG laser presented the lowest RAD values (1,43±1,21MPa). It was possible to conclude that surface treatments with all tested lasers in the irradiation parameters after sintering caused damage to the Y-TZP ceramic. Treatments making use of Nd:YAG and Er,Cr:YSGG lasers before the sintering were not enough in order to increase the adhesive resistance between Y-TZP and the resin cements tested, even though they presented micromorphological characteristics that indicated growth in the surface area.
14

Avaliação do efeito de diferentes lasers de alta intensidade no tratamento de superfície da cerâmica Y-TZP pré e pós sinterização / Effect evaluation of different high-intensity lasers on the surface treatment of Y-TZP ceramic before and after sintering

Amanda Verna e Silva 12 September 2011 (has links)
O objetivo deste estudo foi avaliar os efeitos dos lasers de Nd:YAG, CO2 e Er,Cr:YSGG no tratamento de superfície da cerâmica Y-TZP antes e depois da sinterização final, por meio de Microscopia Eletrônica de Varredura (MEV), mensuração da rugosidade de superfície (Ra) e teste de resistência adesiva por microcisalhamento (RAD). Para tanto, barras de Y-TZP foram confeccionadas e distribuídas entre as 3 fases do experimento, sendo as duas primeiras fases seletivas para a identificação dos parâmetros lasers a serem utilizados na fase 3 de análise da RAD. Na fase 1 MEV - foram testados parâmetros que variavam entre 50 e 100 mJ para o laser de Nd:YAG, 2 a 4W para o laser de CO2 e 1 a 3,5W para o laser de Er,Cr:YSGG, testados antes ou após a sinterização da Y-TZP. Observou-se que a maioria dos tratamentos foram capazes de promover alterações na cerâmica com diferentes intensidades dependendo do parâmetro utilizado. Para a fase 2 Ra foram selecionados apenas os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG aplicados antes da sinterização da cerâmica, sendo que cada laser foi avaliado individualmente e comparados ao tratamento de superfície com o sistema Rocatec. Os tratamentos com os maiores valores de Ra foram: para o laser de Nd:YAG - 1,6W-20Hz (11.623±3,419) e para o laser de Er,Cr:YSGG - 3W (6,051±1,991). O sistema Rocatec apresentou os menores valores de rugosidade (1,297±0,026). Para a fase 3 do estudo RAD foram selecionados os parâmetros que apresentaram os maiores valores de Ra para cada laser, além do parâmetro com características favoráveis à adesão observado na fase 1 MEV. Sendo assim, o teste de microcisalhamento foi realizado entre a cerâmica Y-TZP tratada com os lasers antes da sinterização final, nos parâmetros de 1,6W e 1,2W para o laser de Nd:YAG e 3W para o laser de Er,Cr:YSGG; e com o sistema Rocatec, utilizando-se dois cimentos resinosos de dupla ativação (Panavia e RelyX U100). A análise estatística ANOVA Split-Plot dos dados de RAD obtidos revelou que não houve diferença estatística entre os cimentos estudados. Porém, no fator tratamentos de superfície observou-se que os maiores valores de RAD foram obtidos para o sistema Rocatec (20,92±3,4MPa). Os dois parâmetros utilizados para o laser de Nd:YAG foram semelhantes entre si com valores de RAD intermediários (1,2W=9,79±4 MPa e 1,6W=11,35±3,64 MPa) e o tratamento com o laser de Er,Cr:YSGG apresentou os menores valores de RAD (1,43±1,21MPa). Pôde-se concluir que os tratamentos de superfície com todos os lasers testados nos parâmetros de irradiação após a sinterização, provocaram danos à cerâmica Y-TZP. Os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG antes da sinterização, apesar de apresentarem características micromorfológicas sugestivas de aumento da área de superfície, não foram suficientes para aumentar a resistência adesiva entre a Y-TZP e os cimentos resinosos testados. / The aim of this study was to evaluate the effects of Nd:YAG, CO2 and Er,Cr:YSGG lasers on the surface treatment of Y-TZP ceramic before and after the final sintering by means of Scanning Electron Microscope (SEM), surface roughness measurement (Ra) and microshear bond strength adhesive resistance test (RAD). In order to do so, Y-TZP bars were produced and distributed among the three experimental phases, being the two first ones selective in what regards identifying parameters for the lasers used in phase 3 of the RAD analysis. In phase 1 SEM parameters varying from 50 to 100 mJ were tested for the Nd:YAG laser, from 2 to 4W for the CO2 laser and from 1 to 3,5W for the Er,Cr:YSGG laser, either before or after the Y-TZP sintering. It was observed that most treatments were able to promote changes in the ceramic with varied intensity according to the parameter used. In phase 2 Ra only treatments with Nd:YAG and Er,Cr:YSGG lasers applied before ceramic sintering were selected, and each laser was individually evaluated and compared to the surface treatment with Rocatec system. The treatments which had the highest Ra values were: 1,6W-20Hz (11.623±3,419) for the Nd:YAG laser and 3W (6,051±1,991) for Er,Cr:YSGG. Rocatec system showed the lowest roughness levels (1,297±0,026). As for phase 3 of the study RAD the highest Ra parameters for each laser were selected as well as the parameter with favorable characteristics to adherence observed in phase 1 SEM. Therefore, the microshear bond strength test was done not only in the Y-TZP ceramic treated with lasers before the final sintering (using 1,6W and 1,2W parameters for the Nd:YAG laser and 3W for Er,Cr:YSGG), but also in the Rocatec system, making use of two double activation resin cements (Panavia e RelyX U100). The ANOVA Split-Plot statistical analysis of the RAD data showed that there were no statistical variations concerning the studied cements. However, in what regards the surface treatments, it was observed that the highest RAD values were obtained for the Rocatec system (20,92±3,4MPa). Both parameters used for the Nd:YAG laser were similar, presenting intermediate RAD values (1,2W=9,79±4 and 1,6W=11,35±3,64 MPa). The treatment which used Er,Cr:YSGG laser presented the lowest RAD values (1,43±1,21MPa). It was possible to conclude that surface treatments with all tested lasers in the irradiation parameters after sintering caused damage to the Y-TZP ceramic. Treatments making use of Nd:YAG and Er,Cr:YSGG lasers before the sintering were not enough in order to increase the adhesive resistance between Y-TZP and the resin cements tested, even though they presented micromorphological characteristics that indicated growth in the surface area.
15

