• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 134
  • 1
  • Tagged with
  • 137
  • 109
  • 91
  • 88
  • 73
  • 67
  • 54
  • 50
  • 49
  • 39
  • 36
  • 34
  • 32
  • 24
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação das técnicas de microextração e eletroforese capilar em meio não aquoso (NACE) para determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica / Evaluation of microextractions techniques and nonaqueous capillary electrophoresis (NACE) for the determination of antidepressants in plasma samples for therapeutic drug monitoring

Catai, Ana Paula Formenton 02 March 2012 (has links)
A monitorização terapêutica tem sido descrita como um recurso clínico valioso, na individualização do regime de dosagem, de acordo com a concentração do fármaco em amostras de plasma ou soro. O objetivo da monitorização terapêutica é assegurar a eficácia clínica e minimizar os efeitos adversos dos fármacos prescritos na clínica. A química analítica moderna tem sido direcionada para a simplificação dos métodos através da miniaturização dos sistemas analíticos, minimização do consumo de solvente orgânico e do volume da amostra. Neste contexto, metodologias analíticas utilizando as técnicas de microextração, extração sortiva em barra de agitação (SBSE) e microextração em sorvente empacotado (MEPS), juntamente com a eletroforese capilar em solução não-aquosa (NACE) foram desenvolvidas para fins monitorização terapêutica de antidepressivos inibidores seletivos da recaptação de serotonina (ISRSs: fluoxetina, sertralina, paroxetina e citalopram) em amostras de plasma de pacientes em terapia com ISRSs. Inicialmente foram padronizadas as condições eletroforéticas com detecção espectrofotométrica (UV) para análise simultânea dos ISRSs em amostras de plasma. Dentre as condições avaliadas (diferentes soluções de eletrólitos em meio aquoso e não aquoso, cromatografia eletrocinética micelar e NACE), a técnica NACE-UV foi a única que apresentou resolução dos fármacos adequada. Em seguida, otimizou-se as variáveis inerentes das técnicas de microextração (SBSE e MEPS), visando minimizar o tempo de análise e aumento da sensibilidade analítica. Para o método SBSE/NACE, as variáveis tempo e temperatura de extração, pH da amostra biológica e processo de dessorção foram otimizadas, já para o método MEPS/NACE, as variáveis, pH da amostra biológica, volume da amostra e número dos ciclos aspirar/dispensar foram otimizadas. A validação analítica foi realizada segundo as normas preconizadas pela Agência Nacional de Vigilância Sanitária (ANVISA), com adição de padrão de padrão interno às amostras de plasma enriquecidas com os antidepressivos em diferentes concentrações plasmáticas que contemplam o intervalo terapêutico dos ISRSs. Para avaliar a aplicabilidade das metodologias padronizadas, amostras de plasma de pacientes em terapia com os ISRSs foram analisadas. Os métodos padronizados (SBSE/NACE e MEPS/NACE) foram comparados ao método de referência (LLE/NACE), utilizando a extração líquido-líquido. As técnicas de microextração, quando comparadas à LLE, apresentaram as seguintes vantagens: a reutilização das fases extratoras, procedimentos de extração com reduzido número de etapas, menores volumes de amostras biológicas e de solventes orgânicos. Segundo os parâmetros de validação avaliados, os métodos SBSE/NACE e MEPS/NACE padronizados podem ser empregados nas análises dos antidepressivos (ISRSs) em amostras de plasma, para fins de monitorização terapêutica. / Therapeutic monitoring allows individualization of the dose regimen and has been indicated for the monitoring of well-established therapeutic intervals. In psychiatric disorders, most of the patients require that the plasmatic concentrations to be within a fixed range, so the disorders are kept under control and the adverse effects are acceptable. The aim of the therapeutic monitoring is ensure clinical effectiveness and minimization of adverse effects of drugs prescribed at the clinic. New trends in analytical chemistry have been directed towards simplification and miniaturization of analytical systems, and minimization of organic solvents and sample volume. In this work, analytical methodologies using microextraction techniques, such as stir bar sorptive extraction (SBSE) and microextraction by packed sorbent (MEPS), in conjunction with capillary electrophoresis in a nonaqueous background electrolyte (NACE) were developed for therapeutic drug monitoring of selective serotonin reuptake inhibitors (SSRIs: fluoxetine, sertraline, paroxetine and citalopram) in plasma sample of patients in therapy with SSRIs. First, the optimization of electrophoretic separation of the SSRIs was carried out to obtain simultaneous analysis of all antidepressants. Among the conditions evaluated (different background electrolytes in aqueous and nonaqueous medium, micellar electrokinetic capillary chromatography, and NACE), NACE-UV gave the best results. In the sequence, the optimization of the inherent variables of microextraction techniques (SBSE and MEPS)aiming analyses time minimization and increase of analytical sensibilitywas carried out. For SBSE/NACE methodology development the variables such as time of extraction, temperature of extraction, and matrix pH were optimized. For MEPS/NACE methodology the variables matrix pH and the volume of draw-eject cycles were optimized. Analytical validation was carried out in agreement with the norms of National Health Surveillance Agency (ANVISA) for both of the proposed methods, in different plasmatic concentrations, which completed the therapeutic interval. The developed methods (SBSE/NACE e MEPS/NACE) were compared to the reference method, using liquid-liquid extraction (LLE/NACE). Microextraction techniques, compared to LLE, gave the following advantages: reutilization of the extraction phase, fewer numbers of steps for extraction, reduction of sample volume, and less consumption of organic solvents. According to the evaluated validation parameters, the standardized methods SBSE/NACE and MEPS/NACE can be used in the analyses of antidepressants (SSRIs) in plasma sample for therapeutic drug monitoring purposes.
122

Síntese de novos materiais à base de grafeno para aplicação em microextração por sorvente empacotado MEPS na extração de tetraciclinas presentes no leite com posterior análise por cromatografia líquida acoplada a espectrometria de massas sequencial <i / MEPS-HPLC-MS/MS determination of tetracyclines in milk sample utilizing graphene-particles supported on sílica as sorbent phase