Influência da densidade tubular em diferentes profundidades dentinárias na estabilidade de união de cimentos de iônomero de vidro / Influence of tubular density in diferent dentin depths in bonding stability of glass ionomer cements

Silva, Aline Galvão dos Santos 19 February 2016 (has links)
O objetivo do estudo foi avaliar a influência da densidade tubular em diferentes profundidades dentinárias na estabilidade de união de dois cimentos de ionômero de vidro (CIV) de alta viscosidade. Vinte terceiros molares foram alocados em 6 grupos experimentais, de acordo com a profundidade da dentina - proximal, oclusal superficial ou oclusal profunda, e os CIVs - Fuji IX (GC Corp.) e Ketac(TM) Molar Easy Mix (3M/ESPE). Inicialmente os dentes foram cortados a fim de se obter fatias de aproximadamente 1 mm de espessura de dentina proximal, oclusal superficial e profunda. Em seguida, foi realizado uma análise topográfica das secções das diferentes superfícies e profundidades em microscopia confocal a laser (100X) para obtenção das médias da densidade tubular em cada profundidade. Cânulas de polietileno foram então posicionadas sobre as secções de dentina pré-tratadas e preenchidas pelos CIVs. Os espécimes foram armazenados em água destilada por 24 h e 12 meses a 37°C, em seguida foram submetidos ao ensaio de microcisalhamento (0,5 mm/min). Após o ensaio, foi realizada a análise do padrão de fratura em estereomicroscópio (400X). Os dados obtidos foram submetidos à Análise de Variância para dados repetidos, seguido do teste de Tukey (?=5%). Verificamos que a densidade dos túbulos dentinários, em diferentes profundidades de molares permanentes, é inversamente proporcional a resistência de união de cimentos de ionômero de vidro de alta viscosidade. Foi ainda observado em todos os grupos que a resistência de união após 24 horas é maior do que em 12 meses, indicando degradação da interface adesiva ao longo do tempo. / The aim of this study was to evaluate the influence of dentin tubule density of different depths in the bond stability of two high viscous glass ionomer cements (GIC). Twenty (third) molars were assigned into 6 experimental groups, according to the depth of dentin - proximal, superficial or deep occlusal occlusal and the GICs - Fuji IX (GC Corp.) and Ketac (TM) Molar Easy Mix (3M / ESPE). Initially, the teeth were cut to obtain slices approximately 1 mm thick for approximal, superficial and deep occlusal surfaces. Then it was performed a topographical analysis of sections of different depths surfaces and laser confocal microscopy (100X) to obtain averages of the tubular density at each depth. Polyethylene cannulae were then positioned on the pre-treated dentin sections and filled with GIC. The specimens were stored in distilled water for 24 h and 12 months at 37°C were then subjected to microshear bonding test (0.5 mm / min). After the test, a fracture analysis pattern was performed in stereomicroscope (400X). The data were submitted to ANOVA for repeated measures followed by the Tukey test (? = 5%). We found that the density of dentinal tubules at different depths of permanent molars, is inversely proportional to the bond strength of high viscosity glass ionomer cements. It was observed in all groups which bond strength after 24 hours is higher than in 12 months, indicating degradation of the interface over time.
16