Edvaldo Vasconcelos Soares Maciel 27 July 2017 (has links)
O crescimento da população mundial e a expansão industrial são fatores que atualmente desencadeiam um aumento no consumo de produtos e geração de resíduos. Frequentemente utilizados na medicina tradicional e veterinária, os antibióticos são classificados como uma classe emergente de poluentes, pois, devido à sua baixa taxa de degradação e à ineficácia dos sistemas de tratamentos de água, encontram-se disseminados no meio ambiente e nos alimentos. Em consequência desse fato, estudos para o desenvolvimento de novos materiais e métodos que removam estes contaminantes utilizando menor quantidade de consumíveis químicos e a baixo custo, têm sido um campo em desenvolvimento na química analítica. Inserido nesse contexto encontra-se o grafeno, que devido à sua estrutura de anéis aromáticos com elétrons &pi; deslocalizados e elevada área superficial (3600 m2/g), pode favorecer fenômenos de sorção, elevando a eficiência na extração de contaminantes presentes em matrizes complexas. O objetivo do projeto foi sintetizar e caracterizar novas fases sorventes à base de grafeno para atuar no preparo da amostra avaliando a eficácia destas na remoção de tetraciclinas presentes em leite. Para isso, utilizou-se da microextração por sorvente empacotado MEPS como método de preparo de amostra com posterior análise por cromatografia líquida acoplada a espectrometria de massas HPLC-MS/MS. A caracterização dos materiais foi feita através de microscopia eletrônica de varredura MEV e espectroscopia vibracional na região do infravermelho IV revelando eficácia na síntese das folhas de óxido de grafeno, assim como, no recobrimento das partículas de sílica com os novos materiais. Foram avaliadas as fases extratoras: G, GO-SIL, G-Sil e C18-G-Sil com relação a eficiência na extração das tetraciclinas. A fase G-Sil mostrou-se a mais apropriada para continuidade do estudo, pois apresentou os melhores resultados. Com o objetivo de otimizar a etapa de preparo de amostra, foi feito um planejamento fatorial fracionário 24-1 avaliando as variáveis químicas: solvente de eluição, força iônica, pH da solução de lavagem e inclusão de EDTA na solução tampão de Mcllvaine (pH 4.2). Posteriormente foi feito um planejamento fatorial completo 23 visando a otimização dos ciclos de extração da MEPS, possibilitando determinar a condição ótima de extração do método. Baseando-se no documento: ICH - Q2 (R1) guideline, a metodologia foi submetida a testes para avaliar as figuras de mérito referentes a validação analítica. O método apresentou faixa linear de 15 - 110 &micro;g/L, LQ entre 0,05 e 0,9 &micro;g/L e boa seletividade. A precisão foi avaliada intra e inter-dia apresentando desvio padrão relativo - RSD abaixo de 18%. Ao final do desenvolvimento do estudo foram analisadas onze amostras reais incluindo leite bovino, caprino, ovino e leite em pó. A aplicação em amostras de diferentes espécies reforça a versatilidade do método desenvolvido, além de evidenciar o elevado potencial dos novos materiais de grafeno para atuar como sorvente no preparo da amostra. / Nowadays, the rise of world population and industrial expansion are leading to an increase in consumption and consequently waste generation. Large quantities of chemical residues are released into the environment affecting humans and wildlife. Among these residues, antibiotics used in medicine and veterinary are classified as an emerging contaminant due to their low degradation rate, ineffectiveness of wastewater treatment and consequently water and food contamination. An effort has been made to develop microextraction techniques to remove these drugs using reduce volume of solvent and chemical consumable and researches of new sorbent phases are increasing due the high potential to improve these microextraction techniques. Recent studies pinpoint graphene (G) as an effectively sorbent phase to act in sample preparation. G has a structure composed by carbon nanosheets arranged in a honeycomb pattern with large surface area (3600 m2 /g) and delocalized &pi;-electrons system that suggests good interaction between them and contaminants compounds such as veterinary drugs, pesticides, personal care products etc. This study focuses to evaluate sorbent phases based upon graphene particle supported on silica to analyze Tetracycline residues present in milk. For this purpose, was used microextraction by packed sorbent - MEPS as sample preparation method with analysis by liquid chromatography and mass spectrometry. The characterization of synthesized materials was performed by scanning electron microscopy - SEM and vibrational spectroscopy in infrared region - FTIR. The results suggest that synthesis of graphene\'s particles as well as the coating of silica surface with these materials were both performed. To evaluate extraction efficiency each sorbent material: GO-Sil, G-Sil, G, C18-GO-Sil were tested in MEPS and confronted to commercial phases: C8 and C18. By the results, G-Sil was choose to application as sorbent phase. MEPS extractions were optimized and the effect of some factors was investigated by application of experimental design. Firstly, a factorial experimental design 2(4-1) was executed to evaluate chemistry variables such as elution solvent, washing solution, media ionic strength and inclusion of EDTA salt in Mcllvaine solution. After, an experimental design 23 was made in order to estimate the cycles of MEPS extraction like sampling, washing and elution steps. By the results, an optimized extraction conditional was achieved and evaluation of validation parameters was carried out on sequence based on the ICH - Q2 (R1) guide. The method showed linearity ranging from 15 - 110 &micro;g/L, LOQ values from 0,05 to 0,9 &micro;g/L and good selectivity. Precision showed relative standard deviation RSD less than 18% to intra and inter-day analysis. The developed method was applied in analysis of eleven milk samples including bovine, caprine and ovine milk and milk powder. Application in samples from different species enhances the versatility of this analytical method and show the great potential for graphene\'s particles to act as sorbent phase in sample preparation.
123

Avaliação do emprego da técnica MEPS na análise de agrotóxicos em caldo de cana-de-açúcar por GC-MS / Evaluation of MEPS technique applied in pesticides analysis in sugarcane juice by GC-MS

Bruno Henrique Fumes 12 February 2015 (has links)
O uso de técnicas miniaturizadas de preparo de amostra vem se tornando uma tendência cada vez mais crescente em química analítica. Dentre elas o MEPS (Microextraction by a Packed Sorbent) apresenta grande potencial por poder ser acoplado on-line, sem grandes modificações, à cromatografia gasosa e líquida, não necessitando de grande quantidade de tempo para análise e seu cartucho sorvente ser reutilizável. O uso de MEPS, foi mais explorado até o presente momento na análise de fármacos em fluídos biológicos; dessa forma existe um pequeno número de publicações que exploram o uso dessa técnica na determinação de agrotóxicos em matrizes de alimentos. Por esse motivo, o presente trabalho teve como objetivo a avaliação do uso dessa técnica na determinação de seis agrotóxicos utilizados no cultivo da cana-de-açúcar (tebutiurom, carbofurano, atrazina, metribuzim, ametrina e bifentrina) em amostras de garapa. Para o desenvolvimento desse estudo foram verificadas dentre as variáveis pH, força iônica, solvente de eluição e volume do solvente de eluição, quais poderiam afetar o desempenho da técnica em diferentes fases extratoras, empregando nessa etapa de otimização planejamento fatorial fracionário 24-1. As fases avaliadas foram C18 Chromabond e HLB Oasis, assim como sistemas comercialmente disponíveis com as fases C18, C8, SAX, SCX e SIL. Durante essa etapa foi realizado um estudo inicial do uso do grafeno como material sorvente em MEPS, considerando as propriedades que esse material apresenta para atuar como adsorvente em técnicas de preparo de amostra. Contudo, o uso do grafeno apresentou entupimento no cartucho de sorção, problema ainda em avaliação. A fase C18 Chromabond foi a que apresentou os melhores resultados, sendo a escolhida para otimização dos parâmetros envolvidos na etapa de extração por MEPS. Os parâmetros otimizados por planejamento fatorial 23 foram os ciclos de: aspiração da amostra, lavagem e eluição. O método desenvolvido foi validado baseado nos critérios exigidos pelo MAPA e apresentou seletividade, linearidade e os limites de quantificação variaram de 2-10 &mu;g/L. A recuperação foi adequada para todos os analitos (71,7-106,9%), assim como a precisão intra e inter-dia que apresentou coeficientes de variação (CV) menores que 16%. O método desenvolvido foi aplicado em quatro amostras reais de garapa de diferentes regiões. / The use of miniaturized techniques in sample preparation has becoming a growing trend in analytical chemistry. Among these techniques MEPS (Microextraction by a Packed Sorbent) presents a great potential affording on-line coupling, without much modification to gas and liquid chromatography systems, in addition it does not require large analyses time and the sorbent cartridge is reusable. MEPS utilization has been explored mainly for drugs analyses in biological fluids, existing limited number of publications that apply this technique for pesticides analyses in food sample matrix. For this reason the goal of present work was the evaluation of MEPS in the analyses of six pesticides used in sugarcane cultivation (tebuthiuron, carbofuran, atrazine, metribuzine, ametryn and bifenthrin) in sugarcane juice samples. During the method development several variables were evaluated including pH, ionic strength, elution solvent and solvent volume, to determine which ones could affect the technique perform in different sorbent phases. For this optimization step, fractional factorial design 24-1 was utilized. Phases evaluated included C18 Chromabond and HLB Oasis, and also commercially available system containg C18, C8, SAX, SCX e SIL. During this step, it was also carried out an initial study employing graphene in a MEPS system; Tanking into account the properties that this material presents to act as adsorbent in sample preparation techniques. However the graphene showed obstruction problems in the sorption cartridge, whose solution is under way. The phase C18 Chromabond showed better results, and was chosen to MEPS parameters optimization. MEPs parameters optimized by full factorial desing 23 were the following cycles: sample aspiration, washing and elution. The method, was validated based upon the MAPA requirements and showed good selectivity, linearity an quantifications limits ranging from 2-10 &mu;g/L. Recovery was satisfactory for all pesticides (71,7-106,9%), intra- and inter-day precision were satisfactory and showed coefficients of variation (CV) less than 16%. Hence, the developed method was applied to the analysis of four real samples of sugarcane juice obtained from different regions.
124