Influência da densidade tubular em diferentes profundidades dentinárias na estabilidade de união de cimentos de iônomero de vidro / Influence of tubular density in diferent dentin depths in bonding stability of glass ionomer cements

Aline Galvão dos Santos Silva 19 February 2016 (has links)
O objetivo do estudo foi avaliar a influência da densidade tubular em diferentes profundidades dentinárias na estabilidade de união de dois cimentos de ionômero de vidro (CIV) de alta viscosidade. Vinte terceiros molares foram alocados em 6 grupos experimentais, de acordo com a profundidade da dentina - proximal, oclusal superficial ou oclusal profunda, e os CIVs - Fuji IX (GC Corp.) e Ketac(TM) Molar Easy Mix (3M/ESPE). Inicialmente os dentes foram cortados a fim de se obter fatias de aproximadamente 1 mm de espessura de dentina proximal, oclusal superficial e profunda. Em seguida, foi realizado uma análise topográfica das secções das diferentes superfícies e profundidades em microscopia confocal a laser (100X) para obtenção das médias da densidade tubular em cada profundidade. Cânulas de polietileno foram então posicionadas sobre as secções de dentina pré-tratadas e preenchidas pelos CIVs. Os espécimes foram armazenados em água destilada por 24 h e 12 meses a 37°C, em seguida foram submetidos ao ensaio de microcisalhamento (0,5 mm/min). Após o ensaio, foi realizada a análise do padrão de fratura em estereomicroscópio (400X). Os dados obtidos foram submetidos à Análise de Variância para dados repetidos, seguido do teste de Tukey (?=5%). Verificamos que a densidade dos túbulos dentinários, em diferentes profundidades de molares permanentes, é inversamente proporcional a resistência de união de cimentos de ionômero de vidro de alta viscosidade. Foi ainda observado em todos os grupos que a resistência de união após 24 horas é maior do que em 12 meses, indicando degradação da interface adesiva ao longo do tempo. / The aim of this study was to evaluate the influence of dentin tubule density of different depths in the bond stability of two high viscous glass ionomer cements (GIC). Twenty (third) molars were assigned into 6 experimental groups, according to the depth of dentin - proximal, superficial or deep occlusal occlusal and the GICs - Fuji IX (GC Corp.) and Ketac (TM) Molar Easy Mix (3M / ESPE). Initially, the teeth were cut to obtain slices approximately 1 mm thick for approximal, superficial and deep occlusal surfaces. Then it was performed a topographical analysis of sections of different depths surfaces and laser confocal microscopy (100X) to obtain averages of the tubular density at each depth. Polyethylene cannulae were then positioned on the pre-treated dentin sections and filled with GIC. The specimens were stored in distilled water for 24 h and 12 months at 37°C were then subjected to microshear bonding test (0.5 mm / min). After the test, a fracture analysis pattern was performed in stereomicroscope (400X). The data were submitted to ANOVA for repeated measures followed by the Tukey test (? = 5%). We found that the density of dentinal tubules at different depths of permanent molars, is inversely proportional to the bond strength of high viscosity glass ionomer cements. It was observed in all groups which bond strength after 24 hours is higher than in 12 months, indicating degradation of the interface over time.
17

EFEITO DO CLAREAMENTO DENTAL NA RESISTÊNCIA DE UNIÃO DE SISTEMAS ADESIVOS AO ESMALTE / THE EFFECT OF THE TOOTH WHITENING IN BOND STRENGTH OF ADHESIVE SYSTEMS TO ENAMEL.