Microextração de canabinoides em urina usando dispositivo empacotado com polímero molecularmente impresso e análise por cromatografia líquida - espectrometria de massas sequencial / Microextraction of cannabinoids in urine using device packed with molecularly imprinted polymer and analysis by liquid chromatography - sequential mass spectrometry

Douglas Morisue Sartore 30 July 2018 (has links)
O preparo da amostra é uma das etapas mais importantes em toda a análise química. O isolamento e a concentração dos componentes da amostra são cruciais e busca-se sempre que essas etapas sejam as mais simples e consumam o mínimo possível de tempo e reagentes. Nos últimos anos, um tipo de material tem se mostrado bastante útil para análises químicas a partir de fluidos biológicos, os polímeros molecularmente impressos (MIPs). Os MIPs são sintetizados por reações de polimerização, na presença de uma molécula molde (template). A molécula molde se liga aos monômeros funcionais do polímero durante a reação de polimerização e permanece ligada à superfície das cadeias poliméricas quando a reação se completa. Terminada a polimerização, realiza-se a completa lavagem das moléculas molde, assim, restam na superfície polimérica cavidades tridimensionais complementares à molécula empregada como molde. Essas cavidades permitem a ligação reversível e preferencial da molécula molde ou outras com estrutura química semelhante. A Cannabis sativa é a droga ilícita mais consumida em todo o mundo e nos últimos anos muita atenção tem se voltado a seus efeitos toxicológicos no corpo humano e a aplicações medicinais. Nesta dissertação, foi sintetizado um MIP com a molécula molde catequina para a extração e posterior análise por LC-MS/MS dos canabinóides &Delta;9-tetrahidrocanabinol (THC), 11-hidroxi-&Delta;9-tetrahidrocannabinol (THC-OH) e 11-nor-&Delta;9-tetrahidrocannabinol-9-ácido carboxílico (THC-COOH) em amostras de urina. O MIP produzido foi empacotado em microdispositivo e empregado no preparo das amostras de urina por microextração por sorvente empacotado (MEPS). O método desenvolvido apresentou boa linearidade (valores de r de 0,977 para o THC e 0,994 para THC-OH e THC-COOH). Os limites de detecção e de quantificação foram respectivamente de 5 ng mL-1 e 20 ng mL-1, para os compostos THC e THC-OH, na faixa linear de 25 a 250 ng mL-1. Para o composto THC-COOH os limites de detecção e quantificação alcançados foram de 1 ng mL-1 e 5 ng mL-1, respectivamente, na faixa linear de 5 a 170 ng mL-1. O método apresentou valores razoáveis de precisão entre 3,2% (THC-COOH) e 25,1% (THC) e de exatidão, que variou entre -18,4 e 17,4 (ambos para o THC). O MIP empregado no preparo da amostra mostrou-se mais seletivo e específico do que materiais normalmente empregados para a extração dos canabinoides das amostras de urina, além de a técnica de extração por MEPS apresentar baixo consumo de solventes e amostra para a extração dos analitos e posterior análise por LC-MS/MS. / The sample preparation is one of the most important steps in every chemical analysis. The isolation and concentration of the sample components are crucial and it is always sought that these steps are simple and consume the lowest amount of time and reagents. In the recent years, a type of material has proved to be very useful for chemical analyzes of biological fluids, the molecularly imprinted polymers (MIPs). MIPs are synthesized by polymerization reactions in the presence of a template molecule. The template molecule binds to the functional monomers of the polymer during the polymerization reaction and remains bonded to the surface of the polymeric chains after the reaction is complete. After the polymerization is finished, the complete washing of the template molecules is carried out, thus, three-dimensional cavities, complementary to the molecule used as a template, remain on the polymer surface. These cavities allow the reversible and preferential bonding of the template molecule or others with similar chemical structure. Cannabis sativa is the most commonly consumed illicit drug in the world and in recent years much attention has focused on its toxicological effects on human body and for medical applications. In this master dissertation, a MIP was synthesized with the catechin molecule as template, for extraction and subsequent analysis by LC-MS/MS of the cannabinoids &Delta;9-tetrahydrocannabinol (THC), 11-hydroxy-&Delta;9-tetrahydrocannabinol (THC-OH), and 11-nor-&Delta;9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in urine samples. The MIP produced was packed in a microdevice and used in the preparation of the urine samples by microextraction by packed sorbent (MEPS). The developed method showed good linearity (r values of 0.977 for THC and 0.994 for THC-OH and THC-COOH). The detection and quantification limits were respectively 5 ng mL-1 and 20 ng mL-1 for THC and THC-OH in the linear range from 25 to 250 ng mL-1. For the compound THC-COOH the limits of detection and quantification achieved were 1 ng mL-1 and 5 ng mL-1, respectively, in the linear range from 5 to 170 ng mL-1. The method presented reasonable values of precision, between 3.2% (for THC-COOH) and 25.1% (for THC) and displayed accuracy ranging from -18.4 to 17.4 (both for THC). The MIP used in the sample preparation was more selective and specific than other materials usually employed for the extraction of the cannabinoids from the urine samples. The MEPS technique also showed low consumption of solvents and sample for sample preparation, extraction of analytes and subsequent analysis by LC-MS/MS.
125

Desenvolvimento de métodos para coleta e determinação de poluentes em fase gasosa da atmosfera utilizando amostragem por difusão com membranas capilares microporosas / Development of methods for sampling and determination of gaseous pollutants in the atmosphere using diffusional microporous capillary membrane scrubber