Steglich, Ana Guerreiro 24 July 2014 (has links)
With the increasing demand of the population for dental bleaching and concomitant evolution of adhesive systems, has increasingly sought to know more about the relationship between bleaching and esthetic restorations. Because of that this work aims to evaluate the influence of in-office bleaching challenge the bond strength of adhesive systems to dental enamel. To this were randomly divided 40 permanent human molars were divided into 4 groups (n = 10) teeth in accordance with the Single Bond (3M ESPE) and Universal Single Bond (3M ESPE) and treatment (bleaching and whitening without). The teeth were prepared and had their root surface removed in the transverse direction with diamond disk, the coronal portion was sectioned along the axis of the tooth in the mesial - distal direction, resulting in two sections, which were embedded in acrylic resin in PVC rings, the eixar mode exposed enamel surface. The smooth surfaces were ground with 600-grit sandpaper under water cooling, so you obtain a flat surface. On the surface enamel adhesive system according to the group indicated and in accordance with the manufacturers recommendations was applied and after that the adhesive was light cured for 10 seconds. After light curing of the adhesive was a cylinder made of composite resin, with dimensions of 2.0 x1, 09mm, with the aid of an all perforated starch. The specimens of groups with whitening underwent 2 sessions of office bleaching with carbamide peroxide gel 37 % with an interval of 7 days between them. After that were stored in a thermal oven at 37 º C for 24h and then the mechanical test microshear was performed to measure the bond strength. Have the groups without bleaching were stored in a thermal oven 37 º C for 24h and then subjected to testing microshear. The data relating to test microshear, expressed in MPa, were subjected to statistical analysis. The sampling distribution of the data was assumed to follow normal after completion of the Kolmogorov - Smirnov test. The values of bond strength in MPa were subjected to analysis of variance of two factors in order to check the influence of the bleaching procedure after challenge adhesive and adhesive system. The significance level for all analyzes was 5% and these were performed in Minitab 17 software (Minitab Inc., State College, PA, USA). Analysis of variance was not able to point to significant differences factors prior treatment with acid or with self-etching adhesive conditioning. As for tooth whitening there were no significant differences (p = 0.272) .Also there were no significant differences in the adhesive system employed , SBU or BSA (p = 0.187) nor for the interaction between the two factors (p = 0.758 ) . So the thooth whitening is a safe procedure in this conditions. / Com o aumento da procura da população pelo clareamento dental e concomitantemente com a evolução dos sistemas adesivos, cada vez tem se buscado mais saber sobre a relação entre o clareamento e as restaurações estéticas. Frente a isso esse trabalho tem o objetivo de avaliar a influência clareamento dental de consultório na resistência de união de sistemas adesivos ao esmalte dentário. Para isso foram divididos aleatoriamente 40 dentes molares humanos permanentes que foram distribuídos em 4 grupos (n=10), de acordo com o sistema adesivo Single Bond (3M ESPE) e Single Bond Universal (3M ESPE) e tratamento (com clareamento e sem clareamento). Os dentes foram preparados e tiveram sua superfície radicular removida no sentido transversal com disco diamantado, a porção coronária foi seccionada ao longo eixo do dente no sentido mésio-distal, resultando em duas secções, que foram embutidas em resina acrílica em anéis de PVC, a modo de deixar exposta a superfície do esmalte. As faces lisas foram abrasionadas com lixa d água de granulação 600 sob refrigeração, para que se obtivesse uma superfície plana. Sobre a superfície de esmalte foi aplicado o sistema adesivo de acordo com o grupo indicado e com as recomendações dos fabricantes e após isso o adesivo foi fotopolimerizado por 10 segundos. Após a fotopolimerização do adesivo foi confeccionado um cilindro de resina composta, com dimensões de 2,0 x 1,09 mm, com o auxílio de um tubo de amido perfurado. Os espécimes dos grupos com clareamento foram submetidos a duas sessões de clareamento de consultório com gel de peróxido de carbamida 37% com intervalo de 7 dias entre elas. Após isso foram armazenados em estufa térmica a 37º C por 24 h e então foi realizado o ensaio mecânico de microcisalhamento para mensurar a resistência de união. Já os grupos sem clareamento foram armazenados em estufa térmica 37º C por 24 h e depois submetidos a ensaio de microcisalhamento. Os dados referentes ao ensaio de microcisalhamento, expressos em MPa, foram submetidos a análise estatística. A distribuição amostral dos dados foi assumida como seguindo a normal, após a realização do teste de Kolmogorov Smirnov. Os valores de resistência de união em MPa foram submetidos a análise de variância de dois fatores a fim de verificar a influência do desafio clareador após procedimento adesivo e sistema adesivo. O nível de significância considerado em todas as análises foi de 5% e essas foram realizadas no programa Minitab 17 (Minitab Inc., State College, PA, EUA). A análise de variância não foi capaz de apontar diferenças significativas para os fatores tratamento com condicionamento ácido prévio ou com adesivo autocondicionante. Quanto ao clareamento dental não houve diferenças significativas (p=0,272). Também não houve diferenças significativas quanto ao sistema adesivo empregado, SBU ou ASB (p=0,187), nem para a interação entre os dois fatores (p=0,758). Sendo assim o clareamento dental um procedimento seguro nas condições abordadas.
18