Coelho, Lúcia Helena Gomes 23 November 2009 (has links)
A tese enfatiza o desenvolvimento e aplicação de amostradores difusionais para pré-concentração de traços de poluentes gasosos e sua conjugação com técnicas de separação e determinação, especialmente, a eletroforese capilar. Foram implementadas novas aplicações para um amostrador com múltiplos filamentos microporosos de polipropileno, previamente desenvolvido pelo grupo de pesquisa, e para o novo dispositivo de coleta de dimensões reduzidas, composto por monofilamento microporoso de polipropileno (CMDS) com volume interno de 30 &#181;L. Para o estabelecimento da vazão estável em 1,0 &#181;L min-1 de fase aceptora pelo capilar poroso, recorreu-se à pressurização do reservatório com uma bomba pneumática de aquário e regulagem de vazão por um capilar de sílica fundida e uma válvula de agulha. Outra bomba pneumática foi utilizada para aspirar o fluxo de ar amostrado. As amostras foram coletadas seqüencialmente em frascos de 200 &#181;L, mantidos sob temperatura reduzida em unidade de refrigeração do tipo Peltier acoplado ao amostrador. O CMDS monofilamentar, mais compacto e robusto, apresentou alta eficiência de coleta para a pré-concentração de formaldeído (CH2O), ácidos fórmico e acético e amônia da fase gasosa da atmosfera. Para as espécies com elevada constante de Henry, água deionizada serviu como fase aceptora, enquanto que para amônia, recorreu-se ao deslocamento do equilíbrio por um aceptor ácido, de modo a reter o analito na forma de NH4 +. A concentração das espécies em fase líquida foi determinada posteriormente por eletroforese capilar com detecção condutométrica sem contato (CE-C4D). Os limites de detecção, em fase líquida, para formiato, acetato, formaldeído (determinado na forma do aduto hidroximetanosulfonato HMS) e amônio foram estimados em 1,0, 1,5, 1,2 e 1,2 &#181;mol L-1, respectivamente (equivalentes à 0,9, 3,0, 1,0 e 0,7 &#181;g m-3 dessas espécies na atmosfera, respectivamente). Para a determinação de CH2O por injeção em fluxo (FIA) acoplada à detecção amperométrica em eletrodo de ouro platinizado, fez-se uso do coletor multifilamentar, por atender melhor à necessidade de volume de amostra. A interferência de espécies comumente presentes na atmosfera, como H2O2 e SO2, pôde ser contornada realizando coletas em presença de peróxido de hidrogênio para promover a oxidação do S(IV) à S(VI) e, posteriormente, destruindo o oxidante em reator contendo enzima catalase imobilizada. A determinação de CH2O foi implementada com sucesso por FIA com detecção por amperometria em eletrodo de ouro platinizado. Um CMDS portátil que funciona à pilha, próprio para amostragens em campo, foi desenvolvido utilizando, para o deslocamento do ar amostrado, uma bomba de pistão retirada de aparelho automático para medida de pressão arterial. O amostrador foi empregado na coleta de H2S, SO2 e alquil-mercaptanas em fase gasosa da atmosfera, utilizando fase aceptora alcalina para promover a desprotonação e conseqüente fixação das espécies em meio líquido. Os analitos foram determinados por CE-C4D ou por microextração em fase sólida (SPME) seguida de determinação por GC. O uso conjunto do antioxidante ascorbato para conservação das amostras e de etanol para fixação dos compostos voláteis em meio aquoso permitiu o estabelecimento de um protocolo completo para coleta e detecção dessas espécies reduzidas de enxofre, com sensibilidade suficiente para monitorar emissões de origem biogênica, o que foi exemplificado na prática coletando amostras próximo a um córrego contaminado com esgoto. A perfeita combinação do diminuto volume de fase aceptora do CMDS com a demanda de nanolitros de amostra da CE-C4D culminou com o desenvolvimento de um sistema de análise total (TAS) com gerenciamento de fluidos baseado em propulsão por bombas de aquário (de baixo custo e alta durabilidade) e válvulas solenóide de estrangulamento, controladas por computador. Como exemplo de aplicação inovador e bem sucedido do TAS desenvolveu-se a análise concomitante e em tempo quase real de ácidos fórmico e acético no ar, com freqüência de 10 pares de dados por hora. As vantagens do sistema CMDS-CE-C4D incluem simplicidade, versatilidade, consumo de reagentes e amostra e geração de resíduos minimizada, robustez e rapidez enquanto uma amostra é coletada, o eletroferograma da anterior é adquirido sem necessidade de bombas de alta pressão ou colunas dispendiosas como as requeridas para HPLC / The development and application of porous membrane diffusion samplers for fast and efficient pre-concentration of an array of trace air pollutants was emphasized in this thesis, in conjunction with compatible separation and determination techniques, especially capillary electrophoresis. New applications were found for a formerly developed diffusion scrubber based on a bundle of microporous hollow polypropylene capillary membranes and for a scaled down version with a single core capillary membrane diffusion scrubber (CMDS) comprising an internal volume of 30 &#181;L, were used for sampling of the trace level pollutants to an adequate liquid acceptor. The low-flow of acceptor solution, 1.0 &#181;L min-1, required by the CMDS was satisfied by pressurization of the reservoir with an aquarium pump combined with flow regulation by a silica capillary as hydrodynamic resistor and a needle valve. Another aquarium pump was used for the aspiration of the sampled air through the sampler. The low volumes collected in the CMDS were stored in 200 &#181;L vials inserted in a cooling plate of a Peltier device. The robust and compact system was used for sampling of formaldehyde (CH2O), formic acid, acetic acid and ammonia in the gaseous phase of the atmosphere. For chemical species with high Henry´s constant, deionized water suffices as acceptor phase. Otherwise, equilibria displacement to a non-volatile ion, like NH4 + for NH3 sampling, promoted quantitative retention in the acceptor phase. The concentrations of the analytes in the liquid phase were determined by capillary electrophoresis with capacitively coupled contactless conductometric detection (CEC4D). The detection limits obtained in the liquid phase for formate, acetate, formaldehyde (in the form of the adduct hydroxymethanesulfonate HMS) and ammonium were 1,0, 1,5, 1,2 e 1,2 &#181;mol L-1 respectively (what corresponds to 0,9, 3,0, 1,0 e 0,7 &#181;g m-3 of the respective gaseous species in the air). The higher volume of acceptor phase provided by the sampler with a bundle of microporous membrane capillaries (~600 &#181;L) are in tune with the needs of flow injection analysis (FIA), as demonstrated for amperometric detection of CH2O on a platinized gold electrode. The interferences from SO2 and H2O2 were overcome by adding H2O2 to the acceptor solution to promote the oxidation of S(IV) to S(VI) and destruction of the oxidant afterwards in a column with immobilized catalase enzyme. The aquarium pump used for gas aspiration was substituted to a piston pump, taken from arterial blood pressure meter fed with 8 V D.C., to turn possible field collections with the CMDS device. The system was used for the sampling of H2S, SO2 e alkyl-mercaptans in the gaseous phase of the atmosphere. To succeed on that, the samplings were performed in alkaline media to promote deprotonation of the species (and stabilization in non-volatile forms). The collected analytes were determined by CE-C4D or by solid phase microextraction (SPME) followed by GC analysis. The joint use of the antioxidant ascorbate for sample preservation and ethanol for fixation of the volatile compounds allowed the establishment of a complete protocol for sampling, storage and detection of the sulfur reduced species with enough sensitivity for monitoring biogenic emissions from waste discharge. Perfect matching of the low-volume characteristics of the CMDS device and the CE-C4D equipment led to the conception of a low-cost automatic CMDS-CE-C4D total analysis system (TAS) and its innovative and successful application to near-realtime simultaneous analysis of formic acid and acetic acid in air. During the evaluation of one sample, the TAS collects a new one, with valves, pumps and high voltage delivery under software control. Advantages include rapidity (10 data points per hour for each analyte), high preconcentration efficiency, simplicity and versatility, minimum sample and reagent consumption and residue generation (green analytical method), no need of costly high pressure pumps and separation columns like those used in HPLC
126

Influência de diferentes porta-enxertos na composição química dos óleos essenciais e do suco de tangerinas Fremont IAC 543 / The influence of different rootstocks in the essential oils chemical composition and juice volatiles from mandarin Fremont IAC 543

Marques, Stéphano 26 April 2019 (has links)
O objetivo desta pesquisa foi investigar a influência de diferentes porta-enxertos (Limão Cravo, Citrumelo Swingle, Trifoliata e Trifoliata Flying Dragon) na composição química dos óleos essenciais e dos voláteis do suco integral de tangerinas Fremont IAC 543. Os óleos essenciais da casca dos frutos foram obtidos por hidrodestilação, e variaram de 0,36 a 0,47% (v/m), sendo que a tangerina cultivada em porta-enxerto Trifoliata Flying Dragon foi a que apresentou menor rendimento de óleo essencial. A caracterização química dos óleos essenciais foi realizada por cromatografia gasosa acoplada a espectrometria de massas (GC-MS) e a semi-quantificação dos componentes dos óleos essenciais foi realizada por cromatografia gasosa acoplada a detector de ionização em chama (GC-FID). Os compostos majoritários dos óleos essenciais das variedades estudadas foram limoneno, linalol e mirceno, os quais são responsáveis por mais de 95% da área relativa dos componentes dos óleos essenciais. Devido à maior produtividade do porta-enxerto Citrumelo Swingle (18 L/ha), este é o mais indicado para produção de óleo essencial de tangerina Fremont IAC 543. Para a caracterização dos voláteis presentes no suco integral da tangerina Fremont IAC 543 foi realizada a otimização multivaridada da extração dos voláteis do suco por microextração em fase sólida de headspace (HS-SPME). Encontrou-se que a melhor condição para a extração dos voláteis consistiu no uso de fibra de divinilbenzeno/polidimetilsiloxano (DVB/PDMS), temperatura de extração de 43 °C e tempo de 31 min. Os principais compostos voláteis dos sucos integrais estudados foram o limoneno, mirceno, linalol, decanal, &alpha;-pineno, havendo bastante variação na composição dos voláteis dos sucos integrais de acordo com o porta-enxerto utilizado. Os espectros de Ressonância Magnética Nuclear mostraram que os sucos das quatro amostras analisadas possuem perfis complexos, porém semelhantes. A tangerina cultivada com porta-enxerto de Limão Cravo apresentou maiores valores de ácido málico e tirosina. A tangerina enxertada com Citrumelo Swingle apresentou maiores quantidades de ácido cítrico e etanol. A variedade plantada sobre o porta-enxerto de Trifoliata apresentou maiores valores de alanina, glicose e sacarose. A amostra cultivada sobre o porta-enxerto de Trifoliara Flying Dragon apresentou menor quantidade de etanol. Através da análise de componentes principais foi possível diferenciar as amostras a partir de seus componentes de óleo essencial e compostos voláteis e não-voláteis do suco integral de cada variedade plantada em diferentes porta-enxertos. / The objective of this research was to investigate the influence of different rootstocks (Clove Lemon, Citrumelo Swingle, Trifoliata and Trifoliata Flying Dragon) on the chemical composition of the essential oils and volatiles of the Fremont IAC 543 mandarin. The essential oils from the fruit peels were obtained by hydrodistillation, and ranged from 0.36 to 0.47% (v/w) and the mandarin cultivated in Trifoliata Flying Dragon rootstock showed the lowest essential oil yield. The chemical characterization of the essential oils was performed by gas chromatography coupled to mass spectrometry (GC-MS) and the semi-quantification of essential oil components was performed by gas chromatography coupled to a flame ionization detector (GC-FID). The major essential oils compounds were limonene, linalool, and myrcene, which were responsible for more than 95% of the essential oil components. Due to the higher productivity of the Citrumelo Swingle rootstock (18 L/ha), this was the most suitable rootstock for the Fremont IAC 543 mandarin essential oil production. Aiming the characterization of the Fremont IAC 543 mandarin juice volatiles compounds, a multivariate optimization of juice volatiles extraction by headspace solid phase microextraction (HS-SPME) was performed. It was found that the best volatile extraction conditions were the use of divinylbenzene/polydimethylsiloxane (DVB/PDMS) fiber, 43 ° C for extraction temperature and 31 min for extraction time. The main volatile compounds of the whole juices studied were limonene, myrcene, linalool, decanal and &alpha;-pinene. It possible see a considerable variation in the volatile composition of whole juices according to the rootstock used. Nuclear Magnetic Resonance spectras showed that the juices of the four samples analyzed had complex but similar profiles. Tangerine cultivated with Lemon Cravo rootstock showed higher values of malic acid and tyrosine. Tangerine growth in Citrumelo Swingle showed higher amounts of citric acid and ethanol. The variety planted on the rootstock of Trifoliata showed higher values of alanine, glucose and sucrose. The sample cultivated on the Trifoliara Flying Dragon rootstock showed less ethanol. Through the principal component analysis, it was possible to differentiate the samples using their essential oil components and volatile and non-volatile compounds from the integral juice of each variety planted in different rootstocks.
127

Desenvolvimento de método de quantificação de estatinas em efluente hospitalar e estudo de degradação oxidativa avançada / Method development of statins quantification in hospital effluent and study of advanced oxidative degradation