Efeito de três diferentes doses de radiação com raios-X na microdureza, morfologia superficial, espectrometria de energia dispersiva de radios-X (EDS) e resistência de união ao esmalte e dentina com dois diferentes sistemas adesivos / The effect of three different doses of radiation with x-rays in the microhardness, superficial morfology, energy dispersive X-ray spectroscopy (EDS) and bond strength of enamel and dentin with two adhesive systems

Cunha, Sandra Ribeiro de Barros da 19 January 2015 (has links)
Este estudo teve como objetivo analisar dentina e esmalte irradiados com diferentes doses de radiação ionizante com raios-x (20, 40 e 70Gy), através da microdureza, morfologia superficial, conteúdo mineral e resistência de união com adesivo de condicionamento total de 2 etapas (Adper Single Bond 2) e um novo sistema adesivo, universal, com a técnica auto-condicionante (Universal Single Bond). Oitenta e quatro terceiros molares humanos foram cortados, separados e preparados para cada ensaio. Para os ensaios de microdureza e microcisalhamento as amostras foram incluídas em resina acrílica e polidas. Para a microscopia eletrônica de varredura (MEV) e espectrometria de energia dispersiva de raios-x (EDS), as amostras foram fixadas em solução de glutaraldeído 3%, lavadas em solução de cacodilato 0,1M e desidratadas em álcool etílico crescente. A microdureza (n=30) foi realizada pré e pós-radioterapia, com força de 50gf em esmalte cervical, médio e oclusal e 25gf em dentina profunda, média e rasa, por 30s. As amostras para o microcisalhamento foram divididas em 4 grupos (n=20) e 2 subgrupos (n=10) conforme o sistema adesivo. Foram construídos 3 corpos de prova cilíndricos com 1mm de diâmetro e altura em cada amostra. O teste de microcisalhamento foi realizado em máquina de ensaio universal com velocidade de 1mm/min. Os resultados indicam perda de propriedade de microdureza apenas em esmalte cervical em todas as três doses (20Gy pré-radioterapia: 298,04±11,80 e pós-radioterapia: 294,36±16,68; 40Gy pré-radioterapia: 285±19,45 e pósradioterapia: 275,3±36; 70Gy pré-radioterapia: 291,98±16,51 e pós-radioterapia: 283,68 ± 21,64) e em dentina em todas as profundidades (profunda: 20Gy préradioterapia: 57,79±1,96; pós-radioterapia: 55,37±1,30; 40Gy pré-radioterapia: 57,31±1,76; pós-radioterapia: 55,83±1,63; 70Gy não apresentou alterações; média: 20Gy pré-radioterapia: 58,05±1,79; pós-radioterapia: 55,36±1,20; 40Gy préradioterapia: 57,87± 2,04; pós-radioterapia: 55,65 ± 2,48; 70Gy não apresentou alterações; rasa: 20Gy pré-radioterapia: 56,60±12,17; pós-radioterapia: 55,18±2,57; 40Gy pré-radioterapia: 57,36±2,78; pós-radioterapia: 55,18± 2,57; 70Gy préradioterapia: 55,08±1,94; pós-radioterapia: 54,72±2,57). O teste de microcisalhamento não apresentou diferença significativa entre grupo controle e as 3 doses, tanto para esmalte (p=0,325) como para dentina (p=0,719), apresentando o adesivo Universal Single Bond, em dentina, a resistência de união mais satisfatória. A análise de padrão de fratura para dentina, indicou um maior número de rupturas coesivas em dentina na dose 70Gy quando comparada ao grupo controle. Em esmalte prevaleceram as fraturas do tipo adesivas. As eletromicrografias apresentaram alterações apenas em esmalte na dose 70Gy, com prismas de esmalte mais curtos e arredondados. O EDS mostrou que o conteúdo mineral permaneceu intacto em ambos substratos. Dentro das limitações de um estudo in vitro, conclui-se que a radiação ionizante apresenta maior interação preferencialmente