Altissimo, Joseline 18 December 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this study, an analytical method was developed for the quantification of statins Atorvastatin and Simvastatin, in hospital effluent (University Hospital of Santa Maria, using Solid phase extraction and Dispersive liquid-liquid microextraction, followed in liquid chromatography coupled to diode array detector. The principal variables of Dispersive liquid-liquid microextraction were investigated with aid of experimental central composite design. The recovery rates of Solid phase extraction varied from 95% for Atorvastatin and 83.2% for Simvastatin, in aqueous solution, and 92.0% for Atorvastatin and 81.5% for Simvastatin, in hospital effluent. As for the Dispersive liquid-liquid microextraction the recovery rates ranged from 85.5% for Atorvastatin and 89.4% for Simvastatin, in aqueous solution, and 83.0% for Atorvastatin and 83.1% for Simvastatin, in hospital effluent. The sampling was carried out in two sample points called Emergency Effluent and General Effluent . The concentration rates detected in the effluent were 30.1 μg L-1 in Emergency Effluent and 29.0 μg L-1 in General Effluent for Atorvastatin and 37.1 μg L-1 in Emergency Effluent and 36.1 μg L-1 in GE for Simvastatin. Ozonation and electrocoagulation were applied for the degradation/removal of statins. The principal variables of electrocoagulation were investigated with aid of experimental central composite design. The degradation rate obtained in ozonation was 100% for Atorvastatin, in 25 minutes reaction for aqueous solution and hospital effluent; and 100% for Simvastatin, in 4 minutes reaction for aqueous solution and 10 minutes reaction in hospital effluent. As for the electrocoagulation the removal rate was 75.6% in aqueous solution and 70.9% in hospital effluent for Atorvastatin; and 100% in aqueous solution and hospital effluent for Simvastatin in 60 minutes reaction. A preliminary risk evaluation revealed that the statins showed a low environmental risk, PEC/PNEC < 1. / Neste trabalho foi desenvolvida metodologia analítica para a quantificação de estatinas Atorvastatina e Sinvastatina, em efluente hospitalar (Hospital Universitário de Santa Maria), utilizando Extração em fase sólida e Microextração dispersiva líquido-líquido seguida de cromatografia líquida com detector de arranjo de diodos. As principais variáveis da Microextração dispersiva líquido-líquido foram investigadas utilizando a Metodologia de Superfície de Resposta através de um delineamento composto central rotacional. As taxas de recuperação da Extração em fase sólida foram de 95,8% para Atorvastatina e 83,5% para Sinvastatina, em solução aquosa e 92,0% para Atorvastatina e 81,5% para Sinvastatina em efluente hospitalar. Já para a Microextração dispersiva líquido-líquido as taxas de recuperação foram de 85,5% para Atorvastatina e 89,4% para Sinvastatina, em solução aquosa e 83,0% para Atorvastatina e 83,1% para Sinvastatina, em efluente hospitalar. A amostragem foi feita em dois pontos de coleta, denominados Efluente PA e Efluente Geral . A concentração média detectada no efluente foi de 30,1 μg L-1 no Efluente PA e 29,0 μg L-1 no Efluente Geral para Atorvastatina e 37,1 μg L-1 no Efluente PA e 36,1 μg L-1 no Efluente Geral para Sinvastatina. Ozonização e eletrocoagulação foram aplicados na degradação/remoção das estatinas. As principais variáveis da eletrocoagulação foram investigadas utilizando a Metodologia de Superfície de Resposta através de um delineamento composto central. As taxas de degradação obtidas na ozonização foram de 100% para Atorvastatina, em 25 min de reação, para solução aquosa e efluente hospitalar; e 100% para Sinvastatina em 4 min em solução aquosa, e 10 min em efluente hospitalar. Já para a eletrocoagulação as taxas de remoção foram de 75,9% em solução aquosa e 70,9% em efluente hospitalar para Atorvastatina; e 100% para solução aquosa e afluente hospitalar para Sinvastatina, em 60 min de reação. A análise preliminar de risco ambiental revelou que as estatinas apresentam baixo risco ambiental, com PEC/PNEC < 1.
128

Avaliação das técnicas de microextração e eletroforese capilar em meio não aquoso (NACE) para determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica / Evaluation of microextractions techniques and nonaqueous capillary electrophoresis (NACE) for the determination of antidepressants in plasma samples for therapeutic drug monitoring

Ana Paula Formenton Catai 02 March 2012 (has links)
A monitorização terapêutica tem sido descrita como um recurso clínico valioso, na individualização do regime de dosagem, de acordo com a concentração do fármaco em amostras de plasma ou soro. O objetivo da monitorização terapêutica é assegurar a eficácia clínica e minimizar os efeitos adversos dos fármacos prescritos na clínica. A química analítica moderna tem sido direcionada para a simplificação dos métodos através da miniaturização dos sistemas analíticos, minimização do consumo de solvente orgânico e do volume da amostra. Neste contexto, metodologias analíticas utilizando as técnicas de microextração, extração sortiva em barra de agitação (SBSE) e microextração em sorvente empacotado (MEPS), juntamente com a eletroforese capilar em solução não-aquosa (NACE) foram desenvolvidas para fins monitorização terapêutica de antidepressivos inibidores seletivos da recaptação de serotonina (ISRSs: fluoxetina, sertralina, paroxetina e citalopram) em amostras de plasma de pacientes em terapia com ISRSs. Inicialmente foram padronizadas as condições eletroforéticas com detecção espectrofotométrica (UV) para análise simultânea dos ISRSs em amostras de plasma. Dentre as condições avaliadas (diferentes soluções de eletrólitos em meio aquoso e não aquoso, cromatografia eletrocinética micelar e NACE), a técnica NACE-UV foi a única que apresentou resolução dos fármacos adequada. Em seguida, otimizou-se as variáveis inerentes das técnicas de microextração (SBSE e MEPS), visando minimizar o tempo de análise e aumento da sensibilidade analítica. Para o método SBSE/NACE, as variáveis tempo e temperatura de extração, pH da amostra biológica e processo de dessorção foram otimizadas, já para o método MEPS/NACE, as variáveis, pH da amostra biológica, volume da amostra e número dos ciclos aspirar/dispensar foram otimizadas. A validação analítica foi realizada segundo as normas preconizadas pela Agência Nacional de Vigilância Sanitária (ANVISA), com adição de padrão de padrão interno às amostras de plasma enriquecidas com os antidepressivos em diferentes concentrações plasmáticas que contemplam o intervalo terapêutico dos ISRSs. Para avaliar a aplicabilidade das metodologias padronizadas, amostras de plasma de pacientes em terapia com os ISRSs foram analisadas. Os métodos padronizados (SBSE/NACE e MEPS/NACE) foram comparados ao método de referência (LLE/NACE), utilizando a extração líquido-líquido. As técnicas de microextração, quando comparadas à LLE, apresentaram as seguintes vantagens: a reutilização das fases extratoras, procedimentos de extração com reduzido número de etapas, menores volumes de amostras biológicas e de solventes orgânicos. Segundo os parâmetros de validação avaliados, os métodos SBSE/NACE e MEPS/NACE padronizados podem ser empregados nas análises dos antidepressivos (ISRSs) em amostras de plasma, para fins de monitorização terapêutica. / Therapeutic monitoring allows individualization of the dose regimen and has been indicated for the monitoring of well-established therapeutic intervals. In psychiatric disorders, most of the patients require that the plasmatic concentrations to be within a fixed range, so the disorders are kept under control and the adverse effects are acceptable. The aim of the therapeutic monitoring is ensure clinical effectiveness and minimization of adverse effects of drugs prescribed at the clinic. New trends in analytical chemistry have been directed towards simplification and miniaturization of analytical systems, and minimization of organic solvents and sample volume. In this work, analytical methodologies using microextraction techniques, such as stir bar sorptive extraction (SBSE) and microextraction by packed sorbent (MEPS), in conjunction with capillary electrophoresis in a nonaqueous background electrolyte (NACE) were developed for therapeutic drug monitoring of selective serotonin reuptake inhibitors (SSRIs: fluoxetine, sertraline, paroxetine and citalopram) in plasma sample of patients in therapy with SSRIs. First, the optimization of electrophoretic separation of the SSRIs was carried out to obtain simultaneous analysis of all antidepressants. Among the conditions evaluated (different background electrolytes in aqueous and nonaqueous medium, micellar electrokinetic capillary chromatography, and NACE), NACE-UV gave the best results. In the sequence, the optimization of the inherent variables of microextraction techniques (SBSE and MEPS)aiming analyses time minimization and increase of analytical sensibilitywas carried out. For SBSE/NACE methodology development the variables such as time of extraction, temperature of extraction, and matrix pH were optimized. For MEPS/NACE methodology the variables matrix pH and the volume of draw-eject cycles were optimized. Analytical validation was carried out in agreement with the norms of National Health Surveillance Agency (ANVISA) for both of the proposed methods, in different plasmatic concentrations, which completed the therapeutic interval. The developed methods (SBSE/NACE e MEPS/NACE) were compared to the reference method, using liquid-liquid extraction (LLE/NACE). Microextraction techniques, compared to LLE, gave the following advantages: reutilization of the extraction phase, fewer numbers of steps for extraction, reduction of sample volume, and less consumption of organic solvents. According to the evaluated validation parameters, the standardized methods SBSE/NACE and MEPS/NACE can be used in the analyses of antidepressants (SSRIs) in plasma sample for therapeutic drug monitoring purposes.
129

Desenvolvimento das barras imunosorventes de agitação e avaliação das técnicas extração sortiva em barra de agitação, microextração em sorvente empacotado e cromatografia líquida para análise de antidepressivos em amostras de plasma / Development of immunosorbent stir bars and evaluation of stir bar sorptive extraction, microextraction by packed sorbent and liquid chromatography for the analysis of antidepressants in plasma samples

Fernanda Zampieri Leandro 15 December 2010 (has links)
Neste trabalho, os anticorpos policlonais e monoclonais anti-fluoxetina foram produzidos em coelhos e camundongos, respectivamente, por imunização com o conjugado fluoxetina-soroalbumina bovina. Os anticorpos obtidos foram caracterizados em função da especificidade contra o fármaco por ELISA (enzyme linked immunosorbent assay) e posteriormente, purificados por afinidade em coluna fluoxetina-agarose labmade. Os anticorpos purificados foram imobilizados covalentemente na superfície vítrea das barras SBSE (extração sortiva em barra de agitação) labmade. Após a derivatização das barras com 3-aminopropiltrietoxisilano, dois métodos distintos de acoplamento dos anticorpos às barras SBSE foram avaliados: ativação com glutaraldeído e succinilação seguida de ativação via éster N-hidroxisuccinimida (NHS). A funcionalização das barras SBSE foi comprovada através da imobilização de enzima peroxidase (HRP) em lugar do anticorpo e posterior ensaio enzimático com as barras. Várias barras SBSE com diferentes áreas (1,2; 2,4; e 4,0 cm2) foram preparadas, dentre as quais, as com maior área imunosorvente apresentaram maiores taxas de recuperação do fármaco. A avaliação da morfologia da superfície da barra SBSE imunosorvente foi realizada através de Microscopia Eletrônica de Varredura (MEV). As variáveis do processo SBSE de imunoafinidade foram otimizadas para estabelecer o equilíbrio de sorção antígeno-anticorpo em um menor tempo de análise e obtenção de limite de quantificação compatível com o intervalo terapêutico do fármaco. As capacidades adsortivas das barras imunosorventes foram de 1,2 e 8 microgramas por cm2 para anticorpos policlonais e monoclonais, respectivamente. Os imunosorventes desenvolvidos apresentaram reatividade-cruzada apenas com norfluoxetina (metabólito ativo de fluoxetina). As barras imunosorventes foram reutilizadas aproximadamente 30 vezes, sem perda significativa da eficiência das extrações. Baseados nos parâmetros de validação analítica avaliados, os métodos de SBSE/LC-FD de imunoafinidade desenvolvidos são adequados para a determinação de fluoxetina em amostras de plasma de pacientes em terapia com o fármaco, para fins de monitorização terapêutica. Por conseguinte, esses métodos foram aplicados com êxito para análises de amostras de plasma de pacientes idosos em terapia com Prozac®. Neste trabalho, o método MEPS (microextração em sorvente empacotado)/LC-UV também foi desenvolvido e validado para análise simultânea de sertralina, paroxetina, citalopram, fluoxetina e mirtazapina em amostras de plasma para fins de monitorização terapêutica. As variáveis do processo MEPS foram otimizadas (pH e volume da amostra, força iônica, volume dos ciclos aspirar-dispensar e condições de dessorção) para estabelecer o equilíbrio de sorção em menor tempo de análise e obter sensibilidade analítica adequada para a determinação dos antidepressivos no intervalo terapêutico. O método MEPS/LC-UV desenvolvido permitiu integração da dessorção dos analitos e injeção da amostra no sistema cromatográfico (LC-UV) em uma única etapa, usando a microsseringa de extração MEPS. A fase extratora MEPS, M1 (C8/SCX), foi reutilizada mais de 50 vezes com perda mínima da eficiência da extração, comprovando a robustez do material sorvente. Segundo os parâmetros de validação analítica avaliados, o método MEPS/LC-UV desenvolvido é adequado para a determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica. / In this work, polyclonal and monoclonal anti-fluoxetine antibodies were developed in rabbits and mice by immunization with fluoxetine-bovine albumin conjugate, respectively. The developed antibodies were characterized on the basis of the specificity against the drug by ELISA (enzyme linked immunosorbent assay) and, subsequently they were purified by labmade fluoxetine-agarose affinity column. The purified antibodies were covalently immobilized onto the glass surface of labmade SBSE (stir bar sorptive extraction) bars. After derivatization of the bars with 3-aminopropyltriethoxysilane, two distinct methods were evaluated for the antibodies coupling to the SBSE bars: activation with glutaraldehyde and succinylation activation via ester N-hydroxysuccinimide (NHS). The functionalization of SBSE bars was confirmed by the immobilization of peroxidase (HRP) instead of the antibody and, subsequent enzymatic assay with the bars. Several SBSE bars with different areas (1.2, 2.4, and 4.0 cm2) were prepared, among of them the largest immunosorbent area showed higher recovery rates of the drug. The evaluation of surface morphology of the SBSE immunosorbent bar was performed using scanning electron microscopy (SEM). The SBSE immunoaffinity variables were optimized to establish sorption equilibrium of antigen-antibody in a short time analysis and to obtain the limit of quantification compatible with the therapeutic range of the drug. The adsorptive capacities of the immunosorbent bars were 1.2 and 8 micrograms per cm2 for polyclonal and monoclonal antibodies, respectively. The developed immunosorbents showed cross-reactivity only with norfluoxetine (active metabolite of fluoxetine). The immunosorbent bars were reused approximately 30 times without significant loss of the extraction efficiency. Based on evaluated analytical validation parameters, the developed immunoaffinity SBSE/LC-FD methods are suitable for the determination of fluoxetine in plasma samples from patients on therapy with the antidepressant for therapeutic drug monitoring. Therefore, these methods were successfully applied for the analysis of plasma samples from elderly patients undergoing therapy with Prozac®. In this work, the method MEPS (microextraction by packed sorbent)/ LC-UV was also developed and validated for the simultaneous analysis of sertraline, paroxetine, citalopram, fluoxetine and mirtazapine in plasma samples for therapeutic drug monitoring. The MEPS process variables were optimized (pH, sample volume, ionic strength, draw-eject cycles volume and desorption conditions) to establish the sorption equilibrium in a short time analysis and to obtain adequate analytical sensitivity for determination of antidepressants within therapeutic range. The developed MEPS/LC-UV method allowed integration of the analytes desorption and sample injection in the chromatographic system (LC-UV) in a single step, using a MEPS extraction microsyringe. The MEPS extraction phase, M1 (C8/SCX) was reused over 50 times with minimum loss of extraction efficiency, proving the robustness of the sorbent material. According to the evaluated analytical validation parameters, the developed MEPS/LC-UV method is suitable for the determination of antidepressants in plasma samples for therapeutic drug monitoring.
130

Desenvolvimento da fase extratora SPME de poli(pirrol) e avaliação das técnicas SPME/LC e SBSE/LC para análises de antidepressivos em amostras de plasma / Developmento of polypyrrole SPME extraction phase and evaluation of the SPME/LC and SBSE/LC techniques to antidepressants plasma samples analyses