em dentina, no entanto, o EDS mostra não haver modificação no conteúdo mineral em ambos substratos. Existe uma diminuição da microdureza em dentina, porém as alterações não são suficientes para interferir na resistência de união dos substratos irradiados, que mostraram resultados mais satisfatórios com o sistemas adesivos universal, utilizando-se a técnica auto-condicionante. / The aim of this study was to evaluate the effects of different doses (20Gy, 40Gy and 70Gy) of ionizing radiation with x-rays in the microhardness, superficial morphology, mineral content and bonding effectiveness with a 2 steps all-etch adhesive (Adper Single Bond 2) and the new generation of adhesive, the universal adhesive system, (Universal Single Bond), using the self-etch technique. Eighty-four third molars were cutted, separed and prepared for each assay. For the microshear-bond and microhardness the samples were included in acrylic resin and then polished. For the scanning electron miscroscopy (SEM) and energy dispersive x-ray spectroscopy (EDS), the samples were fixated in a 3% glutaraldehyde solution, washed in 0,1M cacodylate solution and dehydrated in increscent concentrations of ethyl alcohol. The microhardness (n=30) was held pre and post radiotherapy with 50gf on cervical, middle and occlusal enamel and 25kg on superficial, middle and deep dentin, both cases with 30s. The microshear-bond was divided in 4 groups (n=20) and 2 subgroups (n=10) according to the adhesive system. Three cylinders were built with 1mm in diameter and heigh in every sample. The assay were accomplished at an universal testing machine with 1mm/min. Results indicate loss of microhardness properties only in cervical enamel at all 3 doses (20Gy pre-radiotheraphy: 298,04 ± 11,80 and post-radiotherapy: 294,36 ± 16,68; 40Gy pre-radiotherapy: 285 ± 19,45 and post-radiotherapy: 275,3 ± 36; 70Gy pre-radiotherapy: 291,98 ± 16,51 and post-radiotherapy: 283,68 ± 21,64) and in all dentin depths (deep: 20Gy preradiotherapy: 57,79 ± 1,96; post-radiotherapy: 55,37 ± 1,30; 40Gy pre-radiotherapy: 57,31 ± 1,76; post-radiotherapy: 55,83 ± 1,63; 70Gy showed no alteration; Middle: 20Gy pre-radiotherapy: 58,05 ± 1,79; post-radiotherapy: 55,36 ± 1,20; 40Gy preradiotherapy: 57,87 ± 2,04; post-radiothetrapy: 55,65 ± 2,48; 70Gy showed no alteration; Superficial: 20Gy pre-radioterapia: 56,60 ± 12,17; post-radiotrapia: 55,18 ± 2,57; 40Gy pre-radiotherapy: 57,36 ± 2,78; post-radiotherapy: 55,18 ± 2,57; 70Gy pre-radiotherapy: 55,08 ± 1,94; post-radiotherapy: 54,72 ± 2,57). The microshearbond test did not show significant difference between the control group and the 3 doses, both enamel (p=0.325) and dentin (p=0.719), showing better bonding with Universal Single Bond adhesive in dentin. The fracture pattern analysis indicated a larger number of cohesive failure in dentine with the 70Gy dose when compared with control group. The micrographs showed changes only on enamel at 70Gy dose, with shorter and rounder prisms. EDS test indicated no changes in mineral content for both substrates. Knowing the limitations of an in vitro study, it were concluded that ionizing radiation shows deleterious effects preferentially in dentin, probably due to it\'s high organic content, since EDS showed no modifications both enamel and dentin. There is a reduction in microhardness on dentin, but the changes are not enough to interfere at bonding properties of irradiated substrates, showing better results when used the universal adhesive with the self-etch techniques.
19

Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina / Influence of self-etch adhesive on bond strength of resin-modified glass ionomer to dentin

Menegatti, Giovanna Emann Tavares 12 May 2016 (has links)
A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs. / This research aims to evaluate the influence of five dentin pretreatments on microshear bond strength of four resin-modified glass ionomer (RMGI). The experiment was performed in vitro, using 200 bovine incisors. From these, there were obtained 200 dentine fragments that were randomly distributed into 20 groups (n = 10) according to the variation factors comprising five dentin treatment (control group, i.e., no treatment; Polyacrylic Acid 20%; Clearfil SE Bond; Single Bond Universal and Vitremer Primer) and four glass ionomer cements (GC Fuji II LC® CAPSULE; GC Fuji LC LINING® (Paste Pak); Vitrebond® and Vitremer). After preparation of the samples and 24h storage at 37 °C, was performed microshear test in a universal testing machine (Instron 5942 - Canton, MA, USA) with speed of 1mm/min, followed by analysis of the pattern fractures in digital microscope. Statistical analysis of the 400 results was performed by ANOVA nonparametric test for two variation factors (cement and treatment) (p <0.05%) and the post-hoc Tukey (p <0.05%). The tests demonstrated there are statistical difference between treatments, cements and between the interaction of both (p <0.0001). The Clearfil SE (X?=18,26 ± 2,78) and SingleBond (X?=17,28 ± 2,49) promoted the highest bond strength values compared to the other treatments, but showing no statistical difference between them, which represented an increase in bond strength of 121% for Clearfil SE and 109.2% for Single Bond Universal compared to control group. The Polyacrylic Acid (X?=9,94 ± 3,55) has reached intermediate values, corresponding to a 20% increase in adhesive strength compared to control group. This treatment differed significantly from the higher values, but showed no difference compared to Primer Vitremer (X?=8,91 ± 2,97). The control group (X?=8,26 ± 4,17) showed the lowest values, statistically differing from the adhesives and polyacrylic acid, but with results that matched to the treatment with Vitremer Primer. When analyzing the interaction between cement and treatment, all cements tested in this study had higher results when one of the adhesive systems was used as dentin treatment, regardless of which adhesive system. Based on these results, it could be concluded that the two adhesive systems were able to significantly improve the adhesive strength of RMGIs.
20

Efeito do tipo de monômero ácido  empregado em cimentos resinosos autoadesivos experimentais, nas propriedades físico-químicas do cimento e na sua resistência de união à dentina e à Y-TZP / Effect of acid monomer type used in experimental self-adhesive luting cements about physico-chemical properties and bond strength to dentin and Y-TZP

Albuquerque, Pedro Paulo Albuquerque Cavalcanti de 03 June 2015 (has links)
Objetivos: o presente estudo teve como objetivo determinar a aplicabilidade e eficácia adesiva de diferentes monômeros ácidos quando aplicados em formulações de cimentos resinosos autoadesivos experimentais sob o grau de conversão, propriedades físico-químicas e resistência de união à dentina e à zircônia tetragonal policristalina estabilizada por ítrea (Y-TZP), após um período de 3 meses de armazenamento em água. Material: dois tipos de cimentos do tipo pasta-pasta foram formulados contendo monômeros convencionais UDMA, HEMA, BISGMA, TEGDMA e monômeros ácidos 2MP e GDMAP como matriz orgânica. Um grupo contendo apenas monômeros convencionais foi formulado como grupo controle. Os componentes canforoquinona/EDMAB e peróxido de benzoíla/DHPT foram empregados como sistema de ativação dual. O sal sódico do ácido benzenosulfônico 98% (BAS) foi incorporado nos grupos experimentais. Partículas de carga foram incorporadas na proporção ±55% em peso final. Método: A técnica de espectroscopia no infravermelho (FT-IR) foi empregada para análise do grau de conversão (n=3) imediato e após 24 h. A avaliação do pH (n=3) foi feita através do emprego de um equipamento medidor de pH. Os corpos de provas foram imersos em água destilada e o pH foi analisado de forma imediata e após 5 min, 24 h e 48 h. Os testes de sorção e solubilidade (n=6) e espessura de película (n=5) seguiram as recomendações da ISO 4049. A análise de resistência de união (n=12) foi realizada em dentina e Y-TZP, através do teste de cisalhamento em área reduzida após um protocolo de envelhecimento em água destilada por 3 meses. No caso da Y-TZP, metade dos espécimes receberam um tratamento superficial cojet (30 ?m), associado a aplicação de um agente de união silano. O padrão de fratura foi analisado com o auxílio de um estereomicroscópio. Resultados: O grupo controle (91,7%) e o grupo formulado com 2MP (92%) apresentaram superiores valores de grau de conversão em relação ao grupo GDMAP (77,7%). O pH dos grupos experimentais 2MP e GDMAP se apresentou mais ácido após 48 h em comparação ao grupo controle. Em contrapartida, esses grupos experimentais apresentaram uma maior sorção e solubilidade em relação ao grupo controle. A espessura da película formada foi semelhante em todos os grupos testados (p=0,266). Em dentina o grupo controle (27,0 MPa) e GDMAP (24,1 MPa) não apresentaram diferença estatística após 3 meses de estocagem. O grupo 2MP (13,7 MPa) apresentou resultados inferiores aos demais grupos. O tratamento de superfície empregado não foi capaz de manter ou de elevar os valores de resistência de união à Y-TZP após o período de envelhecimento em água. Todos os grupos experimentais apresentaram falhas precoces ou baixos valores de resistência de união após 3 meses, independente da presença ou não do tratamento de superfície. Conclusão: os grupos experimentais 2MP e GDMAP apresentaram resultados promissores. Entretanto, a adesão dos CRAs experimentais testados em Y-TZP ainda se apresenta frágil e instável. / Objectives: the purpose of this study was to evaluate the applicability and adhesive efficiency of different acid monomers utilized in formulations of experimental self-adhesive resin cement under degree of conversion, physico-chemical properties and bond strength to dentin and Y-TZP after 3 months aging period. Materials: two paste-paste luting agents were formulated containing UDMA, HEMA, BISGMA, TEGDMA and acid adhesive monomers 2MP and GDMAP as organic matrix. The control group was formulated containing only conventional monomers. Camphoroquinone/EDMAB and benzoyl peroxide/DHPT were used as dual activation system. BAS salt was incorporated into the experimental groups. Filler particles were added in a proportion of ±55% final weight. Method: Infrared spectroscopy technique (FTIR) was employed for degree of conversion analysis (n=3) immediately and after 24 hours. The pH assessment (n=3) was made using a pH meter. All the specimens were immersed in distilled water and pH assessment was performed immediately and after 5 min, 24 h and 48 h. Tests for sorption and solubility (n=6) and thickness (n=6) were carried out according to ISO 4049 recommendations. Bond strength analysis (n=12) was performed in dentin and Y-TZP through microshear after an aging 3 months protocol in distilled water. Regarding Y-TZP, half of the specimens were submitted to a cojet surface treatment (30 ?m) in association to silane bonding agent application. Fracture toughness standard was evaluated with the assistance of a stereomicroscope. Results: The control (91,7%) and 2MP (92%) groups presented higher degree of conversion than GDMAP group (77,7%). The 2MP and GDMAP experimental groups showed the highest pH compared to control group. In contrast, experimental groups showed a high hydrolytic degradation. The thickness of the formed film was similar among all the tested groups (p=0,266). Regarding the dentin, control and GDMAP groups had statistically similar bond strength (27,0 and 24,1 MPa respectively) after 3 months storage. While 2MP group (13,7 MPa) showed lower results compared the other groups. The surface treatment employed was not capable to maintain or elevate bond strength to Y-TZP results after the aging period in water. All experimental groups showed low bond strength values and even early failures after 3 months, regardless the surface treatment or its abscence. Conclusion: the experimental groups 2MP and GDMAP presented promising results. However, chemical adhesion to Y-TZP still remains weak and instable.

Page generated in 0.0572 seconds