Andréa Rodrigues Chaves 27 June 2008 (has links)
A depressão em idosos é uma desordem persistente e recorrente, resultado do stress psicossocial ou efeito de doenças fisiológicas, que podem acarretar a desabilidade do indivíduo, aumento dos sintomas das doenças clínicas, na maior utilização dos serviços de saúde e altas taxas de suicídios.A monitorização terapêutica permite a ndividualização do regime de dosagem, assegurando a eficácia clínica e minimizando os efeitos adversos dos fármacos, prescritos na clínica. Os antidepressivos têm sido monitorados, pois, apresentam intervalos terapêuticos bem estabelecidos, ou seja, a maioria dos pacientes, que apresentam concentrações plasmáticas dentro deste intervalo fixo, tem as desordens psiquiátricas mantidas sob controle e efeitos adversos aceitáveis. Os antidepressivos tricíclicos (ADTs): imipramina, amitriptilina, nortriptilina e desipramina, embora eficazes e ainda muito utilizados, apresentam efeitos adversos, não desejáveis. Os antidepressivos, inibidores seletivos da recaptação de serotonina (SSRIs): citalopram, fluoxetina, paroxetina e sertralina, apresentam eficácia clínica comparável aos clássicos ADTs, mas destituídos dos efeitos adversos associados aos mesmos. Os métodos convencionais, empregados no tratamento de amostras biológicas, para análises de antidepressivos por técnicas cromatográficas, têm sido a extração líquido-líquido e extração em fase sólida. A microextração em fase sólida tem sido empregada em diferentes análises em fluidos biológicos, porém essa técnica apresenta certas limitações como, o número limitado de fases extratoras disponíveis no comércio que sejam adequadas para a análise de compostos não iônicos. A avaliação de novas fases extratoras, mais seletivas, estáveis e de baixo custo tem sido requerida para a análise de fármacos. O interesse no uso de poli(pirrol) (PPY), como fase extratora para SPME, está relacionado às diferentes interações dos fármacos (hidrofóbicas, -, com o grupo funcional polar, troca iônica, ácido-base) aos grupos multifuncionais deste polímero. Sua polimerização pode ser alcançada tanto por oxidação química, quanto por eletrodeposição em meio aquoso ou orgânico. O método eletroquímico apresenta algumas vantagens, tais como: o polímero ou mistura de polimeros podem ser revestidos diretamente em um metal, incorporação de diferentes grupos funcionais, entre outras, a polimerização pode ser eletroquimicamente controlada através da voltametria cíclica. Neste trabalho o poli(pirrol) (PPY) foi eletrodepositado em eletrodo de aço inox e empregado para a microextração em fase sólida dos antidepressivos: paroxetina, fluoxetina, mirtazapina, duloxetina, sertralina e citalopram. As variáveis da eletrodeposição, número de ciclos e contra-íon empregado no processo de eletrodeposição foram otimizadas. Assim como as variáveis SPME: tempo, temperatura, pH e volume de amostra, e tempo e solvente de dessorção; almejando maior sensibilidade para o método SPME-PPY/LC UV proposto. A extração sortiva em barra de agitação (SBSE), técnica recente de preparo de amostras, para a pré-concentração de compostos orgânicos presentes em amostras biológicas, baseia-se na extração estática, através do polímero polidimetilsiloxano (PDMS), no qual ocorre a dissolução (sorção) do analito. Neste trabalho, as técnicas SBSE e cromatografia líquida de alta eficiência com detecção UV (SBSE/LC UV) foram avaliadas para a análise simultânea de antidepressivos em amostras de plasma para fins de monitorização terapêutica. As condições cromatográficas de análise, assim como as variáveis SBSE de extração (tempo, temperatura, força iônica, pH da matriz) e tempo de dessorção, foram otimizadas, visando adequada sensibilidade analítica. A validação analítica foi realizada segundo normas da ANVISA, para ambos os métodos propostos, em diferentes concentrações plasmáticas, as quais contemplam o intervalo terapêutico. Segundo os parâmetros de validação avaliados, os métodos SBSE/LCUV e SPMEPPY/LCUV padronizados poderão ser empregados nas análises dos antidepressivos, para fins de monitorização terapêutica. / Depression in the elderly is a persistent and recurrent disorder resulting from psychosocial stress or physiological effect or disease. This condition can lead to disability, cognitive impairment, enhanced symptoms of medical illnesses, increased use of health care services and, increased of suicide rates. Therapeutic monitoring allows individualization of the dose regimen, ensuring clinical effectiveness and minimizing the adverse effects of drugs, prescribed at the clinic. Antidepressants have been monitored because they present well - established therapeutic intervals; in other words, most of the patients present plasmatic concentrations within this fixed range, so that their psychiatric disorders are kept under control and the adverse effects are acceptable. The tricyclic antidepressants (ADTs) imipramine, amitriptyline, nortryptiline, and desipramine, have adverse effects. The selective serotonin reuptake inhibitors (SSRIs) antidepressants citalopram, fluoxetine, paroxetine, and sertraline, are clinically effectiveness as the classic ADTs, but they do not lead to the adverse effects associated to the latter. The conventional methods employed in the treatment of biological samples for analysis of antidepressants by chromatographic techniques have been the liquid-liquid extraction (LLE) and solid phase extraction (SPE) techniques. Solid-phase microextraction (SPME) has been used in various analyses of biological fluids. However, this technique has limitations such as the small number of comemercially available extracting phases that are appropriate for the analysis of non-ionic compounds. Investigation of new extraction phases that are more selective and stable, as well as inexpensive, has been requested for drug analysis. The interest in the use of poly(pirrole) (PPY) as an extraction phase for SPME is related to the different interactions of the drugs (hydrophobic, - , with the polar functional group, ionic exchange and acid-base) with the multifunctional groups on this polymer. The PPY polymerization can be achieved by chemical oxidation or electropolymerization in aqueous solution or organic solvents. The electrochemical method has advantages such as, the polymer or a mixes of polymers can be directly deposited on a metal wire, different functional groups can be incorporated, polymerization can be electrochemically controlled by cyclic voltammetry. In this work poly(pyrrole) was electropolymerized on stainless steel electrodes and employed for the solid phase microextraction of the antidepressants paroxetine, fluoxetine, mirtazapine, duloxetine, sertraline, and citalopram. The electropolymerization variables, the number of cycles and counterion employed in the process were optimized, as well as the SPME variables, time, temperature, pH, sample volume, and desorption solvent; aiming at a better sensibility for the proposed method SPME-PPY/LC-UV. The stir bar sorptive extraction (SBSE), recently established technique for samples preparation, that targets the pre concentration of organic compounds present in biological samples. It is based on static extraction, through the polymeric polydimethylsiloxane (PDMS), where there is analyte dissolution (sorption). In this work, the SBSE technique and liquid chromatography with UV detector (SBSE/LC-UV) were evaluated for the simultaneous determination of antidepressants in plasma samples for therapeutic monitoring purposes. The cromatographic conditions, the SBSE extraction variables (time, temperature, ionic strength and matrix pH), and the dessorption time were optimized for appropriate analytical sensibility. The analytical validation was accomplished according to the norms of ANVISA for both of the proposed methods, in different plasmatic concentrations, which contemplate the therapeutic interval. According to the evaluated validation parameters, the standardized methods SBSE/LC-UV and SPME-PPY/LC-UV can be used in the analyses of antidepressants for therapeutic drug monitoring purposes.

Page generated in 0.0769 seconds